1 A Product of Advanced Radiant Systems, Inc. CSW-12-VD Portable Evaporative Cooler IMPORTANT SAFETY INFORMATION INSIDE MADE IN Serious injury or death possible Read, understand, and follow all safety information and instructions in this manual before using or servicing this product. USA Retain these instructions for future reference. Page 1 of 16

2

3 INDEX Index Page 2 Signal Word Definitions Page 2 General Description and Use Page 3 Specifications Page 4 Wiring Page 4 How Evaporative Cooling Works Pages 5 & 6 Unpacking Page 6 & 7 Assembly Instructions Pages 7 Connecting the Water Supply Page 8 Connecting the Electrical Supply Page 8 Start-Up Procedure Page 9 Maintenance Pages 10 & 11 Troubleshooting Page 12 Replacement Parts Page 13 Warranty Page 14 ATTENTION: The table to the right provides definitions of the signal words that can be found throughout this manual. These signal words are used to express the severity of the hazard at hand. The signal words are generally used in conjunction with safety symbols that correspond to the text for that particular hazard. As you read this manual, refer back to this table when you are unsure of the signal word definition. Page 2 of 16

4 GENERAL DESCRIPTION & USE ELECTRICAL SHOCK HAZARD FIRE HAZARD Serious injury or death may occur. Do not use in locations containing hazardous or explosive atmospheres. Do not use outdoors in wet conditions and in unprotected locations. This unit is a compact, self-contained, highefficiency portable evaporative cooler capable of lowering existing temperatures by as much as 26 degrees. The unit draws air across watersaturated high-efficiency cooling pads, causing a gradual evaporation of the water, thereby removing heat from the air. The 10-gallon reservoir provides hours of operation without a water supply. Evaporative cooling is also environmentally friendly, since it does not use chlorofluorocarbons (CFC s), and therefore does not contribute to ozone depletion. Features Reduces air temperatures up to 26- degrees Cools an area of approximately 900 sq. ft. (30 x 30 ) 4 thick highly efficient cooling pads Four 3 diameter swivel bearing wheels, two locking, for easier portability and positioning over many surface types. Indented top for tool & product placement Internal reservoir with water capacity of 10 -gallons for remote applications, includes oversize inlet opening for reservoir filling. Auto fill hose connector for continuous use with a garden hose Includes 17 long cord with ground fault 120 volt plug Benefits Significantly reduces air temperatures and generates a cooler and more comfortable working environment Compact portable cooling system with quiet fan axial blower design Easy to operate and maintain, plus an economical solution for low cost spot cooling Cooling media pad contains a paper treated CELdek material with a rigid protective edge coating (Munters MI-Tedg ) to extend the life of the pad, plus provide added weather and algae protection, durability, and formulated to withstand repeated cleaning without damage to the pad Ready to plug into any 120VAC receptacle and hooks up to any standard garden hose for direct water supply Applications would include workshop environments, material handling areas, automotive shops, office areas, and many more! Page 3 of 16

5 SPECIFICATIONS Air Volume Fan Motor Cooling Media Type Cooling Media Size Water Reservoir Capacity Switch Cord Protective Guard Power Supply Unit Dimensions Unit Weight Water Supply 3800-CFM (2200-CFM Low), 6FT Variable CELdek high cellulose paper treated media pads for effective cooling and resistance to edge degradation. Cross-fluted design induces highly turbulent mixing of air & water for optimum cooling and enhanced self-cleaning. 18" x 18" and 4" thick 10 - gallons Variable 17 long, 18 ga. 3-conductor cord GFCI CSW-12VD Oscillating 120-VAC; 60 Hz; 3-Amps 21-1/4" wide x 27-1/2" tall x 23 deep 51 lbs. (without water in reservior) Standard garden hose connection or hand fill reservoir WIRING Page 4 of 16

6 HOW EVAPORATIVE COOLING WORKS To understand how the portable evaporative cooler works a basic understanding of psychrometrics is necessary. Psychrometrics is the branch of thermodynamics devoted to the study of air and water vapor mixtures. The psychrometric chart is a graphical representation of properties of moist air. To illustrate how the unit operates, some of the relevant properties are described in this section followed by a sample application. Dry-bulb temperature is measured with a thermometer. Dry-bulb temperature lines on the psychrometric chart are the vertical lines. The wet bulb temperature is the lowest temperature that can be reached by evaporating water into the air. DRY BULB TEMP WET BULB TEMP DEW POINT TEMP Dew-point temperature is the temperature to which a given sample of air must be cooled so that moisture will start condensing out of it. When air is saturated, the dry-bulb, wet-bulb, and dew-point temperatures will all be equal. The horizontal lines show the dewpoint temperature on the psychrometric chart. Relative humidity is the amount of moisture in the air relative to the amount of moisture the air would hold if saturated at that dry-bulb temperature. Percent humidity is not the same as relative humidity and is not used in HVAC design. This graph shows the relative humidity curves on the psychrometric chart. Page 5 of 16

7 The following example illustrates the use of the psychrometric chart as it relates to evaporative cooling. Since all of the items described above are properties, any two of them describe a state point on the psychrometric chart. Once this point is determined, the values of all the other properties can be read from the chart. The example below shows a Mollier type psychrometric chart for atmospheric pressure. The dot shown is a state point and the following properties are known about the air/water mixture at this state. Dry-bulb temperature: 97 Wet-bulb temperature: 78 Dew-point temperature: 71 Relative humidity: 43% 78 F 71 F 43% WET BULB TEMP DRY BULB TEMP 97 F Take the air/water mixture described by the state point above, with a dry-bulb temperature of 97 and 43% relative humidity, for example. As the air passes through the cooling media on the unit, moisture is added to the air increasing the relative humidity. This increase in relative humidity brings a decrease in dry bulb temperature. When the relative humidity is raised to 70%, the dry bulb temperature has dropped to 86 F. When the humidity level approaches 100%, the dry bulb temperature has dropped nearly 20 F to 78 F. UNPACKING Inspect your unit for any concealed shipping damage and report it immediately to your carrier. In addition to our evaporative cooler the following items are included in a hardware pack and will need to be installed before operating the unit. Non-Swivel w/ lock (qty. 2) Swivel Casters: (qty. 2) Page 6 of 16

8 Screws: (qty. 8) Pads ASSEMBLY ELECTRICAL SHOCK HAZARD Serious injury or death may occur. Disconnect from electrical supply before and during assembly of this product. Wheel Assembly Tools required: 7/16 nut driver 1.) Turn unit over and place on cardboard to protect finish 2.) Align wheel plate with embedded nuts on bottom of housing 3.) Attach using (2) screws 4.) Repeat steps 2 and 3 for each wheel Pad Installation 1.) Remove pad retainer bar 2.) See page 12 Washer (2) Screws (2) Bottom of unit Casters (4) Screws (2) Pad retainer bar Page 7 of 16

9 CONNECTING THE WATER SUPPLY ELECTRICAL SHOCK HAZARD Serious injury or death may occur. Disconnect from electrical supply before and during assembly of this product. -Do not connect this unit to any water source where the water pressure exceeds 60 psi. This will cause permanent damage to the unit. Pressures above 60 psi must use a pressure regulator. A pressure reducing valve is installed on the float inlet. -Do not fill the reservoir past the MAX water level line indicator. Garden hose connection: This unit comes equipped with pressure regulator a female garden hose adapter that can be connected to any standard garden hose. The float will automatically maintain the correct water level. DO NOT over tighten as this may cause the float assembly to rotate resulting in over filling of reservoir. Stand-alone: This unit can also be manually filled and moved into position. To fill the unit; simply remove the fill cap located on the side of the housing, fill with water, and replace the cap. NOTE: Do not fill the reservoir past the max water line. Water can easily spill from inside the unit when rolling the cooler on uneven surfaces or if the reservoir is overfilled. CONNECTING THE ELECTRICAL SUPPLY ELECTRICAL SHOCK HAZARD Serious injury or death may occur. Make certain the power source conforms to specifications on data label. Do not connect plug to power supply without cooling pads installed and fastened in place. This cooler comes equipped with a 120-volt power supply cord and should only be plugged into a 120 VAC, 60 Hz branch circuit that includes a properly sized over current protection device (fuse or circuit breaker). Consult a licensed electrician if there is a question about adequacy of the electrical supply. EXTENSION CORDS Use only 3-conductor extension cords of 14AWG to 25 ft., 12AWG to 50 ft. & 10AWG to 100ft. length maximum. Do not use the extension cord powering this cooler to power any other appliances or electrical loads. Page 8 of 16

10 START-UP PROCEDURE Do not operate the pump when the reservoir is dry. This will cause the pump to fail and also void the warranty. There are 4 factors to consider when determining where to place your evaporative cooler. 1. Fresh air supply: The inlet side of the unit (pad side) requires a constant, uninterrupted supply of fresh air for maximum performance. A distance of 3 ft. of clear space is recommended. 2. Discharge airflow: The cool air discharged from the unit should be free of obstruction to allow the air to circulate in order to maximize the cooling zone. 3. Ventilation: Allow cooled air to circulate away from discharge area of cooler. This ensures that the unit does not re-circulate air that has already been through the evaporative cooling process. 4. Placement: The unit must be placed on a level surface to operate correctly. The units create an oval shaped air pattern that can reach out as far as 20 feet. Obstacles such as racks and workbenches may interfere with the cooling zone. An attempt should be made to locate the unit in such a manner that interruption of the air pattern is held to a minimum. Multiple units may be required to cover large areas. Initial start-up: Clean out the Sump: Remove any foreign material in the sump before start up. It is normal for some debris to accumulate in the sump. It is best to flush out the sump with water to clear any debris. Filling the unit with water: Once the unit has been hooked up to a water source, turn the water supply valve on and the unit will fill with water. The float valve will shut off the water flow when the reservoir is filled. ELECTRICAL SHOCK HAZARD Serious injury or death may occur. Disconnect from electrical supply before servicing this product. Starting the pump: Allow the reservoir to fill before turning the pump on. Once the reservoir is full, the pump switch may be turned to the ON position. Initial Washing of the Cooling Media: The media should be washed for several hours by running the pump without any airflow through the media. This washing action will clean out any debris in the media as well as reduce any odor and improve wetting ability. Break in Period for Cooling Media: The media will reach its peak operating condition after about 100 hours of operation. The chemical constituency rigidifying agents in the media will then be set and will not leach out further. Ignore any coloration in the water during this initial period. If a strong odor persists, run the pump to flush the media with water, without airflow through the media, until the odor disappears. Annual start-up: At the beginning of each cooling season follow the same procedures as the initial start-up with some possible exceptions. If the media was removed for the winter, it will have to be replaced (note instructions below on media replacement). Check the condition of the media. If the flutes of the media are clogged with buildup of alkali deposits or are otherwise damaged, consider replacing the media. This is the best time to make this decision while the unit is not being used and may not be as critically needed. Page 9 of 16

11 ODOR CONTROL One of the few inconvenient aspects of evaporative cooling is the control of unpleasant odors. There are two primary causes of these odors: 1. Initial wetting of new pads 2. Poor maintenance and storage behaviors and/or poor quality water. Your EVAP-series cooler has been delivered with pads that have never been wet. The same is true of replacement pads. The resins and adhesives used to create these pads will give off an odor during initial use that can last for a week or more. This can t be avoided but it can be minimized. As the cooler is used over time, algae and bacteria growth can occur. This can also be minimized. Below are recommended actions to be taken to address noticeable odor due to the above causes. Odor from Initial Wetting of Pads 1. At first use of your new cooler or after installing new replacement pads, make certain there is lots of fresh air available to the cooler. 2. Add one capful of liquid laundry fabric softener to the water in the bottom reservoir of the cooler. 3. The odor from initial wetting of pads should disappear in approx. two weeks of operation. 4. If odor does not disappear after two weeks of operation, follow the steps for Periodic Odor Maintenance. Periodic Odor Maintenance 1. Make certain the cooler is full of fresh water. 2. Flush the pads for 3 4 hours by operating the pump only with the fan off. Adjust flow control valve for maximum rate of recirculating water flow. 3. After flushing, empty the reservoir through the front drain and clean out any residual particulate in the reservoir. 4. Refill reservoir with fresh water and proceed to use the cooler. 5. Repeat the above steps as necessary to eliminate odor. Page 10 of 16

12 MAINTENANCE Water Chemistry CHEMICAL BURN HAZARD POISONOUS GAS HAZARD Serious injury or death may occur. Read, understand and follow all chemical manufacturers instructions when using the chemicals noted in these pages. Algae/Bacterial Control Control with chemicals. Chlorine is the most commonly used chemical to control organisms. It is potentially dangerous and should be used with great caution. One of the best methods to introduce chlorine into the water circulation system is on the pressure side of the pump on a continual or timed basis. Note: Consult water treatment experts before attempting chemical water treatment. Neither media manufacturers nor equipment manufacturers warranties cover damage due to chemical water treatment and warranty may be voided when chemicals are used. Other chemicals suitable for organism control include hydrogen peroxide, bromine based oxidizers, and other commercial products. It is important to maintain a 6 to 9 ph level after treatment. Control without chemicals. With water, sunlight, and nutrients, most organisms can survive. The water in the media can be allowed to dry out and any organisms living in the media will become dry and flaky. This can then be flushed out at the next start up of the unit. Shading the media will prevent the sunlight from encouraging the growth of organisms. Nutrients are available from the air itself, however in some instances, phosphates and fertilizers are carried in the air stream and should be avoided. Flushing the media with fresh water and dumping the sump water periodically is the best preventative measure that can be taken. This flush and dump action will actually prevent alkali deposits and algae/bacteria from growing. There are also some non-recirculating water distribution systems available that provide a constant flushing/dumping action. Hard water contains relatively large amounts of minerals, primarily calcium. A sample of water can contain only a specific maximum amount of dissolved solids in solution. If these concentrations increase beyond a certain level, the excess minerals precipitate out as a solid material. This precipitation will appear as the familiar white residue left on the face of the media. It is commonly referred to as alkali, calcium depositions or salts. The same process occurs in the desert when water collects in depressions and since only pure water evaporates the minerals are left behind. These are commonly referred to as dry lakes or salt flats. The build up of these minerals on the face of the media does not because a problem until the airflow is restricted. There is no easy way to remove these deposits. The best solution to this problem is preventive rather than corrective action and usually requires simple actions such as media flushing with fresh water and periodic dumping of the sump water. Soft water is on the opposite side of the scale for water chemistry as compared to hard water. Basically, removing or diluting the effects of the calcium in the water creates soft water. Soft water is not to be confused with pure water. Pure water does not contain or contains very small amounts of minerals found in either hard or soft water. While hard water can leave deposits in the media, soft water can cause harm to the media by leaching out the rigidifying agents. Either water condition can have some adverse effects on the media. PH Range. A ph range of 6 to 9 is the acceptable range for the media, the closer to the center the better. The re-circulating system of the water distribution allows the mineral content in the sump water to become more and more intensive because the same water is re-circulating. The pure water is lost to evaporation while the minerals just continue to build up. TDS is the abbreviation for Total Dissolved Solids and represents, as the name implies, a way of identifying a measurement of the mineral content. Page 11 of 16

13 Removing the cooling media: ELECTRICAL SHOCK HAZARD Serious injury or death may occur. Disconnect from electrical supply before servicing this product. To keep your unit operating at peak efficiency, ensure that the cooling pads are kept clean and dust-free. Dust and other particles have an adverse effect on the media s ability to introduce water into the air stream. If the pad surface becomes dirty or dusty, clean with a soft brush and water. Daily maintenance: At start-up: It is best to run the pump several minutes before the fan is started to clean out any debris on the media. In order to perform any maintenance on internal components the cooling pads must be removed to access the inside of the unit. Media removal / replacement is simple, if you follow these instructions! The media is soft when wet so be very careful when handling. The media has two separate flute angles, which are transverse to each other and alternate across the face of the media. One flute is 45 and the other is 15. The alignment of the flute arrangement in relation to the direction of airflow is critically important. The 45 flute must be aligned upwards in the direction of the airflow. The 15 flute must be aligned downwards in the direction of the airflow. 1. Using a 5/16 nut driver, remove the (2) screws holding the pad retainer bracket in place. Save all hardware. 2. The pad may be tilted out of the unit and lifted out of the drain tray. Note: Reinstall pads correctly; refer to sides of pad material for airflow direction. At shut-down: When shutting down your evaporative cooler at the end of each workday, the pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the pads to drain and dry out. This simple guideline will ensure long and efficient pad life as well as help to control mildew and bacteria growth. Periodic maintenance: Depending on how often the unit operates, this procedure should be performed anywhere from every week for heavy use to monthly for light use. Screws 1. Drain reservoir. 2. Remove cooling pads. 3. Clean out reservoir with either a towel or wet/dry vacuum. 4. Reinstall pads and pad retainers. Pad retainer Pad material Airflow Direction Annual shutdown / Storage: 1. Wash down the media to flush out all the debris. 2. Open the drain in the sump to drain out any standing water. 3. Wash the interior of the unit to remove any algae or micro-organisms as well as calcium deposits. A weak dilution of muriatic acid will help clean the alkali (calcium) deposits. Commercial chlorine will kill and clean out the algae. 4. Store the unit in a dry area and cover if possible to prevent dust build-up. CHEMICAL BURN HAZARD POISONOUS GAS HAZARD Serious injury or death may occur. Read, understand and follow all chemical manufacturers instructions when using the chemicals noted in these pages. Page 12 of 16

14 TROUBLESHOOTING ELECTRICAL SHOCK HAZARD Serious injury or death may occur. Disconnect from electrical supply before servicing this product. Fan System: The fan system consists of two primary elements: Fan Blade and Motor Problem Check Solution Fan won t run and makes no sound. Power cord, extension cord, switches, and circuit breaker. Reconnect power or extension cord. Reset breaker. Fan motor won t run and makes a Motor stalled (will not turn by hand). Replace motor. humming sound. Breaker trips or fuse blows when fan is started. Motor stall. Check power source for min. 115v/10 amp. Replace motor. Upgrade power supply. Motor overheating and shutting off. Restarting several minutes later. Fan motor won t run and switch makes soft clicking sound. Extension cord adequacy. Extension cord gauge too small. Inlet air obstructed or too close to wall. Faulty motor. Switch making good contact. Replace with heavier cord. Replace with heavier cord. Provide additional inlet clearance. Replace motor. Replace switch. Water Systems: The water delivery system consists of four primary elements: Water Hose, Float Assembly, Pump, and Water Distribution Channel. Problem Check Solution Floor at side of the unit is wet. Water inlet hose is loose at supply hose. Tighten connections and/or replace hose washers. The unit overflows from reservoir. Float valve hose is loose at bulkhead fitting or at float valve. Water pressure is too high to allow float valve to shutoff (60psi max). Float valve is not seating properly. Tighten connections and/or replace hose washers. Reduce water pressure by adding an inline pressure reducer. Check float valve. Replace float Water leaking from drain valve. Make sure drain nut is secure. Tighten drain nut. Too many dry streaks in the pads. Holes in water distribution tray are Remove distribution tray and clean blocked. Water spitting from the unit. Hose connection loose. Tighten hose. Pump motor will not run when switch is turned on. Check switch, cord and circuit breakers. Replace hose and washer. Replace switch and reset breaker. Page 13 of 16

15 COMMON REPLACEMENT PARTS ITEM DESCRIPTION PART NO. QUANTITY NO. 1 FAN ASSEMBLY CS-F12-VD 60HZ 1 2 ON/OFF SWITCH CS-E VARIABLE SWITCH CS-E187-VD 60HZ 1 4 PUMP CS-E FLOAT CS-P PAD MEDIA KIT CS-A WARRANTY WARRANTY Your COOLSPACE unit is guaranteed against any defective material or workmanship for a period of 12 months from your date of original purchase. Please call (800) to receive a returned goods authorization number to return and receive any defective parts. Shipping costs for returns are at the expense of the customer. It is our goal to have satisfied Customers, and to provide you with any support you may need. If you have any questions about our product, operation or are having technical problems please call IN CASE OF PRODUCT FAILURE: Please have the following information ready when you call: 1. Model Number and Serial Number. 2. Proof of purchase. 3. Description of the problem encountered with product. SELLER'S LIABILITY Seller will not be liable for any loss, damage, cost of repair, incidental or consequential damages of any kind, whether based on warranty, contract or negligence, and arising in connection with the sale, use or repair of the Products. Seller's maximum liability shall not in any case exceed the contract price for the Products claimed to be defective or unsuitable. RETURNED GOODS Equipment may be accepted for return with in 90 days of shipment, when authorized by us with our return labels. Request necessary permission and special Return Authorization Tags. Currently listed equipment in new and unused condition, and in factory sealed cartons, may normally be returned for full credit less 25% (minimum charge $20.00) charge for handling, repacking and restocking, and less transportation charges both ways, at net prices prevailing at time of purchase or time of return, whichever is lower. Advanced Radiant Systems, Inc., however, reserves the right to refuse any return, at our discretion, and is not responsible for error. All special, custom made or equipment with special finishes, and modified versions of cataloged numbers are not returnable. All returned merchandise is subject to inspection. Unsalvageable and damaged merchandise will be credited at salvage value or less costs of repairs. DAMAGED GOODS Minimum charge on replacement will be waived if order is accompanied by copy of proof of claim submitted to carrier. No repair, replacement, or other adjustment by the customer is authorized by us, unless so stated in writing by our Sales Service department. DO NOT DISCARD FAULTY PARTS! THEY MUST BE RETURNED IN ORDER TO RECEIVE WARRANTY CREDIT Page 14 of 16

16

17 COOLSPACE Warranty Form Date Purchased: Purchased From: Model Number: CSW- Serial Number: Company: Contact: Address: Phone Number: Fax Number: You must complete this form and return within fifteen (15) days of initial purchase to validate your cooler s warranty. Please call COOLSPACE (800) if you have questions. Please fax or mail this completed form to: Fax to: (317) Mail to: COOL-SPACE Warranty Dept. 315 N. Madison St. Fortville IN Submit online: under the CONTACT tab. Page 15 of 16

18

19 IMPORTANT NOTICE: DO NOT RETURN TO PLACE OF PURCHASE. Please call for technical service support and warranty information If you have questions about the product you have purchased or would like to leave us feedback, please contact us via our website or by calling North Madison Street, Fortville IN Phone: Fax: REV 06/14jw PN CSW-VD MANUAL Page 16 of 16

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up

More information

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ CS6-50-VD Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up of COOL-SPACE

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Contents 1.0 INTRODUCTION... 1 2.0 UNPACKING YOUR COOL-SPACE UNIT... 1 3.0 SET-UP

More information

Operation & Maintenance Manual for

Operation & Maintenance Manual for Operation & Maintenance Manual for CS5-16, CS5-36 & CS5-48 Series 12910 Ford Drive Fishers, IN 46038 Phone: 317-577-0417 Fax: 317-842-3989 1-800-557-5716 www.cool-space.com sales@cool-space.com Operation

More information

Operation & Maintenance Manual for

Operation & Maintenance Manual for Operation & Maintenance Manual for CS5-16, CS6-36 & CS5-48 Series 1-800-557-5716 www.cool-space.com sales@cool-space.com www.cool-space.com sales@cool-space.com 1(800)557-5716 Due to continuous product

More information

SELF-CONTAINED POWER MISTER

SELF-CONTAINED POWER MISTER 00 North Main St. Fostoria, OH 0 Phone: 00-95-55 Fax: 9-5-0 www.tpicorp.com If you have questions about the product you have purchased or would like to leave us feedback please contact us via our website

More information

48 MaxxAir Portable Evaporative Cooler Owner s Manual

48 MaxxAir Portable Evaporative Cooler Owner s Manual 48 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers all of the following MaxxAir Portable Evaporative Coolers. EC48D1 MaxxAir 48 Belt Drive 2 Speed File this owner s manual in a safe

More information

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler. 18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler. File this owner s manual in a safe place for future reference. It contains operating

More information

Manual update 2016 MC37/MFC3600

Manual update 2016 MC37/MFC3600 Manual update 2016 MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You

More information

Manual for MC37/MFC3600

Manual for MC37/MFC3600 Manual for MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel

More information

Manual for MC21A SETUP INSTRUCTIONS

Manual for MC21A SETUP INSTRUCTIONS Manual for MC21A SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

Manual for MC91 SETUP INSTRUCTIONS

Manual for MC91 SETUP INSTRUCTIONS Manual for MC91 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

Portable Evaporative Cooling System

Portable Evaporative Cooling System Portable Evaporative Cooling System User s Manual Manufactured by HH Technologies, Inc. 1733 County Road 68 Bremen, Alabama 35033 256-287-7000 Part No 4801-5035 Rev 03-2017 User s Manual PolarCool Table

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

If you have any problems with this product, please call BEFORE returning it to your retailer.

If you have any problems with this product, please call BEFORE returning it to your retailer. CP35 PORTABLE EVAPORATIVE COOLER USE & CARE GUIDE Read and Save These Instructions If you have any problems with this product, please call 1-800-643-8341 BEFORE returning it to your retailer. NOTICE: This

More information

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX INDEX Safety Rules... 1 Quick Start.... 2 Features...3 Maintenance......4 Cooler Parts......5 Warranty......6 Trouble Shooting...7 Mobile Evaporative Cooler Use & Care Guide MC18M Safety Safety Rules 1.

More information

PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01, PACCYC02, PACCYC03, PACCYC04, PACCYC06

PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01, PACCYC02, PACCYC03, PACCYC04, PACCYC06 PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01, PACCYC02, PACCYC03, PACCYC04, PACCYC06 QUICK SETUP 1 2 3 4 Remove box and pallet Position on level surface Use with GFCI device Fill tank or attach water hose

More information

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use. 1 Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use OWNER'S MANUAL Read and save these instructions before use ON 0 3 2 OFF ON OFF COOL SPEED SWING Model: CO60PM Power rating: 220 Watts

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

Torrena 42 Ceiling Fan

Torrena 42 Ceiling Fan Torrena 42 Ceiling Fan Owner s Manual Part # 269268, 269269 Model # 32096, 32097 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China If you are experiencing

More information

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX INDEX Safety Rules... 1 Quick Start.... 2 Features...3 Maintenance......4 Cooler Parts......5 Warranty......6 Trouble Shooting...7 Mobile Evaporative Cooler Use & Care Guide MC37 / MC61 Safety Safety Rules

More information

52 CEILING FAN. Owner s Manual Models #50336, 50337

52 CEILING FAN. Owner s Manual Models #50336, 50337 52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.

More information

Camarillo 52 Ceiling Fan

Camarillo 52 Ceiling Fan Owner s Manual Camarillo 52 Ceiling Fan Part # 269263, 269259, 269287 Model # 32091, 32092, 32087 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China

More information

52 SAN LUCAS CEILING FAN

52 SAN LUCAS CEILING FAN 52 SAN LUCAS CEILING FAN Owner s Manual Models #20551 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

Portable Evaporative Cooling System

Portable Evaporative Cooling System Portable Evaporative Cooling System User s Manual Manufactured by HH Technologies, Inc. 1733 County Road 68 Bremen, Alabama 35033 256-287-7000 Part No 4801-5035 Rev 03-2017 User s Manual PolarCool Table

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

MN908 No. 282C Replaces 282B LB7013

MN908 No. 282C Replaces 282B LB7013 No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals

More information

TOUCHDOWN 48 CEILING FAN

TOUCHDOWN 48 CEILING FAN TOUCHDOWN 48 CEILING FAN MODEL #50205 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am

More information

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION DUVAL 52 CEILING FAN MODELS #50201, 50206 Español p. 19 LISTED FOR DAMP LOCATION Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883,

More information

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN Alliance Products, LLC Murfreesboro, TN 37129 1-800-522-3973 OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS Rev. 1-28 2 GENERAL INFORMATION. 3 RECEIVING INSPECTIONS.

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

30 Misting/Oscillating Fan Model Number 01030

30 Misting/Oscillating Fan Model Number 01030 30 Misting/Oscillating Fan Model Number 01030 READ AND SAVE THESE INSTRUCTIONS CAUTION: Before using this product read this manual and follow all safety rules and operating instructions. Failure to comply

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

48 TAYLOR CEILING FAN

48 TAYLOR CEILING FAN 48 TAYLOR CEILING FAN Owner s Manual Models #20554 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.- 5 p.m.

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V. HMT-D30-A HMT-D45E-A HMT-D70E-A Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A Portable Dehumidifier Operating Instructions 3119233 V.141217 General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS

More information

XC Portable Air Conditioning

XC Portable Air Conditioning PORTABLE AIR CONDITIONERS XC Portable Air Conditioning XC-14A, XC-22A, XC-30A Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents

More information

52 BERKSHIRE CEILING FAN

52 BERKSHIRE CEILING FAN 52 BERKSHIRE CEILING FAN Owner s Manual Models #20223, 20224 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9

More information

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION

More information

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE COVE DISHWASHER Contents 3 Cove Dishwasher 4 Specifications 7 Door Panel 9 Installation 15 Troubleshooting Features and specifications

More information

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS DH07 shown INSTALLATION, OPERATION & MAINTENANCE MANUAL Manual P/N 92448 Rev. G 04/02/2009 Copyright 1998 Aladdin Temp-Rite Changes may be made to the

More information

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC Use and Care Manual Flammable Material Storage Refrigerator LRBFS06W1HC 7085 471-00 Table of Contents Table of Contents Page Please Read and Follow these Instructions... 2 California Proposition 65...

More information

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon

More information

SUTTON 52 CEILING FAN

SUTTON 52 CEILING FAN SUTTON 52 CEILING FAN MODELS #50188, 50189, 50190 Español p. 19 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday,

More information

PORTABLE DEHUMIDIFIER

PORTABLE DEHUMIDIFIER PORTABLE DEHUMIDIFIER User s Manual For information or assistance, please contact: Soleus International 9451 Telstar Ave. El Monte, CA 91731 Tel: 1-888-876-5387 www.soleusair.com POWERED BY: KEEP THESE

More information

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax: A DIVISION OF FOSTORIA INDUSTRIES, INC. 1200 North Main Street Fostoria, OH 44830-1911 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com VHC-32 Variable Heat Controller for 222 MUL-T-MOUNT

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

EVAPORATIVE AIR COOLER SERVICE MANUAL

EVAPORATIVE AIR COOLER SERVICE MANUAL EVAPORATIVE AIR COOLER SERVICE MANUAL CAUTION: Before servicing the unit, read the Safety Precautions in this manual. Only for authorized service. MODEL NO.: CL30XC & CHL30XC (INDOOR USE ONLY) CONTENT

More information

SPRINGHILL 44 CEILING FAN

SPRINGHILL 44 CEILING FAN SPRINGHILL 44 CEILING FAN MODELS #50184, 50185 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday,

More information

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 CARBON SPOT 30 EXTRACTOR OPERATOR'S MANUAL IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 Diamond Products www.diamondproductsus.com Printed in the U.S.A.

More information

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE TM ANYWHERE BY U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE 2017 Minka Lighting Inc. Manual design and all elements of manual design are protected by United States Federal and/or State

More information

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is to offer

More information

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS Owners Manual For Model PACJS1600 READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Introduction... 1 How to Safely Operate your new Jetstream unit... 1 Setting up your new Port-A-Cool Jetstream 1600...

More information

S1700 Electric Pressure Washer

S1700 Electric Pressure Washer S700 Electric Pressure Washer 039-8556-0 Use and Care Guide Congratulations on the purchase of your new pressure washer. In order to ensure you have the best possible experience please read through the

More information

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters TPI Corporation P.O. Box 4973 Johnson City, TN 37602 www.tpicorp.com FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters FSS-14 FSS-43 FSS-31 FSS-95 IMPORTANT SAFETY INFORMATION

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

52 BARSTOW CEILING FAN

52 BARSTOW CEILING FAN 52 BARSTOW CEILING FAN Owner s Manual Models #20519 If a problem cannot be remedied or you are experiencing difficulty with installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

Use and Care Manual. For Beverage Cooler RU

Use and Care Manual. For Beverage Cooler RU Use and Care Manual For Beverage Cooler RU 500 7081 619-01 Congratulations on your purchase. Choosing this appliance means you want all the benefits of state-of-the-art refrigeration technology, guaranteeing

More information

52 BAYTOWNE CEILING FAN

52 BAYTOWNE CEILING FAN 52 BAYTOWNE CEILING FAN Owner s Manual Models #20501 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.- 5

More information

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions 3119233 V.140529 General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS Spring/Summer:

More information

Garment Steamer Model SC620

Garment Steamer Model SC620 OWNER S MANUAL Garment Steamer Model SC620 For information or assistance: EURO-PRO Corporation 178 West Service Rd. Champlain, NY 12919 1-800-798-7398 www.euro-pro.com IMPORTANT SAFETY INSTRUCTIONS When

More information

USER MANUAL SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067

More information

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly. TABLE OF CONTENTS Machine Components Safety Precautions Machine Set Up Machine Operation Machine Maintenance & Storage Troubleshooting Technical Specifications Parts Lists Wiring Diagram 1 2 3 3-4 5 6

More information

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG) WET/DRY VACUUM Operating Instructions (ENG) MODEL: T1 y QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO 9001. Read these instructions before operating the machine.

More information

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Federal regulations require all ceiling fans with light kits manufactured or imported after January 1, 2009, to limit total wattage consumed by the

More information

BEFORE OPERATING THE MACHINE: WARNING

BEFORE OPERATING THE MACHINE: WARNING BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this

More information

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE XAACT Xtract 200 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00018 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

English. Your Model Number is: HD1500 IMPORTANT

English. Your Model Number is: HD1500 IMPORTANT Your Model Number is: HD1500 IMPORTANT Attention Valued Customer: The serial number of your machine and date of purchase is necessary information to facilitate warranty claims and the ordering of replacement

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

2002 METAL FORM MFG. Form No: CCIOM/03

2002 METAL FORM MFG. Form No: CCIOM/03 CELLCOOL Evaporative Cooling Module Installation Operation and Maintenance Manual PLEASE READ ENTIRE DOCUMENT BEFORE PROCEEDING WITH INSTALLATION Energy Saver has a policy of continuous product improvement

More information

Owner s Manual RD432-0 Chemical Controller

Owner s Manual RD432-0 Chemical Controller Owner s Manual RD432-0 Chemical Controller Table of Contents I. Introduction page 2 A. Water Chemistry page 2 B. Safety page 3 C. System Components page 4 D. Specifications page 7 E. Controller Panel Descriptions

More information

2003 METAL FORM MFG. FORM NO: PCIOM/03

2003 METAL FORM MFG. FORM NO: PCIOM/03 PRECOOLER PRE-CONDENSER EVAPORATIVE COOLERS Installation, Operation, and Maintenance Manual Energy Saver (ES) has a policy of continuous product improvement and reserves the right to change designs and

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Saving energy and creating healthy, comfortable environments No. II-450 Date July, 2015 DRIVE-THRU UNIT 3 AIR CURTAIN SERIES DTU03 for outdoor use

More information

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5 TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance

More information

Portable Dehumidifier

Portable Dehumidifier Portable Dehumidifier OPERATING INSTRUCTIONS HMT-D30-A Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A HMT-D45E-A HMT-D70E-A 3058080 V.161115 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable

More information

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications... 4 TABLE OF CONTENTS Technical specifications... 1 Warranty... 2 Important precautions Read first!... 3 Safety features and electrical power information... 5 Parts and diagram list... 6 Assembly and operation

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS Owners Manual Port-A-Cool Products and Accessories and Küül Pads Cooling Media are manufactured by Port-A-Cool, LLC P.O. Box 2167 709 Southview Circle Center, TX 75935 Phone 936-598-5651 800-695-2942 www.port-a-cool.com

More information

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters TPI Corporation P.O. Box 4973 Johnson City, TN 37602 www.tpicorp.com FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters FSA-14 FSA-43 FSA-31 FSA-95 IMPORTANT SAFETY

More information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE. Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

ELSTON 52 CEILING FAN

ELSTON 52 CEILING FAN ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -

More information

owner s manual & parts list

owner s manual & parts list AVIATOR owner s manual & parts list This equipment is intended for commercial use only. 3009AF 3009AF-W 1753 Blake Avenue Los Angeles, CA 90031 (800) 338-EDIC Or (323) 660-1635 Fax (323) 667-0144 BEFORE

More information

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output Operating Instructions & Parts Manual 1RKT2, 1RKT3, 1RKT4, 1RKT5, 1RKT9 and 1RKU2 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the

More information

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings 2 Installation Instructions 3 Wiring Instructions 3 Outdoor

More information

FOR YOUR SAFETY IMPORTANT WARNING. installation and service manual evaporative cooler model series H & O H76353A

FOR YOUR SAFETY IMPORTANT WARNING. installation and service manual evaporative cooler model series H & O H76353A 5H76353A May, 2010 installation and service manual evaporative cooler model series H & O c 9900100 us FOR YOUR SAFETY The use and storage of gasoline or other flammable vapors and liquids in open containers

More information

52 STRATHMERE CEILING FAN

52 STRATHMERE CEILING FAN 52 STRATHMERE CEILING FAN Owner s Manual Models #20341 If a problem cannot be remedied or you are experiencing difficulty with installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF INSTRUCTIONS FOR OPERATION AND CARE OF LITTLE Splint Compact Splint Pan Model LS-1 Whitehall Manufacturing is a Member of Acorn Engineering s Family of Companies. 6900-191-001 July 2010 Introduction...3

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

Electric Pressure Washer

Electric Pressure Washer Electric Pressure Washer S1700 039-8574-6 Owner s Manual If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664). PLEASE

More information

Electric Pressure Washer

Electric Pressure Washer Electric Pressure Washer S1900 039-8575-4 OWNER S MANUAL If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664) PLEASE

More information

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W Energy- Saving Mode Window AC 12000BTU MODEL: 12000BTU 11.2 Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry. CONGRATULATIONS on your purchase of a Viper product, and welcome to the V.I.P. family. We appreciate your business and will do everything in our power to keep you happy with your purchase for many years

More information

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE ITEM #0294980 0294981 TILGHMAN CEILING FAN Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. MODEL #WCK52LMW5N WCK52NWZ5N Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.) Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment

More information

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD Port-A-Cool unit series 2000 Pneumatic Owner s Manual FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD manufactured by port-a-cool, llc PORT-A-COOL unit OWNERS MANUAL PNEUMATIC MODELS PAC2K36AD, PAC2K24AD,

More information