HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Size: px
Start display at page:

Download "HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW"

Transcription

1 NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

2 BALANCED VENTILATION WITH HEAT RECOVERY Fresh air intake HRU ECO 3 RF Exhaust bathroom Exhaust kitchen Exhaust ilet Designs for the Future With the Government actively encouraging energy saving and a target for all new homes be carbon zero by 2016, the HRU ECO 3 RF has been designed future proof. The Code for Sustainable Homes which came in force in March 2007, details six levels of CO 2 emission improvement over 2006 Building Regulations requirements. To achieve the three highest levels of reduction of carbon emissions, the air leakage of the dwelling must be improved so significantly that continuous ventilation becomes the only appropriate method. In addition, it must be demonstrated that the ventilation system itself must be energy efficient. The HRU ECO 3 RF has been third party SAP Q 1 tested by the Building Research Establishment (BRE) the apropriate SAP Appendix Q test methodology and is Appendix Q eligible. 1 The Governments Standard Assessment Procedure (SAP) is a method assessing the energy performance of dwellings and SAP Appendix Q provides an allowance for the benefits of energy-saving appliances; products may be independently assessed and the results uploaded the SAP website.

3 Code HRU ECO 3 RF Manufactured lightweight material. Patented airtight clamped construction. Complete with Wall Mounting Bracket. Complete with a length of sound insulating fl exible duct. 95% efficient (NEN 5128) Synthetic Counter Flow Heat Exchanger. Aumatic 100% Suer Bypass. Aumatic Frost protection device. 2 x Backward curved centrifugal fans with energy efficient DC mors. G3 Filters on both the Fresh Air Inlet and the Extract. All parts guaranteed against defect for 2 years. Complete with 2 x Wireless Control Switches. 3 speed settings + boost speed timer function (10 30 minutes). Energy Saving: pre-warmed fresh air lowers the heating requirement. Comfort: slow air movement eliminates draughts. Health: constant fresh air supply. Noisy sites: balanced system with no need for trickle ventilars. Exhaust house Fresh air bedroom The 2006 Edition of the U.K Building Regulations Approved Document F1:Means of Ventilation (applicable in England and Wales) details 4 clearly defined systems of ventilation dwellings. System 4 - Continuous mechanical extract with heat recovery (MVHR) is complied with by the new HRU ECO 3 RF ultra-high efficiency whole house heat recovery ventilation system. The system provides quiet, uninterrupted extract ventilation the dwelling, removing warm stale air via all of the wet rooms, creating a permanent air path through the property the dry habitable rooms. Air, drawn in the property by the fan is routed through an integral high-efficiency synthetic heat exchanger where warmth the extracted air is transferred the incoming fresh air before it is supplied the habitable rooms. In employing this type of system, there is no need install background ventilars in the dwelling - an ideal solution noisy sites. To counter increased pollutants caused by cooking or bathing activities, a wireless boost facility allows the fan s balanced extract and supply rates be increased anywhere in the property where an RF Switch is positioned. The HRU ECO 3 RF unit is equipped with an integrated fully aumated suer bypass valve that ensures that, if required, fresh air drawn in the unit fl ows directly in the air supply system instead of through the heat exchanger; in this instance there is no heat transfer between the warmer discharge air and the cooler supply air. This is a definite advantage in the suer, when air is often cooler than air indoors. An integrated fully aumatic frost protection valve ensures that the unit does not freeze during the colder months. Due the unique clamping construction in combination with the plastic/synthetic elements, the weight of the heat recovery unit HRU ECO 3 RF fan is only 25 kg. Fresh air living room Designed and Manufactured by Itho bv and supplied exclusively in the U.K. by Vortice Limited. All exhaust and supply air connections have an internal diameter of 150 and external 180. The connections can be used attach Vortice modular rigid ducting and insulated fl exible aluminium ducts and accessories. Each connection is provided with an illustration that shows the direction and source of the air. Standard NEN 5128 defines the efficiency of heat recovery units for dwellings. As a result of the efficiency determined a certificate of equivalence for the HRU ECO 3 RF fan has been issued. An efficiency of 95% can be used in the EPC calculation. In addition, the product has successfully passed the test requirements of BS EN308:1997: Heat exchangers. Test procedures for establishing the performance of air air and fl ue gases heat recovery devices.

4 No leakage fresh air exhaust air 1 Heat exchanger tight fitting in the EPP housing. 2 Tape on sides for extra sealing. 3 Bayonet fitting seals the cover the heat exchanger. 4 Patented Clamp Device guarantees air tightness Labelled duct connection 1 Supply Air House. 2 Fresh Air Outside. 3 Exhaust Air House. 4 Exhaust Air Outside Ultra quiet operation 1 Quiet fan. 2 Vibrations damper. 3 Absorbtion foam. 4 Air fl ow speed as low as possible. Capacity adjustable

5 Wireless 3 speed control with timer - RF-Set Timer push 1 x 10 minutes. Timer push 2 x 20 minutes. Timer push 3 x 30 minutes. Normal Operation Mode Frost Protection Mode Suer Bypass Mode

6 DIMENSIONS () AND CERTIFIED PERFORMANCE EXT. Ø F INT. Ø E D A C B Model Code A Height over Body B Width C Height (over connections) Depth Duct connection int. Ø E ext. Ø F Discharge condensate ext. Protection Filter Grade Weight kg HRU ECO 3 RF IP31 G3 24,1 Mode Capacity Pressure Power Current Voltage Power Facr Cos Phi Thermic performance m 3 /h Pa W A V * % Mode 1 Minimum mode , ,07 98 Mode 1 Low mode , ,55 98 Mode 2 Medium mode , ,53 96,2 Mode 2 Medium mode , ,53 96,2 Mode 3 High mode , ,59 94 Mode 3 High mode , ,56 94 Mode 3 High mode , ,56 93 Mode 3 High mode , ,56 93 Mode 3 Maximum mode , ,56 92 Mode 3 Maximum mode , ,56 92 * Values entered in the EPC calculation NEN 5128

7 BUILDING REGULATIONS DOCUMENT F Continuous mechanical supply & extract ventilation with heat recovery A continuous balanced mechanical central supply and extract system be positioned in loft or cupboard space. An integral heat exchanger recovers a large percentage of heat energy that would have otherwise been lost. In employing this type of system, there is no need install background ventilars in the dwelling. Continuous supply and extract 1 Determine the whole building ventilation rate Table 1.1B Allow for infiltration by subtracting - for multi srey dwellings: 0.04 x gross internal volume of dwelling heated space (m 3 ). - for single srey dwellings: 0.06 x gross internal volume of dwelling heated space (m 3 ). 2 Calculate the whole dwelling extract rate at maximum operation by adding the individual room rates for minimum high rate Table 1.1A. 3 The required air flow rates are as follows: Maximum Extract Rate (boost) is the greater step of 1 and 2 above. The Minimum individual room extract rates should be at least those given in Table 1.1A for minimum high rate Minimum air supply rate should be at least the whole building ventilation rate in 1 above. 4 No Background ventilars are required with System 4. Table 1.1 A Room Minimum intermittent extract rate Continuous rate Minimum high rate Minimum low rate Kitchen 30 l/s (adjacent hob); or 60 l/s elsewhere 13 l/s Utility room 30 l/s 8 l/s Bathroom 15 l/s 8 l/s Sanitary Accomodation 6 l/s 6 l/s Total extract rate must be at least the whole building ventilation rate in Table 1.1B Table 1.1 B Number of bedrooms in dwelling Whole building ventilation rate (l/s) Minimum value in any dwelling of 0,3 l/s per m 2 fl oor area In addition, the minimum ventilation rate should not be less than 0,3 l/s per m 2 internal fl oor area (this includes each fl oor, e.g. for a two-srey building, add the ground and fi rst fl oor areas). This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as thedefault value. If a greater level of occupance is expected, then add 4 l/s per occupant.

8 ACCESSORIES CODE DESCRIPTION Fixed Grille 125/150 Diameter (Grey) 8224 Fixed Grille 150 Diameter (White) EXTERNAL TERMINALS AND 8227 Fixed Grille 150 Diameter (Brown) ASSOCIATED COMPONENTS 8230 Fixed Grille 150 Diameter (Beige) 8233 Fixed Grille 150 Diameter (Terracotta) 9104 Semi-rigid Wall Liner 150 Diameter 8136 Spigot Plate 150 Diameter 8340 Insulated Flexible Ducting 100 Diameter X 4 m Length 8331 Insulated Flexible Ducting 100 Diameter X 10 m Length INSULATED FLEXIBLE 8342 Insulated Flexible Ducting 125 Diameter X 4 m Length ALUMINIUM DUCTING 8333 Insulated Flexible Ducting 125 Diameter X 10 m Length 8341 Insulated Flexible Ducting 150 Diameter X 4 m Length 8332 Insulated Flexible Ducting 150 Diameter X 10 m Length 8681 Y-piece 100 Diameter 8682 Y-piece 125 Diameter 8683 Y-piece 150 Diameter 8174 Duct Joining Piece 100 Diameter 8415 Duct Joining Piece 125 Diameter 8672 Duct Joining Piece 150 Diameter 8063 Reducer Diameter FLEXIBLE DUCTING COMPONENTS 9239 Reducer Diameter 9238 Reducer Diameter 9807 Reducer Diameter 8039 Worm Drive Clip 100 Diameter 8040 Worm Drive Clip 125 Diameter 8041 Worm Drive Clip 150 Diameter 8042 Worm Drive Clip 200 Diameter 8020 Pvc Sealing Tape 8410 Flat Channel 1,0 m Length 8416 Flat Channel 1,5 m Length 8406 Connecr 8412 T-piece 8417 Round-square 90 Degree Bend 125 Diameter FLAT DUCTING 8427 Round-square 90 Degree Bend 150 Diameter 8409 Round-square Adapr 125 Diameter 8414 Horizontal 90 Degree Bend 8420 Horizontal 45 Degree Bend 8408 Vertical 90 Degree Bend 8418 Rectangular Pvc Hose 8419 Mounting Strap ROOM TERMINALS 8048 Duct Valve 100 Diameter 8049 Duct Valve 125 Diameter SWITCH 9806 RF Switch - White REPLACEMENT PARTS 9808 Replacement Filter 9809 Replacement Heat Exchanger

9 KOVENT Kumanovska 14, Beograd Tel Faks

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Kair VENTILATION LIMITED ieco 4 RANGE Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with

More information

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic

More information

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and

More information

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE NEW Vort PROMETEO PLUS HR400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE TM 1 TM VORT PROMETEO PLUS RANGE HEAT RECOVERY UNITS Product specifications: NEW 2 models: vort

More information

Building Regulations 2010: What it means to you.

Building Regulations 2010: What it means to you. Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

Ventilation Product range ADVANCE ECO 4 ECO 2

Ventilation Product range ADVANCE ECO 4 ECO 2 Product range ADVANCE ECO 4 ECO 2 Air, we breathe it without thinking. Keeping it that way in the modern, airtight homes calls for class-leading ventilation performance and you will find this with the

More information

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava

More information

HRU ECO 4. installer manual

HRU ECO 4. installer manual HRU ECO 4 installer manual 2 Table of contents 1. General information 4 1.1 Introduction 4 1.2 Warranty and liability 4 1.3 Safety 5 2. Technical information 6 2.1 General description 6 2.2 Description

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

Building Regulations Approved Document F1 Means of Ventilation April 2006

Building Regulations Approved Document F1 Means of Ventilation April 2006 Building Regulations Approved Document F1 Means of Ventilation April 2006 BPD Structure BUILDING PRODUCT DESIGN LTD 4 trading divisions.. Natural ventilation products and systems Roofing products, flat

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective with a Thermal Efficiency up to 92 % Energy Saving Lowers

More information

CI/SfB (57.5) November 2008

CI/SfB (57.5) November 2008 CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat

More information

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery. HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either

More information

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 NUAIRE S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor

More information

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance MRXBOX95AB-WH1 Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS Heat Recovery Units Balanced ventilation brings comfort and health to your home throughout the year. After all, wouldn t you like to always have plenty of clean, fresh air in your home? HRV ensures t hat

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

MODEL: BV400 Part No:

MODEL: BV400 Part No: MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...

More information

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

SPECIFICATION GUIDE. Tel DOMUS VENTILATION SPECIFICATION GUIDE Tel 3443 715 523 www.domusventilation.co.uk @DomusVent DOMUS VENTILATION Contents Introduction 3 Best Practice Guide 4 Indoor Air Quality 8 Mechanical Ventilation Products 9 DME Controls

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

HRV Enthalpy. Catalogue

HRV Enthalpy. Catalogue HRV Enthalpy Catalogue BM896 Iss 02 - Enthalpy MVHR Contents HRV1.35 Q Plus - Enthalpy...3 HRV2 Q Plus - Enthalpy...5 HRV3 Q Plus - Enthalpy...7 HRV10.25 Q Plus - Enthalpy...9 Heat Water vapour Gases and

More information

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

Itho CVE ECO 2 RFT. Installer/User manual

Itho CVE ECO 2 RFT. Installer/User manual Itho CVE ECO 2 RFT Installer/User manual Safety Warning - Do not use this appliance for functions other than those described in the booklet - After removing the appliance from its packaging, ensure that

More information

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXBOX95-WM2 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

Airflex Radial & ISO Thermal pipe

Airflex Radial & ISO Thermal pipe Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)

More information

Polypipe Ventilation Specifiers Guide

Polypipe Ventilation Specifiers Guide Uniclass L75344 CI/SfB (57.5) X PVSB-2 May 215 Polypipe Ventilation Specifiers Guide Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Intermittent Extract and Decentralised Mechanical

More information

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance MRXBOX95-WM2H Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0

More information

MVHR & MEV VENTILATION GUIDE 2017

MVHR & MEV VENTILATION GUIDE 2017 MVHR & MEV VENTILATION GUIDE 2017 Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Rigid and Semi-Rigid Duct Systems 1 All prices quoted exclude VAT and do not include trade discounts.

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant airflow setting, very low consumption EC motor and low sound level. Provides a constant supply of fresh tempered

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation Heat Recovery Ventilation (HRV) is an integral part of the Passive House approach to achieving ultra-low energy houses. In the UK, HRV

More information

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY MECHAICA VETIATIO WITH HEAT RECOVERY UP TO 95% EFFICIET, SAP APPEDIX Q RECOGISED. WA/CUPOARD MOUTIG DESIG FOR MEDIUM TO ARGE HOUSES & APARTMETS. 36 029 2085 8200 EEFITS is designed to provide optimised

More information

Zehnder Comfosystems. ComfoAir 180 Datasheet

Zehnder Comfosystems. ComfoAir 180 Datasheet Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an

More information

VENTILATION AND HEAT RECOVERY

VENTILATION AND HEAT RECOVERY VENTILATION AND HEAT RECOVERY In last month s article we looked at the energy cost of ventilation. The cost of the heat lost when stale air is extracted is much greater than any energy used by fans. But

More information

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE 1 Advance Plus, ECO 4 & ECO 2. Mechanical ventilation and heat recovery systems for your home. Mechanical ventilation and heat recovery systems provide

More information

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for PERFORMANCE The new generation of MVHR units - ComfoAir Q Introduction

More information

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES The Range 1 HIGHEST INDOOR AIR QUALITY IN NEW HOMES NUAIRE S Q-AIRE Innovation at its best Since our inception in 1966, we have pioneered a number of new ventilation strategies and products now widely

More information

Short Form Ventilation Product Guide

Short Form Ventilation Product Guide Uniclass L7534 CI/SfB (57) X FVSF-2 May 2015 Short Form Ventilation Product Guide FERROB VENTILATION design, manufacture and install specialist domestic and light commercial ventilation products for landlords,

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Intelligent Air Solutions

Intelligent Air Solutions Uniclass L75 CI/SfB (57) X HRX-aQSB. May 06 Intelligent Air Solutions QUIET COMPACT EFFICIENT MANUFACTURED IN THE UK Applications Suitable applications Introducing Polypipe s new and highly efficient Silavent

More information

ComfoAir Q. Mechanical Ventilation and Heat Recovery

ComfoAir Q. Mechanical Ventilation and Heat Recovery ComfoAir Q Mechanical Ventilation and Heat Recovery 2 MVHR by OMNIE Optimum indoor ventilation The ComfoAir Q from OMNIE is the NEW generation of heat recovery ventilation units, with state of the art

More information

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED I tho Advance Heat recovery ventilation unit User manual 226-0048/0111/ED 210.0998 A6_226-0048 Ventilator Advance ENGELS.indd 1 04-01-11 14:32 2 Contents 1. Introduction 4 1.1 Configuration 4 1.2 Itho

More information

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control Counter-flow, high-efficiency heat recovery unit Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant flow, setting and very low consumption DC motor. Provides a

More information

Put the V back in HVAC

Put the V back in HVAC Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

Ventilation. Product Information

Ventilation. Product Information Ventilation Product Information Residential Lossnay Unit The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is an energy efficient whole house ventilation solution which provides

More information

Energy Efficient Air Distribution Systems

Energy Efficient Air Distribution Systems (57.7) X from Polypipe Ventilation Energy Efficient Air Distribution Systems VSPweb On-line Planner Providing Duct Systems for: Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation

More information

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators

More information

Technical Bulletin 005(B) Developed with Building Standards Scotland

Technical Bulletin 005(B) Developed with Building Standards Scotland Technical Bulletin 005(B) Developed with Building Standards Scotland Title: Gas cookers in internal kitchens - Ventilation requirements as applied to Scotland Date issued: 1 July 2015 Note: This version

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction

More information

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for PERFORMANCE The new generation of MVHR units - ComfoAir Q Introduction

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q Specific

More information

Ventilation & Heat Recovery. The whole house system from OMNIE

Ventilation & Heat Recovery. The whole house system from OMNIE Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit

More information