1 INSTALLATION INSTRUCTIONS ENERGY EFFICIENT FRESH AIR SYSTEM MODELS NRFLOH VSMARTH NRFLOE VSMARTE VB0113 RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER rev. D

2 ABOUT THIS MANUAL First, we want to congratulate you on your purchase of this excellent unit which will allow you and your family to enjoy clean and healthy air throughout your home for years to come! Please take note that this manual uses the following symbols to emphasize particular information: 0! WARNING Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death. CAUTION Denotes an instruction which, if not followed, may severely damage the unit and/or its components. NOTE: Indicates supplementary information needed to fully complete an instruction. ABOUT THESE UNITS 0! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING: 1. This unit is intented for residential installation only. 2. Installation must be done by qualified service personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances. 4. Do not install in a cooking area or connect directly to an appliance. 5. Before servicing or cleaning the unit, disconnect power from HVAC system. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities. 7. Do not use this unit with any solid-state speed control device. Use only with controller provided with the unit. 8. This unit must be installed in a weatherized location, out of direct sunlight and protected from the elements. 9. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 10. When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. 11. Servicing shall be done by qualified service personnel. CAUTION 1. For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Intended for residential installation only in accordance with the requirements of NFPA 90B and in compliance with all local and national codes that are applicable. 3. Be sure to duct air outside. Do not intake/exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage. 4. To avoid premature clogged filter, turn OFF the unit during construction or renovation. 5. Please read the unit specification label on the product for further information and requirements. 6. At least once a year, the unit mechanical and electronic parts should be inspected by qualified service personnel. 7. This unit must be connected to a 24-volt class 2 circuit only. NOTE: The fanless energy recovery ventilator NRFLOE or VSMARTE is designed to assist in the management of humidity introduced into the home. In extreme humidity conditions, the use of additional dehumidification may be desirable. Quickly remove all excess moisture and keep areas clean

3 TABLE OF CONTENTS 1. SERVICE PARTS DIMENSIONS SPECIFICATIONS TYPICAL INSTALLATION BEFORE STARTING INSPECT THE CONTENT OF THE BOX TOOLS AND MATERIALS LOCATING THE UNIT INSTALLATION CONFIGURATIONS INSTALL THE UNIT FRESH AIR SUPPLY PORT LOCATION BRACKETS INSTALLATION FRESH AIR SUPPLY PORT OPENING HANG THE UNIT CONNECTING THE DRAIN (NRFLOH AND VSMARTH UNITS ONLY) DUCTING INSTALLING NON-INSULATED DUCT CONNECTING THE INSULATED DUCTS TO THE UNIT INSTALL EXTERIOR HOOD(S) INSTALLING THE TANDEM TRANSITION KIT INSTALLING TWO EXTERIOR HOODS CONTROLLER INSTALLATION WIRING DIAGRAM AIR FLOW BALANCING CONTROLLER UNDERSTANDING CONTROLLER CHART OPERATING MODES PROGRAMMING CONTROLLER TROUBLESHOOTING WARRANTY APPENDIX A

4 1. SERVICE PARTS No. Description Part NRFLOH NRFLOE Number VSMARTH VSMARTE 1 Double collar port Damper actuator Damper kit Filter Thermistor kit* Controller* VL * PART NOT SHOWN. TO ORDER PARTS, CONTACT YOUR LOCAL DISTRIBUTOR. We have a phone line dedicated exclusively to installers. For assistance, call on weekdays, 8:00 a.m. to 5:00 p.m. (Eastern Standard Time). NOTE: Do not call these numbers for ordering parts! EXCLUSIVELY FOR NRFLOH AND NRFLOE UNITS: EXCLUSIVELY FOR VSMARTH AND VSMARTE UNITS: DIMENSIONS 12¼ ¼ 20¼ 6 Typ. VK0061A Motorized damper cable, 6 NOTE: Drain fittings on HRV units only. 3. SPECIFICATIONS MODELS NRFLOH NRFLOE VSMARTH VSMARTE WEIGHT 27 LB. 32 LB. PORT DIAMETER 6 6 DRAIN DIAMETER ½ N/A INSTALLATION BRACKETS (PROVIDED WITH THE UNIT) BRACKETS (PROVIDED WITH THE UNIT) ELECTRICAL SUPPLY 24 VOLTS, AC 24 VOLTS, AC POWER CONSUMPTION 5 VA 5 VA OUTSIDE TEMPERATURE DEFROST CYCLES (MINUTES) CELSIUS ( C) FAHRENHEIT ( F) DEFROSTING OPERATION TIME (BETWEEN EACH DEFROST CYCLE) -5 TO TO AND LESS -17 AND LESS

5 4. TYPICAL INSTALLATION The figure below illustrates a typical installation. In every case, the fresh air to building port of the unit must be connected to the return duct (plenum) of the furnace/air handler. The stale air from inside the duct must be connected to the supply duct of the furnace/air handler. All units are mounted to the forced air unit return duct using provided brackets. NOTE: For more details, see Point 7.4 in Section 7 INSTALL THE UNIT. In every case, a range hood should be used to exhaust stale air from a cooking area. A part of the stale air coming from the supply duct of the furnace/air handler is exhausted to the outside. Outside fresh air is supplied to the return duct of the furnace/air handler. See figure at right. NOTE: Home with multiple furnace/air handler systems should have 1 unit on each system. VH0064 All units can be installed in the attic. In this particular case, precautions must be followed: CAUTION 1. Due to the potential temperature difference between the attic and the rest of the house, all unit ducts must be insulated. 2. The attic temperature must always be above 0 C (32 F). 5. BEFORE STARTING 5.1 INSPECT THE CONTENT OF THE BOX 0! WARNING To avoid risk of suffocation, discard the plastic bag wrapping the unit s component. Inspect the exterior of the unit and components for shipping damages. Ensure that there is no damage to the ports, controller, etc. Inspect the interior of the unit for damages. Ensure that heat or energy recovery core, insulation, dampers, filter etc. are all intact. 5.2 TOOLS AND MATERIALS Here are the tools and materials needed to perform the installation: - Electric drill with Phillips bit no. 2 - Tin snips or metal shear - Cutter pliers - Long nose pliers - Utility knife (to cut duct tape and styrofoam) - Aluminum duct tape - 24-Volt class 2 transformer - 22-AWG 4-wire cable (any UL Listed (DUZX) Type CM or CMP for U.S. A., and CSA type CMG, FT-1 or FT-4 for Canada) - Jig saw - Caulking gun and caulking - 5 -

6 5. BEFORE STARTING (CONT D) 5.3 LOCATING THE UNIT Choose an appropriate location for the unit. Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from the unit. Close to a drain. If no drain is close by, use a pail to collect run-off (for NRFLOH and VSMARTH HRV units only). 6. INSTALLATION CONFIGURATION For more convenience, the unit fresh air supply port can be located on top or either at righ or left side of the unit. The illustrations below show 3 configuration types: SIDE CONFIGURATION A RETURN PARALLEL CONFIGURATION B RETURN PERPENDICULAR CONFIGURATION C RETURN VH0065A VH0066A VH0067A NOTES: 1.Side configuration (type A) applies either for right or left side port. 2.The unit can also be installed hung to the joist, or mounted to the wall. In these cases, the optional installation kit with port and chains must be used (part no ). 7. INSTALL THE UNIT 7.1 FRESH AIR SUPPLY PORT LOCATION Although the following shows how to prepare the opening on top of the unit, the procedure is the same for the ones located on sides of the unit. Using cutter pliers, remove the octogonal knock-out of the chosen opening. VR0011 CAUTION In order to prevent damages to the unit inner components, never use a blade longer than 5/8 to cut off the insulating foam. Insert the blade of a utility knife (5/8 long maximum) in the groove to cut off the insulating foam. Carefully remove the foam circle. 5/8 MAX. VR0012A - 6 -

7 7. INSTALL THE UNIT (CONT D) 7.1 FRESH AIR SUPPLY PORT LOCATION (CONT D) ALL CONFIGURATIONS (A, B AND C) Peel off the backing paper covering the sticky side of one of the included foam gasket and stick it over the fresh air supply port opening. PARALLEL AND PERPENDICULAR CONFIGURATIONS ONLY (B AND C) Peel off the backing paper covering the sticky side of the other included foam gasket and stick it upon the first foam gasket. VJ BRACKETS INSTALLATION STANDARD BRACKETS Three brackets are supplied with the unit; one hanger and two standard. See illustration beside. STANDARD BRACKETS HANGER BRACKET VR0014 According to the configuration chosen, install the standard brackets as follows: Configuration A (Side) needs one standard bracket installed below the unit, and the other one installed on top of unit, towards the same side of the fresh air supply port. Configuration B (Parallel) needs one standard bracket installed on the opposite side of the hanger bracket, and the other one is located near the fresh air supply port. Configuration C (Perpendicular) needs both standard brackets, installed on each side of the unit. See illustration below. A B C VR0017 HANGER BRACKET If parallel (B) or perpendicular (C) configuration is chosen, the hanger bracket must be modified. Using long nose pliers, bend the foldable part of the bracket at 90 towards its inner side. See illustration beside VR0015

8 7. INSTALL THE UNIT (CONT D) 7.2 BRACKETS INSTALLATION (CONT D) Install the included template corresponding to the chosen configuration on the furnace/air handler return duct. The minimum linear distance between the opening and the furnace/air handler unit return opening must comply with your local building code. According to your furnace/air handler ducts position, choose the most convenient configuration type. Using provided metal screws, mount the hanger bracket to the return duct, on the location shown on the template. In side configuration (A), install the unchanged hanger bracket. In parallel or perpendicular configuration, lean the folden part of the modified hanger bracket on the bottom edge of the return duct to ensure its proper location. See illustration beside. VR FRESH AIR SUPPLY PORT OPENING 0! WARNING When performing duct connections, always use approved tools and materials. Respect all corresponding laws and/or safety regulations. Please refer to your local building code. Using the template, trace a round opening on the furnace/air handler return duct. Cut out the round opening traced on the furnace/air handler return duct. VR HANG THE UNIT Remove the template from the duct and hang the unit to the hanger bracket. Then, use the provided screws and the standard bracket(s) mounted on the unit to secure it to the furnace/air handler return duct. VD0192 0! WARNING Using the adjustment slots on standard brackets, make sure the foam gasket seals completely the round duct opening. Then, permanently secure the standard brackets on unit using one screw in one center hole

9 8. CONNECTING THE DRAIN (NRFLOH AND VSMARTH UNITS ONLY) A 1. Insert the plastic tubing in the stale air from building port and punch out both drain holes, inside the unit. 2. Hand tighten the 2 plastic drain fittings (A) using the gaskets (B) and nuts (C) as shown. 3. Cut 2 sections of plastic tubing; about 12 (305 mm) long, and attach them to each drain fitting as shown. Join both short sections to the T junction and main tube as shown. 4.Make a water trap loop in the tube to prevent the unit from drawing unpleaseant odors from the drain source. Make sure this loop is located BELOW the T as shown. This will prevent water from being drawn back up into the unit in case of negative pressure. Run the tube to the floor drain or an alternative drain pipe or pail. Be sure there is a slight slope for the run-off VO0119 B C TIE WRAP TO DRAIN 9. DUCTING 9.1 INSTALLING NON-INSULATED DUCT Stale air exhaust duct SUPPLY RETURN Cut a 6 diameter opening into the furnace/air handler supply plenum. NOTE: If there is a A AC coil inside the supply plenum, the 6 diameter opening must be located between the A AC coil and the first branch of the supply plenum. Connect this opening with the stale air from building port. Use only metal duct. VJ0054A FIRST BRANCH FURNACE/AIR HANDLER SUPPLY PLENUM NOTE: If increased exhaust airflow is needed, a 90 elbow (scoop) should be installed in the supply plenum as pictured. A COIL 90 ELBOW VD

10 9. DUCTING (CONT D) 9.2 CONNECTING THE INSULATED DUCTS TO THE UNIT Use the following procedure for connecting the insulated flexible duct to the ports on the unit (exhaust to outside and fresh air from outside). a) Pull back the insulation to expose the flexible duct. b) Connect the interior flexible duct to the port using a duct tie. c) Carefully seal the connection with duct tape. d) Pull the insulation over the joint and tuck it between the inner and outer rings of the double collar. e) Pull the vapor barrier over the insulation and over the outer ring of the double collar. f) Apply duct tape to the joint making an airtight seal. Avoid compressing the insulation when you pull the tape tightly around the joint. Compressed insulation loses its R value and causes water dripping due to condensation on the exterior surface of the duct. CAUTION Make sure that the vapor barrier on the insulated ducts does not tear during installation to avoid condensation within the duct. a) b) c) d), e) f) VJ INSTALL EXTERIOR HOOD(S) 10.1 INSTALLING THE TANDEM TRANSITION* KIT The joist opening needed to install the Tandem transition must be 9¾ minimum. The maximum height of the Tandem transition is 8¾. To connect the insulated flexible ducts to the Tandem transition (Exhaust air to outside and Fresh air from outside), follow the instructions included with the Tandem transition kit (part #14690). *Patent Pending. VR0003 Tandem transition kit NOTE: If the joists are perpendicular to the ducts, or if the connection to the exterior hood is in a limited area, the installation will need 2 exterior hoods instead of one. See next Section 10.2 INSTALLING 2 EXTERIOR HOODS

11 10. INSTALL EXTERIOR HOOD(S) (CONT D) 10.2 INSTALLING 2 EXTERIOR HOODS Choose an appropriate location to install the exterior hoods: There must be a minimum distance of 6 feet (1.8 m) between the hoods to avoid cross-contamination. There must be a minimum distance of 18 inches (457 mm) from the ground. Make sure the intake hood is at least 6 feet (1.8 m) away from the following: Dryer exhaust, high efficiency furnace vent, central vacuum vent Gas meter exhaust, gas barbecue grill Any exhaust from a combustion source Garbage bin and any other sources of contamination Refer to figure below for connecting insulated ducts to the exterior hoods. An Anti-gust intake hood should be installed in regions where a lot of snow is expected to fall. EXHAUST HOOD 6 Ø (152 MM) INTAKE HOOD 18 (457 MM) 6 (1.8 M) 18 (457 MM) 6 (1.8 M) OPTIONAL DUCT LOCATION 18 (457 MM) TAPE AND DUCT TIE VD

12 CONTROLLER INSTALLATION 0! WARNING Always disconnect the furnace/air handler before making any connections. Failure in disconnecting power could result in electrical shock or damage of the wall control or electronic module inside the furnace/air handler. 1. Determine the more convenient location for the controller. It can be located up to 6 feet from the ventilation unit. 2. Remove the cover plate controller. 3. Connect the unit cable connector to J4 connector on controller electronic board. VE Perform the electric connection between J1 and J3 connectors on controller electronic board and thermostat terminal and furnace/air handler. Refer to picture and figure below or to the wiring diagram on next page. J1 CONNECTOR J3 CONNECTOR THERMOSTAT TERMINAL W R G Y ENERFLO UNIT TERMINALS W R G C Y J1 GT G R J3 N 24 NOTE If air handler transformer is not powerful enough, connect J3 connector to an additional 24 V AC Class 2 transformer. FURNACE/AIR HANDLER 24 VOLTS VE0152A TERMINAL COOLING SYSTEM VE

13 12. WIRING DIAGRAM 0! WARNING Always disconnect the furnace/air handler before making any connections. Failure in disconnecting power could result in electrical shock or damage of the wall controller or electronic module inside the furnace/air handler. t o R1 Outdoor temperature sensor A2 EXT FOUR 1 2 J1 J DAMPER ELECTRONIC ASSEMBLY G FROM THERMOSTAT G TO AIR HANDLER R FROM AIR HANDLER R FROM AIR HANDLER C FROM AIR HANDLER NOTE 3 t o RED BLU GRN BRN YEL ORA R Air handler supply temperature sensor J4 GT G R J1 N 24V J J J6 CFM MEAS CFM % CODE PVENT DS2 DS3 DS4 DS5 DS1 S1 JP1 S2 YELLOW RED GREEN BLACK M1 Damper motor 24VAC / 60Hz A1 ELECTRONIC ASSEMBLY COLOR CODE NOTES BLACK 1. If any of the original wire, as supplied, must be BLU BLUE replaced, use the same equivalent wire. BRN BROWN 2. Field wiring must comply with applicable codes, GRN GREEN ordinances and regulations. ORA ORANGE 3. If air handler transformer is not powerful enough, RED RED use an additional 24 V AC Class 2 transformer. YEL YELLOW LOGIC DIAGRAM G FROM THERMOSTAT G TO AIR HANDLER R FROM AIR HANDLER J1 GT G R K3 J1 R FROM AIR HANDLER C FROM AIR HANDLER NOTE 3 J3 N 24V t o R1 Outdoor temperature sensor EXT FOUR 1 2 J RED BLU GRN BRN YEL ORA t o R Air handler supply temperature sensor J CPU K2 K3 12VDC K2 A2 DAMPER ELECTRONIC ASSEMBLY M1 A1 ELECTRONIC ASSEMBLY VE0151A Damper motor 24VAC / 60Hz

14 13. AIR FLOW BALANCING Balance the unit according to local code requirements. If desired, refer to Appendix A ESTIMATED AIRFLOW DEPENDING OF INSTALLATION AND AVAILABLE STATIC PRESSURES IN THE FURNACE DUCTING on page 18. What you Need to Balance the Unit A magnehelic gauge capable of measuring 0 to 0.5 inches water gauge (0 to 125 Pa) and 2 plastic tubes. Two flow collars. Preliminary Stages for Balancing the Unit Close all windows and doors. Turn off all exhaust devices such as: range hoods, dryers and bathroom fans. VP0005 flow collar Installation of Flow Collars B Insert the flow collars in the insulated ducts as follows: On the fresh air from outside duct (first measuring location, A) On the exhaust air duct (second measuring location, B) Make sure their arrows are pointing in the direction of the airflow. Tape collars in place temporarily. Balancing Procedure VJ0056 A S2 1. On controller board, jump BLACK and GREEN terminals. YELLOW RED GREEN BLACK 2 Turn the furnace/air handler blower ON. Wait until booting sequence is done. VE Place the magnehelic gauge on a level surface and adjust it to zero. 4. Connect tubing from gauge to flow collar in fresh air stream (location A above). Be sure to connect the tubes to their appropriate high/low fitting. If the gauge reading drops below zero, reverse the tubing connections. Hold or place the magnehelic gauge upright and level. Record the reading. LOW HIGH FLOW VP Move tubing to the other flow collar (location B above) and note reading. Adjust an exhaust air balancing damper (field supplied) until the reading at B is approximately the same as the reading at A. If the reading at B is less than the reading at A, then go back and adjust the fresh air balancing damper (field supplied) to equal the exhaust air flow. 6. Remove flow collars and reconnect the duct, then seal with aluminum duct tape. Write the required airflow information on a label and stick it near the unit for future reference: (date, maximum speed airflows, your name and phone number and business address). LOW HIGH FLOW 7. Remove jumper between BLACK and GREEN terminals. NOTES: Most flow collar kits provide a conversion chart situated on the collar which enables you to convert magnehelic gauge readings to equivalent cfm values. A difference of ± 10 cfm ( ± inches water gauge) between the 2 readings is considered balanced VP0004

15 14. CONTROLLER Remove the controller cover to access its electronic board UNDERSTANDING CONTROLLER CHART In the upper right section of the controller board, there is a chart beside a scaled LED indicator (DS1). See beside. This chart shows the preset values available to program the controller. First column is for the CFM measured on exhaust air to outside duct, when balancing the unit (see previous Section Air Flow Balancing). Second column is for the CFM allowed according to your local building code. Third column is the percentage of air exchange, during a 60-minute cycle. For example, a 10% value means the unit exchanges air with the outside during 6 minutes every hour. There is a LED below each column. Beside the chart is a scaled LED indicator (DS1). Starting from the bottom, the LEDs light up to indicate which value has been chosen on the chart OPERATING MODE CFM MEAS CFM % CODE PVENT DS2 DS3 DS4 DS5 DS1 S1 S2 button controls the operating modes. Refer to table below for choosing operating mode. NOTE: When activating the controller for the first time, S1 lights up RED for approximately 20 seconds to indicate the controller is booting. Once booting is done, S1 shuts off. VE0154 S2 PRESSING ON S2 BUTTON DS5 LED COLOR RESULTS ONCE GREEN UNIT IS RUNNING IN PERCENTAGE VENTILATION MODE. THIS MODE ALLOWS THE UNIT TO (PERCENTAGE VENTILATION MODE) EXCHANGE WITH THE OUTSIDE AS LONG AS THE PERCENTAGE VALUE ENTERED WHEN PROGRAMMING THE CONTROLLER, ON A 60-MINUTE CYCLE. FOR EXAMPLE, IF THE VALUE ENTERED WAS 20, THIS MEANS THE UNIT WILL EXCHANGE WITH THE OUTSIDE DURING 12 MINUTES ON A 60-MINUTE CYCLE (20% OF 60 MINUTES). TWICE YELLOW UNIT IS RUNNING IN CODE COMPLIANCE MODE. THIS MEANS THE UNIT TAKES IN (CODE COMPLIANCE MODE) ACCOUNT THE CFM MEASURED VALUE WITH THE CFM CODE VALUE ENTERED TO DETERMINE HOW LONG THE UNIT WILL EXCHANGE WITH THE OUTSIDE DURING A 60-MINUTE CYCLE. SEE EXAMPLES BELOW. THREE TIMES SHUTS OFF UNIT IS OFF. CODE COMPLIANCE MODE EXAMPLES: Example 1: CFM Code value entered: 70 CFM = 78% The unit will be exchanging with the outside during 47 minutes CFM Measured value entered: 90 CFM on a 60-minute cycle. Example 2: CFM Code value entered: 100 CFM = 200% Since this value exceed the 100% maximum value, the unit CFM Measured value entered: 50 CFM will be exchanging with the outside during 60 minutes on a 60-minute cycle

16 14. CONTROLLER (CONT D) 14.3 PROGRAMMING CONTROLLER NOTE: The controller is factory set to the following values: CFM measured: 90, CFM code: 70 and % PVENT: 30%. A. PROGRAMMING CFM MEAS 1 Press S1 for 3 seconds to start programming. The LED under the CFM measured column ligths up. 2 Press on S2 to enter the CFM measured value corresponding to the one measured on exhaust to outside duct. On example beside, the LED under the CFM measured column is lit, and the second and third LED of DS1 are also lit. This means the CFM measured value entered is 70 CFM. NOTE: If the value to be entered has been 60, only the second LED would have been lit, and for a 80-CFM value, it would have been only the third one. For the in-between values, 2 LEDs must be lit. B. PROGRAMMING CFM CODE 1 Press on S1 to access to the second column; the LED under the second column will light up while the one under the first one will turn off. 2 Press on S2 to enter your CFM code value. Use the DS1 LEDs to see the value entered. C. PROGRAMMING % PVENT CFM MEAS VE0155 CFM CODE % PVENT DS1 S1 1 Press on S1 to access the third column; the LED under the second column will turn off while the one under the third column will light up. 2 Press on S2 to enter your % PVENT value. Use the DS1 LEDs to see the value entered. Once programming is done, press on S1 for 3 seconds to record the settings. NOTE: A power failure doesn t affect the controller settings. When the power is back, after the booting sequence, the controller returns to its previous setting. Reinstall the controller cover. 15. TROUBLESHOOTING When DS5 LED flashes RED and DS2, DS3 or DS4 LED is flashing on the controller, this means the unit sensors detected a problem. Refer to the table below to know where on the unit the problem occurs. DS2 LED flashes with DS5 LED Damper actuator error. Replace the damper actuator. DS3 LED flashes with DS5 LED Exterior thermistor error. Replace the exterior thermistor. DS4 LED flashes with DS5 LED Internal thermistor error. Replace the internal thermistor

17 16. WARRANTY WARRANTY Venmar Ventilation inc. or vänee Canada warrants to the original purchaser of its products that such products will be guaranteed against all manufacturing defects and defective material for a period of two (2) years from the date of original purchase. The heat recovery core is protected by a limited lifetime warranty and the energy recovery core is protected by a 5-year warranty. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VENMAR VENTILATION INC. OR VÄNEE CANADA WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A UNIT, NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT. During the period stated above, Venmar Ventilation inc. or vänee Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover a) normal maintenance and service, b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by other than Venmar Ventilation inc. or vänee Canada, or c) a faulty installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the 2-year period as specified for the express warranty. Somes States or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. VENMAR VENTILATION INC OR VÄNEE CANADA S OBLIGATION TO REPAIR OR REPLACE, AT VENMAR OR VÄNEE S OPTION, SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR OR VÄNEE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PROD- UCT USE OR PERFORMANCE. SOME STATES OR PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. This warranty gives you specific legal rights and you may also have other rights, which vary from State or province to another. This warranty supersedes all prior warranties. To contact Venmar Ventilation inc. or vänee Canada warranty service, call (Canada and United States). In order to qualify for a warranty claim, the owner of a unit must have the model and serial number along with a proof of the original purchase date. At the time of requesting service, describe the nature of any defect in the product or part. In case of discrepancies between the English and the French versions of the warranty, the English version will prevail

18 APPENDIX A ESTIMATED AIRFLOW DEPENDING OF INSTALLATION AND AVAILABLE STATIC PRESSURES IN THE FURNACE DUCTING

INSTALLATION GUIDE VB0180 VB0148

INSTALLATION GUIDE VB0180 VB0148 INSTALLATION GUIDE VENMAR AVS VÄNEE VB0179 VB0180 VB0177 VB0178 Kubix ERV (side ports) Model no. 44113 Kubix ERV (top ports) Model no. 44112 Vïgor ERV (side ports) Model no. 44213 Vïgor ERV (top ports)

More information

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE VB0190 Model ERV70S (side ports) VB0192 Model ERV70T (top ports) VB0191 Model HRV70SE* (side ports) VB0193 Model HRV70TE* (top ports) * These products earned the ENERGY STAR by meeting

More information

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE VB0195 MODELS H50100H AND H50100E These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. They meet ENERGY

More information

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV Model no.: 41502 (HRV with ports on top) Model no.: 41500 (HRV with ports on sides) VB0069 VB0070 Model no.: 41506 (ERV

More information

INSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

INSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS INSTALLER MANUAL VB0234 HRV150FL (part HRV150FLS) HRV190FL (part HRV190FLS) RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 REGISTER

More information

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0 INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO.5* AND CONSTRUCTO.0 VB056 RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS *This product earned the ENERGY STAR by meeting strict energy efficiey guidelines

More information

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE Installation Manual FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE VB0021 10/2004 04435 Table of contents 1.0 Sizing.............................................................3

More information

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS INSTALLATION GUIDE FOR AVS HRV EKO.5, AVS CONSTRUCTO.5V, HRV 90H-V ECM AND 90H-V UNITS THIS UNIT HAS A SPECIAL START-UP PROCEDURE, REFER TO PAGE. V09 THIS UNIT HAS A SPECIAL START-UP PROCEDURE, REFER TO

More information

Installation Instructions

Installation Instructions HRVCRSVU57 Heat Recovery Ventilator Installation Instructions HRVCRSVU57 A89 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment,

More information

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will

More information

INSTALLATION GUIDE VÄNEE HRV 60H AND ERV 60H

INSTALLATION GUIDE VÄNEE HRV 60H AND ERV 60H INSTALLATION GUIDE VÄNEE HRV 60H AND ERV 60H Model no.: 41602 (HRV with ports on top) Model no.: 41600 (HRV with ports on sides) VB0072 VB0076 Model no.: 41606 (ERV with ports on top) Model no.: 41604

More information

INSTALLATION INSTRUCTIONS AND USER MANUAL

INSTALLATION INSTRUCTIONS AND USER MANUAL INSTALLATION INSTRUCTIONS AND USER MANUAL MODELS HRV 2600* HR 2.6* HEPA 3100* HF 3.1* HEPA 4100* VB0064 NOTES: 1. HRV 2600* model is available in Canada only. 2. HEPA 4100* model is available in United

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS ULTRA SILENT TM VENTILATION FAN Page 1 READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner

More information

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION! Register ULTRA SILENT your product online at VENTILATION FAN www.broan.ca READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

More information

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination Bathroom Exhaust Fan/Fluorescent Light Combination MODEL: 8663RF Suitable for use in shower or tub enclosure when used with GFCI protected branch circuit. The exhaust fan consists of the housing, power

More information

Novofit 2.0 (Part no )

Novofit 2.0 (Part no ) INSTALLER MANUAL VENTILATION SYSTEMS FOR RESIDENTIAL USE ONLY VB0157 Novofit 1.5* (Part no. 43121) Novofit 2.0 (Part no. 45121) *This product earned the ENERGY STAR by meeting strict energy efficiency

More information

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion AUTOMATIC MAKE-UP AIR DAMPER WITH To register this product visit: www.broan.com MODELS MD6T MD8T MD10T READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE,

More information

INSTALLER AND USER MANUAL VENTILATION SYSTEM

INSTALLER AND USER MANUAL VENTILATION SYSTEM INSTALLER AND USER MANUAL VENTILATION SYSTEM VB0230 HRV Solo 2.4 & ERV Quattro 2.4 READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL TO THE HOMEOWNER 22068 rev. 01 ABOUT THIS MANUAL This manual

More information

INSTALLATION INSTRUCTIONS AND USER MANUAL

INSTALLATION INSTRUCTIONS AND USER MANUAL INSTALLATION INSTRUCTIONS AND USER MANUAL MODELS HEPA 3.2* and THH.0* VB0049 VB0058 *Patents pending NOTE: HEPA 3.2 model available in Canada only. For United States, use Venmar HEPA 000 model. RESIDENTIAL

More information

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination Bathroom Exhaust Fan/Fluorescent Light Combination MODEL: 769RF IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this

More information

INSTALLATION INSTRUCTIONS MANUAL

INSTALLATION INSTRUCTIONS MANUAL INSTALLATION INSTRUCTIONS MANUAL HEPA Filtration and Fresh Air Ventilation* GSVH1K VB0061 *Patents pending HEPA Filtration* GSFH1K HEPA Filtration, Fresh Air and Energy Recovery Ventilation* GSEH3K RESIDENTIAL

More information

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS USER GUIDE VB0110 BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS *This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US

More information

INSTALLATION INSTRUCTIONS AND USER GUIDE

INSTALLATION INSTRUCTIONS AND USER GUIDE INSTALLATION INSTRUCTIONS AND USER GUIDE VENMAR MODELS BROAN MODELS VB0186 EVO5 700 HRV HEPA VB0068 HRV 7.1 HEPA VB0187 EVO5 500 HRV VB0067 HRV 5.1 * These products earned the ENERGY STAR by meeting strict

More information

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner. Register your product online at www.broan.ca/register.asp. ZB90C ZB0C X Multi-Speed Ventilation Fan INSTALLATION GUIDE Easy

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev. USER GUIDE VB0100 MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS 07919 rev. B About this Guide This guide uses the following symbols

More information

breeze easytm model # F100-1W

breeze easytm model # F100-1W DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS ROOF-MOUNT POWE ATTIC VENTILATOR Page 1 READ AND SAVE THESE INSTRUCTIONS WARNING TO UCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner

More information

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location

More information

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual FILTER COVER VENTILATION CONTROLLER INLET COLLAR OUTLET COLLAR SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury

More information

Please Read and Save These Instructions Safety Information

Please Read and Save These Instructions Safety Information The learning fan TM Please Read and Save These Instructions Safety Information 1.) WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS User Manual READ AND SAVE THESE INSTRUCTIONS VB0140 vänee 2000 HE 3000 HE VENMAR 1.8 HE 2.6 HE These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources

More information

Installation Instructions

Installation Instructions HRVXXLHB Heat Recovery Ventilator Installation Instructions HRVXXLHB Unit These products earned the ENERGY STAR by meeting strict energy efficiey guidelines set by Natural Resources Canada and the US EPA.

More information

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8142 FRESH AIR ILATOR MODEL 8142NC FRESH AIR ILATOR OUTLET COLLAR MOUNTING BRACKET ILATION CONTROLLER OUTLET COLLAR

More information

CVS Model Inline Multi-Port Ventilators

CVS Model Inline Multi-Port Ventilators Installation Manual Item #: 402332 Rev Date: 081613 CVS Model Inline Multi-Port Ventilators United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada 50 Kanalflakt

More information

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV USER GUIDE HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV PLEASE READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC,

More information

Installation Instructions

Installation Instructions ERVCRLHB Energy Recovery Ventilator HRVCRLHB Heat Recovery Ventilator Installation Instructions ERV/HRV Unit A0560 INTRODUCTION The Energy/Heat Recovery Ventilator (ERV/HRV) is used to exchange indoor

More information

Easy installation in both new construction and retrofit

Easy installation in both new construction and retrofit READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner. Register your product online at www.broan.com/register. XB50L XB80L XB0L X Single-Speed Ventilation Fan with Light and Night

More information

Bathroom Exhaust Fan

Bathroom Exhaust Fan Bathroom Exhaust Fan Models: Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in accordance with CEC, NEC and local

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information

USER MANUAL HRV150S* HRV190S* AND ERV180S READ AND SAVE THESE INSTRUCTIONS

USER MANUAL HRV150S* HRV190S* AND ERV180S READ AND SAVE THESE INSTRUCTIONS USER MANUAL RESIDENTIAL USE ONLY VB0234 HRV150S* HRV190S* AND ERV180S * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA AND THE US EPA.

More information

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8140 FRESH AIR ILATOR MODEL 8140NC FRESH AIR ILATOR FILTER COVER ILATION CONTROLLER FILTER COVER ILATION TERMINALS

More information

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED TABLE OF CONTENTS Package Contents Important Instructions Preparation Assembly Instructions Wiring Instructions Operating Instructions Care and

More information

VIGÖR HRV PLUS AND VIGÖR ERV

VIGÖR HRV PLUS AND VIGÖR ERV User Guide VIGÖR HRV PLUS AND VIGÖR ERV VB0147 Model no. 44202 (with top ports) VB0149 Model no. 44212 (with top ports) VB0148 Model no. 44203 (with side ports) VB0150 Model no. 44213 (with side ports)

More information

Installation Instructions

Installation Instructions Installation Instructions 30" ELECTRIC Downdraft Cooktop Modules selected at time of purchase IMPORTANT: Read and save these instructions. Part No. 208040 A 438589 Quick Reference Table of Contents: Pages

More information

Easy installation in both new construction and retrofit

Easy installation in both new construction and retrofit READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner. Register your product online at www.broan.ca/register. RB80LC RB0LC ULTRA Pro TM Ventilation Fan / Light / Night Light with

More information

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS Suncourt recommends professional installation of the Airiva (or by an accomplished DIY person) Please read and save these entire instructions before starting

More information

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual. VENTILATORS MODELS: VH30100 30-100 CFM HRV VE30100 30-100 CFM ERV Features Three operating modes (Intermittent, Continuous and High) 100% variable speed Quick-connect duct collar system Proportional defrost

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! BROAN-NUTONE LLC; HARTFORD, WISCONSIN WWW.NUTONE.COM 1-888-336-3948 REGISTER YOUR PRODUCT ONLINE

More information

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1. User Guide HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.5 VB0122 VB0123 VB0126 VB0136 PLEASE READ AND SAVE THESE

More information

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V User Guide HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+ VB0124 VB0125 VB0127 PLEASE READ AND SAVE THESE INSTRUCTIONS. These products earned the ENERGY STAR by meeting strict energy

More information

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV) Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured

More information

INSTALLATION AND OPERATION GUIDE

INSTALLATION AND OPERATION GUIDE INSTALLATION AND OPERATION GUIDE CONGRATULATIONS on your purchase of the Airscape 1.7 Whole House Fan. This fan is designed to provide you with quiet, economical cooling for many years. Please take a few

More information

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41 Dryer User manual DV22K6800** DV22K6800-03650A-00_EN (US)_151211.indd 1 2015-12-11 7:15:41 Before installation Read through the following instructions before installing the dryer, and keep this manual

More information

VENTILATION FAN / LED LIGHT

VENTILATION FAN / LED LIGHT VENTILATION FAN / LED LIGHT MODEL ITG50LED/ITG80LED TABLE OF CONTENTS Package Contents General Safety Information Preparation 4 Assembly Instructions 5 New Construction 5 Existing Construction 6 Grille

More information

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS Fan Models: CX1401, CX1801 Read all warnings and instructions before beginning to install this fan. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

More information

Address of your installer

Address of your installer User Manual VB0038 HRV / ERV Ventilation Systems PROTECH MODELS 84-HRV100 84-HRV200 84-ERV100 84-ERV200 Address of your installer 04187-03/11/15 ABOUT THIS MANUAL/PRODUCT The purpose of this manual is

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS. User Manual HEAT RECOVERY VENTILATORS MODELS: 1000 HE HE 1.3 2000 HE HE 1.8 3000 HE HE 2.6 3055 COMPACT 5585 COMPACT VB0021 READ AND SAVE THESE INSTRUCTIONS. VVI, 550 Lemire Blvd., Drummondville, QC, Canada

More information

Installation Instructions

Installation Instructions FAVXXR6C2100-A01 Vent Damper and Control Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING ATTENTION INSTALLER: This product must be installed by a qualified

More information

HUMIDITY SENSING BATH FAN

HUMIDITY SENSING BATH FAN HUMIDITY SENSING BATH FAN MODEL VFB070B3H / SLM70H TABLE OF CONTENTS Package Contents General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions - New Construction 5 Assembly

More information

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual. IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125 EN User`s manual www.vents-us.com EN READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, READ AND UNDERSTAND

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

VENMAR AVS INSTALLATION GUIDE AVS E15 ECM ERV* AVS E15 ECM HRV* AVS E15 HRV AVS E10 HRV 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ VÄNEE

VENMAR AVS INSTALLATION GUIDE AVS E15 ECM ERV* AVS E15 ECM HRV* AVS E15 HRV AVS E10 HRV 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ VÄNEE INSTALLATION GUIDE VENMAR AVS AVS E5 ECM ERV* AVS E5 ECM HRV* AVS E5 HRV AVS E0 HRV VÄNEE 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ V00 *THESE UNITS HAVE A SPECIAL OOTING SEQUENCE, REFER TO PAGE.! RESIDENTIAL

More information

Self-Cleaning Range Hoods

Self-Cleaning Range Hoods Self-Cleaning Range Hoods Wall Mount and Island Range Hoods Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in

More information

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS VENTILATION FAN MODEL 80HLED/80L/80LED/00HLED/00LED TABLE OF CONTENTS Package Contents General Safety Information 3 Preparation Assembly Instructions 5 New Construction 5 Existing Construction 6 Connect

More information

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the cooktop. 2. The minimum distance from the cooking surface

More information

MH70230AS MH70236AS MH70248AS

MH70230AS MH70236AS MH70248AS MODEL #. MH70230AS MH70236AS MH70248AS Installation, Use and Care Guide READ AND SAVE THESE INSTRUCTIONS 2014.NOV SAFETY NOTICE... 2-3 LIST OF MATERIALS... 4 INSTALLATION Ducting Calculation Sheet...

More information

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. Page 1 of 8 RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE

More information

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 01A/02A Series Models 01A/02A Series Models RANGE HOOD LOCATION 1. The range hood must be installed just above the cooktop. 2. The minimum distance from the

More information

Heat or Energy Recovery Ventilation System

Heat or Energy Recovery Ventilation System INSTALLATION MANUAL Heat or Energy Recovery Ventilation System MODELS: FC80 HRV & FC80 ERV This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.

More information

Heat Recovery Ventilators models:

Heat Recovery Ventilators models: User s Manual Read and save these instructions. Heat Recovery Ventilators models: 1000 HE 2000 HE 3000 HE 3055 Compact HE 1.3 HE 1.8 HE 2.6 5585 Compact VB0021 VVI, 550 Lemire Blvd., Drummondville, Qc,

More information

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3 VENTILATION FAN MODEL 50F / 70F / 70HS TABLE OF CONTENTS Package Contents General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions - New Construction 5 Assembly Instructions

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR

More information

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information VENTILATION FAN MODEL Pro00/Pro300 TABLE OF CONTENTS Package Contents General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions 5 Grille Installation 6 Operation 6 Care and Maintenance

More information

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption: BX600 Innovation by Design - Since 1991 CLASSIC ColleCtion Insert Cyclone s newest insert is discreet and quiet yet bold and powerful enough to leave a distinct impression. Powered at 600 CFM and fitted

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS MODELS 170F, 174F & 178F FAN FORCED WALL HEATERS FINISH ASSEMBLIES FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING READ AND SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLING

More information

Integrated Ventilation System

Integrated Ventilation System Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

Installation Electric Dryers Instructions 01

Installation Electric Dryers Instructions 01 Installation Electric Dryers Instructions 01 Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com This is the safety alert symbol. This symbol alerts you to potential

More information

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY INSTALLATION MANUAL VB000 MODELS ERV CONSTRUCTO.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS 0798 rev. A About this Manual This manual uses the following

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3 BATH FAN / LED LIGHT MODEL GBR100LED-DECOR TABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation Assembly Instructions 5 New Construction 5 Existing Construction 6 Glass shade installation

More information

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE ITEM #0294980 0294981 TILGHMAN CEILING FAN Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. MODEL #WCK52LMW5N WCK52NWZ5N Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date ITEM #0807426 ARMITAGE CEILING FAN MODEL #CC52WW5L Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 17 ATTACH YOUR RECEIPT HERE Purchase Date 4009654 Questions, problems,

More information

Smart Choice Electric Dryer Installation Kit

Smart Choice Electric Dryer Installation Kit pn/ 5304501810 Smart Choice Electric Dryer Installation Kit BEFORE BEGINNING INSTALLATION, READ ALL MANUFACTURER S INSTALLATION INSTRUCTIONS THOROUGHLY DANGER FIRE AND ELECTROCUTION HAZARD YOU DO NOT POSSESS

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

MODEL CDB8 INSTALLATION INSTRUCTIONS

MODEL CDB8 INSTALLATION INSTRUCTIONS REV 0417 TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com SUITABLE FOR SIDE WALL OR

More information

VENTILATION FAN WITH LIGHT AND HEATER

VENTILATION FAN WITH LIGHT AND HEATER VENTILATION FAN WITH LIGHT AND HEATER MODEL RAD80L TABLE OF CONTENTS Package Contents Important Instructions 3 Preparation 4 Assembly Instructions 6 Wiring Instructions 10 Operating Instructions 10 Care

More information

Installation Instructions Preference Wall Mount Range Hood

Installation Instructions Preference Wall Mount Range Hood Installation Instructions Preference Wall Mount Range Hood For use with models PHW30 and PHW36 Part No. 101745 Rev. D Table of Contents Important Safety Instructions... 1 Important Information About Safety

More information

INSTALLATION INSTRUCTION & OWNER S GUIDE

INSTALLATION INSTRUCTION & OWNER S GUIDE INSTALLATION INSTRUCTION & OWNER S GUIDE 448 S. Main Street - P.O. Box 930040 - Verona, WI 53593-0040 Phone (608) 845-6411 - Fax (608) 845-6504 - carnes@carnes.com Air Exchanger with Heat Recovery Light

More information

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS USER GUIDE HEAT RECOVERY VENTILATS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, AND ENERGY RECOVERY VENTILAT MODEL ERV 90H-V ECM VB0124 VB0125 VB0127 VB0137 PLEASE READ AND SAVE THESE INSTRUCTIONS These

More information

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704 Installation, Operation and Maintenance Manual Item #: 403165 Rev Date: 2017-09-26 SH, VH & SE Series Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704 Your ventilation system should be installed

More information

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT VENTILATI FAN / LED LIGHT / LED NIGHT LIGHT MODEL REC80LED TABLE OF CTENTS Package Contents General Safety Information 3 Preparation Wiring Diagram 5 Assembly Instructions 6 Care and Maintenance 9 Troubleshooting

More information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE. Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

Installation Instructions Remote Blowers

Installation Instructions Remote Blowers Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or

More information

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at: WALL MOUNT RANGE HOOD This manual is made with 100 % recycled paper. Electronic version of this manual is available at: www.cosmoappliances.com Thank You Thank you for your purchase. We know that you have

More information