AIR TO WATER AIR TO WATER

Size: px
Start display at page:

Download "AIR TO WATER AIR TO WATER"

Transcription

1 IR TO TER IR TO TER Versati Versati (Split ) Versati (Monobloc ) Split ater Heater Integral ater Heater Direct & Circulating ater Heater PX Series Multifunctional irtowater Heat Pump 7/7

2 IR TO TER VERSTI Versati II water heater can perform cooling, heating, water heating, cooling+water heating, and heating+water heating. It can be connected to radiator, floor or fan coil for heat radiation. Outdoor Unit Power Supply * Power Input* /COP* * Power Input* /COP* Sanitary water Temperature Sound Pressure cooling evel heating Gas Connecting pipe iquid s ( D H) Packaged 4 GP oading quantity 4 HQ inch() inch() GRSCQ8.Pd/NaEK(O) ~4// / / ~ φ5.9 φ9.5 98x47x788 97x478x967 8/ GRSCQPd/NaEK(O) ~4// / / ~ φ5.9 φ9.5 98x47x788 97x478x967 8/ GRSCQPd/NaEK(O) ~4// / / ~ φ5.9 φ9.5 9x4x x458x55 7/7 5 5 GRSCQ4Pd/NaEK(O) ~4// / / ~ φ5.9 φ /7 5 5 uxiliary electric heater High efficiency Item ater Golden fin condenser Easier maintainability. ater Side eaving ater Temperature( 7~5 5~55 4~8(ater Tank Temperature) Quiet function Compact design Note: hen operating conditions are out of the range listed above, please contact Gree. Intelligent defrosting ow voltage startup Heat Source/User Side Environment Dry Bulb Temperature( ~48 ~ ~45 Energy saving function This unit is very powerful, smart and userfriendly, featuring various functions including holiday mode, absence mode, quiet mode, quiet pre, clock timer, weekly timer, holiday exclusion, floor ting, environment dependency mode, etc.. Power Supply * Power Input* /COP* * Power Input* /COP* Sanitary water Temperature Sound Pressure cooling evel heating Gas Connecting pipe iquid s ( D H) Packaged 4 GP oading quantity 4 HQ inch() inch() GRSCQ6Pd/NaEK(O) ~4// / / ~ φ5.9 φ /7 5 5 GRSCQPd/NaEM(O) 38~45V/3/ / / ~ φ5.9 φ /4 5 5 GRSCQ4Pd/NaEM(O) 38~45V/3/ / / ~ φ5.9 φ /4 5 5 Notes:.This product model is under development..gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. *.Capacites and power inputs are based on the following conditions: conditions. Indoor ater Temperature 3/8. Outdoor ir Temperature DB/4B. conditions. Indoor ater Temperature 3/. Outdoor ir Temperature 7DB/6B. Standing piping length 5m. GRSCQ6Pd/NaEM(O) 38~45V/3/ / / ~ φ5.9 φ /4 5 5 *.Capacites and power inputs are based on the following conditions: conditions. Indoor ater Temperature /7. Outdoor ir Temperature DB/4B. conditions. Indoor ater Temperature 4/45. Outdoor ir Temperature 7DB/6B. Standing piping length 5m. performance satisfies EU ERP energy efficiency, with a rating up to ++. Motor and water pump elements conform to the requirements out by the EU Eco Directive. It can perform cooling, heating, water heating, cooling+water heating, and heating+water heating, and can be connected to radiator, floor or fan coil for heat radiation. 73/74

3 IR TO TER Indoor Hydro Unit Indoor unit Power Supply Nominal input eaving water temperature 3 4 Pump Nr. of speed PM Operation Steps Electric Heater Combination Sound pressure level Connecting pipe Gas inch() iquid inch() s ( D H) Packaged oading quantity 4 GP 4 HQ GRSCQ8.Pd/NaEK(I) ~4// Ph/~4V/5Hz 3 φ5.9 φ / GRSCQPd/NaEK(I) ~4// atercooled Variablespeed 475 utomatic Ph/~4V/5Hz 3 φ5.9 φ / GRSCQPd/NaEK(I) ~4// Ph/~4V/5Hz 3 φ5.9 φ / ater Tank SXVDCJ/K SXVDCJ/K SXVD3CJ/K SXVD3CJ/K ater tank volume 3 3 /3/5 /3/5 /3/5 /3/5 Electric heater power Cool water inlet inch() Screw thread spec of pipe Hot water outlet Diameter H inch() φ φ φ6 6 φ6 6 Packaged D H 63x68x645 63x68x x78x75 648x78x75 68/77 7/8 8/9 87/97 oading quantity 4'GP/4'HQ 75/ 75/ 63/63 63/63 ater tank volume Electric heater power Screw thread spec Cool water inlet of pipe Hot water outlet Diameter H Packaged D H oading quantity 4'GP/4'HQ inch() inch() φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) SXVDCJ/M SXVDCJ/M SXVD3CJ/M SXVD3CJ/M 3 3 3/4/5 3/4/5 3/4/5 3/4/ φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ φ φ6 6 φ6 6 63x68x645 63x68x x78x75 648x78x75 68/77 7/8 8/9 87/97 75/ 75/ 63/63 63/63 Indoor unit GRSCQ4Pd/NaEK(I) GRSCQ6Pd/NaEK(I) GRSCQPd/NaEM(I) GRSCQ4Pd/NaEM(I) GRSCQ6Pd/NaEM(I) Power Supply ~4//5 ~4//5 38~45/3/5 38~45/3/5 38~45/3/5 Nominal input eaving water temperature RS5/7.5 RS5/7.5 RS5/7.5 RS5/7.5 RS5/7.5 Pump Nr. of speed 8 / / / / / PM Operation Yes Yes Yes Yes Yes Steps Electric Heater Combination Ph/~4V/5Hz Ph/~4V/5Hz 38~45V/3Ph/5Hz 38~45V/3Ph/5Hz 38~45V/3Ph/5Hz Sound pressure level Gas inch() φ5.9 φ5.9 φ5.9 φ5.9 φ5.9 Connecting pipe iquid inch() φ9.5 φ9.5 φ9.5 φ9.5 φ9.5 s ( D H) Packaged /66 57/66 58/67 58/67 58/67 4 GP oading quantity 4 HQ Note: * for floor cooling * for fan coil cooling*3 for floor heating*4 for fan coil heating. 75/76

4 IR TO TER VERSTI + (Split ) It is a kind of DC inverter multifunctional air to water heat pumps that could not only supply domestic hot water, but also realize cooling or heating for residential use. Item ater ater Side eaving ater Temperature( 7~5 5~6 4~8(ater Tank Temperature) Heat Source/User Side Environment Dry Bulb Temperature( ~48 ~ ~45 Note: hen operating conditions are out of the range listed above, please contact Gree. Outdoor Unit GRSCQ8.Pd/NaDK(O) GRSCQPd/NaDK(O) GRSCQPd/NaDM(O) GRSCQ4Pd/NaDM(O) Floor Debugging High efficiency Quiet function Selfdiagnosis ide voltage range Comprehensive protection Compact design Power Supply 4//5 4//5 3845/3/5 3845/3/ * Power Input* /COP* 4.4/ /4. 3.9/ / * Power Input* /COP*.97/3.4.95/ /3.7 3./ Sanitary water Temperature 4~8 4~8 4~8 4~8 Sound Pressure cooling evel heating Connecting pipe Gas inch() iquid inch() s ( D H) Packaged /87 85/87 6/36 6/36 oading quantity 4 GP HQ Notes:.Capacites and power inputs are based on the following conditions: conditions. Indoor ater Temperature 3/8. Outdoor ir Temperature DB/4B. conditions. Indoor ater Temperature 3/. Outdoor ir Temperature 7DB/6B. Standing piping length 7.5m..Capacites and power inputs are based on the following conditions: conditions. Indoor ater Temperature /7. Outdoor ir Temperature DB/4B. conditions. Indoor ater Temperature 4/45. Outdoor ir Temperature 7DB/6B. Standing piping length 7.5m. Twin rotary DC inverter compressor creates comfortable living circumstance and saves energy. The electronic expansion valve guarantees that the system made adjustments automatically according to the changes of the circumstance and water temperature. Smart dualtemperature detection control technology. The disinfection function at a high temperature up to 7 can prevent the growth of bacteria and ensure sanitary water, creating a wholesome life for users. Isolation of water and electricity ensures safe operation. Dualcoil design makes it convenient to join solar panel or boiler. Fivemode operation: heating, cooling, water heating, heating and water heating, cooling and water heating. The unit will periodically increase or decrease water temperature in debugging process, to improve floor adaptability for temperature change. 77/78

5 IR TO TER Indoor Hydro Unit Indoor unit Power Supply Norminal input * eaving water * temperature * * Nr. of speed Pump ater flow limit Operation Steps Electric Heater Combination Sound pressure level Gas Connecting pipe iquid s ( D H) Packaged 4'GP oading quantity 4'HQ PM inch() inch() GRSCQ8.Pd/NaDK(I) GRSCQPd/NaDK(I) GRSCQPd/NaDM(I) ~4// watercooled variablespeed // x5x34 43x68x395 56/ ~4// watercooled variablespeed // x5x34 43x68x395 56/ ~45/3/ watercooled variablespeed /3/ x5x34 43x68x395 58/ GRSCQ4Pd/NaDM(I) 38~45/3/ watercooled variablespeed /3/ x5x34 43x68x395 58/ VERSTI + (Monobloc ) It is a kind of DC inverter multifunctional air to water heat pump that could not only supply domestic hot water, but also realize cooling or heating for residential use. /3 ater Tank SXVDCJ/K SXVDCJ/K SXVD3CJ/K SXVD3CJ/K ater tank volume 3 3 /3/5 /3/5 /3/5 /3/5 Electric heater power Cool water inlet inch() Screw thread spec of pipe Hot water outlet Diameter H inch() φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ φ φ6 6 φ6 6 Packaged D H 63x68x63 63x68x63 648x78x75 648x78x75 68/77 7/8 8/9 87/97 oading quantity 4'GP/4'HQ 75/ 75/ 63/63 63/63 Floor Debugging High efficiency Quiet function Selfdiagnosis ide voltage range Comprehensive protection Compact design ater tank volume Electric heater power Screw thread spec Cool water inlet of pipe Hot water outlet Diameter H Packaged D H oading quantity 4'GP/4'HQ inch() inch() SXVDCJ/M SXVDCJ/M SXVD3CJ/M SXVD3CJ/M 3 3 3/4/5 3/4/5 3/4/5 3/4/ φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ φ φ6 6 φ /77 7/8 8/9 87/97 75/ 75/ 63/63 63/63 Note: Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) φ/ Female BSP(.7) Integral installation, convenient and costsaving. Twostage compression technology is adopted to greatly improve the system's performance, especially for improving energy efficiency of heating in low ambient temperature. Smart dualtemperature detection control technology. Solar kit linkage function is added to automatically control water heating of solar energy, energysaving and ecofriendly. High outlet water temperature and wide water temperature range, meeting the demands of various terminals. Item ater ater Side eaving ater Temperature( 7~5 5~6 4~8(ater Tank Temperature) Heat Source/User Side Environment Dry Bulb Temperature( ~48 ~ ~45 Note: hen operating conditions are out of the range listed above, please contact Gree. 79/8

6 IR TO TER * 3 * * 4 * 3 Power Input* * 4 /COP* * 5 * * 6 * 5 Power Input* * 6 /COP* Sanitary water temperature Sound pressure level Connecting pipe diameter s ( D H) Notes:. Capacites and power inputs are based on the following conditions: conditions. Indoor ater Temperature 3/8. Outdoor ir Temperature DB/4B. conditions. Indoor ater Temperature 3/. Outdoor ir Temperature 7DB/6B. Standing piping length 7.5m. 3. For floor cooling. 4. For floor heating. 5. For fan coil unit. 6. For fan coil or radiator. Gas iquid Packaged 4'GP oading quantity 4'HQ inch() inch() GRSCQ8.Pd/NaCK GRSCQPd/NaCK GRSCQPd/NaCM GRSCQ4Pd/NaCM 4VPh5Hz 3845V3Ph5Hz / / ~ φ5/8(5.9) φ3/8(9.5) 39x4x89 463x438x 48/ / / ~ φ5/8(5.9) φ3/8(9.5) 39x4x89 463x438x 48/6 8 8 Split ater Heater / / ~ φ5/8(5.9) φ3/8(9.5) x38x438 48x433x575 5/ Capacites and power inputs are based on the following conditions: conditions. Indoor ater Temperature /7. Outdoor ir Temperature DB/4B. conditions. Indoor ater Temperature 4/45. Outdoor ir Temperature 7DB/6B. Standing piping length 7.5m / / ~ φ5/8(5.9) φ3/8(9.5) x38x438 48x433x575 5/ Gree split type water heater offers you with sufficient hot water, ensuring an warm and comfortable life to each family. Its installation is convenient and it is applicable for a family of 3 to 5 members. Safety and ecofriendly ater and electricity are separated to avoid possible electric shock. ithout possible toxicities of CO, user s safety can be ensured. No pollutant is released during operation, so there is no damage to the environment. Reliable and durable dopting special compressor, the unit is resistant to high temp. and pressure. The water tank adopts advanced stainless steel inner container with magnesium sticks. The entire unit is with multiple protection functions to ensure long lifespan of the system. Easy installation ithout limitation of environment, the unit can be installed in kitchen, garage, stock room or basement. It is also suitable for skyscrapers, villa, and so on. Easy operation ater temperature can be. ater supply can be on or off depending on water temperature and water consumption, so that hot water can be supplied at any time. Unit on/off can be by user according to requirements (the unit will stop once water temperature reaches the ting point). Running of unit in electric platykurtosis is possible to reduce electricity fee. Intelligent defrosting The unit with antifreezing and intelligent defrosting functions can efficiently prevent freezing and frosting. llday use The unit can make and supply hot water all day in despite of night, overcast and rainy days. Outdoor Unit Rated Rated Input Power oad Profile COP Energy Efficiency Class ater Energy Efficiency Time (7/6, 555 C) Maximum Input Power Circuit Breaker Outlet ater Temperature Power Supply Insulation evel Protection of Ingression Name Refrigerant Charge s xdxh Package s xdxh Max. Pipe ength/height Gross/Net eight Sound Power evel 3 Operating Range h C m C GRSS3.5PdG/NaK (Electric Heater) 6 Default: 55 C, C~55 C 4V~5Hz I PX4 R4.4 84x3x59 948x363x / ~45 C Notes: Value obtained with the following conditions: Outdoor temperature: C DB/5 C B; ater tank temperature (start/end): 5 C /55 C. Value obtained with an air temperature of 7 C and a water inlet at, as per EN647, (EU) No 84/3. 3. Value obtained as per EN Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. 5. GRSS3.G/NbK is fixedfrequency model with refrigerant of R34a;GRSS3.5PdG/NaK is inverter model with refrigerant of R4. ater Tank Selfdiagnosis Compact design Clock display Intelligent defrosting Easier maintainability Child lock Power Supply for Electric Heater Input Power for Electric Heater Max. Operation Pressure s(xdxh) Package s(xdxh) ater Tank Gross/Net eight Outer Size of Connection Pipe MPa SXTDCJ/K 85 V4V~5Hz x46x x583x45 88/75 Φ6, Φ9.5 Note: Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. 8/8

7 IR TO TER Integral ater Heater The unit is with new integrated structure, concise design, and centrifugal type wind system design, which can connect air inlet pipe and air outlet pipe. This unit is applicable for garage, storage room, balcony and other household locations. Controller XK64 Controller ZF5 a Power Input oad Profile COPDH ater Energy Efficiency Energy Efficiency Class Refrigerant Refrigerant Charge Volume Circuit Breaker Refrigerant Design Pressure Tank Design Pressure Max. Operation Pressure Time (7/6555 C) Running mbient Temperature Outwater Temperature ir Flow Rate vailable Static Pressure Max. ength of ir Connection Sound Pressure evel(heating) Sound Power evel(heating) Volume ater Pipline s( D H) Net ight/gross eight oading ater Inlet Pipe ater Outlet Pipe Drainage Pipe Packaged 4'GP/4'HQ MPa MPa MPa h C C Pa m inch inch inch GRS.4/D7NbK GRS.5/TD5NbK GRS.5/TDNbK * * * X.6 5 R34a ~ /39 8/ R34a / / / x56x76 73x77x845./9. 48/ R34a / / / x56x3 73x77x.5/.5 48/48 Note: Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. *:This model can not installed with air duct. *:This model can installed with air duct. High efficiency Intelligent defrosting Energy Saving ide operation range switch Clock display Child lock 4 hour timer Safety and ecofriendly ater and electricity are separated to avoid possible electric shock. ithout possible toxicities of CO, user s safety can be ensured. No pollutant is released during operation, so there is no damage to the environment. Reliable and durable dopting special compressor, the unit is resistant to high temp. and pressure. The water tank adopts advanced stainless steel inner container with magnesium sticks. The entire unit is with multiple protection functions to ensure long lifespan of the system. Easy installation ithout limitation of environment, the unit can be installed in garage, stock room or basement. It is also suitable for skyscrapers, villa, and so on. Installation and maintenance is convenient for its no cycle waterway system. Easy operation ater temperature can be. ater supply can be on or off depending on water temperature and water consumption, so that hot water can be supplied at any time. Unit on/off can be by user according to requirements (the unit will stop once water temperature reaches the ting point). Running of unit in electric platykurtosis is possible to reduce electricity fee. Intelligent defrosting The unit with antifreezing and intelligent defrosting functions can efficiently prevent freezing and frosting. llday use The unit can make and supply hot water all day in despite of night, overcast and rainy days. 83/84

8 IR TO TER Direct & Circulating ater Heater It is a kind of heat pump water heater that could supply coercial hot water, which is applicable for operation in ambient temperature from 6 to 46. Direct Rated water heating capacity Rated water supply l/h GRSDm3/NaM GRSDm4/NaM 4 86 GRSDm6/NaM 6 3 COP ater temperature range /3845/5 3/3845/5 3/3845/5 mode Circulating Rated power input Max power input ater heating ater heating STTUS FUNC PRM Hwater level Next ired controller Z63K Sound Pressure level ( D H) Packaged oading quantity 4'GP/4'HQ /5 6/ /86 6/ /378 / Circulating GRSCm8/NaM GRSCm36/NaM GRSCm53/NaM Rated water heating capacity Rated water supply l/h COP ater temperature range /38~45/5 3/38~45/5 3/38~45/5 Rated power input ater heating Max power input ater heating GRSDm3/NaM GRSDm4/NaM GRSDm6/NaM GRSCm8/NaM GRSCm36/NaM GRSCm53/NaM Sound Pressure level ( D H) Packaged oading quantity 4'GP/4'HQ /6 6/ /77 6/ /376 / Notes:. Testing conditions of above data: mbient temperature DB/5 B; entering/leaving water temperature: 5 /55 ; power supply: 3/38/5Hz;. Considering the system reliability and various water temperature demands for different ambient temperature, we have limited the highest water temperature. The curve is shown as below. High efficiency ow temperature heating Compact design Intelligent defrosting ide voltage range Easier maintainability Energy Saving Comprehensive protection 3. The above products are not for EU. 4Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. ide operation range Modular operating 75 Curve of highest water temperature for different ambient temperature 75 Curve of highest water temperature for different ambient temperature 7 (7, 7) (.7) 7 Grounding protection: The system is with multiple grounding protection to avoid electric leakage. Overcurrent protection: The system will turn off automatically in overload, in order to ensure safety of the system. High pressure protection: Protection in overhigh pressure ensures the reliability of the system. uto protection when the system pressure is low. High discharge temperature protection: It avoid the influence of overhigh discharge temperature to ensure the lubrication effect of compressor lubricant. ater pressure protection: It restricts the lowest water pressure to ensure the reliability of the system. ater flow protection: It detects the water flow to avoid no water operation. ntifreezing protection: It is with multiple antifreezing design to ensure reliable operation of the system in ultralow ambient temperature. ater temperature 65 (5, 59) (5, 54) (7, 56) (5, 56) Direct heating leaving water temperature Tank Temperature (45, 6) (45, 5) mbient temperature( Direct ) ater temperature 65 6 (5, 53) (7, 58) Tank Temperature 5 5 (7, 6) (5,6) mbient temperature(circulating ) (45,53) /86

9 IR TO TER PX Series Multifunctional irtowater Heat Pump PX Series Multifunctional irtowater Heat Pump adopting the world s first compressor with three cylinder two stage and variable volume designed by GREE and the latest system, structure, control system, has cooling, heating and domestic water function. It can run stably in ultra low temperature() with high outlet temperature 6. It can be connected with floor radiation coil, heating radiator and fancoil Outdoor unit * Power Input * /COP * * Power Input * /COP * Sound Pressure evel Refrigerant Connecting pipe diameter Connecting pipe diameter (xdxh) oading Gas iquid ater inlet pipe ater outlet pipe Package 4 GP 4 HQ GRSCQPd/NaFK(O) ~4// / / R x4x 998x458x55 33/ GRSCQ4Pd/NaFK(O) ~4// / / R x4x 998x458x55 33/ GRSCQ6Pd/NaFK(O) ~4// / / R x4x 998x458x55 33/ Outdoor Unit Indoor Unit 3 XKY Notes *. The values are based on the following conditions: ) : Indoor ater Temperature 3/8; Outdoor ir Temperature DB/4B; ) : Indoor ater Temperature 3 /; Outdoor ir Temperature 7DB/6B; 3) Standing piping length 5m. *. The values are based on the following conditions: ) : Indoor ater Temperature /7; Outdoor ir Temperature DB/4B; ) : Indoor ater Temperature 47/55 ; Outdoor ir Temperature 7DB/6B; 3) Standing piping length 5m. Indoor unit Intelligent defrosting ide operation range Quiet function switch ow temperature heating High efficiency Energy Saving ide voltage range Turbo function capacity with full load under 5. Ultra heating under ambient temperature at with outlet temperature at 6. Intelligent water antifreezing detection technology is adopted to greatly improve the chiller s antifreezing performance. Multi objective control energy saving technology, automatic adjust the optimal operation state of the unit based on indoor temperature. Rated power input eaving water temperature Pump Sound Pressure evel Connecting pipe diameter Connecting pipe diameter (xdxh) oading * * * * Nr.of speed ater flow limit Gas iquid ater inlet pipe ater outlet pipe Package 4 GP 4 HQ PM GRSCQPd/NaFK(I) GRSCQ4Pd/NaFK(I) GRSCQ6Pd/NaFK(I) ~4//5 ~4//5 ~4// RS5/7.5 RS5/7.5 RS5/7.5 8/477 8/477 8/ x5x38 88x5x38 88x5x38 x65x4 x65x4 x65x4 5/64 5/64 5/ Mode Heatling Heat Source Side Temperature( 6~48 ~8 User Side Temperature( 7~ 3~6 87/88

10 SCRO CHIER SCRO CHIER Inverter Mini Chiller (Split ) Inverter Mini Chiller Mini Chiller Modular ircooled Scroll Chiller 89/9

11 SCRO CHIER Inverter Mini Chiller (Split ) Inverter mini chiller, is a king of smallsize aircooled chiller that canbe connectd to all sorts of fan coil unit to realize cooling and heating. It can be used on the temperature range of ~48 8/ /4 Z55J Heat Pump HR8Pd/NaBK HRPd/NaBK HRPd/NaBK HR4Pd/NaBK 8 4 ng 4 6 /COP 3.8/3.3.78/3.6.86/ /3. Power Supply // ng inverter rotary compressor Quan ty Refrigerant Charge volume l/s Buildin chilled pump power input m Buildin expansion verssle volume Chilled water outlet/inlet screw thread spec inch G G G G Sound Pressure level (xdxh) Outling 98x47x788 98x47x788 94x46x8 94x46x8 Package 97x477x937 97x477x937 83x573x973 83x573x973 8/9 8/9 3/3 3/3 oading quan ty 4'GP/4'HQ 74/8 74/8 69/7 69/7 Note: The product models are under development and not for EU. Intelligent defrosting ide operation range ow temperature heating High efficiency dopt R4, which is an ecofriendly refrigerant that is harmless to ozone layer and contains no Cl. It complies with the national requirement on energy conservation and emission reduction. dopt brandnew efficient canister type heat exchanger with better heat exchange effect and higher energy efficiency; it is lighter and more compact; wallmounted indoor unit to follow the market trend; hard to form scales, more reliable. Userfriendly design, with energysaving mode, absence mode, silent mode and floor coissioning function, for intelligent and high quality user experience. From components to system and control, they have been designed very carefully and passed strict tests. Together with selfdiagnosis and malfunction diagnosis, the unit can run stably and reliably in its operating range. ater side (water temperature) ir side (outdoor temperature) Item Nominal operating condition Operating range Nominal operating condition Operating range Inlet() Outlet() Outlet() I/O difference() DB() DB() ~ ~8 9/9

12 SCRO CHIER Inverter Mini Chiller Inverter mini chiller, is a king of smallsize aircooled chiller that can be connected to all sorts of fan coil units to realize cooling and heating. It can be used on the temperature range of ~48 Mini Chiller Mini Chiller is a kind of unit that makes cold water and hot water and then achieves air conditioning through the terminals selected by user. It is widely adopted in departments, villas, restaurants, shops, etc. ired controller Z63Q Inner groove copper Selfdiagnosis Comprehensive protection Memory function inverter control regulates water temperature precisely. Integral installation is convenient and costsaving. Precise system pressure control improves the antifreezing function of the system. Twostage compression technology is adopted to greatly improve the system's performance. ater side (water temperature) ir side (outdoor temperature) Item Nominal operating condition Operating range Nominal operating condition Operating range Inlet() Outlet() Outlet() I/O difference() DB() B() DB() 7 7~5 ~ 4 ~48 Quality motor Compact design Intelligent defrosting Easier maintainability ~6 ~ 7 6 ~ Heat pump HR8Pd/NaK HRPd/NaK HRPd/NaM HR4Pd/NaM ng 8 4 /COP 3./3.5 3./3.4 3./3.7 3./3.4 Power Supply ~4//5 38~45/3/ ng Rotary Rotary Rotary Rotary Quan ty Refrigerant Charge volume l/s Pump power input Buildin chilled water pump m Buildin expansion vessel volume Chilled water outlet/inlet screw thread spec inch Sound Pressure level (*D*H) Outling 39x4x89 39x4x89 4x365x4 4x365x4 Package 463x438x 463x438x 443x433x x433x575 4/55 4/55 94/9 94/9 oading quan ty 4'GP/4'HQ 8/8 8/8 43/43 43/43 Comprehensive protection High efficiency ide operation range The appearance of unit is beautiful and installation of unit is convenient. The indoor unit and outdoor unit of split type unit can be installed in combination or split type. Meanwhile, the height of indoor unit is only 88. The integral type unit adopts upinclined air outlet design with high flexibility. The unit s cooling and heating performance will not be affected by seasonal wind and installation place thanks to this design, especially suitable for installation site with limited floor height and building distance; The unit is equipped with water pump, expansion tank, automatic water makeup valve and safety valve. Installation of expansion water tank is not needed, which greatly reduces installation cost; Main control system adopts advanced computer control system for comprehensive control to the unit. Meanwhile, multiple points control function is available to control the on/off of master unit in any room, or achieve priority control to unit by ting main control point in any room. 93/94

13 SCRO CHIER Item Heat pump HR8ZNaM HRZNaM HR.5ZNaM HR5ZNaM /COP Bulidin chilled water pump Bulidin expansion vessel volume Chilled water outlet/inlet screw thread spec Indoor unit Outdoor unit Outer diameter of connection pipe oading quantity Standard controller Pump power input Delivery lift Sound pressure level ( D H) Packaged Sound pressure level ( D H) Nominal operating condition Packaged iquid pipe Gas pipe 4'GP/4'HQ ired ater side (water temperature) l/s m inch inch() inch() /.73.7/.73.9/ /3. 3/3845/5 3/3845/5 3/3845/5 3/3845/ Scroll Scroll Scroll "Female BSP "Female BSP "Female BSP /96 84/96 84/ / /3 5/9 φ/(.7) φ3/4(9.5) Operating range φ/(.7) φ3/4(9.5) 5/5 63/64 Z63 ir side (outdoor temperature) Nominal operating condition φ/(.7) φ3/4(9.5) 63/64 Operating range Inlet() Outlet() Outlet() I/O difference() DB() B() DB() 7 7~5 ~ ~6 ~ Scroll "Female BSP / /9 φ/(.7) φ3/4(9.5) 63/64 /COP Bulidin chilled water pump Heat pump Pump power input Delivery lift Bulidin expansion vessel volume Chilled water outlet/inlet screw thread spec Sound pressure level ( D H) Packaged 3/3845/5 3/3845/5 3/3845/5 3/3845/5 3/3845/5 l/s m inch oading quantity 4'GP/4'HQ Standard controller ired HRSNaM HR5SNaM HRSNaM HR45SNaM HRSM/NaM.5 5.5/ Scroll "Female BSP /387 5/ / Scroll "Female BSP /39 5/ / Scroll /"Female BSP /69 / Z3 Notes:. The product models are not for EU.. Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives / Scroll /"Female BSP /765 / / Scroll /"Female BSP /6 / Z63C Notes:. The specification is tested under the connection pipe of 7.5 meters.. The product models are not for EU. 95/96

14 SCRO CHIER Modular ircooled Scroll Chiller It is a kind of aircooled scroll chillers that can be connected to all sorts of fan coil units to realize cooling/heating for civil or industrial buildings. D Series 65/8 3/6 49/8 Display panel Z63C steps /COP ater side heat exchanger ir side heat exchanger Heat pump / Fan type and quantity Total fan air flow Total fan motor power Sound pressure level ( D H) Package( D H) Net/Gross/Operating weight oading quantity 4'GP/4'HQ l/s l/s SQRF65M/NaDM SQRF8M/NaDM SQRF3M/NaDM SQRF6M/NaDM SQRF49M/NaDM* SQRF8M/NaDM* 6/65 7/79.5 /3 45/7 49/75 8/ 7.6/8.48.9/.6 34./ / / / /3.9.76/.94.84/.93.74/3.4.95/3.5.85/ V3Ph5Hz Constant Speed Scroll Direct Starting Dry Expansion DN65 DN8 DN luminum Fincopper Tube xialflow/ /745/84 / xialflow/ /797/87 / xialflow/ X65X3 36X73X3 /3/447 6/ xialflow/ X65X3 36X73X3 54/59/654 6/ xialflow/ X6X45 44X6X45 985/995/384 / xialflow/ X6X45 44X6X45 378/388/366 / Notes: Golden fin condenser Inner groove copper Modular structure Comprehensive protection Selfdiagnosis Easier maintainability Memory function 4 hour timer. This product model is under development. Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives.. This model is not fit for EU. Running condition realtime display. ow startup current thanks to power delay control design. Use Utype heat exchange tube to improve the heatexchange efficiency of the complete unit; Special equalizing plate design of shell and tube: the distribution of refrigerant is more even for improving the heatexchanging efficiency of the complete unit. Main module patent: any unit can be as main module via wired controller. Up to 6 units (6/7) or 8 units (/45) can be integrated freely to get a max capacity of 6 thanks to modular design. uto antifreezing function under heating mode when the unit is switched off. Item ater side (water temperature) ir side (outdoor temperature) Nominal operating condition Operating range Nominal operating condition Operating range Inlet() Outlet() Outlet() I/O difference() DB() B() DB() 7 5~5.5~6 5~ ~5.5~ ~4 97/98

15 SCRE CHIER SCRE CHIER Highefficiency Heat Pump ircooled Screw Chiller Highefficiency Modular ircooled Screw Chiller Highefficiency atercooled Screw Chiller 99/

16 SCRE CHIER Highefficiency Heat Pump ircooled Screw Chiller Gree Highefficiency ircooled Screw Chiller adopts Gree brand aircooled heat pump specialized compressor, flooded type shellandtube design and a totally enclosed structure. Featuring high efficiency, high reliability and low noise, this air conditioning equipment can provide cool water in suer and hot water in winter. It can be combined with fan coil unit, floor ceiling unit, packaged unit or other kinds of terminals. a Heat pump steps /COP ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight oading quantity 4'GP/4'HQ SBGRF3MH/NbM ,5~ V 3N5Hz DN x6 77x6.5x6 367x5x55 375x33x55 457/46/466 / SBGRFMH/NbM ,5~ V 3N5Hz SBGRF4MH/NbM ,5~ V 3N5Hz 3 3 Semihermetic screw compressor Start Delta Start Flooded DN DN5 luminum Fincopper Tube x6 x8 77x6 77x8.5x6.5x8 367x5x55 489x5x55 375x33x55 497x33x55 474/478/48 567/57/5783 / / SBGRF47MH/NbM ,5~ V 3N5Hz DN5 x8 77x8.5x8 489x5x55 497x33x55 578/58/5896 / Display panel ZF3M Golden fin condenser Inner groove copper Modular structure Comprehensive protection Selfdiagnosis ongdistance monitoring Memory function Highly efficient and energy saving; Gree's efficient aircooled heat pump specialized compressor; Heat pump flooded type shellandtube design; Vshaped structure for fins, efficient heat exchange design; Seamless connectivity on site, cooling capacity can be enlarged infinitely; Totally enclosed structure, patent low noise and low vibration design, safe and comfortable. 4 hour timer Intelligent defrosting High efficiency Heat pump steps /COP ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight oading quantity 4'GP/4'HQ SBGRF5MH/NbM ,5~ V 3N 5Hz DN5 x 77x.5x 6x5x55 69x33x55 67/675/6844 / SBGRF58MH/NbM , 5~ V 3N 5Hz 7 7 SBGRF65MH/NbM ,5~ V 3N 5Hz 9 9 Semihermetic screw compressor Start Delta Start Flooded DN5 DN5 luminum Fincopper Tube x x 77x 77x.5x.5x 6x5x55 734x5x55 69x33x55 74x33x55 697/7/79 855/859/87 / / SBGRF7MH/NbM ,5~ V 3N 5Hz DN5 x 77x.5x 734x5x55 74x33x55 885/889/97 / Note: The product models are not for EU. Item Heatling ater side(water temperature) ir side(outdoor temperature) Nominal operating condition Operating range Nominal operating condition Operating range Inlet() Outlet() Outlet() I/O difference() DB() B() DB() 7 5~5.5~8 8~ ~5.5~ ~4 /

17 SCRE CHIER Heat pump steps /COP ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight oading quantity 4'GP/4'HQ m3/h m3/h SBGRF76MH/NbM ,5~ V 3N 5Hz DN5 x4 77x4.5x4 856x5x55 864x33x55 99/994/98 / SBGRF8MH/NbM ,5~ V 3N 5Hz DN5 x4 77x4.5x4 856x5x55 864x33x55 97/975/994 / SBGRF86MH/NbM ,5~ V 3N 5Hz 5 5 Semihermetic screw compressor Start Delta Start Flooded DN5 luminum Fincopper Tube x6 77x6.5x6 978x5x55 986x33x55 9/95/8 / SBGRF95MH/NbM ,5~ V 3N 5Hz DN5 x6 77x6.5x6 978x5x55 986x33x55 /5/434 / SBGRF5MH/NbM ,5~ V 3N 5Hz DN x8 77x8.5x8 x5x55 8x33x55 38/46/68 / Highefficiency Modular ircooled Screw Chiller It is a kind of Highefficiency aircooled screw chillers that can be connected to all sorts of fan coil units to realize cooling/heating for civil or industrial buildings. a Heat pump steps /COP ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight oading quantity 4'GP/4'HQ m3/h m3/h SBGRF6MH/NbM , 5~ V 3N 5Hz xdn5 x 77x.5x 3x5x55 3x33x55 /33/33 / SBGRF8MH/NbM , 6.7~ V 3N 5Hz DN5+DN5 x 77x.5x 345x5x55 3x33x55 58/59/636 / SBGRF4MH/NbM 4 SBGRF5MH/NbM ,.5~ 6.5,.5~ V 3N 5Hz 38V 3N 5Hz Semihermetic screw compressor Start Delta Start 4 4 Flooded DN5 DN5 luminum Fincopper Tube x4 x6 77x4 77x6.5x4.5x6 467x5x55 589x5x55 475x33x55 597x33x55 77/778/ /88/95 / / SBGRF65MH/NbM ,.5~ V 3N 5Hz DN5 x8 77x8.5x8 7x5x55 7x33x55 967/975/63 / Golden fin condenser Inner groove copper Comprehensive protection Selfdiagnosis Memory function 4 hour timer ongdistance monitoring High efficiency Intelligent defrosting Thanks to V type fin structure, unit features small refrigerant pressure loss and high efficiency. ith flooded type shellandtube design, evaporating temperature is increased, hence improving the heat exchanging efficiency and energy efficiency. Unit adopts low noise fan blades and specialized compressor noise reduction device, therefore sound level falls to 5 lower than the nd generation. Due to the totallyenclosed design, its appearance is harmonious and nicelooking. Modular structure Note: The product models are not for EU. ater side (water temperature) ir side (outdoor temperature) Item Nominal operating condition Operating range Nominal operating condition Operating range Inlet() Outlet() Outlet() I/O difference() DB() B() DB() 7 5~5.5~8 8~5 3/4

18 SCRE CHIER steps only SBGF3 MH/NbM 3 9 5,5~ SBGF MH/NbM* ,5~ SBGF4 MH/NbM ,5~ SBGF47 MH/NbM* ,5~ SBGF5 MH/NbM ,5~ SBGF58 MH/NbM* , 5~ steps only SBGF94 MH/NbM* ,5~ SBGF95 MH/NbM ,5~ SBGF5 MH/NbM* ,5~ SBGF6 MH/NbM , 6.7~ SBGF6 MH/NbM* , 5~5 SBGF8 MH/NbM* ,6.7~ ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight only oading quantity 4'GP/4'HQ 3. 38V 3N~5Hz DN x6 77x6.5x6 367x5x55 375x33x55 43/47/43 / V 3N~5Hz DN x6 77x6.5x6 367x5x55 375x33x55 43/436/446 / V 3N~5Hz 38V 3N~5Hz 3 44 Semihermetic screw compressor Start Delta Start Flooded DN5 DN5 luminum Fincopper Tube x8 x8 77x8 77x8.5x8.5x8 489x5x55 489x5x55 497x33x55 497x33x55 499/53/59 54/545/558 / / 3. 38V 3N~5Hz DN5 x 77x.5x 6x5x55 69x33x55 598/6/6 / 3. 38V 3N~5Hz DN5 x 77x.5x 6x5x55 69x33x55 6/64/6 / ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight only oading quantity 4'GP/4'HQ V 3N~5Hz DN5 x6 77x6.5x6 978x5x55 986x33x55 997//69 / V 3N~5Hz DN5 x8 77x8.5x8 x5x55 8x33x55 8/3/486 / V 3N~5Hz 38V 3N~5Hz 3 Semihermetic screw compressor Start Delta Start 3 Flooded DN DN5+DN5 luminum Fincopper Tube x8 x 77x8 77x.5x8.5x x5x55 345x5x55 8x33x55 3x33x55 5/3/ /345/3637 / / V 3N~5Hz DN 5x8 654x8.8x8 x5x55 8x33x55 5/3/373 / V 3N~5Hz DN5+DN5 x 77x.5x 345x5x55 3x33x55 447/455/4759 / steps only SBGF63 MH/NbM* , 5~ SBGF65 MH/NbM ,5~ SBGF7 MH/NbM* ,5~ SBGF75 MH/NbM ,5~ SBGF8 MH/NbM* ,5~ SBGF86 MH/NbM ,5~ steps only SBGF3 MH/NbM ,.5~ SBGF4 MH/NbM* ,.5~ SBGF5 MH/NbM* ,.5~ SBGF5 MH/NbM ,.5~ SBGF65 MH/NbM* ,.5~ SBGF7 MH/NbM* ,.5~ ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight only oading quantity 4'GP/4'HQ V 3N~5Hz DN5 5x 654x.8x 6x5x55 69x33x55 68/6/634 / V 3N~5Hz DN5 x 77x.5x 734x5x55 74x33x55 744/748/7589 / V 3N~5Hz 38V 3N~5Hz 6 3 Semihermetic screw compressor Start Delta Start Flooded DN5 DN5 luminum Fincopper Tube x x4 77x 77x4.5x.5x4 734x5x55 856x5x55 74x33x55 864x33x55 8/86/88 8/839/857 / / V 3N~5Hz DN5 x4 77x4.5x4 856x5x55 864x33x55 9/95/99 / V 3N~5Hz DN5 x6 77x6.5x6 978x5x55 986x33x55 93/97/933 / ater side heat exchanger ir side heat Total fan air flow exchanger Total fan motor power ( D H) Package( D H) Net/Gross/Operating eight only oading quantity 4'GP/4'HQ V 3N~5Hz xdn5 x4 77x4.5x4 467x5x55 475x33x55 488/496/578 / V 3N~5Hz xdn5 x4 77x4.5x4 467x5x55 475x33x55 584/59/657 / V 3N~5Hz 38V 3N~5Hz Semihermetic screw compressor Start Delta Start 4 4 Flooded xdn5 xdn5 luminum Fincopper Tube x6 x8 77x6 77x8.5x6.5x8 589x5x55 7x5x55 597x33x55 7x33x55 74/7/ /73/789 / / V 3N~5Hz xdn5 x8 77x8.5x8 7x5x55 7x33x55 847/855/8839 / V 3N~5Hz xdn5 5x4 654x4.8x4 467x5x55 475x33x55 75/759/786 / Note: The product models with * are not for EU. Note: The product models with * are not for EU. 5/6

19 SCRE CHIER a Highefficiency atercooled Screw Chiller This series of water cooled screw chiller adopts the advanced semienclosed dualscrew compressor, plus R34a ecofriendly refrigerant and vertical oil separator, to guarantee long time stable operation, high efficiency and energy saving; it is widely applicable to various kinds of office buildings, hospitals, schools, shopping centers and also applicable for cooling of production processing. capacity steps IPV R Refrigeration oil Charge volume Condenser dimension (xdxh) Net/Operating weight SBG7HE/NbM /38/ CPISolest7 m o c / m 3 /h m o c / m 3 /h x88x85 3/45 SBG3HE/NbM /38/ CPISolest x88x85 33/45 SBGHE/NbM SBG38HE/NbM /38/5 3/38/ Semihermetic twin screw comp. Y 5 CPISolest7 CPISolest7 3 3 Flooded type shell and tube evaporator Flanged connection Vertical type shell and tube condenser Flanged connection 375x365x x365x959 75/9 78/95 SBG43HE/NbM /38/ CPISolest x365x959 8/95 SBG46HE/NbM /38/ CPISolest x465x4 3/5 Comprehensive protection Selfdiagnosis Precision water temperature control thanks to stepless capacity adjustment from 5~(single comp) or.5~(dual comp). Higher heat exchange efficiency thanks to flooded evaporating method. Higher efficiency under partial load thanks to paralleling operation design. High reliability oil return technology to avoid compressor damage from oil lack. Precision and stable volume adjusting thanks to orifice plus EXV throttle method. utomatic operation and energy saving operation makes an easier management. Operating condition of nominal cooling (water temperature) Chilled water water Memory function Easier maintainability Operating range (water temperature) Chilled water water capacity steps IPV R Refrigeration oil Charge volume Condenser dimension (xdxh) Net/Operating weight SBG49HE/NbM /38/ CPISolest7 3 m o c / m 3 /h m o c / m 3 /h x465x4 337/5 SBG55HE/NbM /38/ CPISolest x465x4 34/36 SBG6HE/NbM SBG67HE/NbM SBG7HE/NbM /38/5 3/38/5 3/38/ Semihermetic twin screw comp. Y CPISolest7 CPISolest7 CPISolest Flooded type shell and tube evaporator Flanged connection Vertical type shell and tube condenser Flanged connection 34x58x 383/45 34x58x 388/4 3485x53x85 55/55 SBG76HE/NbM /38/ CPISolest x53x85 533/56 SBG85HE/NbM /38/ CPISolest x53x85 538/57 Inlet() Outlet() Inlet() Outlet() Outlet() I/O difference() Inlet() I/O difference() 7 3 4~5.5~8 8~ 3.5~8 Note: The product models are not for EU. 7/8

20 SCRE CHIER capacity steps IPV R Refrigeration oil Charge volume Condenser dimension (xdxh) Net/Operating weight m o c / m 3 /h m o c / m 3 /h SBG9HE/NbM /38/ CPISolest x6x 6/67 SBG98HE/NbM /38/ Semihermetic twin screw comp. Y 4+4 CPISolest7 3+3 Flooded type shell and tube evaporator Flanged connection Vertical type shell and tube condenser 98 7 Flanged connection 4x6x 638/675 SBGHE/NbM /38/ CPISolest x6x 64/68 capacity steps IPV R Refrigeration oil Charge volume Condenser dimension (xdxh) Net/Operating weight m o c / m 3 /h m o c / m 3 /h SBG75HE/NbM /38/ CPISolest x58x 393/45 SBG75HE/NbM /38/ CPISolest x58x 398/4 SBGH/NbM /38/ Screw Y 36 CPISolest Flange Condenser Flange 455x8x 779/85 SBG3H/NbM /38/ CPISolest x8x 785/83 SBG4H/NbM /38/ CPISolest x8x 79/84 SBG48H/NbM /38/ CPISolest x8x 795/845 Note: The product models are not for EU. 9/

21 CENTRIFUG CHIER CENTRIFUG CHIER CE Series Fixedspeed Centrifugal Chiller CVE Series Permanent Magnet Synchronous Inverter Centrifugal Chiller CC Series Magnetic Bearing Inverter Centrifugal Chiller /

22 CENTRIFUG CHIER CE Series Fixedspeed Centrifugal Chiller new generation of fixedspeed centrifugal chiller, with twostage compression technology, is highly efficient, energysaving, safe and reliable. a capacity steps IPV R Refrigeration oil Charge volume Net/Gross/Operating weight oading quantity 4'GP/4'HQ m o c / /s m o c / /s Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) CE3GHG 3 ~ DN DN 8 385x8x 395x95x45 68/7/745 CE3GHG 46 4 ~ DN DN 8 385x8x 395x95x45 7/74/775 CE3MH4HH CE3MH3HH ~ ~ Centrifugal Y No.68 synthetic fatty oil 5 5 Flooded DN5 DN5 Shell and Tube DN5 DN x85x3 43x85x3 44x9x55 44x9x55 73/78/8 75/8/84 CE33MHJH ~ DN DN5 8 45x9x37 44xx6 785/8/88 CE33MHJH 6 ~ DN DN5 8 45x9x37 44xx6 8/86/9 Quiet function Comprehensive protection Memory function ongdistance monitoring High efficiency Energy saving function Twostage compression Twostage compressor air makeup technology and economizer are adopted to improve efficiency by 5~6 compared with onestage cooling circulation system. Rotation speed of compressor is reduced, operation reliability is improved and lifespan is prolonged. Meanwhile, surge margin is wide and operation range is wide. Variablearea diffuser is adopted to effectively improve surge margin and system operation range, and reduce noise and vibration. ith integrated startup cabinet and wire connection in the factory, user only needs to provide power cord, so wire connection during installation is simplified and floor area of startup cabinet is reduced. Semienclosed motor and helical refrigerant ejecting cooling technology is adopted to not only reduce the risk of refrigerant and lubricant leakage, but also prevent heat dissipation in machine room, reducing the cooling device cost and operation cost. New heat exchanger specially designed for centrifugal chiller contributes to even distribution of refrigerant, rational temperature field and heat exchange rate improvement; meanwhile, the heat exchanger adopts highefficiency heat exchange tube for reducing heat transfer resistance and improving the system s cooling capacity and energy efficiency ratio. Userfriendly touch screen is adopted for convenient operation. Highperformance digital signal processing and intelligent control technology is adopted. Operating condition of nominal cooling (water temperature) Chilled water water Inlet() Outlet() Inlet() Outlet() Operating range (water temperature) Chilled water water Outlet() I/O difference() Inlet() I/O difference() 5~5.5~8 ~ 3.5~8 capacity steps IPV R Refrigeration oil Charge volume Net/Gross/Operating weight oading quantity 4'GP/4'HQ m o c / /s m o c / /s Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) CE4PIEKIE ~ DN DN xx39 47xx6 96//7 CE4PIDKID 46 7 ~ DN DN xx39 47xx6 985//95 CE4PICKIC CE4PIBKIB ~ ~ Centrifugal Y No.68 synthetic fatty oil 6 6 Flooded DN5 DN5 Shell and Tube DN5 DN xx39 455xx39 47xx6 47xx6 /6/3 /95/55 CE5PIKI ~ DN DN xx39 47xx6 8/3/5 CE5QJCMJD ~ DN DN xx6 5x3x85 /6/345 3/4

23 CENTRIFUG CHIER capacity steps IPV R Refrigeration oil Charge volume Net/Gross/Operating weight oading quantity 4'GP/4'HQ m o c / /s m o c / /s Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) CE5QJBMJC ~ DN DN xx6 5x3x85 5/85/375 CE5QJMJB 6 ~ DN DN xx6 5x3x85 5/3/4 CE5RJMJ CE5RJMJ ~ ~ Centrifugal Y 95 Shell and Tube 975 No.68 synthetic fatty oil 8 8 Flooded DN DN x3x7 5x3x95 6/3756/ DN DN x3x7 5x3x95 349/49/55 CE6SKNQKN 49 ~ DN DN 85 55x53x88 56x9x3 66/7/87 soft starting CE6SKMQKM ~ DN DN 85 55x53x88 56x9x3 7/76/95 capacity steps IPV R Refrigeration oil Charge volume Net/Gross/Operating weight oading quantity 4'GP/4'HQ m o c / /s m o c / /s Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) CE7UNSNG 7384 ~ /3/ DN DN x3x33 64x3x3 6/68/93 CE73UMSMG 77 ~ /3/ DN DN x3x33 64x3x3 66/74/3 CE73USG CE6UN4SN4G CE6UN3SN3G ~ ~ ~ /3/5 /3/5 /3/ Centrifugal Direct starting DN DN x3x33 64x3x3 69/77/34 No.68 synthetic fatty oil Flooded DN5 Shell and Tube DN x46x85 8x336x336 3/33/ DN DN x46x85 8x336x336 33/34/3695 CE6UNSNG ~ /3/ DN DN x66x95 8x336x336 34//385 CE6UNSNG 55 3 ~ /3/ DN DN x66x95 8x336x336 /36/395 capacity steps IPV R Refrigeration oil Charge volume Net/Gross/Operating weight oading quantity 4'GP/4'HQ m o c / /s m o c / /s Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) CE6SKQK 49 4 ~ soft starting DN DN 85 55x53x88 56x9x3 74/8/96 CE6TKNRKNG ~ /3/ DN DN x75x3 58x3x3 86/94/5 CE63TKMRKMG CE63TKRKG CE7TNRG ~ ~ ~ /3/5 /3/5 /3/ Centrifugal Direct starting 45 5 No.68 synthetic fatty oil DN DN x75x3 58x3x3 9/98/5 Flooded DN Shell and Tube DN x75x3 58x3x3 95/3/ DN DN x75x3 64x3x33 /43/65 CE7TMRPG ~ /3/ DN DN x75x3 64x3x33 4/48/68 CE7TROG 73 ~ /3/ DN DN x75x3 64x3x33 45/53/745 Notes:. bove model selection is applicable to the condition in which leaving chilled water temperature is 6.7 and entering cooling water temperature is CE6UN4SN4G~CE6UNSNG adopt independent dualsystem structure. 3. bove water flow is indicated according to RI 55/595; IPV is the test value obtained based on the working condition specified in RI 55/ Scale factors of chilled water and cooling water are.8 m²/ / and m² / respectively. 5. For compressor using direct starter, starting current7 times rated current; for compressor using star delta starter, starting current3.5 times rated current; for compressor using soft starter, starting current4. times rated current; direct starter takes 4 seconds, star delta starter takes 3~6 seconds, soft starter takes seconds; power factor For special working condition, please contact Gree s local sales agent. 7. Standard unit s water side bearing pressure is.mpa;.6mpa is an available option. 8. The unit s performance parameters may be changed without prior notice due to product improvement. For the specific parameters, please refer to product nameplate. 9. The product models are not for EU. 5/6

24 CENTRIFUG CHIER CVE Series Permanent Magnet Synchronous Inverter Centrifugal Chiller It adopts highefficiency DC inverter centrifugal compressor with internationally leading coefficient of performance. It provides highefficiency and stable operation, and can be connected to all sorts of fan coil units to realize cooling for large civil and industrial buildings. ide operation range Comprehensive protection Memory function ongdistance monitoring a High efficiency capacity adjustment range IPV R Refrigeration oil Charge volume Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) Net/Gross/Operating weight oading quantity 4'GP/4'HQ m./' /s m./' /s CVEHG4FG4 CVEHG3FG3 CVEHGFG CVEHGFG CVE3GHG CVE3MH4HH ~ DN DN 8 377x59x85 39x75x5 55/545/ ~ DN DN 8 377x59x85 39x75x5 54/554/ ~ No.68 synthetic fatty oil 3 4 Flooded DN DN 8 377x59x85 39x75x5 55/58/65 3 ~ Centrifugal Variable Frequency Drives DN Shell and Tube DN 8 377x59x85 39x75x5 57/6/ ~ DN DN 8 385x8x 395x95x 6/645/ ~ DN DN5 8 43x85x5 445x95x 68/7/765 Energy saving function s it adopts highefficiency motor directdriven twostage impellers with simpler structure and more reliable operation, the size and weight of compressor is only 4 of the conventional compressor with the same cooling capacity. It adopts highefficiecy permanent magnet synchronous inverter motor, whose power is over 4 and rotation speed is over 8rp. Meanwhile, the helical refrigerant ejecting cooling technology is adopted to ensure highefficiency operation of the motor. The design of impeller and diffuser is optimized for achieving highefficiency operation of compressor in various loads. It adopts patented sensor control technology to control the position of motor precisely and improve the reliability. It adopts the unique diffuser with wide blade spacing to achieve highefficiency recycle of pressure. Twostage compressor air makeup technology and economizer are adopted to improve efficiency by 5~6 compared with onestage cooling circulation system. Rotation speed of compressor is reduced, operation reliability is improved and lifespan is prolonged. Meanwhile, surge margin and operation range are wide. Userfriendly touch screen is adopted for convenient operation, precise control and stable output. Inlet() Operating condition of nominal cooling (water temperature) Chilled water Outlet(). 6.7 Directdriven impeller Integrated inverter Twostage compression Inlet() 9.4 water Outlet() 34.9 Chilled water 5~5.5~8 Operating range (water temperature) ~ water Outlet() I/O difference() Inlet() I/O difference() 3.5~8 capacity adjustment range IPV R Refrigeration oil Charge volume Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) Net/Gross/Operating weight oading quantity 4'GP/4'HQ m./' /s m./' /s CVE3MH3HH CVE4MHJH CVE4MHJH CVE5PIEKIE CVE5PIDKID CVE5PICKIC ~ DN DN x85x5 445x95x 688/78/ ~ DN DN x9x 44xx45 77/86/86 6 ~ No.68 synthetic fatty oil 4 4 Flooded DN DN x9x 44xx45 78/87/ ~ Centrifugal Variable Frequency Drives DN5 Shell and Tube DN xx3 47xx5 886/936/ ~ DN DN xx3 47xx5 897/947/ ~ DN DN xx3 47xx5 97/977/4 7/8

25 CENTRIFUG CHIER capacity adjustment range IPV R Refrigeration oil Charge volume Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) Net/Gross/Operating weight oading quantity 4'GP/4'HQ m./' /s m./' /s CVE5PIBKIB CVE5PIKI CVE6QJCMJD CVE6QJBMJC CVE6QJMJB CVE6RJMJ 83 8 ~ DN DN xx3 47xx5 937/987/ ~ DN DN xx3 47xx5 948/998/ ~ No.68 synthetic fatty oil 5 5 Flooded DN DN xx5 5x37x75 73/3/ ~ Centrifugal Variable Frequency Drives DN3 Shell and Tube DN xx5 5x37x75 86/36/5 6 ~ DN DN xx5 5x37x75 /5/5 Notes:. bove model selection is applicable to the condition in which leaving chilled water temperature is 6.7 and entering cooling water temperature is Standard unit s water side bearing pressure is.mpa;.6mpa is an available option. 3. Scale factors of chilled water and cooling water are.8m² / and m² / respectively. 4. bove water flow is indicated according to RI 55/595; IPV is the test value obtained based on the working condition specified in RI 55/ For compressor using inverter starter, starting currentrated current; power factor is The unit s performance parameters may be changed without prior notice due to product improvement. For the specific parameters, please refer to product nameplate. 7. The product models are not for EU ~ DN DN x3x6 5x6x85 67/7/3 CC Series Magnetic Bearing Inverter Centrifugal Chiller Gree CC series magnetic bearing inverter centrifugal chiller adopts the magnetic bearing compressor for aeronautic industry, which achieves oilfree operation of cooling system, avoids complicated lubricant system and greatly improves system s reliability. This series can be widely adopted in hotels, office buildings, etc. Quiet function Memory function It adopts magnetic bearing to achieve oilfree operation and reduce the heat exchange influence of lubricant The system adopts flooded heat exchange design and buildin subcooler in condenser. Impellers directly driven by the motor with gearless design, improving the reliability of the system. ith advanced and reliable microcomputer control system, powerful group control modules and building counication interface. Userfriendly touch screen is adopted for convenient operation, precise control and stable output. Multiple protection function. Noise of this entire unit is lower than the traditional ones. a Comprehensive protection ongdistance monitoring capacity adjustment range IPV R Condenser Sound pressure level (Max.) (xdxh) Package(xDxH) Net/Gross/Operating weight oading quantity 4'GP/4'HQ m./' /s m./' /s CCFE5EE5 ~ DN DN5 78 3x4x9 x36x 695/995/ CCFE4EE ~ DN DN5 78 3x4x9 x36x 339/369/37 CCFE3EE ~ Centrifugal Variable Frequency Drives DN DN5 78 3x4x9 x36x /38/39 CC3GEFE ~ Flooded DN5 Shell and Tube DN5 78 3x8x9 x4x 3738/438/4 CC3GEFE 73 ~ DN DN5 78 3x8x9 x4x 395/45/4 CC3HG5GG ~ DN DN x59x95 39x75x5 4796/596/53 9/

26 CENTRIFUG CHIER capacity adjustment range IPV R Condenser capacity adjustment range IPV R Condenser Sound pressure level (Max.) Sound pressure level (Max.) (xdxh) Package(xDxH) Net/Gross/Operating weight oading quantity 4'GP/4'HQ (xdxh) Package(xDxH) Net/Gross/Operating weight oading quantity 4'GP/4'HQ m./' /s m./' /s m./' /s m./' /s CC3HG4GG ~ DN DN x59x95 39x75x5 4833/533/5 CC4MHHH ~ DN DN5 8 45x85x5 445x95x 64/69/75 CC3HG3GG ~ DN DN x59x95 39x75x5 494/534/545 CC3HGGG 55 3 ~ Centrifugal Variable Frequency Drives DN DN x59x95 39x75x5 58/548/56 CC3HGGG 3 ~ Flooded DN Shell and Tube DN x59x95 39x75x5 546/5646/57 CC5MHJH ~ Centrifugal Variable Frequency Drives 6 Flooded DN5 Shell and Tube DN5 8 45x9x 44xx45 764/84/855 CC4MH4HH 46 4 ~ DN DN 8 43x85x5 395x95x 63/68/75 CC5MHJH 6 ~ DN DN5 8 45x9x 44xx45 77/8/865 CC4MH3HH ~ DN DN5 8 43x85x5 445x95x 64/69/75 Inlet() Operating condition of nominal cooling (water temperature) Chilled water Outlet(). 6.7 Control System ineup Chiller ongdistance monitoring software BMS accessories* (mocbus) Other modules Control system ired remote controller Display panel Touch screen* Gree C Eudemon 9* 3 Counication module Optoelectronic isolated converter Patch board Optoelectronic isolated signal multiplier Z63 Z3 Z63C ZF3M* ZGDJ* CM7 GZ/(M) CM8 GM8/(M) FE3/(M) ME38/E(M) RS3 RS4\485 RS4\485 Z3 Inlet() 9.4 Product series water Outlet() 34.9 Modulor chiller Split serirs Integral series D series Chilled water 5~5.5~8 Operating range (water temperature) ~ water Outlet() I/O difference() Inlet() I/O difference() ircooled Screw chiller Screw chiller atercooled screw chiller Centrifugal chiller Inverter Centrifugal Chiller Notes means standard, means optional. * ith BMS(modbus) function. * BMS interface is equipped. * 3 For aircooled scroll chiller, if longdistance monitoring software Gree Eudemon 9 is selected, the counication module ME38/E(M) shall be selected also. The selection shall refer to actual models. 3.5~8 Magnetic suspension inverter centrifugal chiller(cc series) Notes:. bove model selection is applicable to the condition in which leaving chilled water temperature is 6.7 and entering cooling water temperature is Standard unit s water side bearing pressure is.mpa;.6mpa is an available option. 3. Scale factors of chilled water and cooling water are.8m² / and m² / respectively. 4. bove water flow is indicated according to RI 55/595; IPV is the test value obtained based on the working condition specified in RI 55/ For compressor using inverter starter, starting currentrated current; power factor is The unit s performance parameters may be changed without prior notice due to product improvement. For the specific parameters, please refer to product nameplate. 7. The product models are not for EU. /

27 TERMIN TERMIN Fan Coil Unit ir Curtain 3/4

28 TERMIN Fan Coil Unit Concealed Ceiling It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Rows/High ESP FP34H/GHK FP5H/GHK FP68H/GHK FP85H/GHK FPH/GHK FP36H/GHK FP7H/GHK FP4H/GHK ir flow volume(h/m/) ESP Pa 45/338/5 65/9/3 57/48/5 347/5/68 75/563/375 44/33/ 93/698/ /4/74 /85/55 647/458/34 4/5/7 84/68/4 / /.3 3./ / /4.9 5./ /8. Power system /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 Input l/s ater system (cooling) Ft.G Sound pressure level ( D H) Package 68x5x 773x33x65 8x5x 89x33x65 9x5x 99x33x65 x5x 9x33x65 8x5x 7x33x65 38x5x 47x33x65 ater inlet & outlet (inner groove) inch() 4.5/9. 7/.9 8.9/4.8/6..9/ /37.5 diameter Condensed water drain (outer groove) inch() oading quantity 4'GP/4'HQ 38/44 73/364 55/34 5/3 /8 68/4 Optional ired remote control uxury wired controller:kpk/cd controller:kp Note: This parameter is obtained based on the test standard of Eurovent and under Pa static pressure with circle bellows & filter. 7/75/85 /75/5 7./9. /~4/ x5x 65x33x65 34./4.6 /4 /5/ 76/88/588./ /~4/ x5x 7x33x65 38/ /84 3 Rows Inner groove copper ashable filter Quiet function Multi fan speed Compact design Thanks to optimized air flue design that greatly improve the fan efficiency and lower the operation noise. Flexible air inlet/outlet directions, meet different installation requirements. ashable filter is optional when equipped with air return box. Nominal test condition (temperature) Item DB () B () Inlet () Outlet () ir flow volume(h/m/) ESP Power system ater system Sound pressure level ( D H) / Input Package diameter oading quantity Optional (cooling) ater inlet & outlet (inner groove) Condensed water drain (outer groove) 4'GP/4'HQ ired remote control Pa l/s Ft.G inch() inch() FP34S/GHK 37/78/85 8/63/9./.4 /~4/ x5x 773x33x65 4.9/9.6 38/44 FP5S/GHK 57/48/85 3/5/68 3./3.7 /~4/ x5x 89x33x65 7.4/.3 73/364 FP68S/GHK 7/54/6 44/38/ 4./4.8 /~4/ x5x 99x33x65 9.3/4.4 55/34 FP85S/GHK 87/653/4 5/384/56 4.8/5.5 /~4/ x5x 9x33x65.3/6.7 /765/5 6/45/3 5.9/6.6 /~4/ x5x 7x33x65.7/8.3 5/3 /8 68/4 uxury wired controller:kpk/cd controller:kp FPS/GHK FP36S/GHK FP7S/GHK FP4S/GHK 36//68 8/6/4 7.6/8.9 /~4/ x5x 47x33x65 3.9/36.9 6//8 94/76/47 8.8/. /~4/ x5x 65x33x /4 /4 9/45/65 8/838/559.4/. /~4/ x5x 7x33x65 38/ /84 Rows/Standard FP34/GHK FP5/GHK FP68/GHK FP85/GHK FP/GHK FP36/GHK FP7/GHK FP4/GHK ir flow volume(h/m/) ESP Pa 37/78/85 8/63/9 57/48/85 3/5/68 7/54/36 44/38/ 87/653/4 5/384/56 /765/5 6/45/3 36//68 8/6/4 /.75/..9/ /4. 4.3/ /6 6.7/8 Power system /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 Input l/s ater system (cooling) Ft.G Sound pressure level ( D H) Package 68x5x 773x33x65 8x5x 89x33x65 9x5x 99x33x65 x5x 9x33x65 8x5x 7x33x65 38x5x 47x33x65 ater inlet & outlet (inner groove) inch() 4.5/9. 7/.9 8.9/4.8/6..9/ /37.5 diameter Condensed water drain (outer groove) inch() oading quantity 4'GP/4'HQ 38/44 73/364 55/34 5/3 /8 68/4 Optional ired remote control uxury wired controller:kpk/cd controller:kp Note: This parameter is obtained based on the test standard of Eurovent and under Pa static pressure with circle bellows & filter. 6//8 94/76/47 7./9 /~4/ x5x 65x33x65 34./4.6 /4 9/45/95 8/838/559 /.9 /~4/ x5x 7x33x65 38/ /84 ir flow volume(h/m/) ESP Power system ater system Sound pressure level ( D H) / Input Package diameter (cooling) ater inlet & outlet (inner groove) Condensed water drain (outer groove) Pa l/s Ft.G inch() inch() FP34HS/GHK 45/338/5 65/9/3.5/.8 /~4/ x5x 773x33x65 4.9/9.6 FP5HS/GHK 57/48/85 3/5/68 3.3/3.8 /~4/ x5x 89x33x65 7.4/.3 FP68HS/GHK 75/563/375 44/33/ 4./5. /~4/ x5x 99x33x65 9.3/4.4 FP85HS/GHK 93/698/ /4/74 4.9/5.7 /~4/ x5x 9x33x65.3/6.7 oading quantity 4'GP/4'HQ 38/44 73/364 55/34 5/3 /8 68/4 Optional ired remote control uxury wired controller:kpk/cd controller:kp Note: This parameter is obtained based on the test standard of Eurovent and under Pa static pressure with circle bellows & filter. FPHS/GHK FP36HS/GHK FP7HS/GHK FP4HS/GHK /85/55 647/485/34 6./6.9 /~4/ x5x 7x33x65.7/8.3 4/5/7 84/68/4 7.8/9 /~4/ x5x 47x33x65 3.9/36.9 7/75/85 /75/5 9/.9 /~4/ x5x 65x33x /4 /4 /5/ 76/88/588.5/.4 /~4/ x5x 7x33x65 38/ /84 5/6

29 TERMIN 3+ Rows FP34HT/BHK FP5HT/BHK FP68HT/BHK FP85HT/BHK FPHT/BHK FP36HT/BHK FP7HT/BHK FP4HT/BHK ir flow volume(h/m/) ESP Pa 43/33/5 53/9/6 64/48/3 376/8/88 74/555/37 4/36/8 9/683/455 5/4/68 4/78/5 6/459/36 6//8 94/76/47 /.45/ / / /6. 6./ /9.9 Power system /4/5 /4/5 /4/5 /4/5 /4/5 /4/5 Input l/s ater system (cooling) Ft.G Sound pressure level ( D H) Package 88x5x45 9x75x6 x5x45 3x75x6 3x5x45 5x75x6 x5x45 3x75x6 37x5x45 39x75x6 76x5x45 78x75x6 ater inlet & outlet (inner groove) inch() 9/.5.5/7 5/9.5 7/ / 43.5/48.5 diameter Condensed water drain (outer groove) inch() oading quantity 4'GP/4'HQ 3/48 7/36 5/336 7/37 98/64 56/8 Optional ired remote control uxury wired controller:kpk/cd controller:kp Note: This parameter is obtained based on the test standard of Eurovent and under Pa static pressure with circle bellows & filter. 98/485/99 65/874/58./.5 /4/ x5x45 94x75x6 47/53 44/9 /575/5 /96/68./.9 /4/ x5x45 94x75x6 47/53 44/9 Fan Coil Unit Caste Quiet function Multi fan speed Compact design Selfdiagnosis Inner groove copper Builtin drain pump ashable filter Thanks to optimized air flue design that greatly improve the fan efficiency and lower the operation noise. Four directions airflow that makes an even temperature and humidity distribution. moisture auto cleaning after power off to avoid mildew. Forced high speed fan operation under emergency condition. nticold function 4 Rows ir flow volume(h/m/) ESP Power system ater system Sound pressure level ( D H) / Input Package (cooling) Pa l/s Ft.G FP34HF/BHK 43/33/5 53/9/6.65/3. /4/ x5x45 37x5x45 9/.5 FP5HF/BHK 64/48/3 376/8/88 3.8/4.4 /4/ x5x45 76x5x45.5/7 FP68HF/BHK 74/555/37 4/36/8 5./5.45 /4/ x5x45 9x5x45 5/9.5 FP85HF/BHK 87/653/4 5/384/56 5.7/6.5 /4/ x5x45 9x5x45 7/3.5 FPHF/BHK 4/78/5 6/459/36 7./7.3 /4/ x75x6 39x75x6 3.5/ FP36HF/BHK 6//8 94/76/47 8.9/9.5 /4/ x75x6 78x75x6 43.5/48.5 ater inlet & outlet (inner groove) inch() diameter Condensed water drain (outer groove) inch() oading quantity 4'GP/4'HQ 3/48 7/36 5/336 7/37 98/64 56/8 Optional ired remote control uxury wired controller:kpk/cd controller:kp Note: This parameter is obtained based on the test standard of Eurovent and under Pa static pressure with circle bellows & filter. FP7HF/BHK 98/485/99 65/874/58./.3 /4/ x75x6 94x75x6 47/53 44/9 FP4HF/BHK /575/5 /96/68./3 /4/ x75x6 94x75x6 47/53 44/9 Nominal test condition (temperature) Item DB () B () Inlet () Outlet () pipe & 4way ir flow volume(h/m/) / Power System Input l/s ater System Power System Ft.G Sound prssure level Body (xdxh) Package Panel (xdxh) Package ater inlet & outlet Connetion pipe size inch() Condensed water drain inch() oading quantity Standard controller Optional controller 4'GP/4'HQ iredless remote ired remote FP5XD/K /3.4 /~4/ x594x9 776x73x85 /4 67x67x5 67x67x6 7/ 3/4 5 39/376 YBFXFN Z4EB FP68XD/K /4. /~4/ x594x9 776x73x85 /4 67x67x5 67x67x6 7/ 3/4 5 39/376 YBFXFN Z4EB FP85XD/BTE 8/665/59 47/385/ /5.4 /~4/ x84x9 96x96x57 5/33 95x95x85 3x3x8 7/ 3/4 33 3/47 YBFXFN Z4EB FPXD/BTE 94/77/67 553/453/394 5./6. /~4/ x84x9 96x96x57 5/33 95x95x85 3x3x8 7/ 3/4 33 3/47 YBFXFN Z4EB FP5XD/BTE 9/86 64/56/447 6./6.9 /~4/ x84x4 96x96x3 7/ 95x95x85 3x3x8 7/ 3/ /33 YBFXFN Z4EB ir flow volume(h/m/) / Power System Input l/s ater System Power System Ft.G Sound prssure level Body (xdxh) Package Panel (xdxh) Package ater inlet & outlet Connetion pipe size inch() Condensed water drain inch() oading quantity Standard controller Optional controller 4'GP/4'HQ iredless remote ired remote FP4XD/BTE 4/6/ 83/68/ /8.4 /~4/ x84x4 96x96x3 7/ 95x95x85 3x3x8 7/ 3/4 33 7/33 YBFXFN Z4EB FP6XD/BTE 5// 88/76/ /9. /~4/ x84x4 96x96x3 7/ 95x95x85 3x3x8 7/ 3/4 33 7/33 YBF(XFN) Z4EB FP8XD/BTE 64/36/ 964/8/76 9.5/.5 /~4/ x84x3 96x96x394 3/4 95x95x85 3x3x8 7/ 3/ / YBF(XFN) Z4EB FPXD/DK(E) 7/43/5 /84/676./.7 /~4/ x84x3 96x96x394 3/4 95x95x85 3x3x8 7/ 3/ / YBF(XFN) Z4EB 7/8

30 TERMIN Fan Coil Unit Floor Ceiling Fan Coil Unit all Mounted Inner groove copper ashable filter nticold function Quiet function uto clean Multi fan speed Compact design Thanks to optimized air flue design that greatly improve the fan efficiency and lower the operation noise. Reasonable airflow that makes an even temperature and humidity distribution. The unit is with air valve for more reliable operation. Nominal test condition (temperature) Item DB() B() Inlet() Outlet() Inner groove copper ashable filter nticold function Quiet function uto clean Multi fan speed Selfdiagnosis Compact design Thanks to optimized air duct design that greatly improve the fan efficiency and lower the operation noise. The fan will be operated only if the chilled water inlet temperature is lower than the ting value to avoid warm air under cooling condition. Item Nominal test condition (temperature) DB() DB() DB() DB() Floor Ceiling FP34ZDKE FP5ZDKE FP68ZDKE FP85ZDKE FPZDKE FP36ZDKE FP7ZDKE FP4ZDKE ir flow volume(h/m/) 4/3/ 5/4/3 68/55/45 69/57/485 9/756/6 3/854/7 8/6/85 94/5/5 /76/4 3//8 4/34/65 46/3/85 5/445/3 66/5/4 59/74/5 4/88/ Power System /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 /~4/5 Input ater System Sound prssure level (cooling) l/s Ft.G X38X X38X X38X X38X X88X X88X X88X X88X695 (xdxh) Package 963X333X X333X X333X X333X845 47X5X739 47X5X739 77X333X845 77X333X845 6/33 6/33 6/33 6/33 34/4 34/4 48.5/ /57 Connetion pipe ater inlet & outlet inch() 3/4'(9.5) 3/4'(9.5) 3/4'(9.5) 3/4'(9.5) 3/4'(9.5) 3/4'(9.5) 3/4'(9.5) 3/4'(9.5) diameter Condensed water drain inch() 5/8'(5.6) 5/8'(5.6) 5/8'(5.6) 5/8'(5.6) 5/8'(5.6) 5/8'(5.6) 5/8'(5.6) 5/8'(5.6) oading quantity Standard controller Optional controller 4'GP/4'HQ iredless remote ired remote 4/67 YBF Z4EB 4/67 YBF Z4EB 4/67 YBF Z4EB 4/67 YBF Z4EB /44 YBF Z4EB /44 YBF Z4EB /7 YBF Z4EB /7 YBF Z4EB allmounted ir flow volume(h/m/) Power System ater System Input Sound prssure level (xdxh) Connetion pipe diameter oading quantity Standard controller Optional controller ir flow volume(h/m/) Power System ater System Power System ater inlet & outlet Condensed water drain 4'GP/4'HQ iredless remote ired remote Input Sound prssure level (xdxh) Connetion pipe diameter oading quantity Standard controller Optional controller Power System ater inlet & outlet Condensed water drain 4'GP/4'HQ iredless remote ired remote l/s Ft.G inch() inch() l/s Ft.G inch() inch() FP34B/DKE 36/3/8 /89/66.3 /~4/ x8x75 95x55x5 /.5 Φ/(.7) Φ5/8(5.6) 765/85 YBF(XFN) Z4EB FP68BB3/K(E) 68/6/53 4/34/ /~4/ xx98 x85x38 /6. Φ/(.7) Φ5/8(5.6) 595/67 YBF(XFN) Z4EB FP5B/DKE 55/4/36 34/43/6.5.8 /~4/ x8x75 95x55x5 /.5 Φ/(.7) Φ5/8(5.6) 765/85 YBF(XFN) Z4EB FP85BB3/K(E) 85/78/66 5/47/ /~4/ xx98 x85x38 /6. Φ/(.7) Φ5/8(5.6) 595/67 YBF(XFN) Z4EB FP68B/DKE 68/59/53 4/348/ /~4/ xx98 x85x38 /6 Φ/(.7) Φ5/8(5.6) 595/67 YBF(XFN) Z4EB FP34B3/BK 36/3/8 /89/ /~4/ x8x75 95x55x5 8.8/.8 Φ/(.7) Φ5/8(5.6) 765/85 YBF(XFN) Z4EB FP85B/DKE 85/7/6 5/4/ /~4/ xx98 x85x38 3/7 Φ/(.7) Φ5/8(5.6) 595/67 YBF(XFN) Z4EB FP5B3/BK 5/43/367 3/43/ /~4/ x8x75 95x55x5 8.8/.8 Φ/(.7) Φ5/8(5.6) 765/85 YBF(XFN) Z4EB FP34BB3/K(E) 36/3/9 /89/ /~4/ x8x75 95x55x5 /.5 Φ/(.7) Φ5/8(5.6) 765/85 YBF(XFN) Z4EB FP68B3/BK 68/59/53 4/348/ /~4/ xx98 x85x38.8/4.8 Φ/(.7) Φ5/8(5.6) 595/67 YBF(XFN) Z4EB FP5BB3/K(E) 55/39/34 34/43/6.4.6 /~4/ x8x75 95x55x5 /.5 Φ/(.7) Φ5/8(5.6) 765/85 YBF(XFN) Z4EB FP85B3/BK 83/78/66 488/47/ /~4/ xx98 x85x38.8/4.8 Φ/(.7) Φ5/8(5.6) 595/67 YBF(XFN) Z4EB 9/3

31 TERMIN ir Curtain The air curtain adopts cross flow blower to generate high speed air flow downward, that be installed upward side of the entrance door or window, to isolate the indoor air from the outdoor air and reduce the loss of indoor cool air, also prevent the insects and dust from entering the indoor environment. Control System ineup Control system Product series Caste type Floor ceiling type all mounted type ir curtain YBF ireless remote controller ZY6* * Mechanical FCU controller Z54 Digital thermostat uxury KPK KP ongdistance monitoring software Gree C Eudemon 9* FE3/(M ) ME37/E(M) ashable filter Quiet function Compact design Easier maintainability BMS accessories Counication module (modbus) DQ34* 3 ZJ Optimized crossflow fan and good performance motor are adopted. Micro processor controlling with high reliability and long service life. Optoelectronic isolated converter RS3RS4\485 nticorrosion thanks to twoside painted electrogalvanized metal case. High quality galvanized steel casing with doublesided plastic spray processing, high anticorrosion. Other modules Optoelectronic isolated signal multiplier RS4\485 Good strength structure provides powerful airflow. Integrated electric components, easy maintenance. High performance cross flow fan blade with 3Doptimized streamlined. Notes: means standard, means optional. * The pictures of unit and wireless remote controller please refer to the actual product. * If longdistance monitoring software Gree Eudemon 9 is selected, the counication module ME37/E(M) shall be selected also. The selection shall refer to actual models. *3 DQ34 including wired remote controller Z4EB and Counicaition module ZJ, so if DQ34 is selected, the wired remote controller Z54 is not necessary to select. ME37/E(M) is not necessary also. Item Dry bulb temperature of inlet air orking condition parameters 5~4 ir flow volume Sound pressure level (H/) ( D H) Net weight /Gross weight oading quantity Setting height Standard FM.59K V/Hz 3/5 3 m /h db () 59 9x5x93 Package 5x7x56 6/8 4 GP HQ 954 m.3~3 ired remote controller ZY6 FM.5K 3/ x5x93 x7x56 / ~3 ZY6 Note: Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. 3/3

32 SPECIIZED C SPECIIZED C Marine ir Conditioner Close Control ir Conditioner Elevator ir Conditioner 33/34

33 SPECIIZED C Marine ir Conditioner It is a kind of sea water source C that is widely used in yachts and boats. /COP Input current Sound pressure level Heat Pump Btu/h Btu/h /3.8 4// CYR6/NaT /.93 3// /3.8 4// CYR4/NaCT /3.6 3// Display Panel Z5 ir flow volume (H) ( D H) Package Condenser pipe diameter 4'GP oading quantity 4'HQ Fan motor supply air outlet diameter inch() x465x33 663x558x / (9.4) x465x33 663x558x / (9.4) x54x x638x44 6.5/ (9.4) x54x x638x44 6.5/ (9.4) Golden fin condenser Inner groove copper ashable filter Quiet function Selfdiagnosis Memory function Compact design Switch 36 degree air blowing. Outlay electric box for easy installation & maintenance. ow startup current thanks to power delay control design. Forced operation available for emergency situation. CD display of operation status. Highly anticorrosion special spray processing on the complete unit. NickelCopper tubeintube heat exchanger for sea water side. llcopper fined tube heat exchanger for air side. Only one PCB for the entire control and minimize cable connections, with higher reliability and also easier maintenance. Universal for both 5Hz and 6Hz. /COP Input current ( D H) Sound pressure level ir flow volume (H) Package Condenser pipe diameter 4'GP oading quantity 4'HQ Fan motor supply air outlet diameter Heat Pump CYR5/NaCT CYR9/NaCT CYR/NaT Btu/h Btu/h inch() /.64 4// x48x95 594x493x36 5.5/ (9.5) /.73 3// x48x95 594x493x36 5.5/ (9.5) /.5 4// x48x3 683x53x36 8./ (9.5) /.85 3// x48x3 683x53x36 8./ (9.5) /.9 4// x44x33 68x533x / (9.4) /3.7 3// x44x33 68x533x / (9.4) /36

34 SPECIIZED C Close Control ir Conditioner* It is a kind of air cooled split C that is widely used in equipment room, machinery room, etc. to precisely control the temperature and humidity. Energy saving function Rapid and safe startup. Selfdiagnosis Modular structure Easier maintainability Flexible installation and several air outlet directions to meet different installation requirements. Modular design, up to 4 units could be freely integrated to get a max. capacity of 6. Normal / 5 capacity 4/7 (total/sensible) 4/45 6/5 Rated input / Rated current / capacity Humidifying ESP Rated capacity Range of temp. controlling and precision Range of humidity and precision Indoor units Outdoor units Normal ir flow volume Sound pressure level ( D H) Package Net weight/gross weight ir flow volume Sound pressure level ( D H) Package Net weight/gross weight Connecting pipe iquid/gas Method of connection oading quantity 4'GP/4'HQ /h Pa m 3 /h Set m 3 /h JKFD5C/NaM JKFD5QS/NaM 3/38/5 6.5/3.8 7./ /4. 7.6/4.5./.8./3.8 7./ / ~8± 4~6±5 JKFD5C/NaM(I) JKFD5QS/NaM(I) /6 57/585 JKFD3/NaM(O) JKFD3/NaM(O) x33x634 89/5 φ/6 Flaredfitting Joint /7 7/7 JKFD5SX/NaM./3.8 7./.97 JKFD5SX/NaM(I) /55 JKFD3/NaM(O) 7/7 ongdistance monitoring software (optional) FE3/(M) Compact design ongdistance monitoring JKFD4C/NaM JKFD4QS/NaM JKFD4SX/NaM 3/38/5 39.4/36. 4./ / / /. 4.4/ ~8± 4~6±5 JKFD4C/NaM(I) JKFD4QS/NaM(I) JKFD4SX/NaM(I) /755 66/69 66/69 JKFD9/NaM(O) JKFD9/NaM(O) 9 JKFD9/NaM(O) x33x634 /5 φ6/9 Flaredfitting Joint /6 6/6 6/6 Class Characteristics of Units System ir Supply System System Humidifying System Outdoor Units Connecting Pipe Item Total / Sensible (/ 5) Total / Sensible (4/7) Total / Sensible (4/45) Total / Sensible (6/5) Rated Humidifying ir Flow Volume External Static Pressure coustic Noise of Indoor Units Range of Temp. Controlling and Precision Range of Humidity and Precision Power Supply Condenser Refrigerant Throttling Method Indoor Units Fan ir Filter Heater Humidifier Mode of Control The of Indoor Units idth Depth Height Net eight The of Outdoor Units Condensate Fan of Drive coustic Noise of Outdoor Units idth Depth Height Net eight iquid ine of Refrigerants Gas Pipe of Refrigerants Method of Connection Unit JKFD5CR/NaE JKFD5QSR/NaE JKFD7CR/NaM JKFD7QSR/NaM Notes:.This unit is designed, manufactured and inspected according to National Standard GB/T Tested ambient temperature of cooling capacity: indoor side dry bulb temp. 4, web bulb temp.7outdoor side dry bulb temp.. 3. Noise was measured according to relavant standard of halfanechoic room, so in actual operation, noise may increase as ambient temperature changes. 4. Specific parameters shall be referred to unit nameplate and subject to change without prior notice. 5.mbient temperature range for operation48 6. ll the above models can realize modular operation. 7. ny other special requirements, please contact us. /h pa of Drive (unit) (unit) 5.3/ /5. 5.4/ / ± 46±5 V 5Hz Hermetic Scroll Inner Screw Thread Pipe with Hyrophilic Film luminum Fin Inner Screw Thread Pipe with Hyrophilic Film luminum Fin R4 Electric Expansion Valve ow Noise and Centrifugal Externalrotor Direct Drive Plate Filter (G4) Electric infrared utomatic Control by Mainboard JKFD5CR/NaE(I) JKFD5QSR/NaE(I) JKFD5P/NaE(O) ow Noise xial Direct Drive Φ9.5 Φ Flared Joint 6.8/5.8 7./6.5 7./ / ± 46±5 38V 3N 5Hz Hermetic Scroll Inner Screw Thread Pipe with Hyrophilic Film luminum Fin Inner Screw Thread Pipe with Hyrophilic Film luminum Fin R4 Electric Expansion Valve ow Noise and Centrifugal Externalrotor Direct Drive Plate Filter (G4) Electric infrared utomatic Control by Mainboard JKFD7CR/NaM(I) JKFD7QSR/NaM(I) JKFD7P/NaE(O) ow Noise xial Direct Drive Φ9.5 Φ Flared Joint Notes:. The cooling capacity was tested when the outdoor temperature was as follows: Drybulb temperature was ; etbulb temperature was 4.. The noise value was tested in the semianechoic chamber but the actual value will be a little higher for the change of ambient temperature. 3. The temperature range of running environment is between 48 37/38

35 SPECIIZED C Class Characteristics of Units System ir Supply System System Humidifying System Outdoor Units Connecting Pipe Item JKFD5CR/NaM JKFD5QSR/NaM JKFDCR/NaM JKFDQSR/NaM Unit Total / Sensible (/ 5) 4.8/3.5 9./8. Total / Sensible (4/7) 5./3.6./8.4 Total / Sensible (4/45) 4.9/ /8.8 Total / Sensible (6/5) 6.6/5..3/9.9 7 Rated Humidifying /h 4 4 ir Flow Volume m3/h External Static Pressure Pa coustic Noise of Indoor Units Range of Temp. Controlling and Precision 78± 78± Range of Humidity and Precision 46±5 46±5 Power Supply 38V 3N 5Hz 38V 3N 5Hz Hermetic Scroll Hermetic Scroll Inner Screw Thread Pipe with Hyrophilic Inner Screw Thread Pipe with Hyrophilic Film luminum Fin Film luminum Fin Inner Screw Thread Pipe with Hyrophilic Inner Screw Thread Pipe with Hyrophilic Condenser Film luminum Fin Film luminum Fin Refrigerant R4 R4 Throttling Method Electric Expansion Valve Electric Expansion Valve ow Noise and Centrifugal Externalrotorotor ow Noise and Centrifugal External Fan Indoor Units of Drive Direct Drive Direct Drive ir Filter Plate Filter (G4) Plate Filter (G4) Heater Electric Electric Humidifier infrared infrared Mode of Control utomatic Control by Mainboard utomatic Control by Mainboard The of Indoor Units JKFD5CR/NaM(I) JKFD5QSR/NaM(I) JKFDCR/NaM(I) JKFDSR/NaM(I) idth Depth Height Net eight The of Outdoor Units JKFD5P/NaM(O) JKFDP/NaM(O) Condensate Fan ow Noise xial ow Noise xial of Drive Direct Drive Direct Drive coustic Noise of Outdoor Units idth 4 4 Depth Height 3 3 Net eight iquid ine of Refrigerants (unit) Φ Φ6 Gas Pipe of Refrigerants (unit) Φ6 Φ9 Method of Connection Flared Joint Flared Joint Elevator ir Conditioner Elevator air conditioner is specially designed for temperature control of elevators in hotel, office building and residential building. The unit is with beautiful appearance, compact structure, complete functions and reliable performance, which can satisfy different customers' requirements. Inner groove copper ashable filter Intelligent control according to the operation status of elevator. Compact structure. Innovative malfunction feedback function. Fresh air supply. Clock timer function. ~3 Quality motor High efficiency Dualside noisesilencing hose to decrease noise efficiently. Energy saving function Outer signal wire adopts MP terminal connection, convenient and reliable. operation temperature range(db) ~43 YBF Fresh air supply ventilation ow voltage startup ide voltage startup Notes:.This unit is designed, manufactured and inspected according to National Standard GB/T Tested ambient temperature of cooling capacity: indoor side dry bulb temp. 4, web bulb temp.7outdoor side dry bulb temp.. 3. Noise was measured according to relavant standard of halfanechoic room, so in actual operation, noise may increase as ambient temperature changes. 4. Specific parameters shall be referred to unit nameplate and subject to change without prior notice. 5.mbient temperature range for operation:48 6. ll the above models can realize modular operation. 7. ny other special requirements, please contact us.. GDT5 GDT 3 BTU/h /COP Input current // // Sound pressure level ir flow volume (H/M/) db () 3 m /h ( D H) Package Fan motor supply air outlet diameter Condenser pipe diameter oading quantity 4'GP/4'HQ inch() inch() 46/5 7.44(84).76(7) 76/345 59/ (84).76(7) 8/8 Note: Elevator C is not fit for selling to the regions under the requirement of any certifications or energy efficiency. Gree reserves the right to modify the specifications without prior notice. Please confirm the final specifications with sales representatives. 39/4

36 REFERENCE PROJECTS Reference Projects Reference Projects ineup Country Project Name Installed Series Philippine Tosot Philippines Corporation GMV5 PV Iran Tehran University PV Inverter Centrifugal Chiller Macedonia Nikob Cash Center Skopje GMV5 PV Thailand 7 Store GMV5 PV Italy Expo 5 GMV4; GMV5 Brazil 6 Rio de Janeiro Olympics Games GMV4; GMV4 Mini; Free Match; Splits Bulgaria G. sparuhov Stadium GMV 4; Caste IDU Russia Mordovia rena atercooled Screw Chiller; Fan Coils Malawi National Stadium GMV5 Duct System Mordovia rena atercooled Screw Chiller; Fan Coils Russia Sochi MoreMall Centrifugal Chiller Russia South frica ngola Russia India Soccer CitySoccer Stadium of FIF FNB StadiumMain Stadium of frica Cup of Nations Sochi MoreMall Bicon Headquarter Building atercooled Packaged Unit Digital D4 (Modular Digital VRF); Duct Split Unit Centrifugal Chiller atercooled Screw Chiller; ircooled Screw Chiller France Trattoria Restaurant UMatch; Duct UK ymondham eisure Centre GMV5 Heat Recovery UK Sketch GMV5; Umatch Split Systems Russia Mir Kino Cinema Duct Myanmar Grand Hantha International Hospital Inverter Centrifugal Chiller; HU; Fan Coil Sudan Ministry of Finance GMV5 Cuba CECMED National Pharmacy aboratory atercooled Screw Chiller; Hydronic ir Handling Unit; Fan Coil Unit Malta ST James Hospital ircooled Scroll Chiller (C Series); Mini Chiller Bulgaria Sliven Town ibrary ircooled Scroll Chiller Senegal Grande Mosquee De Touba atercooled Package Unit Brazil Farroupilha Porto legre School GMV4 Mir Kino Cinema Duct Russia Expo 5 GMV4; GMV5 Italy UK Russia Sudan Serbia Richmond upon Thames College Uralzheldorproekt Institute National University Sudan Student Dormitory in Novi Sad GMV5 GMV GMV4 DC Inverter Modular ircooled Screw Chiller Panama Panama De Universidad Technology DC Inverter GMV Bahrain IBN School Rooftop Package Unit Cyprus ancashire University DC Inverter GMV UK Persion Homes HQ GMV5 Heat Recovery Russia VMOrto Business Center GMV Indonesia Oppo and J &T Office Towerandmark Pulit GMV5 Duct System; GMV5 Fresh ir System; C Elevator; ir Curtain Indonesia Satoria Tower GMV5; GMV5 Duct ; Split all Mounted Oman l Habsi GMV5 Oman Raha Towers GMV5 Compact Bahrain Millennium Tower Fan Coil Unit Oman Trading Building ir Cooled Screw Chiller ymondham eisure Centre GMV5 Heat Recovery UK Buha Versati Serbia Costarica Russia Croatia ebanon Ins Call Center Green Park Coercial Center FIN Rijeka CUBIC Coercial Center DC Inverter GMV DC Inverter GMV ircooled Scroll Chiller (C Series) GMV5 Palestine Ministry of Foreign ffairs DC Inverter GMV Pakistan l Tijara Building DC Inverter GMV Serbia Buha Versati Indonesia Sudirman Suites Centrifugal Chiller; Concealed Ceiling ; HU; Duct ; all Mounted Unit Sri anka storia GMV5; Duct Myanmar Golden City GMV5; Duct ustralia Subi Strand GMV5 Mini ustralia Toccata GMV5 Mini ustralia inq GMV5 Mini ustralia Unison GMV5 Oman ER Real Estate GMV5 Sketch GMV5; Umatch Split Systems UK Trattoria Restaurant UMatch; Duct France Iraq NawRoz City5 uxury partment Super Free Match 4/4

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

Air-to-water Heat Pump Monobloc Versati

Air-to-water Heat Pump Monobloc Versati Change for life Air-to-water Heat Pump Monobloc Versati Engineering Data GREE ELECTRIC APPLIANCES, INC.OF ZHUHAI CONTENTS 1 Product Data... 1 1.1 Lineup... 1 1.2 Nomenclature... 1 1.3 Product Features...

More information

Hot Water Heating Systems

Hot Water Heating Systems Hot Water Heating Systems Find out more at www.greeonline.com Key Wide Range of Operation Conditions Heating -26 C 46 C Features The Ultra Hot Water system is specifically designed to be flexible in its

More information

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

HEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd.

HEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd. Gre en Partner of 00 Shanghai Expo Sole Designated Heat pump supplier for ZED PVILIONPartner of 00 Shanghai Expo Sole Designated Heat pump supplier for ZED PVILION Dongguan New Times New Energy Science

More information

Mini unitary chiller. Mini unitary chiller

Mini unitary chiller. Mini unitary chiller Mini unitary chiller Mini unitary chiller Product description Features and benefits Description of main components Specification Operation limits Hydraulic performance Dimension Service space Piping diagram

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity: 0RB/RQ ircooled Liquid Chiller Reversible irtowater Heat Pump 0RB: Nominal cooling capacity: 159758 0RQ: Nominal cooling capacity: 160 Nominal heating capacity: 1895 Features The quasnap Puron liquid chillers/airtowater

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

HERO SERIES-DC INVERTER HEAT PUMPS

HERO SERIES-DC INVERTER HEAT PUMPS HERO SERIES-DC INVERTER HEAT PUMPS PHNIX DC inverter heat pump can work efficiently with floor heating, water fan coils or radiators for heatingcooling. WATER FAN COILS DC INVERTER HEAT PUMP FLOOR HEATING

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER AIR CONDITIONER manufactured with latest inverter Technology 97% of operating power from solar energy very low Power consumption levels Eco-friendly, reduced

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA... FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN

More information

DESIGN ITALIANO

DESIGN ITALIANO DESIGN ITALIANO 01-06-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative

More information

ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER

ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER (GC201503- ) TTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDI TECHNICAL SALES GUIDE-50Hz

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data VANJSKE JEDINICE Variable Refrigerant Flow Systems *Preliminary data Index Key Features 0 Outdoor Units 5 Indoor Units 86 Control Systems Central Control Software 8 Accessories Heat Recovery Ventilator

More information

50A KP 70A KP 90A KP 120A KP 150A KP 210A

50A KP 70A KP 90A KP 120A KP 150A KP 210A DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw

More information

OIL FREE CENTRIFUGAL CHILLER

OIL FREE CENTRIFUGAL CHILLER OIL FREE CENTRIFUGL CHILLER OIL FREE CENTRIFUGL CHILLER High Efficiency Energy saving and high efficiency The unit adopts the turbo inverter compressor technology and frictionless technology, which will

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP 1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling,

More information

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded

More information

All DC Inverter Multi VRF

All DC Inverter Multi VRF All DC Inverter Multi VRF In 2012, Gree highly promoted GMV5 All DC Inverter Multi VRF New breakthrough in comfort ability, intelligent control and design. Eight prominent advantages More powerful product

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

Flexible. The. Chillers

Flexible. The. Chillers MFCA FreeControl Variable Frequency Modular Heat Pump Energy Saving & High Efficiency Flexible & Reliable Environment Friendly The Creatorr and Leader of Modular Chillers Contents What is MFCA Features

More information

AIR TO WATER HEAT PUMP SERVICE MANUAL Versati II

AIR TO WATER HEAT PUMP SERVICE MANUAL Versati II AIR TO WATER HEAT PUMP SERVICE MANUAL Versati II T1/R410A/50Hz (GC201308- ) CONTENTS PRODUCT... 2 1 MODELS LIST... 2 1.1 Main Unit...2 1.2 Water Tank...2 2 NOMENCLATURE... 2 2.1 Main Unit...2 2.2 Water

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units Coercial Air Conditioners 07/08 INVERTER DC Inverter Aqua Mini Chillers & Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

Air-cooled modular Chiller. Nick Technical Engineer

Air-cooled modular Chiller. Nick Technical Engineer Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

SUPER FREE MATCH. Smart Zone Controller. It can directly control 16 indoor units in the network without extra communication module.

SUPER FREE MATCH. Smart Zone Controller. It can directly control 16 indoor units in the network without extra communication module. Smart Zone Controller It can directly control 16 indoor units in the network without extra counication module. Max. 16 Indoor Units Smart Zone Controller Note: Can t use on wall mounted type indoor unit.

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

DC inverter VRF presentation

DC inverter VRF presentation DC inverter VRF presentation NINGBO DEKON REFRIGERATION EQUIPMENT CO., LTD Wangchun Industrial Park, Yinzhou district,ningbo, China. Tel: 0086-574-88152763 Mob: 0086-15356475680 www.dekon-hvac.com Email:

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

DAIKIN Huizhou Factory Profile

DAIKIN Huizhou Factory Profile DAIKIN Huizhou Factory Profile DAIKIN AIR-CONDITIONING (SHANGHAI)CO.,LTD HUIZHOU FACTORY The manufacture base of central air-conditioner in China Established Daikin group, a wholly owned subsidiary Amalgamated

More information

DES IGN I T ALI A N O

DES IGN I T ALI A N O DES IGN I T ALI A N O 01-04-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning : Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113 tu 137 IR COOLED Liquid chiller equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel CONDENSING coils 280 1500 kw Energy Class More efficient

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by: Johnson Controls - Hitachi Air Conditioning Manufactured by: Johnson Controls-Hitachi Wanbao Air Conditioning (Guangzhou) Co.,Ltd. Address:No.110.ChengAo East Road, Conghua,Guangzhou City, Guangdong Province,China

More information

Air Cooled Scroll Chiller / Heat Pump

Air Cooled Scroll Chiller / Heat Pump Air Cooled Scroll Chiller / Heat Pump SRA 145 Nominal Capacity 67.5 to 1080 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data R407c 5 Physical Data R134a 6 Unit Performance

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

DC inverter Outdoor-air Processing unit (GC )

DC inverter Outdoor-air Processing unit (GC ) DC inverter Outdoor-air Processing unit (GC201109- ) ER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTERNDITINER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:14~56kW

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

2017 LINE UP MINI SPLITS CATALOG

2017 LINE UP MINI SPLITS CATALOG SINGLE ZONE MULTI ZONE LIGHT COMMERCIAL 2017 LINE UP MINI SPLITS CATALOG Residential & Light Commercial Solutions WELCOME SERVICE & SUPPORT We believe that the best way to ensure the complete satisfaction

More information

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series Rev. 3.32 26.01.2007 CONTENTS 1. Preface 3 2. Specifications 4 2.1 Performance Data of swimming Pool Heat Pump Unit 4 2.2

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

K sin. Mini Split Air Conditioners and Heat Pump

K sin. Mini Split Air Conditioners and Heat Pump Mini Split Air Conditioners and Heat Pump K sin Environment concern is a priority all over the world. Environment concern is our responsibility and working philosophy. 140 105 70 35 Noise Level db(a) Level

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components.

More information

HEAT PUMP & HEAT PUMP & SOLAR HYBRID SOLAR HYBRID AIR CONDITIONER AIR CONDITIONER

HEAT PUMP & HEAT PUMP & SOLAR HYBRID SOLAR HYBRID AIR CONDITIONER AIR CONDITIONER HEAT PUMP & HEAT PUMP & SOLAR HYBRD SOLAR HYBRD AR CONDTONER AR CONDTONER Jiangsu Sunchi New Energy Co.,Ltd Add:Zhangnian ndustrial Park,Huangtang Town, Danyang City,Jiangsu Province,China Tel:+86 511

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

RIGID DC LIQUID CHILLER

RIGID DC LIQUID CHILLER RIGID DC LIQUID CHILLER Phone: +86-579-8837-9768 Email:info@rigidhvac.com Website: www.rigidchill.com 1 1. WHAT S LIQUID CHILLER? Liquid Chiller cooling refers to cooling by means of the convection or

More information

AHU Plus. DX Air Handling Units

AHU Plus. DX Air Handling Units AHU Plus DX Air Handling Units AHU Plus DX DX Air Handling Units AHUPlusDX-TH: DX Air Hadling Unit with 100% Fresh Air AHUPlusDX -IGK: DX Air Hadling Unit with 100% Fresh Air and Heat Recovery AHUPlusDX-KH:

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information