ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Size: px
Start display at page:

Download "ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer."

Transcription

1 ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away from a single wall is. a. close to the wall b. away from the wall c. exactly where it should be d. too short to be used 2. An 800 gallon water tank shall have a drain pipe at least in diameter. a. 1 inch b. 1-1/2 inches c. 2 inches d. 2-1/2 inches 3. The minimum allowed size of a 1/16" sloped building drain is inches. a. 1-1/4 b. 2 c. 3 d The minimum air gap for a fixture with an effective open of 3/4", located close to a wall is inch(s). a. 1/2 b. 2

2 c. 1-1/2 d. 2-1/2 5. A water closet shall not be set any closer than inches from its center to a wall. a. 12 b. 16 c. 15 d A water heater relief valve shall not. a. discharge on a floor b. discharge into an indirect waste receptor c. have an air cap in the discharge piuping d. have a trap in the discharge piping 7. Bedpan washers and clinical sinks shall connect to the drainage and vent system in accordance with the requirements of a. a. lavatory b. water closet c. bidet d. service sink 8. The diameter of hole bored in joists shall not exceed the depth of the joist. a. 1/3 b. 1/2 c. 1/4 d. 1/8 9. Grab bars with a circular cross section shall have an outside diameter of inch (32 mm) minimum and 2 inches (51 mm) maximum. a. 1 b. 1-1/4

3 c. 1-1/2 d. 1-3/4 10. Sheet copper used for general applications shall not weigh less than. a. six ounces per square foot. b. twelve ounces per square foot c. four pounds per square foot d. four ounces per square foot 11. A drainage stack of two branch intervals receiving the discharge of 30 dfu s, shall be a minimum of inches diameter. a. 2 b. 2.5 c. 3 d A 4 inch copper pipe, passing through a fire-resistance-rated wall may be protected. a. by filling the annular space with concrete b. by an approved firestop system c. by either a or b d. by neither a or b 13. The strainer openings of a shower waste strainer shall be a minimum of inches. a. 1/8 b. 1/4 c. 3/8 d. 1/2 14. CPVC solvent cement shall be in color and conforming to ASTM F 493 when primer is used. a. orange b. red

4 c. purple d. green 15. A circuit vented branch serving four or more water closets and connecting to a drainage stack that receives the discharge from upper horizontal branches shall be provided a vent. a. individual b. relief c. common d. yoke 16. A pipe that is located inside a building and conveys storm water from the roof to the sewer is a? a. Leader b. Conductor c. roof drain d. Storm drain 17. At a velocity of 8 feet per second, a manifold serving a demand of 12 gpm must have a minimum diameter of inches. a. 1/2 b. 3/4 c. 1 d. 1-1/4 18. A pipe that makes an angle of 45 degrees is considered pipe by the code. a. horizontal b. vertical c. obtuse d. angled 19. A yoke vent must be used to vent horizontal offsets of drainage stacks when there are or more branch intervals above the offset. a. 10

5 b. 8 c. 6 d A factory requiring 5 drinking fountains may substitute with bottled water dispensers. a. 1 b. 2 c. 3 d For water service pipe, a standard for galvanized steel pipe is. a. ASTM B43 b. ASTM B 75 c. ASTM A 53 d. ASTM F A factory bathroom with 3 water closets (1.6 gpf), 6 urinals (1gpf), five lavatories and a floor drain has how many drainage fixture units. a. 25 b. 27 c. 30 d Each fixture drain shall connect to the horizontal branch drain being circuit vented. a. horizontally b. vertical to horizontal c. on top of the horizontal drain d. any of the above 24. The minimum capacity of a sewage pump connected to a 2 inch discharge pipe shall be gpm. a. 21

6 b. 30 c. 46 d The minimum air gap for a fixture with an effective open of 1/2", located away from a wall is inch(s). a. 1/2 b. 2 c. 1-1/2 d Building sewers 8 inches and larger must be provided with manholes located not more than feet apart. a. 100 b. 200 c. 75 d According to Table the required flow rate for a bathtub is gpm. a. 4 b. 8 c. 3 d The maximum discharge to a relief vent shall be dfu. a. 2 b. 4 c. 12 d A fixture with a 1-1/4 inch drain has drainage fixture units. a. 2

7 b. 4 c. 1 d A vent terminal shall not be located closer than feet above the top of an openable window. a. 2 b. 4 c. 6 d Hand operated metering faucets shall remain open for seconds minimum. a. 10 b. 15 c. 20 d A 1-1/2 inch "P" trap with slip joints may be used as a cleanout for a maximum inch drain pipe. a b. 1-1/2 c. 2 d. 2-1/2 33. A fixture with a 2 inch drain has drainage fixture units. a. 2 b. 4 c. 3 d Waste stacks serving more than 10 branch intervals must be provided with a relief vent, with which the upper end shall be connected to the vent stack through a wye not less than feet above the floor.

8 a. 1.5 b. 2 c. 3 d Grease interceptors shall conform to any of the following except. a. PDI G101 b. ASME A c. ASME A d. NSF A cast iron mechanical joint coupling for hubless pipe and fittings shall comply with. a. CISP 310 or ASTM C1277 b. ASTM C564 or CAN/CSA B602 c. ASTM C 310 d. ASME A A hose connection vacuum breaker may be used as a backflow preventer for liquids. a. low hazard b. high hazard c. either a or b d. neither a or b 38. Plastic water service pipe shall terminate within feet inside of the point where the pipe penetrates an exterior wall or slab on grade. a. 2 b. 5 c. 8 d PVC primer must be in color. a. red

9 b. green c. purple d. yellow 40. Pipe applied vacuum breakers shall be installed not less than inches above the flood level rim of the fixture served. a. 2 b. 4 c. 6 d Floor drains are not require in. a. commercial kitchens b. public restrooms c. second floor condominiums units d. public coin operated laundries 42. The maximum flow rate for a hand held shower is 80 psi. a. 1.5 b. 2.5 c. 2.2 d Condensate piping of condensing appliances shall maintain a minimum horizontal slope of not less than unit vertical in twelve units horizontal. a. 1/8 b. 1/6 c. 1/4 d. 1/2 44. Shower and tub-shower combination valves and master thermostatic mixing valves shall be equipped with a means to limit the maximum setting of the valve to degrees F. a. 110

10 b. 115 c. 120 d Commercial food grinders shall conform to. a. ASSE 1009 b. ASSE 1008 c. ASTM 502 d. ASTM 502-A 46. A gravity sewer test must maintain 10 foot of head for minutes. a. 10 b. 5 c. 15 d When a bathtub outlet is not used with a shower, the shower waste outlet strainer must have a minimum diameter of inches. a. 1-1/2 b. 2 c. 2-1/2 d The space between the wall and the grab bar shall be inches. a. 1-1/2 b. 1-3/4 c. 2 d. 2-1/4 49. The minimum size fixture water supply pipe for an flush valve urinal is. a. 1/2" b. 3/4"

11 c. 1" d. 1-1/4" 50. Vents exceeding feet shall be increased by one nominal pipe size for the entire developed length of the vent pipe. a. 10 b. 20 c. 30 d A shower compartment with one side 30 inches shall not be less than inches on the adjacent side. a. 24 b. 36 c. 32 d The front of accessible lavatories and sinks shall be inches (865 mm) maximum above the floor, measured to the higher of the rim or counter surface. a. 30 b. 31 c. 32 d According to Table the required water pressure for a temperature controlled shower is psi. a. 25 b. 8 c. 15 d The maximum allowable temperature of wastewater discharged into a sewer is. a. 100

12 b. 120 c. 140 d Solvent cement for PVC plastic pipe shall conform to the following except. a. is permitted to be used both, above and below ground b. must be used with a primer that conforms to ASTM F 656 c. must be applied only to the male portion of the connection d. shall not be purple 56. A clearance in front of accessible bathtubs extending the length of the bathtub and inches (760 mm) minimum in depth shall be provided. a. 56 b. 59 c. 30 d A stack vent handling 125 dfu s with a developed length of 35 feet shall be inches minimum diameter. a. 2 b. 2.5 c. 3 d The water supply connection to a beverage dispenser must be protected by a/an. a. backflow preventer conforming to ASSE 1022 b. an air gap c. either a or b d. beverage dispensers do not require backflow prevention 59. A branch vent, 50 feet in developed length, serving a 3" drain, must be at least inches in diameter. a. 1-1/2

13 b. 2 c. 2-1/2 d Where a vent stack connects to a 4" building drain, the connection shall be located downstream of the drainage stack and within a distance of of the drainage stack. a. 3 feet b. 40 inches c. 4 feet d. 24 inches 61. Plumbing fixtures are. a. required to be third party certified b. required to be third party tested c. not required to be third party certified d. not required to be third party tested 62. A circuit vent shall vent a maximum of traps. a. 2 b. 4 c. 6 d Shower linings shall turn up on all sides at least inches above the finished threshold. a. 1 b. 1.5 c. 2 d The minimum size fixture supply pipe, 40 feet from a 40 psi, for a single shower head is. a. 3/8"

14 b. 1/2" c. 3/4" d. 5/8" 65. The minimum vent size of a sewage pump sump with a pump capacity of 10 gpm is inches. a. 1-1/4 b. 1-1/2 c. 2 d. 2-1/2 66. Solder used on copper shall conform to. a. ASTM F 80 b. ASTM S 75 c. ASTM B 32 d. ASTM M Outdoor enclosures for backflow prevention devices shall comply with. a. ASSE 1056 b. ASSE 1045 c. ASSE 1055 d. ASSE An indirect waste pipe that exceeds feet in total developed length must be trapped. a. 1.5 b. 2 c. 3 d Subsoil drainage components are. a. required to be third party certified b. required to be third party tested c. not required to be third party certified

15 d. not required to be third party tested 70. A 20 ft. length of pipe with slope per foot of 1/4" will produce a drop of inches. a. 3 b. 4 c. 5 d Copper and brass pipe shall not be used if it contains more than an average of grains of hydrogen sulfide per 110 standard cubic feet of gas. a..3 b..03 c. 3 d Except for decorative appliances, an equipment shutoff valve shall be located within feet of the appliance. a. 2 b. 4 c. 6 d Unless otherwise approved, threaded fitting larger than inches shall not be used for gas piping. a. 4 b. 3 c. 5 d Adding height to a vent. a. increases the vent capacity b. decreases the vent capacity c. does not affect the vent capacity

16 d. will cause the appliance to back draft 75. A 1 inch diameter iron gas pipe shall be threaded with approximately threads. a. 8 b. 9 c. 10 d Using CSST, 2 psi natural gas, 1.0 pressure drop,.60 specific gravity, what is the minimum pipe size for a 199,000 gas water heater located 100 away from the meter. a. 13 b. 15 c. 18 d A category I appliance cannot be connected to vent whose effective area is times or greater than the appliance draft hood outlet area. a. 3 b. 5 c. 7 d The maximum design operating pressure for gas piping systems located inside a residence shall nor exceed psi unless the piping system is welded or in a ventilated chase. a. 1/2 b. 2 c. 5 d A 2 inch diameter iron gas pipe shall have approximately inche(s) threaded. a. 3/4 b. 7/8 c. 1

17 d. 1-1/2 80. The slope of a vent connector shall be upward at least inch per foot. a. 1/16 b. 1/8 c. 1/4 d. 1/2 81. The minimum test pressure for a specific gas piping system is times the working pressure a. 1-1/2 b. 2 c. 2-1/2 d A 3/4 steel gas pipe shall be supported at intervals not exceeding feet. a. 4 b. 5 c. 6 d /2 gas tubing shall be supported at intervals not exceeding feet. a. 4 b. 5 c. 6 d Screens over combustion air openings shall have a mesh size not less than inch. a. 1/8 b. 1/16 c. 1/4 d. 1/2

18 85. A btu equals the amount of heat required to raise the temperature of one lb. of water one degree F, therefore btu s are required to raise 10 lbs. water 60 degrees F. a. 60 b. 6 c. 600 d An employee must complete a form to claim federal income tax withholding allowances. a. 941 b c. I-9 d. W A water heater costs $400, tax is 8%, labor is $180 and overhead is 15%. What is the sales price needed to make 30% profit? a. $1113 b. $887 c. $841 d. $ The minimum age for hazardous occupations is. a. 16 b. 17 c. 18 d Which of the following is not a current asset? a. prepaid insurance b. cash c. building d. accounts receivable

19 90. An employee works 46 hours for the week, his straight time pay is $12.50/hour. What is his gross pay? a. $ b. $ c. $ d. $ The employee must pay 6.2% Social Security Tax, therefore the amount of SS tax withheld on a gross pay of $ would be $ a. $41.66 b. $4.17 c. $ d. $ Employers are required by law to. a. pay overtime for time worked over 40 hour per week b. provide lunch breaks c. limit the number of hours worked d. provide rest periods 93. How much is saved when a 1.5% discount is taken on a $23,678 invoice? a. $3.55 b. $35.17 c. $ d. $ If the yearly fuel cost to operate a water heater with an overall efficiency of 60% is $500 what would the savings be using an 80% efficient water heater? a. $125 b. $100 c. $80 d. $75

20 95. protects your business against loss due to fire, theft or weather related incidents. a. Property insurance b. Comprehensive insurance c. Life insurance d. vehicle insurance 96. Disabilities covered by the Americans with Disabilities Act include all the disabilities below except. a. hearing b. seeing c. breathing d. broken bones 97. A company has annual sales of $850,000 with $230,000 overhead. What is the percent overhead? a. 27% b. 32% c. 37% d. 18% 98. In order to cover employee bonuses totaling $45,000, how much more revenue is needed if your company is earning an average 20% gross profit? a. $90,000 b. $ c. $ d. $225, A water heater costs $475, tax is 8%, labor is $180 and overhead is 15%. What is the sales price needed to make 30% profit? a. $1113 b. $1260 c. $841 d. $796

21 100. A federal ID number (EIN) is required by al businesses except. a. a sole proprietor ship with no employees b. a partnership with no employees c. an S corporation d. a corporation with no employees

22 Answer Sheet 1. a. Table footnote a 2. b. Table d. Table 710.1(10 4. d. Table c d b a b ICC/ANSI 10. b c. Table 710.1(2) 12. c , exception 1 and b a b b. 202 definition of conductor 17. c. Table b. def horizontal pipe "less than" 19. d b c. Table d. Table a a. Table d. Table d a. Table b c. Table a

23 31. a ICC/ANSI 32. c exception c. Table c d a c. Table b c c c b. Table see footnote a 43. a c a c d a ICC/ANSI 49. b. Table d d d ICC/ANSI 53. d. Table c c c ICC/ANSI 57. b. Table c b. Add 1/2 pipe size when over 40 feet 60. b b. Table 303.4

24 62. d. 202 definition of circuit vent 63. c a. Table footnote a 65. a. Table c c d b. Table c. 71. a c a a. study vent Tables 75. c. Table b. Table 402.4(17) 77. c c. 79. c. Table c a d. Table a. Table c c. 86. d. 87. a. Profit and overhead are expressed as percentages of cost (15%+30%= 45%, Total cost = $612, sales price = total cost/(100%-% needed to cover profit and overhead) 88. c. 89. c. 90. b. 91. a

25 92. a. 93. c. 94. a. (60/80) x 500 = 375, = a. 96. d. 97. a /850000= d. 45,000/.20=225, a. Profit and overhead are expressed as percentages of cost (15%+30%= 45%, Total cost = $693, sales price = total cost/(100%- Minus % needed to cover profit and overhead),693/.55= a

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. The minimum air gap for a fixture with an effective open of 1/2", located away from a

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

STACKS AND STACK VENTS

STACKS AND STACK VENTS CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

CHAPTER 9 VENTS SECTION

CHAPTER 9 VENTS SECTION CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

1 Exam Prep Plumbing State Contractors Practice Exam 2

1 Exam Prep Plumbing State Contractors Practice Exam 2 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof. CHAPTER 9 VENTS SECTION 90 GENERAL run undiminished in size and as directly as possible from the building drain through to the open air above the roof. 90. Scope. The provisions of this chapter shall govern

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

A GUIDE TO PASSING THE PLUMBING EXAM

A GUIDE TO PASSING THE PLUMBING EXAM A GUIDE TO PASSING THE PLUMBING EXAM BASED ON THE INTERNATIONAL PLUMBING AND FUEL GAS CODES WRITTEN BY JOHN WHITE REVISED 2014 2007-2014 This manual is the sole property of Energy Marketing Services. No

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

ENERGY MARKETING SERVICES

ENERGY MARKETING SERVICES 1 IMPORTANT STUFF This manual has been designed as a supplemental aid for students preparing to take the Plumbing Exam based on the international codes. It is not intended to replace any manuals or material

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Special Requirements For Health Care Facilities

Special Requirements For Health Care Facilities Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2 CHAPTER 10 TRAPS AND INTERCEPTORS < 1001.0 Traps Required. Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.1, shall be separately trapped by an approved type

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural

More information

2015 UPC Chapter 8 Indirect Wastes RV

2015 UPC Chapter 8 Indirect Wastes RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia Pro Vent TM Guide to Design and Usage Provent Single System Handling Installation Corrosion Ease Simplicity Resistance IPMO Copyright (c) 2014, Pro Vent Systems Inc., plus *2016 Revisions ll Rights Reserved

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

APPENDIX L ALTERNATE PLUMBING SYSTEMS

APPENDIX L ALTERNATE PLUMBING SYSTEMS ALTERNATE PLUMBING SYSTEMS L 1.0 General. L 1.1 Applicability. The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

plumbing for greywater

plumbing for greywater plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of

More information

CHAPTER VI BUILDING PLUMBING

CHAPTER VI BUILDING PLUMBING CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems

More information

PLAN REVIEW SUBMITTAL GUIDE

PLAN REVIEW SUBMITTAL GUIDE PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

WATER HAMMER ARRESTORS & MISC. SPECIALTIES TABLE OF CONTENTS Pictorial Index Water Hammer Arrestors Certification Sizing & Placement Backwater Valves Typical Installations Trap Seal Primers Compliance Pressure & Flow Characteristics Typical Installations

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

Denotes a new question! Denotes a revised/revisited question. September 2009 General: General: 1) (Q) What does a contractor/permit holder have to supply for an inspection? (A) Section 107.2 of the NC Administrative Code states that it is the duty of the permit holder to provide access

More information

FIXTURES, FAUCETS AND FIXTURE FITTINGS

FIXTURES, FAUCETS AND FIXTURE FITTINGS CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL 401.1 Scope. This chapter shall govern the materials, design and installation of plumbing fixtures, faucets and fixture fittings in

More information

Plumbing Guidelines 2012 IBC/ANSI A

Plumbing Guidelines 2012 IBC/ANSI A Plumbing Guidelines 2012 IBC/ANSI A117.1-2009 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms and bathing facilities. It is not intended to replace

More information

PLUMBING INSTALLATIONS

PLUMBING INSTALLATIONS PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...

More information

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)* CHaPTeR 10 TRaPS and INTeRCePTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training 2012 Virginia Plumbing Code & VRC (Plumbing) Update Training ----------------------------- Henrico County Department of Building Construction and Inspections Introduction This presentation was prepared

More information

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA AMERICAN PLUMBING INSTITUTE 2015 33 CONTINUING EDUCATION PO Box 31131 Spokane, WA 99223-3018 www.apiceu.com 2009 UPC Definitions Code Course 4 hours Course # ID09143 (CODE) DISCLAIMER NOTE: This course

More information

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings Summary of Substantive Changes between the 2012 and 2018 editions of ASME A112.18.1/CSA B125.1 Plumbing Supply Fittings Presented to the IAPMO Standards Review Committee on May 6, 2013 General: The changes

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY a. Only potable water shall be supplied to plumbing fixtures used for drinking, bathing, culinary use or the processing of food, medical or pharmaceutical

More information

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

INSPECTION OF COMMERCIAL KITCHEN PLUMBING INSPECTION OF COMMERCIAL KITCHEN PLUMBING 801.1 SCOPE Food-handling establishments 2 - by John Williams, Jr. Plumbing Control Supervisor Onondaga County Water Environment Protection Commercial Kitchens

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION PC 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

APPENDIX A. A 3.2 Determine the elevation of the highest. A 3.3 Subtract the sum of loss in static pressure

APPENDIX A. A 3.2 Determine the elevation of the highest. A 3.3 Subtract the sum of loss in static pressure APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers

More information

Drain and Vent Systems 6 CE Hours

Drain and Vent Systems 6 CE Hours Drain and Vent Systems 6 CE Hours Wisconsin Contractors Institute N27 W23953 Paul Road, Suite 203 Pewaukee, WI 53072 www.wicontractorsinstitute.com 262-409-4282 What is the purpose of this course? The

More information

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC People Helping People Build a Safer World Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC Installation, Flexibility and Opportunity for Savings Lee Clifton, Senior Director of PMG Resources,

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX A - RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM 1 2 1/AC AC SS SS/CC

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX A - RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM 1 2 1/AC AC SS SS/CC CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX A - RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Adopting Agency BSC SFM HCD DSA OSHPD CSA DPH AGR DWR CA 1 2 1/AC AC SS SS/CC 1 2 3 4 Adopt

More information

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock. Plumbing Plumbing may be defined as practice, materials, and fixtures used in the installation, maintenance, and alteration of all piping, fixtures, appliances, and appurtenances in connection with sanitary

More information

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010 General: 1) (Q) Who enforces the cutting and notching requirements found in the plumbing code? (A) The plumbing inspector would question the contractor initially. A building inspector would either take

More information

C O D E S & A M M E N D M E N T S

C O D E S & A M M E N D M E N T S SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and

More information

Plumbing Technology/Plumber CIP Task Grid

Plumbing Technology/Plumber CIP Task Grid 1 Secondary Task List 100 DEMONSTRATE PERSONAL SAFETY IN THE TRAINING LABORATORY 101 Follow rules for fire safety. 102 Follow rules for housekeeping safety. 103 Follow shop rules. 104 Follow rules for

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Floor

More information

A. Section Joint Sealants: Seal fixtures to walls and floors.

A. Section Joint Sealants: Seal fixtures to walls and floors. SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

2009 IPC ,IMC Q &A ANDIFGC

2009 IPC ,IMC Q &A ANDIFGC 2009 IPC,IMC ANDIFGC Q &A TABLE OF CONTENTS PREFACE.... ix ABOUT THE INTERNATIONAL CODE COUNCIL...x IPC CHAPTER 1 SCOPE AND ADMINISTRATION...1 Section 101 General... 1 Section 102 Applicability... 1 Section

More information

Definitions UPC Code - Chapter 2 Definitions A-I

Definitions UPC Code - Chapter 2 Definitions A-I 2015 UPC Code - Chapter 2 Definitions A-I Definitions 201.1 Applicability. For the purpose of this code, the following terms have the meanings indicated in this chapter. 202.0 Definition of Terms. 202.1

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION224213.13 -COMMERCIAL WATERCLOSETS PART 1- GENERAL 1.1 SUMMARY Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. 1.2 ACTION SUBMITTALS Product Data: For each type of product.

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems Sewage Pumps & Systems GIANT Little Pump Company Guidelines for Sizing Sewage Pumps & Systems These guidelines cover the steps that need to be taken to accurately select the correct sewage pump and applicable

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what This practice exam will require you to have a calculator, pencil, scrap paper, a copy of the 2005 National Plumbing Code and will contain many similar questions as the current Plumbing Red Seal trade certification.

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

c. Direct or indirect?

c. Direct or indirect? ~ \ 1.) GENERAL a. Definitions: Chapter B Code References (1) Air-break Comm 81.01 (5) (2) Air-gap, drain system Comm 81.01 (6) (3) Flood level rim Comm 81.01(102) (4) sink Comm 81.01(105) (5) Indirect

More information

2015 MPC, MMC and IFGC Significant Changes

2015 MPC, MMC and IFGC Significant Changes 2015 MPC, MMC and IFGC Significant Changes Based on the 2015 Michigan Plumbing Code, (MPC), the 2015 Michigan Mechanical Code (MMC) and the 2015 International Fuel GaS Code (IFGC) Purpose This program

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

CHAPTER 4 FIXTURES WHAT FIXTURES ARE REQUIRED? SINGLE-FAMILY RESIDENCE

CHAPTER 4 FIXTURES WHAT FIXTURES ARE REQUIRED? SINGLE-FAMILY RESIDENCE PlumbingCode06_ch04 5/29/06 8:11 AM Page 1 CHAPTER 4 FIXTURES There is much more to fixtures than meets the eye. Fixtures are a part of the final phase of plumbing. When you are planning a plumbing system,

More information

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products. Wastewater Guidelines for Sizing Features These guidelines cover the steps which need to be taken to accurately select the correct sewage pump and applicable systems to use in sewage ejectors. Work through

More information

Structural Guidelines. Food Service Establishments. Retail Food Stores

Structural Guidelines. Food Service Establishments. Retail Food Stores Structural Guidelines for Food Service Establishments and Retail Food Stores Jefferson County Department of Health Food & Lodging Protection Division 1 Before construction or remodeling of a food service

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information