1 Before using your air conditioner, please read this manual carefully and keep it for future reference. - INVERTER SPLIT TYPE ROOM AIR CONDITIONER SERIES Please read this installation manual completely before installing the product. If the power cord is damaged, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring Standards by authorised personnel only. Contact an authorised service technician for repair, maintenance or installation of this unit.

2 CONTENTS SAFETY PRECAUTIONS Warning...2 Caution...2 INSTALLATION INSTRUCTIONS Selecting installation place...3 Accessories Indoor unit installation...8 Outdoor unit installation...9 REFRIGERANT PIPE CONNECTION Refrigerant pipe connection...10 ELECTRICAL WORK Electrical work TEST RUNNING Test running CAUTION Contact an authorised service technician for repair or maintenance of this unit. Contact the authinstaller for installation of this unit. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the air conditioner. If the power cord is to be replaced, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring standards by authorised personnel only. 1

3 SAFETY PRECAUTIONS Read the follow SAFETY PRECAUTIONS carefully before installation. Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seri ousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. The items to be followed are classified by the symbols: Symbol will background white denotes item that is PROHIBITED from doing. WARNING 1) Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2) Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall, water leakage, electrical shock or fire., 4) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5) For electrical work, follow the local national wiring standard, regulation and this installation instructions. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8) When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury. 9) Do not modify the length of the power supply cord or use of extension cord, and do not share the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock. CAUTION 1) This equipment must be earthed and installed with earth leakage current breaker. It may cause electrical shock if grounding is not perfect. 2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 2

4 INSTALLATION INSTRUCTIONS Selecting installation place Read completely, then follow step by step. Indoor unit Do not expose the indoor unit to heat or steam. Select a place where there are no obstacles in front or around the unit. Make sure that condensation drainage can be conveniently routed away. Do not install near a doorway. Ensure that the space on the left and right of the unit is more than 12cm/4.72in. Fig.1 Use a stud finder to locate studs to prevent unnecessary damage to the wall. The indoor unit should be installed on the wall at a height of 2.3m/7.55ft or more from the floor. The indoor unit should be installed allowing a minimum clearance of 15cm/5.9in from the ceiling. Any variations in pipe length will/may require adjustment to refrigerant charge. There should not be any direct sunlight. Otherwise, the sun will fade the plastic cabinet and affect its appearance. If unavoidable, sunlight prevention should be taken into consideration. Outdoor unit If an awning is built over the outdoor unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted. Ensure that the clearance around the back of the unit is more than 30cm/11.81in and left side is more than 30cm/11.81in. The front of the unit should have more than 200cm/78.74in of clearance and the connection side (right side) should have more than 60cm/23.62in of clearance. Do not place animals and plants in the path of the air inlet or outlet. Take the air conditioner weight into account and select a place where noise and vibration will not be an issue. Select a place so that the warm air and noise from the air conditioner do not disturb neighbors. Rooftop installation: If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting. If the outdoor unit is installed on roof structures or external walls, this may result in excessive noise and vibration, and may also be classed as a non serviceable installation. Tools needed for installation: Level gauge Screwdriver Electric drill,hole core drill (φ90mm/3.54in) Flaring tool set Specified torque wrenches: 1.8kgf.m, 4.2kgf.m, 5.5kgf.m, 6.6kgf.m (different depending on model No.) Spanner (half union) 3 More than 30cm/11.81in More than 12cm/4.72in More than 200cm/78.74in More than 15cm/5.9in (to the ceiling) More than 2.3m/7.55ft (from the floor) More than30cm/11.81in Fig.2 Hexagonal wrench (4mm/0.157in) Gas-leak detector Vacuum pump Gauge manifold Users manual Thermometer Multimeter Pipe cutter Measuring tape More than 12cm/4.72in More than 60cm/23.62in

5 ON/OFF MODE FAN SLEEP TURBO TEMP SHORT CUT TIMER ON TIMER OFF SWING DIRECT LED Accessories Remote controller Self-tapping Screw B ST2.9X10 INSTALLATION INSTRUCTIONS Number 1 Name of Accessories Installation Plate Q ty 1 2 Clip Anchor 5-8(depending on models) 3 Self-tapping Screw A ST3.9X25 5-8(depending on models) Seal(For cooling & heating models only) Drain Joint(For cooling & heating models only) Remote controller holder Quick connecting refrigerant pipe Optional parts Air freshening filter(used to install on Air filter) Sound deadening pads(used to wrap up the quick connectors) Note: Except the above parts provided, the other parts needed during installation you must purchase (depending on models) 2 >12cm/4.72in 3 2 >15cm/5.9in 1 >12cm/4.72in CAUTION Use a stud finder to locate studs to prevent unnecessary damage to the wall. Two of the A, B and C directions should be free from obstructions. This illustration is for explanation purposes only. Copper lines must be insulated independently. Air Filter >2.3m/7.54ft Quick connecting refrigerant pipe A 30cm above Air Outlet 60cm above 30cm above B 200cm above 60cm above C Remote Controller 6 7 Mounting screw B ST2.9x10-C-H 8 Remote controller holder Fig.3 4

6 / /12.4 B B 25/0.98 INSTALLATION INSTRUCTIONS Indoor unit installation 1. Fit the Installation Plate 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. 2. If the wall is made of brick, concrete or the like, drill five or eight 5mm/0.197in diameter holes in the wall. Insert Clip anchor for appropriate mounting screws. 3. Fit the installation plate on the wall with eight or five type A screws. 120mm/4.72in or more to wall C Correct orientation of Installation Plate Fig.4 150mm/5.91in or more to ceiling D Indoor unit outline 120mm/4.72in or more to wall Note: Fit the Installation Plate and drill holes in the wall according to the wall structure and corresponding mounting points on the installation plate. (Dimensions are in mm/in unless otherwise stated) Left rear side refrigerant pipe hole φ90/3.54in 120mm/4.72in or more to wall Left rear side refrigerant pipe hole φ90/3.54in 150mm/5.91in or more to ceiling D Right rear side refrigerant pipe hole φ90/3.54in 9000Btu/h models(a:680/26.77, B:255/10.04, C:170/6.69, D:92/3.62) 12000Btu/h models(a:770/30.31, B:255/10.04, C:170/6.69, D:95/3.74) 55/ /2.17 C A A Indoor unit outline 120mm/4.72in or more to wall Right rear side refrigerant pipe hole φ90/ Btu/h models(a:905/35.63, B:275/10.83, C:80/3.15, D:100/3.94) 55/ / mm/5.91in or more to ceiling Indoor unit outline 293/11.54 Installation plate 163/ mm/4.72in or more to wall 21.5/ mm/4.72in or more to wall Left rear side refrigerant pipe hole φ90/3.54in 1030/ Btu/h models Right rear side refrigerant pipe hole φ90/ mm/5.91in or more to ceiling 1450/ mm/4.72in or more to wall 35/1.38 Left rear side refrigerant pipe hole φ90/3.54in 55/2.17 >30000Btu/h models Fig.5 5

7 INSTALLATION INSTRUCTIONS 2. Drill a hole in the wall 1. Determine hole positions according to the diagram detailed in Fig.5. Drill one (1) hole (φ90mm/3.54in) slanting slightly to outdoor side. 2. Always use wall hole conduit when drilling metal grid, metal plate or the like. Indoor Wall Outdoor 5-7mm / in 3. Drainage Installation Fig.6 Drainage 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated in Fig When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. 4. Connecting the refrigerant pipes 4.1 Tools needed -You will require the following tools to carry out this installation work correctly: 1x open-ended spanner, 19 mm/0.75in 1x open-ended spanner, 22 mm/0.87in 1x open-ended spanner, 24 mm/0.95in 1x Allen key, 5 mm/0.2in 1x Philips screwdriver 1x leak detection spray or alternatively soap suds (water/detergent mix) Do not form a rise Fig.7 Do not put the hose end into water or any container 4.2 Important information Follow the detailed instructions for connecting the refrigerant pipes to the indoor unit and outdoor unit. We can only provide a warranty if the lines are installed correctly as described in the instructions. Do not remove the sealing caps and stoppers until immediately before you install the lines. To prevent leaks, ensure that the quick-release screw connections are absolutely free of dirt. Moisture or foreign bodies will adversely affect the function of the quick-release connectors, leading to a risk of refrigerant loss (not covered by the warranty). Only install refrigerant lines outdoors in dry weather. The refrigerant lines must not be installed and then plastered over. Please make sure that refrigerant is never allowed to enter the environment. Improper handling of refrigerant may be harmful to health. Always wear work gloves and goggles when handling refrigerant. Refrigerant pipe Connectors(both ends): Fig.8 NOTE: To distinguish the connectors to be connected to the indoor unit and outdoor unit, the connectors of the refrigerant pipe has been labelled A, B, C and D. Ensure the marks on the connectors are the same,, to the indoor s and outdoor s respectively during connection. 6

8 INSTALLATION INSTRUCTIONS Do not smoke during the installation work. The equipment must never be operated without the refrigerant lines connected, otherwise the equipment will be damaged immediately. The screw connections may only be tightened using the appropriate open-ended spanner. Remember that if they are tightened with too little torque they will leak but if they are tightened with too much torque, the screw connections may suffer damage. If you should not be confident about connecting the refrigerant line connectors yourself, it is imperative that you contact your customer service team or a refrigeration contractor. Important! The EQ valves are only designed for one-time installation. Their seal can not be guaranteed if they are installed on more than one occasion. This will also void the warranty. A Fig.9 B 4.3 Connecting the refrigerant pipes to indoor unit 1. Do not remove the plastic seals from the indoor equiopment and the appropriate refrigerant pipe until immediately before you connect them. 2. Align the refrigerant pipes correctly, make sure the dimensions of the connecting refrigerant pipe are the same. Place the screw connector on the refrigerant pipes just on to the thread on the indoor equipment and tighten the first few threads by hand. See Fig.9. IMPORTANT: Before you continue, it is essential that you read the following instructions carefully.,, 3. Hold the points marked A using a 22mm/0.87in openended spanner and turn the nuts only at the points,, marked B using a 24mm/0.95in open-ended spanner. See Fig.10a & 10b. 4. Ensure that the screw connectors do not skew as you tighten them and work quickly. IMPORTANT: Since the coupling works with tapping rings, it may leak if you undo and reconnect the pipes. This will also void the warranty.,,,, 5. After finishing the connection, first wrap up the quick connectors with the sound deadening pads(packed with accessories) solidly and tightly as shown in Fig.11, then use the tape to wrap the refrigerant pipe and connecting cable together. See Fig.12. NOTE: For aesthetic reason, the quick connector parts are recommended to be placed outside of room. 7 Fig.10a Fig.10b Fig.11 Fig.12

9 ... INSTALLATION INSTRUCTIONS Note: Route the package of pipes/hoses in the direction of (rear)right or (rear)left. See Fig Both sides drainage structure is standard. For both sides drainage structure, it can be choosen for right, left or both sides drainage connection. If choosing both sides drainage connection, another proper drain hose is needed as there is only one drain hose offered by factory. If choosing one side drainage connection, make sure the drain hole on the other side is well plugged. For 9k/12k models, if choosing left-hand or left-back piping,please choosing left side drainage connection. The connection of the drain hose is supposed to be done by qualified installer in case of water leakage. 2. Bundle the tubing, connecting cable with tape securely, evenly as shown in Fig.14. Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room. Do not put anything else in the box. CAUTION: Do not allow the piping to let out from the back of the indoor unit. Be careful not to let the drain hose slack. Heat insulated both of the auxiliary piping. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Never intercross nor intertwist the power wire with any other wiring. Run the drain hose sloped downward to drain out the condensed water smoothly. 5. Indoor unit installation 1. Feed the package of pipes/hoses through the hole in the wall. 2. Hook the indoor unit onto the upper portion of the installation plate.(engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right. 3. The female half can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots. Drain hose Fig.13 Indoor unit Connective cable Fig Fig.14 Rubber plug Ponding box Pipe room Connective pipe Wrapping belt 8

10 INSTALLATION INSTRUCTIONS Outdoor unit installation 1. Outdoor installation precaution Select the location for installation(follow the previous notes on selecting the installation place). If the outdoor unit is higher thanthe indoor unit, make sure that a curve is made in the refrigerant pipe which is lower than the bottom edge of the indoor unit. See Fig.16. In the case that the installation place is exposed to strong wind such as a seaside, make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates, Fig.17. If need suspending installation, the installation bracket should accord with technique requirement in the installation bracket diagram. The installation wall should be solid brick, concrete or the same intensity construction, or actions to reinforce, damping supporting should be taken. The connection between bracket and wall, bracket and the air conditioner should be firm, stable and reliable. Be sure there is no obstacle which block radiating air. 2. Settlement of outdoor unit Anchor the outdoor unit with a bolt and nutφ10 or φ8 tightly and horizontally on a concrete or rigid mount. Outdoor unit dimension mm/in(wxhxd) A(mm/in) B(mm/in) 760(29.92)x590(23.23)x285(11.22) 820(32.28)x595(23.43)x330(12.99) 780(30.71)x540(21.26)x250(9.84) 660(25.98)x242(9.52)x540(21.26) 840(33.07)x700(27.56)x320(12.6) 990(38.98)x965(37.99)x345(13.58) Mounting dimensions 530(20.87) 290(11.42) 523(20.59) 340(13.39) 549(21.61) 458(18.03) 560(22.05) 624(24.57) 276(10.87) 276(10.87) 335(13.19) 366(14.41) Outdoor unit Refrigerant pipe Indoor unit D Air inlet Strong wind Fig.16 Fig.17 W A Fig.18 Curve Air inlet Air outlet B Drain joint installation NOTE: The drain joint is slightly different according to the different outdoor unit. For the drain joint with the seal(fig.19 (A)), first fit the seal onto the drain joint, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble them. To install drain joint as shown in Fig.19 (B), insert the drain joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound. Connecting the drain joint with an extension drain hose (Locally purchased), in case of the water draining off the outdoor unit during the heating mode. 9 Seal Drain joint Base pan hole of outdoor unit Seal Drain pipe (A) Fig.19 (B)

11 REFRIGERANT PIPE CONNECTION 4. Connecting the refrigerant pipe to outdoor unit CAUTION: For your safety, always wear goggles and work gloves when connecting the pipes. NOTE: To distinguish the connectors to be connected to the indoor unit and outdoor unit, the connectors of the refrigerant pipe has been labelled A, B, C and D. Ensure the marks, on the, connector are the same to the indoor s and outdoor s respectively during connection. 1. First remove the water tray on the outdoor unit as shown in Fig Do not remove the plastic seals from the outdoor unit and the appropriate refrigerant pipes until immediately before you connect them, Fig Align the refrigerant pipes correctly so that they line up with the valves and are not stressed. Place the screw connector on the refrigerant line just on to the thread on the outdoor unit and tighten the first few threads by hand, Fig.22. NOTE: The refrigerant pipes must be connected to the valves on the outdoor unit with as little stress as possible. IMPORTANT: Before you continue, it is essential that you read the following instructions carefully. 4. Now tighten the bottom screw connector first and then the top screw connector using the open-ended spanner. Hold the points marked A using a 22mm/0.87in open-ended spanner and turn the nuts only at the points marked B using a 24mm/0.95in open-ended spanner, see Fig.23. Ensure that the screw connectors do not skew as you tighten them and work quickly. See the next page for the proper torque. IMPORTANT: Since the coupling works with tapping rings, it may leak if you undo and reconnect the pipes. This will also void the warranty. A Fig.20 Fig.21 Fig.22 B A B Fig.23 10

12 REFRIGERANT PIPE CONNECTION Coupling size (last 2 part numbers) Pound-force foot(1bf-ft) Newton meter(n-m) Kilogram-force meter(kgf-m) -06(9.5mm/3/8 dash size) (12.7mm/1/2 dash size) (19.1mm/3/8 dash size) (25.4mm/1 dash size) After completing steps 1-4, check that all the connections are sealed correctly using leak detection spray or soap suds. If any bubbles form, the system has a leak and the screw connectors must be retightened using an open-ended spanner. 5. Now remove the cover on the top valve using a 19 mm open-ended spanner. Open the valve by turning it counter-clockwise as far as it will go using a 5 mm Allen key. The valve is now open. If the valve is not opened fully, the system may malfunction and suffer damage. Screw the cover back on to the top valve and tighten it well to ensure that it is properly sealed. See Fig Now remove the cover on the bottom valve using a 19 mm open-ended spanner. Open the valve by turning it counter-clockwise as far as it will go using a 5 mm Allen key. The valve is now open. If the valve is not opened fully, the system may malfunction and suffer damage. Screw the cover back on to the bottom valve and tighten it well to ensure that it is properly sealed. See Fig.25. Important! The conical ring on the valve has an important sealing function together with the sealing seat in the caps. Ensure that you do not damage the cone and that you keep the cap free of dirt and dust. Fig After completing steps 1-6, check that all the connections are sealed correctly using leak detection spray or soap suds. If any bubbles form, the system has a leak and the screw connectors must be retightened using an open- ended spanner. 8. Start the equipment so that the operating pressures build up inside it. Check all the connectors again for signs of leaks a) during cooling mode b) in heating mode. If any bubbles form, the system has a leak and the screw connectors must be retightened using an open-ended spanner. Fig.25 11

13 CAUTION CAUTION Electrical work Electric safety regulations for the initial Installation 1. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should be in the range of 90%~110%of rated voltage. 3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit should be installed in power circuit. Ensure the air conditioner is grounded well. 4. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air conditioner in a wet room such as a bathroom or laundry room. 5. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage current that may exceed 10mA, the residual current device(rcd) having a rated residual operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. 6. For the unit adopts auxiliary electric heater, keep at least 1 meter away from the nearest combustible materials. 7. According to the attached Electrical Connection Diagram located on the panel of the indoor & outdoor unit to connect the wire. All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians. 8. An individual branch circuit and single receptacle used only for this air conditioner must be available. See the following table for suggested wire sizes and fuse specifications: Suggest Minimum Wire Size (AWG:American Wire Gage): NOTE: Appliance Amps AWG Wire Size The wire size of power supply cord and interconnected wire and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit. Please refer to the nameplate before selecting the wire size, fuse or switch The controller of the air conditioner designed with a fuse protection function under abnormal conditions, the specifications of the fuse have 40 8 printed on the circuit board, such as: T3.15A/250VAC, T5A/250VAC, etc. 12 ELECTRICAL WORK CAUTION CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3) Specification of power source. 4) Confirm that electrical capacity is sufficient. 5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6) Confirm that the cable thickness is as specified in the power source specification. 7) Always install an earth leakage circuit breaker in a wet or moist area. 8) The following would be caused by voltage drop. Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload.

14 ELECTRICAL WORK Connect the cable between indoor unit and outdoor unit NOTE: Before performing any electrical work, turn off the main power to the system. 1. The connection cables of indoor and outdoor units have been connected to the terminals on the control board except the grounding wire(y/g), only white plug connectors exposed. See Fig Remove the control cover from the outdoor unit by loosening the screw. 3. Hold the indoor male plug and insert it into the female plug of the outdoor unit until it fixed with a clicking sound. Secure the cable onto the control board with the cord clamp. See Fig Connect the grounding wire to the terminal on the control board individually. 5. The electrical connection has finished now. Cover Fig.26 Front Panel Electronic box cover Terminal block of indoor unit L N S L N S or L1 L2 Cord clamp G L1 L2 S S G Screw To outdoor unit To outdoor unit 115V~60Hz V~60Hz Terminal block of outdoor unit 1(L) 2(N) S L N L1 L2 S L1 L2 G G G G To power supply To power supply To indoor unit To indoor unit 115V~60Hz V~60Hz Fig.27 13

15 Test running TEST RUNNING Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. Check that all tubing and wiring have been properly connected. Check that the gas and liquid side service valves are fully open. 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. 2. Use the MODE button to select COOL, HEAT, AUTO and FAN to check if all the functions works well. O 3. When the amient temperature is too low(lower than 17 C/62 F), the unit cannot be controlled by the remote controller to run at cooling mode, manual operation can be taken. Manual operation is used only when the remote controller is disable or maintenance necessary. Hold the panel sides and lift the panel up to an angle until it remains fixed with a clicking sound. Press the Manual control button to select the AUTO or COOL, the unit will operate under Forced AUTO or COOL mode(see User Manual for details). 4. The test operation should last about 30 minutes. Manual control button AUTO/COOL Fig.28 14

16 The Klimaire logo is a registered Trademark of Klimaire Products inc. Copyright 2010 Klimaire Products Inc NW 89 Place, Doral, FL USA Tel: (305) Fax (305) sales@klimaire.com The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

DUCTLESS MINI-SPLIT INSTALLATION MANUAL FOR MODELS: 1PAMSHQCW PAMSHQCW12-15 COMFORT...BUILT TO LAST 12,000 BTU / 15 SEER QUICK CONNECT

DUCTLESS MINI-SPLIT INSTALLATION MANUAL FOR MODELS: 1PAMSHQCW PAMSHQCW12-15 COMFORT...BUILT TO LAST 12,000 BTU / 15 SEER QUICK CONNECT COMFORT...BUILT TO LAST 12,000 BTU / 15 SEER QUICK CONNECT DUCTLESS MINI-SPLIT With 11,500 BTU Heat Pump INSTALLATION MANUAL FOR MODELS: 1PAMSHQCW12-15 Indoor Wall Unit 1PAMSHQCW12-15 Outdoor Condenser

More information

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump COMFORT...BUILT TO LAST 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump INSTALLATION MANUAL INDOOR UNIT: 1PAMSH09-SZW-14.5 1PAMSH09-SZW-15 1PAMSH12-SZW-15 1PAMSH18-SZW-15

More information

SPLIT-TYPE ROOM AIR CONDITIONER

SPLIT-TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT-TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing the

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL (Inverter Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT -TYPE ROOM AIR CONDITIONER iqool9 iqool2 iqool8 iqool24 Please read this installation manual

More information

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Forest Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36 QUICK CONNECT DUCTLESS MINI-SPLIT SYSTEM INSTALLATION MANUAL FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36 Before using your air conditioner, please read this manual carefully and keep it for

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. PLIT -TYPE ROOM AIR CONDITIONER The design and specifications are subject to change without prior

More information

INVENTER SPLIT -TYPE ROOM AIR CONDITIONER

INVENTER SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference INVENTER SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

Installation Manual. All Model Numbers SERIES SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. All Model Numbers SERIES SPLIT-TYPE ROOM AIR CONDITIONER SERIES SPLIT-TYPE ROOM AIR CONDITIONER Manual All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for

More information

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series Please read this manual carefully before installation and keep it for future reference. CONTENTS Installation Manual DIY Series The design and specifications are subject to change without prior notice.

More information

Choosing the installation site. Installation. 07 Choosing the installation site

Choosing the installation site. Installation. 07 Choosing the installation site Installation Installation warnings: 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state, and national electrical codes and by qualified,

More information

R410A SPLIT SERIES DC INVERTER

R410A SPLIT SERIES DC INVERTER R410A SPLIT SERIES DC INVERTER Models ECO906SD ECO908SD ECO1206SD ECO1208SD ECO1806SD Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER efore using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT -TYPE ROOM IR CONDITIONER The design and specifications are subject to change without prior notice

More information

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual Presents SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual 9k,12k 18k 24k, 30k, 36k ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 Phone: 800.325.5479

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER efore using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT -TYPE ROOM IR CONDITIONER The design and specifications are subject to change without prior notice

More information

INVERTER SPLIT - TYPE ROOM AIR CONDITIONER

INVERTER SPLIT - TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT - TYPE ROOM AIR CONDITIONER Please read this installation manual completely before

More information

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST COMFORT...BUILT TO LAST SINGLE ZONE DUCTLESS MINI-SPLIT INSTALLATION MANUAL 2PAMS SERIES Before using your air conditioner please read this manual carefully and keep it for future reference, along with

More information

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Please read this user manual first! Dear Customer, Thank you for preferring a Beko product.

More information

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents. All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567 2020323B2335 (June

More information

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1 Installation and Operation Manual SVH Series Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1 www.marsdelivers.com Table of Contents Installation Manual

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP WAS / WYS Series WAS: Cooling Only Version WYS: Cooling and Heating Version Inverter+ and Inverter++ Models For 9,000-36,000 BTU/hr Systems Installation

More information

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF Installation Manual DVC/DVH Series Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF B-DVC/DVH 09SF B-DVC/DVH 12SF B-DVC/DVH 18SF B-DVC/DVH 24SF www.marsdelivers.com

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

More information

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1 Wall Mounted AIR CONDITIONER Installation Manual KS Series KS09 KS12 KS18 KS24 KS28 J3387_Kaden_Installer_Manual_050917.indd 1 5/09/2017 9:07 AM J3387_Kaden_Installer_Manual_050917.indd 2 5/09/2017 9:07

More information

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL CONTENTS SAFETY PRECAUTIONS Warning... Caution... INSTALLATION INSTRUCTIONS Accessories...;...3 Selecting installation place...4 PIPE CONNECTION

More information

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Aurora Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to

More information

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual KSIF Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to

More information

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual SYSPLIT WALL FLEXI Series IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

Horizontal/Side Discharge Condensing Units

Horizontal/Side Discharge Condensing Units INSTALLATION, OPERATION & MAINTENANCE MANUAL Horizontal/Side Discharge Condensing Units Models CMA12SD-0 CMA18SD-1 CMA24SD-1 CMA30SD-1 CMA36SD-1 CMA48SD-1 517.787.2100 www.marsdelivers.com Horizontal/Side

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Aurora Series All Model Numbers 2925CP65 292CP565 2925CP66 292CP566 2925CP67 292CP567 2925CP68 292CP568 CS78421-548-754 IMPORTANT NOTE: Read this manual

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

Notices for installation

Notices for installation Notices for installation Important Notices Before installing, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may

More information

Installation Manual Forest Series All Model Numbers

Installation Manual Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Forest Series All Model Numbers CS78421-548-754 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Oasis Series All Model Numbers CS78421-548-754 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

Split Air Conditioner

Split Air Conditioner Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWC09AB-D3DNA2D GWC12AB-D3DNA2D GWC18AC-D3DNA2D GWC24AC-D3DNA2D GWH09AB-D3DNA2D GWH12AB-D3DNA2D GWH18AC-D3DNA2D

More information

INSTALLATION GUIDE MODEL: ACDC12(B)

INSTALLATION GUIDE MODEL: ACDC12(B) INSTALLATION GUIDE MODEL: ACDC12(B) Version 1.0 ACDC12B Solar Air Conditioner Heat Pump Installation Manual Before installing or using your solar air conditioner, please print and read this manual carefully

More information

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER Please read this installation manual completely before

More information

VMH09/12/18/24 SU Series

VMH09/12/18/24 SU Series Installation and Operation Manual VMH09/12/18/24 SU Series Inverter Single Zone Ductless Mini-Split 517.787.2100 www.marsdelivers.com www.heatcontroller.com TABLE OF CONTENTS Safety Precautions Warnings

More information

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units Installation and Operation Manual CMA12SB-0 Series Horizontal/Side Discharge Condensing Units 517.787.2100 www.marsdelivers.com www.heatcontroller.com Heat Controller CONTENTS PAGE 1. PRES... 1 2. INSTALLATION

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

Split Air Conditioner

Split Air Conditioner Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD

More information

R32 AIR CONDITIONER HIGH WALL MOUNTED INSTALLATION MANUAL. English DC INVERTER IMPORTANT NOTE: Indoor unit high wall mounted HRD

R32 AIR CONDITIONER HIGH WALL MOUNTED INSTALLATION MANUAL. English DC INVERTER IMPORTANT NOTE: Indoor unit high wall mounted HRD INSTALLATION MANUAL ENGLISH AIR CONDITIONER HIGH WALL MOUNTED DC INVERTER R32 English Indoor unit high wall mounted HRD IMPORTANT NOTE: Read this manual carefully before installing or operating your new

More information

UltraV Series Outdoor Units

UltraV Series Outdoor Units INSTALLATION MANUAL UltraV Series Outdoor Units Models A-VMH18DU-1 A-VMH28TU-1 A-VMH36QU-1 517.787.2100 www.marsdelivers.com Table of Contents Installation Manual 1 2 3 4 5 Accessories... 4 Safety Precautions...

More information

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS MULTI TYPE ROOM IR CONDITIONERS INSTLLTION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed

More information

Installation Instructions

Installation Instructions 40MAQ / 38MAQ 619PB / 538PR High---Wall Ductless Split System Sizes 09 to 30 Installation Instructions TABLE OF CONTENTS PAGE PARTS LIST... 2 SAFETY CONSIDERATIONS... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS...

More information

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make

More information

AIR CONDITIONER CONSOLE

AIR CONDITIONER CONSOLE Installation manual ENGLISH AIR CONDITIONER CONSOLE English Indoor unit console type IT IS MANDATORY TO CUT OFF POWER SUPPLY BEFORE STARTING TO WORK IN THE ELECTRIC CASING BOXES. GENERAL RECOMMENDATIONS

More information

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH

More information

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S Split Air Conditioner Model: WMI09MH16S WMI12MH16S WMI18MH16S Thank you for choosing our product. For proper operation, please read and keep this manual carefully. Content Operation Notices Precautions...1

More information

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11 MWM36Y3J MRM36Y3J 11 Content Operation Notices Precautions...1 Parts name...2 Screen Operation Guide Buttons on remote controller...3 Introduction for icons on display screen...3 Introduction for buttons

More information

Installation Manual. Floor-Standing Type FLOOR-STANDING TYPE AIR CONDITIONER

Installation Manual. Floor-Standing Type FLOOR-STANDING TYPE AIR CONDITIONER FLOOR-STANDING TYPE AIR CONDITIONER Installation Manual Floor-Standing Type IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram. Table of Contents Installation Manual 1 2 3 Accessories...04 Safety Precautions...05 Installation Overview...06 4 Installation Diagram...07 5 Specifications...08 6 Outdoor Unit Installation... 09 a. Outdoor

More information

Installation Manual. Εγχειρίδιο Εγκατάστασης ΚΛΙ ΜΑ ΤΙ ΣΤ ΙΚ Α ΣΥ Η Μ Α. Wall Mounted Air-Conditioning Unit. Επιτοίχια Μονάδα Κλιματισμού

Installation Manual. Εγχειρίδιο Εγκατάστασης ΚΛΙ ΜΑ ΤΙ ΣΤ ΙΚ Α ΣΥ Η Μ Α. Wall Mounted Air-Conditioning Unit. Επιτοίχια Μονάδα Κλιματισμού ΚΛΙ ΜΑ ΤΙ ΣΤ ΙΚ Α O1MVI-09WFR/O1MVO-09 O1MVI-12WFR/O1MVO-12 O1MVI-18WFR/O1MVO-18 Μ Α Τ Α O1MVI-24WFR/O1MVO-24 ΣΥ ΣΤ Η Wall Mounted Air-Conditioning Unit Installation Manual Επιτοίχια Μονάδα Κλιματισμού

More information

Installation Manual ENE ACDC12. Solar Mini-Split Heat Pump System

Installation Manual ENE ACDC12. Solar Mini-Split Heat Pump System Installation Manual ENE ACDC12 Solar Mini-Split Heat Pump System Please read this installation manual completely before installing the product. If the power cord is damaged, replacement must be performed

More information

GENERAL INFORMATION CONTENTS

GENERAL INFORMATION CONTENTS AMTCM4H4R18 In line with the company s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice.

More information

HEAT PUMP INSTALLATION MANUAL

HEAT PUMP INSTALLATION MANUAL DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL Models: TERRA09HP230V1A TERRA12HP230V1A TERRA18HP230V1B TERRA24HP230V1B Thank you for choosing a Gree Terra Ductless Heat Pump for your customer. Please

More information

Inverter Air Conditioner Installation Manual

Inverter Air Conditioner Installation Manual Inverter Air Conditioner Installation Manual KSV25CRG, KSV35CRG, KSV70CRG, KSV25HRG, KSD25HRG, KSV35HRG, KSD35HRG, KSV50HRG, KSD50HRG, KSV70HRG, KSD70HRG, KSV80HRG, KSD80HRG Congratulations Contents Congratulations

More information

Split Air Conditioner

Split Air Conditioner Split Air Conditioner Owner's Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners,please read this owner s manual carefully before operation and retain it for future

More information

Mini-Split Air Conditioner

Mini-Split Air Conditioner Cassette Type Installation Manual New Released A-Cassette-600 Mini-Split Air Conditioner DC Inverter Cassette Type Unit All Model Numbers Table of Contents Installation Manual 2 3 Accessories... 04 Safety

More information

GDDEM10 DEHUMIDIFIER

GDDEM10 DEHUMIDIFIER GDDEM10 DEHUMIDIFIER SOCIABLE REMARK When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste.

More information

Installation Manual Super-Slim Four-Way Cassette

Installation Manual Super-Slim Four-Way Cassette Installation Manual Super-Slim Four-Way Cassette Models: MCOVT S / MROVT AS IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

KTIM. Four-way Cassette Type

KTIM. Four-way Cassette Type KTIM INSTALLATION MANUAL Four-way Cassette Type Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.

More information

WH-TD20B3E5 WH-TD30B3E5

WH-TD20B3E5 WH-TD30B3E5 Order No: PHAAM1004143C2 WH-TD20B3E5 WH-TD30B3E5 WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type KSWT SERIES INSTALLATION INSTRUCTION Wall-mounted Split Type INSTALLATION 1. Characteristics of refrigerant 1.1 Temperature-pressure relationships in saturated condition Pressure (kg/cm2 G) 35 30 25 20

More information

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Split-type Air-Conditioner MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Deutsch Français Nederlands Español Italiano

More information

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 INSTALLATION, OPERATION & MAINTENANCE MANUAL InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100

More information

Dual-Hose Portable Air Conditioner User Manual

Dual-Hose Portable Air Conditioner User Manual Dual-Hose Portable Air Conditioner User Manual Model: IPA2-1244-C Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER CEILING & FLOOR TYPE AIR CONDITIONER Installation Manual Ceiling & Floor Type IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

Inverter Air Conditioner Installation Manual

Inverter Air Conditioner Installation Manual Inverter Air Conditioner Installation Manual KSV25CRH, KSV35CRH, KSV71CRH, KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH Congratulations Contents Congratulations

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information

SPLIT WALL-MOUNTED AIR CONDITIONER

SPLIT WALL-MOUNTED AIR CONDITIONER SPLIT WALL-MOUNTED AIR CONDITIONER MODELS: WS 090C / WS 090H / WS00H EMAILAIR I N S T A L L A T I O N I N S T R U C T I O N S ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2 LOCATION OF INDOOR AND OUTDOOR

More information

Wall Air Handler Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Wall Air Handler Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual Presents Wall Air Handler Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual 615000156 REV B, 11/12/2018 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com

More information

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B P/N: 52FS2B54070-R CONTENTS PRECAUTIONS Important Safety Information Hints For Economical Operation Standard Safety Instructions

More information

OWNER S MANUAL. Split Air Conditioner IVIH121A / OVIH121A IVIH241A / OVIH241A IVIH361A / OVIH361A

OWNER S MANUAL. Split Air Conditioner IVIH121A / OVIH121A IVIH241A / OVIH241A IVIH361A / OVIH361A OWNER S MANUAL Split Air Conditioner IVIH121A / OVIH121A IVIH241A / OVIH241A IVIH361A / OVIH361A Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If

More information

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1 GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E Figure 1 PET OWNERS WARNING: Health warning for some small pets, including birds, as they are extremely sensitive to the fumes produced

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL.   Please read this manual carefully before operating your set and retain it for future reference. ENGLISH OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. Ceiling Suspended Original instruction ARNU18GV1A4 ARNU24GV1A4 ARNU36GV2A4

More information

DAIKIN AIR CONDITIONER

DAIKIN AIR CONDITIONER 3P226011-1A M07B242A DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual

More information