HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW
|
|
- Christina Wiggins
- 5 years ago
- Views:
Transcription
1 NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE
2 BALANCED VENTILATION WITH HEAT RECOVERY Fresh air intake HRU ECO 3 RF Exhaust bathroom Exhaust kitchen Exhaust ilet Designs for the Future With the Government actively encouraging energy saving and a target for all new homes be carbon zero by 2016, the HRU ECO 3 RF has been designed future proof. The Code for Sustainable Homes which came in force in March 2007, details six levels of CO 2 emission improvement over 2006 Building Regulations requirements. To achieve the three highest levels of reduction of carbon emissions, the air leakage of the dwelling must be improved so significantly that continuous ventilation becomes the only appropriate method. In addition, it must be demonstrated that the ventilation system itself must be energy efficient. The HRU ECO 3 RF has been third party SAP Q 1 tested by the Building Research Establishment (BRE) the apropriate SAP Appendix Q test methodology and is Appendix Q eligible. 1 The Governments Standard Assessment Procedure (SAP) is a method assessing the energy performance of dwellings and SAP Appendix Q provides an allowance for the benefits of energy-saving appliances; products may be independently assessed and the results uploaded the SAP website.
3 Code HRU ECO 3 RF Manufactured lightweight material. Patented airtight clamped construction. Complete with Wall Mounting Bracket. Complete with a length of sound insulating fl exible duct. 95% efficient (NEN 5128) Synthetic Counter Flow Heat Exchanger. Aumatic 100% Suer Bypass. Aumatic Frost protection device. 2 x Backward curved centrifugal fans with energy efficient DC mors. G3 Filters on both the Fresh Air Inlet and the Extract. All parts guaranteed against defect for 2 years. Complete with 2 x Wireless Control Switches. 3 speed settings + boost speed timer function (10 30 minutes). Energy Saving: pre-warmed fresh air lowers the heating requirement. Comfort: slow air movement eliminates draughts. Health: constant fresh air supply. Noisy sites: balanced system with no need for trickle ventilars. Exhaust house Fresh air bedroom The 2006 Edition of the U.K Building Regulations Approved Document F1:Means of Ventilation (applicable in England and Wales) details 4 clearly defined systems of ventilation dwellings. System 4 - Continuous mechanical extract with heat recovery (MVHR) is complied with by the new HRU ECO 3 RF ultra-high efficiency whole house heat recovery ventilation system. The system provides quiet, uninterrupted extract ventilation the dwelling, removing warm stale air via all of the wet rooms, creating a permanent air path through the property the dry habitable rooms. Air, drawn in the property by the fan is routed through an integral high-efficiency synthetic heat exchanger where warmth the extracted air is transferred the incoming fresh air before it is supplied the habitable rooms. In employing this type of system, there is no need install background ventilars in the dwelling - an ideal solution noisy sites. To counter increased pollutants caused by cooking or bathing activities, a wireless boost facility allows the fan s balanced extract and supply rates be increased anywhere in the property where an RF Switch is positioned. The HRU ECO 3 RF unit is equipped with an integrated fully aumated suer bypass valve that ensures that, if required, fresh air drawn in the unit fl ows directly in the air supply system instead of through the heat exchanger; in this instance there is no heat transfer between the warmer discharge air and the cooler supply air. This is a definite advantage in the suer, when air is often cooler than air indoors. An integrated fully aumatic frost protection valve ensures that the unit does not freeze during the colder months. Due the unique clamping construction in combination with the plastic/synthetic elements, the weight of the heat recovery unit HRU ECO 3 RF fan is only 25 kg. Fresh air living room Designed and Manufactured by Itho bv and supplied exclusively in the U.K. by Vortice Limited. All exhaust and supply air connections have an internal diameter of 150 and external 180. The connections can be used attach Vortice modular rigid ducting and insulated fl exible aluminium ducts and accessories. Each connection is provided with an illustration that shows the direction and source of the air. Standard NEN 5128 defines the efficiency of heat recovery units for dwellings. As a result of the efficiency determined a certificate of equivalence for the HRU ECO 3 RF fan has been issued. An efficiency of 95% can be used in the EPC calculation. In addition, the product has successfully passed the test requirements of BS EN308:1997: Heat exchangers. Test procedures for establishing the performance of air air and fl ue gases heat recovery devices.
4 No leakage fresh air exhaust air 1 Heat exchanger tight fitting in the EPP housing. 2 Tape on sides for extra sealing. 3 Bayonet fitting seals the cover the heat exchanger. 4 Patented Clamp Device guarantees air tightness Labelled duct connection 1 Supply Air House. 2 Fresh Air Outside. 3 Exhaust Air House. 4 Exhaust Air Outside Ultra quiet operation 1 Quiet fan. 2 Vibrations damper. 3 Absorbtion foam. 4 Air fl ow speed as low as possible. Capacity adjustable
5 Wireless 3 speed control with timer - RF-Set Timer push 1 x 10 minutes. Timer push 2 x 20 minutes. Timer push 3 x 30 minutes. Normal Operation Mode Frost Protection Mode Suer Bypass Mode
6 DIMENSIONS () AND CERTIFIED PERFORMANCE EXT. Ø F INT. Ø E D A C B Model Code A Height over Body B Width C Height (over connections) Depth Duct connection int. Ø E ext. Ø F Discharge condensate ext. Protection Filter Grade Weight kg HRU ECO 3 RF IP31 G3 24,1 Mode Capacity Pressure Power Current Voltage Power Facr Cos Phi Thermic performance m 3 /h Pa W A V * % Mode 1 Minimum mode , ,07 98 Mode 1 Low mode , ,55 98 Mode 2 Medium mode , ,53 96,2 Mode 2 Medium mode , ,53 96,2 Mode 3 High mode , ,59 94 Mode 3 High mode , ,56 94 Mode 3 High mode , ,56 93 Mode 3 High mode , ,56 93 Mode 3 Maximum mode , ,56 92 Mode 3 Maximum mode , ,56 92 * Values entered in the EPC calculation NEN 5128
7 BUILDING REGULATIONS DOCUMENT F Continuous mechanical supply & extract ventilation with heat recovery A continuous balanced mechanical central supply and extract system be positioned in loft or cupboard space. An integral heat exchanger recovers a large percentage of heat energy that would have otherwise been lost. In employing this type of system, there is no need install background ventilars in the dwelling. Continuous supply and extract 1 Determine the whole building ventilation rate Table 1.1B Allow for infiltration by subtracting - for multi srey dwellings: 0.04 x gross internal volume of dwelling heated space (m 3 ). - for single srey dwellings: 0.06 x gross internal volume of dwelling heated space (m 3 ). 2 Calculate the whole dwelling extract rate at maximum operation by adding the individual room rates for minimum high rate Table 1.1A. 3 The required air flow rates are as follows: Maximum Extract Rate (boost) is the greater step of 1 and 2 above. The Minimum individual room extract rates should be at least those given in Table 1.1A for minimum high rate Minimum air supply rate should be at least the whole building ventilation rate in 1 above. 4 No Background ventilars are required with System 4. Table 1.1 A Room Minimum intermittent extract rate Continuous rate Minimum high rate Minimum low rate Kitchen 30 l/s (adjacent hob); or 60 l/s elsewhere 13 l/s Utility room 30 l/s 8 l/s Bathroom 15 l/s 8 l/s Sanitary Accomodation 6 l/s 6 l/s Total extract rate must be at least the whole building ventilation rate in Table 1.1B Table 1.1 B Number of bedrooms in dwelling Whole building ventilation rate (l/s) Minimum value in any dwelling of 0,3 l/s per m 2 fl oor area In addition, the minimum ventilation rate should not be less than 0,3 l/s per m 2 internal fl oor area (this includes each fl oor, e.g. for a two-srey building, add the ground and fi rst fl oor areas). This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as thedefault value. If a greater level of occupance is expected, then add 4 l/s per occupant.
8 ACCESSORIES CODE DESCRIPTION Fixed Grille 125/150 Diameter (Grey) 8224 Fixed Grille 150 Diameter (White) EXTERNAL TERMINALS AND 8227 Fixed Grille 150 Diameter (Brown) ASSOCIATED COMPONENTS 8230 Fixed Grille 150 Diameter (Beige) 8233 Fixed Grille 150 Diameter (Terracotta) 9104 Semi-rigid Wall Liner 150 Diameter 8136 Spigot Plate 150 Diameter 8340 Insulated Flexible Ducting 100 Diameter X 4 m Length 8331 Insulated Flexible Ducting 100 Diameter X 10 m Length INSULATED FLEXIBLE 8342 Insulated Flexible Ducting 125 Diameter X 4 m Length ALUMINIUM DUCTING 8333 Insulated Flexible Ducting 125 Diameter X 10 m Length 8341 Insulated Flexible Ducting 150 Diameter X 4 m Length 8332 Insulated Flexible Ducting 150 Diameter X 10 m Length 8681 Y-piece 100 Diameter 8682 Y-piece 125 Diameter 8683 Y-piece 150 Diameter 8174 Duct Joining Piece 100 Diameter 8415 Duct Joining Piece 125 Diameter 8672 Duct Joining Piece 150 Diameter 8063 Reducer Diameter FLEXIBLE DUCTING COMPONENTS 9239 Reducer Diameter 9238 Reducer Diameter 9807 Reducer Diameter 8039 Worm Drive Clip 100 Diameter 8040 Worm Drive Clip 125 Diameter 8041 Worm Drive Clip 150 Diameter 8042 Worm Drive Clip 200 Diameter 8020 Pvc Sealing Tape 8410 Flat Channel 1,0 m Length 8416 Flat Channel 1,5 m Length 8406 Connecr 8412 T-piece 8417 Round-square 90 Degree Bend 125 Diameter FLAT DUCTING 8427 Round-square 90 Degree Bend 150 Diameter 8409 Round-square Adapr 125 Diameter 8414 Horizontal 90 Degree Bend 8420 Horizontal 45 Degree Bend 8408 Vertical 90 Degree Bend 8418 Rectangular Pvc Hose 8419 Mounting Strap ROOM TERMINALS 8048 Duct Valve 100 Diameter 8049 Duct Valve 125 Diameter SWITCH 9806 RF Switch - White REPLACEMENT PARTS 9808 Replacement Filter 9809 Replacement Heat Exchanger
9 KOVENT Kumanovska 14, Beograd Tel Faks
HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW
NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE
More informationKair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery
Kair VENTILATION LIMITED ieco 4 RANGE Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with
More informationNEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE
NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with
More informationHRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible
HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic
More informationCVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible
CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and
More informationNEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE
NEW Vort PROMETEO PLUS HR400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE TM 1 TM VORT PROMETEO PLUS RANGE HEAT RECOVERY UNITS Product specifications: NEW 2 models: vort
More informationBuilding Regulations 2010: What it means to you.
Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both
More informationItho Advance heat recovery ventilation unit. comfortable. indoor climate
Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has
More informationInstallation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system
Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the
More informationMRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation
NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent
More informationSPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger
WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet
More informationInstallation and Maintenance
1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1
More informationInstallation and Maintenance
1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for
More informationMRXBOXAB-ECO3 MRXBOX-ECO3
NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due
More informationMRXBOXAB-ECO2 MRXBOX-ECO2
NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due
More informationVentilation Product range ADVANCE ECO 4 ECO 2
Product range ADVANCE ECO 4 ECO 2 Air, we breathe it without thinking. Keeping it that way in the modern, airtight homes calls for class-leading ventilation performance and you will find this with the
More informationenergisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System
energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava
More informationHRU ECO 4. installer manual
HRU ECO 4 installer manual 2 Table of contents 1. General information 4 1.1 Introduction 4 1.2 Warranty and liability 4 1.3 Safety 5 2. Technical information 6 2.1 General description 6 2.2 Description
More informationSmall Room Heat Recovery Ventilation
Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room
More informationInstallation and Maintenance
1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The
More informationMECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)
MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and
More informationSlimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range
& 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally
More informationResidential Carbon Friendly Ventilation SAP Q Eligible. ventilation
Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the
More informationMRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT
- WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.
More informationBuilding Regulations Approved Document F1 Means of Ventilation April 2006
Building Regulations Approved Document F1 Means of Ventilation April 2006 BPD Structure BUILDING PRODUCT DESIGN LTD 4 trading divisions.. Natural ventilation products and systems Roofing products, flat
More informationCI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units
CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations
More informationInstallation and Maintenance
MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive
More informationMRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)
NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1
More informationLo-Carbon Sentinel Kinetic Horizontal
Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up
More informationMECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE
NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation
More informationInstallation and Maintenance
38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance
More informationNEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT
NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective with a Thermal Efficiency up to 92 % Energy Saving Lowers
More informationCI/SfB (57.5) November 2008
CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide
More informationInstallation and Maintenance
MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive
More informationInstallation and Maintenance
MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low
More informationIntake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside
Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat
More informationHRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.
HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either
More informationCode of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)
Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards
More informationIntake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside
MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting
More informationMODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual
90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:
More informationHealthy, comfortable and energy-efficient ventilation
Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical
More informationAcoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2
NUAIRE S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard
More informationMechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system
Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat
More informationMRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside
MRXOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction The unit must
More informationCI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans
CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia
More informationenergisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems
energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor
More informationMRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance
MRXBOX95AB-WH1 Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction
More informationIntroducing the RetroVent
Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed
More informationThat allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS
Heat Recovery Units Balanced ventilation brings comfort and health to your home throughout the year. After all, wouldn t you like to always have plenty of clean, fresh air in your home? HRV ensures t hat
More informationWHHR Midi & Midi Lite
WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page
More informationHOTLINE:
You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore
More informationMODEL: BV400 Part No:
MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...
More informationSPECIFICATION GUIDE. Tel DOMUS VENTILATION
SPECIFICATION GUIDE Tel 3443 715 523 www.domusventilation.co.uk @DomusVent DOMUS VENTILATION Contents Introduction 3 Best Practice Guide 4 Indoor Air Quality 8 Mechanical Ventilation Products 9 DME Controls
More informationHealthy, comfortable and energy-efficient ventilation
Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical
More informationHRV Enthalpy. Catalogue
HRV Enthalpy Catalogue BM896 Iss 02 - Enthalpy MVHR Contents HRV1.35 Q Plus - Enthalpy...3 HRV2 Q Plus - Enthalpy...5 HRV3 Q Plus - Enthalpy...7 HRV10.25 Q Plus - Enthalpy...9 Heat Water vapour Gases and
More informationenergisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER
energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION
More informationMEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER
MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make
More informationItho CVE ECO 2 RFT. Installer/User manual
Itho CVE ECO 2 RFT Installer/User manual Safety Warning - Do not use this appliance for functions other than those described in the booklet - After removing the appliance from its packaging, ensure that
More informationMRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside
MRXBOX95-WM2 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must
More informationMRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket
MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must
More informationThe Sentinel Kinetic Horizontal Range
Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery
More informationAirflex Radial & ISO Thermal pipe
Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)
More informationPolypipe Ventilation Specifiers Guide
Uniclass L75344 CI/SfB (57.5) X PVSB-2 May 215 Polypipe Ventilation Specifiers Guide Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Intermittent Extract and Decentralised Mechanical
More informationMRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance
MRXBOX95-WM2H Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0
More informationMVHR & MEV VENTILATION GUIDE 2017
MVHR & MEV VENTILATION GUIDE 2017 Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Rigid and Semi-Rigid Duct Systems 1 All prices quoted exclude VAT and do not include trade discounts.
More informationWHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR
Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides
More informationCOUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT
Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant airflow setting, very low consumption EC motor and low sound level. Provides a constant supply of fresh tempered
More informationHeat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing
Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation
More informationThank you for choosing EnviroVent
01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed
More informationHEAT RECOVERY VENTILATION For healthy, energy efficient ventilation
HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation Heat Recovery Ventilation (HRV) is an integral part of the Passive House approach to achieving ultra-low energy houses. In the UK, HRV
More informationMRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY
MECHAICA VETIATIO WITH HEAT RECOVERY UP TO 95% EFFICIET, SAP APPEDIX Q RECOGISED. WA/CUPOARD MOUTIG DESIG FOR MEDIUM TO ARGE HOUSES & APARTMETS. 36 029 2085 8200 EEFITS is designed to provide optimised
More informationZehnder Comfosystems. ComfoAir 180 Datasheet
Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an
More informationVENTILATION AND HEAT RECOVERY
VENTILATION AND HEAT RECOVERY In last month s article we looked at the energy cost of ventilation. The cost of the heat lost when stale air is extracted is much greater than any energy used by fans. But
More informationMECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE
MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE 1 Advance Plus, ECO 4 & ECO 2. Mechanical ventilation and heat recovery systems for your home. Mechanical ventilation and heat recovery systems provide
More informationThe new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE
Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for PERFORMANCE The new generation of MVHR units - ComfoAir Q Introduction
More informationThe Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES
The Range 1 HIGHEST INDOOR AIR QUALITY IN NEW HOMES NUAIRE S Q-AIRE Innovation at its best Since our inception in 1966, we have pioneered a number of new ventilation strategies and products now widely
More informationShort Form Ventilation Product Guide
Uniclass L7534 CI/SfB (57) X FVSF-2 May 2015 Short Form Ventilation Product Guide FERROB VENTILATION design, manufacture and install specialist domestic and light commercial ventilation products for landlords,
More informationChrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover
Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when
More informationDC Heat Recovery Unit MVHR Wholehouse heat recovery unit
DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.
More informationIntelligent Air Solutions
Uniclass L75 CI/SfB (57) X HRX-aQSB. May 06 Intelligent Air Solutions QUIET COMPACT EFFICIENT MANUFACTURED IN THE UK Applications Suitable applications Introducing Polypipe s new and highly efficient Silavent
More informationComfoAir Q. Mechanical Ventilation and Heat Recovery
ComfoAir Q Mechanical Ventilation and Heat Recovery 2 MVHR by OMNIE Optimum indoor ventilation The ComfoAir Q from OMNIE is the NEW generation of heat recovery ventilation units, with state of the art
More informationenergisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER
energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION
More informationApartment Ventilation. "Microbox" Continuous Mechanical Extract Units
Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation
More informationSUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM
SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation
More informationCentair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions
Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide
More informationI tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED
I tho Advance Heat recovery ventilation unit User manual 226-0048/0111/ED 210.0998 A6_226-0048 Ventilator Advance ENGELS.indd 1 04-01-11 14:32 2 Contents 1. Introduction 4 1.1 Configuration 4 1.2 Itho
More informationIDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control
Counter-flow, high-efficiency heat recovery unit Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant flow, setting and very low consumption DC motor. Provides a
More informationPut the V back in HVAC
Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed
More informationDomestic & Commercial Fans
Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO
More informationPLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.
Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,
More informationVentilation. Product Information
Ventilation Product Information Residential Lossnay Unit The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is an energy efficient whole house ventilation solution which provides
More informationEnergy Efficient Air Distribution Systems
(57.7) X from Polypipe Ventilation Energy Efficient Air Distribution Systems VSPweb On-line Planner Providing Duct Systems for: Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation
More informationInspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV
Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators
More informationTechnical Bulletin 005(B) Developed with Building Standards Scotland
Technical Bulletin 005(B) Developed with Building Standards Scotland Title: Gas cookers in internal kitchens - Ventilation requirements as applied to Scotland Date issued: 1 July 2015 Note: This version
More informationCREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)
CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We
More informationMRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance
MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction
More informationPERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for
Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for PERFORMANCE The new generation of MVHR units - ComfoAir Q Introduction
More informationContents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...
Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5
More informationLo-Carbon Sentinel Kinetic Range Overview
Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q Specific
More informationVentilation & Heat Recovery. The whole house system from OMNIE
Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit
More information