System Installation HYBRID BACK-UP

Size: px
Start display at page:

Download "System Installation HYBRID BACK-UP"

Transcription

1 System Installation HYRID CK-UP

2

3 TLE OF CONTTS INTRODUCTION 1 Instructions guidance Product documentation ssociated documents Explanation of symbols Guarantee registration System description Concept of operation Summary of installation diagrams Diagram 10: eus heat pump, eus boiler, one heating zone Diagram 3: Heat pump eus, boiler controlled by 24V On/Off contact, one heating zone Diagram 13: Heat pump eus, boiler controlled by 230V On/Off contact, one heating zone Diagram 5: Heat pump controlled by On/Off contact, boiler eus/h2us, one heating zone Diagram 6: Heat pump controlled by On/Off contact, boiler controlled by 230V On/ Off contact, one heating zone Example installation with multi-zone heating option Example of system installation with the domestic hot water cylinder option...16 INSTLLTION 3 Configuring the installation "Thermostat / sensor" menu Thermostat(s) Outdoor sensor Self check Settings Heating Domestic hot water Cooling Energy management Resetting parameters Commissioning Filling the heating circuit Venting the heating circuit Venting the HP circuit djustment of HP circuit flow Status reports Re-check and restart User information MINTNCE 11 Trouble-shooting Fault diagnosis System fault codes Servicing Control unit maintenance menu Test menu ftersales information

4 INTRODUCTION INTRODUCTION 1 Instructions guidance 1.1 Product documentation 1.4 Guarantee registration We recommend you complete and return as soon as possible your guarantee registration card (delivered with the hydraulic module). If your guarantee registration card is missing you can obtain a copy or record your registration by telephoning the Glow-worm Customer Service number The instructions are an integral part of the system appliances and must be handed to the user on completion of the installation in order to comply with the current regulation. Carefully read the manual, to understand all the information to enable safe installation, use and servicing. No liability can be accepted in the event of damage for not complying with the guidance in this instruction manual. These instructions consist of, Installation, Servicing, Fault Finding. The instructions are an integral part of the appliance and must be handed to the user on completion of the installation. 1.2 ssociated documents - Heat pump use and installation instructions - Hydraulic module installation instructions - Systempro Control unit use and installation instructions - Climapro2 RF programmable Room thermostat use and installation instructions - Wireless outdoor sensor installation instructions - ccessories installation instructions (motorized 2 port valve...) 1.3 Explanation of symbols a DNGER: e DNGER: b TTTION: i IMPORTNT: Risk of injuries. Risk of electric shock. Risk of damage to the appliance or to its surroundings. Important information

5 INTRODUCTION 2 System description 2.1 Concept of operation The Hybrid ack-up system consists of the following components: - Glow-worm Envirosorb 5 heat pump, - "Universal" hydraulic module, - boiler, - The Systempro control unit, 2.2 Summary of installation diagrams Hybrid ack-up Heat Pump oiler Diagram Envirosorb 5 Envirosorb 2 7 Envirosorb 2 12 Envirosorb 2 15 eus controlled by on/off contact eus 10 controlled by 24V on/off contact 3 controlled by 230V on/off contact 13 eus/h2bus 5 controlled by 230V on/off contact 6 - Climapro2 RF wireless programmable room thermostat, - wireless photovoltaic outdoor sensor The following options may be added to the system: - 2 port valves for zoning, - domestic hot water cylinder Operating principle of the heating system - The home's heat is generated by either the heat pump or the boiler, dependant on outdoor weather conditions, and the energy prices paid for gas and electricity. - The software in the Systempro control unit constantly monitors outdoor temperature, and the co-efficient of Performance (COP). The control unit then decides when to switch between the heat pump or the boiler to maintain comfort levels, whilst maximising the efficiency of the system. The switchover point must be determined in accordance with the respective energy costs (see the "ctivation of control unit > Settings> Energy management" chapter) Operating principle of the domestic hot water system The domestic hot water heating circuit consists of a boiler, a 2 port valve and a domestic hot water cylinder. In order to always obtain the best comfort/economy trade-off, the heat pump and/or the boiler provide the energy needed to maintain the stored water at the required temperature. The lower the hot water temperature setting, the more the heat pump will provide energy and, therefore, more economic operation

6 INTRODUCTION 2.3 Diagram 10: eus heat pump, eus boiler, one heating zone EUS V 3 2 D C 9 10 G 1 12 F E V 8 US 10 NL 7 2 NL - 4 -

7 INTRODUCTION Key 1 Overheating safety (UFH shown, but can be underfloor or radiators) 2 Hydraulic module 3 Heating circuit 4 Climapro2 RF programmable wireless room thermostat 5 Systempro control unit 6 Wireless outdoor sensor 7 Eus boiler 8 Heat pump electrical supply + protection (This must have it's own single isolation) 9 Non-return valve (recommended to prevent burner ignition triggered by thermo-siphoning) 10 Eus heat pump 11 Heat pump circuit filter (not supplied) 12 Glycol PRV discharge C D E F G Heating circuit return Heating circuit flow oiler circuit return oiler circuit flow Heat pump circuit flow Heat pump circuit return Heat pump circuit safety valve discharge pplication conditions - The Systempro control unit manages the operation of the boiler, the heat pump and the module. - The Systempro control unit manages up to 3 heating zones. - Each wireless room thermostat can control a heating zone. - The installation can be performed with a low-temperature underfloor heating (heating outlet temperature < 50 C) or low temperature radiators (heating outlet temperature < 70 C). e Use 0.75 mm² section cables for the electrical connections to the control unit. Control unit settings Description of main settings Setting Diagram no. 10 Did you install a multizone kit? No Heating curves Max. heating flow temperature 30 C < T < 70 C Energy efficiency ratio To be defined - 5 -

8 INTRODUCTION 2.4 Diagram 3: Heat pump eus, boiler controlled by 24V On/Off contact, one heating zone EUS 8 230V 3 2 D C 9 10 G 1 12 F E V 8 RT 24V 10 NL 7 2 NL - 6 -

9 INTRODUCTION Key 1 Overheating safety (UFH shown, but can be underfloor or radiators) 2 Hydraulic module 3 Heating circuit 4 Climapro2 RF programmable wireless room thermostat 5 Systempro control unit 6 Wireless outside sensor with solar panel 7 Cll brands of boiler controlled by 24V ON/OFF contact 8 Heat pump electrical supply + protection (This must have it's own single isolation) 9 Non-return valve (recommended to prevent burner ignition triggered by thermo-siphoning) 10 Eus heat pump 11 Heat pump circuit filter (not supplied) 12 Glycol PRV discharge C D E F G Heating circuit return Heating circuit flow oiler circuit return oiler circuit flow Heat pump circuit flow Heat pump circuit return Heat pump circuit safety valve discharge pplication conditions - The Systempro control unit manages the operation of the boiler, the heat pump and the module. - The Systempro control unit manages up to 3 heating zones. - Each wireless room thermostat can control a heating zone. - oiler must have a 24V thermostat input. - The installation can be performed with a low-temperature underfloor heating (heating outlet temperature < 50 C) or low temperature radiators (heating outlet temperature < 70 C). e Use 0.75 mm² section cables for the electrical connections to the control unit. Control unit settings Description of main settings Setting Diagram no. 3 Did you install a multizone kit? No Heating curves Max. heating flow temperature 30 C < T < 70 C Energy efficiency ratio To be defined Connecting the boiler If a room thermostat is already connected to an existing boiler, remove it. Check whether the room thermostat is connected to a boiler 24V or 230V input. 24V = Connect the boiler 24V thermostat input to the "OUT1" connector of the control unit. 230V = Refer to the Diagram 13" section or install a 24V/230V converter (see below). In the case of an existing boiler without external sensor: Increase the boiler heating outlet temperature by 5 C. Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). In the case of an existing boiler with external sensor: Keep the existing boiler heating curve if the comfort of the existing installation is satisfactory. Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). Important: the setting of the control unit heating curve must be identical to that of the boiler. OK Put the installation into service. NOK Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). > If the adjustment is not available on the boiler, perform it on the thermostatic valve. > If there isn t a thermostatic valve, install a temperature control device to make this adjustment. Connection of a 24V/230V converter (not supplied) e ttention: risk of significant current draw. Check the power consumption of the component (pump, burner...) check the 230V boiler thermostat input. Legend 1 230VC / 24VDC transformer 24VDC 24VDC VC 230VC C 2 24VDC / 230VC relay C Connection to 230VC power Connection to control unit OUT1 connector Connection to the 230V thermostat connection of a boiler controlled by contact - 7 -

10 INTRODUCTION 2.5 Diagram 13: Heat pump eus, boiler controlled by 230V On/Off contact, one heating zone EUS 8 230V 3 2 D C 9 10 G 1 12 F E V 8 10 RT 230V NL 7 2 NL - 8 -

11 INTRODUCTION Key 1 Overheating safety (UFH shown, but can be underfloor or radiators) 2 Hydraulic module 3 Heating circuit 4 Climapro2 RF programmable wireless room thermostat 5 Systempro control unit 6 Wireless outside sensor with solar panel 7 ll brands of boiler controlled by 230V ON/OFF contact 8 Heat pump electrical supply + protection (This must have it's own single isolation) 9 Non-return valve (recommended to prevent burner ignition triggered by thermo-siphoning) 10 Eus heat pump 11 Heat pump circuit filter (not supplied) 12 Glycol PRV discharge C D E F G Heating circuit return Heating circuit flow oiler circuit return oiler circuit flow Heat pump circuit flow Heat pump circuit return Heat pump circuit safety valve discharge pplication conditions - The Systempro control unit manages the operation of the boiler, the heat pump and the module. - The Systempro control unit manages up to 3 heating zones. - Each wireless room thermostat can control a heating zone. - oiler must have a 230V thermostat input. Connecting the boiler If a room thermostat is already connected to an existing boiler, remove it. Check whether the room thermostat is connected to a boiler 24V or 230V input. 24V = Refer to "Diagram 3" section 230V contact = install a 230V/230V converter (see below). 230V supply = Connect the boiler 230V thermostat input to the "REL1" connector of the control unit. In the case of an existing boiler without external sensor: Increase the boiler heating outlet temperature by 5 C. Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). In the case of an existing boiler with external sensor: Keep the existing boiler heating curve if the comfort of the existing installation is satisfactory. Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). Important: the setting of the control unit heating curve must be identical to that of the boiler. - The installation can be performed with a low-temperature underfloor heating (heating outlet temperature < 50 C) or low temperature radiators (heating outlet temperature < 70 C). e Use 0.75 mm² section cables for the electrical connections to the control unit. Control unit settings Description of main settings Setting Diagram no. 13 Did you install a multizone kit? No Heating curves Max. heating flow temperature 30 C < T < 70 C Energy efficiency ratio To be defined OK Put the installation into service. NOK Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). > If the adjustment is not available on the boiler, perform it on the thermostatic valve. > If there isn t a thermostatic valve, install a temperature control device to make this adjustment. Connection of a 230V/230V converter (*) (not supplied) In the case of an On/Off boiler controlled by 1 230V contact. Legend 230VC VC / 230VC relay Connection to control unit REL1 connector 230VC Connection to the 230V thermostat connection of a boiler controlled by contact - 9 -

12 INTRODUCTION 2.6 Diagram 5: Heat pump controlled by On/Off contact, boiler eus/h2us, one heating zone EUS V 3 D C G F 13 E 12 7 N L5 L5 1 US 230V 4 N 5 NL 8 3 NL

13 INTRODUCTION Key 1 Heat pump controlled by On/Off contact 2 Heat pump circuit filter (not supplied) 3 Hydraulic module 4 Heat pump electrical supply + protection (This must have it's own single isolation) 5 Heat pump control unit 6 Wireless outside sensor with solar panel 7 Systempro control unit 8 Eus oiler 9 Climapro2 RF programmable wireless room thermostat 10 Heating circuit 11 Non-return valve (recommended to prevent burner ignition triggered by thermo-siphoning) 12 Overheating safety (UFH shown, but can be underfloor or radiators) 13 Glycol PRV discharge C D E F G Heating circuit return Heating circuit flow oiler circuit return oiler circuit flow Heat pump circuit flow Heat pump circuit return Heat pump circuit safety valve discharge pplication conditions - The Systempro control unit manages the operation of the boiler, the heat pump and the module. - The Systempro control unit manages up to 3 heating zones. - The heat pump control unit is used as a setting tool. - Each wireless room thermostat can control a heating zone. - The installation can be performed with a low-temperature underfl oor heating (heating outlet temperature < 50 C) or low temperature radiators (heating outlet temperature < 70 C). e Use 0.75 mm² section cables for the electrical connections to the control unit. Control unit settings Description of main settings Setting Diagram no. 5 Did you install a multizone kit? No Heating curves Max. heating flow temperature 30 C < T < 70 C Energy efficiency ratio To be defined Heat pump control unit settings Refer to the heat pump installation notice to access the aftersales parameters listed below. Menu Function name Setting 112 Heating curves (*) ECO heating mode (*) 1-20 C (*) Refer to the correspondence table in the Settings > Heating section

14 INTRODUCTION 2.7 Diagram 6: Heat pump controlled by On/Off contact, boiler controlled by 230V On/Off contact, one heating zone EUS V 3 D C G F 13 E 12 7 N L5 L5 1 N NL RT 230V NL 230V

15 INTRODUCTION Key 1 Heat pump controlled by On/Off contact 2 Heat pump circuit filter (not supplied) 3 Hydraulic module 4 Heat pump electrical supply + protection (This must have it's own single isolation) 5 Heat pump control unit 6 Wireless outside sensor with solar panel 7 Systempro control unit 8 ll brands of boiler controlled by 230V ON/OFF contact 9 Climapro2 RF programmable wireless room thermostat 10 Heating circuit 11 Non-return valve (recommended to prevent burner ignition triggered by thermo-siphoning) 12 Overheating safety (UFH shown, but can be underfloor or radiators) 13 Glycol PRV discharge Heating circuit return Heating circuit flow C oiler circuit return D oiler circuit flow E Heat pump circuit flow F Heat pump circuit return G Heat pump circuit safety valve discharge pplication conditions - The Systempro control unit manages the operation of the boiler, the heat pump and the module. - The Systempro control unit manages up to 3 heating zones. Connecting the boiler If a room thermostat is already connected to an existing boiler, remove it. Check whether the room thermostat is connected to a boiler 24V or 230V input. 24V = Install a 230V/24V converter (see below). 230V = Connect the boiler 230V thermostat input to the "REL1" connector of the control unit. In the case of an existing boiler without external sensor: Increase the boiler heating outlet temperature by 5 C. Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). In the case of an existing boiler with external sensor: Keep the existing boiler heating curve if the comfort of the existing installation is satisfactory. Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). Important: the setting of the control unit heating curve must be identical to that of the boiler. - The heat pump control unit is used as a setting tool. - Each wireless room thermostat can control a heating zone. - The boiler must have a 230V thermostat input. - The installation can be performed with a low-temperature underfloor heating (heating outlet temperature < 50 C) or low temperature radiators (heating outlet temperature < 70 C). e Use 0.75 mm² section cables for the electrical connections to the control unit. Control unit settings OK NOK Ensure that the heating outlet temperature does not exceed 70 C (50 C in the case of a underfloor heating). > If the adjustment is not available on the boiler, perform it on the thermostatic valve. > If there isn t a thermostatic valve, install a temperature control device to make this adjustment. Description of main settings Setting Diagram no. 6 Did you install a multizone kit? No Heating curves Max. heating flow temperature 30 C < T < 70 C Energy efficiency ratio To be defined Put the installation into service. Connection of a 230V/24V converter (not supplied) Legend 230VC 1 230VC / 24VDC relay Heat pump control unit settings Refer to the heat pump installation notice to access the aftersales parameters listed below. Menu Function name Setting 112 Heating curves (*) ECO heating mode (*) 1-20 C (*) Refer to the correspondence table in the Settings > Heating section. 1 24VDC Connection to control unit REL1 connector Connection to the 24V thermostat connection of a boiler controlled by contact

16 INTRODUCTION 2.8 Example installation with multi-zone heating option 2 zone low temperature or high temperature heating 3 zone low temperature or high temperature heating N L N L N L N L N L

17 INTRODUCTION Key 1 2 port valve "heating zone 1" 2 Heating circuit zone 1 3 Climapro2 RF programmable wireless room thermostat "zone 1" 4 2 port valve "heating zone 2" 5 Heating circuit zone 2 6 Climapro2 RF programmable wireless room thermostat "zone 2" 7 2 port valve "heating zone 3" 8 Climapro2 RF programmable wireless room thermostat "zone 3" 9 Heating circuit zone 3 10 Systempro control unit Heating circuit return Heating circuit flow pplication conditions - The Systempro control unit manages up to 3 heating zones. - Each wireless room thermostat can control a heating zone. - Zones must be same temperatures. - The installation can be performed with a low-temperature underfloor heating (heating outlet temperature < 50 C) or low temperature radiators (heating outlet temperature < 70 C). e Use 0.75 mm² section cables for the electrical connections to the control unit. 2 port valve electrical connections - When the 2 port valve is connected to REL3: Connect the neutral wire (blue) of the valve to the N of the REL3 connector. Connect the live wire (brown) of the valve to the L of the REL3 connector. Connect the earth wire (yellow/green) of the valve to the earth of the REL3 connector. Electrically insulate the red and grey wires of the valve as they are not used. - When the 2 port valve is connected to REL4 or 5: Connect the neutral wire (blue) of the valve to the N and the live wire (brown) of the valve to the L of the REL4 or 5 connector. Connect the earth wire (yellow/green) of the valve to the earth of the REL3 connector. Electrically insulate the red and grey wires of the valve as they are not used. Control unit settings Description of main settings Did you install a multizone kit? Max. heating flow temperature for the low temperature zone Max. heating flow temperature for the high temperature zone Setting Yes T < 30 C T < 70 C

18 INTRODUCTION 2.9 Example of system installation with the domestic hot water cylinder option DHW cylinder with NTC DHW cylinder with thermostat DC DC 2 E F 2 E F C C I 6 I 6 G G H H 1 1 N L N L 2.1 N L N L

19 INTRODUCTION Key 1 Systempro control unit 2 Domestic hot water cylinder 2.1 Domestic hot water NTC 2.2 Domestic hot water thermostat 3 oiler 4 Non-return valve (recommended to prevent burner ignition triggered by thermo-siphoning) 5 Domestic hot water cylinder 2 port valve 6 oiler circuit 2 port valve C D E F G H I Heating circuit return Heating circuit flow Cold water supply Domestic hot water flow oiler circuit flow oiler circuit return Heat pump circuit flow Heat pump circuit return Heat pump circuit safety valve discharge pplication conditions - The Systempro control unit manages the Domestic Hot Water cylinder (only with diagram no 10). - The maximum working pressure of the domestic hot water circuit is 10 bar. If the cold water supply pressure exceeds this, then a pressure-reducing valve must be fitted in the supply to the boiler. - In areas where the water is hard (i.e. more than 200 mg/l of calcium carbonate), it is recommended that the hot water setting is reduced and that a scale reducer is fitted, refer to the manufacturer s instructions or consult the local water company for additional advice. e Use 0.75 mm² section cables for the electrical connections to the control unit. Control unit settings Description of main settings Installation option: Domestic Hot Water cylinder The type of tank Setting On NTC sensor (1NTC) or Thermostat (1Therm)

20 INSTLLTION INSTLLTION i In the case of a multi-zone installation, fill the heating circuit using the Filling mode when commissioning the control unit. Filling mode ensures filling by automatically opening all of the circuit. Refer to the chapter Commissioning the Systempro control unit Commissioning Filling the heating circuit". 4 The control unit summarizes your installation. 5 Check the connections you made to the control unit. 3 Configuring the installation Enter the installer code 96 into the Systempro control unit. Refer to the System description section for your diagram number. 4 "Thermostat / sensor" menu 1 Choose diagram number. 2 Did you installed a multi-zone kit? 4.1 Thermostat(s) 1 Select Rmstat/sensor on the 2 Select Roomstat(s) on the 2.1 Select number of heating zones present on the system. - Z20 kit = 2 heating zones - Z11 kit = not available - Z30 kit = 3 heating zones 3 Select the area controlled by the room thermostat. 4 Via the room thermostat installer menu, select > RF > pairing. 3 Select DHW cylinder on the screen, if the option is installed. 3.1 Select the corresponding DHW cylinder. 4.2 Outdoor sensor 1 Select Rmstat/sensor on the 2 Select Outdoor sensor on the

21 INSTLLTION 3 Select Connection on the 4 Press the button on the outdoor sensor to connect. - If the connection is correct, the message "OK" appears opposite the component. - If the connection is not correct, the message "Not OK" appears opposite the component. In this case, check the connections (wired and wireless). 6 Settings This menu allows you to adjust different functions in accordance with the connected appliances and to reset all the parameters. b The outdoor sensor is operational after 24h of exposure to light and will therefore not function immediately after being unpacked Heating b The maximum heating output temperature must be adjusted in accordance with the characteristics of your installation. ON 1 Select Settings on the 2 Select Heating on the Key 1 Outdoor sensor button i The 5 Self check External T C Correction allows you to correct the temperature measured by the outdoor sensor (+/- 5 C, at intervals of 1 C - factory setting: 0). e Do not modify the cables when connected to the mains. The automatic test allows you to check EUS inputs, NTC inputs, the RF connection with the room thermostat, the outdoor sensor radio connection Max. heating flow temperature b Ensure that the heating curve setting is compatible with the installation. 3 Select max. heating flow T on the 4 djust the installation's max. heating flow temperature. i The other connections are not tested and should be visually inspected during installation or configuration modifications.. 1 Select Self check on the 2 The automatic test will start

22 INSTLLTION Heating curve The following menu allows you to select the heating curve (value adjustable between 0.2 and 4 - factory setting: 0.5), which allows you to obtain the maximum heating demand for the usual minimum outdoor temperature for the region in which the sensor is installed. Heating curve 1 2 The automatic heating curve function continually and automatically seeks the most suitable value to ensure your comfort and the efficiency of your heating system. The optimum value is obtained approximately 24 hours after the system is started. It is recommended to activate this function. 3 1 Select Htg curve settings on the 2 With utomatic htg curve activated. Key 1 Older properties with radiators 2 Standard/modern house with radiators 3 Highly insulated modern house with low temperature radiators or underfloor heating Heating flow temperature ( C) External temperature 2 With the utomatic htg curve deactivated, you must choose a heating curve. 2.2 Choose the heating curve (see curve and explanations after). 2.1 Select Htg curve setting on the Case of a heat pump controlled by On/Off contact Refer to the heat pump installation manual to access the after-sales parameters listed below. Set the heat pump heating curves complying with the correspondences with the Systempro control unit heating curves (see table below). b Incorrectly setting these parameters may significantly impact the system efficiency. - Setting of the heat pump parameter 112: Heating curve of the Systempro control unit Example: Heating curve of the heat pump Max Setting of the heat pump parameter 112: b Ensure that the heating curve setting is compatible with the installation. Heating curve of the Systempro control unit Heating curve of the heat pump Max. 12 In the case where the MODUZONE Z20 or Z30 option is installed: if the curve setting is "1.2" on the control unit, the curve setting will be "11" for heat pump parameter

23 INSTLLTION Pre heating The control unit manages the heating by anticipating the change in temperature setting between two programmed time ranges. This function allows it to reach the programmed temperature more rapidly (factory setting: active). It acts at the first morning setting change for each zone. 1 Select Pre heating on the 2 Confirm your choice. 6.2 Domestic hot water i The lower the temperature of the hot water, the more economical the heat pump. 1 Select Hot water on the 2 Set max.domestic Hot Water temperature. 6.3 Cooling Function not active for the UK

24 INSTLLTION 6.4 Energy management The energy efficiency coefficient determines the switching point between two energies (gas, electricity), in accordance with their respective costs. i The systempro makes a selection in accordance with the energy efficiency coefficient.n incorrect setting will adversely affect the system efficiency. The adjustment requires certain information that can be easily found in home owners energy bills (electricity and gas). i ccurate price information is key to the correct operation of the hybrid system. lways use the most recent energy prices from your energy provider. Depending on your installation, obtain: - he price exc VT per kwh for electricity and natural gas, Determine the energy efficiency ratio Choose the table corresponding to the type of gas used by your installation. Look for the column which corresponds to the price paid for electricity. Now, on the same table, find the price band that corresponds to the gas price paid, and where the 2 intersect determines the energy ratio. i If the values you noted down do not correspond to the values shown in the tables opposite, this means that there is probably an error. Contact the energy providers for confirmation of prices excluding VT. Please note the result (s) in the table below Energy efficiency coefficient = - the price exc VT per ton of propane gas. - the price exc VT per litre of heating oil. Enter the information and the values in the tables below. Consult the electricity bill Find and note down the unit price per kwh, excluding VT. 1 Select Energy ratio(s) on the 2 Set the Energy efficiency ratio. Unit price per kwh excluding VT: Consult the natural gas bill Find and note down the unit price per ton excluding VT. Unit price per kwh excluding VT (customer invoice): Consult the propane gas bill Find and note down the unit price per ton excluding VT. Unit price per ton excluding VT: Consult the heating oil bill Find and note down the unit price per litre excluding VT. Unit price per litre excluding VT:

25 INSTLLTION NTURL GS with electricity Price (in pence) of electricity per kwh excluding VT 8,00 to 9,00 9,10 to 10,00 10,10 to 11,00 11,10 to 12,00 12,10 to 13,00 13,10 to 14,00 14,10 to 15,00 15,10 to 16,00 price excluding VT (in pence) of natural gas in kwh 16,10 to 17,00 17,10 to 18,00 18,10 to 19,00 19,10 to 20,00 2,00 to 2,25 4,0 4,5* 5,0* 5,4* 5,9* 6,4* 6,8* 7,3* 7,8* 8,3* 8,7* 9,2* 2,26 to 2,50 3,6 4,0 4,4* 4,9* 5,3* 5,7* 6,1* 6,5* 7,0* 7,4* 7,8* 8,2* 2,51 to 2,75 3,2 3,6 4,0 4,4* 4,8* 5,2* 5,5* 5,9* 6,3* 6,7* 7,1* 7,4* 2,76 to 3,00 3,0 3,3 3,7 4,0 4,4* 4,7* 5,1* 5,4* 5,7* 6,1* 6,4* 6,8* 3,01 to 3,25 2,7 3,1 3,4 3,7 4,0 4,3* 4,6* 5,0* 5,3* 5,6* 5,9* 6,2* 3,26 to 3,50 2,5 2,8 3,1 3,4 3,7 4,0 4,3* 4,6* 4,9* 5,2* 5,5* 5,8* 3,51 to 3,75 2,3 2,6 2,9 3,2 3,5 3,7 4,0 4,3* 4,6* 4,8* 5,1* 5,4* 3,76 to 4,00 2,2 2,5 2,7 3,0 3,2 3,5 3,8 4,0 4,3* 4,5* 4,8* 5,0* 4,01 to 4,25 2,1 2,3 2,6 2,8 3,0 3,3 3,5 3,8 4,0 4,2* 4,5* 4,7* 4,26 to 4,50 1,9 2,2 2,4 2,6 2,9 3,1 3,3 3,6 3,8 4,0 4,2* 4,5* 4,51 to 4,75 1,8 2,1 2,3 2,5 2,7 2,9 3,1 3,4 3,6 3,8 4,0 4,2* 4,76 to 5,00 1,7 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 4,0 5,01 to 5,25 1,7 1,9 2,1 2,3 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 5,26 to 5,50 1,6 1,8 2,0 2,1 2,3 2,5 2,7 2,9 3,1 3,3 3,4 3,6 5,51 to 5,75 1,5 1,7 1,9 2,1 2,2 2,4 2,6 2,8 2,9 3,1 3,3 3,5 5,76 to 6,00 1,4 1,6 1,8 2,0 2,1 2,3 2,5 2,6 2,8 3,0 3,2 3,3 6,01 to 6,25 1,4 1,6 1,7 1,9 2,0 2,2 2,4 2,5 2,7 2,9 3,0 3,2 6,26 to 6,50 1,3 1,5 1,7 1,8 2,0 2,1 2,3 2,4 2,6 2,8 2,9 3,1 6,51 to 6,75 1,3 1,4 1,6 1,7 1,9 2,0 2,2 2,3 2,5 2,6 2,8 2,9 6,76 to 7,00 1,2 1,4 1,5 1,7 1,8 2,0 2,1 2,3 2,4 2,6 2,7 2,8 * Not recommended PROPNE GS with electricity Price (in pence) of electricity per kwh excluding VT 8.00 to to price excluding VT (in pence) of LPG per litre to to to to to to to to to to ,00 to 37,50 1,5 1,7 1,9 2,1 2,3 2,5 2,6 2,8 3,0 3,2 3,4 3,6 37,60 to 40,00 1,4 1,6 1,8 2,0 2,1 2,3 2,5 2,6 2,8 3,0 3,2 3,3 40,10 to 42,50 1,4 1,5 1,7 1,8 2,0 2,2 2,3 2,5 2,6 2,8 3,0 3,1 42,60 to 45,00 1,3 1,4 1,6 1,7 1,9 2,0 2,2 2,3 2,5 2,6 2,8 2,9 45,10 to 47,50 1,2 1,4 1,5 1,6 1,8 1,9 2,1 2,2 2,4 2,5 2,6 2,8 47,60 to 50,00 1,1 1,3 1,4 1,6 1,7 1,8 2,0 2,1 2,2 2,4 2,5 2,6 50,10 to 52,50 1,1 1,2 1,4 1,5 1,6 1,7 1,9 2,0 2,1 2,3 2,4 2,5 52,60 to 55,00 1,0 1,2 1,3 1,4 1,5 1,7 1,8 1,9 2,0 2,2 2,3 2,4 55,10 to 57,50 1,0 1,1 1,2 1,4 1,5 1,6 1,7 1,8 1,9 2,1 2,2 2,3 57,60 to 60,00 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,9 2,0 2,1 2,2 60,10 to 62,50 0,9 1,0 1,1 1,2 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 62,60 to 65,00 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 65,10 to 67,50 0,8 1,0 1,1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 67,60 to 70,00 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 70,10 to 72,50 0,8 0,9 1,0 1,1 1,2 1,3 1,3 1,4 1,5 1,6 1,7 1,8 72,60 to 75,00 0,8 0,9 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,7 75,10 to 77,50 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,3 1,4 1,5 1,6 1,7 77,60 to 80,00 0,7 0,8 0,9 1,0 1,1 1,1 1,2 1,3 1,4 1,5 1,6 1,6-23 -

26 INSTLLTION Heating oil with electricity Price (in pence) of electricity per kwh excluding VT 8.00 to to to to to to to to price excluding VT (in pence) of heating oil per litre to to to to ,00 to 42,50 2,1 2,3 2,6 2,8 3,0 3,3 3,5 3,8 4,0 4,3 4,5 4,7 42,60 to 45,00 1,9 2,2 2,4 2,6 2,9 3,1 3,3 3,6 3,8 4,0 4,2 4,5 45,10 to 47,50 1,8 2,1 2,3 2,5 2,7 2,9 3,1 3,4 3,6 3,8 4,0 4,2 47,60 to 50,00 1,7 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 4,0 50,10 to 52,50 1,7 1,9 2,1 2,3 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 52,60 to 55,00 1,6 1,8 2,0 2,1 2,3 2,5 2,7 2,9 3,1 3,3 3,4 3,6 55,10 to 57,50 1,5 1,7 1,9 2,1 2,2 2,4 2,6 2,8 2,9 3,1 3,3 3,5 57,60 to 60,00 1,4 1,6 1,8 2,0 2,1 2,3 2,5 2,6 2,8 3,0 3,2 3,3 60,10 to 62,50 1,4 1,6 1,7 1,9 2,0 2,2 2,4 2,5 2,7 2,9 3,0 3,2 62,60 to 65,00 1,3 1,5 1,7 1,8 2,0 2,1 2,3 2,4 2,6 2,8 2,9 3,1 65,10 to 67,50 1,3 1,4 1,6 1,7 1,9 2,0 2,2 2,3 2,5 2,6 2,8 2,9 67,60 to 70,00 1,2 1,4 1,5 1,7 1,8 2,0 2,1 2,3 2,4 2,6 2,7 2,8 70,10 to 72,50 1,2 1,3 1,5 1,6 1,8 1,9 2,0 2,2 2,3 2,5 2,6 2,7 72,60 to 75,00 1,2 1,3 1,4 1,6 1,7 1,8 2,0 2,1 2,2 2,4 2,5 2,6 75,10 to 77,50 1,1 1,3 1,4 1,5 1,6 1,8 1,9 2,0 2,2 2,3 2,4 2,6 77,60 to 80,00 1,1 1,2 1,3 1,5 1,6 1,7 1,8 2,0 2,1 2,2 2,4 2,5 80,10 to 80,25 1,0 1,2 1,3 1,4 1,5 1,7 1,8 1,9 2,0 2,2 2,3 2,4 82,60 to 85,00 1,0 1,1 1,3 1,4 1,5 1,6 1,7 1,9 2,0 2,1 2,2 2,3 6.5 Resetting parameters This feature allows you to reset the parameters of the control unit (factory setting). b The resetting of factory settings is irreversible. ny customised configuration of the control unit will be lost. 1 Select Settings reset on the 2 Confirm your choice

27 INSTLLTION 7 Commissioning This menu allows you to carry out the necessary operations on the appliances following installation. 1 Select Commissioning on the 7.3 Venting the HP circuit This function can only be activated for an eus heat pump. In the case of an On/Off heat pump, perform this operation with the parameterisation tool supplied with the heat pump. The venting of the HP circuit allows you to purge any air in the HP circuit. 1 Select Vent HP circuit on the screen 2 Start the venting procedure. 7.1 Filling the heating circuit i The Systempro control unit is used to open the valves of each zone during filling, if more than one heating zone is installed. 1 Select Fill htg circuit on the screen 2 ctivate egin filling procedure. 7.4 djustment of HP circuit flow This function can only be activated for an eus heat pump. In the case of an On/Off heat pump, adjustment of the HP circuit flow is not possible. 1 Select on the screen Glycol circuit flow. 2 Start the reading of the heat pump circuit flow rate. Refer to the boiler instructions for filling the boiler. 7.2 Venting the heating circuit Venting of the heating circuit enables the purging of any air in the heating circuit. Open the different heating circuit air vent. 1 Select ir venting on the 2 Select Vent heating circuit on the b When venting is complete, close the different heating circuit air vent

28 INSTLLTION 8 Status reports Information on heating zone This menu enables real-time access to: - the status of the appliances responding to a request (ON/OFF) - the information available from the appliances (temperature, pressure, flow,...), - register of last 5 faults recorded for each appliance (failure code and description) Information on the boiler 1 Select Status reports on the 2 Select Heating zone on the 1 Select Status reports on the 2 Select oiler on the 3 Select the zone you want to consult. 4 Consult the heating zones information. Information on the heat pump In the case of an On/Off heat pump, the forcing and information reading modes are available from the command unit supplied with the heat pump. 1 Select Status reports on the 2 Select Heat pump on the Information about the domestic hot water cylinder option i This 1 Select Status reports on the menu is only available if you have chosen the domestic hot water cylinder option. 2 Select DHW cylinder on the System information 1 Select Status reports on the 2 Select System on the

29 INSTLLTION 9 Re-check and restart Once the system is installed, check the operation of each appliance. Start the system to ensure that any adjustments operate correctly and check that the appliances operate safely. Reset the fault reports for all appliances. To do this, refer to the "Component info." section. Check the water-tightness of the appliances and eliminate any leaks. Check the entire control and safety system, settings and operation. Start the "Self check" procedure to test the system connections. 10 User information t the end of the installation, the installer must: - explain the operation of the appliances and its safety devices to the user, if necessary provide a demonstration and answer any questions; - hand over to the user all the required documentation, fill in the documents where necessary; - advise the user of the precautions necessary to prevent damage to the system, appliances and the building; - remind the user to service the appliances annually. The user shall not interfere with or adjust sealed components. ny servicing must be carried out by a competent person approved at the time by the Health and Safety Executive

30 MINTNCE MINTNCE 11 Trouble-shooting 11.1 Fault diagnosis The following checks should be performed before proceeding onto specific diagnostics: - Make sure that the electricity supply has not been interrupted and that the appliance is connected correctly. - Ensure that the isolating valves are open. - Check that all external controls are connected correctly System fault codes i The faults described in this chapter should be carried out by a qualified engineer and if needed by the fter Sales Service. Refer to the instructions for each element making up the system for their fault codes. Fault codes Description Cause Solution Failure in Ebus communication between with the boiler Failure in Ebus communication between with the heat pump Failure in Ebus communication between with the hydraulic module Heating circuit flow temperature sensor failure (open circuit) Heating circuit flow temperature sensor failure (short circuit) Heating circuit flow temperature sensor failure low temperature (open circuit) Heating circuit flow temperature sensor failure low temperature (short circuit) Domestic water tank temperature sensor failure (open circuit) Domestic water tank temperature sensor failure (short circuit) 021 Pressure too low <0.5 bar The boiler is not connected to the control unit. The cable polarity is reversed. The boiler is off. The heat pump is not connected to the control unit. The heat pump is off. The hydraulic module is not connected to the control unit. The hydraulic module is off. The sensor is defective or not properly connected to the control unit management or hydraulic module. The sensor is shorted. The sensor is defective or not properly connected to the control unit. The sensor is shorted. The sensor is defective or not properly connected to the control unit. The sensor is shorted. There is a leak in the heating circuit. The venting was not carried out correctly. Check that the boiler is connected to the control unit. Check the connection s + / - polarity. Ensure that there is no interruption to the electricity network and that the boiler is properly connected and turned on. Make sure the heat pump is connected to the control unit. Ensure that there is no interruption to the electricity network and that the heat pump is properly connected and turned on. Make sure that the hydraulic module is connected to the control unit. Ensure that there is no interruption to the electricity network and that the hydraulic module is properly connected and turned on. Check the sensor s connections. Verify that the position and the operation of the sensor are correct. Check the sensor s resistance. Check the sensor s connections. Verify that the position and the operation of the sensor are correct. Check the sensor s resistance. Check the sensor s connections. Verify that the position and the operation of the sensor are correct. Check the sensor s resistance. Check that there are no leaks. Drain the heating circuit. Remove air. Fill the installation

31 MINTNCE Fault codes Description Cause Solution Failure in communication with the zone 1 wireless room thermostat. Failure in communication with the zone 2 wireless room thermostat. Failure in communication with the zone 3 wireless room thermostat. Failure in communication with the zone 4 wireless room thermostat. Failure in communication with the zone 5 wireless room thermostat. Failure in communication with the zone 6 wireless room thermostat. Failure in communication with the wireless outdoor sensor The room thermostat is too far from the control unit. There is a problem with the batteries in room thermostat. The wireless outdoor sensor is too far from the control unit. Check the RF signal quality via the Climapro2 RF installer menu. Check the location of the thermostat. Check that the thermostat s batteries are installed in their compartment. Make sure the battery polarity is not reversed. Make sure the batteries are not dead. If so, replace them with new batteries Check the location of the outdoor sensor. Check that the sensor s power supply is correctly provided by a photovoltaic cell

32 MINTNCE 12 Servicing Consult each of the system component s instructions for more information about the corresponding maintenance operations. 1 Select System tests on the System test 2 Select System on the 13 Control unit maintenance menu Enter the installer maintenance access code (35) into the control unit Test menu This menu allows you to test the operation of all appliances and the system (boiler, HP, zone valves,) present in the installation. oiler test 3 ctivate the hydraulic module pump. i Le test de la chaudière est possible seulement si elle est raccordée en eus (schéma 10 and 5). 1 Select System tests on the 2 Select oiler on the Heating zones test i The heating zones can only be tested if you have installed multiple zone valves. Heat pump test 1 Select System tests on the 2 Select Zones on the 1 Select System tests on the 2 Select Heat pump on the 3 ctivate the multi-zone kit valve for each zone. This menu allows you to: - issue a heating demand to the heat pump (*), - activate the pump (**) - activate the fan (**) - activate the 4-way valve (**) - activate the crankcase heater (**) - activate the electrical resistance heater (**) - activate the heat exchanger s resistance heater (**) - activate the defrosting (**) (*) In the case of a heat pump controlled by an On/Off contact, perform an On/Off on the heat pump for a few seconds on the heat pump before starting the heating demand. (**) Only available with an eus heat pump

33 MINTNCE DHW cylinder test i The domestic hot water cylinder test is only possible if you have selected the domestic hot water cylinder option. 1 Select System tests on the 2 Select DHW cylinder on the 3 Perform a domestic hot water cylinder heat demand ftersales information This menu provides access to ftersales Service information. 1 Select Parameters on the 2 Select fter sales info on the 3 Display or modify the following information: - date of last access to installer menus, - the name of the company which provides the after sales service if entered, - the telephone number of the company which provides the after sales service if entered

34

35

36 _01-02/11 Subject to engineering changes GLOW-WORM Nottingham Road, elper, Derbyshire. DE56 1JT ecause of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.

System Installation. multi-zone heating

System Installation. multi-zone heating System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee

More information

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user. Climapro 2 User manual To be left with the user wireless room thermostat without receiver www.glow-worm.co.uk table of contents READ CAREFULLY BEFORE USING 1 Introducing your Climapro 2... 3 1.1 Description...

More information

Climapro 2. Installation. wireless room thermostat without receiver.

Climapro 2. Installation. wireless room thermostat without receiver. Climapro 2 Installation wireless room thermostat without receiver www.glow-worm.co.uk Table of contents INTRODUCTION 1 Instructions guidance...2 1.1 Product documentation...2 1.2 Explanation of symbols...2

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No. Ultracom 2 sxi Instructions for Use To be left with the user 12sxi G.C. No. 41-019-12 18sxi G.C. No. 41-019-13 30sxi G.C. No. 41-019-14 High Efficiency Condensing System Boilers www.glow-worm.co.uk TABLE

More information

condens Instructions for Use Ultracom 2 35 Store G.C. No

condens Instructions for Use Ultracom 2 35 Store G.C. No condens Instructions for Use Ultracom 2 35 Store G.C. No. 47-019-15 table of contents READ CAREFULLY BEFORE USING 1 Read me...3 1.1 Welcome... 3 1.2 Guarantee Pack... 3 1.3 Servicing... 3 1.4 Benchmark...

More information

Installation and Instructions for Use Outdoor Sensor

Installation and Instructions for Use Outdoor Sensor Installation and Instructions for Use Outdoor Sensor To b e l e f t w i t h t h e u s e r General Customer Service: 01773 828100 Technical Helpline: 01773 828300 General and Sales enquiries: Tel. 01773

More information

Easicom 2. Quality, Reliability, Flexibility

Easicom 2. Quality, Reliability, Flexibility Easicom 2 Quality, Reliability, Flexibility 2 EASICOM 2 EASICOM 2 Easicom 2 Quality, Reliability, Flexibility Exclusive Glow-worm boiler Developed exclusively for independent merchant branches to meet

More information

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom hxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom cxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No condens Instructions for Use Betacom 2 24 G.C. No. 47-019-16 Betacom 2 28 G.C. No. 47-019-17 table of contents READ CAREFULLY BEFORE USING 1 Read me...3 1.1 Welcome... 3 1.2 Guarantee Pack... 3 1.3 Servicing...

More information

Settings and Maintenance of the CombinAir

Settings and Maintenance of the CombinAir Atmos CombinAir Settings and Maintenance of the CombinAir Issue 13.8.10 Operation and commissioning: The control unit on the front of the CombinAir is used to adjust the settings during commissioning.

More information

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller Instructions for Use To b e l e f t w i t h t h e u s e r Clearly Solar System including Fluropro Solar Differential Controller 1 www.glow-worm.co.uk WARNINGS SAFETY The fluropro must be installed by a

More information

Easicom. Quality, reliability, flexibility

Easicom. Quality, reliability, flexibility Easicom Quality, reliability, flexibility 2 EASICOM Easicom Quality, reliability, flexibility The Easicom from Glow-worm is a high efficiency A-rated boiler which comes with a choice of outputs, models

More information

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel: 0020051423-02 10.07 British Gas 330+ High Efficiency Condensing Boiler Instructions for Use To b e l e f t w i t h t h e u s e r British Gas Service Tel: 0845 9500400 WARNING GAS LEAK OR FAULT Turn off

More information

Installation & User s Instructions

Installation & User s Instructions Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer

More information

Roth Touchline. German quality since Quick and easy user manual 1/10

Roth Touchline. German quality since Quick and easy user manual 1/10 Roth Touchline Quick and easy user manual German quality since 197 1/10 230 V Pump N N L L 230 V 230 V 2 V 2 V c/o in %H c/o out c/o in Trafo out /TB in N L eco 2V CH 1 CH 2 CH 3 CH 2V 2V 2V 2V 2V Touchline,

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

Modulating clock thermostat

Modulating clock thermostat EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode Operating instructions for the system user VIESMANN Heating system with Vitotronic 100 control unit for constant temperature mode VITODENS VITOPEND 4/2007 Please keep safe. Safety instructions For your

More information

Instructions for Use Installation and Servicing

Instructions for Use Installation and Servicing 0020004886A 18.01.05 Instructions for Use Installation and Servicing To be left with the user 12563 115-150-175-200-250-300 Unvented hot water storage cylinders Glow-worm, Nottingham Road, Belper, Derbyshire.

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons. Installation Guide: for the Warmup Tempo Digital Programmable Thermostat The world s best-selling floor heating brand Introduction The Tempo thermostat is designed to aid in the comfort of your home by

More information

IFT-RC400 IntelliFire Touch Remote Control

IFT-RC400 IntelliFire Touch Remote Control IFT-RC400 IntelliFire Touch Remote Control User Guide Introduction This user guide serves as a quick reference to the screen, functions and indicators on your IntelliFire Touch Remote control. INDICATOR

More information

Betacom 3. Technical product guide

Betacom 3. Technical product guide etacom 3 Technical product guide 2 ETOM 3 ETOM 3 3 etacom3 The etacom 3 is the Er rated, great value combi boiler from Glow-worm. Exclusive product range aters for popular heat output demands and system

More information

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk DRAWING DETAILS PART NUMBER 42011077-103 ISS R1 ECO AND DATE 0024168 08/06 ARTWORK DESCRIPTION CM921 USER GUIDE BOOKLET (UK - English) DRAWN MKTING MF BM DATE 08/06 BOOKLET DETAILS SPECIFICATION COVER

More information

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology Description The Honeywell CM921 is a wireless programmable room thermostat designed to control you heating system efficiently, providing comfortable temperatures when you are at home and energy savings

More information

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature PLEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this product and any packaging or literature in an appropriate way WHAT IS A PROGRAMMER?...an Explanation for Householders (as recommended by the

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

prestige Control Application Supplement - Type 5 MCBA WARNING

prestige Control Application Supplement - Type 5 MCBA WARNING prestige Control Application Supplement - Type 5 MCBA WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Thermostat install guide

Thermostat install guide Thermostat install guide 74_Hive Thermostat Install Guide_97mmx97mm_v3.indd 1 23/11/2015 14:0 Install Guide For Hive Active Heating the thermostat, receiver and hub are installed together so heating and

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D TWZ/CT/ODV Series Oil-Fired Hot Water Boilers (Less Tankless Heater) Installation Supplement for boilers equipped with honeywell L7248L 2012 Compliant boiler control These instructions

More information

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5 4 ±0.5 12.0 Servicing 12.2 Annual Servicing Inspection (Cont) Flame Sensing 5 ±1 10 ±1 Position Fig. 45 Spark Ignition 5. Remove the clip securing the gas feed pipe to the air/gas venturi. Disconnect the

More information

ELECTRIC BOILERS FOR CENTRAL HEATING

ELECTRIC BOILERS FOR CENTRAL HEATING ELECTRIC BOILERS FOR CENTRAL HEATING TermoMax INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations WE ARE NOT LIABLE FOR DAMAGES RESULTING FROM NON- OBSERVING

More information

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor Service Instructions Condensing gas boiler WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss of life or property damage. Refer to this manual. For assistance

More information

BOSCH CONDENS 5000W ZSB18-2A

BOSCH CONDENS 5000W ZSB18-2A 6720646195-00.1Wo HYDRONIC GAS SYSTEM BOILER 18kW BOSCH CONDENS 5000W ZSB18-2A Installation and Servicing Instructions 10 Boiler information AU/NZ 1 2 3 4 5 15 6 14 7 8 6720644743-04.1Wo 13 12 11 10 9

More information

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi cxi sxi ranges product specifications Product Range Type Model 12 15 18 24 30 38 cxi Combi 24cxi cxi Combi 30cxi cxi Combi 38cxi sxi System 18sxi sxi System 30sxi ppearance esthetic Casing dimensions (h

More information

Air Comfort. Installation instructions (English) A

Air Comfort. Installation instructions (English) A Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of

More information

Operating instructions

Operating instructions Operating instructions Migo GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation... 5 2.1 Observing

More information

Roth Touchline. German quality since User manual quick and easy guide 1/10

Roth Touchline. German quality since User manual quick and easy guide 1/10 Roth Touchline User manual quick and easy guide German quality since 97 /0 20 V Pump N N L L 20 V 20 V 2 V 2 V c/o in %H c/o out c/o in Trafo out /TB in N L eco CH CH 2 CH CH 2V 2V 2V 2V 2V 2V Touchline,

More information

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES 24-28Si II SERIES G.C. NUMBERS APPLIANCE NATURAL GAS L.P.G. 24Si II 47 311 65 47 311 66 28Si II 47 311 67 47 311 68 USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD CONTENTS Page No.

More information

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe. User Guide and Important Warranty Information Suprima 30-80 HE Condensing Central Heating Boiler Please read this document and keep it safe. It will help you out should your boiler need attention. Introduction

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Installation and servicing instructions

Installation and servicing instructions Installation and servicing instructions Programming unit RC35 For qualified professionals Please read carefully prior to commissioning and servicing 7 747 006 341-12/2006 GB Contents Contents Contents

More information

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler Wall hung, fanflue, roomsealed, high efficiency gas boiler Service manual Riva Plus HE Models G.C. ppl. No. M296.24SR/C 41-583-18 System boiler M296.28SR/C 41-583-19 System boiler Leave this manual adjacent

More information

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products Albatros2 Boiler controllers User manual Edition 2.0 Controller series B CE1U2354en 11. May 2007 RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Building Technologies HVAC Products 2/156 HVAC Products

More information

Baxi Maxflow Combi WM

Baxi Maxflow Combi WM Baxi Maxflow Combi WM Gas Fired Wall Mounted Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User

More information

Mira Platinum Wireless Controller

Mira Platinum Wireless Controller Mira Platinum Wireless Controller These instructions must be left with the user User Guide 1 CONTENTS Introduction...3 General...3 Safety Information...3 Control Layout...4 Display Symbols...5 Using the

More information

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL M/A MANUAL ESRTPRF Wireless Programmable Room Thermostat, with Delayed & Optimum Start User and Installation Instructions INDEX User Instructions What is a Programmable Room Thermostat? 1 Introduction

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No. United Kingdom en Fitting & Commissioning Instructions Outdoor Sensor Kit EcoBlue Combi and System Range Kit Part No. 7214286 (System) Kit Part No. 7213356 (Combi) These instructions should be read in

More information

Energy The power of connectivity

Energy The power of connectivity The energy you need Energy The power of connectivity Glow-worm Nottingham Road Belper Derbyshire DE56 1JT Department Telephone Email Head Office 01773 824 639 info@glow-worm.co.uk Literature 01773 596

More information

Operating instructions

Operating instructions Operating instructions Room controller 6 720 618 477-00.1RS Logamatic EMS RC35 programming unit For users Read carefully before use. 6 720 642 272 (10/2009) GB Overview of controls Overview of controls

More information

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 25Si/30Si WALL HUNG GAS-FIRED CONDENSING COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS & DOMESTIC HOT WATER THIS BOILER IS USED WITH NATURAL GAS

More information

ST9400A User Guide. Features

ST9400A User Guide. Features Features Easy to use slider and buttons combined with LoT Technology and an OK button, allows you to confi rm changes and stay in control. PLEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this

More information

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

RVL471 Heating and Domestic Hot Water Controller Basic Documentation RVL471 Heating and Domestic Hot Water Controller Basic Documentation Edition: 2.2 Controller series: C CE1P2524E 23.10.2002 Siemens Building Technologies HVAC Products 2/118 HVAC Products 23.10.2002 Contents

More information

C Note! LGI16... Burner Controls. Building Technologies

C Note! LGI16... Burner Controls. Building Technologies 7 786 Burner Controls LGI16... Burner controls For use on industrial furnaces For burners in continuous operation Without fan control and air pressure supervision Flame supervision - with QR53... / QR55,

More information

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation Document n 1408-1 ~ 11/02/2010 Control Box FR EN NL DE IT Operation manual intended for professionals and end users To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549

More information

C-Stat 17-ZW User Instructions

C-Stat 17-ZW User Instructions C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2004-28 TSG-SOLO-9/04 Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL MODULE DISPLAY -

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

The xi Range of High Efficiency Condensing Boilers. hxi Range 12-38kW

The xi Range of High Efficiency Condensing Boilers. hxi Range 12-38kW The xi Range of High Efficiency Condensing Boilers hxi Range 12-38kW Glow-worm Brand Information Here at Glow-worm we have one simple philosophy to provide you with reliable, easy to install products backed

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: Electro-Magnetic Compatibility

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Installation and Servicing. Envirosorb 2 7 / 12 / 14

Installation and Servicing. Envirosorb 2 7 / 12 / 14 Installation and Servicing Envirosorb 7 / / 4 Table of contents INTRODUCTION Instructions guidance... 3. Product documentation...3. Associated documents...3.3 Explanation of symbols...3.4 Guarantee registration...3

More information

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O HMC300 Control unit EMS plus 6 720 808 471-00.1O Operating Instructions 6 720 813 192 (2014/10) Contents Contents Key to symbols and safety instructions................3 1.1 Key to symbols...........................

More information

Greenstar 12i/24i System

Greenstar 12i/24i System USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 12i/24i System WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH

More information

MURELLE EV HE 25/55-30/55

MURELLE EV HE 25/55-30/55 UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MURELLE EV HE 25/55-30/55 User instructions 199838 Please read the Important Notice within this guide regarding

More information

Hive Active Heating. Thermostat installation guide

Hive Active Heating. Thermostat installation guide Hive Active Heating Thermostat installation guide Status Hot Central water heating Status Hot Central water heating Here s what you ll need to install Hive Active Heating A working gas central heating

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE Installation instructions For the competent person Installation instructions VRT 350 VRT 350 GB, IE Legal information Document type: Product: VRT 350 Target group: Language: Installation instructions Authorised

More information

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4 Operating instructions multimatic VRC 700f/4 AT, BE (de), CH (de), DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 2810 info@vaillant.de

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

Energy. The power of connectivity

Energy. The power of connectivity Energy The power of connectivity 2 ENERGY ENERGY 3 Energy at the heart of your business... Combi The Energy boiler range from Glow-worm Regular heat only System By choosing Energy, you re actually investing

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WH THE USER ECOMFORT PLUS 25 HE User instructions All descriptions and illustrations provided in this manual have been carefully prepared but we reserve the right to make

More information

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit Operating instructions for the system user VIESMANN With constant temperature or weather-compensated control unit VITODENS 050-W 9/2014 Please keep safe. Safety instructions For your safety Please follow

More information

ProCon Boiler Controller Commissioning Quick Reference Guide

ProCon Boiler Controller Commissioning Quick Reference Guide ProCon Boiler Controller Commissioning Quick Reference Guide This sheet is intended as a quick reference guide and should be read in conjunction with the operating and maintenance manual for the boiler

More information

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS A it KIT UNITÀ AMBIENTE E INTERFACCIA A LED PER IL CONTROLLO DELLA TEMPERATURA AMBIENTE DEL LOCALE en KIT ROOM UNIT AND LED INTERFACE ROOM TEMPERATURE CONTROL ACCESSORY de RAUMGERÄT UND LED-SCHNITTSTELLE

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI For the owner Operating manual ecotec plus 937 Gas condensing storage combination boiler GB VUI Contents Appliance characteristics Recommended accessories Contents Appliance characteristics... Recommended

More information

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE MAX SYSTEM USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products Albatros2 Boiler controller User Manual Edition 3.0 Controller series B CE1U2354en 23. August 2007 RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Building Technologies HVAC Products 2/180 HVAC

More information

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus 24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-32/40 kw Warmhaus wall-hung gas combi boilers Priwa and PriwaPlus,

More information

Daikin Altherma Hybrid User Guide

Daikin Altherma Hybrid User Guide Daikin Altherma Hybrid User Guide Your new Daikin Altherma hybrid heat pump In this guide you will find information and guidelines that will allow you to run your Daikin Altherma hybrid heat pump system

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products Albatros 2 Zone controller User Manual RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Edition 3.0 @@@@ CE1U2353en 02.06.2009 Building Technologies HVAC Products 2/135 HVAC Products 02.06.2009 Contents

More information