1 Product Guide Wallmount Air Conditioners & Heat Pumps

2 Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified High/ low pressure switches R4A Refrigerant Barometric damper gauge galvanized steel Expansion valves are standard on H series heat pumps, TV & TH series, SV & SH series Flow raters and pistons are standard on V series Built-in Circuit Breaker (Disconnect on volt models) air filter Mesa Tan color Scroll compressors Phase Monitors on 3 phase units Made in USA

3 Optional Features page 3 See Descriptions on Pages,, 2 Fresh Air Options Economizer Powered Room Ventilator (PRV) Energy Recovery Ventilator (ERV) available on S & T models only Low Ambient Package Sound Attenuation Module (SAM) Lead lag Controller Coated Coils 2 Pleated Filters Return & Supply Grilles White, Gray Cabinet Colors Digital Thermostat 3 Ton Back plate for 4 & 5 ton models Electric Heat Strips

4 EER V Series Air Conditioners H Series Heat Pumps Efficiency ratings from EER & 3.0 COP Available sizes:.5 to 5.0 ton Air Conditioners, 2.0 to 5.0 ton Heat Pumps 5 year limited warranty on parts and compressor Eubank Wallmount Model Key V 4 3 B A F D S - N B * N = Non Coated Coils 4 = Coated Coil Series Nominal Capacity Fresh Air D = Disposable Filter V = A/C 4=R4A =.5 Ton Electric Heat F = Barometric Damper P = 2 Pleated Filter H = Heat pump 24 = 2.0 Ton 05 = 05KW E = Economizer Cabinet Color = 2.5 Ton 0 = 0KW B = Solid Door B = Mesa Tan 3 = 3.0 Ton = KW P = PRV (Powered Room Ventilator) W = White 4 = 4.0 Ton = KW Electric Supply G = Gray 0 = 5.0 Ton 5 = 5KW = 20-2//0 = KW 3 = 20-2/3/0 C = Low ambient pkg Compressor type = Copeland Scroll 20 = 20KW 4 = /3/0 V Series Air Conditioners EER Model Cooling Capacity Volt/Phase/Hertz Weight Shipping/Net V4B**A, //0 22/205 V424B**A 23, //0 22/205 V4B**A 2,0 20-2//0 34/32 V4B**A3 2,0 20-2/3/0 34/32 V43B**A 35, //0 352/324 V43B**A3 35, /3/0 352/324 V43B**A4 35,000 /3/0 352/324 V44B**A 44, //0 44/450 V44B**A3 44, /3/0 44/450 V44B**A4 44,000 /3/0 44/450 VB**A 55, //0 525/55 VB**A3 55, /3/0 525/55 VB**A4 55,000 /3/0 525/55 See Complete Specifications on Pages to

5 V Series Electric Heaters & AC Unit Combinations for EER Voltage Size Part Number *Amps * BTU Output //0 5 kw EGA05B-AC 20. 7,000 kw EGAB-AC 4. 34,000 5 kw EGH5B-AC 2.5 5, kw EGH20B-AC 3,000 X X 2/3/0 kw EGH0B3-AC ,000 X X kw EGH0B3-AC 2.7 3,000 X X 5 kw EGH5B3-AC 3 5,000 kw EGHB3-AC 43.3,000 X X /3/0 kw EGH0D4-AC ,000 kw EGH0D4-AC. 3,000 5 kw EGH5D4-AC.0 5,000 X X H Series Heat Pumps EER Model Cooling Capacity Heating Capacity Volt/Phase/Hertz Weight Shipping/Net H424B**A 23,00 23, //0 22/205 H4B**A 2,0 2, //0 34/32 H4B**A3 2,0 2, /3/0 34/32 H43B**A 35,000 34, //0 352/324 H43B**A3 35,000 34, /3/0 352/324 H43B**A4 35,000 34,000 /3/0 352/324 H44B**A 44,000 45, //0 44/450 H44B**A3 44,000 45, /3/0 44/450 H44B**A4 44,000 45,000 /3/0 44/450 HB**A 55,000 54, //0 525/55 HB**A3 55,000 54, /3/0 525/55 HB**A4 55,000 54,000 /3/0 525/55 H Series Electric Heaters & Heat Pump Unit Combinations Voltage Size Part Number *Amps *BTU Output //0 5 kw EGH05B-HP 20. 7,000 X X kw EGHB-HP 4. 34,000 X X 2/3/0 kw EGH0B3-HP ,000 X X kw EGH0B3-HP 2.7 3,000 X X /3/0 kw EGH0D4-HP ,000 X kw EGH0D4-HP. 3,000 X * BTU output and current based on 2 volts for 20-2 volts models and volts for volts models. * BTU multiplier for 2 volts operation multiply the listed output by 0.2; for 20 volts operation multiply by 0.75; for volts operation multiply by 0.2. * Current multiplier for 2 volts operation multiply by 0.; for 20 volts operation multiply by 0.7; for volts operation multiply by 0.. Easiest to Service! Condenser Coil is in the Back! See Complete Specifications on Pages to

6 High Efficiency T Series TV Series Air Conditioners TH Series Heat Pumps High Efficiency ratings up to 4 IPLV, + EER & 3.0 COP Available sizes: 3.0 to 5.0 ton Air Conditioners & Heat Pumps 5 year limited warranty on parts and compressor NOM ENCL AT U R E TV 3 S - FB - 00 MODEL SERIES TV = AIR CONDITIONER + EER SERIES TH = HEAT PUMP + EER SERIES SV = AIR CONDITIONER LOW SOUND SERIES SH = HEAT PUMP LOW SOUND SERIES NOMINAL COOLING CAPACITY 3 = 3,000 BTU/H NOMINAL ELECTRICAL SERVICE S = 20-2//0 T = 20-2/3/0 D = /3/0 ELECTRIC STRIP HEATER = kw Options Codes C = Low ambient kit B= Mesa Tan cabinet color (Std) 2= Coated cond coil G= Grey cabinet color P = MERV filter W= White cabinet color S = 2 step compressor FRESH AIR F = BAROMETRIC DAMPER (Std) E = ECONOMIZER B = SOLID DOOR P = PRV - Powered Room Ventilator V = ERV - Energy Recovery Ventilator TV Series Air Conditioners EER Model IPLV w/ 2 Step Compressor Cooling Capacity Volt/Phase/Hertz Weight Shipping/Net TV3S** 4 33, //0 370/350 TV3T** 4 33, /3/0 370/350 TV3D** 4 33,000 /3/0 370/350 TV4S** 3. 44, //0 55/500 TV4T** 3. 44, /3/0 55/500 TV4D** 3. 44,000 /3/0 55/500 TV0S** 2 55, //0 520/500 TV0T** 2 55, /3/0 520/500 TV0D** 2 55,000 /3/0 520/500 See Complete Specifications on Pages 20 to 23

7 TV Series Electric Heaters & AC Unit Combinations EER Voltage Size Part Number *Amps * BTU Output //0 5 kw ETA ,000 kw ETA ,000 5 kw ETA , kw ETA-20 3,000 X X 2/3/0 kw ETA ,000 kw ETA ,000 5 kw ETA ,000 kw ETA3-43.3,000 X X /3/0 kw ETA ,000 kw ETA4-0. 3,000 5 kw ETA ,000 TH Series Heat Pumps EER Model Cooling Capacity Heating Capacity Volt/Phase/Hertz Weight Shipping/Net TH3S** 33,000 24,0 20-2//0 30/ TH3T** 33,000 24,0 20-2/3/0 30/ TH3D** 33,000 24,0 /3/0 30/ TH4S** 44,000 44, //0 525/5 TH4T** 44,000 44, /3/0 525/5 TH4D** 44,000 44,000 /3/0 525/5 TH0S** 55,000 52, //0 5/5 TH0T** 55,000 52, /3/0 5/5 TH0D** 55,000 52,000 /3/0 5/5 TH Series Electric Heaters & Heat Pump Unit Combinations EER Voltage Size Part Number *Amps *BTU Output //0 5 kw ETA-05-HP 20. 7,000 kw ETA--HP 4. 34,000 2/3/0 kw ETA ,000 kw ETA ,000 /3/0 kw ETA ,000 kw ETA4-0. 3,000 * BTU output and current based on 2 volts for 20-2 volts models and volts for volts models. * BTU multiplier for 2 volts operation multiply the listed output by 0.2; for 20 volts operation multiply by 0.75; for volts operation multiply by 0.2. * Current multiplier for 2 volts operation multiply by 0.; for 20 volts operation multiply by 0.7; for volts operation multiply by 0.. ENERGY RECOVERY VENTILATOR Pre-Conditions Fresh Air Using Exhaust Air FOR + EER EUBANK UNITS See Complete Specifications on Pages 20 to 23

8 High Efficiency Low Sound S Series SV Series Air Conditioners SH Series Heat Pumps High Efficiency ratings up to 4 IPLV, + EER & 3.0 COP Available sizes: 3.0, 4.0 & 5.0 ton Air Conditioners & Heat Pumps 5 year limited warranty on parts and compressor NOM ENCL AT U R E SV 3 S - FB - 00 MODEL SERIES TV = AIR CONDITIONER + EER SERIES TH = HEAT PUMP + EER SERIES SV = AIR CONDITIONER LOW SOUND SERIES SH = HEAT PUMP LOW SOUND SERIES NOMINAL COOLING CAPACITY 3 = 3,000 BTU/H NOMINAL ELECTRICAL SERVICE S = 20-2//0 T = 20-2/3/0 D = /3/0 ELECTRIC STRIP HEATER = kw Options Codes C = Low ambient kit 2= Coated cond coil B= Mesa Tan cabinet color (Std) P = MERV filter G= Grey cabinet color W= White cabinet color FRESH AIR F = BAROMETRIC DAMPER (Std) E = ECONOMIZER B = SOLID DOOR P = PRV - Powered Room Ventilator V = ERV Energy Recovery Ventilator SV Series Air Conditioners EER Model IPLV Cooling Capacity Volt/Phase/Hertz Weight Shipping/Net SV3S** 4 33, //0 535/55 SV3T** 4 33, /3/0 535/55 SV3D** 4 33,000 /3/0 535/55 SV4S** 3. 44, //0 7/5 SV4T** 3. 44, /3/0 7/5 SV4D** 3. 44,000 /3/0 7/5 SV0S** 2 55, //0 75/700 SV0T** 2 55, /3/0 75/700 SV0D** 2 55,000 /3/0 75/700 See Complete Specifications on Pages 24 to 27

9 SV Series Electric Heaters & AC Unit Combinations EER Voltage Size Part Number *Amps * BTU Output //0 5 kw ETA ,000 kw ETA ,000 5 kw ETA , kw ETA-20 3,000 X X 2/3/0 kw ETA ,000 kw ETA ,000 5 kw ETA ,000 kw ETA3-43.3,000 X X /3/0 kw ETA ,000 kw ETA4-0. 3,000 5 kw ETA ,000 SH Series Heat Pumps EER Model Cooling Capacity Heating Capacity Volt/Phase/Hertz Weight Shipping/Net SH3S** 33,000 2, //0 545/525 SH3T** 33,000 2, /3/0 545/525 SH3D** 33,000 2,500 /3/0 545/525 SH4S** 43,500, //0 720/705 SH4T** 43,500, /3/0 720/705 SH4D** 43,500,000 /3/0 720/705 SH0S** 55,000 52, //0 725/7 SH0T** 55,000 52, /3/0 725/7 SH0D** 55,000 52,000 /3/0 725/7 SH Series Electric Heaters & Heat Pump Unit Combinations EER Voltage Size Part Number *Amps *BTU Output //0 5 kw ETA-05-HP 20. 7,000 kw ETA--HP 4. 34,000 2/3/0 kw ETA ,000 kw ETA ,000 /3/0 kw ETA ,000 kw ETA4-0. 3,000 * BTU output and current based on 2 volts for 20-2 volts models and volts for volts models. * BTU multiplier for 2 volts operation multiply the listed output by 0.2; for 20 volts operation multiply by 0.75; for volts operation multiply by 0.2. * Current multiplier for 2 volts operation multiply by 0.; for 20 volts operation multiply by 0.7; for volts operation multiply by 0.. World s Quietest Compact Wallmount by Eubank Reduces Inside Sound by % or More* Uses Same Wall Openings Does Not take Indoor Space SH SERIES * percentage reduction varies with site conditions See Complete Specifications on Pages 24 to 27

10 Optional Features page Low Ambient Kit Controls the head pressure in low outdoor temperature conditions. Head pressure is is maintained to keep the low pressure high enough to avoid a freeze up on the evaporator coil. Kit includes pressure Switch, crankcase heater and a control board with alarm contacts Coated Coils Coils can be coated for protection against corrosive attack. For use in areas where chemicals are present or near salt water. Electric Heaters Heat strips are available factory installed or as a kit to install in the field Models for AC & Heat Pump from 5KW. See heater and unit combinations tables for specific model 2 Pleated Filters Increase air filtration with a 2 pleated MERV filter. Fits into the same space as the standard disposable filter. Supply Grilles & Return Filter Grilles Exact fit inside grilles for Eubank AC & heat pump units. Available in white color only.

11 Optional Features page Fresh Air Options Powered Room Ventilator (PRV) The PRV is designed to operate any time the indoor fan motor is energized. Circulates up to 0% fresh air into the indoor while exhausting air out. Economizer Automatically regulated economizer is designed to cool the indoor space with outdoor air without running compressor when outdoor conditions permit. Control is based on outside temperature & humidity. Capable of delivering 0% fresh air. Energy Recovery Ventilator (ERV) for EER models only Pre-conditions incoming fresh air with exhaust air to transfer heat and moisture to save energy. Fits inside Eubank EER AC & Heat Pump models. Lead-Lag Controllers Available for AC units only, lead-lag controllers are designed to balance the operating run time between two AC units. To avoid down time on critical installations, two units each capable of providing 0% of the cooling are installed. The lead-lag controller operates one unit at a time sequencing their on & off times to prolong unit life. Non-Programmable Digital Thermostat Simple to use digital non-programmable thermostat from Eubank can be configured for either auto changeover or manual operation. Lockout features protect the settings from Being changed without a password. Thermostat is 24 VAC with an LCD display and a blue/green backlight. Dimensions are W x 4 H x.5 D in white. Order for heat/cool or for heat pump.

12 Optional Features page 2 Sound Attenuation Module - (SAM) Fits between wallmount units and the wall. Exclusive internal engineering design manages air direction attenuating and reducing the sound level from the unit to the inside space. Actual sound reduction ratios vary with application. Optional for all Eubank V, H and T series wallmounts and fits many competitors wallmounts that are EER or less. SAM-A-0 for 3 ton or less, SAM-B-0 for 3.5 to 5 ton 3 Ton Back Plate for 4 & 5 Ton Models Allows replacement of a 3 ton unit with a 4 or 5 ton unit without modifying existing wall openings. Back plate aligns the existing return and supply vents in the installation with a 4 or 5 ton unit. Optional Unit Colors External unit color is available in optional white or gray color. Standard color is Mesa Tan.

13 Questions for Replacing a Wallmount without a Model Number _page 3. Air conditioner or heat pump? 2. Which model? V&H series EER T series + EER S series + EER with sound attenuation module & 2 step compressor 3. What is the capacity? V series -.5, 2, 2.5, 3, 4 5 H series - 2, 2.5, 3, 4, 5 T series - 3, 4, 5 S series - 3, 4, 5 4. What voltage and phase are needed? 2//0 2/3/0 /3/0 5. Do they need electric heat strip and if so, what size?. What feature do they want for fresh air? V&H series - Barometric (std), Economizer, Power Room Ventilator, T series - Barometric (std), Economizer, Power Room Ventilator, ERV S series - Barometric (std), Economizer, Power Room Ventilator, ERV 7. Standard inch filter or 2 inch pleated MERV?. Coated coils for corrosive conditions?. Standard Mesa Tan color, Gray or White cabinet?. Do they need protection for low ambient temperature conditions?. Compare answers to Eubank Model Number Key on following page to determine Eubank model number

14 Wallmount Model Keys page 4 Bard Wallmount Model Key WA 3 A - A X X A Series Revision Electric Supply Fresh Air Cabinet Colors Control Modules WA = Right side A = 2/20-0- X = Barometric X = Beige Control panel A = A/C B = 2/ Damper = white Coil & compressor H = Heat pump C = /0/3 B = Blank off 2 = Mesa tan X = standard WL = Left side plate 4 = gray = phenolic coated evap Control panel M = Motorized 5 = desert brown 2 = phenolic coated cond & compressor Electric Heat damper = dark bronze 3 = phenolic coated evap & S = blow through 04 = 4KW V = spring return A = aluminum condenser W = draw through Capacity 05 = 5 KW E = economizer S = stainless 7 =.5 Ton 42 = 3.5 Ton = KW D = economizer =.5 Ton 43 = 3.5 Ton 0 = KW R = ERV Outlet 24 = 2 Ton 4 = 4 Ton 0 = KW X = front 2 = 2 Ton 4 = 4 Ton = KW N = no filter T = top = 2.5 Ton 0 = 5 Ton 5 = 5KW X = disposable 3 = 2.5 ton = 5 Ton 20 = 20KW W = washable 3 = 3 Ton P = 2 pleated 3 = 3 Ton H = 2 pleated Marvair Wallmount Model Key AVP S A 3 AC A 0 X N X Compressor type A = R4A Capacity AC = A/C Electric heat Brand name Special options 24 = 2 Ton HP = heat pump 000 = none Air Source = 2.5 Ton 0 = 4KW Fresh Air Vertical Package 3 = 3 Ton Voltage 050 = 5KW N = manual damper (wallmount) 42 = 3.5 Ton A = 20/2/ 00 = KW Y = adjustable damper 4 = 4 Ton C = 20/2/3 00 = KW Z = adjustable damper 4 = 4 Ton D = /3 00 = KW B = motorized damper 0 = 5 Ton 0 = KW C = Economizer 20 = 2KW H = ERV 50 = 5KW Eubank Wallmount Model Key V 4 3 B A F D S - N B A N = non coated coil 4 = coated coil Series Capacity Fresh Air D = Disposable Filter V = A/C 4=R4A =.5 Ton Electric Heat F = Barometric Damper P = 2 Pleated Filter H = Heat pump 24 = 2.0 Ton 05 = 05KW E = Economizer Cabinet Color = 2.5 Ton 0 = 0KW B = Solid Door B = Mesa Tan 3 = 3.0 Ton = KW P = PRV (Powered Room Ventilator) W = White 4 = 4.0 Ton = KW Electric Supply 0 = 5.0 Ton 5 = 5KW = 20-2//0 A = Hi & Low pressure switch = KW 2 = 20-2/3/0 C = Low ambient pkg Compressor type = Copeland Scroll 20 = 20KW 4 = /3/0 2 = All of the above

15 Unit Dimensions for V, H and T series Eubank (Current)) Tonnage A B C D E F G H I J K L / / /4/ Tonnage A B C D E F G H I J K L Bard WA Series / N/A. N/A N/A / N/A 27. N/A N/A /4/ N/A 2. N/A N/A 4.75 Marvair AVP Series Tonnage A B C D E F G H I J K L / / /4/

16 Dimensions, S series page

17 Specifications Section Schools Offices Leasing Companies Modular Bldgs. Trailers Storage Cell Towers Equipment Hubs Oilfield

18 V Series AC Specifications page AC Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) V4**A, //0.0 / "/2000 / /0. V424**A 23, //0 2. / "/2000 / /0. V4**A 2,0 20-2//0 / "/2000 / /0.5 V4**A3 2,0 20-2/3/0 / "/2000 / /0.5 V43**A 35, //0 7. / "/2000 / /0.5 V43**A3 35, /3/0 3.2 / "/2000 / /0.5 V43**A4 35,000 /3/0 / "/2000 / /0.5 V44**A 44, //0 2.4 / "/00 / /0.20 V44**A3 44, /3/0 4.5 / "/00 / /0.20 V44**A4 44,000 /3/0 7. / "/00 / /0.20 V**A 55, //0. / "/00 / /0.20 V**A3 55, /3/ / "/00 / /0.20 V**A4 55,000 /3/0. / "/00 / /0.20 (J) Rated in accordance with ANSI/ARI Standard (K) Includes factory-installed filters and wet coils Standard Ventilation Package AC Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper V4 70/25% V /25% V4 0/25% V43 0/25% V44 450/25% V 525/25% 25"X"X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models V Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit AC Model 5 0 Total Sensible Total Sensible V4,000 2,000,000 3,000 V424 23,00 7,000 25,200 7,000 V4 2,0 2,0 3,0 22,000 V43 35,000 2,000 37,0 25,000 V44 44,000 34,200 50,000 34,000 V 55,000,000 5,0,500

19 V Series AC Electrical Data page SINGLE-FIELD CIRCUIT DUAL-FIELD CIRCUIT MODEL NO. & ELEC- TRIC HEATER kw [] VOLT/ PHAS E 0 Hz NO. OF FIELD POW- ER CKTS. MINIMUM CIRCUIT AMPACI- TY MAX FUSE OR HVACR BREAKER SIZE 2 FIELD POW- ER WIRE SIZE [3], [4], [5] GROUN D WIRE SIZE MIN. WIRE AMPACI- TY MAX FUSE OR HVACR BREAKER FIELD POWER WIRE SIZE [3], [4], [5] GROUN D WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 V4B00A / V424B00A / V424B00A / V4B00A / V4B00A 20-2/ V43B00A / V43B00A 5 20/2/ V43B00A 4 5 / V44B00A / V44B00A / V44B00A 5 / VB00B / VB00B / VB00B 5 / () Heater Data were based on 2 or V AC respectively (2) Maximum power recommended size for Time Delay fuse or HACR breaker (5) For single power conductor, sized per NEC Table 3 () Power supply wire minimum 75C rated COPPER CONDUCTOR ONLY (3) Power supply wire size and ground wires were based on AWG 75C rise, NEC Article 3

20 H Series Heat Pump Specifications page 20 HP Model EER 3.0 COP Cooling Heating Capacity (J) Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) H424**A 23,00 23, //0 2. / "/2000 / /0. H424**A3 23,00 23, //0.4 / /2000 / /0. H4**A 2,0 2, //0 / "/2000 / /0.5 H4**A3 2,0 2, /3/0 / "/2000 / /0.5 H43**A 35,000 34, //0 7. / "/2000 / /0.5 H43**A3 35,000 34, /3/0 3.2 / "/2000 / /0.5 H43**A4 35,000 34,000 /3/0.0 / "/2000 / /0.5 H44**A 44,000 45, //0 2.4 / "/00 / /0.20 H44**A3 44,000 45, /3/0 4.5 / "/00 / /0.20 H44**A4 44,000 45,000 /3/0 7. / "/00 / /0.20 H**A 55,000 54, //0 2.3 / "/00 / /0.20 H**A3 55,000 54, /3/0 5. / "/00 / /0.20 H**A4 55,000 54,000 /3/0.7 / "/00 / /0.20 (J) Rated in accordance with ANSI/ARI Standard Standard Ventilation Package (K) Includes factory-installed filters and wet coils Heat Pump Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper H424 5/25% H4 2/25% H43 353/25% H44 425/25% H 45/25% 25"X"X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models H Series Heat Pump Cooling Performance Ambient Temperature Fahrenheit Heat Pump 5 Degrees 0 Degrees Model Total Sensible Total Sensible H424 23,00 7,000 25,200 7,000 H4 2,0 2,0 3,0 22,000 H43 35,000 2,000 37,0 25,000 H44 44,000 34,200 50,000 34,000 H 55,000 3,000 57,0 3,500 H Series Heat Pump Heating Performance Heat Pump Model Ambient Temperature Fahrenheit 47 Degrees 7 Degrees H424 23,00 5,000 H4 2,000,0 H43 34,000 2,000 H44 44,000 27,000 H 55,000 32,000

21 H Series Heat Pump Electrical Data page 2 SINGLE-FIELD CIRCUIT DUAL-FIELD CIRCUIT Model No. & Electric Heater Kw [] VOLT/ PHASE 0 Hz NO. OF FIELD POWER CKTS. MINIMUM CIRCUIT AMPACITY MAX FUSE OR HVACR BREAKER SIZE [2] FIELD POWER WIRE SIZE [3], [4], [5] GROUND WIRE SIZE MINIMUM WIRE AMPACITY MAX FUSE OR HVACR BREAKER [2] FIELD POWER WIRE SIZE [3], [4], [5] GROUND WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 H424B00A / OR H424B00A3 20-2/ H4B00A / OR H4B00A3 20-2/ H43B00A / OR H43B00A3 20-2/ H43B00A4 / H44B00A / OR H44B00A3 20-2/ H44B00A4 / HB00B / OR 2 OR HB00B3 20-2/ HB00B4 / () Heater Data were based on 2 or V AC respectively (2) Maximum power recommended size for Time Delay fuse or HACR breaker (3) Power supply wire size and ground wires were based on AWG 75C rise, NEC Article 3 and Table 3- (4) For single power conductor, sized per NEC Table 3 (5) Power supply wire minimum 75C rated COPPER CONDUCTOR ONLY () Max kw heat with heat pump operation. Full electric heat available in heat mode

22 TV Series AC Specifications page 22 AC Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) TV3S** 33, //0.7 / "/2000 /3 Variable. 250/0.5 TV3T** 33, /3/0.4 / "/2000 /3 Variable. 250/0.5 TV3D** 33,000 /3/0 5.7 / "/2000 /3 Variable.3 250/0.5 TV4S** 44, //0 2. / "/00 /2 Variable /0.20 TV4T** 44, /3/0 3.7 / "/00 /2 Variable /0.20 TV4D** 44,000 /3/0.2 / "/00 /2 Variable. 00/0.20 TV0S** 55, //0 2.3 / "/00 /2 Variable /0.20 TV0T** 55, /3/0 5. / "/00 /2 Variable /0.20 TV0D** 55,000 /3/0 7.7 / "/00 /2 Variable. 20/0.20 (J) Rated in accordance with ANSI/ARI Standard (K) Includes factory-installed filters and wet coils Standard Ventilation Package AC Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper TV3 3/25% TV4 425/25% TV0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models TV Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit AC Model 5 0 Total Sensible Total Sensible TV43 33,000 24,0 35,0 2,0 TV44 44,000 34,000 4,000 37,000 TV 55,000,000 0,000 44,000

23 TV Series AC Electrical Data page 23 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINI- MUM CIRCUIT AM- PACICY MAX OVER CUR- RENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIM WIRE AMPAC- ITY MAX OVER CUR- RENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4], [5] GROUND WIRE SIZE TV3S** 23 2 CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT / TV3T** / TV3D* * / TV4S** / TV4T** / OR TV4D* / TV0S** / TV0T** / OR TV0D* / [] Heater data were based on 2V or V AC respectively. [2] Maximum recommended size for "Time Delay" fuse or HACR circuit breaker. [3] Power supply wire size and ground wire sizez were based on AWG 75C rise, NEC Article 3 and Table 3.5(B)(). [4] For single power conductor, sized per NEC Table 3.5(B)(7). [5] Power supply wire 75C rated COPPER CONDUCTOR ONLY.

24 TH Series Heat Pump Specifications page 24 HP Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) TH3S** 33, //0 5.3 / "/2000 /3 Variable. 250/0.5 TH3T** 33, /3/0. / "/2000 /3 Variable 250/0.5 TH3D** 33,000 /3/0 5.7 / "/2000 /3 Variable.3 250/0.5 TH4S** 44, //0 2.2 / "/00 /2 Variable /0.20 TH4T** 44, /3/0 4 / "/00 /2 Variable /0.20 TH4D** 44,000 /3/0.4 / "/00 /2 Variable. 700/0.20 TH0S** 55, //0 27. / "/00 /2 Variable /0.20 TH0T** 55, /3/0.5 / "/00 /2 Variable /0.20 TH0D** 55,000 /3/0 7.2 / "/00 /2 Variable. 2200/0.20 (J) Rated in accordance with ANSI/ARI Standard (K) Includes factory-installed filters and wet coils Standard Ventilation Package HP Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper TH3 3/25% TH4 425/25% TH0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models TH Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit HP Model 5 0 Total Sensible Total Sensible TH3 33,000 24,0 35,0 2,0 TH4 44,000 32,700 47,000 35,000 TH0 55,000,000 0,000 44,000 TH Series Heat Pump Heating Performance Heat Pump Model Ambient Temperature Fahrenheit 47 Degrees 7 Degrees TH43 32,000,00 TH44 43,500 27,000 TH 52,000 3,000

25 TH Series Heat Pump Electrical Data page 25 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINI- MUM CIRCUIT AM- PACICY MAX OVER CUR- RENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIM WIRE AMPAC- ITY MAX OVER CUR- RENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4], [5] GROUND WIRE SIZE TH3S** 23 2 CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT / 4 50 OR TH3T** / TH3D** / TH4S** OR / OR TH4T** / TH4D** /3 25 TH0S** 0 5 OR / OR TH0T** / TH0D** / [] Heater data were based on 2V or V AC respectively. [2] Maximum recommended size for "Time Delay" fuse or HACR circuit breaker. [3] Power supply wire size and ground wire sizez were based on AWG 75C rise, NEC Article 3 and Table 3.5(B)(). [4] For single power conductor, sized per NEC Table 3.5(B)(7). [5] Power supply wire 75C rated COPPER CONDUCTOR ONLY.

26 SV Series AC Specifications page 2 AC Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) SV3S** 33, //0 5.3 / "/2000 / /0.5 SV3T** 33, /3/0. / "/2000 / /0.5 SV3D** 33,000 /3/0 5.7 / "/2000 / /0.5 SV4S** 43, //0 2.2 / "/00 / /0.20 SV4T** 43, /3/0 4 / "/00 / /0.20 SV4D** 43,500 /3/0.4 / "/00 / /0.20 SV0S** 55, //0 27. / "/00 3/ /0.20 SV0T** 55, /3/0.5 / "/00 3/ /0.20 SV0D** 55,000 /3/0 7.2 / "/00 3/ /0.20 (J) Rated in accordance with ANSI/ARI Standard (K) Includes factory-installed filters and wet coils Standard Ventilation Package AC Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper SV3 3/25% SV4 425/25% SV0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models SV Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit AC Model 5 0 Total Sensible Total Sensible SV3 33,000 24,0 35,500 25,000 SV4 43,500 34,500 50,000 37,000 SV0 55,000,000 0,000 44,000

27 SV Series AC Electrical Data page 27 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINIMUM CIRCUIT AM- PACICY MAX OVER CURRENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIN WIRE AMPACITY MAX OVER CURRENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4],[5] GROUND WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 SV3S** / SV3T** / SV3D** / SV4S** / SV4T** / OR SV4D** / SV0S** / SV0T** / OR SV0D** / [] Heater data were based on 2V or V AC respectively. [2] Maximum recommended size for "Time Delay" fuse or HACR circuit breaker. [3] Power supply wire size and ground wire sizez were based on AWG 75C rise, NEC Article 3 and Table 3.5(B)(). [4] For single power conductor, sized per NEC Table 3.5 (B)(7). [5] Power supply wire 75C rated COPPER CONDUCTOR ONLY.

28 SH Series Heat Pump Specifications page 2 HP Model EER Cooling Capacity (J) Volts/Phase/ Hertz Compressor Rated Load Amps HP Outdoor Fan Data Blower Data Full Load Full Load RPM Amps Fan Dia/CFM HP RPM Amps CFM/ESP (K) SH3S** 33, //0 5.3 /.2 22"/2000 / /0.5 SH3T** 33, /3/0. /.2 22"/2000 / /0.5 SH3D** 33,000 /3/0 5.7 / "/2000 / /0.5 SH4S** 43, //0 2.2 / "/00 / /0.20 SH4T** 43, /3/0 4 / "/00 / /0.20 SH4D** 43,500 /3/0.4 / "/00 / /0.20 SH0S** 55, //0 27. / "/00 3/ /0.20 SH0T** 55, /3/0.5 / "/00 3/ /0.20 SH0D** 55,000 /3/0 7.2 / "/00 3/ /0.20 (J) Rated in accordance with ANSI/ARI Standard (K) Includes factory-installed filters and wet coils Standard Ventilation Package HP Model Max Fresh Air CFM/% (L) Return Air Filter Barometric Filter Barometric Damper SH3 3/25% SH4 425/25% SH0 500/25% 4 or X "X" Disposable 20"X"X" Disposable 7"X2"X/4"Permanent Washable Adjustable Barometric Damper Standard on All Models SH Series Air Conditioner Cooling Performance Ambient Temperature Fahrenheit HP Model 5 0 Total Sensible Total Sensible SH3 33,000 24,0 35,500 25,000 SH4 43,500 34,500 50,000 37,000 SH0 55,000,000 0,000 44,000 SH Series Heat Pump Heating Performance Heat Pump Model Ambient Temperature Fahrenheit 47 Degrees 7 Degrees SH43 2,500 7,500 SH44,000 25,000 SH 52,000 3,000

29 SH Series Heat Pump Electrical Data page 2 SINGLE FIELD CIRCUIT DUAL FIELD CIRCUIT Model No. & Electric Heater Kw [] Volt / Phase No. of Field Power Ckts MINIMUM CIRCUIT AMPACICY MAX OVER CURRENT PROTEC- TION [2] FIELD POWER WIRE SIZE [3], [4],[5] GROUND WIRE SIZE MIM WIRE AMPACITY MAX OVER CUR- RENT PROTECTION [2] FIELD POWER WIRE SIZE [3],[4],[5] GROUND WIRE SIZE CKT CKT2 CKT CKT2 CKT CKT2 CKT CKT2 SH3S** / OR SH3T** / SH3D** / SH4S** OR / OR SH4T** / SH4D** /3 25 SH0S** 0 5 OR / OR SH0T** / SH0D** /3 2 () Heater Data were based on 2 or V AC respectively (2) Maximum power recommended size for Time Delay fuse or HACR breaker (3) Power supply wire size and ground wires were based on AWG 75C rise, NEC Article 3 and Table 3- (4) For single power conductor, sized per NEC Table 3 (5) Power supply wire minimum 75C rated COPPER CONDUCTOR ONLY () Max kw heat with heat pump operation. Full electric heat available in heat mode

30 Looking for Quiet? Look to... S series The Eubank S series Reduces Indoor Sound Documented to as low as.3 decibels (dba)* Quiet and High Efficiency! *Actual sound levels may vary depending on conditions. INNOVATION Same Cabinet Dimensions Same Supply & Return Dimensions Increased Efficiency + EER T Series EER V&H Series

31 Will it Fit? YES! Supply Air Openings - the SAME! Supply Air Opening Return Air Openings - the SAME! Distance between openings - the SAME! Return Air Opening All Eubank units will replace most existing EER or less units of the same tonnage on the market Exact dimensions on pages 5 & of Product Guide Easy to Service? Eubank! Access compressor from the front Access condenser motor and blade from the front Access electrical components from the front Access slide out blowers from the front Coil surface is protected from accidental damage Coil surface is out of direct sunlight to help reduce load

32 Product Guide V & H series V for A/C & H for Heat Pump Standard Efficiency Quick Reference: pages 4, 5 Dimensions: 5 Specifications: pages through 2 T series High Efficiency TV for A/C & TH for Heat Pump Single Step Compressor, ECM Blower Motor Quick Reference: pages, 7 Dimensions: 5 Specifications: pages 22 through 25 S series High Efficiency Low Sound SV for A/C & SH for Heat Pump Two Step Compressor, ECM Blower Motor ECM Condenser Motor, Sound Attenuation Module (SAM) Enhancements to the Cabinet to Minimize Sound Vibrations Quick Reference: pages, Dimensions: Specifications: pages 2 through 2 Product Guide June 207 Eubank is a registered trademark of Airxcel, Inc. Due to manufacturer s policy of continuous product improvement, the manufacturer reserves the right to make changes without notice. All product specifications reflect available information at the printing of this brochure. All rights reserved. Eubank 5 Seedling Drive Cordele, GA Fax

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24A-Q60A Air Conditioners The Q-TEC Series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q-TEC s design provides whisper quiet operation with total

More information

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5

More information

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units Heating Capacities: Cooling Capacities: Q-TEC Q2H3-QH3 Air-to-Air Heat Pump 0 EER Units 23,0 to,000 Btuh,000 to 5,0 Btuh The Q-TEC Series self contained packaged heat pump is designed to be installed inside

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP12-20-24-30-36-42-48-60-72 General

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient

More information

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT HEAT PUMPS EER, (60HZ) THE WALL-MOUNT HEAT PUMPS -. EER, (HZ) Models: Heating Capacities: Cooling Capacities: Engineered Features WHA to WHA Hz (,5 to 5,5 Btuh) (7, to 5, Btuh) The Bard Wall-Mount Heat Pump is a self contained

More information

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps Heating Capacities: 2, to 7, BTUH Capacities:, to 2, BTUH The Q/Tec Series self-contained packaged heat pump is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

Indoor Air Handlers with Compressors MVS and MVW

Indoor Air Handlers with Compressors MVS and MVW Indoor Air Handlers with Compressors MVS60-90-120-144 and MVW60-90-120-144 General Description The Marvair Marine self-contained water and air cooled air conditioners are designed for both new installations

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37,

More information

9-11+ EER 2-5 Ton Vertical Packaged Wall Mount Heat Pumps

9-11+ EER 2-5 Ton Vertical Packaged Wall Mount Heat Pumps PRODUCT DATA SHEET 9-+ EER 2-5 Ton Vertical Packaged Wall Mount Heat Pumps General Description The Eubank WalPac H/P wall mounted heat pumps are the ideal HVAC system for a wide variety of applications.

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners Models AVPA24-30-36-42-48-60-72 (Single Stage Compressor) Models HVEA24-30-36-42-49-60 (Single Stage Compressor) Models HVESA36-42-49-60

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA PRODUCT DATA SHEET DC Free Air HVAC Unit w/48 VDC Evaporator Fan Motor, 00% Free Cooling and CoolLinks Controller Models ASDCA/HSDCA36-42-48-60-72 & ASDCHA36-42-48-60 General Description The Marvair ComPac

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA General Description The Marvair GreenPac and GreenPac HGR (Hot Gas Reheat) air conditioners are complete, factory assembled wall-mounted systems designed to provide total comfort while meeting ventilation

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

RSG16**S1M. Split System Air Conditioner 16 SEER

RSG16**S1M. Split System Air Conditioner 16 SEER RSG16**S1M Split System Air Conditioner 16 SEER COMPRESSOR High-efficiency 2 stage Copeland UltraTechTM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected

More information

Q/Tec TM QA-Series Air Conditioners

Q/Tec TM QA-Series Air Conditioners Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALLMOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS, WAS, WAS to Ton (,0 to,00 Btuh) Right Side Control Panel 0Hz GREEN REFRIGERANT RA The Bard

More information

9-11+ EER 1-6 Ton Vertical Packaged Wall Mount Air Conditioners

9-11+ EER 1-6 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9-+ EER -6 Ton Vertical Packaged Wall Mount Air Conditioners Models: AVPA2-20-24-30-36-42-48-60-72 HVESA36-42-49-60 HVEA24-30-36-42-49-60 AVHA2-20-24-30-36-42-48-60 General Description

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

2 to 5 Ton Vertical Packaged Wall Mount Heat Pumps

2 to 5 Ton Vertical Packaged Wall Mount Heat Pumps 2 to 5 Ton Vertical Packaged Wall Mount Heat Pumps PRODUCT DATA SHEET Models AVPA24 (Single Stage Cooling) HVPA24-30-36-42-49-60 (Single Stage Cooling) HVPSA24-30-36-42-49-60 (2-Stage Cooling) General

More information

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance: Residential & Light Commercial HVAC PTAC/PTHP Packaged Terminal Air Conditioners and Heat Pumps Fedders Packaged Terminal Air Conditioners are designed to fit all 16" H x 42" W wall sleeves. They are the

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN 4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF FORM NO. 4HP15L-100 (12/2018) COILS Omniguard total corrosion protection technology designed coil Enhanced

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Hazardous Location Certified

Hazardous Location Certified Certified. Not Modified. EONA2-72 and EXNDA/EONDA90-240 2,000 BTUH (3.5Kw) to 240,000 BTUH (70.3Kw) Increased Safety Vertical Wall Mount Air Conditioners General Description EXNA60 The old approach to

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Installation & Operation Manual 9-11 EER Vertical Wall-Mount Air Conditioners

Installation & Operation Manual 9-11 EER Vertical Wall-Mount Air Conditioners Air Conditioner Product Manual Vertical Wall-Mount Air Conditioners with Front Control Box Panel Installation & Operation Manual 9-11 EER Vertical Wall-Mount Air Conditioners MODELS: AVPA 12-20-24-30-36-42-48-60-72

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners Bard Manufacturing's revolutionary MEGA-TEC WALL-MOUNT sets the industry standard for flexibility. Engineered to cool virtually any equipment building

More information

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0%

More information