MODEL FTGF2P (240 VAC)
|
|
- Baldwin Morris Shaw
- 5 years ago
- Views:
Transcription
1 SUMMARY MODEL FTGF2P (240 VAC) OPTIONS SELECTION At the back of the thermostat, there are two selection switches to set yor preference. 1 2 Temperatre in C or F. Time in 12 or 24 hors. TO SET TIME AND DAY Press on DAY, HOUR and MIN bttons to adjst time and day. TO RECORD THE (COMFORT) SETPOINT TEMPERATURE Select chosen setpoint temperatre by sing or btton. Press on btton (2 to 3 seconds) ntil icon appears on display. TO RECORD THE (ECONOMIC) SETPOINT TEMPERATURE Select chosen setpoint temperatre by sing or btton. Press on btton (2 to 3 seconds) ntil icon appears on display. CHECKING GROUND FAULT CIRCUIT INTERRUPTER (GFCI) Adjst the setpoint temperatre ntil heating indicator ( ) appears on display. Press on TEST btton. The test is conclsive if the warning light (GFI) on thermostat is ON and power to the load is ct-off ( remain on display thogh). If these events do not occr, check the installation. Press on RESET btton to reset the GFCI. OPERATING MODES To select an operating mode, se MODE btton. AUTO: Rns the program. or shows temperatre setting and can temporarily override yor programming p to the next program. MAN: Maintains the selected temperatre. or changes the temperatre setting.
2 INSTALLATION This thermostat is designed to control electric floor-warming systems. The resistive load mst not exceed 4000 watts 240 VAC (16.7 A). The thermostat is eqipped with a grond falt circit interrpter (GFCI) and therefore the isolation of the line and load are reqired for operation. A certified electrician mst install the thermostat. PARTS INCLUDED - One (1) FTGF2P (240 VAC) thermostat - Two (2) 6-32 screws - For (4) solderless connectors (for copper wire) - One (1) Temperatre sensor with a 15 foot extension TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean and free from obstrctions.
3 1) Connecting wires and monting thermostat Connect the rear thermostat wires to the power spply and to the load sing solderless connectors for copper wires. See schematic diagram. 240 V Line Psh the excess wire back into the electrical box to prevent interference with the thermostat. Secre the thermostat sing two (2) 6-32 screws. Once the thermostat is properly installed, retrn power to heating system. 240 VAC Note 1: All cables and connections mst conform to the local electrical code. WARNING: Special CO/ALR solderless connectors mst be sed when connecting with alminm condctors. 2) Connecting temperatre sensor wire Connect the temperatre sensor wire to the two lower screws of the terminal block at the back of the thermostat (no polarity needs to be respected). The sensing probe shold be placed in a representative heat area for maximm system perfomance. 240 VAC The sensing probe shold be centered between the wires in the mat. The temperatre sensor wire cannot cross any heater wires and the sensing probe mst not be directly ON or adjacent to a heating wire. Power-p
4 To power p thermostat: When power is applied for the first time, the display mst show the time 00:00, the floor temperatre and the manal mode icon ( ). Other information might show p on the display if installation is defective or does not comply with the instrctions. The warning light (GFI) mst be off. L0 will appear if temperatre is below 0 C (30 F), temperatre probe defective (open) or not connected. Also, the heating indicator will be present on display and the relay will be closed (crrent going in the load). HI will appear if temperatre higher than 60 C (140 F) or temperatre probe shorted. Checking grond falt circit interrpter (GFCI) Adjst the setpoint temperatre ntil heating indicator ( ) appears on display. Press on TEST btton. The test is conclsive if the warning light (GFI) on the thermostat is ON and power to the load is ct-off. If these events do not occr, check the installation. Press on RESET btton to reset the GFCI. If the GFCI test fails: Check the load wires. The thermostat mst be in heating mode to carry ot the test (heating indicator ON). OPERATING MODES The FTGF2P has two (2) operating modes. MANUAL ( ) The GFCI test shold be carried ot monthly. If the test fails, ct off the electric power to the heating system and call cstomer service or retrn the thermostat to yor spplier for verification. If the warning light comes on dring normal operation, ct off power to the heating system and have an electrician verify the installation. This mode allows yo to maintain a constant temperatre on the floor. 1- To activate this mode, press on Mode btton to display the icon. 2- Set the desired temperatre sing the bttons or select the pre-programmed or or settings. (To select the setting, press on and simltaneosly.) AUTOMATIC ( ) This mode exectes yor own programming. To activate this mode, press on Mode btton to display the icon. The or icon indicates which temperatre setting is sed. Also, the icon of the program nmber will be shown.
5 Memory back-p In the event of a power failre, an internal circit will maintain the programming and the time. Only the time will have to be set if a power failre is more than 6 hors. PROGRAMMING Programming the time and day 1-Set the time sing the Hor and Min bttons. 2-Set the day sing the Day btton. Programming the Comfort, Economic and Vacation settings The Comfort, Economic and Vacation settings respectively represent the temperatres that yo wish to have dring the day, at night or while yo are away at work, or while yo are away for an extended period. To program yor settings a) To program the Comfort temperatre, select the desired degree sing the bttons and press the btton ntil the icon is displayed (approx. 3 seconds). b) To program the Economic temperatre, select the desired degree sing the bttons and press the btton ntil the icon is displayed (approx. 3 seconds). c) To program the Vacation temperatre, select the desired degree sing the bttons and press on the and bttons simltaneosly ntil the icon is displayed (app. 3 seconds). d) Press the Mode btton to exit this fnction and retrn to the normal operating mode. Schedle programming The FTGF2P allows 4 setting changes for each day of the week. There are no presset programs.the programs are tailored to perfectly adapt to yor life style. The principle is very simple. For each day, enter the time at which yo wake p (P1), the time yo leave for work (P2), the time yo arrive back home (P3) and the time yo go to bed (P4).
6 Program Mode Time Wake-p time Leaving time Retrn time Bed time NOTE : For temperatre increases (Prog. 1 and 3), allow at least 1 hor. If yo have lowered the temperatre dring the night and yo wake p at 7:00 AM, change the setting to 6:00 AM. a) To Program yor Schedle 1- Press on PGM btton to access the programming mode. 2- Press on Day btton to select the day to be programmed. Yo can select all days of the week by pressing on Day btton for 3 seconds. 3- Press on PGM btton to select program 1, 2, 3 or Press on Hor and Min bttons to program the time. 5- When yo have completed yor programming, press on Mode btton to exit this fnction. b) To Erase a Program : Select the program sing PGM and Day bttons, and press on Clear btton. The time field displays --:-- when the program is inactive. c) Example 1 : Comfort period from 7:00 AM to 10:30 PM Economy period from 10:30 PM to 7:00 AM Identical schedle for all days of the week. 1- Press on PGM btton to access the programming mode. 2- Press on Day btton 3 seconds to select every day of the week. 3- Press on Hor btton to enter 7:00 AM, Prog. 1 ( ). 4- Press on PGM btton again to select Prog. 2 ( ), and press on Hor and Min bttons to enter 10:30 PM. 5- Press on Mode btton to exit this fnction. d) Example 2 : Comfort period: Monday to Friday from to and from 5:00 PM to 10:00 PM. Schedle/Day MON. TUES. WED. THU. FRI. SAT. SUN. PROG. 1 7:30 AM 7:30 AM PROG PROG. 3 PROG PM PM NOTE : It is faster to program the same schedle for every day and then modify the exception days.
7 1- Press on PGM btton to access the programming mode. 2- Press on Day btton 3 seconds to select every day of the week. 3- Press on Hor and Min bttons to enter Prog. 1, ( ). 4- Press on PGM btton to select Prog. 2 ( ) and Hor and Min bttons to enter. 5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM). NOTE : When making modifications, make sre yo are in the right program. To modify the Satrday and Snday schedles: 6- Press on Day btton ntil SA or SU is displayed. 7- Press on PGM btton to select Prog. 1 ( ) and Hor and Min bttons to enter 7:30 AM. 8- Press on PGM btton to select Prog. 2 ( ) and then Clear btton to erase it. 9- Press on PGM btton to select Prog. 3 ( ) and then Clear btton to erase it. 10- Press on PGM btton to select Prog. 4 ( ) and then Hor and Min bttons to enter 11:00 PM. 11- Press on Mode btton to exit this fnction. Temporary or permanent temperatre bypass This operation allows yo to temporarily modify the floor temperatre while yo are in the Atomatic mode. Simply press on or bttons to select the desired temperatre, or the or btton to select the Comfort or Econo settings yo have programmed. This temperatre will be maintained ntil the beginning of the next programmed schedle. Yo can also switch to the Vacation setting for a prolonged absence by pressing on and at the same time. The display will show icon. In that case, the temperatre bypass is permanent. To retrn to the normal operating mode, press on Mode btton. If yo wish to immediately retrn to the programmed settings, press on Mode btton twice. CHARACTERISTICS Model: FTGF2P (240 VAC) Spply: 240 VAC, 50/60 Hz Load: 16.7 A maximm (Resistive only) Power: 4000 watts 240 VAC Grond falt circit interrpter (GFCI): Class A (5 ma TRIP LEVEL) Approvals: CSA / C, US Display range: 0 to 60 C (32 to 140 F) Setting range: 5 to 40 C (40 to 104 F) Comfort defalt setting: 28 C (82 F) Econo defalt setting: 18 C (64 F) Storage: -20 to 50 C (-4 to 120 F)
8 WARRANTY NUHEAT INDUSTRIES LIMITED. ONE (1) YEAR LIMITED WARRANTY This prodct is warranted against material defects and workmanship in normal se for a period of one year, from the date of the original prchase from athorized dealers. Dring this period, NUHEAT will repair or replace the prodct with a new or of eqivalent qality at NUHEAT S option, withot charge, any prodct proven defective in normal se. Warranty does not cover transportation costs. Nor does it cover a prodct sbjected to misse or accidental damage. This warranty does not cover the cost of installation, removal or reinstallation. This limited warranty is in lie of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall NUHEAT be liable for conseqential or incidental damages reslting from installation of this prodct. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclsion or limitation of incidental or conseqential damages, so the above exclsions or limitations may not apply to yo. This warranty gives yo specific legal rights and yo may also have other rights which vary from state to state. The defective prodct and the original sale receipt mst be retrned to the original dealer or shipped pre-paid, insred and addressed to: NUHEAT INDUSTRIES LIMITED. CANADA 1689 Cliveden Ave. Delta, B.C. V3M 6V5 Web site: If yo have any qestions concerning the installation or programming of this prodct, please call or technical assistance at WARM (9276), Monday to Friday between 6:00 AM and 5:00 PM Pacific time.
SOLO User Guide. Description. Installation. Programmable Dual Voltage Thermostat 240 V (120 V)
SOLO User Guide Programmable Dual Voltage Thermostat Description The SOLO thermostat is designed to control the temperature of a floor heating system for both 120-volt and 240-volt applications. The thermostat
More informationProgrammable Electronic Thermostat
INSTRUCTION MANUAL Programmable Electronic Thermostat We thank you for trusting Aube technologies and hope that you will be entirely satisfied. For any questions concerning the TH141A-HC-28 progammable
More informationWARNING Important Safety Information
2 Installation Premier Series Non-Programmable Thermostats MODEL 3300 Mlti-Stage 3 Heat / 2 Cool Ato Changeover Conventional and Heat Pmp Before Installing or Operating, PLEASE READ ALL INSTRUCTIONS 1
More informationstock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit
stock code 5265 FIXING GUIDE 09 Thermonet underfloor heating programmable thermostat kit 2.9 TEMPORARY TEMPERATURE BYPASS The temperature setting can be temporarily adjusted when in Automatic mode. Use
More informationPhone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.
Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via
More informationLoudspeakers Line Isolator System
Commnications Systems Lodspeakers Line Isolator System Lodspeakers Line Isolator System www.boschsecrity.com Provides redndant lodspeaker loops for pblic address and voice alarm systems Dramatically redces
More informationIMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE
IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE Please note: The TH106 comes factory set in baseboard mode (even though the Honeywell Owner s Guide incorrectly reflects a factory setting of fan mode).
More informationQuickStat-TC Installation & Operation Manual
QuickStat-TC Installation & Operation Manual General Information A F Use of this Manual This manual covers the installation and operation of the Raychem QuickStat-TC thermostat and must be used with the
More informationHot Water Dispenser. Important: Read and save these instructions.
Part No. 3184330 nstallation nstrctions/use and Care Gide Hot Water Dispenser mportant: Read and save these instrctions. MPORTANT: nstaller: Leave nstallation nstrctions with homeowner. Homeowner: Keep
More information6 Advanced Programming
6 Advanced Programming 6.1 Program Codes This chapter provides the Program Codes table which smmarizes the wide variety of available programming operations, along with a description and comments. Additional
More informationREAD AND SAVE THESE INSTRUCTIONS
FANMATE FEATURING EZClip TM by MAXXAIR VENTILATION SOLUTIONS SUPERIOR RAIN PROTECTION OPTIONAL BUG SCREEN ASSEMBLY AND FOR MODELS: SMOKE 755, WHITE 855, AND BLACK 955 READ AND SAVE THESE INSTRUCTIONS WARNING:
More informationType UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button
USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1
More informationControl Panel-Based Alarm System
Control Panel-Based Alarm System Installation Programming Operating Keep this manal safe for reference and ftre maintenance Introdction Contents Thank yo for choosing the Yale Wireless Alarm System. This
More informationFAS 420 Series Aspirating Smoke Detectors LSN improved version
Fire Alarm Systems FAS 420 Series Aspirating Smoke Detectors LSN improved version FAS 420 Series Aspirating Smoke Detectors LSN improved version www.boschsecrity.com Connectable to the fire panels FPA
More informationBuderus Oil Boilers. Buderus G115 & G215.
Bders Oil Boilers Bders G115 & G215 Bders residential oil boilers are designed to extract and deliver more heat from every fel dollar, and are available in higher otpts at less cost per BTU. www.boschheatingandcooling.com
More informationFMC 210 DM Double Action Call Points
Fire Alarm Systems FMC 10 DM Doble Action Call Points FMC 10 DM Doble Action Call Points www.boschsecrity.com Adjstment after alarm triggering Individal identification thanks to atomatic or manal detector
More informationSC Installation, Operation & Application Guide
SC 5211 2-Stage Heat Pump Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat Pump Systems Large Display With Backlight Selectable
More informationFAP-420/FAH-420 Automatic Fire Detectors LSN improved version
Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical
More informationAuto Drain Valve. Longer life & Higher resistance to foreign matter. AD402-A Series CAT.ES40-65A. Improved foreign matter resistance
Ato Drain Valve RoHS Longer life & Higher resistance to foreign matter Improved foreign matter resistance Catching of foreign matter is redced with no sliding part. Diaphragm type Poppet type Shape prevents
More informationT8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE
T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE 1 69-1557 Welcome to the world of comfort and energy savings with your new Honeywell programmable thermostat. Your new programmable thermostat
More informationFAP-420/FAH-420 Automatic Fire Detectors LSN improved version
Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire s LSN improved version FAP-420/FAH-420 Atomatic Fire s LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical sensors with
More informationT4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE
T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE 69-1396-1 Features Digital temperature sensing and control for energy efficient precision operation. Flexibility of 5-1-1
More informationSC Installation, Operation & Application Guide
SC 5811 2 Heat/2 Cool Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat/2-Stage Cool Systems 2-Stage Heat Pump Systems Large
More informationFAP 520 Automatic Fire Detectors LSN improved version
Fire Alarm Systems FAP 520 Atomatic Fire Detectors LSN improved version FAP 520 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Modern, ltra-flat design Smooth, easily-cleaned detector
More informationMicroelectronic Programmable Thermostat Owner s Manual. 1 J.H Form Number
Microelectronic Programmable Thermostat Owner s Manual 1 J.H. 5-94 Form Number 69-0819 Table of Contents Programmed Recovery... 3 Programming Your Thermostat... 6 Programming... 6 Program Schedule... 7
More informationParts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins
Table of Contents Parts Diagram........................................................... 1 Icon Descriptions......................................................... 2 Specifications...........................................................
More informationOwner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS
Owner s Manual Model COMMERCIAL TM BACKLIT DISPLAY HVAC SERVICE PARTS Heat/Cool & Heat Pump 7-Day Programmable Digital Thermostat Use with most Heat Pump Systems: 2-Heat, 2-Cool Stages: 2-Heat, 2-Cool
More informationB9512G Control Panels
Intrsion Alarm Systems B9512G Control Panels B9512G Control Panels www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Spports
More informationLC4 Ceiling Loudspeaker Range
Commnications Systems LC4 Ceiling Lodspeaker Range LC4 Ceiling Lodspeaker Range www.boschsecrity.com Innovative CosCone fll range driver Excellent speech and msic reprodction Unrivalled opening angle for
More informationLA1 UMx0E Metal Column Loudspeakers
Commnications Systems LA1 UMxE Metal Colmn Lodspeakers LA1 UMxE Metal Colmn Lodspeakers www.boschsecrity.com Good speech intelligibility and backgrond msic reprodction For applications where directivity
More informationGEC Low-frequency Horn Strobes
Fire Alarm Systems GEC Low-freqency Horn Strobes GEC Low-freqency Horn Strobes Silence the horn while strobes flash Evacation tone Use the SperSlide featre for easy testing Wide voltage range; 16 to 33
More informationELECTRONIC THERMOSTAT
110-792B 7/12/01 8:28 AM Page 1 ELECTRONIC THERMOSTAT Owner s Manual MODEL 8554 5-2 Day Programmable Thermostat 110-792B 7/12/01 8:28 AM Page 2 OWNER S MANUAL TABLE OF CONTENTS ENERGY STAR Program Information............................................................
More informationCC600PB Solution 144 Control Panel
Intrsion Alarm Systems CC600PB Soltion 144 Control Panel CC600PB Soltion 144 Control Panel www.boschsecrity.com 16 on-board zones (expandable to 144 wired or wireless), partitionable to 8 areas with 256
More informationSC Installation, Operation & Application Guide
SC 5812 3 Heat/2 Cool Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 3-Stage Heat/2-Stage Cool Systems 3-Stage Heat Pump Systems Large
More informationLC4 Ceiling Loudspeaker Range
Commnications Systems LC4 Ceiling Lodspeaker Range LC4 Ceiling Lodspeaker Range www.boschsecrity.com Innovative CosCone fll range driver Excellent speech and msic reprodction Unrivalled opening angle for
More informationLA1 UMx0E 1 Metal Column Loudspeakers
Commnications Systems LA UMxE Metal Colmn Lodspeakers LA UMxE Metal Colmn Lodspeakers www.boschsecrity.com Good speech intelligibility and backgrond msic reprodction For applications where directivity
More informationType UDG, UCG, UTN, USG
INSTRUCTIONS Type UDG, UCG, UTN, USG 57004C 09/12 (KPA) The thermostat is an electronic on/off thermostat for temperature control by means of an NTC sensor located either externally or internally within
More informationProgrammable Heat-Pump Thermostat TAYSTAT 540
Programmable Heat-Pump Thermostat TAYSTAT 540 OWNER S GUIDE FEATURES The Trane Co. sells comfort systems. Comfort is achieved through matching the correct equipment and controls. This thermostat is designed
More informationUser s Guide. DH E RS D/BW Smart Programmable Digital Thermostat for Heated Floors
User s Guide DH E RS D/BW Smart Programmable Digital Thermostat for Heated Floors @ If you are viewing this guide online, please note that this product has been slightly modified since its introduction.
More informationTH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.
TH146-P-2H1C Installation Guide Programmable 2H1C Controller Removable Connector * Removable Connector * TH146-P User Console CT280-2H1C Control Module AC144-03 Outdoor Temperature Sensor * To remove a
More information7-Day. Digital Thermostat. residential. & 2-cool
Digital Thermostat residential THERMOSTAT T1100FS 7-Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 Heat & 2 Cool Stages 7-Day Programmable 4 Settings/Day Auto Changeover 5 minute Built-In
More informationD2212BE Control Panel
Intrsion Alarm Systems DBE Control Panel DBE Control Panel www.boschsecrity.com Eight (maximm) on-board points Eight sers and passcodes with three athority levels Two programmable on-board relay otpts
More informationOwner s Manual MODEL 8555
110-793B 7/11/01 3:29 PM Page 1 ELECTRONIC THERMOSTAT Owner s Manual MODEL 8555 7 Day Programmable Thermostat 110-793B 7/11/01 3:29 PM Page 2 OWNER S MANUAL TABLE OF CONTENTS ENERGY STAR Program Information............................................................
More informationFor Quick Set-Up go to Page 14
Talking Thermostat Model VT3000 Guide SmartWay Solutions, Inc. US Patent 6,608,560 & 7,62,253 For Quick Set-Up go to Page 4 Model VT3000, a universal thermostat for use on most Gas or Electric, Conventional
More informationOwner s Manual. 5+2 Day Programmable Digital Thermostat
Model Air Conditioning & Heating 5+2 Programmable Digital Thermostat 1-Heat & 1-Cool Heat Pump Compatible Battery or System Powered Backlit Digital Display Fahrenheit or Celsius Service Filter Indicator
More informationTH232-AF-230 Installation Instructions
Installation Instructions 230 V Base Parts One (1) thermostat One (1) floor sensor One (1) wall plate Guidelines Turn off power to the heating system at the main power panel to avoid electrical shock.
More informationUSER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat
WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool
More informationLH1 UC30E Music Horn Loudspeaker
Commnications Systems LH1 UC3E Msic Horn Lodspeaker LH1 UC3E Msic Horn Lodspeaker www.boschsecrity.com Excellent speech and msic reprodction Two way system Attractive ABS hosing Provisions for internal
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series
Premier Series MODEL 5000 USER MANUAL 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including
More informationOWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference
5100 Premier Series 7-Day Programmable 2-Heat / 2-Cool Heat /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages
More information1 For All Programmable Digital Thermostat. Meets Residential California Title 24
OWNER'S MANUAL P/N P374-1100FM 1 For All Programmable Digital Thermostat 72 74 Am I2:00 AUTO 70 unts Flush to the Wall 7 Day Programmable 4 Time Periods per Day Auto Changeover Large, Easy To Read Display
More informationMagicStat CT3300 Programmable Thermostat
MagicStat CT3300 Programmable Thermostat Installation and Programming Instructions Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model
More informationTH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.
TH146-N-2H1C Installation Guide Non-programmable H/C Controller Removable Connector * Removable Connector * TH146 User Console CT280-2H1C Control Module AC144-03 Outdoor Temperature Sensor * To remove
More informationTETRA Secury System funkwerk TSS: The future of professional mobile communication.
TETRA Secry System fnkwerk TSS: The ftre of professional mobile commnication. The TETRA-based radio alarm system with telephony integration and precise localisation Fnkwerk Secrity Commnications Secrity.
More informationASFP On-site guide to installing fire-stopping
ASFP On-site gide to installing fire-stopping ASFP On-site gide to installing fire-stopping In this gide fire-stopping incldes cavity barriers, penetration seals for services and linear joint seals. The
More informationLH1 UC30E Music Horn Loudspeaker
Commnications Systems LH1 UC3E Msic Horn Lodspeaker LH1 UC3E Msic Horn Lodspeaker www.boschsecrity.com Excellent speech and msic reprodction Two way system Attractive ABS hosing Provisions for internal
More informationProgrammable 5-2 Day Digital Thermostat
Programmable 5-2 Day Digital Thermostat 1 STAGE HEAT COOL THERMOSTAT TOTALINE 72 72 prog run off set Tu Heat I2:00 next SINGLE STAGE HEAT PUMP COMPATIBLE (Does not control auxiliary heat) Separate programs
More informationCT2800 Programmable Thermostat
CT2800 Programmable Thermostat INSTALLATION AND PROGRAMMING INSTRUCTIONS Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically
More informationUSER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat
MODEL 2000NC USER MANUAL Builder Series 5-2 Day Programmable Single Stage /Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single
More informationOn initial power up the thermostat will guide you through set up procedure for the following:
Operating Guide: for the Warmup 3iE Programmable Thermostat INTRODUCTION Your thermostat s default screen is the Home Screen. This screen displays important information such as the time, current floor
More informationFPA 1000 UL Analog Addressable Fire Panel
Fire Alarm Systems FPA 1000 UL Analog Addressable Fire Panel FPA 1000 UL Analog Addressable Fire Panel www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt in Ethernet connector
More informationWireless Thermostat (WTS10) Keypad Operation Guide
Keypad Operation Guide This Guide is intended to provide basic instructions for operating the thermostat from its on-board user interface prior to it being commissioned into the wireless ControlScope network.
More informationThermostats. Digital Programmable. GEAppliances.com
GEAppliances.com Digital Programmable Thermostats Owner s Manual & Installation Instructions RAK148P2 RAK164P2 Configuration Mode...8 9 Important Safety Information... 2 Installation Instructions... 4
More information5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT
Heating & Cooling TSTATCCPQ501 PROGRMABLE DIGITAL THERMOSTAT USER INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW THERMOSTAT SINGLE STAGE HEAT & COOL THERMOSTAT 72 Tu I2:00 72 prog 5+2
More informationB5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.
Intrsion Alarm Systems B5512 Control Panels B5512 Control Panels www.boschsecrity.com Spports a combination of p to 48 hardwired or wireless points for installation flexibility and p to 4 areas with perimeter
More informationFireray5000-EN. Fire Alarm Systems Fireray5000-EN. Extended monitoring range. Up to 2 detectors per system controller
Fire Alarm Systems Fireray5000-EN Fireray5000-EN www.boschsecrity.com Extended monitoring range Up to 2 detectors per system controller Two pairs of fire and falt relays (one per detector) Transmitter
More informationOwner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM
Owner s Manual Model S1-THEH21P5S HVAC SERVICE PARTS TM Heat Pump 5+2 Programmable Digital T h e rm ostats t a t BACKLIT DISPLAY Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool Control up
More informationUser s guide. Multiple programming Electronic thermostat
SYSTÈME QUALITÉ CERTIFIÉ - REGISTERED QUALITY SYSTEM User s guide STE402P+ Multiple programming Electronic thermostat Energy Verified For further information or to consult this guide online, please visit
More informationAMAX panel Intrusion Alarm Systems AMAX panel hardwired zones / 2 areas / 64 user codes
Intrsion Alarm Systems AMAX panel 2100 AMAX panel 2100 www.boschsecrity.com 8 hardwired zones / 2 areas / 64 ser codes 3 x 256 events log stamped with date and time On-board voice dialer Macro fnctionality
More informationModel 8710 Wireless Thermostat. Owner s Manual. Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS
Model 8710 Wireless ermostat Owner s Manual Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS Improved Comfort Your wireless thermostat provides automatic control
More informationICP-AMAX3-P2-BE Intrusion panel, fr/de/nl/pt
Intrsion Alarm Systems ICP-AMAX3-P2-BE Intrsion panel, fr/de/nl/pt ICP-AMAX3-P2-BE Intrsion panel, fr/de/nl/pt www.boschsecrity.com 32 zones / 8 areas / 128 ser codes On-board voice dialer Macro fnctionality
More informationProgrammable Thermostat
Programmable Thermostat with Humidity Control Auto Changeover Dual Power 7-Day, 5-2-Day, or 5-1-1- Day Programmable Configurable for Multiple Systems Large Display with Backlight Selectable Fahrenheit
More informationELECTRIC FIREPLACE OWNER S MANUAL
ELECTRIC FIREPLACE OWNER S MANUAL MODELS EL1346C 4001358 WARNING: If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury
More informationB465 Universal Dual Path Communicator
Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com Compatible with control panels sing Contact ID, SIA, Plse 3/1 or Plse 4/2 commnication
More informationB465 Universal Dual Path Communicator
Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com The B465 Conettix Universal Dal Path Commnicator converts the Pblic Switch Telephone
More information640 Series Advanced Remote Vehicle Security System
640 Series Advanced Remote Vehicle Security System WWW.ULTRASTARTERS.COM FCC/ID Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device
More information5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08
Digital Thermostat residential THERMOSTAT 5+2 DAY PROGRAMMABLE up to 1-heat & 1-cool PUMP Stages: 1-Heat, 1-Cool Battery or System Powered Back-Lit Digital Display Fahrenheit or Celsius Service Filter
More informationOwner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information
Model 8800 Universal Communicating Thermostat Owner s Manual Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS 61000762A 8800 Tstat Owners.indd 1 3/28/11 4:19:57
More informationWARNING Important Safety Information
Premier Series Programmable Thermostats MODEL 5000 1 2 3 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information Additional Operation Features
More informationCaution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.
Installation Guide: for the Warmup Tempo Digital Programmable Thermostat The world s best-selling floor heating brand Introduction The Tempo thermostat is designed to aid in the comfort of your home by
More informationT8131C Programmable Thermostat OWNER S GUIDE
/ T8131C Programmable Thermostat OWNER S GUIDE Weekday/Weekend Programmable Heat and/or Cool Thermostat and Mounting Plate 1 69-0908 1 69-0908-1 Welcome to the world of comfort and energy savings with
More informationB3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels.
Intrsion Alarm Systems B3512 Control Panels B3512 Control Panels www.boschsecrity.com Spports p to 16 points sing 8 on-board and 8 wireless points for installation flexibility with perimeter and interior
More informationLBB 1990/00 Plena Voice Alarm Controller
Commnications Systems LBB 1990/00 Plena Voice Alarm Controller LBB 1990/00 Plena Voice Alarm Controller www.boschsecrity.com Heart of the Plena Voice Alarm System EN 54 16 certified and EN 60849 compliant
More informationINSTRUCTION MANUAL P Heating and 1 Cooling
REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:
More informationOwner s Manual. Digital Thermostat
Model Air Conditioning & Heating Heat Pump 5+2 Day Programmable Digital Thermostat Control up to 2-Heat & 1-Cool Battery or System Powered Backlit Digital Display Auxiliary Heat Indicator Fahrenheit or
More informationB5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.
Intrsion Alarm Systems B5512 Control Panels B5512 Control Panels www.boschsecrity.com Spports p to 48 points sing a combination of hardwired or wireless points for installation flexibility and p to 4 areas
More informationOwners Manual. HTC621W 7-Day Programmable Thermostat 3600W. HTC625W 7-Day Programmable Thermostat 4000W
Owners Manual 7213110100R06 HTC621W 7-Day Programmable Thermostat 3600W HTC625W 7-Day Programmable Thermostat 4000W HTC627-347W 7-Day Programmable Thermostat 5200W Congratulations on your purchase of this
More informationSafety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.
Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these
More informationD2212B Control Panel. Intrusion Alarm Systems D2212B Control Panel. Eight on-board points. Up to 24 wired or wireless points
Intrsion Alarm Systems DB Control Panel DB Control Panel www.boschsecrity.com Eight on-board points Up to wired or wireless points Eight sers and passcodes with three athority levels Two programmable on-board
More informationFMC 420RW Single Action Call Points LSN improved
Fire Alarm Systems FMC 420RW Single Action Call Points LSN FMC 420RW Single Action Call Points LSN Alarm triggering by pressing the black marking or breaking the glass pane Protection against injry throgh
More informationT6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat
T6 Pro Hydronic Programmable Thermostat User Guide Package Includes: T6 Pro Hydronic Programmable Thermostat Floor sensor (model AQ12C20) UWP Mounting System Honeywell Standard Installation Adapter (J-box
More informationAir Pump Up to 800 gallons
Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationETN-24-HC21-PROG Econo-Vent
ETN-24-HC21-PROG Econo-Vent Owner's Manual - Installation and Operating Instructions Cat. G030121 Rev. 3.1 02.06 Meitav-tec Ltd (Contel group) Tel: 972-3-9626462 ax: 972-3-9626620 www.meitavtec.com - support@meitavtec.com
More informationI2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL
USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. Mo 72 74 AUTO HEAT 70 Heat Pump &
More informationTB8220U Commercial Programmable Thermostat OWNER S GUIDE
TB8220U Commercial Programmable Thermostat OWNER S GUIDE 63-2643 Contents Features... 3 Main Screen Selections... 4 Programming Heating and Cooling Schedule... 6 Operating the Thermostat... 10 Replacing
More informationInstallation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.
Installation Manual 000 Version.0 EXP-000 HBX Control s Inc. Control s Inc. HBX EXP 000 Version.0 HBX EXP-000 EXPANSION MODULE INTRODUCTION The EXP-000 is designed to be integrated with the HBX CPU-000
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION
MODEL 5100 USER MANUAL Compatible with low voltage multi-stage heat/cool systems with up to two stages of heating and two stages of cooling. READ ALL INSTRUCTIONS BEFORE PROCEEDING 1 2 3 4 5 6 7 CONTENTS
More informationELECTRONIC COMMUNICATING THERMOSTAT : P COOL AUTO. Owner's Manual
O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT : P DAY COOL AUTO Hold Prog Mode Fan OMNISTAT Owner's Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document
More informationFPA 1000 Analog Addressable Fire Panels
Fire Alarm Systems FPA 1000 Analog Addressable Fire Panels FPA 1000 Analog Addressable Fire Panels www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt-in Ethernet connector
More informationHEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION
E L E CT R I C DUCT HEATER FLIPPABLE EK SERIES SHOWN RH SERIES RH-W SHOWN RENEWAIRE ERV + ELECTRIC DUCT HEATER: A SINGLE-SOURCE SOLUTION RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME,
More information