EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Size: px
Start display at page:

Download "EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER"

Transcription

1 International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp , Article ID: IJMET_07_03_009 Available online at Journal Impact Factor (2016): (Calculated by GISI) ISSN Print: and ISSN Online: IAEME Publication EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER Abdulsalam D.Mohamed Mechanical Engineering, University of Waist Aamer M.Al-Dabagh Mechanical Engineering, University of Technology) Duaa A.Diab Mechanical Engineering, University of Waist ABSTRACT Heat pipe heat exchanger (HPHE) considers one of the most useful devices for the recovery of waste heat energy. An Experimental study has been carried out on air to air HPHE constructed of thermosyphon heat pipes with distilled water as the working fluid and a fill ratio of 75% from the evaporator length. Its model was composed of 4 rows, each row contains 12 copper tubes, each tube have ID= 9.5 mm, OD=10mm and length =950 mm and the rows of tubes were arranged in a staggered manner. Aluminum wavy plate fins of 0.1mm thickness were fixed among the tubes to increase the heat transfer area. Tests were conducted at various flow rates (air flow rate through evaporator and condenser sections) ranged between 0.12 and 0.37 kg/s and at different temperatures of air entering evaporator section (90, 100,110) to indicate discontinuity in the effectiveness when the flow rate ratio equal to one. The results show that the maximum value of effectiveness for the four heat pipe heat exchanger occurs when = 2. Theoretical model based on (ε- NTU) has been developed by using visual basic language computer program to analysis of the temperature distribution along heat pipe heat exchanger. The results from this model were compared with experimental results. A comparison between the experimental and theoretical results shows little discrepancy. Key words: Heat Pipe Heat Exchanger, Effectiveness, Mass Flow Rate Ratio, Temperature Distribution editor@iaeme.com

2 Experimental and Theortical Study of The Thermal Performance of Heat Pipe Heat Exchanger Cite this Article Abdulsalam D.Mohamed, Aamer M.Al-Dabagh and Duaa A.Diab, Experimental and Theortical Study of The Thermal Performance of Heat Pipe Heat Exchanger. International Journal of Mechanical Engineering and Technology, 7(3), 2016, pp GENERAL TERMS : Effectiveness, : actual heat transfer rate (w), : maximum heat transfer rate (w), : total overall heat transfer (w/m 2.k), : total area (m 2 ), : minimum heat capacity rate (kj/kg.k), : maximum heat transfer rate (kj/kg.k), : number of transfer unit, : effectiveness of evaporator, : number of transfer unit for evaporator, : effectiveness of condenser, : number of transfer unit for condenser, : overall heat transfer coefficient of evaporator (w/m 2.k), : heat transfer area of evaporator (m 2 ), :heat capacity rate of evaporator (w/k). : Overall heat transfer coefficient of condenser (w/m 2.k), : heat transfer area of condenser (m 2 ), : heat capacity rate of condenser (w/k), : area of pipe (m 2 ), : diameter of pipe(m), : length of pipe (m), : thickness of fin (m), : number of fins per meter, : number of pipes, :pi (=3.14), : width of fin (m), : total thermal resistance of evaporator (k/w), : external thermal resistance of evaporator (k/w), : fouling thermal resistance of (k/w), : wall thermal resistance of evaporator (k/w), : internal thermal resistance of evaporator, : total thermal resistance of condenser(k/w), : external thermal resistance of evaporator (k/w), : fouling thermal resistance of condenser (k/w), : wall thermal resistance of condenser (k/w), : internal thermal resistance of condenser, : overall effectiveness, j= number of row. 1. INTRODUCTION Heat pipe is a high performance heat transfer device which is used to transfer a large amount of heat at high rate with small temperature difference. This is achieved by evaporation of working fluid in the evaporator section and condensing in the condenser section and return of the condensate. If the wick is not used in the construction of heat pipe, it is called thermosyphon, in the thermosyphon return the working fluid from the condenser to evaporator is caused by gravity [1] Heat pipe is used in several utilizations like heat exchanger working as recovery system, solar energy communion system, cooling of electronic part, thermal control of space craft, gas turbine rotor blade cooling, etc [2]. The operating Limits of heat pipe include boiling limit, sonic limit, capillary limit, drag and viscous limit [3]. Thermosyphon Heat exchanger (THE) is one of the most productive devices for waste heat recovery. A thermosyphon heat exchanger is composed of a number of pipes arrayed in rows. It s operating with condenser section with low temperature fluid stream and evaporator section with high temperature fluid stream [4]. The advantages of Thermosyphon Heat Exchanger are Capable of operating even when temperature difference between heat source and heat sink is very low, less alimentation problems owing to containing no moving parts, large rate of effectiveness, No need any external power, Less pressure drop for fluid flow, Full disconnection of cold and hot fluids, Comparative economy and Large fidelity[5]. Zare et al. (2009) [6], studied the heat performance for air to water THE according to method. They used cold water with 0.1 kg/s flow through condenser editor@iaeme.com

3 Abdulsalam D.Mohamed, Aamer M.Al-Dabagh and Duaa A.Diab section and hot air in closed cycle was blown into evaporator section. The temperature range of From experimental results the effectiveness and heat transfer rate of THE were affected by heat capacity ratio for high and low temperature fluid streams.when the heat capacity ratio (Ce/Cc) of high and low temperature fluid streams was higher than unity the effectiveness increased due to ability of streams to release and absorb more heat. When the heat capacity ratio was equal to unity the effectiveness was minimum because the releasing and absorption heat was less. Danielewicz et al. (2014) [7], studied the effect of mass flow rate ratio between evaporator and condenser sections on the effectiveness of air to air THE according to method by using methanol as working fluid. The tested Heat exchanger consisted of ten rows and each row contained ten thermosyphons made of carbon steel while the fins were made from aluminum. They noticed that the effectiveness and heat transfer rate increased when the mass flow rate ratio ( increased. Vikramsinh and Mail (2015) [8], studied the thermal performance of THE for a lost air heat recovery system by using nanofluid with variable source temperature. The tested THE consisted of three rows arranged in staggered form. Each thermosyphon had inner diameter of mm and outer diameter of 15.88mm.The Experimental tests were carried out to determine the characteristics of THE by using nanofluid. They observed that the thermal performance of THE was enhanced by replacing the conventional fluid in thermosyphon with nanofluid. A model of a multi thermosyphon heat exchanger predicted the energy savings. 2. EXPERIMENTAL TEST RIG The heat pipe heat exchanger using thermosyphon was formed and constructed as shown in figure 1. This module is composed of 4 rows; each row has 12 copper tubes of 10 mm outside diameter. The rows of tubes were staggered and connected by aluminum wavy plate fins. The fin density was 470 fins per meter. A copper tube header of 22 mm nominal diameter was connected to the ends of each row of tubes. Distilled water is utilized as working fluid in thermosyphon heat exchanger. The fill ratio is chosen to be 75% from the volume of evaporator section. A duct and fan system used for testing the performance of thermosyphon heat exchanger, Table (1.1) indicate the specifications of this system Four air heaters of 3.5 Kw each are established inside the inlet duct of evaporator section at different temperatures. All heaters are connected directly to power supply except one is connected to variac (voltage transformer), in order to control the air stream temperature. Figure 1 Schematic of heat pipe heat exchanger editor@iaeme.com

4 Experimental and Theortical Study of The Thermal Performance of Heat Pipe Heat Exchanger Table 1.1 The specifications of duct and fan system: Cond. section Evap. section Name of section Length m) Area ( Inlet duct Type of fan Centrifugal fan (CFM) Air flow rate control type without Outlet duct Without Grill Inlet duct Centrifugal fan (CFM) without Outlet duct Without Grill 4. THEORY Formulas are dependent on developed (ε NTU) method, which is more convenient to indicate the temperatures distribution along thermosyphon heat exchanger and capable of comparing theoretical prediction and experimental results. (ε-ntu) a method depends on effectiveness of heat exchanger, (ε), which may be defined as ratio of actual heat transfer, to maximum rate of heat transfer; therefore, the effectiveness may be defined by Incropera [9]: Applying conservation of energy, general exponential function for a counter flow heat exchanger is represented by incropera [6]: The ratio is a dimensionless term called number of transfer unit which is defined as: For evaporator and condenser sections of heat pipe heat exchanger, their effectiveness can be determined respectively by the following equations: Where The heat transfer areas or for evaporator and condenser associated with one row of tubes for the evaporator and condenser can be calculated from the geometry of thermosyphon and fins as shown in Fig(2) editor@iaeme.com

5 Abdulsalam D.Mohamed, Aamer M.Al-Dabagh and Duaa A.Diab Or Where the area of the heat is pipe without fins and is the area of the fins. Figure 2 Schematic diagram of tubes and fins for one row evaporator or condenser The overall heat transfer coefficients of evaporator and condenser sections are required to calculate the NTU of the evaporator and condenser sections. Where An Effectiveness NTU relationship for the j th row can be evaluated for the evaporator and condenser. If, are given, then three equations can be written in convenient form for solution following Azad and Geoola [10]: For C c < C e ( the condenser air streams is the minimum fluid) editor@iaeme.com

6 Experimental and Theortical Study of The Thermal Performance of Heat Pipe Heat Exchanger For Ce < Cc (the evaporator air stream is the minimum fluid) 5. RESULTS AND DISSCUSSION To describe the discontinuity in effectiveness when mass flow rate ratio is equal one the tests were conducted. 1 In condenser section the flow rate is kept constant at minimum value (0. 132) kg/s while the flow rate in evaporator section is changed gradually from minimum value to maximum value. 2 In condenser section the flow rate is kept constant at maximum value (0. 132) kg/s while the flow rate in evaporator section is changed from minimum value to maximum value. Figures (3and4) and results are interesting for the selection of flow rate in heat recovery applications. If the processed fluid has a minimum flow rate, then higher effectiveness in heat recovery system could be achieved by using largest amount of exhaust gas flow. If the processed fluid has a higher flow rate, then the higher effectiveness in heat recovering system is achieved by using smaller exhaust gas flow rate. The right hand side curves (Fig 3) are obtained where the air stream in the condenser section is kept at low flow rate and air stream in evaporator section is editor@iaeme.com

7 Effectivness Effectivness Abdulsalam D.Mohamed, Aamer M.Al-Dabagh and Duaa A.Diab changing from low flow rate to high flow rate. The left hand side curves (Fig 4) are obtained where the air stream in the condenser section is kept at high flow rate and air stream in the evaporator section is changing from the low flow rate to high flow rate for condenser section. Discontinuity in the effectiveness when the flow rate ratio equal to one is shown clearly in (Fig5). For predicting the temperature distribution of air across evaporator and condenser sections of thermosyphon heat exchanger. A computer program written in visual basic language as employed to generate the theoretical conditions by using iterative processes. The main purpose of the program is to calculate inlet and outlet temperature for evaporator and condenser in each row of heat exchanger. The theoretical results obtained from the program were compared with experimental data. A comparison between predicted and measured temperatures in two air streams for thermosyphon heat exchanger subjected to different values of air flow rate ratio (1.31) and (0.45) at different temperatures are illustrated in Figures (6,7, 8,and9). Figures (7and9), illustrate that the difference between experimental and theoretical results for both evaporator and condenser sections increases with increase of the inlet temperature of air to evaporator section Mass flow rate ratio Figure 3 The effect of mass flow rate ratio on for a four heat pipe heat exchanger subjected to constant flow rate in the condenser section at kg/s and varying evaporator flow rate T=90 T=100 T=110 T=90 T=100 T= Mass flow rate ratio Figure 4 The effect of mass flow rate ratio on for a four row heat pipe heat exchanger subjected to constant flow rate in the condenser section at kg/s and varying evaporator flow rate editor@iaeme.com

8 Temperature (C) Temperature (C) Effectivness Experimental and Theortical Study of The Thermal Performance of Heat Pipe Heat Exchanger T=90 T=100 T= Mass flow rate ratio Figure 5 Discontinuity of the effectiveness at flow rate ratio equal one for a four row heat pipe heat exchanger Tc=Exp Tc=Theo Te=Exp Tc=Theo Row number,n Figure 6 Comparison of experimental and theoretical air temperature distribution for fourrow heat pipe heat exchanger at air flow rate ratio of 1.31 at inlet temperature= Tc=Exp Tc=Theo Te=Exp Te=Theo Row number,n Figure 7 Comparison of experimental and theoretical air Temperature distribution for fourrow heat pipe heat exchanger at air flow rate ratio of 1.31at inlet temperature=120 C editor@iaeme.com

9 Temperature (C) Temperature (C) Abdulsalam D.Mohamed, Aamer M.Al-Dabagh and Duaa A.Diab Tc=Exp Tc=Theo Te=Exp Te=Theo Row number,n Figure 8 Comparison of experimental and theoretical temperature distribution for four-row heat pipe heat exchanger at air flow rate ratio of 0.45 at inlet temperature =110 C Tc=Exp Tc=Theo Te=Exp Te=Theo Row number,n Figure 5.15 Comparison of experimental and theoretical temperature distribution for fourrow heat pipe heat exchanger at flow rate ratio of 0.45 at inlet temperature=120 C 6. CONCLUSION The maximum value of effectiveness for the four heat pipe heat exchanger occurs when = 2. From solving the mathematical model there is little discrepancy between theoretical and experimental results of temperature distribution of air along THE. The difference between theoretical and experimental results for evaporator section increases with increasing evaporator air inlet temperature. REFERNCES [1] Mohamed.S, Hossien.N, and Hassan.S, Application of Heat Pipe Heat Exchanger in Heating, Ventilation and Air Conditioning System, University of Minufiya, 6,PP (2011). [2] Peterson. G.P, an Introduction of Heat Pipes, Modeling, Testing and Applications, New York, p.245 (1994) [3] Faghri. A, Heat Pipe Science and Technology, Taylor and Francis (1995) editor@iaeme.com

10 Experimental and Theortical Study of The Thermal Performance of Heat Pipe Heat Exchanger [4] Noie. S. H, Energy Conservation by Waste Heat Recovery in Industry Using Thermosyphon Heat Exchanger, 28(136) 2004 [5] Preecha. K and Pipat.A, Two Phase Closed Thermosyphon and it Application for an Air to Air Heat Exchanger, The Journal of Kmutn, 22(1) 2012 [6] Zare. A, Ateshi.H, Noei.S.H, and Khoram.M, The Experimental and Theoretical Investigation on Thermal Performance of Gas-Liquid Thermosyphon Heat Exchanger in a Semi Industrial Plant, 6(3) 2009 [7] Danielewicz.J, Sayegh.M, Sinechowska.B, Szulgowska.M, and Jouhara.H, Experimental and Analytical Performance Investigation of Air to Air Two Phase Closed Thermosyphon Based Heat Exchanger, University of Wroclaw 2014 [8] Virkamsinh.H, Mail.K, Performance Investigation of Waste Recovery Heat Pipe Heat Exchanger by Using Nanofuid with Variable Source Temperature, ISSN , 4, PP 1-6 (2015). [9] Incropera.F.P, and Dewitt.D.P, Funddemental of Heat and Mass Transfer, John Wiley & Sons, New York, Seven Edition (2011). [10] Azad E, and Geoola.F. A, Design Procedure for Gravity assisted Heat Pipe Heat Exchanger, Heat Recovery System, 4(2), pp , 1984 [11] Ch. Sreenivasa Rao, Avssks Gupta and K. Rama Narasimha, Effect of Design Parameters on The Performance of A Closed Loop Pulsating Heat Pipe. International Journal of Mechanical Engineering and Technology, 4(3), 2013, pp [12] Ch. Sreenivasa Rao, Avssks Gupta and K. Ramanarasimha, Parametric Investigations on The Flow Characteristics of A Closed Loop Pulsating Heat Pipe - A Numerical Study. International Journal of Mechanical Engineering and Technology, 5(9), 2014, pp [13] Prof. Dr. Zena K. Kadhim and Hadi O. Mery. Free Convection From Optimum Sinusoidal Surface Exposed To Vertical Vibrations, International Journal of Mechanical Engineering and Technology, 7(1), 2016, pp editor@iaeme.com

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe 2011 International Conference on Communication Engineering and Networks IPCSIT vol.19 (2011) (2011) IACSIT Press, Singapore Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat

More information

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE Mr. Jaydev S. Bade 1, Dr. Nitin U. Korde 2 1 Student, Mechanical Engineering Department,

More information

Thermal Performance of a Loop Thermosyphon

Thermal Performance of a Loop Thermosyphon Tamkang Journal of Science and Engineering, Vol. 13, No. 3, pp. 281 288 (2010) 281 Thermal Performance of a Loop Thermosyphon Shung-Wen Kang*, Meng-Chang Tsai, Chih-Sheng Hsieh and Jian-You Chen Department

More information

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS International Journal of Mechanical Engineering and Technology (IJMET) Volume 10, Issue 01, January 2019, pp. 306 315, Article ID: IJMET_10_01_031 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=10&itype=1

More information

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid www.ierjournal.org International Engineering Research Journal (IERJ) Volume 1 Issue 6 Page 474-478, 215, ISSN 2395-1621 ISSN 2395-1621 Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid #1 Tushar

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental

More information

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 6340(Print), ISSN 0976 6340 (Print) ISSN 0976 6359

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,

More information

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Brig Gen Md. Lutfor Rahman, Sumaiya Nawrin, Rasel A Sultan Department of Mechanical Engineering, Military Institute

More information

American International Journal of Research in Science, Technology, Engineering & Mathematics

American International Journal of Research in Science, Technology, Engineering & Mathematics American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-358, ISSN (CD-ROM): 2328-3629

More information

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION 2597, Page 1 Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump Ian H. BELL 1 *, James E. BRAUN 2 1 Bell Thermal Consultants ian.h.bell@gmail.com 2 Purdue

More information

Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications

Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications 1 Jaydev S. Bade, 2 Nitin Korde, 3 Anurag Hatwar 1 ME Heat Power GHRCOEM, Ahmednagar 2 Department

More information

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector International Conference on Mechanical, Industrial and Materials Engineering 2015 (ICMIME2015) 11-13 December, 2015, RUET, Rajshahi, Bangladesh Paper ID: ET-46 Experimental Investigation of a Hybrid Evacuated

More information

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,

More information

ICMIEE Experimental Investigation of an Air to Air Heat Pipe Heat Exchanger for Moderate Temperature Waste Heat Recovery

ICMIEE Experimental Investigation of an Air to Air Heat Pipe Heat Exchanger for Moderate Temperature Waste Heat Recovery International Conference on Mechanical, Industrial and Energy Engineering 2018 23-24December, 2018, Khulna, BANGLADESH ICMIEE18-227 Experimental Investigation of an Air to Air Heat Pipe Heat Exchanger

More information

Investigation of Metal and Metal Oxide nanocoating on Fins in HPHE with Silver Water NanoFluid

Investigation of Metal and Metal Oxide nanocoating on Fins in HPHE with Silver Water NanoFluid American Journal of Mechanical Engineering, 2015, Vol. 3, No. 1, 21-25 Available online at http://pubs.sciepub.com/ajme/3/1/4 Science and Education Publishing DOI:10.12691/ajme-3-1-4 Investigation of Metal

More information

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT International Journal of Mechanical Engineering and Technology (IJMET) Volume 9, Issue 6, June 2018, pp. 242 247, Article ID: IJMET_09_06_028 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=9&itype=6

More information

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5 IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys

More information

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel

More information

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN International Journal of Mechanical and Production Engineering Research and Development (IJMPERD) ISSN 2249-6890 Vol. 3, Issue 2, Jun 2013, 137-146 TJPRC Pvt. Ltd. STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE

More information

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery

More information

STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER USING AL 2 O 3 MICROPARTICLES

STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER USING AL 2 O 3 MICROPARTICLES International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 4, July Aug 216, pp.189 195, Article ID: IJMET_7_4_19 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=4

More information

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS V. BHOGESWARA RAO Research Scholar Email:pallivayala@gmail.com Dr. S. CHAKRADHAR GOUD Principal, Sri Sarada Institute of Science and Technology

More information

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Anna Pacak 1,*, Andrzej Jedlikowski 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand

VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE Piyanun CHAROENSAWAN *1 and Pradit TERDTOON 2 *1 Department of Mechanical Engineering, Faculty of Engineering, Naresuan

More information

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation.

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation. Thermodynamic Analysis of Heat Pipe Using Ammonia, Water and Ethanol with a View to Being Used in Refrigeration Ankit Dwivedi, R. S. Mishra Department of Mechanical Engineering, Delhi Technological University,

More information

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Design and Development of Water Cooled Condenser for Domestic Refrigerator Design and Development of Water Cooled Condenser for Domestic Refrigerator Anil S. Patil Research PG Student, GF s Godavari College of Engineering, Jalgaon Dr. Atul A Patil Assot. Prof. GF s Godavari College

More information

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER Int. J. Mech. Eng. & Rob. Res. 2013 P Velmurugan and R Kalaivanan, 2013 Research Paper ISSN 2278 0149 www.ijmerr.com Vol. 2, No. 1, January 2013 2013 IJMERR. All Rights Reserved EFFECT OF DIVERSE STREAM

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review (JMSME) Print ISSN : 2339-9095; Online ISSN : 2393-9109; Volume 2, Number 6; April June, 2015 pp 80 84 Krishi Sanskriti Publications http://www.krishisanskriti.org/jmsme.html Natural Convection Heat Transfer

More information

HEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS

HEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 10, October 2017, pp. 180 184, Article ID: IJMET_08_10_022 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=10

More information

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE Proceedings of the Asian Conference on Thermal Sciences 2017, 1st ACTS March 26-30, 2017, Jeju Island, Korea ACTS-P00385 THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK

More information

EXPERIMENTAL INVESTIGATION ON SHELL AND TUBE HEAT EXCHANGER USING SEGMENTAL AND DISC-DOUGHNUT TYPE BAFFLES

EXPERIMENTAL INVESTIGATION ON SHELL AND TUBE HEAT EXCHANGER USING SEGMENTAL AND DISC-DOUGHNUT TYPE BAFFLES International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 12, December 2017, pp. 975 984, Article ID: IJMET_08_12_106 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=12

More information

Experimental Study of Fins Effect on Thermal Performance of HPHX for Air Conditioning System

Experimental Study of Fins Effect on Thermal Performance of HPHX for Air Conditioning System IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 15, Issue 4 Ver. III (Jul. - Aug. 2018), PP 70-78 www.iosrjournals.org Experimental Study of Fins

More information

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online): IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online): 2349-6010 Githin V Sam Jethin Babu Jesvin Sam Jithin Victor Abstract Loop heat pipes

More information

International Journal of Informative & Futuristic Research ISSN (Online):

International Journal of Informative & Futuristic Research ISSN (Online): Reviewed Paper Volume 2 Issue 9 May 2015 International Journal of Informative & Futuristic Research ISSN (Online): 2347-1697 Performance Comparison of R22 and R290 Refrigerants Using Smaller Paper ID IJIFR/

More information

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,

More information

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant Proceedings of the World Congress on Momentum, Heat and Mass Transfer (MHMT 16) Prague, Czech Republic April 4 5, 216 Paper No. ENFHT 111 DOI: 1.11159/enfht16.111 Experimental Investigation of a Multi

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE Ram Mohan Gupta 1, Dr. Shatyendra Singh 2 Mr. Simant Srivastava 3 1 Mechanical Engineering, Uttarakhand

More information

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature International Journal Of Computational Engineering Research (ijceronlinecom) Vol 3 Issue 3 Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

More information

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling

More information

SCIENCE CHINA Technological Sciences

SCIENCE CHINA Technological Sciences SCIENCE CHINA Technological Sciences RESEARCH PAPER May 2013 Vol.56 No.5: 1177 1185 doi: 10.1007/s11431-013-5204-7 Experimental investigations on the heat transfer characteristics of micro heat pipe array

More information

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack #1 Digvijay A. Shelar, #2 N.S. Gohel, #3 R. S. Jha #1 Mechanical Engineering Department,

More information

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV) Australian Journal of Basic and Applied Sciences, 5(7): 638-643, 2011 ISSN 1991-8178 Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves

More information

Mechanical Engineering Department Sheet (1)

Mechanical Engineering Department Sheet (1) Benha University Heat and Mass Transfer Faculty of Engineering at Shoubra 3 rd Year (Power) Mechanical Engineering Department Sheet (1) (1) What is heat exchanger? Mention with brief description and sketches

More information

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.329 341, Article ID: IJMET_07_03_030 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3

More information

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl

More information

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES Third Southern African Solar Energy Conference 11 13 May 2015 Kruger National Park, South Africa SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES Shahmohamadi M., Shafii, M.B.and

More information

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length HEIMO WALTER Institute for Thermodynamics and Energy Conversion Vienna University

More information

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance Study of Triple Concentric Pipe Heat Exchanger Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India

More information

VORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR

VORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR International Journal of Mechanical Engineering and Technology (IJMET) Volume 6, Issue 7, July 2015, pp. 97-102, Article ID: 30120150607012 Available online at http://www.iaeme.com/currentissue.asp?jtype=ijmet&vtype=6&itype=7

More information

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,

More information

Modelling the Performance of a Diffusion Absorption Refrigeration System

Modelling the Performance of a Diffusion Absorption Refrigeration System Modelling the Performance of a Diffusion Absorption Refrigeration System Noman Yousuf 1, Etienne Biteau 2, Timothy Anderson 1, Michael Gschwendtner 1 and Roy Nates 1 1 School of Engineering, Auckland University

More information

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12 EXPERIMENTAL ANALYSIS OF THE EFFECT OF FIN GEOMETRY ON HEAT TRANSFER RATE THROUGH THE REFRIGERATOR CONDENSER ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

More information

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2 Modern Applied Science; Vol. 9, No. 13; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education The Design of a Shell-Tube Heat Exchanger as Evaporator an Absorption

More information

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS Helan Jacob.J 1,Chandra Mohan.B 2,Palanisamy.S 3 1, P.G. Scholars, Department ofthermal Engineering, Oxford Engineering college,pratiyur, Trichy.

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK EXPERIMENTAL INVESTIGATION OF HELICAL COIL AND STRAIGHT TUBE HEAT EXCHANGER 1.

More information

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS International Journal of Design and Manufacturing Technology (IJDMT) Volume 6, Issue 2, July-December 2015, pp. 14-18, Article ID: 30320150602003 Available online at http://www.iaeme.com/currentissue.asp?jtype=ijdmt&vtype=6&itype=2

More information

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Ashraf A 1, Mohammed Shan N 2, Thoufeeq Azad 3, Bibin S4, Arun S 5 1-4 Students, 5 Assistant Professor Department of

More information

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters Performance of Water-in-Glass Evacuated Tube Solar Water Heaters I. and G.L.Morrison School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 AUSTRALIA E-mail: g.morrison@unsw.edu.au

More information

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant Bukke Bhagyalathamma 1, Dr.Smt.G.Prasanthi 2 Department 1,2,Department of Mechanical Engineering,PG Scholor

More information

Design, Manufacturing of Chilled Water System for Process Cooling Application

Design, Manufacturing of Chilled Water System for Process Cooling Application IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 11 May 2016 ISSN (online): 2349-784X Design, Manufacturing of Chilled Water System for Process Cooling Application Prof.

More information

2. HEAT EXCHANGERS MESA

2. HEAT EXCHANGERS MESA 1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and

More information

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING Journal of Marine Science and Technology, Vol. 18, No. 3, pp. 419-423 (2010) 419 FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING Chun-Sheng Yu*, Shung-Wen Kang*,

More information

Operation of a Two-Phase Reverse Loop Thermosyphon

Operation of a Two-Phase Reverse Loop Thermosyphon Journal of Applied Science and Engineering, Vol. 18, No. 3, pp. 259 264 (2015) DOI: 10.6180/jase.2015.18.3.06 Operation of a Two-Phase Reverse Loop Thermosyphon Meng-Chang Tsai 1, Shung-Wen Kang 2 *, Heng-Yi

More information

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance P Vamshi Krishna 1, Hemasunder Banka 2, S.Rama 3, Ch. Jeevan Reddy 4, G.Venkanna 5 1,2,3,4,5,

More information

Heat Transfer in Evacuated Tubular Solar Collectors

Heat Transfer in Evacuated Tubular Solar Collectors Heat Transfer in Evacuated Tubular Solar Collectors Graham L. Morrison, Indra Budihardjo and Masud Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 Australia

More information

Performance investigation of Air-conditioning system using ejector as expansion device

Performance investigation of Air-conditioning system using ejector as expansion device International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Performance

More information

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump Available online at www.sciencedirect.com Procedia Engineering 8 (2011) 165 170 2 nd International Science, Social-Science, Engineering and Energy Conference 2010: Engineering Science and Management Hot

More information

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Available online   Journal of Scientific and Engineering Research, 2018, 5(11): Research Article Available online www.jsaer.com, 2018, 5(11):152-157 Research Article ISSN: 2394-2630 CODEN(USA): JSERBR Evaporation Cooling with Ceramics in Air-conditioning System Attila Szilágyi 1, István Farkas 2,

More information

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(5):232-237 ISSN: 0976-8610 CODEN (USA): AASRFC Performance analysis of ejector refrigeration system with

More information

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72 International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins Piyush Kumar Kashyap 1, priyanka jhavar 2 1 sri satya sai, College of engineering& science, Sheore, 466001 Abstract: 2 sri satya

More information

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS 16th International Heat Pipe Conference (16th IHPC) Lyon, France, May 20-24, 2012 APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS Sandeep Kumar Singh, Sameer Khandekar

More information

Analysis of Effect of Varying Cross-Section on Thermal Efficiency of a Heat Pipe Heat Exchanger Using CFD

Analysis of Effect of Varying Cross-Section on Thermal Efficiency of a Heat Pipe Heat Exchanger Using CFD Analysis of Effect of Varying Cross-Section on Thermal Efficiency of a Heat Pipe Heat Exchanger Using CFD Junaid Ahmed 1, Prof. Animesh Singhai 2 1 Trinity Institute of Technology and Research, Research

More information

AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS

AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS Frontiers in Heat Pipes Available at www.thermalfluidscentral.org AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS K. S. Ong

More information

ENSC 388: Engineering Thermodynamics and Heat Transfer

ENSC 388: Engineering Thermodynamics and Heat Transfer ENSC 388: Engineering Thermodynamics and Heat Transfer Experiment 3: Free and Forced Convection Objective Determination of heat transfer coefficient for free and forced convection for different geometries.

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS Staņislavs GENDELIS, Andris JAKOVIČS Laboratory for mathematical modelling of environmental

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

Experimentation of Heat Pipe Used In Nano-Fluids

Experimentation of Heat Pipe Used In Nano-Fluids Experimentation of Heat Pipe Used In Nano-Fluids 1 Prashant Shinde, 2 Vinod Shinde, 3 Rajiv Talape, 4 D.N. Korade 1,2,3,4 Department of Mechanical Engineering, Sinhgad Institute of Technology & Science,

More information

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios To cite this article: S S Harikrishnan and

More information

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS - 1 - NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS S.J. Metcalf, Z. Tamainot-Telto (1) and R.E. Critoph School of Engineering, University of Warwick, Coventry CV4 7AL, UK Abstract: A new

More information

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a) International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a) Monika Tiwari 1, Dr.

More information

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES International Journal of Mechanical and Materials Engineering (IJMME), Vol. 2 (2007), No. 2, 109--117. EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES M. Hasanuzzaman

More information

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015 The Design of a Heat Exchanger Shell - Tube as Evaporator an Absorption Chiller Cycle to Reduce the Temperature of the Air Entering Diesel Engine Heavy Loads 75% And 50% of the Engine Part Seyyede Sepideh

More information

Falling Film Heat Exchangers for Solar Water Heaters

Falling Film Heat Exchangers for Solar Water Heaters Y.C., G.L. Morrison and M. Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 AUSTRALIA E-mail: yens@student.unsw.edu.au Abstract The characteristics of

More information

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS A. Hafner SINTEF Energy Research Refrigeration and Air Conditioning Trondheim (Norway) ABSTRACT The natural refrigerant carbon dioxide (CO 2 ) with all its

More information

CFD simulation and analysis of a gas to water two-phase closed thermosyphon-based heat exchanger

CFD simulation and analysis of a gas to water two-phase closed thermosyphon-based heat exchanger Advanced Computational Methods and Experiments in Heat Transfer XIII 217 CFD simulation and analysis of a gas to water two-phase closed thermosyphon-based heat exchanger J. B. Ramos 1, A. Z. Chong 1, C.

More information

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING ISSN (ONLINE): 2321-3051 INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING Heat Transfer Enhancement Techniques in Two Phase Closed Thermosyphon: A Review Faddas Nikhil A. 1,

More information

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Joint 18th IHPC and 12th IHPS, Jeju, Korea, June 12-16, 2016 Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Jens Weyant

More information