Contents SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
|
|
- Victoria Leonard
- 5 years ago
- Views:
Transcription
1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-05LEA0 HSU-0LEA0 HSU-09LEA0 HSU-LEA0 HSU-8LEA0 HSU-LEA0 HSU-4LEA0 HSU-09LEA-W HSU-0LEA0-T HSU-LEA-W HSU-8LEA-W HSU-LEA-W HSU-LEA0-T HSU-09LEB-H HSU-4LEA-H HSU-8CRA0-T HSU-HEA0/(BP) HSU-09HEA0/(BP) HSU-09LEA-H HSU-8HEA0(T) HSU-8HEA(T) HSU-CRA0-T HSU-HEA0/(DB) HSU-09HEA0/(DB) HSU-09LEA-F HSU-LEA-H HSU-8LEA-H HSU-LEA-F HSU-LEA-M HSU-8LEA-M HSU-0HEA0 HSU-09HEA0 HSU-HEA0 HSU-8HEA0 HSU-HEA0 HSU-4HEA0 HSU-LEB-H HSU-4LEB-H HSU-09CRA0-T AMS09H0-N AMSH0-N AMS8H0-N AMSH0-N PAS8L0-N(T) HSU-0HEA-B HSU-09HEA-B HSU-HEA-B HSU-8HEA-B HSU-8LEA0(T) HSU-8LEA(T) HSU-09CA HSU-CA HSU-CB HSU-8LB HSU-8LA HSU-4LA HSU-HEB0 HEC-8LEA0(T) HSU-09LM HSU-LM HSU-0LEA-B HSU-09LEA-B Contents PARTS AND FUNCTIONS OPERATION MAINTENANCE CAUTIONS TROUBLE SHOOTING Please read this operation manual before using the air conditioner. Keep this operation manual for future reference
2 A U T O 8 4 Parts and Functions Indoor Unit Inlet 45 Horizontal flap (adjust up and down air flow Inlet grille Don't adjust it manually) Air Purifying Filter (inside) 6 Vertical blade (adjust left and right air flow) 54 Outlet Anion generator(inside) Actual inlet grille may vary from the one shown in the manual according to the product purchased Display board Signal receiver hole COOL display HEAT display Ambient temp.display When receiving the remote control signal, display the set and in the rest time the room is displayed and this room is only for reference. Outdoor Unit OUTLET INLET Clock set 4 5 HEALTH display (If the unit which you purchased has healthy function,follow it. If not,please ignore.) 6 Dry display OFF display ON display display CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE Press button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease min. If the button is kept pressed,time will change quickly. After time setting is confirmed,press, "AM "and "PM" stop flashing,while clock starts working Remote controller ON AM o C PM OFF HEALTH POWER/SOFT. Operation mode display. display. SPEED display AUTO 4. HEALTH display 5. display 6. display RE LO MED HI Operation mode AUTO COOLDRY HEAT Remote controller Display board 4. SIGNAL SENDING display 8. OFF display 9. ON display 0. display. display. POWER Used for unit start and stop.. Used to select AUTO run, COOL, HEAT DRY and operation 4. Used to select fan speed LO, MED, HI, AUTO (This function is unavailable on some models.) 5. HOUR Used to set clock and timer setting. 6. Used to set auto fan direction.. Used to select sleep mode. (This function is unavailable on some models.) 8. Used to lock buttons and LCD display. 9.. Used to select your desired temp. 0. Used to confirm timer and clock settings.. Used to select ON, OFF, ON-OFF. Used to set correct time. RE Used to reset the controller back to normal condition. 4. HEALTH Used to operate the healthy function 5. POWER/SOFT button This function is unavailable on some models. 6. POWER/SOFT display This function is unavailable on some models. NOTE: Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function,follow it.if not,please ignore. 4 Loading of the battery Remove the battery cover; Load the batteries as illustrated. R-0 batteries, resetting key(cylinder); Be sure that the loading is in line with the" + "/"-"; Load the battery,then put on the cover again. Note: The distance between the signal transmission head and the receiver hole should be within m without any obstacle as well. When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals, so the distance to the indoor unit should be shorter. Full display or unclear display during operation indicates the batteries have been used up.please change batteries. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key
3 O Operation Unit start / stop Press button, unit starts or stops. Auto Operation According to the automatic choice system in in indoors cold or make the hot movement Select temp.setting Operation Mode AUTO Display Board Remote Controller Note Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room. When is set to AUTO, the air conditioner automatically adjusts the fan speed according to room. Dry Operation COOL DRY In DRY mode, when room becomes lower than temp.setting+ o C,unit will run intermittently at LOW speed regardless of setting. HEAT nothing Cool Operation In operation mode, the unit will not operate in COOL or HEAT mode but only in mode,auto is not available in mode.and temp.setting is disabled. In mode, operation is not available. Note: In DRY mode, when room becomes lower than temp. o setting+ C, unit will run intermittently at LOW speed regardless of setting. Fan Operation (This function is unavailable on some models.) Heat Operation. When is set to AUTO, the air conditioner automatically adjusts the fan speed according AUTO LO MED HI to room..in operation mode the unit will not operate in COOL mode but only in mode,auto is not available in mode.and temp.setting is disabled. () Air Flow Direction Adjustm Note: In HEAT mode,warm air will blow out after a short periodof the time due to cold-draft prevention function. When is set to AUTO, the air conditioner automatically adjusts the fan speed according to room. Cooling only unit do not have displays and functions related with heating HEALTH Remote controller can memorize each operation status. When starting it next time,just press button and unit will run in previous status.
4 Operation HEALTH Operation (This function is unavailable on some models.) HEALTH POWER/SOFT RE The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. POWER/SOFT Operation () POWER Operation When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically HEALTH POWER/SOFT takes medial speed of AUTO fan mode. RE (This function is unavailable on some models.) To cancel POWER operation Press POWER/SOFT button twice,power/soft disappears. () SOFT Operation You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed automatically takes low speed of AUTO fan mode. HEALTH POWER/SOFT RE Healthy Negative ions To cancel SOFT operation Press POWER/SOFT button again,power/soft disappears. Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically a following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. () ON Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes,cooling or fan or heat,according to the room. Room Operation mode ABOVE O C COOLING BELOW O C HEAT Designated O C Timer mode 6 O C NO NO Air flow AUTOMATIC AUTOMATIC Pi () OFF (Cooling only uint) Room Operation mode Designated Timer mode Air flow BELOW O C 6 O C NO AUTOMATIC It is not possible to operate in dry mode. () ON-OFF (This function is unavailable on some models.) To cancel mode Just press button several times until mode disappears. Test operation: Test operation switch is the same as emergency switch. Use this switch in the test operation when the room is below 6 o C, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice,release your finger from the switch: the cooling operation starts with the air flow speed "Hi". Pi Pi After 0 minutes, test operation ends automatically(only for K,4K unit).
5 Operation Comfortable Before going to bed,you can simply press the button and unit will operate in mode and bring you a sound sleep. Operation HEALTH POWER/SOFT RE (This function is unavailable on some models.). In HEAT mode hours after mode starts, temp will become O C lower than temp.setting. After another hours, temp decrease by O C further. After more another hours, temp. O rises by C further. The unit will run for further hours then stops. Temp. is lower than temp. setting so that room won't be too high for your sleep. Temp.setting Unit stop hr Decreases O C hr Decreases O C hrs hrs Rises O C operation starts operation stops In HEAT mode Operation Mode. In COOL,DRY mode hours after mode starts, temp. will become O C higher than temp. setting. After another hours, temp. rises by O C further. The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room won't be too Iow for your sleep. operation stops operation starts Approx.6hrs hr hr Rises O C Rises O C Temp.setting Unit stop In COOL, DRY mode.in AUTO mode The unit operates in corresponding sleep mode corresponding sleep mode adapted to the automatically selected operation mode. 4. In mode It has no function. 5. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted.when function is set,the quiet sleeping function can't be set up.after the sleeping function is set up,if user resets function, the sleeping function will be cancelled; the machine will be in the state of timing-on,if the two modes are set up at the same time,either of their operation time is ended first,the unit will stop automatically,and the other mode will be cancelled. Power Failure Resume Function If the unit is started for the first time, the compressor will not start running unless minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and minutes later the compressor starts running. Note to the power failure resume: press the sleep button ten times in five seconds and enter function after hearing four sounds.and press the sleep button ten times within five seconds and leave this function after hearing two sounds. 4
6 Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet or outlet Remote Controller Indoor Body Proper Do not use water,wipe the controller with a dry cloth.do not use glass cleaner or chemical cloth. Wipe the air conditioner by using a soft and dry cloth.for serious stains,use a neutral detergent diluted with water.wring the water out of the cloth before wiping.then wipe off the detergent completely. Close doors and windows during operation Use the timer effectively Do not use the following for cleaning During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used for a long time, turn off the power supply main switch. OFF Use the louvers effectively Replacement of Air Purifying Filter.Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit..detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it..attach Air Purifying Filter Detach old Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. Gasoline,benzine, thinner or cleanser may damage the coating of the unit. Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water.after washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front.make sure that the filter is completely fixed behind the stopper.if the right and left filters are not attached correctly, that may cause defects. Close the inlet grille. (NOTE: Air purifying filter is optional part) 4.Attach the standard air filter (Necessary installation) 5.Close the Inlet Grille Close the Grille surely Hot water over 40 O C(04 O F) may cause discoloring or deformation. Once every two weeks ATTENTION: The white side of the photocatalyst air purifying filter face outside,and the black side face the unit. The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit. NOTE: The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them,you should remove the dust frequently by using vacuum cleaner or flaping them lightly,otherwise, its performance will be affected. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it,or its ability of sterilization will be reduced. 5
7 Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. WARNING Use an exclusive power source with a circuit breaker Check proper installation of the drainage securely OFF Connect power supply cord to the outlet completely Do not use power supply cord in a bundle. Use the proper voltage Take care not to damage the power supply cord..do not use power supply cord extended or connected in halfway.do not install in the place where there is any possibility of inflammable gas leakage around the unit..do not get the unit exposed to vapor or oil steam. Do not insert objects into the air inlet or outlet. Do not start or stop the operation by disconnecting the power supply cord and so on. Do not channel the air flow directly at people, especially at infants or the aged. Do not try to repair or reconstruct by yourself. Connect the earth cable. earthing Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation. CAUTION Take fresh air occasionally especially when gas appliance is running at the same time. Do not operate the switch with wet hand. Do not install the unit near a fireplace or other heating apparatus. Check good condition of the installation stand Do not pour water onto the unit for cleaning Do not place animals or plants in the direct path of the air flow Do not place any objects on or climb on the unit. Do not place flower vase or water containers on the top of the unit. 6
8 Trouble shooting Before asking for service, check the following first. Cautions Normal Performance inspection Multiple check Phenomenon The system does not restart immediately. Noise is heard Smells are generated. Mist or steam are blown out. In dry mode, fan speed can t be changed. Poor cooling Cause or check points When unit is stopped, it won't restart immediately until minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard.at first - minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard.this noise is generated by the casing expanding or shrinking because of changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes. During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air. In DRY mode, when room becomeslower than temp.setting+ o C,unit will run intermittently at LOW speed regardless of setting. Is power plug inserted? Is there a power failure? Is fuse blownout? Is the air filter dirty? Normally it should be cleaned every 5 days. Are there any obstacles before inlet and outlet? Is set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(use curtain) Are there too much heat sources or too many people in the room during cooling operation? The machine is adaptive in following situation.applicable ambient range: For: T For: T Cooling Heating Cooling Outdoor Indoor Heating Outdoor Indoor Minimum: D.B / W.B Outdoor Maximum: D.B Minimum: D.B Indoor Maximum: D.B Minimum: D.B Outdoor Minimum: D.B / W.B Indoor Minimum: D.B / W.B Minimum: D.B Maximum: D.B Minimum: D.B Minimum: D.B / W.B o C/ o C 8 o C/4 o C 4 o C/6 o C 8 o C o C 5 o C 4 o C/8 o C - o C/-8 o C 9 o C/9 o C 8 o C/4 o C 54 o C/4 o C 8 o C o C 5 o C 4 o C/8 o C - o C/-8 o C. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H0RN-F. If the fuse on PC board is broken please change it with a fuse type T..5A/50V. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 5A/50V. 4.The distance between the indoor unit and the floor should be more than m. 5.The wiring method should be in line with the local wiring standard. 6. After installation, the power plug should be easily reached...the used batteries should be disposed of properly. 8.The appliance is not intended to use by young children or infirm persons without supervision. 9.Young children should be supervised ensure that they do not play with the appliance. 0.The appliance must be installed on a strong enough support..the wiring diagram is attached inside the machine. T: T: Application temp. range of air conditioner - o C~4 o C. Application temp. range of air conditioner - o C~54 o C.
HSU-09LEK03-Y4 HSU-12LEK03-Y4 HSU-18LEK03-Y4 HSU-24LEK03-Y4 HSU-12CK6B2 HSU-18LK2W3 HSU-18LK6B2 HSU-24LK2S2 HSU-24LEK03 HSU-18LEK03EK1 HSU-26HEK03
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-0LEK0 HSU-09LEK0 HSU-LEK0 HSU-09LEK HSU-LEK HSU-0HEK0 HSU-09HEK0 HSU-HEK0 HSU-8LEK HSU-4LEK HSU-LEK-M HSU-8HEK0 HSU-4HEK0 HSU-09LEK0-Y HSU-LEK0-Y HSU-8LEK0-Y
More informationSPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL. Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AS09TBHRA ASTBHRA AS8TDHRA ASTEHRA AS6TBHRA AS5TBHRA AS5TDHRA AS7TEHRA Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS
More informationContents SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL PARTS AND FUNCTIONS OPERATION MAINTENANCE CAUTIONS TROUBLE SHOOTING
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-8LEG0(T) HSU-8HEG0(T) HSU-LEG0(T) HSU-HEG0(T) HSU-8LEG(T) HSU-8HEG(T) HSU-LEG(T) HSU-HEG(T) HSU-0HEG(T) HSU-0LEG(T) HST-HEG(T) HST-LEG(T) HST-0LEG(T)
More informationWall Mounted Mini Split Heat Pump Air Conditioner
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHHP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus
More informationOPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N
OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9378015029 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 OPERATION... 2
More informationFLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N
OPERATING MANUAL AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE ABT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9375756024 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS...
More informationCONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!
CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...
More informationOPERATING MANUAL COOLING MODEL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST9ASJCW AST12ASJCW
OPERATING MANUAL COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit AST9ASJCW AST1ASJCW Outdoor Unit AOT9AEJC AOT1ASJC KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED
More informationInverter Split-type Room Air Conditioner
OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
More information53 KNL / 53 QNL OWNER S MANUAL
53 KNL / 53 QNL /OFF OWNER S MANUAL Split system air conditioner Contents Page Precautions... Unit description... 4 Remote controller description... 6 Remote controller preparation... 8 Unit operation...
More informationOPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N
OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...
More informationOPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE
OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379583 CONTENTS SAFETY PRECAUTIONS... 2 FEATURES AND FUNCTIONS...
More informationSPLIT TYPE. Instruction manual
SPLIT TYPE Instruction manual ENGLISH Instruction manual Page 1~24 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. 1 SAFETY PRECAUTION
More informationCASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM
OPERATING MANUAL AIR CONDITIONER CASTE TYPE AUT Series AM PM 6 9 5 8 KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9704 CONTENTS SAFETY PRECAUTIONS... NAME OF PARTS... PREPARATORY OPERATION...
More informationAH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH INDOOR UNIT OUTDOOR UNIT AH-PNX AU-PNX AH-PNX4 AU-PNX4 Device of this mark is a trademark of Sharp Corporation. Plasmacluster is a registered trademark
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-260GA/RAC-260GA RAS-350GA/RAC-350GA OUTDOOR UNIT INDOOR UNIT RAC-260GA RAS-260GA RAS-350GA RAC-350GA Instruction manual Page 1~24 To obtain
More informationKSD-35 DR11 KUE-35 DVN11
FLOOR-STANDING TYPE AIR CONDITIONER Owner s Manual Floor-Standing Type KSD-35 DR11 KUE-35 DVN11 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.
More informationWINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES ROOM AIR CONDITIONER WINDOW TYPE COOLING MODEL
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-50YHA/RAC-50YHA OUTDOOR UNIT INDOOR UNIT RAC-50YHA RAS-50YHA Instruction manual Page 1~26 To obtain the best performance and ensure
More informationCONTENTS SAFETY PRECAUTIONS. En-2 DANGER! WARNING! CAUTION! DANGER! CAUTION!
CONTENTS SAFETY PRECAUTIONS... FEATURES AND FUNCTIONS... 3 NAME OF PARTS... 4 PREPARATION... 6 OPERATION... 7 TIMER OPERATION... 9 SLEEP TIMER OPERATION... 0 ADJUSTING THE DIRECTION OF AIR CIRCULATION...
More informationSPLIT - TYPE ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT - TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how
More informationAY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT
R AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL INDOOR UNIT AY-AP09DJ OUTDOOR UNIT AE-A09DJ ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before
More informationCompact Cassette Type
Compact Cassette Type PART NO.9374379392-04 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 2 NAME OF PARTS... 3 PREPARATORY OPERATION... 4 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER...
More informationUSER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series
USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series ENGLISH FRANÇAIS ESPAÑOL Split - type Air Conditioner (Cooling and Heating) E S F DB98-27559A(1) Contents PREPARATION Safety
More informationOperating Instructions Air Conditioner
F566276 Operating Instructions Air Conditioner CS-C45FFH CU-C45FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. CONTENTS Safety Precautions...
More informationOWNER S MANUAL VMH 09/12/18/24
OWNER S MANUAL VMH 09/12/18/24 Version C Inverter Single Zone Ductless Mini-Split Heat Pump Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com VMH Inverter
More informationOwner s Manual Super-Slim Four-Way Cassette
CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-80YHA/RAC-80YHA INDOOR UNIT OUTDOOR UNIT RAS-80YHA RAC-80YHA Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use,
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-72CHA3/RAC-72CHA3 INDOOR UNIT OUTDOOR UNIT RAS-72CHA3 RAC-72CHA3 Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free
More informationROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.
Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how to
More informationGMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS
GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS SAFETY PRECAUTIONS 3 PARTS NAMES 5 OPERATING TEMPERATURE 6 MANUAL OPERATION 7 ADJUSTING AIRFLOW DIRECTION 8 HOW THE AIR CONDITIONER WORKS
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER ENGLISH ENGLI INDOOR UNIT/OUTDOOR UNIT MODEL RAS-DX10CSK/RAC-DX10CSK RAS-DX13CSK/RAC-DX13CSK RAS-DX18CSK/RAC-DX18CSK OUTDOOR UNIT INDOOR UNIT RAS-DX10CSK RAS-DX13CSK RAS-DX18CSK
More informationDAIKIN ROOM AIR CONDITIONER. Operation Manual ATXD60CV4 ATXD71CV4 ATXD80CV4
00_CV_3P145995-1C.fm Page 1 Tuesday, July 26, 2005 9:04 AM DAIKIN ROOM AIR CONDITIONER MODELS ATXD50CV4 Operation Manual ATXD60CV4 ATXD71CV4 ATXD80CV4 CONTENTS READ BEFORE OPERATION Safety precautions...
More informationNEXXOS INVERTER USER MANUAL
NEXXOS INVERTER USER MANUAL NIN412C2V32 NIN415C2V32 NIN520C2V32 NIN725C2V32 INVERTER MINI SPLIT SYSTEM WARNING The information contained in the manual is intended for use by a qualified service technician
More informationR410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.
AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. THIS PRODUCT
More informationHEAT & COOL MODEL (REVERSE CYCLE)
OPERATING MANUAL HEAT & COOL MODEL (REVERSE CYCLE) AIR CONDITIONER Duct Type Indoor Unit ARTG09LL ARTG12LL ARTG18LL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379439 CONTENTS SAFETY PRECAUTIONS... 1
More informationHEAT & COOL MODEL (REVERSE CYCLE)
OPERATING MANUAL HEAT & COOL MODEL (REVERSE CYCLE) ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit AST9LSACW AST12LSACW Outdoor Unit AOT9LSAC AOT12LSAC KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
More informationR410A SPLIT SERIES FIXED SPEED
R410A SPLIT SERIES FIXED SPEED Models ECO901SN ECO1201SN ECO1801SN ECO2401SN Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-70YHA / RAC-70YHA OUTDOOR UNIT INDOOR UNIT RAC-70YHA RAS-70YHA Instruction manual Page 1~23 To obtain the best performance and ensure years of trouble
More informationCONTENTS READ BEFORE OPERATION
CONTENTS READ BEFORE OPERATION Safety Precautions... Names of Parts Indoor unit, Opening the front grille... 5 Remote controller... 6 Outdoor unit... 7 Preparation Before Operation Remote controller...
More informationUtopian Split A/C. Thank you for purchasing this quality Split A/C system!
Utopian Split A/C Thank you for purchasing this quality Split A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any operation
More informationOperating Instructions Air Conditioner
F56579 Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS-E18GKR CS-E1GKR CS-E4GKR CS-E8GKR CU-E18GKR CU-E1GKR CU-E4GKR CU-E8GKR Before operating the unit, read these operating instructions
More informationUsing the Remote Control Unit
Remote Control Unit (continued) SENSOR button Temperature Display Selector button Time Display Selector button ACL button (ALL CLEAR) When you press this button (use a small-tipped object such as a ballpoint
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-51CHA3/RAC-51CHA3 RAS-63CHA3/RAC-63CHA3 OUTDOOR UNIT INDOOR UNIT RAS-51CHA3 RAS-63CHA3 RAC-51CHA3 RAC-63CHA3 Instruction manual Page
More informationOPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N
OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379224 07H050_cover.p65 2007.8.7, 0:27 AM CONTENTS SAFETY PRECAUTIONS... FEATURES
More informationCASSETTE TYPE
CASSETTE TYPE 9378589032-04 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 2 NAME OF PARTS... 2 PREPARATION... 4 OPERATION... 5 TIMER OPERATION... 7 SLEEP TIMER OPERATION... 8 FILTER INDICATOR
More informationRoom Air Conditioners
User Manual Room Air Conditioners R410A Split Type Nouveau Series DC INVERTER ECO930SDN ECO1230SDN Please read this installation manual completely before installing the product. When the power cord is
More informationINVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER
INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual Model: 3554190/3554191/3554192/3554193 3554194/3554195/3554196/3554197 IMPORTANT NOTE: Read this manual carefully
More information9 = Fig. 1. Fig. 2. Fig. 3. Fig. 5 % Fig. 4 $ Fig. 6 ) Fig. 8. Fig. 7 MED FAN DRY LOW QUIET CLOCK TIMER RESET AM SLEEP OFF ON AUTO AUTO
1 Fig. 1! Fig. 2 3 4 5 9 = OPERATION TIMER SWING 6 0 7 - ~ Fig. 3 8 Fig. 5 % # @ $ Fig. 4 ^ Fig. 6 ) & SLEEP TIMER _ CLOCK PM * ( MASTER SET SET FAN CONTROL TEMP. TIME CONTROL START/STOP SWING AIR FLOW
More informationCONTENTS SAFETY PRECAUTIONS DANGER! CAUTION!
937437936_OM_cover.p65 //08, 3:48 CONTENTS SAFETY PRECAUTIONS... FEATURES AND FUNCTIONS... NAME OF PARTS... PREPARATION... 4 OPERATION... 5 TIMER OPERATION... 7 SLEEP TIMER OPERATION... 8 FILTER LAMP RESET...
More informationSPLIT TYPE
ROOM AIR CONDITIONER SPLIT TYPE OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES Português EλληvIkά Italiano
More informationSplit Air Conditioner
O W N E R ' S M A N U A L M A N U A L C&H A IR C O N D ITI O N E R S Split Air Conditioner SMART SERIES MODELS: CH-S07LH/R CH-S09LH/R CH-S12LH/R СH-S18LH/R CH-S24LH/R Thank you for selecting С&H air conditioners.
More informationR410A ROOM AIR CONDITIONER WALL MOUNTED TYPE OPERATING MANUAL P/N REFRIGERANT KEEP THIS MANUAL FOR FUTURE REFERENCE.
ROOM AIR CONDITIONER WALL MOUNTED TYPE OPERATING MANUAL English R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil. THIS PRODUCT MUST ONLY BE INSTALLED
More informationOPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST24PBA AST30PBA. Outdoor Unit AOT24PMAL AOT30PMAL
OPERATING MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit AST4PBA AST0PBA Outdoor Unit AOT4PMAL AOT0PMAL KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N970400 CONTENTS
More informationDAIKIN ROOM AIR CONDITIONER. Operation Manual
DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE
More informationFUJITSU GENERAL LIMITED AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P/N
OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE Español Français English KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9359944058
More informationOperating Instructions Air Conditioner
F566113 Operating Instructions Air Conditioner Indoor Unit CS-E18HKR CS-E1HKR CS-E4HKR CS-E8HKR Outdoor Unit CU-E18HKR CU-E1HKR CU-E4HKR CU-E8HKR Before operating the unit, read these operating instructions
More informationCDKD25CVM CDKD35CVM Operation Manual
00_CV_3P196326-2.fm Page 1 Thursday, December 7, 2006 1:38 PM DAIKIN ROOM AIR CONDITIONER MODELS CDKD25CVM CDKD35CVM Operation Manual CDKD50CVM CDKD60CVM English Portugues CONTENTS READ BEFORE OPERATION
More informationOWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK
OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-0,, 8, 24, 0BKS-HK Outdoor unit RAS-0,, 8, 24, 0BAS-HK 065560 065560_EN.indd 9/0/2558 BE 5:07 PRECAUTIONS FOR
More informationOPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST18AB AST18RB AST24AB AST24RB AST30AB AST30RB
OPERATING MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit AST8AB AST8RB AST4AB AST4RB AST0AB AST0RB Outdoor Unit AOT8A AOT8R AOT4A AOT4R AOT0A AOT0R KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
More informationCONTENTS READ BEFORE OPERATION OPERATION CARE TROUBLE SHOOTING
CONTENTS READ BEFORE OPERATION Safety Precautions... Names of Parts Indoor unit, Opening the front grille... 4 Outdoor unit, Remote controller... 5 Preparation Before Operation Remote controller... 6 Indoor
More informationOwner s Manual SPLIT-TYPE ROOM AIR CONDITIONER
Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
More informationOwner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER
INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure
More informationDAIKIN ROOM AIR CONDITIONER. Operation Manual MODELS FTXS25EVMA FTKS25EVMA FTXS35EVMA FTKS35EVMA
00_CV_3P194539-3.fm Page 1 Sunday, November 19, 2006 2:06 PM DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTXS25EVMA FTKS25EVMA FTXS35EVMA FTKS35EVMA CONTENTS READ BEFORE OPERATION Safety precautions...
More informationAIR CONDITIONER (SPLIT TYPE)
OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-0, 22, 24NKCV(HK) Outdoor unit RAS-0, 22, 24NACV- 065557 PRECAUTIONS FOR SAFETY DANGER Do not install, repair,
More informationOperation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B DAIKIN ROOM AIR CONDITIONER.
DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B English Deutsch Français Nederlands Español Italiano ΕλληνικÜ
More informationR410A SPLIT SERIES DC INVERTER QUICK COUPLING
R40A SPLIT SERIES DC INVERTER QUICK COUPLING Models ECO906SQ ECO206SQ ECO806SQ Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a
More informationOwner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER
MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing
More informationOwner s Manual CS
Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. CS78421-548-754 Table of Contents
More informationOwner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER
INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure
More informationOwner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS
SPLIT-TYPE ROOM AIR CONDITIONER Owner s Manual Fairwind Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save
More informationSU MO TU WE TH FR SA AM PM
OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO AIR CONDITIONER CONCEALED CEILING TYPE Français English AM PM Español KEEP THIS MANUAL FOR FUTURE REFERENCE CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR
More informationWINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL
MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or
More informationINVERTER SPLIT-TYPE ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT-TYPE ROOM AIR CONDITIONER INVERTER The design and specifications are subject to change
More informationOPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST20AG. Outdoor Unit AOT20AN P/N
OPERATING MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit AST0AG Outdoor Unit AOT0AN KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9366760 CONTENTS SAFETY PRECAUTIONS...
More informationDAIKIN ROOM AIR CONDITIONER FTXS50FVMA FTKS50FVMA FTXS60FVMA FTKS60FVMA FTXS71FVMA FTKS71FVMA FTXS80FVMA FTXS90FVMA MODELS.
00_CV_3P194539-1.fm Page 1 Saturday, October 28, 2006 5:05 PM DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTXS50FVMA FTKS50FVMA FTXS60FVMA FTKS60FVMA FTXS71FVMA FTKS71FVMA FTXS80FVMA FTXS90FVMA
More informationMS7 Single Zone Mini Split System Air Conditioners and Heat Pumps
2011 Lennox Industries Inc. Dallas, Texas, USA 506789 01 08/2011 MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps This manual is the property of the homeowner and must be left with the
More informationOWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH
OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 4TVU00, 0, 08-70 Outdoor unit 8TVU00, 0, 08-70 0508 PRECAUTIONS FOR SAFETY DANGER Do not install, repair, open or
More informationCASSETTE AIR CONDITIONER OPERATION MANUAL
CASSETTE AIR CONDITIONER OPERATION MANUAL AB42NACMCA AU42NAIMBA (HBU-42CD03) AB28NACMAA AU28NAHMAA (HBU-28CD03) AB42NACACA AU42NAIACA (HBU-42HD03) AB282ACBBA AU282AHBDA (HBU-28HC03/R1) AB242ACAAA AU242AHABA
More informationTable of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...
User Manual Table of Contents Owner s Manual 0 1 Safety Precautions...04 Unit Specifications and Features...06 SAFETY FIRST 2 Manual Operation (Without Remote)...11 3 Care and Maintenance...12 4 Troubleshooting...14
More informationIndoor Unit (2 Series)
System Indoor Unit (2 Series) OWNER'S MANUAL Type: Wall mounted LG ENGLISH FRANÇAIS ESPAÑOL IMPORTANT Please read this owner's manual carefully and thoroughly before installing and operating your room
More informationFeatures. Simple One-touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation.
01_KMS1872_En.fm Page 2 Monday, November 14, 2005 1:28 PM Features This air conditioner is an inverter type unit that automatically adjusts capacity as appropriate. Details on these functions are provided
More informationOWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump
R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions
More informationROOM AIR CONDITIONER WALL MOUNTED TYPE
OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit MW18C3E MW18Y3E MW24C3E MW24Y3E MW30C3E Outdoor Unit MR18C3E MR18Y3E MR24C3E MR24Y3E MR30C3E English
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RPI-30MH1 / RAC-30MH1 OUTDOOR UNIT INDOOR UNIT RPI-30MH1 RAC-30MH1 Instruction manual Page 1~20 To obtain the best performance, please
More informationOWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)
OWNER S MANUAL HIGH WALL INVERTER (English) (MSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner
More informationCPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD
CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD eair LLC 12201 N.W. 107 Avenue, Medley, FL 33178 www.comfortstarusa.com Table of Contents Owner s Manual 0 1 Safety Precautions...04 Unit Specifications
More informationDAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.
DAIKIN ROOM AIR CONDITIONER Operation Manual FDXS25F2VEB FDXS60F2VEB FDXS35F2VEB FDXS50F2VEB English Deutsch Français Nederlands Español Italiano Ελληνικά Portugues Русский Türkçe CONTENTS READ BEFORE
More informationPORTABLE AIR CONDITIONER
OWNER S MANUAL PORTABLE AIR CONDITIONER Model: CH-M09K6S F or proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com
More informationSYSTEM Inverter Air Conditioners
OPERATION MANUAL SYSTEM Inverter Air Conditioners MODELS Ceiling-mounted Cassette type (Multi flow model) FXFQ12MVJU FXFQ18MVJU FXFQ24MVJU FXFQ30MVJU FXFQ36MVJU Read these instructions carefully before
More informationINDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-S10CC / RAC-S10CC RAS-5115CC / RAC-5115CC OUTDOOR UNIT INDOOR UNIT RAC-S10CC RAC-5115CC RAS-S10CC RAS-5115CC Instruction manual Page
More informationOPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST24LBAJ AST30LBAJ. Outdoor Unit AOT24LMADL AOT30LMADL
OPERATING MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit AST4LBAJ AST30LBAJ Outdoor Unit AOT4LMADL AOT30LMADL KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N93740805 CONTENTS
More informationBosch Split-Type Ductless Air Conditioner / Heat Pump
Bosch Split-Type Ductless Air Conditioner / Heat Pump Climate 5000 AA Series User Manual 2 Bosch Split Type Ductless Air Conditioner / Heat Pump User Manual Data subject to change 01.2017 Bosch Thermotechnology
More informationOWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11
OWNER S MANUAL A6 Duct KPD-35 DVN11 KPD-52 DVN11 KPD-71 DVN11 KPD-90 DVN11 KPD-105 DVN11 KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11 KPD-71 DVR11 KPD-105 DVR11 KPD-105 DTR11 KPD-140
More informationOWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)
OWNER S MANUAL HIGH WALL INVERTER (English) (BSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner
More informationDAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS35LV1A
DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS35LV1A CONTENTS READ BEFORE OPERATION Safety Precautions... 2 Names of Parts... 4 Preparation before Operation...
More informationBefore using this product, read these instructions thoroughly and keep this manual for future reference.
AIR CONDITIONER Wall Mounted Type Contents Safety Precautions...En- Indoor Unit Overview and Operations...En- Remote Controller Overview and Operations...En-3 Timer Operation...En-5 General Informations
More informationINVERTER SPLIT-TYPE ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT-TYPE ROOM AIR CONDITIONER The design and specifications are subject to change without
More informationHigh Wall Split Air Conditioners 53QHCT KHCT
Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. R22 220-240V ~ 50Hz 1Ph High Wall Split Air Conditioners 53QHCT 12-18-24 53KHCT 12-18-24 Heat Pump Cool Only OWNER S MANUAL Carrier is committed to
More informationINDOOR UNIT/OUTDOOR UNIT
ENGLISH SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-25YHA5/RAC-25YHA5 RAS-35YHA6 /RAC-35YHA6 INDOOR UNIT OUTDOOR UNIT RAS-25YHA5 RAS-35YHA6 RAC-25YHA5 RAC-35YHA6 Instruction manual Page
More information