FLOOR CONSOLE / UNDER CEILING DUAL type
|
|
- Laurel Gwendoline Gray
- 5 years ago
- Views:
Transcription
1 SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM... CIRCUIT DIAGRAM... PCB CIRCUIT DIAGRAM... 7 ERROR DISPLAY... DISASSEMBLY ILLUSTRATION (Indoor Unit)... DISASSEMBLY ILLUSTRATION (Outdoor Unit)... 0 PARTS LIST (Indoor Unit)... PARTS LIST (Outdoor Unit)... 6 ACCESSORIES... 7
2 SPECIFICATIONS TYPE Cool and Heat INDOOR UNIT OUTDOOR UNIT COOLING CAPACITY ABU8RULX AOU8RLX 7,800 / 7,800 BTU/h ABURULX AOURLX,00 /,00 BTU/h HEATING CAPACITY,00 /,00 BTU/h,00 /,00 BTU/h ELECTRICAL DATA POWER SOURCE 0 V / 08 V FREQUENCY 60 Hz RUNNING CURRENT (Cool) 7. A / 7.9 A 9.8 A / 0.9 A RUNNING CURRENT (Heat) INPUT WATTS (Cool) 9.8 A / 0.9 A.6 kw /.6 kw 0. A /. A. kw /. kw INPUT WATTS (Heat) E.E.R. (Cool). kw /. kw.9 /.9 kw/kw. kw /. kw.89 /.89 kw/kw E.E.R. (Heat) MOISTURE REMOVAL ( /hr).80 /.80 kw/kw. L/hr.0 /.0 kw/kw. L/hr AIR CIRCULATION-Hi (m /hr) 780 m /hr 880 m /hr COMPRESSOR TYPE DISCRIMINATION REFRIGERANT R0A Hermetic type, poles, Inverter, Twin Rotary TNB0FPBM9 lb oz (,900 g) FAN MOTOR POWER SOURCE DISCRIMINATION INDOOR UNIT HIGH-SPEED ( Cool / Heat ) MED-SPEED LOW-SPEED OUTDOOR UNIT DISCRIMINATION ( Cool / Heat ) HIGH- SPEED 0 V MFA-PPT MFA-PPT,060 /,060 r.p.m.,80 /,00 r.p.m. 890 / 890 r.p.m.,000 /,000 r.p.m. 770 / 770 r.p.m. 900 / 900 r.p.m. MFE-ROM MFE-ROM 780 / 780 r.p.m. 80 / 900 r.p.m. DIMENSIONS INDOOR UNIT OUTDOOR UNIT HxWxD HxWxD 7-7/8" x 9-/8" x -7/8" inch (99 x 990 x 6 mm) -/" x -/" x " inch (80 x 900 x 0 mm) WEIGHT INDOOR UNIT OUTDOOR UNIT Gross / Net Gross / Net 7 kg / 8 kg 70 kg / 6 kg REFRIGERANT CHARGE (R0A) Pipe Length FULL CHARGE AMOUNT 9 ft. ( m) lb oz (,900 g) 66 ft. (0 m) lb 7oz (,000 g) 98 ft. (0 m) lb oz (,00 g) ft. (0 m) lb oz (,00 g) 6 ft. (0 m) lb oz (,600 g) ADDITIONAL REFRIGERANT 0.oz / ft. (0 g/ m) lb oz (,900 g) lb 0oz (,00 g) lb 8oz (,00 g) 6 lb 6oz (,900 g) 7 lb oz (,00 g) 0. oz / ft. (0 g/m)
3 OUTLINE AND DIMENSIONS INDOOR UNIT Models : ABU8RULX, ABURULX Unit : inch (mm) -7/8" (6) 9-/8" (990) 7-7/8" (99) (rear view) " (900) 9-/" (00) 0-7/8" (0) -/6" ( 00) -/" (0) -/" (70) 7-7/" (99) 6-7/8" (7) 7-7/8" (00)
4 OUTDOOR UNIT Models: AOU8RLX, AOURLX Unit : inch (mm) -/" (900) "(77) -/" () " (0) /" () -/" (80) 7/8" () 7-/8" (0) /8" (9) -/" (00) -/8" (60) Air Flow -/8" (70) -7/8" (99) 7-/" (96) -/" (7) 6-/" (70) 00..8
5 REFRIGERANT SYSTEM DIAGRAM Models : ABU8RCLX / AOU8RLX OUTDOOR UNIT INDOOR UNIT Pressure Check Valve Refrigerant Pipe.7mm (/") High Pressure Switch Charging Valve Condenser Muffler -way Valve Evaporator Accumulator Compressor Expansion Valve Refrigerant Pipe 6.mm (/") Strainer Strainer Charging Valve Models : ABURULX / AOURLX OUTDOOR UNIT INDOOR UNIT Pressure Check Valve Refrigerant Pipe.88mm (/8") High Pressure Switch Charging Valve Condenser Muffler -way Valve Evaporator Accumulator Compressor Expansion Valve Refrigerant Pipe 9.mm (/8") Strainer Strainer Charging Valve : COOL : HEAT 00..8
6 CIRCUIT DIAGRAM Models : ABU8RULX, ABURULX ROOM TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR INDICATOR PCB ASSY FAN MOTOR CN0 FM GREEN / YELLOW Use T.A-0V Fuse on F BROWN RED ORANGE YELLOW BLUE PURPLE GRAY RED PINK PURPLE BLUE GRAY GRAY CN RED BROWN RED ORANGE YELLOW BROWN RED ORANGE YELLOW 6 CN CN7 CN CN7 CN8 CONTROLLER PCB ASSY CN CN0 CN FAN MOTOR CAPACITOR M M STEP MOTOR (UP/DOWN) STEP MOTOR ( LEFT / RIGHT ) GREEN L N POWER SUPPLY PCB G RED TERMINAL 00..8
7 Models : AOU8RLX, AOURLX COMPRESSOR CHOKE COIL U PIPE TEMPERATURE THERMISTOR DISCHARG TEMPERATURE THERMISTOR BROWN EMI FILTER CONNECTOR T RED RED V W ACTIVE FILTER MODULE TERMINAL L L + - BROWN RED ORANGE YELLOW 6 P N YELLOW BLUE EMI FILTER T RED BROWN U W0 V W0 W W0 W W W6 W7 W0 W CN BLUE BROWN CN CN CN CN6 CN CN07 FUSE F T A-0V CN7 CN80 CN7 CN W00 RED RED CN0 CONTROLLER PCB ASSY FUSE F T.A-0V RED YELLOW BLUE 6 RED BROWN BLUE ORANGE YELLOW 6 OUTDOOR TEMPERATURE THERMISTOR COMPRESSOR TEMPERATURE THERMISTOR HEAT SINK TEMPERATURE THERMISTOR WV FM EV HIGH PRESSURE SWITCH SOLENOID COIL FANMOTOR EXPANSION VALVE COIL TM0 BROWN RED CN W9 W8 POWER SUPPLY PCB ASSY TM0 W W6 W7 W W GREEN RED G EARTH (N) L N G EARTH
8 INDOOR PCB CIRCUIT DIAGRAM Models : ABU8RULX ABURULX CONTROLLER PCB ASSY ABU8RULX : K0AL-00PHSE-C ABURULX : K0AL-00SHSE-C 7
9 OUTDOOR PCB CIRCUIT DIAGRAM Models : AOU8RLX AOURLX POWER SUPPLY PCB ASSY K0BA-000HUE-P INVERTER ASSEMBLY AOU8RLX : EZ-00GHUE AOURLX : EZ-00FHUE CONTROLLER PCB ASSY AOU8RLX : K0AW-00HUE-C AOURLX : K0AW-00HUE-C 8
10 00..8 Models : AOU8RLX, AOURLX CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AOU8RLX : K0AW-00HUE-C AOURLX : K0AW-00HUE-C 9 600/0V x
11 Models : AOU8RLX, AOURLX POWER SUPPLY PCB ASSEMBLY K0BA-000HUE-P0 * AOU8RLX, AOURLX : W and W AOU6RLX, AOURLX : W and W POWER SOURCE 0V 60Hz * * W or W W or W B B VA0 70V <TNR> VA0 70V <TNR> C0. <LE> SA00 RA-0M L RCH70-0PF07 C0 0.0 <YE> C0 0.0 <YE> C06. <LE> TM00 L N0000KD7C C07. <LE> TO INDOOR UNIT W6 W7 B B CT CT-B EARTH W GREEN B V D60 DAN7U + AC VOLT OUT W8 W9 B B R60.0K </0W> (%) C60 0/6V <PJ> L RCH70-0PF07 C. <LE> C 0.0 <YE> C 0.0 <YE> VR BK R6.7K </0W> (%) R68 K </0W> C6 0. <F> C6 0. <F> V TM0 TM0 CN BB-XASK--A CT OUT
12 ERROR CONTENTS (Indoor unit) OERATION TIMER SWING SWING OPERATION lamp (Red) TIMER lamp (Green) SWING lamp (Orange) SWING lamp (Orange) MANUALAUTO Operation can be checked by lighting and flashing of the display section OPERATION,, and TIMER lamps. Perform judgment in accordance with the following. TEST RUNNING When the air conditioner is run by pressing the remote control unit test run button, the OPERATION and TIMER lamps flash slowly at the same time. ERROR The OPERATION, TIMER, and SWING lamps operate as follows (Table) according to the error contents. Error contents Error display OPERATION TIMER SWING (RED) (GREEN) (ORANGE) Indoor unit circuit board error Indoor unit room temperature sensor wire opened Indoor unit room temperature sensor wire short circuited Indoor unit piping sensor wire opened Indoor unit piping sensor short circuited Indoor unit fan error Outdoor unit circuit board error Miswiring between outdoor unit and indoor unit times times times times 6 times times times Outdoor unit discharge temperature sensor error Outdoor unit piping sensor error Outdoor unit outdoor temperature sensor error times times times : Fast flashing : Slow flashing : Off
13 ERROR CONTENTS (outdoor unit). Make a TEST RUN in accordance with the installation instruction sheet for the indoor unit.. OUTDOOR UNIT LEDS When a malfunction occurs in the outdoor unit, the LED on the circuit board lights to indicate the error. Refer to the following table for the description of each error according to the LED. LED Error contents. When the product is operating: Press the PUMP DOWN switch on the outdoor unit. The LED on the outdoor unit circuit board lights, and operation stops. At this point, recovery has not been completed, so do not close the two- and three-way valves. The pump down operation (cooling operation) begins after three minutes. Close the three-way valve (liquid) after operation starts. flash flash flash flash 7 flash 8 flash 9 flash flash flash flash flash 6 flash lighting Communication error (Indoor unit - Outdoor unit) Discharg pipe temperature sensor Outdoor heat exchanger temperature sensor Outdoor temperature sensor Compressor temperature sensor Heat sink temperature sensor Pressure switch abnormal IPM error Compressor rotor position cannot detect Compressor cannot operate Outdoor fan abnormal (upper fan) Outdoor fan abnormal (lower fan) No error After - minutes, operation stops. Close the threeway valve (gas) within one minute after operations stops. The LED will go out three minutes after it stops. Disconnect the power supply after confirming that the LED has gone out. *When the pump down operation is repeated, temporarily disconnect the power supply after opening the closed valves (both liquid and gas). Reconnect the power supply after - minutes and perform the pump down operation. *When the start of the operation after pump down operation has been completed, temporarily disconnect the power supply after opening the closed valves (both liquid and gas). Reconnect the power supply after - minutes and be sure to perform a test operation for cooling. -way valve (Liquid) SPECIAL INSTALLATION SETTING PUMP DOWN (Refrigerant collecting operation) Perform the following procedures to collect the refrigerant when moving the indoor unit or the outdoor unit.. When the product is stopped: -way valve (Gas) PUMP DOWN SW (SW) Press the PUMP DOWN switch on the outdoor unit. (The LED on the outdoor unit circuit board lights.) The pump down operation (cooling operation) begins right away. After oparation starts, close the three-way valve (liquid). After - minutes, operation stops. Close the threeway valve (gas) within one minute after operations stops. The LED will go out three minutes after it stops.disconnect the power supply after confirming that the LED has gone out. DANGER This part (Choke coil) generates high voltages. Never touch this part
14 DISASSEMBLY ASSEMBLY Models : ABU8RULX, ABURULX
15
16
17 INDOOR UNIT
18 OPTIONAL PARTS
19
20
21 Models : AOU8RLX AOURLX
22 Models : AOU8RLX AOURLX
23 Models : AOU8RLX AOURLX
24 Models : AOU8RLX AOURLX
25 PARTS LIST INDOOR UNIT Ref. No. Description ABU8RULX Part No. ABURULX Ord. Q'ty 8 Air Filter Capacitor (Fan Motor) Sirocco Fan Assy Rubber (Vibration-proof) Cap, Plastic Louver Base Assy Casing, Plastic Kit (Dew Proof Plate) Motor Fixing Table Assy Drain Hose Assy Kit (Separate Wall-A) Evaporator Assy KB Drain Pan Assy (Kit) Fan Motor Assy-IN Hanger Bracket-L Hanger Bracket-R Thermistor Spring-A Clamp No Clamp SKB Clamp SKB-M Control Box Thermistor Assy-Room Thermistor Assy-Pipe Controller PCB Assy (K0AL-00PHSE-C) (K0AL-00SHSE-C) 0 Remote Control Unit Flap (Upper)-F Flap (Lower) Motor Fixture Bushing Bushing-B, Plastic Bushing-C, Plastic Special Screw Special Screw Locking Spacer, KGLS-S Indicator PCB Assy Motor Rod Louver Link Insulation (Panel)-A Insulation (Panel)-B Insulation (Flap Base) Arm Bracket Separate Wall-B (Kit) Grille Support Filter Bracket Grill-F When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.
26 INDOOR UNIT (Continued) Ref. No. Description ABU8RULX Part No. ABURULX Ord. Q'ty 00 Protect Cover Support Stay Louver Shaft Louver Stopper Louver Rod Cosmetic Panel-R Cosmetic Panel-L Control Box Cover Flap Base Louver Link Cover Flap Link-Upper (Step Motor-V) Flap Link-Lower (Step Motor-V) Motor Rod-A (Step Motor-V) Catch TL Base Bracket (Reinforcement Metal) Top Cover Protector, Metal (Fan Motor) Cord Bushing KR Locking Spacer-B Thermistor Holder Pipe Bolt Motor Base Holder (Guide Rail) Distributor Assy Remote Control Unit Holder Casing Cover Drain Cap Panel Bypass Pipe Assy Terminal 7P Fuse BET.A - 0V Arm Power Supply PCB Assy (K0AL-00PHSE-PO) (K0AL-00PHSE-PO) 876- Step Motor-H Step Motor-V EMI Filter When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.
27 OUTDOOR UNIT Ref. No. Description AOU8RLX Part No. AOURLX Top Panel Sub Assy Front Panel Fan Guard Grip Side Service Panel Sub Assy Right Panel Emblem Rear Propeller Fan Assy Motor, Induction Condenser-A Assy Ord. Q'ty Strainer Assy Separate Wall Assy Cap Foot Base Assy Way Valve Assy (/8") Way Valve Assy (/") Way Valve Assy (/8") Way Valve Assy (/") Check Joint Assy Compressor Assy Way Valve Solenoid Pressure Switch Inlet Pipe Cond A Assy Inlet Pipe Cond B Assy Outlet Pipe Cond A Assy Expansion Valve Assy Coil (Expansion Valve) Distributor Discharge Pipe A Assy Terminal P Terminal P ACTPM Holder Thermo Inverter PCB Assy Power PCB Assy Motor Bracket Sub Assy Choke Coil Fuse.A-0V Thermistor (Outdoor Temp.) Heat Exchanger Thermistor Thermistor (Discharge) Compressor Thermistor Thermistor Heatsink Thermistor Transformer Varistor Arrester Relay Relay Switch Push Switch Slide Drain Pipe Assy Drain Cap Coil Choke When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.
28 STANDARD ACCESSORIES The following installation parts are furnished. Use them as required. INDOOR UNIT ACCESSORIES Name and Shape Q'ty Application Part No. Cosmetic Panel-L Cosmetic Panel-R 980 Tapping screw ( x 0) Installation template For positioning the indoor unit. For under ceiling type Hanger bracket (left) For suspending the indoor unit from ceiling Hanger bracket- (right) Anchor bolt (M) Special nut Spring washer Wall bracket For suspending the indoor unit on the wall Tapping screw ( x 0) 6 For fixing the wall bracket Coupler heat insulator (large) For indoor side pipe joint. (Large pipe) Coupler heat insulator (small) For indoor side pipe joint. (Small pipe) 0980 Nylon fastener For fixing the drain hose Drain hose Insulation (drain hose) Adhesive type 70 x VT wire For fixing the drain hose L 80 mm
29 REMOTE CONTROL UNIT Name and Shape Q'ty Application Part No. Remote control unit Use for air conditioner operation (AR-JW) Battery (penlight) For remote control unit Remote control unit holder Hold the remote control unit 9060 Tapping screw ( x ) For remote control unit holder installation Wired remote controller unit is also available : UTB-UUB (Parts No ) OUTDOOR UNIT ACCESSORIES Name and Shape Q'ty Application Part No. Drain pipe Drain cap For outdoor unit drain piping work (May not be supplied, depending on the model)
30 0G98
FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...
More informationCEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM
More informationSPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB
More informationCASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.
SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationDUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-8CA RCW-8HA RO-8CB RO-8HB C O N T E N T S SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................
More informationWALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )
SPLIT T YPE ROOM AIR CONDITIONER WALL MOUNTE type Models Outdoor Unit Serial No. Starting with T000001 ( Compressor Recipro type ) Indoor unit ASU18C1 ASU18R1 ASU24C1 ASU24R1 ASU30C1 Outdoor unit AOU18C1
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARY0ELA AOY0EPBL CONTENTS SPECIFICATIONS.............................. OUTLINE AND DIMENSIONS...................... CIRCUIT DIAGRAM............................
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFW AOURLXFW CONTENTS SPECIFICATIONS.................... DIMENSIONS........................ REFRIGERANT SYSTEM
More informationASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT
WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFWH AOURLXFWH CONTENTS SPECIFICATIONS.................... DIMENSIONS........................
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC ARG30ALC ARG30RLC ARY30ALC ARY30RLC ART30ALC ART30RLC AOG25ANBL AOG25RNBL
More informationAUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit AUXG8LRL AUXGLRL UTG-UKYA-W Outdoor unit AOYG8LCA AOYGLCA CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUG25ALC-W AUG25ALQ-W AUG25RLC-W AUG30ALC-W AUG30ALQ-W AUG30RLC-W AOG25AZCL AOG25AZQL AOG25RZCL AOG30ABML AOG30ABSL AOG30RBML
More informationC E IL IN G W A L L SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE ROOM AIR CONDITIONER C E IL IN G W A L L t y pe Models Indoor unit Outdoor unit AWY24LBAJ AOY24LMAL AOY30LMAL CONTENTS SPECIFICATIONS................................ 1 OUTLINE AND DIMENSIONS..........................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationSERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS
SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationEXPLODED VIEWS & PARTS LISTS
542 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Rev 8/08 # This parts
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationTAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT
More informationRepair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:
Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606
MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50HZ units Mile High Equipment 11100 East 45th Ave Denver, Colorado 80239 Print Date 03/03 * This parts list contains
More informationКондиционеры Mitsubishi Heavy
Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK28HD, SRK40HD INDOOR UNIT Models SRK28HD, SRK40HD OUTDOOR UNIT Model SRC28HD REMOTE CONTROLLER Model SRC40HD GENERAL
More informationSERVICE Manual FREE JOINT MULTI AIR CONDITIONER
FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4
More informationGlobal-Tek (Singapore) Pte Ltd
Global-Tek (Singapore) Pte Ltd Door Type G-TEK G-TEK WWW.GLOBAL-TEK.COM.SG 1 P a g e Door Type, CONTENTS Wash and Rinse Arm Assembly....... 3-4 Booster Heater... 5-6 Wash Chamber.. 7-8 Door Lift Assembly...9-10
More informationEXPLODED VIEWS & PARTS LISTS
561 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationCABINET PARTS For Model: KSSS48QJX00 (Stainless Steel)
CABINET PARTS 48" BUILT IN REFRIGERATOR 10 02 Litho In U.S.A. (mek) 1 Part No. 1 LITERATURE PARTS LIT2209249 Use & Care Guide LIT2006651 Energy Label LIT2006748 Service & Wiring Sheet LIT628370 Modular
More informationINVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)
TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationAmendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz
More informationInstallation and Homeowners Guide
Installation and Homeowners Guide Underscore Bathroom Heater S450 S450 K-77315T-G-MZ/K-77283T-G-MZ KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD, JING'AN DISTRICT, SHANGHAI, PRC POST CODE:
More informationParts and Service Manual
Section II Parts and Service Manual (70241A) CLARKE TECHNOLOGY Operator's Manual - MINI MAX Page -29- Frame and Front Cover Assembly Drawing 2/01 Page -30- CLARKE TECHNOLOGY Operator's Manual -MINI MAX
More informationCU1526, CU2026, CU3030 Service Parts
This is the illustrated list of service parts for all models of the CU, CU0 and CU00 self contained ice machines. These machines were manufactured in several voltages, which is designated by a numeric
More informationKSSS42QDW05, KSSS42QDX05
CABINET PARTS 42" BUILT IN REFRIGERATOR 4 97 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 Cabinet (Not A Serviceable Part) 3 2005004 Grommet, Tube Crossover 4 1112023 Roller, Front & Rear (4) 5 Support,
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product
More informationParts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationRoom Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02
Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE
More information6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)
6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationWALL MOUNTED TYPE ROOM AIR-CONDITIONER
TECHNICAL MANUAL & PARTS LIST DRAFT WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK50HE-S, SRK56HE-S (Split system, air cooled cooling only type) SRK50CE-S, SRK56CE-S
More informationCU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,
Order No. MAC0605029C2 Air Conditioner CS-F18DTE5 CU-B34DBE5 CS-F18DTE5 CU-B34DBE8 CS-F24DTE5 CU-B43DBE8 CS-F28DTE5 CU-B50DBE8 Please file and use this manual together with the service manual for Model
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationImage Key Part Number Description Substitution Qty.
Model Number: BOM/Serial #: Graphic Title: XRSR465BW PXRSR465BW0 SUPPLEMENTAL INFORMATION Image Key Part Number Description Substitution Qty. 1 1 67002385 HARNESS-CONTROL 1 1 1 67002384 HARNESS, ICE MAKER
More informationParts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-1100MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71392 Issued: 12-12-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationRoom Air Conditioner Service and Parts Manual
Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2
More informationDuctless Split Air Conditioner
Ductless Split Air Conditioner Service Manual Indoor AW09ESVHA AWESVHA AW8ESVHA AWESVHA Outdoor U09ESVHA UESVHA U8ESVHA UESVHA Design may vary by model number. Please read this manual before using the
More informationCMS1402 SERVICE PARTS
This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU9RLQ AOU12RLQ AOU18CL AOU18RL
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU9RLQ ASURLQ ASU8CL ASU8RL AOU9RLQ AOURLQ AOU8CL AOU8RL R40A CONTENTS. SPECIFICATION ASU9/RLQ,
More informationSingle Zone Air Conditioner SVC MANUAL (Exploded View)
Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10
More informationSERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications
SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT SERVICE Manual SYSTEM AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Set Up the
More informationSERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.
SERVICE MANUAL Indoor unit Outdoor unit 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* INDEX PART1 GENERAL INFORMATION PART2 ELECTRICAL DIAGRAM PART3 TROUBLE
More informationHID312, HID525 and HID540 Service Parts
This is the illustrated parts list for Scotsman ice maker-dispenser models HID, HID and HID0. They were manufactured in voltages and there is also a separate wall mount model. Please confirm the complete
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationTECHNICAL & SERVICE MANUAL. Ceiling Concealed
STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A
More informationDuctless Split Air Conditioner
Ductless Split Air Conditioner Service Manual Indoor HSU09VHG(DB)-W HSUVHG(DB)-W HSU8VHH(DB)-W HSUVHG(DB)-W Outdoor HSU09VHG(DB)-G HSUVHG(DB)-G HSU8VHH(DB)-G HSUVHG(DB)-G Design may vary by model number.
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081307-01 Rev 3/06 * This parts list contains
More informationCABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)
CABINET PARTS 42" BUILT IN REFRIGERATOR 1 08 Litho In U.S.A. (mat) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10151251 Use & Care Guide W10164079 Energy Guide W10159831 Service & Wiring Sheet
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationSERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC
Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.
More informationMDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5
This is the list of service parts for the MDT2C12A-1A and MDT2C12A-1B ice maker dispensers. The B series model began in late 2014. It has a number of electrical differences from the prior model. Always
More informationECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL
ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution
More informationP MODEL AIR CONDITIONER
CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS R-94 P MODEL AIR CONDITIONER JOB AID Part No. 8178039 FORWARD This Whirlpool Job Aid, P Model Air Conditioner (Part No. 8178039), provides the technician
More informationTABLE OF CONTENTS. Air Conditioner
Order No. MAC0804027A2 Air Conditioner CS-E9GFEW-2 CU-E9GFE-2 CS-E12GFEW-2 CU-E12GFE-2 CS-E18GFEW-2 CU-E18GFE-2 CU-2E15GBE CU-3E18EBE CU-3E23CBPG CU-4E27CBPG Please file and use this manual together with
More informationCME650 SERVICE PARTS
This section contains the parts illustrations and parts lists for the CME650. CM650 ice machines are manufactured in both 60 cycle and 50 cycle. When ordering electrical parts, be certain to match the
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...
More information4. Disassembly and Reassembly
4. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1 Indoor Unit 4-1-1 MH FPEA /MH VP2-1 Front Panel 1) Stop the air conditioner
More informationSERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305
SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains
More informationMFE400 SERVICE PARTS
This is the parts list for all MFE400 model units. The complete model number must be checked, especially when ordering electrical parts, as this model was manufactured in 0 Hz and 0 Hz versions. Table
More informationProduct Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW
0Hz Heat Pump Inverter Single Phase.kW to 8.0kW turn to the experts Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal capacity are available from.kw through 8.0kW to meet the needs of residential
More informationCHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION
CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION PART NUMBER BY CAPACITY 9/12 15 18/24 30 36/42 48 1 1 FRONT PANEL W/LOUVER 550-373 550-373 550-374 550-374 550-388
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513
TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before
More informationSpare Parts Catalogue MV1006
Spare Parts Catalogue MV1006 1 - UNIT PANELS - AIR COOLED 2 - UNIT PANELS - WATER COOLED 3 - REFRIGERANT SYSTEM - AIR COOLED - UP TO S.N. 00462 4 - REFRIGERANT SYSTEM - AIR COOLED - FROM S.N. 00463 TO
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XHS7 & PNRXS87 + CH7 XHS87 & PNRXS87 + CH87 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS7 (PNRXS87) XHS87 (PNRXS87)
More informationCME1056 Service Parts. Table of Contents
This is the parts list for the CME0 ice machine. The CME0 was manufactured in A, D, E and F series, as well as single phase 0 Hz, single phase 0 Hz, and three phase. The E series change was to side panels
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationSERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications
CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Block Diagrams
More informationRAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E
FILE NO. A0-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Jun.,003 ToMo . EXPLODED VIEWS AND PARTS LIST -. Indoor Unit () 0 0 6 35 5 4 0 5 33 7 08 6 07 9 3 0 3 8 30 39
More informationR22 air-cooled modular chiller 50Hz unit. Content
Content 1.Nomenclature... 2 2.Product Schedule... 2. External Appearance... 4.Features... 4 5.Specification... 6 6.Dimension... 10 7.Refrigeration System Sketch Drawing... 14 8.Wiring Diagrams... 16 9.Electric
More informationSERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1
SERVICE MANUAL Inverter Wall Mounted Single Split MODELS Cooling Only FTKB09AXVJU FTKB12AXVJU FTKB18AXVJU FTKB24AXVJU FTKN09AXVJU FTKN12AXVJU FTKN18AXVJU FTKN24AXVJU Heatpump FTXB09AXVJU FTXB12AXVJU FTXB18AXVJU
More informationGUG-01SL-E GUG-02SL-E GUG-03SL-E
1604876HE5501 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation
More information