SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

Size: px
Start display at page:

Download "SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80"

Transcription

1 Installation & Maintenance Data IM SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80 Group: Fan coil Part Number: # Date: August 2000 Table of Contents Inspection Installation Startup Maintenance Service Replacement Parts McQuay Incorporated

2 Inspection Installation and maintenance are to be performed only by qualified personnel who are familiar with and in compliance with state, local and national codes and regulations, and experienced with this type of equipment. Caution: Sharp edges and coil surfaces are a potential injury hazards. Avoid contact with them. When the equipment is received, all items must be carefully checked against the bill of lading to be sure all crates and cartons have been received. The units are normally shipped four to a pallet. Visible or concealed damage should be reported immediately to the carrier and a claim filed to him for damage. The electrical nameplate should be checked to be sure it agrees with the power supply available. DO NOT HANDLE UNITS BY THE RISER PIPING. Riser clamps are used to hold the riser in position. They should not be expected to support the weight of the cabinet. INSTALLATION 1. Place unit over riser hole in the floor. Adjust location so riser extensions align with risers on unit below. 2. Isolator pads (not provided by McQuay) if used, must be in place before connecting riser. 3. The horizontal stubs protruding into the cabinet from the risers must be centered in the 3 (75mm) slot in the panel before risers are soldered in place. This is important to allow for riser expansion or contraction of ±1 (25mm). Riser normally extends approximately 5 (127mm) above the cabinet when the stub is centered in the slot. 4. The unit has provision for ±1 (25mm) of riser movement due to expansion or contraction. Risers must be anchored to the building structure in such a manner to prevent vertical riser movement in excess of ±1 (25mm). 5. Risers must be anchored to the building as there is no provision on the unit to support the weight of the risers. 6. Care must be taken to prevent dirt and other foreign matter from entering the risers as plugged lines or valves could result. 7. With the unit in the final location, check level to insure proper condensate drainage and operation. 8. Connect supply and return risers by soldering slip couplings. (Reducing couplings not supplied by McQuay). Join drain riser with coupling using PVC solvent cement on both surfaces (or solder if riser is copper). 9. Apply insulation (available from McQuay) to risers between floors and cement joints to avoid condensation problems. 10. To assure compliance with existing building codes, the installing contractor must restore the original fire resistance rating of the structure by sealing the access space around the risers with material having the same fire rating as the structure. This procedure is very important also in assuring that a seal is provided between floors to prevent the passage of warm, humid air which can cause condensation on riser insulation. This is most critical in unpressurized buildings with high infiltration rates. 11. Vent the coils. Vent is accessible from return air opening. 12. Hydrostatically test riser and unit connection joints to assure they are leakproof before unit is furred in. 13.The thermostat box has been installed in the front panel in the position that will allow plasterboard to be attached directly to the unit. If the installation requires that the wall be furred out away from the unit, the box can be adjusted out to 3 7 /8 (98mm) by removing the four screws "A" (see Figure 2), and pulling the box out. Replace screws "A". If a dimension other than the 3 7 /8 or 3 /8 (98mm or 10mm) is required, this can be accomplished using the angle bracket as a template and drilling.149" (4mm) diameter screw holes in the box at the desired depth. 14. When the plasterboard or other wall material does not fit flat against the face of the unit, extension sleeves must be furnished by the contractor for both the return and supply air openings. 15. Wire in accordance with local codes or the National Electric Code, whichever is applicable. Provide branch circuit overcurrent protection and disconnect means. The complete system wiring diagram is located on the front cover. Bring electrical wiring through the side of the cabinet into the wiring box located on the right-hand side of the cabinet (see Figures 3 and 5). Two 7 /8 (22mm) diameter knockouts for wire entrance are provided. 16. The unit mounted combination thermostat and fan switch has a quick disconnect plug for insertion into a receptacle in the back of the thermostat box to complete the internal wiring. The return air bulb on the thermostat must then be strung through the hole in the back of the thermostat box and down through the hole in the deck support angle and attached to the bulb clip below the fan deck (see Figure 3). Be sure the rubber grommets are in place where the capillary tube passes through the panels. 17.Rotate the fan wheel by hand to make sure the wheel is free. 18.If ducts are being added, be sure the resistance is within the limits of the external static pressures shown in the catalog for the particular unit being installed. The ducts should be designed for velocities in accordance with the methods outlined in the ASHRAE Guidebooks. It is recommended that the airborne noise be controlled with sound attenuating materials and by installing flexible connection between the unit and ductwork. Ductwork should be installed in accordance with NFPA 90A and NFPA 90B. 19.When furring in units, make sure that no screws (other than grille or plaster frame attaching screws) or nails penetrate the unit cabinet. Grille or plaster frame attaching screws should never penetrate the cabinet more than 2 (51mm). 20.The plaster frame should be attached on the opening over the top of the plasterboard. Use the plaster frame as a template to drill pilot holes into the wall or unit for the attaching screws. (See Figure 6). In order for the grille panel to fit the plaster frame properly, the plaster frame must be mounted with the corners square. When the plaster frame has been mounted to the unit, attach the two retaining clips (supplied with the plaster frame) to the plaster frame adjacent to the lower attaching screws. (See Figure 7). Page 2 / IM 255

3 Figure 1. Return Air Grille and Plaster Frame HSS/KZZ Sizes S03 Thru S08 Figure 2. Riser Location Plan View Page 3 / IM 255

4 Figure 3. HSS Installation * Riser insulation extends 1 from cabinet * * Figure 4. Unit Mounted Thermostat Box Page 4 / IM 255

5 Figure 5. Field Wiring Box for Units with Line Voltage Control Systems Figure 6. Grille Panel with Plaster Frame Figure 7. Plaster Frame Retaining Clip Installation Page 5 / IM 255

6 Start-up 1. After unit is furred in, but prior to unit start-up, make sure no foreign material remains in the unit paying particular attention to the drain pan and drain line. Blockage of the drain line will result in water overflow of the drain pan. 2. Open supply and return water service valves. 3. If unit does not have the automatic flow control option, balance water flow rate with hand valve on return line. 4. Replace front access cover (see Figure 3). 5. Put filter into position. 6. Install return air grille. Maintenance 1. Filters must be clean to obtain maximum unit performance. They should be inspected every three or four months under normal operating conditions and be replaced when necessary. Units should never be run without a filter. 2. In areas where airborne bacteria produce growth in the drain pan, it may be necessary to treat chemically to minimize the problem. Contact your local sales representative or one of the many companies dealing with water conditioning. 3. The condensate drain pan can pick up lint and dirt, especially with dirty filters. Inspect twice a year to avoid the possibility of overflow. Service 1. If fan or motor service is required on the S03 or the S04, the fan motor can be removed through the return air opening as follows: a. Shut off electrical power to unit. b. Remove return air grille panel. c. Remove front access cover. d. Disconnect the fan motor leads at the wiring box. e. Remove the bottom half of the fan housing by taking out the two screws on the housing. f. Remove the clips that hold the motor to the motor base. g. Remove the motor. h. Fan wheel is pressed on motor shaft, pull to remove. i. Reverse process to reassemble. 2. If fan motor service is required on the S06 or S08, the fan motor can be removed through the return air opening as follows: a. Shut off electrical power to unit. b. Remove return air grille panel. c. Remove front access cover (see Figure 3). d. Disconnect the fan motor leads at the wiring box. e. Remove the screws that hold the inlet ring to the fan housing. f. Remove the fan wheel, motor, and inlet ring assembly from the fan housing. g. Loosen fan wheel setscrew. Replacement Parts When writing for service or replacement parts, direct your letters to McQuayService, and refer to the model number and the serial number of the heater as stamped on the serial plate attached to the heater kit. If replacement parts are 7. All windows and doors should be in and closed before starting up the unit. 8. Switch unit to "on" and check for proper operation of fans, fan speed switch, and thermostat. 9. When there is a high amount of moisture in the air, the initial pulidown should be very gradual (high fan speed for maximum air flow with reduced GPM and elevated chilled water temperature for reduced capacity). Outside air supply and toilet exhaust systems should not be operated until the gradual pulldown has been completed. If these steps are taken, the possibility of the unit sweating will be reduced. 4. The fan motor has been oiled at the factory. It is not necessary to oil the first six months under continuous operation. Oil every six months with one teaspoon or five cc per bearing of SAE No. 20 nondetergent oil. Do not overlubricate. 5. The coil must be clean to obtain maximum performance. Check once a year under normal operating conditions, and if dirty, brush or vacuum clean. Care must be taken not to damage the aluminum fins while cleaning. Caution: Fin edges are sharp. h. Remove the three screws holding the motor to the inlet ring. i. Service can now be performed. j. Reverse process to reassemble. 3. The electric heater elements, if furnished, are designed with high limit control set to trip out if the cabinet temperature becomes excessive and automatically reset when the cabinet temperature returns to normal. If the high limit is opening the circuit, the unit is not performing properly and should be checked to find the cause. Some probable causes would be not enough air over the heater due to dirty filter, fan motor not operating, dirty coil, fan wheel loose on the motor shaft, or loose electrical connections. 4. If the electric heater should require service, it can be done in the following manner: a. Shut off electrical power to the unit. Caution: There may be more than one power source on the unit. b. Remove the return air grille and front access cover. c. Remove the electric heater junction box cover. d. The high-limit control can be replaced without removing the element from the unit. It is done by removing the nut on the appropriate terminal post and lifting the defective part out. e. The entire element can be removed by disconnecting the wires from the terminal posts and removing the screws in the back of the junction box that hold the heater to the support bracket. Slide the heater out and replace. f. The electric heater contactor is located in the field wiring box (see Figures 3 and 5). required, give the date of the heater kit installation and the date of the failure; also, give description of replacement parts and explanation of malfunction. Page 6 / IM 255

7 Notes Page 7 / IM 255

8 AAF-McQuay Incorporated 4900 Technology Park Boulevard, Auburn, New York USA (315) Printed on recycled paper containing at least 10% post-consumer recycled material.

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12 Installation & Maintenance Data IM 168-5 SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12 Group: Fan coil Part Number: # 107132900 Date: June 1999 Table of Contents Inspection............................................................................

More information

Installation & Maintenance Data IM Contents

Installation & Maintenance Data IM Contents Installation & Maintenance Data IM 254-4 Group: Fan Coil Part Number: 107133000 Date: June 1999 SeasonMaker HiLine Fan-coil Units Type KZZ Contents Inspection..................................... 2 Riser

More information

Ceiling Concealed Fan-Coil Unit

Ceiling Concealed Fan-Coil Unit Installation & Maintenance Manual IM 745 Group: Fan-coil Part Number: 106333001 Date: November 2009 Ceiling Concealed Fan-Coil Unit Models: THC02, THC03, THC04, THC06, THC08, THC10, THC12 Table of Contents

More information

Installation Manual IM

Installation Manual IM Installation Manual IM 255-10 HiLine Fan Coil Unit Models FHSS 103 through 108 Group: Fan Coils Part Number: 910227748 Date: January 2018 2018 Daikin Applied Table of Contents Table of Contents General

More information

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with

More information

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT Carrier International Sdn. Bhd. Malaysia INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT 40LM 120-200 50Hz CONTENTS: Physical Data & Dimension 1-3 Safety Considerations 4 Rigging

More information

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog HiLine Vertical Stacking Fan Coils Type FHSS and FHSK Catalog 770-17 Table of Contents Introduction.... 3 Daikin Applied HiLine Fan-Coil Units...3 Nomenclature...3 Introduction.... 4 Low CFM design (300

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information

Installation, Operating & Maintenance Instructions. Air Handler Models: AH & AV

Installation, Operating & Maintenance Instructions. Air Handler Models: AH & AV Installation, Operating & Maintenance Instructions Air Handler Models: AH & AV Table of Contents Table of Contents... 2 Product Safety... 2 Important Information About Safety Instructions... 2 Receiving...

More information

Installation and Maintenance Manual IM 254-7

Installation and Maintenance Manual IM 254-7 Installation and Maintenance Manual IM 254-7 HiLine Vertical Stacking Fan Coil Unit Group: Fan Coils Part Number: 910227750 Date: January 2018 Models FHSK 103 through 108 Table of Contents Table of Contents

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

Vertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE

Vertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE MANUAL INSTALLATION, OPERATION, & MAINTENANCE Vertical Concealed Fan Coil FCVC Series v100 Issue Date: 12/21/15 2015 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant

More information

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

Installation, Operating & Maintenance Instructions. Horizontal Models: LH & HL

Installation, Operating & Maintenance Instructions. Horizontal Models: LH & HL Installation, Operating & Maintenance Instructions Horizontal Models: LH & HL Table of Contents Table of Contents... 2 Product Safety... 2 Important Information About Safety Instructions... 2 Receiving...

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

Installation and Maintenance Manual IM 168-8

Installation and Maintenance Manual IM 168-8 Installation and Maintenance Manual IM 168-8 HiLine Vertical Stacking Fan Coil Unit Group: Applied Air Systems Part Number: 910227749 Date: January 2018 Models FHSS 110 and FHSS 112 Table of Contents Nomenclature....

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING

More information

Installation, Operating & Maintenance Instructions. Vertical Stack Models: ER & DR

Installation, Operating & Maintenance Instructions. Vertical Stack Models: ER & DR Installation, Operating & Maintenance Instructions Vertical Stack Models: ER & DR Table of Contents Table of Contents... 2 Product Safety... 2 Important Information About Safety Instructions... 2 Receiving...

More information

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS 6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 Web: www.temspec.com TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS INSTALLATION AND MAINTENANCE

More information

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS 6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 www.temspec.com Vertical Stack Fan Coil Units Models: TVA, TVE, TVS INSTALLATION, OPERATION AND MAINTENANCE

More information

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

HiLine Vertical Stacking Fan-coil Units

HiLine Vertical Stacking Fan-coil Units Catalog C: 770-12 HiLine Vertical Stacking Fan-coil Units Type HSS & KZZ ARI 440 CUL Listed McQuay SeasonMaker HiLine fan-coil units The McQuay HiLine SeasonMaker fan-coil air conditioning units are designed

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IFB HEATING COILS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IFB HEATING COILS IOMIFB-6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL IFB HEATING COILS ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THESE

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5 Introduction The Scotsman Compact Refrigerator is a unique product, capable of being built into a cabinet because of its front vented, forced-air cooling system. It s also designed to be a companion to

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T50 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-203 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

HiLine Vertical Stacking Fan Coil Units

HiLine Vertical Stacking Fan Coil Units Catalog C: 770-13 HiLine Vertical Stacking Fan Coil Units Type HSS & KZZ CUL Listed McQuay HiLine fan coil units McQuay HiLine fan coil air conditioning units are designed for use in multiple floor apartments,

More information

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG 49FH, 49FP, 49BF, 49WS, & 49BG HUMIDIFIERS READ AND SAVE THESE INSTRUCTIONS Model 49FH Fan-Powered A95248 Model 49FP Fan-Powered A95249 Model 49BF Bypass A95250 Model 49WS Water-Saver Bypass A95251 Model

More information

Installation Instructions

Installation Instructions Installation Instructions Fan Coil Units FG3A NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Improper

More information

40 RM/RMS Packaged Air-Handling Units

40 RM/RMS Packaged Air-Handling Units ConcepcionCarrier Air conditioning Company Philippines 40 RM/RMS 008034 Packaged AirHandling Units INSTALLATION MANUAL, STARTUP & SERVICE INSTRUCTIONS Contents Page Page Safety Considerations 1 40RM Physical

More information

R Series B & T2 Model

R Series B & T2 Model FRONT R Series B & T2 Model Fan Forced Wall Heaters 4-1/4 (108mm) NOTE: Knockouts in top same dimensions 3-1/4 3-1/4 (108mm) (108mm) as bottom 16-7/8 (429mm) 13-7/8 (352mm) BOTTOM 13-7/8 (352mm) 7-3/4

More information

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N GENESIS Air Conditioners All Models INSTRUCTION MANUAL Rev. K P/N 89104462 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

INSTALLATION MANUAL TVS FAN COIL UNITS VERTICAL HIGH-RISE. Redefine your comfort zone.

INSTALLATION MANUAL TVS FAN COIL UNITS VERTICAL HIGH-RISE. Redefine your comfort zone. INSTALLATION MANUAL TVS FAN COIL UNITS VERTICAL HIGH-RISE TVS FANCOIL UNITS VERTICAL HIGH RISE Table of Contents Table Of Contents...2 Safety Symbols...3 Safety Considerations...3 Series Features...5 Section

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

Installation Instructions

Installation Instructions CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL SWP (Models SWP08 through SWP20) OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended

More information

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58 Commercial School Milk Cooler User s Manual Commercial School Milk Coolers: MC34, MC49, MC58 12/2015 Please read the manual thoroughly prior to equipment set-up, operation and maintenance. - 1 - Exploded

More information

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

Construction Standards Page

Construction Standards Page Construction Standards Page 236313-1 SECTION 236313 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature Your Warranty The manufacturer, Lanco, warrants this fan coil to the original purchaser under the following conditions: LIMITED ONE-YEAR WARRANTY 1. Any part thereof which proves to be defective in material

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

SECTION FAN COIL UNITS

SECTION FAN COIL UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions CHEF BASE CABINETS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS 7,000-14,000 Btuh CONTENTS Page GENERAL....................................... 2 UNIT INSPECTION.............................2,3

More information

IMPORTANT! READ BEFORE PROCEEDING! CI3H - CI12H, CI81S Ceiling & Inline Fans

IMPORTANT! READ BEFORE PROCEEDING! CI3H - CI12H, CI81S Ceiling & Inline Fans CI3H - CI12H, CI81S Ceiling & Inline Fans OPERATION & MAINTENANCE Revised: 08/24/15 IMPORTANT! READ BEFORE PROCEEDING! The information contained herein is, to the best of our knowledge, accurate and applicable

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

C. Samples for Initial Selection: For units with factory-applied color finishes.

C. Samples for Initial Selection: For units with factory-applied color finishes. SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions B2451 & B2452 Series Wall Heaters SPECIFICATIONS MODEL VOLTS HZ AMPS WATTS BTUH B2451 120 60 12.5 1500 5120 B2452 240 60 8.3 2000 6826 208 60 7.2 1500 5120 DIMENSIONS OVERALL Height - 14 1/4 Width - 11

More information

SERIES B VERTICAL FLOOR FAN COIL UNIT

SERIES B VERTICAL FLOOR FAN COIL UNIT BY JOHNSON CONTROLS Installation, Operation & Maintenance SERIES B VERTICAL FLOOR FAN COIL UNIT New Release Form ET115.24-NOM9 (908) Model VFC/VFE/VFS TABLE OF CONTENTS TABLE OF CONTENTS...2 SAFETY SYMBOLS...3

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Air Cooled Condensers 8-2016 Rev 0 Table of Contents General Safety Information 2 Inspection 2 Installation 2 6 Rigging and Assembly 2 Unit Location

More information

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Fan Column v200 Issue Date: 01/18/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General Safety Information...1 Safety Notices...1 Unit Description...2

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Installation Instructions

Installation Instructions Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper

More information

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N V-SERIES Air Conditioner VA08 Model INSTRUCTION MANUAL Rev. F P/N 90164959 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Installation, Operating & Maintenance Instructions. High Performance Horizontal Models: HH & CH

Installation, Operating & Maintenance Instructions. High Performance Horizontal Models: HH & CH Installation, Operating & Maintenance Instructions High Performance Horizontal Models: HH & CH Table of Contents Table of Contents... 2 Product Safety... 2 Important Information About Safety Instructions...

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

MODEL HUM HUMIDIFIERS

MODEL HUM HUMIDIFIERS HOMEOWNER S MANUAL MODEL HUM HUMIDIFIERS Model HUMBBLFP1025-A-- Fan-Powered Humidifier Model HUMBBSFP1016-A-- Fan-Powered Humidifier Model HUMBBLBP2018-A-- Bypass Humidifier Model HUMBBSBP2017-A-- Bypass

More information

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE DR-180 Through the Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

Type K Incremental Packaged Terminal Air Conditioner

Type K Incremental Packaged Terminal Air Conditioner Installation & Maintenance Data IM 1068 Group: PTAC Part No.: 669729001 Date: March 2010 Type K Incremental Packaged Terminal Air Conditioner Incremental Room Conditioner with R-410A Refrigerant 2010 McQuay

More information

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control Australian Version Electronic Wall Control 1 Introduction The BR342 reverse cycle rooftop air-conditioner is designed for installation onto Recreational Vehicles (RV s) at the time of manufacture or as

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL T Edition 0 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 88 STRATFORD, CT 0665

More information

Installation and Operation Manual For Hunter Ceiling Fans

Installation and Operation Manual For Hunter Ceiling Fans Installation and Operation Manual For Hunter Ceiling Fans 1 2 CONGRATULATIONS! Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years.

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Induction Unit. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

Induction Unit. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air Induction Unit Installation, Operation and Maintenance Heating Cooling Fresh Air Clean Air i Models and arrangements 1 Performance data 3 Dimensions and data 12 General information 21 Receiving 21 Safety

More information

Installation Instructions

Installation Instructions CNPHP Cased N s Horizontal Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION...

More information

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT USER S MANUAL AND INSTALLATION INSTRUCTIONS P3BD Series 13 SEER Single Package Air Conditioner IMPORTANT Read this owner information to become familiar with the capabilities and use of your appliance.

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A CS 2 Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual Form No. 6120A TABLE OF CONTENTS Page Inspection... 2 Shipment of Units... 2 Handling... 2 Installation...

More information

INSTRUCTION MANUAL with Replacement Parts

INSTRUCTION MANUAL with Replacement Parts INSTRUCTION MANUAL with Replacement Parts MODEL FD500 FOOD WASTE DISPOSERS (INCLUDES MOTOR PARTS) ML-18978 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 11394 Rev. G (10-98)

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Installation and Maintenance Manual IM

Installation and Maintenance Manual IM Installation and Maintenance Manual IM 1152-2 ThinLine Horizontal Fan Coils and Cabinet Unit Heaters Group: Fan Coil Part Number: 910175957 Date: October 2015 Type FC and FH Exposed Horizontal Cabinet

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

Modular Hi-Rise Series Fan Coils INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Modular Hi-Rise Series Fan Coils INSTALLATION, OPERATION, & MAINTENANCE MANUAL Modular Hi-Rise Models: MPY, MXY, MAY/MBY Ditto, MMY/MSY, MUY, and MGY BUILD YOUR REPUTATION ON OURS International Environmental Corporation (IEC) works continually to improve its products. As a result,

More information

USER S MANUAL EUROPEAN SCRUB-PRO GOLF BALL CLEANSER

USER S MANUAL EUROPEAN SCRUB-PRO GOLF BALL CLEANSER USER S MANUAL EUROPEAN SCRUB-PRO GOLF BALL CLEANSER Magnum Scrub-Pro Golf Ball Cleanser is made with a durable polyethylene body and a tubular steel powder coated frame. Features include scattered trim

More information

Horizontal & Horizontal Quiet Blower Coils

Horizontal & Horizontal Quiet Blower Coils MANUAL INSTALLATION Horizontal & Horizontal Quiet Blower Coils BCH / BCHQ Series v200 Issue Date: 05/19/15 2015 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 INSTALLATION-OPERATION-MAINTENANCE CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 TEFC 3 phase motor Outlet duct Fan wheel housing Inlet duct connection After filter transition Optional after filter unit

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information