WOLF VENTILATION SYSTEM PRICE LIST

Size: px
Start display at page:

Download "WOLF VENTILATION SYSTEM PRICE LIST"

Transcription

1 VENTILATION SYSTEM PRICE LIST JANUARY m 3 /h

2 THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation projects alike. The WOLF range of control units can meet any demand for a perfect indoor environment. All equipment is easy to operate, highly energy efficient and reliable. Solar thermal systems can be swiftly integrated into existing systems. WOLF equipment is easy and quick to install and maintain. The prices mentioned are ex-works Mainburg, and do not include packaging or value-added tax. They are based on our conditions of sale and delivery. Subject to changes. The illustrations correspond approximately to the actual versions of the articles. This picture Serves, above all, the faster and better search and identification of the required product.

3 VENTILATION SYSTEM PRICE LIST JANUARY LH-EC / LH / LH-ATEX UNIT HEATER 02 TLH-EC / TLH TOPWING UNIT HEATER 03 TLHK-EC / TLHK TOPWING UNIT HEATER 04 LHD UNIT HEATER 05 TLHD-EC / TLHD-K-EC / TLHD / TLHD-K TOPWING UNIT HEATER 06 TL-2 WARM AIR CURTAIN UNIT 07 LD 15 CEILING FAN 08 ER SMOKE EXTRACT FANS 09 DV-2 ROOF EXTRACT FANS 10 CWL / CWL-D COMFORT HOME VENTILATION SYSTEM 11 CGL COMFORT LARGE AREA VENTILATION UNITS 12 CFL COMFORT FLAT VENTILATION UNIT 13 CKL COMPACT COMFORT VENTILATION UNIT 14 COMFORT SWIMMING POOL UNIT 15 CRL COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT WOLF

4

5 01 WOLF LH-EC / LH / LH-ATEX UNIT HEATER BASIC UNITS 2 LH-EC Air heater with EC fan 2 LH Air heater 3 WRS CONTROL SYSTEMS / CONTROL ACCESSO- RIES LH-ATEX BASIC UNITS 7 LH-ATEX Air heater in explosion-proof design 7 LH-ATEX CONTROL SYSTEMS 8 LH-EC / LH / LH-ATEX ACCESSORIES 9 CONNECTING ACCESSORIES 9 DEVICE FASTENINGS 11 DISCHARGE ACCESSORIES 13 INTAKE ACCESSORIES 15 SWITCHING DEVICES 16 SERVOMOTORS 18 THERMOSTATS / TERMINAL BOX 19 TECHNICAL DATA 20 BASIC UNIT 20 ACCESSORIES WOLF

6 01 LH-EC AIR HEATER WITH EC FAN RG L50 Air heater with discharge louvre for wall or ceiling mounting; outdoor air, mixed air or recirculation air mode for heating or ventilation. Full motor protection with integral temperature monitoring Energy saving EC fans (1 x 230 V) Casing: Zinc-plated sheet steel Discharge louvre: WOLF silver EC-motor 230V / 50Hz Heat exchanger: Copper-aluminium Type 1 Type 2 Type 3 Type 4 Type D * Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 EC-motor 230V / 50Hz Heat exchanger: Galvanised steel Type 1 Type 2 Type Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Type D * Type D * AF horizontal AF vertical Art. no , , , ,00 Art. no , , , ,00 * Note: With unit heater LH-EC in combination with electrical or steam coil, controller by request! WOLF BASIC UNITS

7 01 LH AIR HEATER RG L50 Air heater with discharge louvre for wall or ceiling mounting; outdoor air, mixed air or recirculation air mode for heating or ventilation. Single phase AC motor 230 V / 50 Hz Three-phase motor: 3 x 400 V / 50 Hz Casing: Zinc-plated sheet steel Discharge louvre: WOLF silver Single phase AC motor 230V / 50Hz Heat exchanger: Copper-aluminium Type 1 Type 2 Type 3 Type 4 Type D * Art. no , , ,00 Art. no , , ,00 Art. no , , ,00 Art. no , , ,00 Art. no , , ,00 Single phase AC motor 230V / 50Hz Heat exchanger: Galvanised steel Type 1 Type 2 Type Art. no , , ,00 Art. no , , ,00 Art. no , , ,00 Type D * Type D * AF horizontal AF vertical Art. no , , ,00 Art. no , , , WOLF BASIC UNITS

8 01 Three-phase motor 3 x 400V / 50Hz Heat exchanger: Copper-aluminium Type 1 Type 2 Type 3 Type 4 Type D * Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Three-phase motor 3 x 400V / 50Hz Heat exchanger: Galvanised steel Type 1 Type 2 Type Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Type D * Type D * AF horizontal AF vertical Art. no , , , ,00 Art. no , , , ,00 Three-phase motor 3 x 400V / 50Hz Heat exchanger: Electrical (incl. safety limiter) * 25 2 x 3kW = 6kW 3 x 3kW = 9kW 4 x 3kW = 12kW 2 x 3kW = 6kW 3 x 3kW = 9kW 4 x 3kW = 12kW AF horizontal AF horizontal AF horizontal AF vertical AF vertical AF vertical Art. no ,00 Art. no ,00 Art. no ,00 Art. no ,00 Art. no ,00 Art. no ,00 Three-phase motor 3 x 400V / 50Hz Heat exchanger: without heat exchangers Art. no * Note: With unit heater LH in combination with electrical or steam coil, controller by request! 605,00 770,00 965, , WOLF BASIC UNITS

9 WRS CONTROL SYSTEMS 01 Art. no. DG BML VENTILATION PROGRAMMING UNIT Room temperature-compensated temperature control Graphic display with backlight Simple menu navigation through plain text display Operation using rotary knob with push-function 4 function keys for frequently used functions (information, temperature, speed setting, fresh air proportion) Mounted optionally in the ventilation module or in the wall holder as remote control Only one ventilation operating module BML is needed to operate up to 7 zones Demand-optimised boiler water temperature demand via ebus ebus interface L50 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 LM1 VENTILATION MODULE (incl. room temperature sensor) Ventilation module for controlling unit heaters with two-stage motor Simple configuration of the controller by selecting predefined system diagrams Demand-optimised room temperature control via the rotary speed of the unit heater Operation of the heating circuit pump Operation of the heat generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on L50 Note: Not in conjunction with EC motor. LM2 VENTILATION MODULE Ventilation module LM2 for controlling the room temperature by means of the rotation speed or the mixer control 2-stage motor control in connection with ventilation module LM1 or variable speed control via EC-motor Simple configuration of the controller by selecting predefined system diagrams Operation of the heat or cooling generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Mixed air flap control Induction louvre control L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

10 01 WOLF CONTROL ACCESSORIES Art. no. DG OUTSIDE, CEILING OR ROOM TEMPERATURE SENSOR H41 DIFFERENTIAL PRESSURE SWITCH For filter monitoring Loose L50 Fitted L50 5-STAGE SWITCH Electronic 5-stage speed controller, input 0-10V (2A, 400V) L50 (4A, 400V) L50 (6A, 230V) L50 Note: Not in conjunction with EC motor. TEMPERATURE SENSOR (NTC 5K, Ø 6MM) LOOSE can be used as a cylinder, boiler, central unit and supply air temperature sensor H41 SENSOR HOLDER For supply air sensor L50 ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

11 01 LH-ATEX AIR HEATER IN EXPLOSION-PROOF DESIGN RG L50 Air heater in explosion-proof design for Zone 2 explosion risk areas (II 3G c IIB T4 X) (II 3G c IIB T4 X). Air heater with discharge louvre for wall or ceiling mounting. Outdoor air, mixed air or recirculation air mode for heating or ventilation. Discharge louvre: WOLF silver Three-phase motor: 3 x 400 V / 50 Hz, 2-stage Δ/Y Full motor protection with built-in thermistors Casing: Zinc-plated sheet steel Three-phase motor 3 x 400V / 50Hz Heat exchanger: Copper-aluminium Type 1 Type 2 Type 3 Type Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Three-phase motor 3 x 400V / 50Hz Heat exchanger: Galvanised steel Type 1 Type 2 Type Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 RAL and special colours by request WOLF LH-ATEX BASIC UNITS

12 01 WOLF LH-ATEX CONTROL SYSTEMS Art. no. DG EXPLOSION-PROOF ATEX TERMINAL BOX Fitted and wired L50 THERMISTOR TRIGGERING UNIT Suitable for installation in control panel on site L50 Note: The thermistor triggering unit may only be installed outside the potentially explosive area. A1Ü CONTROL UNIT Without explosion-proof switch (only suitable for 1 unit) L50 Note: Only possible in conjunction with LH 40,63,100-ATEX. Installation only outside potentially explosive area. EXPLOSION-PROOF SWITCH For A1 Ü controller, operating voltage 690V, max. current 16A (4A), IP rating IP L WOLF LH-ATEX BASIC UNITS

13 CONNECTING ACCESSORIES 01 for product Art. no. DG SHUT-OFF SETS FOR HEAT EXCHANGER FOR FLOW AND RETURN Consisting of: 1 threaded connection for connecting to flow and return with flat gasket, automatic air vent valve, drain and fill valve, ball valves with 1 female thread in flow and return, ¾ male thread connection option (e.g. for the thermometer) in flow and return, suitable for heating water temperatures up to max. 110 C and operating pressure up to max. 10bar. Straight-through version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100, LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40; TLHD-EC, TLHD-K-EC, TLHD, TLHD-K Right angle version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100 LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L50 HYDRONIC BALANCING VALVE DN20, 4-15 l/min L50 DN20, 8-30 l/min L50 DN25, 6-20 l/min L50 DN25, l/min L50 DN32, l/min L50 DN40, l/min L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

14 01 WOLF CONNECTING ACCESSORIES for product Art. no. DG FLANGE SET Consisting of 2 threaded flanges, 2 welded flanges and 2 flat gaskets, plus hexagonal bolts and hexagonal nuts DN20, R ¾ LH-EC/LH 25, 40 Type 1; LH 25,40-ATEX Type 1; TLH-EC/TLH 25,40 Type 1 DN25, R 1 LH-EC/LH 25,40 Type 2/3/4; LH 25/40-ATEX Type 2/3/4; LH-EC/LH 63,100 Type 1; LH 63/100-ATEX Type 1; TLH-EC/TLH 25,40 Type 2/3/4; TLH-EC/TLH 63,100 Type 1; DN32, R 1¼ DN40, R 1½ TLHK 25, 40; LHD LH-EC/LH 63, Type 2/3/4; LH 63-ATEX Type 2/3/4; TLH-EC/TLH 63 Type 2/3/4; TLHK 63 LH-EC/LH 63, Type 2/3/4; LH 63-ATEX Type 2/3/4; TLH-EC/TLH 63 Type 2/3/4; TLHK L L L L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

15 DEVICE FASTENINGS 01 for product Art. no. DG FIXING BRACKETS For installation on the wall or ceiling, made from 2mm folded sheet steel, zinc-plated Consisting of: - 2 brackets - Hexagon bolts for installing on appliance unit size 25, L50 unit size 63, L50 FIXING KIT FOR CONCRETE LINTEL, VERTICAL For fixing to a concrete beam by suspending from pre-mounted fixing rails. Consisting of: Mounting rail, 2 support rails, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 FIXING KIT FOR STEEL BEAM, VERTICAL For fixing to a steel beam by suspending from pre-mounted fixing rails with clamping claws. Suitable for all steel beams with a flange width of 100mm to 300mm and a flange thickness of 6 mm to 21 mm. Consisting of: Mounting rail, 2 support rails, 4 clamping claws, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 FIXING KIT FOR STEEL BEAM, HORIZONTAL AND INCLINED WITHOUT INCLINATION COMPENSATI- ON For fixing to a horizontal or inclined steel beam with a flange width of 100mm to 300mm and a flange thickness of 6mm to 21mm. Consisting of: 2 support rails, 4 clamping claws, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 Attention: Before using the fixing kits, check and factor in the static regulations of the on-site concrete pillars or steel beams. Installation only with standard units with an overall depth of 300 mm WOLF LH-EC / LH / LH-ATEX ACCESSORIES

16 01 WOLF DEVICE FASTENINGS for product Art. no. DG FIXING KIT FOR STEEL BEAM, INCLINED WITH IN- CLINATION COMPENSATION For fixing to a steel beam with a flange width of 100mm to 300mm and a flange thickness of 6mm to 21mm. Consisting of: 2 support rails, 4 clamping claws, 4 self-aligning brackets, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 MOUNTING BRACKET For installing the appliance on the wall or ceiling with fitted mixed air box, recirculation air box, outdoor air box or filter box. Zinc-plated sheet steel 4 mounting brackets are required for fastening. These are included with the corresponding intake accessories. (Sealing against the wall/ceiling on site). 1 pce L50 2-pce set L50 4-pce set L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

17 DISCHARGE ACCESSORIES 01 for product Art. no. DG DISCHARGE CONE For increasing the throw when the unit is installed at he ight. Zinc-plated sheet steel unit size L50 unit size L50 unit size L50 unit size L50 DISCHARGE NOZZLE For a large throw, suitable as air curtain at doors. Discharge temperature for air curtain approx C above room temperature. Zinc-plated sheet steel unit size L50 unit size L50 unit size L50 unit size L50 FOUR-WAY DISCHARGE With adjustable air guide fins, suitable for heating low rooms with steady air distribution to all four sides. Zinc-plated sheet steel. Fins in WOLF silver, similar to RAL unit size L50 unit size L50 unit size L50 unit size L50 WIDE SPREAD DISCHARGE For greater lateral spread of the warm air stream. Air jet cone up to approx. 120 ; horizontal and vertical fins individually adjustable. Powder-coated, colour: WOLF silver, similar to RAL unit size L50 unit size L50 unit size L50 unit size L50 DISCHARGE CROSS (LOOSE) Improvement of the air circulation and temperature distribution through thorough mixing of the warm air stream with the indoor air. The reduced temperature of the warm air stream increases the throw. Reduces the air temperature in the ceiling area, thus reducing ventilation and transmission heat losses; energy saving up to 15%. unit size L50 unit size L50 unit size L50 unit size L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

18 01 WOLF DISCHARGE ACCESSORIES for product Art. no. DG ADAPTOR CONE FOR INDUCTION LOUVRE For increasing the throw in halls with high ceilings, in which the maximum installed height of the ceiling units with induction louvre alone is not sufficient. Zinc-plated sheet steel. Required size of the induction louvre: For LH63 adaptor cone: LH25 induction louvre unit size L50 For LH100 adaptor cone: LH40 induction louvre unit size L50 INDUCTION LOUVRE FOR WALL MOUNTED UNIT Manual setting LH-EC/LH 25, L50 LH 25-ATEX LH-EC/LH 40, L50 LH 40-ATEX LH-EC/LH 63, L50 LH 63-ATEX LH-EC/LH 100, L50 LH 100-ATEX With 230 V / 50 Hz electric servomotor LH-EC/LH L50 fitted LH-EC/LH L50 LH-EC/LH L50 With 24 V ~ electric servomotor fitted LH-EC/LH L50 LH-EC/LH L50 LH-EC/LH L50 LH-EC/LH L50 LH-EC/LH L50 INDUCTION LOUVRE FOR CEILING UNIT Manual setting LH-EC/LH 25, L50 LH 25-ATEX LH-EC/LH 40, L50 LH 40-ATEX LH-EC/LH 63, L50 LH 63-ATEX LH-EC/LH 100, L50 LH 100-ATEX With 230 V / 50 Hz electric servomotor LH-EC/LH L50 fitted LH-EC/LH L50 LH-EC/LH L50 With 24 V ~ electric servomotor fitted LH-EC/LH L50 LH-EC/LH L50 LH-EC/LH L50 LH-EC/LH L50 LH-EC/LH L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

19 INTAKE ACCESSORIES 01 for product Art. no. DG MIXING BOX For individual adjustment of the outdoor air flow rate. Outdoor air intake at the back, recirculation air intake at the side or, when mixed air box is rotated by 90, from above Variable manual adjustment between pure recirculation air mode via mixed air to pure outdoor air mode. Zinc-plated sheet steel. Mounting bracket as standard. Alternatively: Servomotor 230V variable speed (part no ) or in conjunction with LM2 ventilation module Servomotor 24V variable speed (part no ) LH-EC/LH 25 LH-EC/LH 40 LH-EC/LH 63 LH-EC/LH 100 on request on request on request on request Note: If used in outdoor air mode, air heaters are covered by the scope of application of EU Regulation 1253/2014. ATEX MIXING BOX Zinc-plated sheet steel Louvre dampers with bronze bearing LH-ATEX on request RECIRCULATION AIR BOX WITH LATERAL INTAKE For recirculation air intake through two grilles at the side or, when rotated by 90, intake from top and bottom. Zinc-plated sheet steel. Mounting bracket as standard. unit size L50 unit size L50 unit size L50 unit size L50 FILTER BOX With filter element as dust trap in outdoor air and mixed air modes, filter category G4. Mounting brackets on request. Zinc-plated sheet steel unit size L50 unit size L50 unit size L50 unit size L50 FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME unit size L50 unit size L50 unit size L50 unit size L50 Note: In combination with LH-ATEX, an earth strap is required for equipotential bonding (part no ) WOLF LH-EC / LH / LH-ATEX ACCESSORIES

20 01 WOLF SWITCHING DEVICES for product Art. no. DG VARIABLE SPEED CONTROLLER For variable operation of one or more unit heaters with EC motor (0-10V) LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L50 1-STAGE SWITCH D1-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 2-STAGE SWITCH DS-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 3-STAGE SWITCH E 3-7T Full motor protection switch (7A, 230V) with lock preventing unintentional restart LH, TLH L50 3-STAGE SWITCH D 3-4 Full motor protection switch (4A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 5-STAGE SWITCH D5... Full motor protection switch with lock preventing unintentional restart D5-1 (1A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-3 (2A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-7 (4A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-12 (7A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-19 (12A, 400V) LH, LH-ATEX, TLH, TLHD, TLHD-K L L L L L54 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. 5-STAGE SWITCH E5-7T Full motor protection switch (7A, 230V) with lock preventing unintentional restart LH, TLH L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

21 SWITCHING DEVICES 01 for product Art. no. DG OMNIPOLAR REPAIR SWITCH AR8 Fitted and wired LH-EC, LH L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

22 01 WOLF SERVOMOTORS for product Art. no. DG A1 AUTOMATIC RELAY For servomotor open/close (3.15A, 230V) LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 A1S AUTOMATIC RELAY For servomotor, variable speed with built-in position indicator (0 to 100 %) (3.15A, 230V) LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TL- HD, TLHD-K L50 24V VARIABLE SPEED SERVOMOTOR FOR MIXED AIR DAMPER In conjunction with LM2 ventilation module LH-EC, LH, TLH-EC, TLH L50 24V SERVOMOTOR FOR OPENING/CLOSING THE OUTDOOR AIR DAMPER LH-EC, LH, TLH-EC, TLH L50 230V / 50HZ SERVOMOTOR FOR OPENING/CLO- SING THE DAMPER LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ACTUATOR, 230V / 50HZ, STEPLESS FOR MIXED AIR DAMPER LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 POSITION INDICATOR For installation on the control panel front for variable speed servomotor activation in conjunction with automatic relay A1 For surface mounting for variable speed servomotor activation in conjunction with automatic relay A1 LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L50 BUTTON FOR SERVOMOTOR (230V / 50HZ) For induction louvre LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK L WOLF LH-EC / LH / LH-ATEX ACCESSORIES

23 THERMOSTATS / TERMINAL BOX 01 for product Art. no. DG ROOM THERMOSTAT LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT WITH SUMMER/WINTER SWITCH LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT CLOCK WITH 7-DAY PRO- GRAM LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 REMOTE SENSOR FOR ROOM THERMOSTAT CLOCK LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT, INDUSTRIAL VERSION LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 FROST STAT, FITTED LH-EC/LH 25, 40, 63; TLH-EC/TLH 25, 40, 63; TLHK-EC/TLHK 25, 40, 63 LH-EC/LH 100, TLH-EC/TLH 100, TLHK-EC/TLHK L L50 UNIVERSAL TIMER WITH 7-DAY PROGRAM LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L50 EARTH STRAP FOR EQUIPOTENTIAL BONDING LH-EC, LH, LH-ATEX, TLH-EC, TLH, TLHK-EC, TLHK L50 INTERMEDIATE TERMINAL BOX FOR PARALLEL OPERATION UP TO 3 UNITS LH, LH-ATEX, TLH, LHD L50 Note: In combination with LH-ATEX, mounting only outside the explosion risk area WOLF LH-EC / LH / LH-ATEX ACCESSORIES

24 01 WOLF BASIC UNIT a b c STANDARD UNIT DIMENSIONS Type Unit size a mm b mm c mm a øe c d b CONNECTIONS LH , TYPE 1-4, COPPER/ALUMINIUM Type Unit size /-3/ /-3/ /-3/ /-3/-4 a mm b mm c mm d mm Øe mm ¾ 1 ¾ 1 1 1¼ 1 1½ a øe c d b CONNECTIONS LH , TYPE 1-3, GALVANISED STEEL Type Unit size /-3/ /-3/ /-3/ /-3/-4 a mm b mm c mm d mm Øe mm ¾ 1 ¾ 1 1 1¼ 1 1½ WOLF TECHNICAL DATA

25 BASIC UNIT 01 a øe c d øf b CONNECTIONS LH , TYPE STEAM, COPPER/ALUMINIUM Type Unit size a mm b mm c mm d mm Øe mm DN40 DN40 DN50 DN50 Øf mm DN20 DN20 DN25 DN WOLF TECHNICAL DATA

26 01 WOLF ACCESSORIES a e c d x x b x x g f h i Ø10 Ø21 FIXING BRACKETS Type Unit size a mm b mm c mm 380 2x d mm e mm f mm 170 2x170 3x170 3x170 g mm h mm i mm b t FIXING KIT FOR STEEL BEAM, VERTICAL b mm t mm 6-21 a b c MOUNTING BRACKET Type Unit size a mm b mm c mm WOLF TECHNICAL DATA

27 c WOLF ACCESSORIES 01 c d a b DISCHARGE CONE Type Unit size a mm b mm c mm d mm d e a a DISCHARGE NOZZLE Type Unit size a mm b mm c mm d mm e mm b c a FOUR-WAY DISCHARGE Type Unit size a mm b mm c mm WOLF TECHNICAL DATA

28 01 WOLF ACCESSORIES e c d a b ADAPTOR CONE FOR INDUCTION LOUVRE Type Unit size a mm b mm c mm d mm e mm a e b d c INDUCTION LOUVRE FOR WALL MOUNTED UNIT Type Unit size a mm b mm c mm d mm e mm a c b d e INDUCTION LOUVRE FOR CEILING UNIT Type Unit size a mm b mm c mm d mm e mm WOLF TECHNICAL DATA

29 01 d a a WOLF ACCESSORIES b c e MIXING BOX Type Unit size a mm b mm c mm d mm e mm b c RECIRCULATION AIR BOX WITH LATERAL INTAKE Type Unit size a mm b mm c mm a b c FILTER BOX Type Unit size a mm b mm c mm a FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Type Unit size a mm WOLF TECHNICAL DATA

30 01 WOLF NOTES WOLF LH-EC / LH / LH-ATEX UNIT HEATER

31 02 WOLF TLH-EC / TLH TOPWING UNIT HEATER TOPWING 2 TOPWING TLH-EC TOPWING TLH TopWing air heater with EC fan TopWing air heater WRS CONTROL SYSTEMS / CONTROL ACCESSORIES 4 WRS CONTROL SYSTEMS 4 CONTROL ACCESSORIES 5 TLH-EC / TLH ACCESSORIES 6 CONNECTING ACCESSORIES 6 DEVICE FASTENINGS 8 DISCHARGE ACCESSORIES 10 INTAKE ACCESSORIES 12 SWITCHING DEVICES 13 SERVOMOTORS 15 THERMOSTATS / TERMINAL BOX 16 TECHNICAL DATA 17 BASIC UNIT 17 ACCESSORIES WOLF

32 02 TOPWING TLH-EC TOPWING AIR HEATER WITH EC FAN RG L50 Air heater with discharge louvre for wall or ceiling mounting; outdoor air, mixed air or recirculation air mode for heating or ventilation Full motor protection with integral temperature monitoring Energy saving EC fans (1 x 230V) Casing: traffic white RAL 9016 Discharge louvre: WOLF silver EC-motor 230V / 50Hz Heat exchangers*: copper-aluminium LPHW Type 1 Type 2 Type 3 Type Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 * Heat exchanger galvanised steel, steam by request. RAL and special colours by request WOLF TOPWING

33 02 TOPWING TLH TOPWING AIR HEATER RG L50 Air heater with discharge louvre for wall or ceiling mounting; outdoor air, mixed air or recirculation air mode for heating or ventilation Discharge louvre: WOLF silver full motor protection through integral thermal contacts Casing: traffic white RAL 9016 Single phase AC motor 230V / 50Hz Heat exchangers*: copper-aluminium LPHW Type 1 Type 2 Type 3 Type Art. no , , ,00 Art. no , , ,00 Art. no , , ,00 Art. no , , ,00 Three-phase motor 3 x 400V / 50Hz Heat exchangers*: copper-aluminium LPHW Type 1 Type 2 Type 3 Type Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 Art. no , , , ,00 * Heat exchanger galvanised steel, steam by request. RAL and special colours by request WOLF TOPWING

34 02 WOLF WRS CONTROL SYSTEMS BML VENTILATION PROGRAMMING UNIT Room temperature-compensated temperature control Graphic display with backlight Simple menu navigation through plain text display Operation using rotary knob with push-function 4 function keys for frequently used functions (information, temperature, speed setting, fresh air proportion) Mounted optionally in the ventilation module or in the wall holder as remote control Only one ventilation operating module BML is needed to operate up to 7 zones Demand-optimised boiler water temperature demand via ebus ebus interface Art. no. DG L50 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 LM1 VENTILATION MODULE (incl. room temperature sensor) Ventilation module for controlling unit heaters with two-stage motor Simple configuration of the controller by selecting predefined system diagrams Demand-optimised room temperature control via the rotary speed of the unit heater Operation of the heating circuit pump Operation of the heat generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Note: Not in conjunction with EC motor L50 LM2 VENTILATION MODULE Ventilation module LM2 for controlling the room temperature by means of the rotation speed or the mixer control 2-stage motor control in connection with ventilation module LM1 or variable speed control via EC-motor Simple configuration of the controller by selecting predefined system diagrams Operation of the heat or cooling generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Mixed air flap control Induction louvre control L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

35 CONTROL ACCESSORIES Art. no. DG OUTSIDE, CEILING OR ROOM TEMPERATURE SENSOR H41 02 DIFFERENTIAL PRESSURE SWITCH For filter monitoring Loose L50 Fitted L50 5-STAGE SWITCH Electronic 5-stage speed controller, input 0-10V (2A, 400V) L50 (4A, 400V) L50 (6A, 230V) L50 Note: Not in conjunction with EC motor. TEMPERATURE SENSOR (NTC 5K, Ø 6MM) LOOSE can be used as a cylinder, boiler, central unit and supply air temperature sensor H41 SENSOR HOLDER For supply air sensor L50 ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

36 02 WOLF CONNECTING ACCESSORIES SHUT-OFF SETS FOR HEAT EXCHANGER FOR FLOW AND RETURN Consisting of: 1 threaded connection for connecting to flow and return with flat gasket, automatic air vent valve, drain and fill valve, ball valves with 1 female thread in flow and return, ¾ male thread connection option (e.g. for the thermometer) in flow and return, suitable for heating water temperatures up to max. 110 C and operating pressure up to max. 10bar. for product Art. no. DG Straight-through version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100, LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40; TLHD-EC, TLHD-K-EC, TLHD, TLHD-K Right angle version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100 LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L50 HYDRONIC BALANCING VALVE DN20, 4-15 l/min L50 DN20, 8-30 l/min L50 DN25, 6-20 l/min L50 DN25, l/min L50 DN32, l/min L50 DN40, l/min L WOLF TLH-EC / TLH ACCESSORIES

37 CONNECTING ACCESSORIES FLANGE SET Consisting of 2 threaded flanges, 2 welded flanges and 2 flat gaskets, plus hexagonal bolts and hexagonal nuts for product Art. no. DG 02 DN20, R ¾ LH-EC/LH 25, 40 Type 1; LH 25,40-ATEX Type 1; TLH-EC/TLH 25,40 Type 1 DN25, R 1 LH-EC/LH 25,40 Type 2/3/4; LH 25/40-ATEX Type 2/3/4; LH-EC/LH 63,100 Type 1; LH 63/100-ATEX Type 1; TLH-EC/TLH 25,40 Type 2/3/4; TLH-EC/TLH 63,100 Type 1; DN32, R 1¼ DN40, R 1½ TLHK 25, 40; LHD LH-EC/LH 63, Type 2/3/4; LH 63-ATEX Type 2/3/4; TLH-EC/TLH 63 Type 2/3/4; TLHK 63 LH-EC/LH 63, Type 2/3/4; LH 63-ATEX Type 2/3/4; TLH-EC/TLH 63 Type 2/3/4; TLHK L L L L WOLF TLH-EC / TLH ACCESSORIES

38 02 WOLF DEVICE FASTENINGS FIXING BRACKETS For installation on the wall or ceiling, made from 2mm folded sheet steel, powder-coated, colour: traffic white RAL Consisting of: - 2 brackets - Hexagon bolts for installing on appliance for product Art. no. DG unit size 25, L50 unit size 63, L50 FIXING KIT FOR CONCRETE LINTEL, VERTICAL For fixing to a concrete beam by suspending from pre-mounted fixing rails. Consisting of: Mounting rail, 2 support rails, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 FIXING KIT FOR STEEL BEAM, VERTICAL For fixing to a steel beam by suspending from pre-mounted fixing rails with clamping claws. Suitable for all steel beams with a flange width of 100mm to 300mm and a flange thickness of 6mm to 21mm. Consisting of: Mounting rail, 2 support rails, 4 clamping claws, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 FIXING KIT FOR STEEL BEAM, HORIZONTAL AND INCLINED WITHOUT INCLINATION COMPENSATI- ON For fixing to a horizontal or inclined steel beam with a flange width of 100mm to 300mm and a flange thickness of 6mm to 21mm. Consisting of: 2 support rails, 4 clamping claws, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel Attention: Before using the fixing kits, check and factor in the static regulations of the on-site concrete pillars or steel beams. Installation only with standard units with an overall depth of 300mm. unit size L50 unit size L WOLF TLH-EC / TLH ACCESSORIES

39 FIXING KIT FOR STEEL BEAM, INCLINED WITH IN- CLINATION COMPENSATION For fixing to a steel beam with a flange width of 100mm to 300mm and a flange thickness of 6mm to 21mm. Consisting of: 2 support rails, 4 clamping claws, 4 self-aligning brackets, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel WOLF DEVICE FASTENINGS for product Art. no. DG unit size L50 unit size L50 02 SUSPENSION TAB FOR APPLIANCE MOUNTING Powder-coated, colour: traffic white RAL 9016 Suitable for installation with threaded rods or perforated strip for configurations with horizontal air routing. 1 Set = 4 items L50 MOUNTING BRACKET FOR INTAKE ACCESSO- RIES, LOOSE For installing the appliance on the wall or ceiling with fitted mixed air box, recirculation air box, outdoor air box or filter box. Powder-coated, colour: traffic white RAL mounting brackets are required for fastening. These are included with the corresponding intake accessories. (Sealing against the wall/ceiling on site). 1 pce L50 4-pce set L WOLF TLH-EC / TLH ACCESSORIES

40 02 WOLF DISCHARGE ACCESSORIES DISCHARGE CONE For increasing the throw when the unit is installed at height. Powder-coated, colour: traffic white RAL for product Art. no. DG unit size L50 unit size L50 unit size L50 unit size L50 DISCHARGE NOZZLE For a large throw, suitable as air curtain at doors. Discharge temperature for air curtain approx C above room temperature. Powder-coated, colour: traffic white RAL unit size L50 unit size L50 unit size L50 unit size L50 FOUR-WAY DISCHARGE With adjustable air guide fins, suitable for heating low rooms with steady air distribution to all four sides. Powder-coated, colour: traffic white RAL Fins in WOLF silver, similar to RAL unit size L50 unit size L50 unit size L50 unit size L50 WIDE SPREAD DISCHARGE For greater lateral spread of the warm air stream. Air jet cone up to approx. 120 ; horizontal and vertical fins individually adjustable. Powder-coated, colour: WOLF silver, similar to RAL unit size L50 unit size L50 unit size L50 unit size L50 INDUCTION LOUVRE FOR WALL MOUNTED UNIT With secondary air cone in traffic white RAL 9016 Manual setting unit size L50 unit size L50 unit size L50 unit size L50 With 230V~ electric servomotor fitted With 24V~ electric servomotor fitted unit size L50 unit size L50 unit size L50 unit size L50 unit size L50 unit size L50 unit size L50 unit size L WOLF TLH-EC / TLH ACCESSORIES

41 INDUCTION LOUVRE FOR CEILING UNIT With secondary air cone in traffic white RAL 9016 WOLF DISCHARGE ACCESSORIES for product Art. no. DG 02 Manual setting unit size L50 unit size L50 unit size L50 unit size L50 With 230V~ electric servomotor fitted With 24V~ electric servomotor fitted unit size L50 unit size L50 unit size L50 unit size L50 unit size L50 unit size L50 unit size L50 unit size L WOLF TLH-EC / TLH ACCESSORIES

42 02 WOLF INTAKE ACCESSORIES MIXING BOX/THERMALLY INSULATED MIXING BOX Mixed air box in thermally insulated version to prevent the formation of condensate. For individual adjustment of the outdoor air flow rate. Outdoor air intake at the back, recirculation air intake at the side or, when mixed air box is rotated by 90, from above/below. Variable manual adjustment between pure recirculation air mode via mixed air to pure outdoor air mode. Powder-coated, colour: traffic white RAL Mounting bracket as standard. for product Art. no. DG Without thermal insulation unit size 25 on request unit size 40 on request unit size 63 on request unit size 100 on request With thermal insulation unit size 25 on request unit size 40 on request unit size 63 on request unit size 100 on request Note: If used in outdoor air mode, air heaters are covered by the scope of application of EU Regulation 1253/2014. RECIRCULATION AIR BOX WITH LATERAL INTAKE For recirculation air intake through two grilles at the side or, when rotated by 90, intake from top and bottom. Powder-coated, colour: traffic white RAL Mounting bracket as standard. unit size L50 unit size L50 unit size L50 unit size L50 FILTER BOX With filter element as dust trap in outdoor air and mixed air modes, filter category G4 for model size 63 and G3 for model size 25/40/100. Mounting bracket on request. Powder-coated, colour: traffic white RAL unit size L50 unit size L50 unit size L50 unit size L50 FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Note: In combination with LH-ATEX, an earth strap is required for equipotential bonding (part no ). unit size L50 unit size L50 unit size L50 unit size L WOLF TLH-EC / TLH ACCESSORIES

43 VARIABLE SPEED CONTROLLER For variable operation of one or more unit heaters with EC motor (0-10V) for product Art. no. DG LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL WOLF SWITCHING DEVICES L STAGE SWITCH D1-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 2-STAGE SWITCH DS-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 3-STAGE SWITCH D 3-4 Full motor protection switch (4A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 5-STAGE SWITCH D5... Full motor protection switch with lock preventing unintentional restart D5-3 (2A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-7 (4A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-12 (7A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-1 (1A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-19 (12A, 400V) LH, LH-ATEX, TLH, TLHD, TLHD-K L L L L L54 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. 3-STAGE SWITCH E 3-7T Full motor protection switch (7A, 230V) with lock preventing unintentional restart LH, TLH L50 5-STAGE SWITCH E5-7T Full motor protection switch (7A, 230V) with lock preventing unintentional restart LH, TLH L WOLF TLH-EC / TLH ACCESSORIES

44 02 WOLF SWITCHING DEVICES OMNIPOLAR REPAIR SWITCH AR8 Loose for product Art. no. DG TLH-EC, TLH L WOLF TLH-EC / TLH ACCESSORIES

45 A1 AUTOMATIC RELAY For servomotor open/close (3.15A, 230V) for product Art. no. DG LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K WOLF SERVOMOTORS L50 02 A1S AUTOMATIC RELAY For servomotor, variable speed with built-in position indicator (0 to 100%) (3.15A, 230V) LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TL- HD, TLHD-K L50 POSITION INDICATOR For installation on the control panel front for variable speed servomotor activation in conjunction with automatic relay A1 For surface mounting for variable speed servomotor activation in conjunction with automatic relay A1 LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L50 24V VARIABLE SPEED SERVOMOTOR FOR MIXED AIR DAMPER In conjunction with LM2 ventilation module LH-EC, LH, TLH-EC, TLH L50 24V SERVOMOTOR FOR OPENING/CLOSING THE OUTDOOR AIR DAMPER LH-EC, LH, TLH-EC, TLH L50 230V / 50HZ SERVOMOTOR FOR OPENING / CLO- SING THE DAMPER LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ACTUATOR, 230V / 50HZ, STEPLESS FOR MIXED AIR DAMPER LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 BUTTON FOR SERVOMOTOR (230V / 50HZ) For induction louvre LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK L WOLF TLH-EC / TLH ACCESSORIES

46 02 WOLF THERMOSTATS / TERMINAL BOX ROOM THERMOSTAT for product Art. no. DG LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT WITH SUMMER/WINTER SWITCH LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT CLOCK WITH 7-DAY PRO- GRAM LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 REMOTE SENSOR FOR ROOM THERMOSTAT CLOCK LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT, INDUSTRIAL VERSION LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 FROST STAT, FITTED LH-EC/LH 25, 40, 63; TLH-EC/TLH 25, 40, 63; TLHK-EC/TLHK 25, 40, 63 LH-EC/LH 100, TLH-EC/TLH 100, TLHK-EC/TLHK L L50 UNIVERSAL TIMER WITH 7-DAY PROGRAM LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L50 EARTH STRAP FOR EQUIPOTENTIAL BONDING LH-EC, LH, LH-ATEX, TLH-EC, TLH, TLHK-EC, TLHK L50 INTERMEDIATE TERMINAL BOX FOR PARALLEL OPERATION UP TO 3 UNITS LH, LH-ATEX, TLH, LHD L50 Note: In combination with LH-ATEX, mounting only outside the explosion risk area WOLF TLH-EC / TLH ACCESSORIES

47 BASIC UNIT 02 a b c STANDARD UNIT DIMENSIONS Type Unit size a mm b mm c mm a øe d c b STANDARD UNIT CONNECTIONS Type Unit size /-3/-4-2/-3/-4-2/-3/-4-2/-3/-4 a mm b mm c mm d mm Øe mm ¾ 1 ¾ 1 1 1¼ 1 1½ WOLF TECHNICAL DATA

48 x x f x x WOLF ACCESSORIES 02 a d c e b g h i Ø10 Ø21 FIXING BRACKETS Type Unit size a mm b mm c mm 380 2x d mm e mm f mm 170 2x170 3x170 3x170 g mm h mm i mm b t FIXING KIT FOR STEEL BEAM, VERTICAL b mm t mm WOLF TECHNICAL DATA

49 ACCESSORIES a Horizontal air flow b Vertical air flow 02 c TLH TLH b c TLH TLH 100 SUSPENSION TAB FOR APPLIANCE MOUNTING Type Unit size horizontal a mm b mm c mm vertical a mm b mm c mm d min mm a a b c MOUNTING BRACKET FOR INTAKE ACCESSORIES, LOOSE Type Unit size a mm b mm c mm WOLF TECHNICAL DATA

50 ACCESSORIES 02 c d a b DISCHARGE CONE Type Unit size a mm b mm c mm d mm d e a a c b DISCHARGE NOZZLE Type Unit size a mm b mm c mm d mm e mm b c a FOUR-WAY DISCHARGE Type Unit size a mm b mm c mm a c b d e INDUCTION LOUVRE FOR WALL MOUNTED UNIT Type Unit size a mm b mm c mm d mm WOLF TECHNICAL DATA

51 a 02 c d b INDUCTION LOUVRE FOR CEILING UNIT Type Unit size a mm b mm c mm d mm d a a WOLF ACCESSORIES b c e MIXING BOX/THERMALLY INSULATED MIXING BOX Type Unit size a mm b mm c mm d mm e mm b c RECIRCULATION AIR BOX WITH LATERAL INTAKE Type Unit size a mm b mm c mm a b c FILTER BOX Type Unit size a mm b mm c mm WOLF TECHNICAL DATA

52 ACCESSORIES a FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Type Unit size a mm WOLF TECHNICAL DATA

53 TLHK-EC / TLHK TOPWING UNIT HEATER 03 TOPWING 2 TOPWING TLHK-EC TOPWING TLHK TopWing air heater for heating or cooling with EC fan TopWing air heater for heating or cooling WRS CONTROL SYSTEMS / CONTROL ACCESSORIES 4 WRS CONTROL SYSTEMS 4 CONTROL ACCESSORIES 5 ACCESSORIES 7 CONNECTING ACCESSORIES 7 DEVICE FASTENINGS 9 INTAKE ACCESSORIES 10 TECHNICAL DATA 11 BASIC UNIT 11 ACCESSORIES WOLF

54 03 TOPWING TLHK-EC TOPWING AIR HEATER FOR HEATING OR COOLING WITH EC FAN RG L50 Air heater for heating or cooling in recirculation air mode or mixed air mode for wall mounting. Casing: traffic white RAL 9016 Induction louvre with secondary air cone Free condensate drain Full motor protection with integral temperature monitoring Energy saving EC fans (1 x 230V) EC-motor 230V / 50Hz Heat exchanger: copper-aluminium LPHW / ch.w. Induction louver with servomotor 24V can be controlled via LM2 ventilation control unit Induction louvre with servomotor 230V / 50Hz For control via pushbutton Manually adjustable induction louvre Art. no Art. no Art. no RAL and special colours by request WOLF TOPWING

55 TOPWING TLHK TOPWING AIR HEATER FOR HEATING OR COOLING 03 RG L50 Air heater for heating or cooling in recirculation air mode or mixed air mode for wall mounting. Casing: traffic white RAL 9016 Induction louvre with secondary air cone Free condensate drain Full motor protection with built-in thermal contacts Single phase AC motor 230V / 50Hz Heat exchanger: copper-aluminium LPHW / ch.w. Induction louver with servomotor 24V can be controlled via LM2 ventilation control unit Induction louvre with servomotor 230V / 50Hz For control via pushbutton Manually adjustable induction louvre Art. no Art. no Art. no Three-phase motor 3 x 400V / 50Hz Heat exchanger: copper-aluminium LPHW / ch.w. Induction louver with servomotor 24V can be controlled via LM2 ventilation control unit Induction louvre with servomotor 230V / 50Hz For control via pushbutton Manually adjustable induction louvre Art. no Art. no Art. no RAL and special colours by request WOLF TOPWING

56 WRS CONTROL SYSTEMS Art. no. DG 03 BML VENTILATION PROGRAMMING UNIT Room temperature-compensated temperature control Graphic display with backlight Simple menu navigation through plain text display Operation using rotary knob with push-function 4 function keys for frequently used functions (information, temperature, speed setting, fresh air proportion) Mounted optionally in the ventilation module or in the wall holder as remote control Only one ventilation operating module BML is needed to operate up to 7 zones Demand-optimised boiler water temperature demand via ebus ebus interface L50 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 LM1 VENTILATION MODULE (incl. room temperature sensor) Ventilation module for controlling unit heaters with two-stage motor Simple configuration of the controller by selecting predefined system diagrams Demand-optimised room temperature control via the rotary speed of the unit heater Operation of the heating circuit pump Operation of the heat generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Note: Not in conjunction with EC motor L50 LM2 VENTILATION MODULE Ventilation module LM2 for controlling the room temperature by means of the rotation speed or the mixer control 2-stage motor control in connection with ventilation module LM1 or variable speed control via EC-motor Simple configuration of the controller by selecting predefined system diagrams Operation of the heat or cooling generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Mixed air flap control Induction louvre control L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

57 CONTROL ACCESSORIES Art. no. DG OUTSIDE, CEILING OR ROOM TEMPERATURE SEN- SOR LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, LHD, TL- HD-EC, TLHD-K-EC, TLHD, TLHD-K, CFL-WRG, CFL- EC-ZUL, CKL, CRL H41 03 BUTTON FOR SERVOMOTOR (230V / 50HZ) For induction louvre LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK L50 FROST STAT, FITTED LH-EC/LH 25, 40, 63; TLH-EC/TLH 25, 40, 63; TLHK-EC/TLHK 25, 40, 63 LH-EC/LH 100, TLH-EC/TLH 100, TLHK-EC/TLHK L L50 DIFFERENTIAL PRESSURE SWITCH For filter monitoring Loose Fitted LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, TLHD-EC, TLHD-K-EC, TLHD, TLHD- K LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, TLHD-EC, TLHD-K-EC, TLHD, TLHD- K L L50 EARTH STRAP FOR EQUIPOTENTIAL BONDING LH-EC, LH, LH-ATEX, TLH-EC, TLH, TLHK-EC, TLHK L50 5-STAGE SWITCH Electronic 5-stage speed controller, input 0-10V (2A, 400V) (4A, 400V) (6A, 230V) LH, TLH, TLHK, LHD, TL- HD, TLHD-K LH, TLH, TLHK, LHD, TL- HD, TLHD-K LH, TLH, TLHK, LHD, TL- HD, TLHD-K L L L50 Note: Not in conjunction with EC motor. TEMPERATURE SENSOR (NTC 5K, Ø 6MM) LOOSE can be used as a cylinder, boiler, central unit and supply air temperature sensor H41 SENSOR HOLDER For supply air sensor Supply air sensor (NTC 5K) L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

58 CONTROL ACCESSORIES Art. no. DG 03 ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, LHD, TL- HD-EC, TLHD-K-EC, TLHD, TLHD-K, CGL, CFL-EC-ZUL L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

59 CONNECTING ACCESSORIES for product Art. no. DG SHUT-OFF SETS FOR HEAT EXCHANGER FOR FLOW AND RETURN Consisting of: 1 threaded connection for connecting to flow and return with flat gasket, automatic air vent valve, drain and fill valve, ball valves with 1 female thread in flow and return, ¾ male thread connection option (e.g. for the thermometer) in flow and return, suitable for heating water temperatures up to max. 110 C and operating pressure up to max. 10bar. 03 Straight-through version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100, LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40; TLHD-EC, TLHD-K-EC, TLHD, TLHD-K Right angle version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100 LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L WOLF ACCESSORIES

60 CONNECTING ACCESSORIES for product Art. no. DG 03 FLANGE SET Consisting of 2 threaded flanges, 2 welded flanges and 2 flat gaskets, plus hexagonal bolts and hexagonal nuts DN25, R 1 DN32, R 1¼ DN40, R 1½ LH-EC/LH 25,40 Type 2/3/4; LH 25/40-ATEX Type 2/3/4; LH-EC/LH 63,100 Type 1; LH 63/100-ATEX Type 1; TLH-EC/TLH 25,40 Type 2/3/4; TLH-EC/TLH 63,100 Type 1; TLHK 25, 40; LHD LH-EC/LH 63, Type 2/3/4; LH 63-ATEX Type 2/3/4; TLH-EC/TLH 63 Type 2/3/4; TLHK 63 LH-EC/LH 63, Type 2/3/4; LH 63-ATEX Type 2/3/4; TLH-EC/TLH 63 Type 2/3/4; TLHK L L L50 HYDRONIC BALANCING VALVE DN20, 4-15 l/min L50 DN20, 8-30 l/min L50 DN25, 6-20 l/min L50 DN25, l/min L50 DN32, l/min L50 DN40, l/min L50 CONDENSATE PUMP WITH POTENTIAL-FREE, FUL- LY WIRED ALARM OUTPUT Consisting of: Condensate pump with floating alarm output, condensate tank with lid and wall retainer, PVC hose 10mm (6m long), non-return valve, condensate inlet adaptor TLHK-EC, TLHK, CWL Excellent, CWL-F/T-Excellent, COB, TOB H40 DRAIN OUTLET R1 With trap and pipe collar Transparent plastic TLHK-EC, TLHK, TLHD-EC, TLHD-K-EC, TLHD,TLHD-K L WOLF ACCESSORIES

61 DEVICE FASTENINGS for product Art. no. DG FIXING BRACKETS For installation on the wall or ceiling, made from 2mm folded sheet steel, powder-coated, colour: traffic white RAL Consisting of: - 2 brackets - Hexagon bolts for installing on appliance 03 unit size 25, L50 unit size 63, L50 FIXING KIT FOR CONCRETE LINTEL, VERTICAL For fixing to a concrete beam by suspending from pre-mounted fixing rails. Consisting of: Mounting rail, 2 support rails, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 FIXING KIT FOR STEEL BEAM, VERTICAL For fixing to a steel beam by suspending from pre-mounted fixing rails with clamping claws. Suitable for all steel beams with a flange width of 100mm to 300mm and a flange thickness of 6mm to 21mm. Consisting of: Mounting rail, 2 support rails, 4 clamping claws, nuts and bolts (only in conjunction with fixing brackets) Zinc-plated sheet steel unit size L50 unit size L50 SUSPENSION TAB FOR APPLIANCE MOUNTING Powder-coated, colour: traffic white RAL 9016 Suitable for installation with threaded rods or perforated strip for configurations with horizontal air routing. 1 Set = 4 items L50 MOUNTING BRACKET FOR INTAKE ACCESSO- RIES, LOOSE For installing the appliance on the wall or ceiling with fitted mixed air box, recirculation air box, outdoor air box or filter box. Powder-coated, colour: traffic white RAL mounting brackets are required for fastening. These are included with the corresponding intake accessories. (Sealing against the wall/ceiling on site). 1 pce L50 4-pce set L WOLF ACCESSORIES

62 INTAKE ACCESSORIES for product Art. no. DG 03 MIXING BOX/THERMALLY INSULATED MIXING BOX Mixed air box in thermally insulated version to prevent the formation of condensate. For individual adjustment of the outdoor air flow rate. Outdoor air intake at the back, recirculation air intake at the side or, when mixed air box is rotated by 90, from above/below. Variable manual adjustment between pure recirculation air mode via mixed air to pure outdoor air mode. Powder-coated, colour: traffic white RAL Mounting bracket as standard. Without thermal insulation unit size 25 on request unit size 40 on request unit size 63 on request unit size 100 on request With thermal insulation unit size 25 on request unit size 40 on request unit size 63 on request unit size 100 on request Note: If used in outdoor air mode, air heaters are covered by the scope of application of EU Regulation 1253/2014. RECIRCULATION AIR BOX WITH LATERAL INTAKE For recirculation air intake through two grilles at the side or, when rotated by 90, intake from top and bottom. Powder-coated, colour: traffic white RAL Mounting bracket as standard. unit size L50 unit size L50 unit size L50 unit size L50 FILTER BOX With filter element as dust trap in outdoor air and mixed air modes, filter category G4 for model size 63 and G3 for model size 25/40/100. Mounting bracket on request. Powder-coated, colour: traffic white RAL unit size L50 unit size L50 unit size L50 unit size L50 FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Note: In combination with LH-ATEX, an earth strap is required for equipotential bonding (part no ). unit size L50 unit size L50 unit size L50 unit size L WOLF ACCESSORIES

63 BASIC UNIT a 03 b d c STANDARD UNIT DIMENSIONS Type Unit size a mm b mm c mm d mm a øe c d 53 1/2 b STANDARD UNIT CONNECTIONS Type Unit size a mm b mm c mm d mm Øe mm 1 1 1¼ 1½ WOLF TECHNICAL DATA

64 x x f x x WOLF ACCESSORIES 03 a d c e b g h i Ø10 Ø21 FIXING BRACKETS Type Unit size a mm b mm c mm 380 2x d mm e mm f mm 170 2x170 3x170 3x170 g mm h mm i mm b t FIXING KIT FOR STEEL BEAM, VERTICAL b mm t mm WOLF TECHNICAL DATA

65 ACCESSORIES Horizontal air flow Vertical air flow a b c 03 TLH TLH b c TLH TLH 100 SUSPENSION TAB FOR APPLIANCE MOUNTING Type Unit size horizontal a mm b mm c mm vertical a mm b mm c mm d min mm a a b c MOUNTING BRACKET FOR INTAKE ACCESSORIES, LOOSE Type Unit size a mm b mm c mm d a b c e MIXING BOX/THERMALLY INSULATED MIXING BOX Type Unit size a mm b mm c mm d mm e mm WOLF TECHNICAL DATA

66 a WOLF ACCESSORIES 03 b c RECIRCULATION AIR BOX WITH LATERAL INTAKE Type Unit size a mm b mm c mm a b c FILTER BOX Type Unit size a mm b mm c mm a FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Type Unit size a mm WOLF TECHNICAL DATA

67 LHD UNIT HEATER 04 LHD 2 LHD Air heater for mounting directly to the ceiling 2 WRS CONTROL SYSTEMS / CONTROL ACCESSORIES 3 WRS CONTROL SYSTEMS 3 CONTROL ACCESSORIES 4 ACCESSORIES 5 SWITCHING DEVICES 5 THERMOSTATS / TERMINAL BOX 6 CONNECTING ACCESSORIES 7 TECHNICAL DATA 8 BASIC UNIT WOLF

68 LHD AIR HEATER FOR MOUNTING DIRECTLY TO THE CEI- LING 04 RG L50 Air heater for direct mounting on the ceiling in recirculation air mode. Full motor protection with built-in thermal contacts Air intake vertical, air discharge horizontal. Colour: traffic white RAL 9016 Three-phase motor 3 x 400V / 50Hz Heat exchanger: copper-aluminium LPHW Art. no , , WOLF LHD

69 WRS CONTROL SYSTEMS Art. no. DG BML VENTILATION PROGRAMMING UNIT Room temperature-compensated temperature control Graphic display with backlight Simple menu navigation through plain text display Operation using rotary knob with push-function 4 function keys for frequently used functions (information, temperature, speed setting, fresh air proportion) Mounted optionally in the ventilation module or in the wall holder as remote control Only one ventilation operating module BML is needed to operate up to 7 zones Demand-optimised boiler water temperature demand via ebus ebus interface L50 04 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 LM1 VENTILATION MODULE (incl. room temperature sensor) Ventilation module for controlling unit heaters with two-stage motor Simple configuration of the controller by selecting predefined system diagrams Demand-optimised room temperature control via the rotary speed of the unit heater Operation of the heating circuit pump Operation of the heat generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Note: Not in conjunction with EC motor L50 LM2 VENTILATION MODULE Ventilation module LM2 for controlling the room temperature by means of the rotation speed or the mixer control 2-stage motor control in connection with ventilation module LM1 or variable speed control via EC-motor Simple configuration of the controller by selecting predefined system diagrams Operation of the heat or cooling generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Mixed air flap control Induction louvre control L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

70 CONTROL ACCESSORIES Art. no. DG OUTSIDE, CEILING OR ROOM TEMPERATURE SENSOR H STAGE SWITCH Electronic 5-stage speed controller, input 0-10V (2A, 400V) L50 (4A, 400V) L50 Note: Not in conjunction with EC motor. TEMPERATURE SENSOR (NTC 5K, Ø 6MM) LOOSE can be used as a cylinder, boiler, central unit and supply air temperature sensor H41 SENSOR HOLDER For supply air sensor L50 ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

71 SWITCHING DEVICES Art. no. DG 1-STAGE SWITCH D1-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart L50 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. 2-STAGE SWITCH DS-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation L STAGE SWITCH D 3-4 Full motor protection switch (4A, 400V) with lock preventing unintentional restart Note: In combination with LH-ATEX, installation only outside the potentially explosive area L50 5-STAGE SWITCH D5... Full motor protection switch with lock preventing unintentional restart D5-1 (1A, 400V) L50 D5-3 (2A, 400V) L50 D5-7 (4A, 400V) L50 D5-12 (7A, 400V) L50 Note: In combination with LH-ATEX, installation only outside the potentially explosive area WOLF ACCESSORIES

72 THERMOSTATS / TERMINAL BOX Art. no. DG INTERMEDIATE TERMINAL BOX FOR PARALLEL OPERATION UP TO 3 UNITS L50 Note: In combination with LH-ATEX, mounting only outside the explosion risk area. 04 ROOM THERMOSTAT L50 ROOM THERMOSTAT CLOCK WITH 7-DAY PROGRAM L50 REMOTE SENSOR FOR ROOM THERMOSTAT CLOCK L50 ROOM THERMOSTAT, INDUSTRIAL VERSION L WOLF ACCESSORIES

73 CONNECTING ACCESSORIES Art. no. DG HYDRONIC BALANCING VALVE DN20, 4-15 l/min L50 DN20, 8-30 l/min L50 DN25, 6-20 l/min L50 DN25, l/min L50 DN32, l/min L50 DN40, l/min L50 FLANGE SET Consisting of 2 threaded flanges, 2 welded flanges and 2 flat gaskets, plus hexagonal bolts and hexagonal nuts DN25, R L WOLF ACCESSORIES

74 BASIC UNIT b a c Ød Ød 04 a 70 STANDARD UNIT DIMENSIONS Type LHD a mm b mm c mm Ød mm WOLF TECHNICAL DATA

75 TLHD-EC / TLHD-K-EC / TLHD / TLHD-K TOP- WING UNIT HEATER 05 TOPWING 2 TOPWING TLHD-EC TOPWING TLHD-K-EC TOPWING TLHD TOPWING TLHD-K TopWing air heater for heating with EC fan TopWing air heater for heating or cooling with EC fan TopWing air heater for heating TopWing air heater for heating or cooling WRS CONTROL SYSTEMS / CONTROL ACCESSORIES 6 WRS CONTROL SYSTEMS 6 CONTROL ACCESSORIES 7 ACCESSORIES 8 CONNECTING ACCESSORIES 8 ACCESSORIES 9 SWITCHING DEVICES 12 SERVOMOTORS 13 THERMOSTATES 14 TECHNICAL DATA 15 BASIC UNIT 15 ACCESSORIES WOLF

76 TOPWING TLHD-EC TOPWING AIR HEATER FOR HEATING WITH EC FAN 05 Air heater for heating; mounting on the ceiling for recirculation air mode or on an intermediate ceiling for recirculation air or mixed air mode. Colour: traffic white RAL 9016 Energy saving EC fans (1 x 230V) RG L50 Standard units for mixed air mode with additional thermal insulation to prevent the formation of condensate on the unit Full motor protection with integral temperature monitoring Mixed air operation* Heat exchanger: copper-aluminium LPHW Heating (230V) Return air operation Heat exchanger: copper-aluminium LPHW Heating (230V) Art. no Art. no * Mixing temperature before the heat exchanger min. +5 C WOLF TOPWING

77 TOPWING TLHD-K-EC TOPWING AIR HEATER FOR HEATING OR COOLING WITH EC FAN Air heater for heating or cooling; mounting on the ceiling for recirculation air mode or on an intermediate ceiling for recirculation air or mixed air mode. Colour: traffic white RAL 9016 Full motor protection with integral temperature monitoring RG L50 Standard units for mixed air mode with integral condensate pump and additional thermal insulation to prevent the formation of condensate on the unit Standard units for recirculation air mode with integral condensate pump 05 Energy saving EC fans (1 x 230V) Mixed air operation* Heat exchanger: copper-aluminium LPHW / ch.w Heating / Cooling (230V) Art. no Return air operation Heat exchanger: copper-aluminium LPHW / ch.w. Heating / Cooling (230V) Art. no * Mixing temperature before the heat exchanger min. +5 C WOLF TOPWING

78 TOPWING TLHD TOPWING AIR HEATER FOR HEATING 05 Air heater for heating; mounting on the ceiling for recirculation air mode or on an intermediate ceiling for recirculation air or mixed air mode. RG L50 Standard units for mixed air mode with additional thermal insulation to prevent the formation of condensate on the unit Colour: traffic white RAL 9016 Full motor protection with built-in thermal contacts Mixed air operation* Heat exchanger: copper-aluminium LPHW Heating (400V) Return air operation Heat exchanger: copper-aluminium LPHW Heating (400V) Art. no Art. no * Mixing temperature before the heat exchanger min. +5 C WOLF TOPWING

79 TOPWING TLHD-K TOPWING AIR HEATER FOR HEATING OR COOLING Air heater for heating or cooling; mounting on the ceiling for recirculation air mode or on an intermediate ceiling for recirculation air or mixed air mode. Colour: traffic white RAL 9016 Full motor protection with built-in thermal contacts RG L50 Standard units for mixed air mode with integral condensate pump and additional thermal insulation to prevent the formation of condensate on the unit Standard units for recirculation air mode with integral condensate pump 05 Mixed air operation* Heat exchanger: copper-aluminium LPHW / ch.w Heating / Cooling (400V) Art. no Return air operation Heat exchanger: copper-aluminium LPHW / ch.w. Heating / Cooling (400V) Art. no * Mixing temperature before the heat exchanger min. +5 C WOLF TOPWING

80 WRS CONTROL SYSTEMS Art. no. DG BML VENTILATION PROGRAMMING UNIT Room temperature-compensated temperature control Graphic display with backlight Simple menu navigation through plain text display Operation using rotary knob with push-function 4 function keys for frequently used functions (information, temperature, speed setting, fresh air proportion) Mounted optionally in the ventilation module or in the wall holder as remote control Only one ventilation operating module BML is needed to operate up to 7 zones Demand-optimised boiler water temperature demand via ebus ebus interface L50 05 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 LM1 VENTILATION MODULE (incl. room temperature sensor) Ventilation module for controlling unit heaters with two-stage motor Simple configuration of the controller by selecting predefined system diagrams Demand-optimised room temperature control via the rotary speed of the unit heater Operation of the heating circuit pump Operation of the heat generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Note: Not in conjunction with EC motor L50 LM2 VENTILATION MODULE Ventilation module LM2 for controlling the room temperature by means of the rotation speed or the mixer control 2-stage motor control in connection with ventilation module LM1 or variable speed control via EC-motor Simple configuration of the controller by selecting predefined system diagrams Operation of the heat or cooling generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Mixed air flap control Induction louvre control L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

81 CONTROL ACCESSORIES Art. no. DG OUTSIDE, CEILING OR ROOM TEMPERATURE SENSOR H41 DIFFERENTIAL PRESSURE SWITCH For filter monitoring Loose L50 Fitted L50 5-STAGE SWITCH Electronic 5-stage speed controller, input 0-10V (2A, 400V) L50 (4A, 400V) L50 05 Note: Not in conjunction with EC motor. TEMPERATURE SENSOR (NTC 5K, Ø 6MM) LOOSE can be used as a cylinder, boiler, central unit and supply air temperature sensor H41 SENSOR HOLDER For supply air sensor L50 ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables L WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

82 CONNECTING ACCESSORIES for product Art. no. DG 05 SHUT-OFF SETS FOR HEAT EXCHANGER FOR FLOW AND RETURN Consisting of: 1 threaded connection for connecting to flow and return with flat gasket, automatic air vent valve, drain and fill valve, ball valves with 1 female thread in flow and return, ¾ male thread connection option (e.g. for the thermometer) in flow and return, suitable for heating water temperatures up to max. 110 C and operating pressure up to max. 10bar. Straight-through version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100, LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40; TLHD-EC, TLHD-K-EC, TLHD, TLHD-K Right angle version LH-EC/LH 25, LH25-ATEX Type 2/3/4; LH-EC/LH 40, LH40-ATEX Type 2/3/4; LH-EC/LH 63, LH63-ATEX Type 1; LH-EC/LH 100 LH100-ATEX Type 1; TLH-EC 25 Type 2/3/4; TLH 25 Type 2/3/4; TLH-EC 40 Type 2/3/4; TLH 40 Type 2/3/4; TLH-EC/TLH 63 Type 1; TLH-EC/TLH 100 Type 1; TLHK-EC/TLHK 25, 40, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L50 HYDRONIC BALANCING VALVE DN20, 4-15 l/min L50 DN20, 8-30 l/min L50 DN25, 6-20 l/min L50 DN25, l/min L50 DN32, l/min L50 DN40, l/min L50 DRAIN OUTLET R1 With trap and pipe collar Transparent plastic TLHK-EC, TLHK, TLHD-EC, TLHD-K-EC, TLHD,TLHD-K L WOLF ACCESSORIES

83 ACCESSORIES for product Art. no. DG TOP FILTER For TLHD-EC, TLHD-K-EC, TLHD, TLHD-K, category G4 (Not suitable for duct connection) unit size L50 unit size L50 SUCTION RING For lining the intake air gap when installing directly on the ceiling or as a decorative cover in all installation examples Traffic white RAL 9016 Height 100mm unit size L50 unit size L50 05 EMPTY SECTION 25mm twin wall casing, thermally insulated Zinc-plated sheet steel unit size L50 unit size L50 ADAPTOR PLATE For connecting a round slider with empty section or attachment frame, thermally insulated Zinc-plated sheet steel unit size L50 unit size L50 SLIDER To compensate for dimensional differences Min. height = 300mm, max. height = 500mm Zinc-plated sheet steel unit size L50 unit size L50 FLEXIBLE CONNECTION For connection to TLHD Height 130mm unit size L50 unit size L50 FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME For connection to duct unit size L50 unit size L50 FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME unit size L50 unit size L50 Note: In combination with LH-ATEX, an earth strap is required for equipotential bonding (part no ) WOLF ACCESSORIES

84 ACCESSORIES for product Art. no. DG FILTER ATTACHMENT BOX With filter category G4 Zinc-plated sheet steel Depth 100mm unit size L50 unit size L50 THERMALLY INSULATED ATTACHMENT FRAME For installation in grid ceiling 620 x 620 for connecting a louvre damper or adaptor plate to the recirculation air intake grille Zinc-plated sheet steel Height and width 590mm, depth 100mm L50 05 RECIRCULATION AIR INTAKE PLATE Colour: traffic white RAL 9016 For installation in the attachment frame, suitable for Euro grid ceiling Height and width 620mm, depth 100mm L50 LOUVRE DAMPER For duct Zinc-plated sheet steel unit size L50 unit size L50 TD CEILING DISCHARGE Casing such as TLHD(-EC), without heat exchangers, without fan motor unit, as ceiling discharge. Traffic white RAL 9016 unit size L50 unit size L50 MOUNTING BRACKET For installing the appliance on the wall or ceiling with fitted mixed air box, recirculation air box, outdoor air box or filter box. Zinc-plated sheet steel 4 mounting brackets are required for fastening. These are included with the corresponding intake accessories. (Sealing against the wall/ceiling on site). 1 pce L50 2-pce set L50 4-pce set L50 UNIVERSAL CASING PANEL, FRONT As adaptor from empty section/fan section to on-site duct. The apertures have to be made individually on site. Zinc-plated sheet steel unit size L50 unit size L WOLF ACCESSORIES

85 ACCESSORIES for product Art. no. DG UNIVERSAL CASING PANEL, SQUARE As adaptor from empty section TLHD(-ED) 63 to accessory louvre damper/slider TLHD(-EC) 40. The apertures have to be made individually on site. Zinc-plated sheet steel Width and depth 760mm unit size L WOLF ACCESSORIES

86 SWITCHING DEVICES for product Art. no. DG VARIABLE SPEED CONTROLLER For variable operation of one or more unit heaters with EC motor (0-10V) LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L50 1-STAGE SWITCH D1-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 05 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. 2-STAGE SWITCH DS-2 Full motor protection switch (8A, 400V) with lock preventing unintentional restart LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. Full motor protection provided by thermistor in connection with thermistor triggering unit for control panel installation. 3-STAGE SWITCH D 3-4 Full motor protection switch (4A, 400V) with lock preventing unintentional restart LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K L50 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. 5-STAGE SWITCH D5... Full motor protection switch with lock preventing unintentional restart D5-1 (1A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-3 (2A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-7 (4A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-12 (7A, 400V) LH, LH-ATEX, TLH, LHD, TLHD, TLHD-K D5-19 (12A, 400V) LH, LH-ATEX, TLH, TLHD, TLHD-K L L L L L54 Note: In combination with LH-ATEX, installation only outside the potentially explosive area. UNIVERSAL TIMER WITH 7-DAY PROGRAM LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L50 OMNIPOLAR REPAIR SWITCH AR8, 1N/C+1N/O TLHD-EC, TLHD-K-EC, TL- HD, TLHD-K L WOLF ACCESSORIES

87 SERVOMOTORS for product Art. no. DG A1 AUTOMATIC RELAY For servomotor open/close (3.15A, 230V) LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 A1S AUTOMATIC RELAY For servomotor, variable speed with built-in position indicator (0 to 100%) (3.15A, 230V) LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TL- HD, TLHD-K L50 ACTUATOR, 230V / 50 HZ, STEPLESS FOR MI- XING AIR DAMPER LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L V / 50 HZ SERVOMOTOR FOR OPENING / CLOSING THE DAMPER LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 POSITION INDICATOR For installation on the control panel front for variable speed servomotor activation in conjunction with automatic relay A1 For surface mounting for variable speed servomotor activation in conjunction with automatic relay A1 LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L L WOLF ACCESSORIES

88 THERMOSTATES for product Art. no. DG CONTACT FROST STAT Setting range 0 C to 60 C (to be mounted on the return) TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 FROST STAT SP-1 Incl. sensor well (to be mounted in the return) TLHD-EC, TLHD-K-EC, TLHD, TLHD-K H41 FROST STAT, FITTED 05 TLHD-EC/TLHD L50 TLHD-K-EC/TLHD-K L50 TLHD-EC/TLHD L50 TLHD-K-EC/TLHD-K L50 ROOM THERMOSTAT LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT WITH SUMMER/WINTER SWITCH LH-EC, LH, TLH-EC, TLH, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT CLOCK WITH 7-DAY PRO- GRAM LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 REMOTE SENSOR FOR ROOM THERMOSTAT CLOCK LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L50 ROOM THERMOSTAT, INDUSTRIAL VERSION LH-EC, LH, TLH-EC, TLH, LHD, TLHD-EC, TLHD-K-EC, TLHD, TLHD-K L WOLF ACCESSORIES

89 BASIC UNIT 34 a e a f c d 85 3x120 b Øg STANDARD UNIT DIMENSIONS Type Unit size a mm b mm c mm d mm e mm f mm R 317 R 382 Øg mm WOLF TECHNICAL DATA

90 ACCESSORIES b Ø TOP FILTER Type Unit size Ø mm b mm a b 05 EMPTY SECTION Type Unit size a mm b mm a Ø ADAPTOR PLATE Type Unit size Ø mm a mm Ø l SLIDER Type Unit size Ø mm I mm Ø 130 FLEXIBLE CONNECTION Type Unit size Ø mm WOLF TECHNICAL DATA

91 ACCESSORIES 30 a b FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Type Unit size a mm b mm a FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Type Unit size a mm a b 100 FILTER ATTACHMENT BOX Type Unit size a mm b mm a b LOUVRE DAMPER Type Unit size a mm b mm a b c MOUNTING BRACKET Type Unit size a mm b mm c mm WOLF TECHNICAL DATA

92 ACCESSORIES a b UNIVERSAL CASING PANEL, FRONT Type Unit size a mm b mm WOLF TECHNICAL DATA

93 TL-2 WARM AIR CURTAIN UNIT WARM AIR CURTAIN UNIT 2 TL-2 Warm air curtain 2 CONTROL SYSTEMS / CONTROL ACCESSORIES 3 CONTROL SYSTEMS 3 CONTROL ACCESSORIES 4 06 ACCESSORIES 5 TECHNICAL DATA 6 BASIC UNIT WOLF

94 TL-2 WARM AIR CURTAIN RG L52 Warm air curtain device with intake filter Filter: renewable, category G2 Casing: traffic white RAL 9016 Standard units without controller* 06 PWW heat exchanger, copper/aluminium Fans 230V / 50Hz TL-2 A10 TL-2 A20 TL-2 A30 TL-2 A40 Art. no Art. no Art. no Art. no. on request on request on request on request on request on request on request on request on request on request * It is compulsory to use a control of type WTC3 or WTC5 for the operation of the warm air curtain devices WOLF WARM AIR CURTAIN UNIT

95 CONTROL SYSTEMS CONTROL SYSTEM WTMC 300 Hardwired programming unit (remote control), control PBC (master) and optional PCB (slave) for 3-stage or variable control of warm air curtain units Graphical display and adaption via touch panel 2-language, easy and self explaining menu guiding Extendable up to 9 units and controllable in parallel Hand/automatic function: room thermostat and/or door contact Summer/winter function: control of magnetic valve or pump Key blocking Display of malfunctions via memory for remote diagnosis for product Art. no. DG TL-2 A L52 CONTROL SYSTEM WTMC 500 Hardwired programming unit (remote control), control PBC (master) and optional PCB (slave) for 5-stage or variable control of warm air curtain units Graphical display and adaption via touch panel 2-language, easy and self explaining menu guiding Extendable up to 9 units and controllable in parallel Hand/automatic function: room thermostat and/or door contact with adjustable run-ontime Summer/winter function: control of magnetic valve or pump Key blocking Display of malfunctions via memory for remote diagnosis Integrated, electronic filter monitoring Potential-free release, operating and malfunction message to BMS TL-2 A L52 06 CONTROL SYSTEM TYPE WTMC 300 E For warm air curtain units with electric heating coil TL-2 A10-30 on request WOLF CONTROL SYSTEMS / CONTROL ACCESSORIES

96 CONTROL ACCESSORIES for product Art. no. DG FROST STAT WTF TL-2 A L52 WTR 2 THERMOSTATIC CONTROL VALVE, LOOSE Straight-through valve DN20/Kvs 5.0 TL-2 A L52 Right angle valve DN20/Kvs 7.0 TL-2 A L52 WTR 3 THERMOSTATIC MIXING VALVE, LOOSE Right angle valve DN20/Kvs 4.5 TL-2 A L52 Right angle valve DN25/Kvs 6.5 TL-2 A10-40 on request Right angle valve DN32/Kvs 9.5 TL-2 A10-40 on request WTAV THERMOSTATIC SHUT-OFF VALVE, LOOSE In conjunction with speed/air flow rate controller Straight-through valve DN20/Kvs 1.1 TL-2 A L52 Right angle valve DN20/Kvs 1.1 TL-2 A L WOLF CONTROL SYSTEMS / CONTROL ACCESSORIES

97 ACCESSORIES for product Art. no. STEAM HEAT EXCHANGER TL-2 on request ELECTRIC HEAT EXCHANGER TL-2 on request WDH 4 CEILING MOUNTING KIT TL-2 A10/1000, TL-2 A10/1500, TL-2 A10/2000, TL-2 A20/1000, TL-2 A20/1500, TL-2 A20/2000, TL-2 A30/1000, TL-2 A30/1500, TL-2 A30/2000, TL-2 A40/1000, TL-2 A40/1500, TL-2 A40/ L52 WDH 6 CEILING MOUNTING KIT TL-2 A10/2500, TL-2 A10/3000, TL-2 A20/2500, TL-2 A20/3000, TL-2 A30/2500, TL-2 A30/3000, TL-2 A40/2500, TL-2 A40/ L WOLF TL-2 WARM AIR CURTAIN UNIT

98 BASIC UNIT a b c DIMENSIONS TL-2 A10-30/ a mm b mm c mm TL-2 A40/ a mm b mm c mm WOLF TECHNICAL DATA

99 LD 15 CEILING FAN CEILING FAN 2 LD 15 Ceiling mounted fan 2 CONTROL SYSTEMS WOLF

100 LD 15 CEILING MOUNTED FAN RG L50 Ceiling fan for high air circulation rate and low power consumption. Low noise operation. Energy saving through warm air recirculation in winter mode; cooling in summer mode; long service life and high operational reliability. 07 Ceiling-mounted fan, overall height 690mm Impeller diameter 142cm Protection class IP20 Art. no shorter or longer suspension rods overall height 440mm Protection class IP54 With protection grille Air throw up to 20m room height Art. no. on request on request Actuation also possible via ventilation module LM1 and LM WOLF CEILING FAN

101 CONTROL SYSTEMS Art. no. DG WARM AIR RETURN CONTROLLER 230V / 50Hz, max. switching current 8A (4A motor power) 1 changeover contact, relay contact L50 VARIABLE SPEED CONTROLLER 230V / 50Hz for max. five ceiling fans Max. switching current 1.5A L50 Max. switching current 3.0A L WOLF LD 15 CEILING FAN

102 NOTES WOLF LD 15 CEILING FAN

103 ER SMOKE EXTRACT FANS SMOKE EXTRACT FANS 2 ER Smoke extract fan 2 ACCESSORIES WOLF

104 ER SMOKE EXTRACT FAN RG L53 Smoke extract fan RDM 57: 600 C / 120min. RDM 56: 400 C / 120min W D D D W HD W HD W W HD W HD-19 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , , WOLF SMOKE EXTRACT FANS

105 W HD W D HD W HD W-31 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no , , WOLF SMOKE EXTRACT FANS

106 ACCESSORIES for product Art. no. DG ZBS FLAT ROOF UPSTAND 600 C External material aluminium; internal casing made from coated sheet steel RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 ZBS FLAT ROOF UPSTAND 400 C Zinc-plated sheet steel (only in combination with duct connection and RDM 56, otherwise ZBS flat roof upstand 600 C) RDM L53 RDM L53 RDM L53 RDM L53 RDM L53 RDM L53 08 ZKE INTAKE CONNECTOR (FLEXIBLE CONNEC- TION PIECE) ZKF INTAKE FLANGE / MATING FLANGE Zinc-plated sheet steel RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 ZSG CONTACT PROTECTION GRILLE RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 ZDS UPSTAND SILENCER Coated sheet steel RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L53 RDM 56/ L WOLF ER SMOKE EXTRACT FANS

107 ACCESSORIES for product Art. no. DG ESH 21 INSPECTION SWITCH RDM 56/ W L53 RDM 56/ D-10 RDM 56/ D-10 RDM 56/ D-10 RDM 56/ W-13 RDM 56/ W-16 RDM 56/ W-17 RDM 56/ W-13 RDM 56/ W-16 RDM 56/ W-21 RDM 56/ D-21 RDM 56/ HD L53 RDM 56/ HD-14 RDM 56/ HD-16 RDM 56/ HD-19 RDM 56/ HD-24 RDM 56/ HD-28 RDM 56/ W-24 RDM 56/ W L53 RDM 56/ HD-26 RDM 56/ W L53 RDM 56/ ID-34 RDM 56/ GD L53 ARM-1 AUTOMATIC SMOKE DETECTOR ER L53 AMM-2 AUTOMATIC MULTI SENSOR SMOKE DE- TECTOR ER L53 08 DKM-2K-OR MANUAL PUSHBUTTON DETECTOR ER L WOLF ER SMOKE EXTRACT FANS

108 ACCESSORIES for product Art. no. DG NEW AES - EXHAUST AIR AND SMOKE EXTRACTION CONTROLS As per VMDA for ventilating rooms and smoke extraction in the event of a fire Reduction safety through TÜV assessments, robust plastic casing For one or two-stage fan motors up to 45kW Ventilation valve controls Motor protection shutdown during smoke extraction Push button and smoke detector connection Fire services switch connection 08 RDM 56/ W L54 RDM 56/ D-10 RDM 56/ D-10 RDM 56/ D-10 RDM 56/ W-13 RDM 56/ W-16 RDM 56/ W-17 RDM 56/ W-13 RDM 56/ W-16 RDM 56/ W-21 RDM 56/ D-21 RDM 56/ HD L54 RDM 56/ HD-14 RDM 56/ HD-16 RDM 56/ HD-19 RDM 56/ HD-24 RDM 56/ W L54 RDM 56/ MD-28 RDM 56/ MD L54 RDM 56/ W L54 RDM 56/ HD L54 RDM 56/ W L WOLF ER SMOKE EXTRACT FANS

109 DV-2 ROOF EXTRACT FANS ROOF EXTRACT FANS 2 DV-2 Roof extract fan 2 ACCESSORIES WOLF

110 DV-2 ROOF EXTRACT FAN RG L54 Roof extract fans with fitted repair switch, for extracting stale air from rooms. Casing made from 100% recyclable plastic, colour: light grey (RAL 7035) With energy saving EC fans, variable speed control. 230V 400V Art. no , ,00 Art. no , ,00 Art. no , ,00 Art. no ,00 Art. no ,00 Art. no , WOLF ROOF EXTRACT FANS

111 ACCESSORIES for product Art. no. DG FLAT ROOF UPSTAND For flat roof installation plastic, RAL 7035, with insulation Height: 200mm DV L54 DV-2-250/DV L54 DV L54 DV L54 DV L54 FLAT ROOF UPSTAND, TALL For flat roof installation plastic, RAL 7035 Integration of a silencer possible Height 500 mm DV L54 Height 500 mm DV-2-250/DV L54 Height 500 mm DV L54 Height 700 mm DV L54 Height 700 mm DV L54 AUTOMATIC COVER FLAP FOR FLAT ROOF UP- STAND Zinc-plated sheet steel with plastic fins DV L54 DV-2-250/DV L54 DV L54 DV L54 DV L54 AUTOMATIC COVER FLAP FOR TALL FLAT ROOF UPSTAND Zinc-plated sheet steel with plastic fins DV L54 DV-2-250/DV L54 DV L54 DV L54 DV L54 09 INTAKE SILENCER Zinc-plated sheet steel for installation on intake side of roof extract fan Combination possible with flat roof upstand and tall flat roof upstand DV L54 DV-2-250/DV L54 DV L54 DV L54 DV L54 DUCT CONNECTING PLATE Zinc-plated sheet steel for connection of a round duct Ø 200 DV L54 Ø 250 DV L54 Ø 250 DV-2-250/DV L54 Ø 315 DV-2-250/DV L54 Ø 355 DV L54 Ø 400 DV L54 Ø 400 DV L54 Ø 450 DV L54 Ø 560 DV L WOLF DV-2 ROOF EXTRACT FANS

112 ACCESSORIES for product Art. no. DG SEALING PLATE Made from weather-resistant, closed-cell plastic for sealing the roof extract fan base, silencer and flat roof upstand DV L54 DV-2-250/DV L54 DV L54 DV L54 DV L54 CONNECTION PIECE Zinc-plated sheet steel to provide an airtight connection to the silencer/cover flap DV L54 DV-2-250/DV L54 DV L54 DV L54 DV L54 VARIABLE SPEED CONTROLLER For variable operation of one or more unit heaters with EC motor (0-10V) DV L WOLF DV-2 ROOF EXTRACT FANS

113 CWL / CWL-D COMFORT HOME VENTILATION SYSTEM COMFORT HOME VENTILATION SYSTEM 2 CWL-180 EXCELLENT CWL EXCELLENT CWL-T EXCELLENT CWL-F EXCELLENT Comfort domestic ventilation system with heat recovery Comfort domestic ventilation system with heat recovery Comfort domestic ventilation system with heat recovery Comfort domestic ventilation system with heat recovery DECENTRAL VENTILATION 6 CWL-D Decentralised ventilation unit with heat recovery ACCESSORIES CWL-D 7 WRS CONTROL SYSTEMS / CONTROL ACCESSORIES 8 WRS CONTROL SYSTEMS 8 CONTROL ACCESSORIES ACCESSORIES 11 ACCESSORIES 11 ISO PIPE SYSTEM 13 ROOF CONNECTIONS 14 OUTSIDEWALL CONNECTIONS AND SILENCER 15 AIR DISTRIBUTOR 17 FLEXIBLE HOSE SYSTEM, ROUND 19 ACCESSORIES FLEXIBLE HOSE SYSTEM ROUND AND FLAT DUCT FLAT DUCT SYSTEM EXCELLENT 22 AIR SUPPLY / EXTRACTION VALVES 24 FILTERS TECHNICAL DATA 26 CWL-180 EXCELLENT 26 CWL-300/400 EXCELLENT 27 CWL-T EXCELLENT 28 CWL-F EXCELLENT 29 CWL-D WOLF

114 CWL-180 EXCELLENT COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY RG H35 TYPE CWL Excellent 180 Energy efficiency class 1) Air flow rate at 150 Pa m³/h 180 Max. power consumption W Heat recovery efficiency max. % 92 Dimensions Duct connection diameter mm 125 Height mm 600 Width mm 560 Depth mm 315 Weight kg 25 4/0 L 4/0 R Art. no * Art. no * Delivery time on request 1) A with time switch and minimum one sensors 10 The comfort domestic ventilation system from WOLF offers energysaving and convenient ventilation all year. Suitable for apartments, detached houses, apartment blocks and offices. The heat in the extract air is extracted by the cross- and counterflow heat exchanger and supplied to the fresh supply air. Compact design for wall mounting Clean, pollen-free fresh air airing with your windows closed, excluding street noise (not only for those suffering from allergies) Removable cross countercurrent plate-type heat exchanger made from plastic Automatic frost stat control Constant flow fans Low energy consumption through DC fans BM-2 for operation(optional) Fully wired. Filter change requirement indicated at the device, the programming unit or at the 4-step switch WOLF COMFORT HOME VENTILATION SYSTEM

115 CWL EXCELLENT COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY RG H35 TYPE CWL Excellent Energy efficiency class 1) Air flow rate at 150 Pa m³/h Max. power consumption W Heat recovery efficiency max. % Dimensions Duct connection diameter mm Height mm Width mm Depth mm Weight kg /2 L 2/2 R 3/1 L 3/1 R 4/0 L 4/0 R * Delivery time on request 1) A+ with minimum two sensors Art. no Art. no * Art. no Art. no * Art. no Art. no The Comfort domestic ventilation system from WOLF offers energy saving and convenient ventilation all year round. Suitable for apartments, detached houses and apartment buildings. The heat in the extract air is extracted by the cross- and countercurrent heat exchanger and transferred to the fresh supply air. Compact design for wall mounting Clean, pollen-free fresh air airing with your windows closed, excluding street noise (not only beneficial for those suffering from allergies) Removable cross- and countercurrent heat exchanger made from plastic Automatic frost protection control Low energy consumption through DC fans BM-2 for operation (optional) Electric preheating coil 1000W integrated in the unit Bypass as standard G4/G7 filter grade as optional accessory Unit fully wired. Filter change indicator on the unit, the programming unit or at the 4-step switch. DIBt approval and Passive House certificate Constant flow fans WOLF COMFORT HOME VENTILATION SYSTEM

116 CWL-T EXCELLENT COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY RG H35 TYPE CWL-T Excellent 300 Energy efficiency class 1) Max. air flow rate at 150 Pa m³/h 300 Max. power consumption W Heat recovery efficiency max. % 93 Dimensions Duct connection diameter mm 160 Height mm 1288 Width mm 475 Depth mm 586 Weight kg 50 4/0 L Art. no ) A+ with minimum two sensors 10 The Comfort domestic ventilation system from WOLF offers energy saving and convenient ventilation all year round. Suitable for apartments, detached houses and apartment buildings. The heat in the extract air is extracted by the cross- and countercurrent heat exchanger and transferred to the fresh supply air. Compact design for floorstanding installation Clean, pollen-free fresh air airing with your windows closed, excluding street noise (not only beneficial for those suffering from allergies) Removable cross- and countercurrent heat exchanger made from plastic Bypass as standard Automatic frost protection control Constant flow fans Low energy consumption through DC fans Incl. trap Electric preheating coil 1000W integrated in the unit G4/F7 filter grade as optional accessory Fully wired. Filter change indicator on the programming unit or the 4-step switch DIBt approval and Passive House certificate applied for Hydraulic reheating coil (optional) Note: BM-2 is required for operation WOLF COMFORT HOME VENTILATION SYSTEM

117 CWL-F EXCELLENT COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY RG H35 TYPE CWL-F Excellent Energy efficiency class 1) Air flow rate at 150 Pa m³/h Max. power consumption W Heat recovery efficiency max. % Dimensions Duct connection diameter mm Height mm Width mm Depht mm Weight kg without preheater with preheater Art. no * Art. no * Delivery time on request 1) CWL-F-150 Excellent in combination with BM-2 CWL-F-300 Excellent A+ with minimum two sensors The Comfort domestic ventilation system with integral bypass from WOLF offers energy saving and convenient ventilation all year round. Suitable for apartments, detached houses and apartment buildings. The heat in the extract air is extracted by the cross- and countercurrent heat exchanger and transferred to the fresh supply air. Compact design for ceiling and wall mounting Clean, pollen-free fresh air airing with your windows closed, excluding street noise (not only beneficial for those suffering from allergies) Removable cross- and countercurrent heat exchanger made from plastic Bypass as standard Automatic frost protection control Constant flow fans Low energy consumption through DC fans For CWL-F-150 Excellent, electric preheating coil 375W integrated in the unit G4/G7 filter grade as optional accessory Unit fully wired. Filter change indicator on the unit, the programming unit or at the 4-step switch. DIBt approval and Passive House certificate Note: BM-2 is required for operation WOLF COMFORT HOME VENTILATION SYSTEM

118 CWL-D DECENTRALISED VENTILATION UNIT WITH HEAT RECOVERY RG H35 TYPE CWL-D 70 Energy efficiency class Air flow rate m³/h 70 Heat recovery efficiency max. % 87 Dimensions Diameter unit mm 250 Tapping drill hole Ø mm 260 (with 3 fall towards the outside) for wall thicknesses with accessories mm for wall thickness not incl. accessories mm Weight kg 14 Outside wall hood stainless steel Outside wall hood white (RAL9010) Art. no Art. no White internal panel Electric preheating coil 175W integrated in the unit 10 Clean, pollen-free fresh air airing with your windows closed, excluding street noise (not only beneficial for those suffering from allergies) Removable plastic countercurrent heat exchanger Bypass as standard G4/F7 filter grade as optional accessory for supply air Unit fully wired. Filter change indicator on the unit DIBt approval applied for Automatic frost protection control Low energy consumption through DC fans WOLF DECENTRAL VENTILATION

119 ACCESSORIES CWL-D Art. no. DG EXTENSION 50 MM For wall thicknesses mm White (RAL 9010) H36 Stainless steel H36 EXTENSION 100 MM For wall thicknesses mm White (RAL 9010) H36 Stainless steel H36 EXTENSION 150 MM For wall thicknesses mm White (RAL 9010) H36 Stainless steel H36 EXTENSION 200 MM For wall thicknesses mm White (RAL 9010) H36 Stainless steel H36 ADDITIONAL PCB (Required for connecting sensors) H36 INTERNAL CO2 SENSOR H36 10 INTERNAL MOISTURE SENSOR H36 ON/OFF SWITCH (OPTIONAL) (Zusatzplatine nicht nötig) H36 G4 FILTER SET (2xG4 + 1xG4 Ø180) H36 F7 FILTER SET (2xG4 + 1xF7 Ø180) H WOLF DECENTRAL VENTILATION

120 WRS CONTROL SYSTEMS for product Art. no. DG BM-2 PROGRAMMING UNIT Room temperature-dependent/weather-compensated controller With time program for heating and DHW Without outside temperature sensor, BM-2 black Incl. outside temperature sensor, BM-2 white Note: Required for the operation in accordance with EnEV. CWL Excellent, CWL-F/T-Excellent CWL Excellent, CWL-F/T-Excellent H H41 WALL MOUNTING BASE FOR BM-2 For using the BM-2 programming unit as a remote control BM H41 Black WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

121 CONTROL ACCESSORIES for product Art. no. DG AIR QUALITY SENSOR (VOC) Mixed gas sensor to measure the air quality; output signal 0-10V, power supply 24V With the CWL-180 Excellent and CWL-F-300 Excellent, extension kit for additional functions is required, part no CWL Excellent, CWL-F/T-Excellent H41 HUMIDITY SENSOR For measuring the relative humidity; output signal 0-10V, power supply 24V With the CWL-180 Excellent and CWL-F-300 Excellent, extension kit for additional functions is required, part no CWL Excellent, CWL-F/T-Excellent H41 SURFACE MOUNTED CO2 SENSOR For measuring the CO 2 content, output signal 0-10V, power supply 24V With the CWL-180 Excellent and CWL-F-300 Excellent, extension kit for additional functions is required, part no CWL Excellent, CWL-F/T-Excellent H41 NEW FLUSH MOUNTED EBUS CO2 SENSOR For measuring the CO 2 content, output signal 0-10V, power supply 24V With the CWL-180 Excellent and CWL-F-300 Excellent, extension kit for additional functions is required, part no WOLF LINK PRO - LAN / WLAN INTERFACE MODU- LE EXTERNAL Consisting of: ISM7e / WOLF Link Pro interface module, installation / operating instructions, ebus cable, power supply unit, network cable CWL Excellent, CWL-F/T-Excellent CWL Excellent, CWL-F/T-Excellent CFL, CKL, CRL H H41 LAN and WLAN interface module for wall mounting or mobile use of Wolf heating and ventilation devices Connection of WOLF heating appliances to the WOLF Smartset portal / app Use for parameterising compatible WOLF devices Power supply via power supply unit or USB 10 KNX EXTERNAL INTERFACE KIT Interface kit for integration of WOLF ventilation units into a KNX network Consisting of: Interface module ISM8e, KNX-IP-BAOS module, installation and operating instructions, network cable CWL Excellent, CWL-F/T-Excellent H41 MODBUS EXTERNAL INTERFACE KIT Interface kit for integration of WOLF ventilation units into a Modbus network (RS 485) CWL Excellent, CWL-F/T-Excellent H WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

122 CONTROL ACCESSORIES for product Art. no. DG EXTENSION KIT FOR ADDITIONAL FUNCTIONS 9-pole plug-in connection for connecting a reheating coil air quality sensor humidity sensor smoke detector CWL-180 Excellent, CWL-F-300 Excellent H41 RJ12 MODULAR DISTRIBUTOR Consisting of: Cable and splitter CWL Excellent, CWL-F/T-Excellent, CWL-D H41 RH DUCT SENSOR For measuring relative humidity CWL Excellent, CWL-F/T-Excellent H41 CONNECTION KIT For RH duct sensor part no Reducer DN200 to DN180 RH-Duct work sensor H41 CWL SERVICE TOOL For an straightforward parameter settings Free software can be found on our homepage. CWL Excellent, CWL-F/T-Excellent H41 4-STAGE SWITCH WITH FILTER REPLACEMENT INDICATOR CWL Excellent, CWL-F/T-Excellent, CWL-D H41 Note: Connecting cable, black necessary. 10 SURFACE MOUNTED HOUSING FOR 4-STAGE SWITCH CWL Excellent, CWL-F/T-Excellent, CWL-D H41 BLACK CONNECTING CABLE For 4-step switch 5 metres (2 x RJ12/6) CWL Excellent, CWL-F/T-Excellent, CWL-D metres (2 x RJ12/6) CWL Excellent, CWL-F/T-Excellent, CWL-D metres (2 x RJ12/6) CWL Excellent, CWL-F/T-Excellent, CWL-D H H H WOLF WRS CONTROL SYSTEMS / CONTROL ACCESSORIES

123 ACCESSORIES for product Art. no. DG ELECTRICAL PREHEATING COIL 1000 W DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-F-300 Excellent H36 ELECTRICAL REHEATING COIL 1000 W Extension kit for additional functions with the CWL-180 Excellent and CWL-F-300 Excellent art. no is required A DN160/125 reducer art. no is required with the CWL-180 Excellent DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-300-Excellent, H36 CWL-F/T-300-Excellent DN180 CWL-400 Excellent H36 ENTHALPY HEAT EXCHANGER FOR MOISTURE RECOVERY CWL-300/400 Excellent H36 CWL-F-300 Excellent H36 HYDRAULIC REHEATING COIL 3000W Incl. flow valve with thermostatic head, remote sensor, automatic air vent valve and corrugated stainless steel pipes CWL-T Excellent H36 CONDENSATE PUMP WITH POTENTIAL-FREE, FUL- LY WIRED ALARM OUTPUT Consisting of: Condensate pump with floating alarm output, condensate tank with lid and wall retainer, PVC hose 10mm (6m long), non-return valve, condensate inlet adaptor TLHK-EC, TLHK, CWL Excellent, CWL-F/T-Excellent, COB, TOB H40 10 SUMMER CASSETTE Alternative to in-line heat exchangers without heat recovery CWL-180 Excellent H36 TRAP Effective height 90mm CWL-300/400 Excellent H WOLF ACCESSORIES

124 ACCESSORIES for product Art. no. DG BALL TRAP CWL-300/400 Excellent, CWL-T-300 Excellent H36 BALL TRAP CWL-F-150 Excellent, CWL-F-300 Excellent H WOLF ACCESSORIES

125 ISO PIPE SYSTEM for product Art. no. DG INSULATED DUCT Length 200mm DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN180 CWL-400 Excellent H36 INSULATED DUCT 90 BEND DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN180 CWL-400 Excellent H36 INSULATED DUCT 45 BEND DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN180 CWL-400 Excellent H36 INSULATED DUCT TEE DN125 DN160 CWL-180 Excellent, CWL-F-150 Excellent CWL-300-Excellent, CWL-F/T-300-Excellent H H36 INSULATED DUCT Y-PIECE 45 CWL-400 Excellent H36 DN180 INSULATED DUCT REDUCER DN160/125 DN180/160 DN180/125 CWL-Excellent, CWL-F/T-Excellent CWL-Excellent, CWL-F/T-Excellent CWL-Excellent, CWL-F/T-Excellent H H H36 10 LOCKING RING FOR INSULATED DUCT One locking ring is required for each connection DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN180 CWL-400 Excellent H36 INSTALLATION KNIFE WITH SPECIAL SERRATED BLADE For trimming pipes to length quickly and cleanly CWL-Excellent, CWL-F/T-Excellent H WOLF ACCESSORIES

126 ROOF CONNECTIONS for product Art. no. DG THERMALLY INSULATED ROOF OUTLET Length 1159mm DN125, black CWL-180 Excellent, H36 CWL-F-150 Excellent DN125, red CWL-180 Excellent, H36 CWL-F-150 Excellent DN160, black CWL-300-Excellent, H36 CWL-F/T-300-Excellent DN160, red CWL-300-Excellent, H36 CWL-F/T-300-Excellent DN180, black CWL-400 Excellent H36 SEALING COLLAR FOR ROOF OUTLET CWL-Excellent, CWL-F/T-Excellent H36 UNIVERSAL ROOF TILE 25 TO 45 Black CWL-180 Excellent, H36 CWL-300 Excellent, CWL-F-150 Excellent, CWL-F-300 Excellent Red CWL-180 Excellent, H36 CWL-300 Excellent, CWL-F-150 Excellent, CWL-F-300 Excellent Black CWL-400 Excellent H36 UBBIFLEX HIGH TACK ADHESIVE For fixing the CWL universal roof tile to tiles or the roof CWL-Excellent, CWL-F/T-Excellent H36 10 FLAT ROOF OUTLET 0 DN160 CWL-180 Excellent, H36 CWL-300 Excellent, CWL-F-150 Excellent, CWL-F/T-300 Excellent DN180 CWL-400 Excellent H36 FASTENING CLIP FOR INSULATED DUCT DN125 CWL-180 Excellent, H36 CWL-F-150 Excellent DN160 CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN180 CWL-400 Excellent H WOLF ACCESSORIES

127 OUTSIDEWALL CONNECTIONS AND SILENCER for product Art. no. DG WALL HOOD DN125, black (RAL 9005) CWL-180 Excellent, H36 CWL-F-150 Excellent DN125, white (RAL 9010) CWL-180 Excellent, H36 CWL-F-150 Excellent DN160, black (RAL 9005) CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN160, white (RAL 9010) CWL-300-Excellent, H36 CWL-F/T-300-Excellent, SWP DN180, black (RAL 9005) CWL-400 Excellent H36 DN180, white (RAL 9010) CWL-400 Excellent H36 NEW FROM 03/2018 ON DOUBLE GRILLE For outdoor and exhaust air DN125, white DN125, Stainless steel DN160, white DN160, Stainless steel CWL-180 Excellent, CWL-F-150 Excellent CWL-180 Excellent, CWL-F-150 Excellent CWL-300-Excellent, CWL-F/T-300-Excellent CWL-300-Excellent, CWL-F/T-300-Excellent H H H H36 NEW SILENCER For supply air or extract air 50mm insulation NEW FROM 03/2018 ON DN125, Length 1000mm CWL-180 Excellent, H36 CWL-F-150 Excellent DN125, Length 500mm CWL-180 Excellent, H36 CWL-F-150 Excellent DN160, Length 1000mm CWL-300-Excellent, H36 CWL-F/T-300-Excellent DN180, Length 500mm CWL-300-Excellent, H36 CWL-F/T-300-Excellent DN180, Length 1000mm CWL-400 Excellent H36 DN160, Length 500mm CWL-400 Excellent H36 FLEXIBLE SILENCER For supply air or extract air 50mm insulation DN125, Length 1000m CWL-180 Excellent, H36 CWL-F-150 Excellent DN160, Length 1000m CWL-300-Excellent, H36 CWL-F/T-300-Excellent DN180, Length 1000m CWL-400 Excellent H36 10 SILENCER Metal, for supply air and extract air Sound attenuating material, closed cell to DIN DN125, Length 482 mm CWL-F-150 Excellent H36 DN160, Length 600 mm CWL-F-300 Excellent H36 SILENCER AND FLOW RATE CONTROLLER For DN125 connector CWL Excellent, CWL-T/F-Excellent H WOLF ACCESSORIES

128 OUTSIDEWALL CONNECTIONS AND SILENCER for product Art. no. DG SILENCER AND FLOW RATE CONTROLLER For floor grille connector CWL Excellent, CWL-T/F-Excellent H WOLF ACCESSORIES

129 AIR DISTRIBUTOR for product Art. no. DG AIR DISTRIBUTOR DN Plastic, for supply air or extract air, antistatic and antibacterial An adaptor is required to connect hose or flat duct systems DN63, 50x100 and 50x140 to the air distributor. 8 DN75 connectors with 4 locking caps CWL Excellent CWL-F/T-Excellent 16 DN75 connectors with 8 locking caps CWL Excellent CWL-F/T-Excellent 24 DN75 connectors with 12 locking caps CWL Excellent CWL-F/T-Excellent H H H36 Note: Click and seal ring DN75 required. NEW FROM 03/2018 ON AIR DISTRIBUTOR MINI connection ISO pipe DN125 CWL Excellent CWL-F/T-Excellent connection ISO pipe DN125 CWL Excellent CWL-F/T-Excellent connection ISO pipe DN CWL Excellent CWL-F/T-Excellent connection ISO pipe DN CWL Excellent CWL-F/T-Excellent H H H H36 ADAPTOR DN63 For connection to the air distributor DN , plastic, antistatic and antibacterial Note: Click and seal ring DN63 required. CWL Excellent CWL-F/T-Excellent H36 10 ADAPTOR FOR FLAT DUCT 50X100 For connection to the air distributor DN , plastic, antistatic and antibacterial Note: Seal ring 50x100 required. CWL Excellent CWL-F/T-Excellent H36 ADAPTOR FOR FLAT DUCT 50X140 For connection to the air distributor DN , plastic, antistatic and antibacterial Note: Seal ring 50x140 required. CWL Excellent CWL-F/T-Excellent H36 RESTRICTOR DN75 For air distributor DN , plastic, antistatic and antibacterial, bag of 10 CWL Excellent CWL-F/T-Excellent H WOLF ACCESSORIES

130 AIR DISTRIBUTOR for product Art. no. DG CLOSING CAP DN75 for air distributor DN , plastic, antistatic and antibacterial, bag of 10 CWL Excellent CWL-F/T-Excellent H36 CONNECTION DN For air distributor DN , plastic, antistatic and antibacterial CWL Excellent CWL-F/T-Excellent H36 INSPECTION CAP For air distributor DN , plastic, antistatic and antibacterial CWL Excellent CWL-F/T-Excellent H36 NEW FROM 03/2018 ON ADJUSTABLE RESTRICTOR V EASY CWL air distributor H36 SILENCER KIT For air distributor DN , plastic, consisting of 10 push-fit elements, closed-cell sound attenuating material acc. to DIN CWL Excellent CWL-F/T-Excellent H WOLF ACCESSORIES

131 FLEXIBLE HOSE SYSTEM, ROUND for product Art. no. DG AIR DISTRIBUTION HOSE With smooth internal surface DN63, 50m roll DN75, 50m roll DN63, 50m roll, antistatic and antibacterial DN75, 50m roll, antistatic and antibacterial CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H H H36 90 BEND For CWL air distribution hose Antistatic and antibacterial DN63 CWL Excellent H36 DN75 CWL H36 CLICK CONNECTOR FOR AIR DISTRIBUTION HOSE Antistatic and antibacterial DN63 DN75 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 Note: Click ring and seal ring DN63 or DN75 required. SEAL RING DN63, bag of 10 DN75, bag of 10 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 CLICK RING Antistatic and antibacterial DN63, bag of 10 DN75, bag of 10 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 10 CLICK CONNECTOR KIT FOR AIR DISTRIBUTION HOSE Antistatic and antibacterial Consisting of: 5 click connectors for air distribution hose 10 seal rings 10 click rings DN63 DN75 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H WOLF ACCESSORIES

132 L WOLF FLEXIBLE HOSE SYSTEM, ROUND for product Art. no. DG NEW FROM 03/2018 ON AIR DISTRIBUTOR Metal, for supply air and extract air Incl. silencer For direct installation onto the CWL-F Excellent Sound attenuating material, closed cell to DIN DN125: 2x10 connectors DN75 with 5 pipe caps each Length 482mm DN125: 2x10 connectors DN63 with 5 pipe capes eache Length 482mm DN160: 2x9 connectors DN75 with 5 pipe caps each Length 600mm DN160: 2x9 connectors DN63 with 5 pipe capes each Length 600mm CWL-F-150 Excellent H36 CWL-F-150 Excellent H36 CWL-F-300 Excellent H36 CWL-F-300 Excellent H36 Note: Seal ring DN75/63 required. CONNECTOR FOR DN125 VENT, ONE PIPE CAP AND TWO PIPE SOCKETS, Incl. cover connector for vent DN125, antistatic and antibacterial DN63, L = 325mm DN75, L = 325mm CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 Note: Click and seal ring required. L FLOOR GRILLE CONNECTOR One pipe cap and two pipe connectors, antistatic and antibacterial CWL Excellent CWL-F/T-Excellent H36 DN75, L = 300mm Note: Click and seal ring required. For DN63, use DN63 adaptor. 10 PIPE CAP FOR AIR DISTRIBUTION HOSE Antistatic and antibacterial DN63 DN75 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 LUBRICANT TUBE Content 50ml H WOLF ACCESSORIES

133 ACCESSORIES FLEXIBLE HOSE SYSTEM ROUND AND FLAT DUCT for product Art. no. DG EXTENSION FOR CONNECTOR DN125 Length = 150mm CWL Excellent CWL-F/T-Excellent H36 COVER CONNECTOR FOR DN125 VENT Bag of 10 Ventil DN H36 90 ADAPTOR FROM ROUND DN75 TO FLAT DUCT 50X100 Antistatic and antibacterial Note: Click and seal ring required. CWL Excellent CWL-F/T-Excellent H36 ANGLE ADAPTOR 2X ROUND DN75 TO 1X FLAT DUCT 50X140 Antistatic and antibacterial Note: Click and seal ring DN75 required H36 UNIVERSAL CLIP FOR FLAT DUCT 50X100, 50X140 AND ROUND DUCT Ø 63MM AND Ø 75MM 10 pce CWL Excellent CWL-F/T-Excellent H WOLF ACCESSORIES

134 FLAT DUCT SYSTEM EXCELLENT for product Art. no. DG FLAT DUCT With smooth internal surface, antistatic and antibacterial 50x100, 50m roll CWL Excellent CWL-F/T-Excellent 50x140, 20m roll CWL Excellent CWL-F/T-Excellent H H36 LOCKING CAP FOR FLAT DUCT Antistatic and antibacterial 50x100 bag of 10 50x140 bag of 10 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 90 BEND CWL FOR FLAT DUCT Antistatic and antibacterial 50x100 vertical 50x140 vertical CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 Note: Seal ring required. 90 BEND CWL FOR FLAT DUCT Antistatic and antibacterial 50x100 horizontal 50x140 horizontal CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 Note: Seal ring required. CLICK CONNECTOR FOR FLAT DUCT Antistatic and antibacterial 10 50x100 50x140 Note: Seal ring required. CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 SEALING RING FOR FLAT DUCT Antistatic and antibacterial CWL Excellent CWL-F/T-Excellent H36 50x100 bag of 10 SEALING RING FOR FLAT DUCT Antistatic and antibacterial CWL Excellent CWL-F/T-Excellent H36 50x140 bag of 10 PIPE CAP FOR MOULDED COMPONENT Antistatic and antibacterial 50x100 50x140 CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H WOLF ACCESSORIES

135 L L WOLF FLAT DUCT SYSTEM EXCELLENT for product Art. no. DG AIR DISTRIBUTOR Metal, for supply air and extract air Incl. silencer for direct installation onto the CWL-F-Excellent Sound attenuating material, closed cell to DIN DN125: 2x6 connectors 50x100 with 3 pipe caps each Length 482mm DN160: 2x9 connectors 50x100 with 5 pipe caps each Length 600mm CWL-F-150 Excellent H36 CWL-F-300 Excellent H36 Note: Seal ring 50x100 required. RESTRICTOR FOR FLAT DUCT Antistatic and antibacterial CWL-F Excellent H36 50x100 bag of 10 CONNECTOR FOR VENT DN125 Two duct connectors and one pipe cap, antistatic and antibacterial, incl. cover connector for vent DN125 Length L = 240mm 50x Length L = 330mm 50x CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H36 Note: Seal ring 50x100 or 50x140 required. FLOOR GRILLE CONNECTOR One or two duct connectors and one pipe cap, antistatic and antibacterial Incl. cover Length L = 220mm CWL Excellent CWL-F/T-Excellent H36 50x100 (two duct connectors) Note: Seal ring 50x100 required. L FLOOR GRILLE CONNECTOR One or two duct connectors and one pipe cap, antistatic and antibacterial Incl. cover Length L = 240mm CWL Excellent CWL-F/T-Excellent H x140 (one duct connector) Note: Seal ring 50x140 required. FLOOR GRILLE, METAL White Stainless steel CWL Excellent CWL-F/T-Excellent CWL Excellent CWL-F/T-Excellent H H WOLF ACCESSORIES

136 AIR SUPPLY / EXTRACTION VALVES for product Art. no. DG SUPPLY AIR VENT, PLASTIC, DN125 Incl. installation frame with rubber lip gasket CWL Excellent CWL-F/T-Excellent H36 SUPPLY AIR VENT, METAL, DN125 Incl. installation frame with rubber lip gasket CWL Excellent CWL-F/T-Excellent H36 EXTRACT AIR VENT, PLASTIC, DN125 Incl. installation frame with rubber lip gasket CWL Excellent CWL-F/T-Excellent H36 EXTRACT AIR VENT, METAL, DN125 Incl. installation frame with rubber lip gasket CWL Excellent CWL-F/T-Excellent H36 FILTER BAGS (5 pce) CWL Excellent CWL-F/T-Excellent H36 KITCHEN EXTRACT AIR VENT WITH G3 FILTER (RAL 9010) CWL Excellent CWL-F/T-Excellent H36 CLASS G3 FILTER MATT CLASS 5 pce, 200 x 190mm Kitchen extract air valve H36 COMMISSIONING CWL Prices: net Without air adjustment With air adjustment WOLF ACCESSORIES

137 FILTERS for product Art. no. DG FILTER SERVICE SET Outdoor or extract air filter Class G4 295 x 140mm, 2 pce CWL-180, H36 CWL-180 Excellent 415 x 237mm, 2 pce CWL-300, CWL H x 237mm, 50 pce CWL-300, CWL H x 184mm, 2 pce CWL-300 Excellent, H36 CWL-400 Excellent 522 x 184mm, 50 pce CWL-300 Excellent, H36 CWL-400 Excellent 173 x 141mm, 2 pce CWL-F-150 Excellent H x 177mm, 2 pce CWL-F-300 Excellent H x 166mm, 2 pce CWL-T-300 Excellent H36 FILTER SERVICE SET FOR BYPASS Outdoor or extract air filter Class G4 500 x 237mm, 2 pce CWL-300 B, CWL-400 B H x 237mm, 50 pce CWL-300 B, CWL-400 B H36 FILTER SERVICE SET Outdoor air filter Class M6 415 x 237mm, 2 pce CWL-300, CWL H x 237mm, 2 pce CWL-300 B, CWL-400 B H36 FILTER SERVICE SET Outdoor air filter Class F7 295 x 140mm, 2 pce CWL-180, H36 CWL-180 Excellent 522 x 184mm, 2 pce CWL-300/400 Excellent H x 132mm, 2 pce CWL-F-150 Excellent H x 166mm, 2 pce CWL-F/T-300 Excellent H36 COMBI SERVICE SET, ACTIVATED CHARCOAL FIL- TER Outdoor air filter Class M6 522 x 184mm (2 pce) CWL-300/400 Excellent H WOLF ACCESSORIES

138 TECHNICAL DATA COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY CWL-180 Excellent A B C TYPE CWL CWL-180 Excellent max. fan power at 150 Pa m³/h 180 Heat recovery efficiency max. % 92 Height A mm 600 Width B mm 560 Depth C mm 315 Duct connection diameter mm 125 Filter G4 Power factor Cos φ 0,44-0,67 Electricity consumption W Electrical power consumption W 64 (without preheater) (at 150m³/h and 100 Pa) Weight kg 25 Protection class IP 30 Electrical connection 230 V / 50 Hz Connection 4/0 L Connection 4/0 R 10 B A C E 3 4 I G F A B F I 4 E 3 G C H L H 6 6 J M K J D K M L D 1 Supply air (living room) 2 Exhaust air (to the outside) 3 Extract air (living room) 4 Outdoor air (from outside) 5 Electrical connection 6 Drain connection Type A B C D E F G H I J K L M CWL-180 Excellent R/L WOLF CWL / CWL-D COMFORT HOME VENTILATION SYSTEM

139 TECHNICAL DATA COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY CWL-300/400 Excellent TYPE CWL CWL-300 Excellent CWL-400 Excellent max. fan power at 150 Pa m³/h 300 w400 Heat recovery efficiency max. % Height A mm Width B mm Depth C mm Duct connection diameter mm Filter G4 G4 (F7 as accessory) F7 as accessory) Power factor Cos φ 0,37-0,51 0,38-0,61 Electrical power consumption W Electrical power consumption W (without preheater) (at 225m³/h and 100 Pa) (at 300m³/h and 100 Pa) Weight kg Protection class IP Electrical connection 230 V / 50 Hz 230 V / 50 Hz 2 A I Connection 4/0 R B 6 C G D J K L C B A H 2 A I Connection 2/2 R C D G 4 3 C A H J C B K L 2 Connection 3/1 R (only CWL-400 Excellent) A I C 3 4 G D J B K L C B A H 3 A Connection 4/0 L B C G D C Connection 2/2 L B C D G C Connection 3/1 L C A D G C 10 1 B A B B I 6 J K L H 3 6 I C 1 J A K L C H I 6 1 J A K L H C 1 Supply air (living room) 2 Exhaust air (to the outside) 3 Extract air (living room) 4 Outdoor air (from outside) 5 Electrical connection 6 Drain connection Type A B C D G H I J K L CWL-300/400 Excellent R CWL-300/400 Excellent L WOLF CWL / CWL-D COMFORT HOME VENTILATION SYSTEM

140 TECHNICAL DATA COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY CWL-T Excellent D A B C TYPE CWL CWL-T-300 max. fan power at 150 Pa m³/h 300 Heat recovery efficiency max. % 93 Height A mm 1287,5 Width B mm 475 Depth C mm 585 Duct connection diameter D mm 160 Filter G4 (F7 as accessory) Power factor Cos φ 0,32-0,43 Electricity consumption W Electrical power consumption W 86 (without preheater) (at 225m³/h and 100 Pa) Weight (with bypass) kg 50 Protection class IP 20 Electrical connection 230 V / 50 Hz Connection 4/0 L 10 E F G H J I 1 Supply air (living room) 2 Exhaust air (to the outside) 3 Extract air (living room) 4 Outdoor air (from outside) 5 Electrical connection 6 Drain connection Type A B C D E F G H I J CWL-T-300 Excellent 1287, WOLF CWL / CWL-D COMFORT HOME VENTILATION SYSTEM

141 TECHNICAL DATA COMFORT DOMESTIC VENTILATION SYSTEM WITH HEAT RECOVERY CWL-F Excellent B C A TYPE CWL CWL-F-150 Excellent CWL-F-300 Excellent max. fan power at 150 Pa m³/h Heat recovery efficiency max. % Height A mm Width B mm Depth C mm Duct connection diameter mm Filter G4 G4 (F7 as accessory) (F7 as accessory) Power factor Cos φ 0,34-0,49 0,39-0,53 Electricity consumption W Electrical power consumption W (without preheater) (at 125m³/h and 150 Pa) (at 225m³/h and 150 Pa) Weight kg Protection class IP Electrical connection 230 V / 50 Hz 230 V / 50 Hz B E D C D E F A D E G D E H 1 Supply air (living room) 2 Exhaust air (to the outside) 3 Extract air (living room) 4 Outdoor air (from outside) 5 Electrical connection 6 Drain connection Type A B C D E F G H CWL-F-150 Excellent CWL-F-300 Excellent WOLF CWL / CWL-D COMFORT HOME VENTILATION SYSTEM

142 TECHNICAL DATA DECENTRALISED VENTILATION UNIT WITH HEAT RECOVERY CWL-D C D B E A F G TYPE CWL CWL-D-70 Air volume at stage 1 / 2 / 3 / 4 / 5 m³/h 15 / 25 / 40 / 55 / 70 Heat recovery efficiency max. % 87 Diameter unit connection mm 250 Filter 2x G4 (extract air) & 1x G4 (supply air) Width kg 14 Protection class IP Indoor unit IP20 / front cover IPX4 Electrical connection 230 V / 50 Hz Type A B C D E F G CWL-D WOLF CWL / CWL-D COMFORT HOME VENTILATION SYSTEM

143 CGL COMFORT LARGE AREA VENTILATION UNITS COMFORT LARGE AREA VENTILATION UNITS 2 CGL Comfort large area ventilation unit 2 WRS CONTROL SYSTEMS / CONTROL ACCESSORIES 3 ACCESSORIES 4 ACCESSORIES 4 INTAKE / DISCHARGE ACCESSORIES 5 COMMISSIONING 6 TECHNICAL DATA 7 CGL WOLF

144 CGL COMFORT LARGE AREA VENTILATION UNIT RG L55 TYPE CGL Recommended air volume m³/h 600 with externally available duct pressure of approx. Power consumption Pa. 550 with an air volume of 500m³/h W 90 with an air volume of 600m³/h W 135 Sound pressure level 1 m in front of the device with an air volume of 500m³/h db(a) 37 with an air volume of 600m³/h db(a) 40 Dimensions Width mm 1017 Depth mm 508 Height mm 2137 Weight basic unit kg 250 CGL le CGL ri Art. no. on request on request Art. no. on request on request Note: Only possible in connection with BML ventilation control module for CGL. 11 The Comfort large area ventilation unit from WOLF offers energy saving and convenient ventilation all year round. Suitable for classrooms, preschools, conference rooms, club premises, open plan offices and restaurants. Compact, inherently stable, height-adjustable casing made from powder-coated sheet steel (traffic white RAL 9016) High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption High efficiency cross- and countercurrent heat exchanger made from aluminium for heat recovery. Heat is extracted from the extract air and transferred to the fresh air. With integral bypass for night ventilation in summer. Microprocessor-based control for fans, heat recovery and temperature, wired as standard Base for BML ventilation programming unit for CGL fitted and wired in the unit Flow-optimised splitter silencer for supply and extract air Easily replaceable compact panel filters: F7 supply air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) WOLF COMFORT LARGE AREA VENTILATION UNITS

145 WRS CONTROL SYSTEMS / CONTROL ACCESSORIES Art. no. DG BML VENTILATION PROGRAMMING UNIT FOR CGL Only one BML ventilation control module for CGL is needed to actuate up to 7 CGL devices Mounted optionally in the CGL device or in the wall holder as a remote control L55 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 CO2 SENSOR Required for CO 2 -controlled operation Fully wired, as control variable for the CO 2 -dependent control L55 ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables L WOLF CGL COMFORT LARGE AREA VENTILATION UNITS

146 ACCESSORIES Art. no. DG CONDENSATE PUMP Required if no free condensate drain is possible Consisting of: Fully wired condensate pump, float switch, alarm generator and bracket, up to 30l/h and PVC hose 8mm (5m long) L55 ELECTRIC PREHEATING COIL Recommended for optimised appliance operation Fully wired electric heating coil with high limit safety cut-out and bracket to protect the outdoor air filter against moisture penetration or as frost protection for the heat recovery system Output 1000W on request ELECTRIC REHEATING COIL, VARIABLE For increasing the supply air temperature at low outside temperatures; can be integrated into the unit as an option; electrical plug-in design Output 1000W on request TUBULAR END DAMPER DN250, MOTORISED (230 V; OPEN/CLOSE) Servomotor for connection on site L55 TUBULAR SILENCER DN250 Length: 600mm All-round insulation 50mm (attenuation 6dB / 250Hz) L WOLF ACCESSORIES

147 INTAKE / DISCHARGE ACCESSORIES for product Art. no. DG INTAKE SILENCER To attenuate the intake noise by up to 5dB with height-adjustable feet. Reduction of the total sound level 1m in front of the CGL by up to 3dB. Intake: left and right-hand side or back L55 UNIVERSAL INTAKE SECTION With height-adjustable feet. Intake: Left/right-hand side, back Ø 250mm Left/right-hand side 205 x 408mm Back 205 x 915mm L55 VERTICAL DISCHARGE SECTION WITH PIPE DAM- PER With sound attenuating casing. Discharge grille horizontally and vertically adjustable. Pipe damper connection Ø 250mm with servomotor 230V open/close 5Nm. CGL li L55 CGL re L55 VERTICAL DISCHARGE SECTION With sound attenuating casing. Discharge grille horizontally and vertically adjustable. Terminal box (230V) for on-site pipe dampers Pipe connection Ø 250mm CGL li L55 CGL re L55 HORIZONTAL DISCHARGE SECTION With sound attenuating casing. Discharge grille horizontally and vertically adjustable. Terminal box (230V) for any on-site pipe dampers Pipe connection Ø 250mm CGL li L55 CGL re L55 LIFTING GEAR For retrofitting the intake silencer L55 11 M5 COMPACT PANEL FILTER Fine dust filter 372mm x 393mm x 96mm L55 F7 COMPACT PANEL FILTER Fine dust and pollen filter 404mm x 592mm x 96mm L WOLF ACCESSORIES

148 COMMISSIONING Art. no. DG COMMISSIONING OF 1 BASIC DEVICE Appointment necessary (at least 8 working days before actual commissioning) Net price COMMISSIONING OF FURTHER ACCESSORIES Heating or cooling or multiple units on request WOLF ACCESSORIES

149 TECHNICAL DATA Connection side Supply air direction left ZUL FOL AUL SUP EHA ODA Connection side Supply air direction right AUL FOL ZUL ODA EHA SUP ABL ETA CGL COMFORT LARGE AREA VENTILATION UNIT Type CGL 1100 Wide mm 1017 Depth mm 508 Height mm 2137 ABL ETA WOLF CGL COMFORT LARGE AREA VENTILATION UNITS

150 NOTES WOLF CGL COMFORT LARGE AREA VENTILATION UNITS

151 CFL COMFORT FLAT VENTILATION UNIT COMFORT FLAT VENTILATION UNIT 2 CFL-WRG Comfort slimline ventilation unit with heat recovery CFL-EC Comfort slimline ventilation unit 3 CONTROL SYSTEMS / CONTROL ACCESSORIES 4 CFL-EC CONTROL SYSTEMS 4 CONTROL ACCESSORIES 5 ACCESSORIES 8 HEATER BANKS 8 CONNECTING ACCESSORIES 9 EXTENSION MODULE 10 DEVICE ACCESSORIES 13 COMMISSIONING 15 TECHNICAL DATA 16 UNIT WOLF

152 CFL-WRG COMFORT SLIMLINE VENTILATION UNIT WITH HEAT RECOVERY RG L57 TYPE CFL-WRG Air volume m³/h Dimensions Length mm Depth mm Hight mm Weight basic unit kg SUP ri SUP le SUP ri SUP le PWW PWW Electro Electro Art. no. on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request 12 The Comfort slimline ventilation unit from WOLF (ceiling unit operated from below) offers energy saving and convenient ventilation all year round. Suitable for conference rooms, club premises, open plan offices, restaurants, preschools, classrooms, etc. Casing: Zinc-plated sheet steel Appliance to VDI 6022 High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control (0-10V) via latest EC motor technology with low energy consumption High efficiency cross- and countercurrent heat exchanger made from aluminium for heat recovery. Heat is extracted from the extract air and transferred to the fresh air. With integral bypass for night ventilation in summer. Compact panel filter F7 (outdoor air) / M5 (extract air) Outside sensor, supply air sensor, extract air sensor, icing sensor, 2 x differential pressure switches for filter monitoring, wired as standard and installed in the unit CO 2 or air quality sensor can be optionally installed in the unit; electrical plug-in design WRS-K control unit fully wired BMK air handling programming unit supplied separately Integrated temperature control: Supply air temperature control (factory setting) Extract air control (adjustable on the programming unit) Room temperature control (adjustable on the programming unit) 1 set of mounting brackets (4 pce) supplied separately Incl. WRS-K control unit for switching a reheating coil, as well as a cooling coil or direct expansion coil Choice of PWW or electric for the reheating coil WOLF COMFORT FLAT VENTILATION UNIT

153 CFL-EC COMFORT SLIMLINE VENTILATION UNIT RG L57 TYPE CFL-EC Air volume m³/h Dimensions CRL-EC-ZUL Length mm CFL-EC-ZUL Depth mm CFL-EC-ZUL Height mm CRL-EC-ABL Length mm CFL-EC-ABL Depth mm CFL-EC-ABL Height mm Weight CFL-EC-ZUL Weight basic unit kg CFL-EC-ABL Weight basic unit kg SUP ri SUP le ETA ri ETA le Art. no. on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request NEW: CFL-EC-ABL can be used in combination with expansion modules as supply air units. The Comfort slimline ventilation unit from WOLF (ceiling unit operated from below) offers energy saving and convenient ventilation all year round. Suitable for conference rooms, club premises, open plan offices, restaurants, preschools, classrooms, etc. Casing: Zinc-plated sheet steel Appliance to VDI 6022 CFL-ZUL supply air unit with PWW heat exchanger incl. frost stat fitted as standard High efficiency, high performance radial fan with single sided intake and variable speed control (0-10V) via latest EC motor technology with low energy consumption EC fan pre-wired to terminal box Compact panel filter F7 (outdoor air) / M5 (extract air) With differential pressure switch for filter monitoring fitted as standard 1 set of mounting brackets (4 pce) supplied separately WOLF COMFORT FLAT VENTILATION UNIT

154 CFL-EC CONTROL SYSTEMS for product Art. no. DG BML VENTILATION PROGRAMMING UNIT Room temperature-compensated temperature control Graphic display with backlight Simple menu navigation through plain text display Operation using rotary knob with push-function 4 function keys for frequently used functions (information, temperature, speed setting, fresh air proportion) Mounted optionally in the ventilation module or in the wall holder as remote control Only one ventilation operating module BML is needed to operate up to 7 zones Demand-optimised boiler water temperature demand via ebus ebus interface L50 WALL MOUNTING BASE Wall mounting base for using the BML programming unit as a remote control H41 LM2 VENTILATION MODULE Ventilation module LM2 for controlling the room temperature by means of the rotation speed or the mixer control 2-stage motor control in connection with ventilation module LM1 or variable speed control via EC-motor Simple configuration of the controller by selecting predefined system diagrams Operation of the heat or cooling generator Demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management Ventilation operating module BML can be clipped on Mixed air flap control Induction louvre control L50 CONTROL PANEL For room temperature regulation via mixer control for PWW and PKW Control of a heat generator (PWW) and a chiller on request ISM 5 LON INTERFACE MODULE To connect ventilation modules LM1, LM2 and CGL to a building management system applying LON standard network variables L WOLF CONTROL SYSTEMS / CONTROL ACCESSORIES

155 CONTROL ACCESSORIES for product Art. no. DG AIR QUALITY SENSOR Mixed gas sensor to measure the air quality; plug-in design CFL-WRG L57 CO2 SENSOR Required for CO 2 -controlled operation, plug-in design CFL-WRG L57 OUTSIDE, CEILING OR ROOM TEMPERATURE SEN- SOR LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, LHD, TL- HD-EC, TLHD-K-EC, TLHD, TLHD-K, CFL-WRG, CFL- EC-ZUL, CKL, CRL H41 SUPPLY/EXTRACT AIR TEMPERATURE SENSOR, DUCT, LOOSE CFL-EC-ZUL CFL-EC-ABL CFL-WRG in connection with cooler extension module L57 DUCT HYGROSTAT, LOOSE With wall retainer CFL, CKL, CRL L57 ROOM HYGROSTAT Loose CFL, CKL, CRL L57 BMK-F REMOTE CONTROL Wall mounting CFL-WRG, CKL, CRL L56 LON INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 12 BACNET INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L WOLF CONTROL SYSTEMS / CONTROL ACCESSORIES

156 CONTROL ACCESSORIES for product Art. no. DG ETHERNET INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 MODBUS INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 KNX INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL on request NEW WOLF LINK PRO - LAN / WLAN INTERFACE MODU- LE EXTERNAL Consisting of: ISM7e / WOLF Link Pro interface module, installation / operating instructions, ebus cable, power supply unit, network cable LAN and WLAN interface module for wall mounting or mobile use of Wolf heating and ventilation devices Connection of WOLF heating appliances to the WOLF Smartset portal / app Use for parameterising compatible WOLF devices Power supply via power supply unit or USB CWL Excellent, CWL-F/T-Excellent CFL, CKL, CRL H41 BMK-T10 TOUCH PANEL Option of operating multiple appliances Installation at the front on site CFL-WRG, CKL, CRL L57 OMNIPOLAR REPAIR SWITCH AR6, LOOSE Lockable 5.5kW CFL L57 For increased electrical power 18.5kW CFL L57 OMNIPOLAR REPAIR SWITCH Fitted and wired in control panel CFL 10/15/22-WRG on request 12 VARIABLE SPEED CONTROLLER For variable operation of one or more unit heaters with EC motor (0-10V) LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L50 UNIVERSAL TIMER WITH 7-DAY PROGRAM LH-EC, TLH-EC, TLHD-EC, TLHD-K-EC, CFL-EC-ZUL, CFL-EC-ABL L WOLF CONTROL SYSTEMS / CONTROL ACCESSORIES

157 CONTROL ACCESSORIES for product Art. no. DG FLOW RATE CONTROL CFL 10, 15, L57 CFL L57 CONSTANT PRESSURE CONTROL CFL 10, 15, L57 CFL L WOLF CONTROL SYSTEMS / CONTROL ACCESSORIES

158 HEATER BANKS for product Art. no. DG ELECTRIC PREHEATING COIL 1 X 230V / 50HZ, SINGLE STAGE FOR FILTER PRE-DRYING Recommended for optimal operation of the unit 1000W; 1x230V / 50Hz CFL 10-WRG L W; 1x230V / 50Hz CFL 15-WRG L W; 1x230V / 50Hz CFL 22-WRG L W; 2x230V / 50Hz CFL 32-WRG L57 Note: Fully wired electric heating coil with high limit safety cut-out, frost stat and bracket to protect the outdoor air filter against moisture penetration or as frost protection for the heat recovery system ELECTRIC REHEATING COIL, VARIABLE (0-10 V) For increasing the supply air temperature at low outside temperatures; can be integrated into the unit as an option; electrical plug-in design 1000W, 1x230V/50Hz CFL 10-WRG-E L WOLF ACCESSORIES

159 CONNECTING ACCESSORIES for product Art. no. DG INSULATING FRAME Length 70mm For connection to duct 409 x 247mm CFL L x 247mm CFL L x 291mm CFL L x 354mm CFL L57 FLEXIBLE CONNECTION, 4-HOLE PROFILE FRAME Length 130mm For connection to duct 405 x 243mm CFL L x 243mm CFL L x 287mm CFL L x 350mm CFL L57 Optional: Flexible connection in thermally insulated version, Insulation sickness 10mm ADAPTOR MODULE For square to round connection Connection diameter 250mm, length 130mm CFL L57 Connection diameter 250mm, length 130mm CFL L57 Connection diameter 315mm, length 130mm CFL L57 Connection diameter 450mm, length 300mm CFL L57 LOUVRE DAMPER Length 140mm For duct Zinc-plated sheet steel Tightness category 2 to EN x 256mm CFL L x 256mm CFL L x 306mm CFL L x 370mm CFL L WOLF ACCESSORIES

160 EXTENSION MODULE for product Art. no. DG SILENCER EXTENSION MODULE Can be fitted to the unit as an option With filter insert facility for compact panel filters Incl. 1 set of mounting brackets (2 pce) (L x D x H) 1017 x 508 x 367mm CFL L x 712 x 367mm CFL L x 915 x 411mm CFL L x 966 x 495mm CFL L57 PKW COOLING COIL EXTENSION MODULE Can be fitted to the unit as an option With filter insert facility for compact panel filters Incl. 1 set of mounting brackets (2 pce) (L x D x H) 712 x 508 x 367mm CFL 10 / SUP ri L x 508 x 367mm CFL 10 / SUP le L x 712 x 367mm CFL 15 / SUP ri L x 712 x 367mm CFL 15 / SUP le L x 915 x 411mm CFL 22 / SUP ri L x 915 x 411mm CFL 22 / SUP le L x 966 x 495mm CFL 32 / SUP ri L x 966 x 495mm CFL 32 / SUP le L57 EXTENSION MODULE FOR DIRECT EXPANSION COIL Can be fitted to the unit as an option With filter insert facility for compact panel filters Incl. 1 set of mounting brackets (2 pce) (L x D x H) 712 x 508 x 367mm CFL 10 / SUP ri L x 508 x 367mm CFL 10 / SUP le L x 712 x 367mm CFL 15 / SUP ri L x 712 x 367mm CFL 15 / SUP le L x 915 x 411mm CFL 22 / SUP ri L x 915 x 411mm CFL 22 / SUP le L x 966 x 495mm CFL 32 / SUP ri L x 966 x 495mm CFL 32 / SUP le L57 PWW HEATING COIL EXTENSION MODULE Can be fitted to the unit as an option With supply air sensor and frost stat Incl. 1 set of mounting brackets (2 pce) (L x D x H) x 508 x 367mm CFL 10-WRG-PWW con. side SUP right 407 x 508 x 367mm CFL 10-WRG-PWW con. side SUP left 407 x 712 x 367mm CFL 15-WRG-PWW con. side SUP right 407 x 712 x 367mm CFL 15-WRG-PWW con. side SUP left 407 x 912 x 411mm CFL 22-WRG-PWW con. side SUP right 407 x 915 x 411mm CFL 22-WRG-PWW con. side SUP left 407 x 966 x 495mm CFL 32-WRG-PWW con. side SUP right 407 x 966 x 495mm CFL 32-WRG-PWW con. side SUP left L L L L L L L L WOLF ACCESSORIES

161 EXTENSION MODULE for product Art. no. DG ELECTRIC REHEATING COIL EXTENSION MODULE, VARIABLE (0-10 V) Can be fitted to the unit as an option With supply air sensor Incl. 1 set of mounting brackets (2 pce) (L x D x H) 4000W; 407 x 712 x 367mm CFL 15-WRG-E connect. side SUP right 4000W; 407 x 712 x 367mm CFL 15-WRG-E connect. side SUP left 6000W; 407 x 915 x 411mm CFL 22-WRG-E connect. side SUP right 6000W; 407 x 915 x 411mm CFL 22-WRG-E connect. side SUP left 8000W; 407 x 966 x 495mm CFL 32-WRG-E connect. side SUP right 8000W; 407 x 966 x 495mm CFL 32-WRG-E connect. side SUP left L L L L L L57 FILTER SECTION WITH INTEGRATED ATTENUA- TING FUNCTION Length 215 mm For compact panel filters M5: 409 x 247mm CFL L57... M5: 612 x 247mm CFL L57... M5: 815 x 291mm CFL L57... M5: 866 x 361mm CFL L57... F7: 409 x 247mm CFL L57... F7: 612 x 247mm CFL L57... F7: 815 x 291mm CFL L57... F7: 866 x 361mm CFL L57... F9: 409 x 247mm CFL L57... F9: 612 x 247mm CFL L57... F9: 815 x 291mm CFL L57... F9: 866 x 361mm CFL L57 HEPA FILTER SECTION WITH INTEGRATED AT- TENUATING FUNCTION, length 508mm, HEPA filter H x 250mm CFL L x 250mm CFL L x 295mm CFL L x 359mm CFL L57 MIXING/EXHAUST AIR SECTION, SHORT (MF-K) Different versions may be selected CFL 10 CFL 15 CFL 22 on request on request on request 12 24V VARIABLE SPEED SERVOMOTOR FOR LOUV- RE DAMPER Can be rotated to the left or right, incl. mounting bracket CFL-MF-K, CFL-MF-L on request WOLF ACCESSORIES

162 EXTENSION MODULE for product Art. no. DG MIXING/EXHAUST AIR SECTION, LONG (MF-L) Different versions may be selected CFL 10 CFL 15 CFL 22 on request on request on request 24V VARIABLE SPEED SERVOMOTOR FOR LOUV- RE DAMPER Can be rotated to the left or right, incl. mounting bracket CFL-MF-K, CFL-MF-L on request WOLF ACCESSORIES

163 DEVICE ACCESSORIES for product Art. no. ACCESS DOOR 2 additional access doors for easy filter inspection CFL-WRG 10, 15, 22 on request TRANSPORT DEVICE Fitted, to facilitate transportation in case of low access openings CFL 32-WRG on request M5 COMPACT PANEL FILTER Depth 48mm, fine dust filter 389 x 287mm CFL 10-WRG L x 287mm CFL 15-WRG, CKL-1300, L57 EM CRL x 333mm CFL 22-WRG L x 406mm CFL 32-WRG L57 F7 COMPACT PANEL FILTER Depth 48mm, fine dust and pollen filter 389 x 287mm CFL 10-WRG L x 287mm CFL 15-WRG, CKL-1300, L57 EM CRL x 333mm CFL 22-WRG L x 406mm CFL 32-WRG L57 F9 COMPACT PANEL FILTER Depth 48mm, fine dust and pollen filter 389 x 287mm CFL 10-WRG L x 287mm CFL 15-WRG, CKL-1300, L57 EM CRL x 333mm CFL 22-WRG L x 406mm CFL 32-WRG L57 M5 COMPACT PANEL FILTER Depth 96mm, fine dust filter 389 x 287mm CFL 10-EC-ABL L x 287mm CFL 15-EC-ABL L x 333mm CFL 22-EC-ABL L x 406mm CFL 32-EC-ABL L57 F7 COMPACT PANEL FILTER Depth 96mm, fine dust and pollen filter 389 x 287mm CFL 10-EC-ZUL L x 287mm CFL 15-EC-ZUL L x 333mm CFL 22-EC-ZUL L x 406mm CFL 32-EC-ZUL L57 F9 COMPACT PANEL FILTER Depth 96mm, fine dust and pollen filter x 287mm CFL 10-EC-ZUL L x 287mm CFL 15-EC-ZUL L x 333mm CFL 22-EC-ZUL L x 406mm CFL 32-EC-ZUL L WOLF ACCESSORIES

164 DEVICE ACCESSORIES for product Art. no. DG H13 HEPA FILTER Depth 292mm 393 x 200mm CFL L x 200mm CFL L x 250mm CFL L x 314mm CFL L57 230V SERVOMOTOR FOR OPENING/CLOSING LOUVRE DAMPER, LOOSE Incl. mounting bracket CFL L57 TRAP WITH NON-RETURN DEVICE 1¼, intake side, supplied separately (fitted as standard in CKL-iH-4400, 5800) (2 pce) CFL, CKL, CRL L57 MIXING VALVE FOR HEAT EXCHANGER, LOOSE Type depending on heat exchanger selection DN10 Kvs 0.63 DN10 Kvs 1.0 DN10 Kvs 0.63 DN15 Kvs 2.5 DN20 Kvs 4.0 DN25 Kvs 6.3 DN25 Kvs 10 CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL L L L L L L L57 THREADED FITTING KIT FOR MIXING VALVES FOR HEAT EXCHANGER Consisting of: 3 union nuts, 3 inlay nuts and 3 flat gaskets ½ DN10 Kvs 0.63 CFL, CKL, CRL L57 ½ DN10 Kvs 1.0 ½ DN10 Kvs 1.6 ¾ DN15 Kvs 2.5 CFL, CKL, CRL L57 1 DN20 Kvs 4.0 CFL, CKL, CRL L57 1¼ DN25 Kvs 6.3 CFL, CKL, CRL L57 1½ DN25 Kvs 10 CFL, CKL, CRL L57 12 MIXING VALVE DRIVE, LOOSE 24V DC, 0-10V control signal CFL-WRG, CFL-EC-ZUL, CKL, CRL L WOLF ACCESSORIES

165 COMMISSIONING Art. no. DG COMMISSIONING OF 1 STANDARD UNIT Appointment necessary (at least 8 working days before actual commissioning) Net price COMMISSIONING OF FURTHER ACCESSORIES Heating or cooling or multiple units on request WOLF ACCESSORIES

166 + WOLF UNIT Connectionseite Supply air direction left Connection side Supply air direction right ABL ETA AUL ODA AUL ODA ABL ETA ZUL SUP FOL EHA FOL EHA ZUL SUP CFL-WRG COMBINED SUPPLY AND EXTRACT AIR UNIT Type CFL 10-WRG 15-WRG 22-WRG 32-WRG Lenght mm Depth mm Hight mm ZUL SUP Connection side Supply air direction left AUL ODA Connection side Supply air direction right AUL ZUL ++ ODA SUP CFL-EC-ZUL SUPPLY AIR UNIT Type CFL 10-EC-ZUL 15-EC-ZUL 22-EC-ZUL 32-EC-ZUL Lenght mm Depth mm Hight mm Connection side Exhaust air direction left FOL EHA ABL ETA Connection side Exhaust air direction right ABL ETA FOL EHA CFL-EC-ABL EXTRACT AIR UNIT / CFL-EC-ZUL SUPPLY AIR UNIT, SHORT Type CFL 10-EC 15-EC 22-EC 32-EC Lenght mm Depth mm Hight mm WOLF TECHNICAL DATA

167 CKL COMPACT COMFORT VENTILATION UNIT COMPACT COMFORT VENTILATION UNIT 2 CKL-IV CKL-IH CKL-A Comfort compact ventilation unit for indoor installation with vertical duct connection Comfort compact ventilation unit for indoor installation with horizontal duct connection Comfort compact ventilation unit weatherproof with horizontal duct connection CONTROL ACCESSORIES 5 ACCESSORIES 7 HEATER BANKS 7 CONNECTING ACCESSORIES 8 EXTENSION MODULE 10 DEVICE ACCESSORIES 13 POSSIBLE UNIT DESIGN VERSIONS 15 CKL-A/-IH 15 TECHNICAL DATA 16 UNIT WOLF

168 CKL-IV COMFORT COMPACT VENTILATION UNIT FOR INDOOR INSTALLATION WITH VERTICAL DUCT CONNECTION RG L56 TYPE CKL-iV Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece one-piece 2 parts 2 parts Dimensions Length mm Depth (incl. lock) mm Height (incl. damper, feet) mm Weight basic unit kg SUP ri SUP le SUP ri SUP le PWW PWW Electro Electro Art. no. on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request Art. no. on request on request on request on request on request on request 13 The Comfort compact ventilation unit from WOLF offers energy saving and convenient ventilation all year round. Suitable for classrooms, conference rooms, open plan offices, restaurants, etc. High efficiency cross- and countercurrent heat exchanger made from aluminium for heat recovery. Heat is extracted from the extract air and transferred to the fresh air. With integral bypass for night ventilation in summer. Compact, inherently stable, height-adjustable casing made from powder-coated sheet steel (traffic white RAL 9016), intermediate stop rail (silver RAL 9006) High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption Integrated temperature control with programming unit: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air / icing sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal outdoor and extract air damper as standard Easily replaceable compact panel filters: F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) Stainless steel condensate pans for EHA/SUP as standard; condensate connector at the bottom CKL-iH-4400 and CKL-iH-5800 can be split width-wise and control unit pivoted for transportation purposes Incl. control unit for switching the reheating coil, as well as the cooling coil or direct expansion coil WOLF COMPACT COMFORT VENTILATION UNIT

169 CKL-IH COMFORT COMPACT VENTILATION UNIT FOR INDOOR INSTALLATION WITH HORIZONTAL DUCT CONNECTION RG L56 TYPE CKL-iH Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece one-piece 2 parts 2 parts Dimensions ength mm Depth (incl. lock) mm Height (incl. control, feet) mm Weight basic unit kg SUP ri SUP le SUP ri SUP le PWW PWW Electro Electro Art. no. on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request Art. no. on request on request on request on request on request on request The Comfort compact ventilation unit from WOLF offers energy saving and convenient ventilation all year round. Suitable for classrooms, conference rooms, open plan offices, restaurants, etc. High efficiency cross- and countercurrent heat exchanger made from aluminium for heat recovery. Heat is extracted from the extract air and transferred to the fresh air. With integral bypass for night ventilation in summer. Compact, inherently stable, height-adjustable casing made from powder-coated sheet steel (traffic white RAL 9016), intermediate stop rail (silver RAL 9006) High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption Integrated temperature control with programming unit: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air / icing sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal outdoor and extract air damper as standard Easily replaceable compact panel filters: F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) Stainless steel condensate pans for EHA/SUP as standard; condensate connector at the bottom CKL-iH-4400 and CKL-iH-5800 can be split width-wise and control unit pivoted for transportation purposes Incl. control unit for switching the reheating coil, as well as the cooling coil or direct expansion coil WOLF COMPACT COMFORT VENTILATION UNIT

170 CKL-A COMFORT COMPACT VENTILATION UNIT WEATHERPROOF WITH HORIZONTAL DUCT CONNEC- TION RG L56 TYPE CKL-A Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece one-piece one-piece one-piece Dimensions Length mm Length (incl. hoods) mm Depth (incl. roof) mm Height mm Height (without base frame, without roof) mm Weight basic unit kg SUP ri SUP le SUP ri SUP le PWW PWW Electro Electro Art. no. on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request Art. no. on request on request on request on request on request on request 13 The Comfort ventilation unit from WOLF offers energy saving and convenient ventilation all year round. High efficiency cross- and countercurrent heat exchanger made from aluminium for heat recovery. Heat is extracted from the extract air and transferred to the fresh air. With integral bypass for night ventilation in summer. Casing: Powder-coated steel sheet (traffic white RAL 9016) Intermediate stop rail, roof, intake hood, discharge hood (silver RAL 9006) Fitted as standard: Weatherproof base frame, lifting lugs, intake hood with mist eliminator and stainless steel condensate pan; discharge hood High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption BMK air handling programming unit, supplied separately Integrated temperature control: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air / icing sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal outdoor and extract air damper as standard Easily replaceable compact panel filters: F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) Stainless steel condensate pans for EHA/SUP as standard; condensate connector at the bottom Incl. control unit for switching the reheating coil, as well as the cooling coil or direct expansion coil WOLF COMPACT COMFORT VENTILATION UNIT

171 CONTROL ACCESSORIES for product Art. no. DG AIR QUALITY SENSOR Mixed gas sensor to measure the air quality; plug-in design CKL, CRL L56 CO2 SENSOR Required for CO 2 -controlled operation, plug-in design CKL, CRL L56 OUTSIDE, CEILING OR ROOM TEMPERATURE SEN- SOR LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, LHD, TL- HD-EC, TLHD-K-EC, TLHD, TLHD-K, CFL-WRG, CFL- EC-ZUL, CKL, CRL H41 DUCT HYGROSTAT, LOOSE With wall retainer CFL, CKL, CRL L57 ROOM HYGROSTAT Loose CFL, CKL, CRL L57 BMK-F REMOTE CONTROL Wall mounting CFL-WRG, CKL, CRL L56 LON INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 BACNET INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 ETHERNET INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L WOLF CKL COMPACT COMFORT VENTILATION UNIT

172 CONTROL ACCESSORIES for product Art. no. DG MODBUS INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 KNX INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL on request NEW WOLF LINK PRO - LAN / WLAN INTERFACE MODU- LE EXTERNAL Consisting of: ISM7e / WOLF Link Pro interface module, installation / operating instructions, ebus cable, power supply unit, network cable LAN and WLAN interface module for wall mounting or mobile use of Wolf heating and ventilation devices Connection of WOLF heating appliances to the WOLF Smartset portal / app Use for parameterising compatible WOLF devices Power supply via power supply unit or USB CWL Excellent, CWL-F/T-Excellent CFL, CKL, CRL H41 BMK-T10 TOUCH PANEL Option of operating multiple appliances Installation at the front on site CFL-WRG, CKL, CRL L57 FLOW RATE CONTROL CKL-1300, 2200, 3000 CRL-1300, 2500, 3500 CKL-4400, 5800, CRL-4800, 6200, L L56 CONSTANT PRESSURE CONTROL CKL-1300, 2200, 3000 CRL-1300, 2500, 3500 CKL-4400, 5800, CRL-4800, 6200, L L WOLF CKL COMPACT COMFORT VENTILATION UNIT

173 HEATER BANKS for product Art. no. DG NEW ELECTRIC PREHEATING COIL; SINGLE STAGE FOR FILTER PRE-DRYING Recommended for optimal operation of the unit 1000W; 1x230V/50Hz CKL-iV/iH/A-1300, ODA L56 horizontal air direction for CRL W; 1x230V/50Hz CKL-iH/A-1300, L56 CRL-iD/iH/A W; 1x230V/0Hz CKL-iV-2200, L W; 1x230V/50Hz CKL-iH/A-2200, 3000, L56 ODA horizontal air direction for CRL W; 2x230V/50Hz CKL-iH/A L W; 2x230V/50Hz CKL-iH/A-3000, L56 CRL-iD/iH/A W; 2x230V/50Hz CKL-iV-4400, L W; 2x230V/50Hz CKL-iH/A-4400, 5800, L56 ODA horizontal air direction for CRL-iD/iH/A/iDH W; 2x230V/50Hz CKL-iH/A-4400, L56 CRL-iD/iH/A W; 2x230V/50Hz CKL-iH/A L56 Note: Fully wired electric heating coil with high limit safety cut-out, frost stat and bracket to protect the outdoor air filter against moisture penetration or as frost protection for the heat recovery system ELECTRIC REHEATING COIL For increasing the supply air temperature at low outside temperatures; can be integrated into the unit as an option; electrical plug-in design 1000W; 1x230V/50Hz CKL-iH-1300, CRL L W; 1x230V/50Hz CKL-iV/A L W; 3x400V/50Hz CKL-iV L W; 3x400V/50Hz CKL-iH/A L W; 3x400V/50Hz CKL-iV L W; 3x400V/50Hz CKL-iH/A L56 PWW HEAT EXCHANGER (PUMPED HOT WATER) Copper/aluminium heat exchanger with frost stat, fully wired CKL-iV L56 CKL-iH/A-1300, CRL L CKL-iV L56 CKL-iH/A L56 CKL-iV L56 CKL-iH/A-3000, CRL L CKL-A L56 CKL-iV L56 CKL-iV L56 CKL-A L56 Note: Extension module (EKTA section) required for CKL-iH-4400, WOLF ACCESSORIES

174 CONNECTING ACCESSORIES for product Art. no. DG INSULATING FRAME 596 x 205mm (4 pce) CKL-iV L x 307mm (4 pce) CKL-iV L x 307mm (4 pce) CKL-iV L x 358mm (4 pce) CKL-iV L x 358mm (4 pce) CKL-iV L x 409mm (2 pce) CKL-A-1300, L56 CRL-A x 612mm (2 pce) CKL-A L x 612mm (2 pce) CKL-A-3000, L56 CRL-A x 612mm (2 pce) CKL-A-4400, L56 CRL-A x 612mm (2 pce) CKL-A-5800, L56 CRL-A x 409mm (4 pce) CKL-iH-1300, L56 CRL-iH x 612mm (4 pce) CKL-iH L x 612mm (4 pce) CKL-iH-3000, L56 CRL-iH x 612mm (4 pce) CKL-iH-4400, L56 CRL-iH x 612mm (4 pce) CKL-iH-5800, CRL-iD/iDH L56 FLEXIBLE CONNECTION 592 x 201mm (4 pce) CKL-iV L x 303mm (4 pce) CKL-iV L x 303mm (4 pce) CKL-iV L x 354mm (4 pce) CKL-iV L x 354mm (4 pce) CKL-iV L x 405mm (2 pce) CKL-A-1300, L56 CRL-A x 608mm (2 pce) CKL-A L x 608mm (2 pce) CKL-A-3000, L56 CRL-A x 608mm (2 pce) CKL-A-4400, L56 CRL-A x 608mm (2 pce) CKL-A-5800, L56 CRL-A x 405mm (4 pce) CKL-iH-1300, L56 CRL-iH x 608mm (4 pce) CKL-iH L x 608mm (4 pce) CKL-iH-3000, L56 CRL-iH x 608mm (4 pce) CKL-iH-4400, L56 CRL-iH x 608mm (4 pce) CKL-iH-5800, CRL-iD/iH/iDH L56 Optional: Flexible connection in thermally insulated version, Insulation sickness 10mm ADAPTOR BOX FROM RECTANGULAR TO ROUND CONNECTION FOR VERTICAL DIRECTION OF AIR- FLOW (Set = 2 pce) 13 Diameter 315mm CKL-iV L56 Diameter 400mm CKL-iV L56 Diameter 450mm CKL-iV L56 Diameter 560mm CKL-iV L56 (insulating frame required) Diameter 560mm (insulating frame required) CKL-iV L WOLF ACCESSORIES

175 CONNECTING ACCESSORIES for product Art. no. DG INSULATING ADAPTOR CONE FROM RECTANGU- LAR TO ROUND CONNECTION Diameter 315mm (2 pce) CKL-A-1300, L56 CRL-A-1300 Diameter 400mm (2 pce) CKL-A L56 Diameter 450mm (2 pce) CKL-A-3000, L56 CRL-A-2500 Diameter 560mm (2 pce) CKL-A-4400, L56 CRL-A-4800 Diameter 560mm (2 pce) CKL-A-5800, L56 CRL-A-6200 Diameter 315mm (4 pce) CKL-iH L56 Diameter 400mm (4 pce) CKL-iH L56 Diameter 450mm (4 pce) CKL-iH-3000, L56 CRL-iH-2500 Diameter 560mm (4 pce) CKL-iH-4400, L56 CRL-iH-4800 Diameter 560mm (4 pce) CKL-iH-5800, CRL-iD/iH/iDH L WOLF ACCESSORIES

176 EXTENSION MODULE for product Art. no. DG NEW OUTDOOR AIR SILENCER MODULE Horizontal air routing Incl. pan and F7 outdoor air filter (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL-iD/iH/iDH x 750 x 712mm CKL-iH/A-2200 on request 1017 x 955 x 712mm CKL-iH/A-3000, on request CRL-iD/iH/iDH x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, CRL-6200 on request EXTRACT AIR SILENCER MODULE Horizontal air routing Incl. M5 extract air filter (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 750 x 712mm CKL-iH/A-2200 on request 1017 x 955 x 712mm CKL-iH/A-3000, on request CRL x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, CRL-6200 on request SUPPLY AIR/EXHAUST AIR SILENCER MODULE For horizontal air routing (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 750 x 712mm CKL-iH/A-2200 on request 1017 x 955 x 712mm CKL-iH/A-3000, on request CRL x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, CRL-6200 on request HEATING COIL - COOLING COIL - DE SECTION (HCCCDE) horizontal air flow for supply air bottom (L x T x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 750 x 712mm CKL-iH/A-2200 on request 1017 x 955 x 712mm CKL-iH/A-3000, on request CRL x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, CRL-6200 on request WOLF ACCESSORIES

177 EXTENSION MODULE for product Art. no. DG HEAT PUMP EKTA MODULE (WP-EKTA) Horizontal ventilation for supply air version at the bottom Consisting of direct expansion coil/condenser coil, inverter-controlled heat pump outdoor unit and control kit integrated in the module (L x D x H) 1017x 750 x 508mm CKL-1300, CRL-1300 on request 1017 x 750 x 712mm CKL-2200 on request 1017 x 955 x 712mm CKL-3000, CRL-2500 on request 1017 x 1360 x 712mm CKL-4800, CRL-4800 on request 1017 x 1665 x 712mm CKL-5800, CRL-6200 on request EMPTY SECTION For horizontal air routing (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 750 x 712mm CKL-iH/A-2200 on request 1017 x 955 x 712mm CKL-iH/A-3000, on request CRL x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, CRL-6200 on request EMPTY SECTION For downward air routing Internal damper, insulating frame and flexible connection are available as options (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 750 x 712mm CKL-iH/A-2200 on request 1017 x 955 x 712mm CKL-iH/A-3000, on request CRL x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, CRL-6200 on request COOLING COIL SECTION For horizontal air routing (L x D x H) 611 x 750 x 508mm CKL-iH-1300, CRL-iD/iH/ on request idh x 750 x 712mm CKL-iH-2200 on request 611 x 955 x 712mm CKL-iH-3000, CRL-iD/iH/ on request idh x 1360 x 712mm CKL-iH-4400, CRL-iD/iH/ on request idh x 1665 x 712mm CKL-iH-5800, CRL-iD/iH/ idh-6200 on request WOLF ACCESSORIES

178 EXTENSION MODULE for product Art. no. DG DIRECT EXPANSION COIL MODULE For horizontal air routing (L x D x H) 611 x 750 x 508mm CKL-iH-1300, on request CRL-iD/iH/iDH x 750 x 712mm CKL-iH-2200 on request 611 x 955 x 712mm CKL-iH-3000, on request CRL-iD/iH/iDH x 1360 x 712mm CKL-iH-4400, on request CRL-iD/iH/iDH x 1665 x 712mm CKL-iH-5800, CRL-iD/iH/iDH-6200 on request HEATING COIL MODULE For horizontal air routing (L x D x H) 305 x 750 x 508mm CKL-iH-1300 on request 305 x 750 x 712mm CKL-iH-2200 on request 305 x 955 x 712mm CKL-iH-3000 on request 305 x 1360 x 712mm CKL-iH-4400, on request CRL-iD/iH/iDH x 1665 x 712mm CKL-iH-5800, CRL-iD/iH/iDH-6200 on request WOLF ACCESSORIES

179 DEVICE ACCESSORIES for product Art. no. DG PIPEWORK SILENCER, LENGTH 600 MM All-round insulation 90mm Diameter 315mm (attenuation 8dB / 250Hz) CKL-1300, CRL L56 Diameter 400mm (attenuation 6dB / 250Hz) CKL L56 Diameter 450mm (attenuation 6dB / 250Hz) CKL-3000, CRL L56 Diameter 560mm (attenuation 5dB / 250Hz) CKL-4400/5800, CRL-4800/ L56 M5 COMPACT PANEL FILTER Depth 48mm, fine dust filter 592 x 287mm CFL 15-WRG, CKL-1300, L57 EM CRL x 592mm CKL L x 404mm (2 pce) CKL-3000, CRL L x 592mm (2 pce) CKL-4400, CRL L x 592mm (2 pce) 592 x 287mm (1 pce) CKL-5800, CRL L56 F7 COMPACT PANEL FILTER Depth 48mm, fine dust and pollen filter 592 x 287mm CFL 15-WRG, CKL-1300, L57 EM CRL x 592mm CKL L x 404mm (2 pce) CKL-3000, CRL L x 592mm (2 pce) CKL-4400, CRL L x 592mm (2 pce) 592 x 287mm (1 pce) CKL-5800, CRL L56 F9 COMPACT PANEL FILTER Depth 48mm, fine dust and pollen filter 592 x 287mm CFL 15-WRG, CKL-1300, L57 EM CRL x 592mm CKL L x 404mm (2 pce) CKL-3000, CRL L x 592mm (2 pce) CKL-4400, CRL L x 592mm (2 pce) 592 x 287mm (1 pce) CKL-5800, CRL L56 TRAP WITH NON-RETURN DEVICE 1¼, intake side, supplied separately (fitted as standard in CKL-iH-4400, 5800) (2 pce) CFL, CKL, CRL L56 TRAP WITH NON-RETURN DEVICE 1¼, intake and pressure sides, supplied separately, for modules with condensate drain CFL, CKL, CRL L57 FROST PROTECTION HEATER For trap CKL-A, CRL-A L WOLF ACCESSORIES

180 DEVICE ACCESSORIES for product Art. no. DG MIXING VALVE FOR HEAT EXCHANGER, LOOSE Type depending on heat exchanger selection DN10 Kvs 0.63 DN10 Kvs 1.0 DN10 Kvs 0.63 DN15 Kvs 2.5 DN20 Kvs 4.0 DN25 Kvs 6.3 DN25 Kvs 10 CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL CFL-WRG, CFL-EC-ZUL, CKL, CRL L L L L L L L57 THREADED FITTING KIT FOR MIXING VALVES FOR HEAT EXCHANGER Consisting of: 3 union nuts, 3 inlay nuts and 3 flat gaskets ½ DN10 Kvs 0.63 CFL, CKL, CRL L57 ½ DN10 Kvs 1.0 ½ DN10 Kvs 1.6 ¾ DN15 Kvs 2.5 CFL, CKL, CRL L57 1 DN20 Kvs 4.0 CFL, CKL, CRL L57 1¼ DN25 Kvs 6.3 CFL, CKL, CRL L57 1½ DN25 Kvs 10 CFL, CKL, CRL L57 MIXING VALVE DRIVE, LOOSE 24V DC, 0-10V control signal CFL-WRG, CFL-EC-ZUL, CKL, CRL L57 COMMISSIONING OF 1 STANDARD UNIT Appointment necessary (at least 8 working days before actual commissioning) Net price COMMISSIONING OF FURTHER ACCESSORIES Heating or cooling or multiple units on request WOLF ACCESSORIES

181 CKL-A/-IH CKL-A/-IH With optional horizontal / vertical duct connection depending on appliance version and installation position. Depending on different thermodynamical (heating, cooling) and acoustical (sound) requirements, our self-developped design program offers the opportunity of an individual configuration (technical data, delivery time and price on request). Example: Maximum view of possible unit design versions A F B E C D Legend: A outdoor air (ODA) B extract air (ETA) alternative intake C extract air (ETA) alternative intake D supply air (SUP) alternative discharge without fitted parts (only empty section) E supply air (SUP) alternative discharge with / without fitted part(s) F exhaust air (EHA) 1 intake hood with mist eliminator 2 outdoor air silencer section 3 F7 filter outdoor air 4 bypass damper 5 weatherproof roof 6 repair switch 7 control panel 8 EC fan extract air 9 exhaust air silencer section 10 discharge hood 11 empty section 12 F5 filter extract air 13 base frame 14 countercurrent heat exchanger with bypass 15 condensate pan 16 EC fan supply air 17 heating coil 18 cooling coil 19 mist eliminator Hinweis nur für CKL-A: Extract air intake and supply air discharge can be arranged as required, horizontally or vertically. Please note that a horizontal arrangement of the supply air discharge is only possible when fitted parts such as the heating coil, cooling coil or mist eliminator are installed downstream of the supply air fan. To direct the supply air discharge downwards despite fitted parts, an additional empty section can be added, for example WOLF POSSIBLE UNIT DESIGN VERSIONS

182 UNIT Connection side Supply air direction left ZUL SUP ABL ETA AUL ODA FOL EHA Connection side Supply air direction right FOL EHA AUL ODA ABL ETA ZUL SUP CKL-IV COMBINED SUPPLY AND EXTRACT AIR UNIT Type CKL-iV Length mm Depth mm Height mm Connection side Supply air direction left Connection side Supply air direction right ABL ETA AUL ODA AUL ODA ABL ETA ZUL SUP FOL EHA FOL EHA ZUL SUP CKL-IH COMBINED SUPPLY AND EXTRACT AIR UNIT Type CKL-iH Length mm Depth mm Height mm FOL EHA Connection side Supply air direction left AUL ODA AUL ODA Connection side Supply air direction right FOL EHA ZUL SUP ABL ETA ABL ETA ZUL SUP CKL-A COMBINED SUPPLY AND EXTRACT AIR UNIT Type CKL-A Length mm Depth mm Height mm WOLF TECHNICAL DATA

183 COMFORT SWIMMING POOL UNIT COMFORT SWIMMING POOL UNIT 2 CKL-POOL Comfort swimming pool unit for ventilation and thermal conditioning of small enclosed swimming pools ACCESSORIES 3 ACCESSORIES 3 TECHNICAL DATA 4 UNIT WOLF

184 CKL-POOL COMFORT SWIMMING POOL UNIT FOR VENTILATION AND THERMAL CONDITIONING OF SMALL ENCLOSED SWIMMING POOLS RG TYPE CKL-Pool 20 GC 30 GC Max. air volume m³/h with externally available pressure of approx. Pa Water surface pool m² Dimensions Length mm Depth mm Height (with base frame) mm Weight kg SUP ri SUP le Art. no. on request on request on request on request Art. no. on request on request on request on request Removes damp air from swimming pools to prevent unpleasant air conditions which can have a negative impact on both people and the building Designed on the basis of VDI 2089 Combined extractor and supply air unit with plate heat exchanger made from corrosion-resistant polypropylene, integrated heat pump as standard Variable speed free-running EC fans with low energy consumption Compact panel filter F7 in the outdoor air, M5 in the extract air Integrated control panel, unit fully wired and ready to connect Housing with good thermal properties (T2/B2 according to DIN EN 1886), internal and external coating for optimised corrosion resistance, colour RAL 9016 (traffic white) Fitted base frame (100mm) Accessories included as standard 2 x siphon 1¼ inch, 10 x elastomer strip for setting up the unit, control valve and drive for PWW heating coil Integrated PWW heating coil included as standard WOLF COMFORT SWIMMING POOL UNIT

185 ACCESSORIES for product Art. no. DG REMOTE CONTROL For wall mounting with integral room temperature sensor BACNET INTERFACE BACNET IP-INTERFACE LON-INTERFACE WEB-MODUL POOL WATER CONDENSER Stainless steel design, for heating the pool water CKL-Pool 20 GC CKL-Pool 30 GC COMMISSIONING OF CKL-POOL Appointment necessary (at least 8 working days before actual commissioning) Net price WOLF ACCESSORIES

186 UNIT Connection side left Connection side right COMFORT SWIMMING POOL UNIT CKL-POOL Type CKL-Pool 20 GC 30 GC a mm b mm c mm d mm e G 1¼ 1¼ f mm g mm WOLF TECHNICAL DATA

187 CRL COMFORT ROTARY HEAT EXCHANGER VEN- TILATION UNIT COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT 2 CRL-ID CRL-IH CRL-IDH CRL-A Comfort thermal wheel heat exchanger ventilation unit for indoor installation with vertical/horizontal duct connection Comfort thermal wheel heat exchanger ventilation unit for indoor installation with horizontal duct connection Comfort thermal wheel heat exchanger ventilation unit for indoor installation with horizontal/vertical/horizontal duct connection Comfort thermal wheel heat exchanger ventilation unit for outdoor installation with horizontal duct connection CONTROL ACCESSORIES 6 ACCESSORIES 8 HEATER BANKS 8 CONNECTING ACCESSORIES 10 EXTENSION MODULE (EM) 12 DEVICE ACCESSORIES 15 COMMISSIONING 17 POSSIBLE UNIT DESIGN VERSIONS 18 CRL-ID 18 CRL-IH 20 CRL-IDH 22 CRL-A WOLF 15

188 CRL-ID COMFORT THERMAL WHEEL HEAT EXCHANGER VEN- TILATION UNIT FOR INDOOR INSTALLATION WITH VERTICAL/HORI- ZONTAL DUCT CONNECTION NEW RG L56 TYPE CRL-iD Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece 3 parts 3 parts 3 parts 3 parts Dimensions Length mm Length with damper for quick heating mm Width (incl. lock) mm Height (incl. control, feet) mm Weight Basic unit kg Basic unit with damper for quick heating kg Condensation rotor 2. Enthalpy rotor 3. Sorption rotor Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Comfort thermal wheel heat exchanger ventilation unit for energy saving and convenient ventilation. High performance thermal wheel heat exchanger made from aluminium with heat recovery rates of up to 90% and humidity recovery rates of over 90% Casing: Powder-coated sheet steel (traffic white RAL 9016), thermal wheel heat exchanger access door (silver RAL 9006) Operating side either on the right or left in supply air direction Compact, inherently stable, height-adjustable casing High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption High performance thermal wheel heat exchanger with new WOLF sealing system with leakage rates below 2%, either with condensation rotor, enthalpy rotor or sorption rotor Temperature control via integral programming unit: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal and external outdoor and extract air damper as standard Easily replaceable compact panel filters: F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) Compact three-piece casing design, optimised for ease of handling 15 Control unit for switching electric preheating coils, PWW reheating coils, PKW cooling coils or direct expansion coils WOLF COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT

189 CRL-IH COMFORT THERMAL WHEEL HEAT EXCHANGER VEN- TILATION UNIT FOR INDOOR INSTALLATION WITH HORIZONTAL DUCT CONNECTION NEW RG L56 TYPE CRL-iH Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece 3 parts 3 parts 3 parts 3 parts Dimensions Length mm Length with damper for quick heating mm Width (incl. lock) mm Height incl. control, feet mm Weight Basic unit kg Basic unit with damper for quick heating kg Condensation rotor 2. Enthalpy rotor 3. Sorption rotor Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Comfort thermal wheel heat exchanger ventilation unit for energy saving and convenient ventilation. High performance thermal wheel heat exchanger made from aluminium with heat recovery rates of up to 90% and humidity recovery rates of over 90% Casing: Powder-coated sheet steel (traffic white RAL 9016), thermal wheel heat exchanger access door (silver RAL 9006) Operating side either on the right or left in supply air direction Compact, inherently stable, height-adjustable casing High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption High performance thermal wheel heat exchanger with new WOLF sealing system with leakage rates below 2%, either with condensation rotor, enthalpy rotor or sorption rotor Temperature control via integral programming unit: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal and external outdoor and extract air damper as standard Easily replaceable compact panel filters: F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) Compact three-piece casing design, optimised for ease of handling Control unit for switching electric preheating coils, PWW reheating coils, PKW cooling coils or direct expansion coils WOLF COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT 15

190 CRL-IDH COMFORT THERMAL WHEEL HEAT EXCHANGER VEN- TILATION UNIT FOR INDOOR INSTALLATION WITH HORIZONTAL/VER- TICAL/HORIZONTAL DUCT CONNECTION NEW RG L56 TYPE CRL-iDH Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece 3 parts 3 parts 3 parts 3 parts Dimensions Length mm Length with damper for quick heating mm Width (incl. lock) mm Height incl. control, feet mm Weight Basic unit kg Basic unit with damper for quick heating kg Condensation rotor 2. Enthalpy rotor 3. Sorption rotor Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Comfort thermal wheel heat exchanger ventilation unit for energy saving and convenient ventilation. High performance thermal wheel heat exchanger made from aluminium with heat recovery rates of up to 90% and humidity recovery rates of over 90% Casing: Powder-coated sheet steel (traffic white RAL 9016), thermal wheel heat exchanger access door (silver RAL 9006) Operating side either on the right or left in supply air direction Compact, inherently stable, height-adjustable casing High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption High performance thermal wheel heat exchanger with new WOLF sealing system with leakage rates below 2%, either with condensation rotor, enthalpy rotor or sorption rotor Temperature control via integral programming unit: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal and external outdoor and extract air damper as standard Easily replaceable compact panel filters: F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) Compact three-piece casing design, optimised for ease of handling 15 Control unit for switching electric preheating coils, PWW reheating coils, PKW cooling coils or direct expansion coils WOLF COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT

191 CRL-A COMFORT THERMAL WHEEL HEAT EXCHANGER VEN- TILATION UNIT FOR OUTDOOR INSTALLATION WITH HORIZONTAL DUCT CONNECTION NEW TYPE CRL-A RG L56 Max. air volume m³/h with externally available pressure of approx. Pa Unit components one-piece one-piece one-piece one-piece one-piece one-piece Dimensions Length mm Length with damper for quick heating mm Depth incl. roof projection mm Height incl. control, base frame mm Weight Basic unit kg Basic unit with damper for quick heating kg Condensation rotor 2. Enthalpy rotor 3. Sorption rotor Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Art. no. on request on request on request on request on request on request on request on request on request on request on request on request Comfort thermal wheel heat exchanger ventilation unit for energy saving and convenient ventilation. High performance thermal wheel heat exchanger made from aluminium with heat recovery rates of up to 90 % and humidity recovery rates of over 90 % Casing: Powder-coated sheet steel (traffic white RAL 9016), thermal wheel heat exchanger access door (silver RAL 9006) Operating side either on the right or left in supply air direction Compact inherently stable casing Fitted as standard: Weatherproof base frame, lifting lugs High efficiency, high performance radial fans with single sided intake for supply and extract air, variable speed control via latest EC motor technology with low energy consumption High performance thermal wheel heat exchanger with new WOLF sealing system with leakage rates below 2 %, either with condensation rotor, enthalpy rotor or sorption rotor BMK air handling programming unit, supplied separately Control unit for switching electric preheating coils, PWW reheating coils, PKW cooling coils or direct expansion coils Temperature control via programming unit: Supply air temperature control (supply air sensor integrated) factory setting Extract air temperature control (extract air temperature sensor integrated) adjustable on the programming unit Room temperature control (see accessories for room temperature sensor) adjustable on the programming unit Supply air / extract air / outdoor air sensors integrated Filter pressure monitor as standard for outdoor and extract air filters Internal outdoor and extract air damper as standard Easily replaceable compact panel filters F7 outdoor air filter (fine dust and pollen filter) M5 extract air filter (fine dust filter) WOLF COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT 15

192 CONTROL ACCESSORIES for product Art. no. DG AIR QUALITY SENSOR Mixed gas sensor to measure the air quality; plug-in design CKL, CRL L56 CO2 SENSOR Required for CO 2 -controlled operation, plug-in design CKL, CRL L56 OUTSIDE, CEILING OR ROOM TEMPERATURE SEN- SOR LH-EC, LH, TLH-EC, TLH, TLHK-EC, TLHK, LHD, TL- HD-EC, TLHD-K-EC, TLHD, TLHD-K, CFL-WRG, CFL- EC-ZUL, CKL, CRL H41 DUCT HYGROSTAT, LOOSE With wall retainer CFL, CKL, CRL L57 ROOM HYGROSTAT Loose CFL, CKL, CRL L57 BMK-F REMOTE CONTROL Wall mounting CFL-WRG, CKL, CRL L56 LON INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 BACNET INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 ETHERNET INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L WOLF CRL COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT

193 CONTROL ACCESSORIES for product Art. no. DG MODBUS INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL L57 KNX INTERFACE FOR WRS-K To be plugged into the controller CFL-WRG, CKL, CRL on request NEW WOLF LINK PRO - LAN / WLAN INTERFACE MODU- LE EXTERNAL Consisting of: ISM7e / WOLF Link Pro interface module, installation / operating instructions, ebus cable, power supply unit, network cable LAN and WLAN interface module for wall mounting or mobile use of Wolf heating and ventilation devices Connection of WOLF heating appliances to the WOLF Smartset portal / app Use for parameterising compatible WOLF devices Power supply via power supply unit or USB CWL Excellent, CWL-F/T-Excellent CFL, CKL, CRL H41 BMK-T10 TOUCH PANEL Option of operating multiple appliances Installation at the front on site CFL-WRG, CKL, CRL L57 FLOW RATE CONTROL CKL-1300, 2200, 3000 CRL-1300, 2500, 3500 CKL-4400, 5800, CRL-4800, 6200, L L56 CONSTANT PRESSURE CONTROL CKL-1300, 2200, 3000 CRL-1300, 2500, 3500 CKL-4400, 5800, CRL-4800, 6200, L L WOLF CRL COMFORT ROTARY HEAT EXCHANGER VENTILATION UNIT 15

194 HEATER BANKS for product Art. no. DG NEW ELECTRIC PREHEATING COIL; SINGLE STAGE FOR FILTER PRE-DRYING Recommended for optimal operation of the unit 1000W; 1x230V/50 Hz CKL-iV/iH/A-1300, ODA horizontal air direction for CRL W; 1x230V/50Hz AUL vertikal für CRL W; 1x230V/50Hz CKL-iH/A-1300, CRL-iD/iH/A W; 1x230V/50 Hz CKL-iH/A-2200, 3000, ODA horizontal air direction for CRL W; 2x230V/50Hz AUL vertikal für CRL W; 2x230V/50Hz CKL-iH/A-3000, CRL-iD/iH/A W; 2x230V/50Hz ODA horizontal air direction for CRL W; 2x230V/50Hz ODA vertical air direction for CRL-iD/iDH W; 2x230V/50Hz AUL Luftführung horizontal SD-Teil CRL W; 2x230V/50Hz ODA vertical air direction for CRL-iD/iDH W; 2x230V/50Hz CKL-iH/A-4400, 5800, ODA horizontal air direction for CRL-iD/iH/A/iDH W; 2x230V/50Hz CKL-iH/A-4400, CRL-iD/iH/A W; 3x400V/50Hz ODA vertical air direction for CRL-iD/iDH W; 3x400V/50Hz ODA horizontal air direction for CRL-iD/iH/A/iDH W; 3x400V/50Hz ODA horizontal air direction für SD-Teil CRL-iD/ ih/a 8000W; 3x400V/50Hz ODA vertical air direction for CRL-iD/iDH W; 3x400V/50Hz ODA horizontal air direction for CRL-iD/iH/A/iDH W; 3x400V/50Hz ODA horizontal air direction für SD-Teil CRL-iD/ ih/a L L L L L L L L L L L L L L L L L L56 Note: Fully wired electric heating coil with high limit safety cut-out, frost stat and bracket to protect the outdoor air filter against moisture penetration or as frost protection for the heat recovery system ELECTRIC REHEATING COIL For increasing the supply air temperature at low outside temperatures; can be integrated into the unit as an option; electrical plug-in design 1000 W; 1x230V/50Hz CKL-iH-1300, CRL L W; 3x400V/50Hz CRL L W; 3x400V/50Hz horizontal air direction L56 for CRL W; 3x400V/50Hz vertical air direction for CRL-iD/iDH L WOLF ACCESSORIES

195 HEATER BANKS for product Art. no. DG PWW HEAT EXCHANGER (PUMPED HOT WATER) Horizontal air routing Copper/aluminium heat exchanger with frost stat, wired, CKL-iH/A-1300, CRL L CKL-iH/A-3000, CRL L CRL L56 CRL L56 CRL L56 CRL L WOLF ACCESSORIES 15

196 CONNECTING ACCESSORIES for product Art. no. DG INSULATING FRAME 596 x 307mm (2 pce), 612 x 409mm (2 pce) CRL-iD L x 409mm (4 pce) CKL-iH-1300, L56 CRL-iH x 307mm (1 pce), 612 x 409mm (3 pce) CRL-iDH L x 409mm (2 pce) CKL-A-1300, L56 CRL-A x 307mm (2 pce), 815 x 612mm (2 pce) CRL-iD L x 612mm (4 pce) CKL-iH-3000, L56 CRL-iH x 307mm (1 pce), 815 x 612mm (3 pce) CRL-iDH L x 612mm (2 pce) CKL-A-3000, L56 CRL-A x 409mm (2 pce), 1019 x 612mm (2 pce) CRL-iD L x 612mm (4 pce) CRL-iH L x 612mm (2 pce) CRL-A L x 409mm (1 pce), 1019 x 612mm (3 pce) CRL-iDH L x 510mm (2 pce), 1222 x 612mm (2 pce) CRL-iD L x 612mm (4 pce) CKL-iH-4400, L56 CRL-iH x 612mm (2 pce) CKL-A-4400, L56 CRL-A x 510mm (1 pce), 1222 x 612mm (3 pce) CRL-iDH L x 612mm (4 pce) CKL-iH-5800, L56 CRL-iD/iDH x 612mm (2 pce) CKL-A-5800, L56 CRL-A x 714mm (4 pce) CRL-iD-9000, L56 CRL-iH/iDH x 714mm (2 pce) CRL-A L56 FLEXIBLE CONNECTION 592 x 303mm (2 pce), 608 x 405mm (2 pce) CRL-iD L x 405 mm (4 pce) CKL-iH-1300, L56 CRL-iH x 303mm (1 pce), 608 x 405mm (3 pce) CRL-iDH L x 405 mm (2 pce) CKL-A-1300, L56 CRL-A x 303mm (2 pce), 811 x 608mm (2 pce) CRL-iD L x 608 mm (4 pce) CKL-iH-3000, L56 CRL-iH x 303mm (1 pce), 811 x 608mm (3 pce) CRL-iDH L x 608 mm (2 pce) CKL-A-3000, L56 CRL-A x 405 mm (2 pce), 1015 x 608 mm (2 pce) CRL-iD L x 608 mm (4 pce) CRL-iH L x 608 mm (2 pce) CRL-A L x 405 mm (1 pce), 1015 x 608 mm (3 pce) CRL-iDH L x 506 mm (2 pce), 1218 x 608 mm (2 pce) CRL-iD L x 608 mm (4 pce) CKL-iH-4400, L56 CRL-iH x 608 mm (2 pce) CKL-A-4400, L56 CRL-A x 506 mm (1 pce), 1218 x 608 mm (3 pce) CRL-iDH L x 608 mm (4 pce) CKL-iH-5800, L56 CRL-iD/iH/iDH x 608 mm (2 pce) CKL-A-5800, L56 CRL-A x 710 mm (4 pce) CRL-iD-9000, L56 CRL-iH/CRL-iDH x 710 mm (2 pce) CRL-A L56 Optional: Flexible connection in thermally insulated version, Insulation sickness 10mm WOLF ACCESSORIES

197 CONNECTING ACCESSORIES for product Art. no. DG INSULATING ADAPTOR CONE FROM RECTANGU- LAR TO ROUND CONNECTION Diameter 315mm (4 pce) CRL-iD L56 Diameter 315mm (4 pce) CKL-iH L56 Diameter 315mm (2 pce) CKL-A-1300, L56 CRL-A-1300 Diameter 315mm (4 pce) CRL-iDH L56 Diameter 450mm (4 pce) CRL-iD L56 Diameter 450mm (4 pce) CKL-iH-3000, L56 CRL-iH-2500 Diameter 450mm (4 pce) CRL-iDH L56 Diameter 450mm (2 pce) CKL-A-3000, L56 CRL-A-2500 Diameter 500mm (4 pce) CRL-iD L56 Diameter 500mm (4 pce) CRL-iH L56 Diameter 500mm (2 pce) CRL-A L56 Diameter 500mm (4 pce) CRL-iDH L56 Diameter 560mm (4 pce) CRL-iD L56 Diameter 560mm (4 pce) CKL-iH-4400, L56 CRL-iH-4800 Diameter 560mm (2 pce) CKL-A-4400, L56 CRL-A-4800 Diameter 560mm (4 pce) CRL-iDH L56 Diameter 560mm (4 pce) CKL-iH-5800, L56 CRL-iD/iH/iDH-6200 Diameter 560mm (2 pce) CKL-A-5800, CRL-A L WOLF ACCESSORIES 15

198 EXTENSION MODULE (EM) for product Art. no. DG OUTDOOR AIR SILENCER MODULE Horizontal air routing Incl. pan and F7 outdoor air filter (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL-iD/iH/iDH x 955 x 712mm CKL-iH/A-3000, on request CRL-iD/iH/iDH x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, on request CRL x 2070 x 814mm CRL-9000 on request OUTDOOR AIR SILENCER MODULE, LONG Horizontal air routing Incl. pan and F7 outdoor air filter (L x D x H) 2034 x 750 x 508mm CRL-A-1300 on request 2034 x 955 x 712mm CRL-A-2500 on request 2034 x 1155 x 712mm CRL-A-3500 on request 2034 x 1360 x 712mm CRL-A-4800 on request 2034 x 1665 x 712mm CRL-A-6200 on request 2034 x 2070 x 814mm CRL-A-9000 on request EXTRACT AIR SILENCER MODULE Horizontal air routing Incl. M5 extract air filter (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 955 x 712mm CKL-iH/A-3000, on request CRL x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, on request CRL x 2070 x 814mm CRL-9000 on request SUPPLY AIR/EXHAUST AIR SILENCER MODULE For horizontal air routing (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 955 x 712mm CKL-iH/A-3000, on request CRL x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, on request CRL x 2070 x 814mm CRL-9000 on request WOLF ACCESSORIES

199 EXTENSION MODULE (EM) for product Art. no. DG HEATING COIL - COOLING COIL - DE SECTION (HCCCDE) horizontal air flow for supply air bottom (L x T x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 955 x 712mm CKL-iH/A-3000, on request CRL x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, on request CRL x 2070 x 814mm CRL-9000 on request HEAT PUMP EKTA MODULE (WP-EKTA) Horizontal ventilation for supply air version at the bottom Consisting of direct expansion coil/condenser coil, inverter-controlled heat pump outdoor unit and control kit integrated in the module (L x T x H) 1017x 750 x 508mm CKL-1300, CRL-1300 on request 1017 x 955 x 712mm CKL-3000, CRL-2500 on request 1017 x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712mm CKL-4800, CRL-4800 on request 1017 x 1665 x 712mm CKL-5800, CRL-6200 on request 1017 x 2070 x 814 mm CRL-9000 on request EMPTY SECTION For horizontal air routing (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 955 x 712mm CKL-iH/A-3000, on request CRL x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, on request CRL x 2070 x 814mm CRL-9000 on request 1322 x 2070 x 814mm CRL-9000 on request EMPTY SECTION, LONG For horizontal air routing (L x D x H) 2034 x 750 x 508mm CRL-A-1300 on request 2034 x 955 x 712mm CRL-A-2500 on request 2034 x 1155 x 712mm CRL-A-3500 on request 2034 x 1360 x 712mm CRL-A-4800 on request 2034 x 1665 x 712mm CRL-A-6200 on request 2034 x 2070 x 814mm CRL-9000 on request WOLF ACCESSORIES 15

200 EXTENSION MODULE (EM) for product Art. no. DG EMPTY SECTION For downward air routing Internal damper, insulating frame and flexible connection are available as options (L x D x H) 1017 x 750 x 508mm CKL-iH/A-1300, on request CRL x 955 x 712mm CKL-iH/A-3000, on request CRL x 1155 x 712mm CRL-3500 on request 1017 x 1360 x 712 mm CKL-iH/A-4400, on request CRL x 1665 x 712mm CKL-iH/A-5800, on request CRL x 2070 x 814mm CRL-9000 on request 1322 x 2070 x 814mm CRL-9000 on request COOLING COIL SECTION For horizontal air routing (L x D x H) 611 x 750 x 508mm CKL-iH-1300, CRL-iD/iH/ on request idh x 955 x 712mm CKL-iH-3000, CRL-iD/iH/ on request idh x 1155 x 712mm CRL-3500 on request 611 x 1360 x 712mm CKL-iH-4400, CRL-iD/iH/ on request idh x 1665 x 712mm CKL-iH-5800, CRL-iD/iH/ on request idh x 2070 x 814mm CRL-iD/iH/iDH-9000 on request DIRECT EXPANSION COIL MODULE For horizontal air routing (L x D x H) 611 x 750 x 508mm CKL-iH-1300, on request CRL-iD/iH/iDH x 955 x 712mm CKL-iH-3000, on request CRL-iD/iH/iDH x 1155 x 712mm CRL-3500 on request 611 x 1360 x 712mm CKL-iH-4400, on request CRL-iD/iH/iDH x 1665 x 712mm CKL-iH-5800, on request CRL-iD/iH/iDH x 2070 x 814mm CRL-9000, CRL-iD/iH/iDH-9000 on request HEATING COIL MODULE For horizontal air routing (L x D x H) 305 x 750 x 508mm CRL-iD/iH/iDH-1300 on request 305 x 955 x 712mm CRL-iD/iH/iDH-2500 on request 305 x 1155 x 712mm CRL-3500 on request 305 x 1360 x 712mm CKL-iH-4400, on request CRL-iD/iH/iDH x 1665 x 712mm CKL-iH-5800, on request CRL-iD/iH/iDH x 2070 x 814mm CRL-iD/iH/iDH-9000 on request WOLF ACCESSORIES

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

Operation and Maintenance Instructions

Operation and Maintenance Instructions Operation and Maintenance Instructions Unit Heaters LH (Translation of the original) Wolf GmbH Postfach 1380 84048 Mainburg Tél. 08751/74-0 Fax 08751/741600 Internet : www.wolf-heiztechnik.de N d art.

More information

Energy-efficient heat source provides comfort in large rooms

Energy-efficient heat source provides comfort in large rooms AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating

More information

WOLF WARM AIR CURTAIN

WOLF WARM AIR CURTAIN TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring

More information

Fan coil unit KL. Wall unit Ceiling unit

Fan coil unit KL. Wall unit Ceiling unit Fan coil unit KL Wall unit Ceiling unit Description Wall unit with casing, top discharge 7 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs up to 6 kw Heating/cooling

More information

Technical documentation Fan coil unit

Technical documentation Fan coil unit Technical documentation Fan coil unit KL wall and ceiling unit Description Wall unit with casing, top discharge 8 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs

More information

WOLF GAS CONDENSING BOILERS COMFORTLINE

WOLF GAS CONDENSING BOILERS COMFORTLINE WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

42AM. Air heaters PRODUCT SELECTION DATA

42AM. Air heaters PRODUCT SELECTION DATA PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of

More information

Halton Rex 600 Basic R6B - Active chilled beam

Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

Passive chilled beams

Passive chilled beams X X testregistrierung Passive chilled beams Type with frame, with perforated metal facing without perforated metal facing, RAL 9005, black Passive chilled beam in nominal lengths of up to 3000 mm and with

More information

Optimal work climate with open doors. Industrial air curtains Model IndAC

Optimal work climate with open doors. Industrial air curtains Model IndAC Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28 The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more

More information

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections

More information

Halton Rex for Vario R6O - Variable air volume chilled beam

Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited

More information

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet S & P Coil Products Limited BELGRAVIA Classic (Vertical Units) - Technical Data Sheet BELGRAVIA CLASSIC: CONSTRUCTION Each Belgravia Classic unit comprises a sheet metal case, fitted with inlet and outlet

More information

Units for suspended cei lings

Units for suspended cei lings . X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022

More information

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................

More information

Technical documentation Comfort domestic ventilation system

Technical documentation Comfort domestic ventilation system Technical documentation Comfort domestic ventilation system CWL Excellent CWL-T Excellent CWL-F Excellent 2 CWL unit options Type CWL-F-150 Excellent CWL-F-300 Excellent CWL-180 Excellent CWL-300 Excellent

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

INDUSTRIAL AIR CURTAIN. IndAC 2

INDUSTRIAL AIR CURTAIN. IndAC 2 INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is

More information

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

HD 7/11-4 Cage Classic

HD 7/11-4 Cage Classic HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan Product Description The Plenum Integrated Filter Fan (PIFF) is a fan filter unit with integrated

More information

Operating instructions

Operating instructions Operating instructions Control unit - CGL Zone 0.0 C Friday 3/0/08 : 6 Wolf GmbH Postfach 380 D-84048 Mainburg Tel. +49 (0)875/74-0 Fax +49 (0)875/74600 Internet: www.wolf-heiztechnik.de Document no.:

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

CHILLED BEAM CASSETTE IQ STAR LYRA

CHILLED BEAM CASSETTE IQ STAR LYRA CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled

More information

Cooling Strip Model SPB

Cooling Strip Model SPB Cooling Strip Model SPB Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

Xpert HD Xpert HD 7140, ,

Xpert HD Xpert HD 7140, , Xpert HD 7140 Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. TECHNICAL

More information

Installation, Operation & Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref: Series AM Fan Convectors Installation, Operation & Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 121-000-001-A UK:www.dunham-bush.co.uk

More information

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

TERM-E ELECTRIC HEATING AND VENTILATION UNITS ELECTRIC HEATING AND VENTILATION UNITS INTENDED USE The heating units with axial fans, metal casing and electric heaters are designed to heat rooms such as: industrial halls, workshops, warehouses, commercial

More information

Halton CHB Active chilled beam with boost function for bulkhead installation

Halton CHB Active chilled beam with boost function for bulkhead installation Halton CHB Active chilled beam with boost function for bulkhead installation Combined cooling, heating, and supply-air unit for bulkhead installation Different sizes, to meet various cooling and air-flow

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,

More information

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW Technical documentation ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW ComfortLine gas condensing boilers Benefits of the WOLF gas condensing boilers up to 24 kw CGB-2(K) / CGW-2 / CGS-2

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Cassette units Model Comfort Circle. - heating - cooling - ventilation Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CT3B Gas condensing boiler for natural gas E, LL and LPG With modulating MatriX

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation Cooling and heating systems Static cooling ceiling system SKS-/3 DS 10 E 01.010 Static cooling ceiling system SKS-/3 Main features Preliminary remarks / Applications 3 Main dimensions and materials 3 Construction

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING TW 0216 SI/Metric TANK WASHING When choosing a suitable tank cleaning nozzle, three different designs are available: Stationary tank cleaning nozzles Rotating

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING Low Water-Temperature system wall and ceiling mounting 2-or 4-Pipe system heating and /or cooling with or without casing easy installation EC motor silent, powerful, economical, sustainable 2-PIPE 4-PIPE

More information

Metropolitan high output natural and powered trench heaters

Metropolitan high output natural and powered trench heaters Metropolitan high output natural and powered trench heaters High output trench heaters Typically used in large glazed areas to reduce glazing losses, these units are the perfect way to enhance comfort.

More information

NEW RANGE OF WARM AIR CURTAINS

NEW RANGE OF WARM AIR CURTAINS NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible

More information

Fan Coil Unit CULTRA

Fan Coil Unit CULTRA Fan Coil Unit CULTRA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR

More information

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb) CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for GRANDIMPIANTI

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for GRANDIMPIANTI GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for GRANDIMPIANTI GRANDIMPIANTI heating elements/thermostats heating elements heater battery No. 4522

More information

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS R8215343-02EN - Edition 02-01/04/2007 Domestic Gas Boilers MICROGENUS PLUS 537814 MICROGENUS PLUS 24 MET...... 3300078 MICROGENUS PLUS 21

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating Air curtains Air curtains The air curtains from VEAB create an effective, separating air trap between two temperature zones, for the entrances of department stores, public spaces, offices, etc. During

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

2.2. Type 90. Safety cabinets for active storage of drums

2.2. Type 90. Safety cabinets for active storage of drums SUPPLY line 162 Type 90 Safety cabinets for active storage of drums 163 SUPPLY line for active storage of drums Type 90 A certified system solution. Fire resistance (FR) of 90 minutes. Safety cabinets

More information

External venetian blinds

External venetian blinds External venetian blinds 115003en/05.2010 Quality of Life WAREMA. 1 E 80 AF SR asymmetrical external venetian blinds Description Interesting facts 4.1 4.2 1 2 3 Application For mounting on mullion and

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella. Contact, Overview, Index Ceiling Heating/Chilled Plexus Professor Pilot Architect Polaris I & S Plafond Podium Celo Cabinett Capella Fasadium Atrium H & C /Loggia Regula Drypac TM Lighting TEKNOsim 0 0.00

More information

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability,

More information

BSK-RPR Fire Damper. Additional operating instructions according to

BSK-RPR Fire Damper. Additional operating instructions according to Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01

More information

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better www.galletti.it Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing 2012 Create value to design better A guide to choosing The group It s 1961 and Galletti with its Jolly copper

More information

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM8 CPM77 CPM96 CPM116 CPMSP116 CPM144 CPM17 CPM_ANCIL/CASCADE_V1._December 201 INDEX 1. INTRODUCTION...3 2. MAIN

More information

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

The green and friendly entrance. Comfort air curtains Model CA 2

The green and friendly entrance. Comfort air curtains Model CA 2 The green and friendly entrance Comfort air curtains Model CA 2 Energy saving and userfriendly air curtain Model CA 2 is the newest addition to the series Biddle comfort air curtains. It is Biddle s conviction

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette Key features The LYRA II cassette is an active chilled beam for ventilation, cooling and heating. This diffusion system offers high flexibility thanks to the combination of Flow Pattern Control, Coanda

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Technical description

Technical description Rail profile grinding machine NRG Technical description Nencki Ltd Railway Technology Gaswerkstrasse 27 4901 Langenthal Switzerland Tel. +41 62 919 93 93 Fax +41 62 919 93 90 railway@nencki.ch www.nencki.ch

More information

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to

More information

Supply air unit VEKA Installation & Maintenance

Supply air unit VEKA Installation & Maintenance November 2008 Safety instructions Operating the air treatment unit and accessory components WARNING Before the air treatment unit is taken into service, any free connections must be provided with protective

More information

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal

More information

BKA-EN Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01

More information

System architecture. Air treatment Index

System architecture. Air treatment Index System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed

More information

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA Installation and service instructions for contractors VIESMANN Vitocell 340-M/360-M Type SVKA Type SVSA Combi cylinder 750 and 950 litre capacity VITOCELL 340-M/360-M 4/2009 Please keep safe. Safety instructions

More information

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE CGB-2(K) / CGW-2 / CGS-2L / CGS-2R / CSZ-2 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

Blower-YEFB-020-3R-1maxVel

Blower-YEFB-020-3R-1maxVel YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk

More information