iseries Model SL Water Source Heat Pump 6 to 10 Ton
|
|
- Aubrey Simon
- 5 years ago
- Views:
Transcription
1 iseries Model SL Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features SL Model 072, 096 and Models from 6 through 10 tons Horizontal and Vertical Configurations Cabinet Cabinetry is constructed using heavy-gauge, G90 galvanized steel Quiet Operation All panels are insulated with ½" thick, 1.5 lb./cu.ft. density micromat fiberglass insulation for both thermal insulation and noise reduction Serviceability All units are designed to be serviced from the front of the unit Insulated bulkheads (vertical configuration only) allow the unit to be serviced during operation Unit Configurations All units are available in horizontal, vertical configurations 1 of 24 Filter Racks Units come standard with a 1" filter rack and construction filter Fan Motor The standard motor for all SL series heat pumps is a belt drive motor Angle Section Supports Horizontal units are equipped with angle section supports for hanging the unit. Field supplied spring or rubber isolation must be installed to isolate the unit from the building structure Water Connections All water connections are heavy duty copper FPT fittings securely fastened to the unit corner post Refrigerant Circuit SL units are designed using the optimum combination of compressor, water and copper aluminum-fin evaporator coils with TXV to provide peak performance. R-410A refrigerant
2 Standard Features, Factory Installed Options, and Field Installed Accessories continued.. Copper Coax Coil Compressor Monitor Relay ( 2 required) TXV (Thermal Expansion Valve) Improves refrigerant management and efficiencies Phase Protection Monitor 75 VA Transformer Wire for 208 Volt Standard Range (WLS / Towers / Boiler) Optional Filter Rack A 2" four-sided filter rack and pleated MERV 8 filter is optional and greatly improves air filtration Unit Protection Module Each SV unit is factory provided with a Unit Protection Module (UPM) that controls the unit operation and monitors the safety controls that protect the unit The UPM interfaces with the thermostat or direct digital controller Water and Air coil freeze protection Condensate Overflow Sensor Brown-out Protection Low and High Pressure Protection Hot Gas Bypass Modulating Hot Gas Bypass Hot Gas Reheat Passive Dehumidification Waterside Economizer Warranty 5 year compressor limited warranty 1 year parts limited warranty Cupro-nickel Coil: Recommended in conditions anticipating moderate scale formation or in brackish water Factory and Field Installed Options Pump Interlock Relay Helps ensure the external flow/pump center operates when unit is operating Boilerless Control DuoGuard Evaporator Coil Tin Electro-Plated Copper Tubing with High-Tech Polymer Coated Aluminum Fins will protect the evaporator coil from all forms of corrosive elements in the airstream Extended Range Option Vertical units only, standard on horizontal units. Includes insulated piping 100VA Transformer Differential Pressure Switch Closed Cell Foam Insulation (Coming Soon) Fire Alarm Relay DDC Controls The factory and field installed DDC Controller is preprogrammed and installed in the unit with the Unit Protection Module The unit will operate in a 100% stand-alone control mode or connect to a Building Automation System (BAS) using open protocols BACnet, Modbus and N2 EMS Relay Energy management relay to tie into a building's energy management system Blower Monitor Relay 2 of 24
3 Model Nomenclature SL SL VT C - S B S I U A - X X T A X X X X X 1 X X X X 6 X Size Voltage /60/ /60/ /60/ /60/3 Cabinet Configuraon VT - Vercal HZ - Horizontal Motor HP (Belt Drive Only) A VT, HZ B VT C HZ, 120 VT D HZ AIR FILTRATION 1 - Standard Throw Away 3-2" 4 Sided Filter Rack with 1" Filter Open Economizer X - None E - Economizer With 3 Way Valve and Controls Water Flow Control Opon X - None Coax Opons C - Copper N - Cupro-Nickel x - No Condenser Water Connecons F - Front S - Side X - N/A Return Air Configuraon B - Back F - Front L - Le Discharge Air Configuraon T - Top F - Front R - Rear S - Straight Through Fan/Motor Opons B - Belt Drive Air Coil U - Uncoated D - DuoGuard Revision Level A - Current Controls X - Standard M - DDC - Mul-Protocol (BacNET, Modbus, N2) L - DDC - LonWorks Transformer 7-75 VA Standard VA Opon Refrigeraon Circuit Opons X - None H - Hot Gas Reheat - On/Off B - Hot Gas Bypass M - Modulang Hot Gas Reheat General Electrical Opons (up to 5 available per unit) A - EMS relay B - Blower Monitor Relay C - Compressor Monitor Relay D - Phase Monitor E - Pump/valve relay G - Boilerless control H - Differenal proving switch K - Fire Alarm Relay/Dual Power M - Wire to 208 V X - As default for non used electrical codes Applicaon T - TXV Opon G - EXTENDED RANGE W/ SCHRADER VALVE (Geothermal) Electric Heat X - None Cabinet Construcon A - G90 Steel / 1/2" Standard 1.5LB Dual Density Fiberglass C - G90 Steel / 1/2" Closed Cell Foam 3 of 24
4 AHRI/ANSI Capacity and Efficiency Data Models Water Flow (GPM) Water Loop Ground Water Ground Loop Cooling (86 F) Heating (68 F) Cooling (59 F) Heating (50 F) Cooling (77 F) Heating (32 F) Capacity (Btuh) EER (Btuh/W) Capacity (Btuh) COP Capacity (Btuh) EER (Btuh/W) Capacity (Btuh) COP Capacity (Btuh) EER (Btuh/W) Capacity (Btuh) COP Physical Data Description Unit Value Compressor Type (Qty 1) Reciprocating Reciprocating Scroll Refrigeration Charge Oz Max Water Working Pressure PSIG/kPa 450/ / /3100 Number of Refrigeration Circuits Evaporator Coil Coil Type Tube-Fin Tube-Fin Tube-Fin Air Coil Dimensions Vertical H x L 18 x 28 (2) 20 x 32.5 (2) 20 x 32.5 (2) Air Coil Dimensions Horizontal H x L 18 x 28 (2) 20 x 32.5 (2) 20 x 32.5 (2) Row(s) Motor & Blower Fan Motor Type/Speeds Belt Drive/1 Belt Drive/1 Belt Drive/1 Fan Motor HP 1 1 1/2 (Vertical Units) 2 (Horizontal Units) 2 (Vertical Units) 3 (Horizontal Units) Blower Wheel Size Dia. x W x Qty 12 x 12 x 1 12 x 12 x 1 12 x 9 x 2 Water Connection Type FPT FPT FPT Size 1" 1" 1 1/4" Water Coil Type Coaxial Coaxial Coaxial Coaxial Coil Volume (gal) gal Vertical Cabinet Nominal size of Standard Filter - 1" H x L 20 x 34.5 (2) 20 x 34.5 (2) 20 x 34.5 (2) Weight - Operating lbs Weight - Shipping lbs Horizontal Cabinet Nominal size of Standard Filter - 1" H x L 20 x 34.5 (2) 20 x 34.5 (2) 20 x 34.5 (2) Weight - Operating lbs Weight - Shipping lbs of 24
5 Operating Limits - Cooling & Heating Description Standard Unit Extended Range Option COOLING Minimum ambient air temperature F Maximum ambient air temperature F Minimum evaporator entering air db/wb F 68/57 68/57 Rated air coil entering air db/wb F 80/67 80/67 Maximum evaporator entering air db/wb F 95/85 95/85 Minimum water coil entering fluid temperature F Water loop typical coil entering fluid range temperature F 70/90 70/90 Maximum water coil entering fluid temperature F HEATING Minimum ambient air temperature F Maximum ambient air temperature F Minimum evaporator entering air db F Rated air coil entering air F Maximum evaporator entering air db F Normal water coil entering fluid range F Minimum water coil entering Fluid F 50 20* * antifreeze solution is required at these fluid temperatures. Electrical Data - Belt Drive Motor Compressor Total Unit w/ Belt Drive Motor Compressor Service Model Voltage Code Voltage/ Phase/Hz Voltage Min/Max QTY RLA (each) LRA (each) Motor Qty FLA Min Circuit Amps Max Fuse/ HACR Cold Winding Resistance (Ω) Single Phase: R-C Single Phase: S-C Three- Phase: Line-Line Run Capacitor (μf/v) /1/60 197/ / /3/60 197/ /3/60 414/ /1/60 197/ / / / / /3/60 197/ / / / /3/60 414/ / / / /3/60 518/ / / / /1/60 197/ / /3/60 197/ / / / /3/60 414/ / / / /3/60 518/ / / / * First value is for vertical configurations and second value is for horizontals. * Resistance value tolerance +/- 7%. All resistance values must be measured with compressor at room temperature.. 5 of 24
6 Blower Performance Drive Belt Motor Model Motor Sheave Rated Airflow Available External Static Pressure (in. wc. Wet coil and filter included) Closed Half Open 2, Open Closed Half Open 2, Open Closed Half Open 4, Open Horizontal Cabinet Corner Weights Configuration Left Hand Evaporator Right Hand Evaporator Model Unit Total Left Front* Right Front* Left Back Right Back Left Front* Right Front* Left Back Right Back Lbs kg Lbs kg Lbs kg * Front is control box end 6 of 24
7 SL Vertical Single Blower Large Commercial Unit Configurations Front Return Optional Blower Orientation ( ) Standard Blower Orientation Blower Access Blower & Motor Access Blower & Motor Access Condenser Water Out Condensate Drain Condenser Water In Blower Motor Orientation Controls, Compressors, Refrigeration Components Access Electrical Connections Top Supply (FFT) Rear Supply (FFR) Rear Return Blower Motor Orientation Condenser Water Out Condensate Drain Condenser Water In Blower Access Blower & Motor Access Blower Motor Orientation Blower Access Blower & Motor Access Optional Blower Orientation ( ) Controls, Compressors, Refrigeration Components Access Electrical Connections Top Supply (FBT) Front Supply (FBF) 7 of 24
8 SL Horizontal Large Commercial Unit Configurations Controls, Compressors Access Electrical Box Condensate Drain Electrical Connections Condenser Water Out Compressors, Refrigeration Components Access Condenser Water Out Compressors, Refrigeration Components Access Condenser Water In Condenser Water In Blower Motor Orientation Condensate Drain Blower & Motor Access Blower Motor Orientation Condensate Drain 072, 096 (SLS Only) 120 (SLS Only ) Overall Dimensions Model Unit of Measure Vertical Cabinet Horizontal Cabinet Width Depth Height Width Depth Height in mm in mm in All dimensions within +/ 0.125". Specifications subject to change without notice. 8 of 24
9 SL Vertical Dimensions and Connections Front Return p Orientation Standard Blower Orientation Rear Return Top Supply (FFT) Standard Blower Orientation Rear Supply (FFR) Optional Blower Orientation ( ) Top Supply (FBT) Front Supply (FBF) SL Vertical Dimensions and Connections Model Width Depth Height Distance Between Base Rails Top Supply: Supply Depth Top Supply: Supply Width Top Supply: Front to Supply Top Supply: Left Side to Supply Rear Supply: Supply Height Rear Supply: Supply Width Rear Supply: Top to Supply Rear Supply: Right Side to Supply SL Vertical Dimensions and Connections Continued Model A B C "R/A Bottom to Duct Water Out Water In Condensate Drain Width" D E "Condenser "R/A Duct Flange "Filter Rack Water Height" Height" Connections" Condensate Drain Connection "Recommended Replacement Filter Size - 1" "thick" '' FPT 3/4" FPT 20 x 34.5 (2) '' FPT 3/4" FPT 20 x 34.5 (2) /4'' FPT 3/4" FPT 20 x 34.5 (2) 9 of 24
10 SL Horizontal Dimensions and Connections 072, SL SL Horizontal Horizontal Dimensions Dimensions and and Connections Connections Model Width Depth Height A B C Cab End to Filter Rack Filter Rack Height R/ADuct Flange Height R/A Duct Width E Front to Water In F Water In Height SL Horizontal Dimensions and Connections Continued Model G H J K L M Front to Water Out Water Out Height Supply Width Supply Height Rear to Supply Distance b/t Supply Ducts Condenser Water Connections Condensate Drain Connection Recommended Replacement Nominal Filter Size - 1"" thick" '' FPT 3/4" FPT 20 x 34.5 (2) '' FPT 3/4" FPT 20 x 34.5 (2) /4'' FPT 3/4" FPT 20 x 34.5 (2) 10 of 24
11 SL Vertical - Service Clearances *Blower Wheel/Housing 18" Minimum 24" Optimum Blower *Blower Motor Sheave/Pulley/Belt Access 18" Minimum 24" Optimum Compressor Accesss and Electrical/Control Access 36" Minimum Compressor Electrical Control Box * Rear Return Air Pattern shown. For Front Return Air, blower motor and blower housing access is on the LEFT HAND SIDE of the unit SL Horizontal - Service Clearances Electrical/Compressor Access 36" Minimum Electrical Control Box Air Coil Compressors Blower Blower Motor Compressor/Refrigerant Access 36" Minimum 11 of 24
12 SL072 Cooling Performance Data - Full 2300CFM Entering Water Temp F Water flow GPM Pressure Drop (FOH) Pressure Drop (PSI) Ent. Air db/wb, F Total Sensible Ht. Rej. Unit kw EER 75/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / of 24
13 SV007 (300 CFM) Capacity Data SL072 Heating Performance Data - Full 2300CFM Entering Water Temp F Water flow GPM Pressure Drop (FOH) Pressure Drop (PSI) Ent. Air db/wb, F Total Ht. Abs. Unit kw COP of 24
14 SL096 Cooling Performance Data - Full 2800CFM Entering Water Temp F Water flow GPM Pressure Drop (FOH) Pressure Drop (PSI) Ent. Air db/wb, F Total Sensible Ht. Rej. Unit kw EER 75/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / of 24
15 SL096 Heating Performance Data - Full 2800CFM Entering Water Temp F Water flow GPM Pressure Drop (FOH) Pressure Drop (PSI) Ent. Air db/wb, F Total Ht. Abs. Unit kw COP of 24
16 SL120 Cooling Performance Data - Full 4000CFM Entering Water Temp F Water flow GPM Pressure Drop (FOH) Pressure Drop (PSI) Ent. Air db/wb, F Total Sensible Ht. Rej. Unit kw EER 75/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / of 24
17 SL120 Heating Performance Data - Full 4000CFM Entering Water Temp F Water flow GPM Pressure Drop (FOH) Pressure Drop (PSI) Ent. Air db/wb, F Total Ht. Abs. Unit kw COP of 24
18 Antifreeze Correction Antifreeze Type Antifreeze % Cooling Heating EWT 90 Deg.F EWT 30 Deg. F Total Cap. Sens. Cap Power Htg. Cap Power WPD Correction Factor EWT 30 F Water Propylene Glycol Methanol Ethanol Ethylene Glycol Sound Data Model Octave Band Sound Power Levels db, re Watts Center Frequency - Hz Overall A weighted overall (dba) ARI-260:2001 (100hz-10kHz) VT HZ * Data is based on blower only manufacturer's data. * Overall calculated using Hz octave bands. 18 of 24
19 Field Installed Accessory - Duct Mounted Electric Heaters 208/230V Kilowatt Heater - 208/230V Part Number Nominal Dimensions (inches) Duct Flange Connection (Inches) Min. CFM Required Duct Heater 5 kw x x Duct Heater 5 kw x x Duct Heater 5 kw x x Duct Heater 5 kw x x Duct Heater 10 kw x x Duct Heater 10 kw x x Duct Heater 10 kw x x Duct Heater 15 kw x x Duct Heater 20 kw x x It is recommended to use a seven (7) conductor cable for thermostat interface. In fiber glass duct systems, a metal sleeve MUST be used to support the heater. It is required for the duct mounted heater to have an independent power supply. 19 of 24
20 Field Installed Option - Communicating Thermostats Model/Order Number: Description: TSTBT4H2CPHM - KA TSTBT4H2CP - M - KA Features: 4 stages of heat, 2nd stage latching, Low temp alert, High temp alert, Inefficient heating and cooling operation alerts Application: Communicating Thermostat Kit w/ Humidity Control Communicating Thermostat Kit Warranty: 5 Year Limited Warranty Communicating Thermostat Accessories Model/Order Number: Description: ZONB - OTS M - - A ZONB - LAS M - - A Features: Wired Outdoor Temperature Sensor Leaving Air and/or Return Air Sensor Field Installed Option - 24V Conventional Thermostat Model/Order Number: Description: Features: TSTBM3H2CPH6W - A Smoke detection, Semi-wireless, Filter change/clean notification, Programmable fan Application: Warranty: If smoke is detected in ducting, unit will stop, preventing circulation of smoke to other rooms. 5 Year Limited Warranty 24V Conventional 24V Thermostat Conventional Accessories Thermostat Accessories Model/Order Number: Description: TSTBM - RRS - - TW - A TSTBM - OTS - - TW - A Features: Wireless Remote Room Sensor Thermostat Wireless Outdoor Temperature Sensor Field Installed Option - Smoke Detector Model/Order Number: Description: SMKB A SMKB - 02FST A Features: Duct Smoke Detector 2 Foot Air Sampling Tube Application: Warranty: If smoke is detected in ducting, unit will stop, preventing circulation of smoke to other rooms. Manual reset is required which let's customer know there was an occurrence. 5 Year Limited Warranty on Parts 20 of 24
21 Field Installed Option - Bosch Humidifiers Model/Order Number: Description: HUMBXSBP12H6 - - A HUMBXLBP17H6 - - A Features: Small Bypass Humidifier, Manual Summer/Winter Damper, Humidistat included Large Bypass Humidifier, Manual Summer/Winter Damper, Humidistat Included Application: 12 Gallons per Day 17 Gallons per Day HUMBSBP-12H6--A HUMBSBP-17H6--A Warranty: 1 Year Limited Warranty on Humidifer Pad 5 Year Limited Warranty on Assembly Field Installed Option - Bosch Photo Catalytic Oxidizer (PCO) Model/Order Number: Description: PCOB A PCOB A Features: 9" UVC Light Bulb 14" UVC Light Bulb Application: up to 1500 CFM units or House up to 2000 sq. ft. up to 2400 CFM units or House up to 4700 sq. ft. Warranty: 1 Year Limited Warranty on Bulb 2 Year Limited Warranty on Ballast 5 Year Limited Warranty on Assembly Field Installed Option - Bosch Fresh Air Damper (FAD) Model/Order Number: Description: FADB A FADB A FADB A Size 4" Fresh Air Damper 5" Fresh Air Damper 6" Fresh Air Damper Features: Variable Capacity Control (settings from 0 to 100 of available CFM) Variable Position Damper Included Variable Position Control Included Vent Hood with Screen Included Application: A minimum of 70 CFM of fresh air from outside up to 1300 sq. ft. home A minimum of 110 CFM of fresh air from outside up to 2100 sq. ft. home A minimum of 150 CFM of fresh air from outside up to 3000 sq. ft. home Warranty: 5 Year Limited Warranty on Assembly 21 of 24
22 Factory Installed Options and Applicable Models Description 100VA Transformer DuoGuard Coil coating Closed Cell Insulation EMS Relay Blower Monitor Relay Compressor Monitor Relay (1) Phase Protection Monitor Fan/Pump Interlock Relay Boilerless Control Differential Pressure Switch Fire Alarm Relay Wire for 208 Volt Hot Gas Bypass Hot Gas Reheat Modulating Hot Gas Reheat (2) DDC 7.03 with LonWorks Card DDC Option Water Side Economizer Applicable Model Numbers 4 Sided MERV-8 2" Filter Rack Extended Range (3) (1) Unit sizes require 2 each of these items. You must use a quantity of 2 when you price them. (2) When you order HGRH, you need to order Duct Stat # and Leaving Air Temperature Sensor # (not required when ordering DDC). (3) Vertical only. 22 of 24
23 Specification Guide 1.0 General Furnish and install water source heat pumps as indicated on the plans with capacities and characteristics as listed in the schedule and the specifications that follow. The units shall be manufactured in an ISO 9001:2000 certified facility. 2.0 Horizontal/Vertical Water Source Heat Pumps Units shall be designed to operate throughout the range of entering fluid temperature of 50 F to 100 F in the cooling mode and 50 F to 80 F in the heating mode. Units shall have an operating range of 50 F to 110 F in the cooling mode and 25 F to 80 F in the heating mode when equipped with the optional extended range package. Equivalent units from other manufacturers can be proposed provided approval to bid is given 10 days prior to bid closing. All equipment with a nominal capacity of 135,000 BTUH Total Cooling or lower must be listed in the current AHRI Applied Equipment Directory under the AHRI Standard AHRI/ISO , WLHP, GWHP and GLHP certification points. All equipment in this section must meet or exceed the DOE mandated minimum EER s and COP s as listed in ASHRAE Basic Construction A. Units shall have the air flow arrangement as shown on the plans. If units with these arrangements are not used, the contractor supplying the water source heat pumps is responsible for any extra costs incurred by other trades and must submit detailed mechanical drawings showing ductwork requirements and changes or relocation of any other mechanical or electrical system. If other arrangements make servicing difficult the contractor must provide access panels and clear routes to ease service. The architect must approve all changes 10 days prior to bid. B. All units shall have stainless steel drain pans to comply with this project s IAQ requirements. Painted steel or plastic material shall not be permitted. C. All water source heat pumps shall be fabricated from heavy-gauge sheet metal steel. All interior surfaces shall be lined with 1/2 inch thick, multi density acoustic insulation. Insulation within the air handling section shall not have any exposed edges. All insulation must meet NFPA 90A and be certified to meet the GREENGUARD Indoor Air Quality Standard for Low Emitting Products. One blower access panel and two compressor compartment access panels shall be removable with supply and return air ductwork in place. D. Unit compressors shall have rubber isolators to reduce transmission of vibration to the structure. E. All units shall have a factory installed two sided filter rack capable of accepting one inch filters. Units shall have a 1 inch thick throwaway type glass fiber filter as standard. The filter rack shall incorporate a 1 inch duct flange. The contractor shall purchase one spare set of filters and replace factoryshipped filters upon completion of start-up. F. Cabinets shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. Supply and return water connections shall be copper FPT fittings and shall be securely mounted flush to the cabinet allowing for connection to a flexible hose without the use of a back-up wrench. Water connections which protrude through the cabinet shall not be allowed. G. Condensate overflow protection shall be provided as standard for horizontal units Fan and Motor Assembly A. The fan(s) shall be belt driven DWDI forward curved type with dynamically balanced wheel(s). The fan motor(s) shall be 1725 or 3450 RPM 56 frame sealed ball bearing type. The motor(s) shall be permanently lubricated and have thermal overload protection. B. The fan and motor assembly must be capable of overcoming the external static pressures as shown on the schedule. External static pressure rating of the unit shall be based on a wet coil. Ratings based on a dry coil shall NOT be acceptable. 23 of Refrigerant Circuit Units shall use R-410A refrigerant. Units that use R-22 refrigerant shall not be allowed. All units shall have a factory sealed and fully charged refrigerant circuit with the following components: A. Hermetic compressor: Hermetic reciprocating, or scroll compressors shall be specifically designed for R-410A refrigerant and shall be internally sprung (if reciprocating), externally isolated and with thermal overload protection. B. Refrigerant metering thermal expansion valves. C. Finned tube refrigerant to air heat exchanger. Refrigerant to air heat exchangers shall utilize enhanced aluminum fins and rifled copper tube construction rated to withstand 600 PSIG refrigerant working pressure. All air coils shall have non-ferrous aluminum end plates. Option for refrigerant to air coils to have Duo-Guard coating for enhanced protection against formicary and other corrosion. Copper tubes shall be tin coated and aluminum fins coated to pass 1000 hour ASTM B117 salt fog testing. D. Reversing valve. Reversing valves shall be four way solenoid activated refrigerant valves which shall fail to the heating operation should the solenoid fail to function. Reversing valves which fail to the cooling operation shall not be allowed. E. Coaxial (tube in tube) refrigerant to water heat exchanger. Refrigerant to water heat exchangers shall be of copper inner water tube and steel outer refrigerant tube design rated to withstand 600 PSIG working refrigerant pressure and 400 PSIG working water pressure. Shell and Tube style refrigerant to water heat exchangers shall be treated as pressure vessels and shall require refrigerant pressure relief valves piped to the exterior of the building. The contractor supplying the water source heat pumps with Shell and Tube heat exchangers shall be responsible for any additional installation costs. Brazed Plate water to refrigerant heat exchangers shall require additional centrifugal separators added to the supply water piping at each unit. Each separator shall have an automated clean out valve piped to a waste line. The contractor supplying water source heat pumps with Brazed Plate heat exchangers shall be responsible for any additional costs. Option for E: Cupro-Nickel water coil The refrigerant to water heat exchanger shall be of cupro-nickel inner water tube construction. F. Safety controls including both a high pressure and low pressure switch shall be provided on both circuits. Temperature sensors shall not replace these safety switches. See the controls section of this specification for additional information. G. Access fittings shall be factory installed on high and low pressure refrigerant lines to facilitate field service. H. Activation of any safety device shall prevent compressor operation via a lockout circuit, in the affected circuit. The lockout circuit shall be reset at the thermostat or at the contractor supplied disconnect switch. Units which may be reset at the disconnect switch only shall not be acceptable. Refer to solid state safety circuit below. A condensate alarm shall prevent both compressors from operating Electrical A control box shall be located within the unit and shall contain a transformer, controls for the compressor, reversing valve and fan motor operation and shall have a terminal block for low voltage field wiring connections. The transformer shall be rated for a minimum 75 VA. All units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 volts Solid State Safety Circuit All units shall have a solid-state UPM safety control circuit with the following features: 1. Anti-short cycle time delay on compressor operation. 2. Random start on power up mode. 3. Brown out/surge/power Interruption protection. 4. Low Pressure Switch 120 second bypass timer.
24 Specification Guide Continued 5. Shutdown on high or low refrigerant pressure safety switch. 6. Standard Evaporator Freeze Stat 7. Standard Condenser/Water Coil/Coaxial Heat exchanger Freeze Stat 8. Condensate overflow sensor will hard shut down upon first trip.. 9. Alarm output which closes for selectable dry contact closure or 24 VAC remote fault indication. 10. Alarm output selectable for constant output for general alarm notification, or pulse output for annunciation of the specific fault alarm. 11. Reset unit at thermostat or disconnect. 12. Automatic intelligent reset. Unit shall automatically reset after a safety shut down and restart the unit after the anti-short cycle timer and random start timer expire. Should a fault re-occur within 60 minutes after reset, then a permanent lockout will occur. Reset attempts shall be selectable for either 2 or 4 tries. 13. Ability to defeat time delays for servicing. 14. A light emitting diode (LED) to indicate safety alarms shall be provided for each circuit. The LED shall annunciate the following alarms: high refrigerant pressure, low refrigerant pressure, low water temperature, a high level of condensate in the drain pan, or brown out/surge/ power interruption. The LED will display each fault condition as soon as the fault occurs. If a permanent lockout occurs, then the fault LED will display the type of fault until the unit is reset. 15. UL listed, CUL listed, and RFI, ESD, and transient protected Options: A. Extra quiet construction: Optional compressor blankets shall be provided on units, for additional attenuation. B. Hot Gas Reheat: Units as noted on the schedule shall be equipped with optional Hot Gas Reheat (HGRH). HGRH shall be either on/off control or modulating as noted in the specifications. On/Off HGRH shall be controlled by a humidistat connected to the unit H terminal and shall start the unit in the reheat mode should the humidity be above set point once the thermostat control is satisfied. Cooling or heating requirements shall take precedent over HGRH. Modulating Hot Gas Reheat (MHGRH) shall be active during the cooling mode. A 0-10 VDC signal from a sensor located in the unit discharge air supply shall modulate the hot gas valve to maintain an adjustable preset leaving air temperature to the conditioned space. C. Hot Gas Bypass: For units as noted on the schedule, supply each unit with a UL listed and MEA listed modulating hot gas bypass valve with factory supplied and installed controls to prevent air coils from frost development by taking hot gas and bypassing the water coil and expansion device and reintroducing the hot gas into the refrigerant line prior to the air coil. The hot gas bypass valve shall maintain a minimum refrigerant suction pressure to allow for a light load cooling mode or a low entering air temperature cooling mode. D. Water Differential Switch. Prevents unit operation if there is no fluid flow. E. Water Side Economizer: water side economizer shall be completely installed at the factory, with condensate drain pan(s), motorized 3 way valve, aqua stat, and all internal electric controls. Water side economizer shall be rated at 400 psi and UL listed for application with the heat pump. F. Factory-installed control options: phase loss and reversal protection 3.0 Hose Kits All units shall be connected with hoses. The hoses shall be either 2 or 3 feet long, braided stainless steel, fire rated hoses complete with adapters. Non fire rated hoses are not acceptable. Optional ball valves with P/T ports, flow controller, Y strainer and electric valve shall be in included as specified in the schedule. 24 of 24
Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com
boschheatingandcooling.com 1 Greensource iseries Water Source Heat Pumps SV Model Made in Florida boschheatingandcooling.com 1 Replacement Water Source Heat Pump About the Bosch Group The Bosch Group has
More informationGreensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com
Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and
More informationDXair Pool Dehumidifiers
DXair Pool Dehumidifiers LV Series / to 6 Ton G-60 Galvanized The option-rich DXair LV Series pool dehumidifier has one of the smallest cabinets in the industry, making it a great choice for replacement
More informationEP Model. EP Model Water Source Heat Pump. ½ to 6 Ton
EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.
More informationGTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts
GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationGreensource Residential Geothermal Heat Pumps. Think Green Think Renewable Think. iseries: SV Model Split System. boschheatingandcooling.
Greensource Residential Geothermal Heat Pumps iseries: SV Model Split System boschheatingandcooling.com 1 boschheatingandcooling.com Think Green Think Renewable Think 1 Residential Geothermal Heat Pumps
More informationGUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers
GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationReinventing Energy Efficiency
Commercial WATER2AIR EC LARGE SERIES Reinventing Energy Efficiency www.fhp-mfg.com Environmental stewardship is a core philosophy for FHP Manufacturing from design to production to the reduction in our
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationwater to water heat pumps
AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationtechnical guide Water-Cooled Self-Contained Units
technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationProduct Data. Features/Benefits Carrier s Aquazone WSHPs are an efficient, compact alternative for all boiler/tower and retrofit applications
Product Data Aquazone 50PCH, PCV, PCD007-070 Compact Water Source Heat Pumps with Puron Refrigerant (R-410A) 1 / 2 to 6 Nominal Tons TM Single-package horizontally and vertically mounted water source heat
More informationWater-Cooled Self-Contained Units
CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationProduct Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps
Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE
More informationAVAILABLE WITH ENERGY SAVING ECM MOTOR
WATER SOURCE HEAT PUMP WSHC/WSHX HORIZONTAL Water Source Heat Pumps 3/4 thru 5 Tons HIGHLY EFFICIENT HIGH PERFORMANCE QUIET OPERATION STANDARD FEATURES 100% Factory run tested. All units operate with environmentally
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationMODULE-AIRE VERTICAL PACKAGE UNITS MB SERIES MB SERIES. Energy Wise HVAC Equipment
Energy Wise HVAC Equipment FHP MANUFACTURING 601 N.W. 65th Court Fort Lauderdale, FL 33309 (954) 776-5471 (800) 776-5529 Fax www.fhp-mfg.com VERTICAL PACKAGE UNITS MODULE-AIRE FHP brings to the market
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationLV Split Systems Water Source Heat Pump
LV Split Systems Water Source Heat Pump 1½ to ton boschheatingandcooling.com and coolin g.c om 1 The option-rich LV Split Systems offer lower operating costs, space-saving flexibility and quiet comfort,
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationEC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons
E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationGreensource Residential Water Source Heat Pumps
TM boschheatingandcooling.com 1 Greensource Residential Water Source Heat Pumps Si Series: CE Model The Si Series CE Model contains a two stage compressor, variable speed ECM motor and comes with a variety
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump
More informationMC SERIES. Optional reverse cycle heating Takes full advantage of building diversity
FHP brings to the market a first in R-410A large capacity modular reverse cycle units. The many features and energy efficiency of the MC Series make them the ideal choice for either new construction or
More informationPAR5. Product Specifications
TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced
More informationGreensource Residential Geothermal Heat Pumps. Invisible Comfort. Si Series: CE Model. boschheatingandcooling.com
Greensource Residential Geothermal Heat Pumps Si Series: CE Model Invisible Comfort The Si Series CE Model contains a two-stage compressor, variable speed ECM motor and comes with a variety of standard
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationRev. 2/13
Rev. 2/13 2 EC Series Table of Contents MODEL NOMENCLATURE...3 FHP MANUFACTURING...3 ADVANTAGES OF FHP s TECHNOLOGY...3 LARGE EC SERIES MODELS 072 360...3 FEATURES...3 Cabinet...3 Quiet Operation...4 Serviceability...4
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationSECTION WATER-SOURCE UNITARY HEAT PUMPS
SECTION 23 81 46 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph
More informationLM Split Systems Water Source Heat Pump
LM Split Systems Water Source Heat Pump 2 to ton boschheatingandcooling.com and coo g.c om 1 The fully featured LM Split Systems include a standard two-stage scroll compressor and an ECM (Electronically
More informationLV Model Water Source Heat Pump
LV Model Water Source Heat Pump 1/2 to 6 ton boschheatingandcooling.com and coolin g.c om 1 The option-rich, water-to-air LV offers one of the smallest cabinets in the industry, making it a great choice
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationUP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationEP Model Water Source Heat Pump
EP Model Water Source Heat Pump ½ to Ton Equipped with added standard features, a stronger, quieter cabinet and improved durability along with a variety of options providing additional energy efficient
More informationManufacturer Update 2014 IGSHPA
Bosch FHP Commercial Manufacturer Update 2014 IGSHPA Ø LV Single Stage Split System Heat Pump Ø LM Two-Stage High Efficiency Packaged Heat Pump Ø New Extended Warranty Options Chilton Stewart National
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationSECTION WATER-SOURCE UNITARY HEAT PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationEngineered for flexibility and performance
Enfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant Vertical Models LVC Standard Range & LVW Geothermal Range Unit Sizes 072 290 (6 to 25 Tons) R-410A Refrigerant Catalog 1109-5 Engineered
More informationGenesis Compact (GC) Series Submittal Data
SERIES: HZ: UNIT OF MEAS: LANGUAGE: GC - R22 50 SI ENGLISH Genesis Compact (GC) Series Submittal Data Models GCH/V 018B - 060B 50Hz - R22 English Language/SI Units REVISION: 03/13/03 ** MODEL DECODER GC
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationCA Model Water Source Heat Pump
CA Model Water Source Heat Pump ¾ to ½ ton boschheatingandcooling.com andcoo i g.c om The CA console provides high performing heating and cooling in a compact size when space and access is at a premium.
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationProduct Data. Fig. 1 - Unit 50VR -A
50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged
More informationSpaceKeeper Console (SKC)
SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationProduct Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic
Product Data Aquazone 0RHE006-060 Water Source Heat Pumps Horizontal Unit 0 Hz, CE Mark R-407C 1.to13.7NominalkW(Cooling) 1.8 to 16. 8 Nominal kw (Heating) TM Copyright 2004 Carrier Corporation Single-Package
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationDSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data
DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal
More informationN4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationN4H4. Product Specifications
14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationProduct Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving
Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE
More informationES Model Water Source Heat Pump
ES Model Water Source Heat Pump 2 to ton boschheatingandcooling.com 1 The ES Model features a two-stage scroll compressor, an ECM constant airflow blower motor and enhanced features that provide the best
More informationFrom 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction
From 230 tons to Water-Source eat Pump Products Premium Performance Environmentally Friendly Superior Construction Water-Source eat Pump Products Small Packaged Water-Source eat Pumps (1/2 to 30 tons)
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More information