1 Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. MITSUBISHI ELECTRIC CORPORATION
2 Contents Safety precautions Specifications Dimensions Wiring diagrams Maintenance procedures Blower Parts Damper Motor Part (All units available) Circuit Board Part Humidifier Parts Heat exchanger for refrigerant Part Solenoid valve and water sencor Part Parts list GUF-50RDH GUF-100RDH
3 Safety precautions Please be sure to read the following safety precautions thoroughly before commencing with the maintenance work, and conduct the inspection and repair of the product in a safe manner. The types and levels of danger that may arise if the product is handled incorrectly are described by using the warning symbols shown below. Warning Electric shock If you must inspect the circuitry while the power is on, do not touch the live parts. (Failure to heed this warning may result in electric shock.) Modification is prohibited Do not modify the unit. (Failure to heed this warning may result in electric shock, fire and/or bodily injury.) Caution for electric shock Prohibited Do not mix anything other than (Use the specified coolant of the same type used in the outdoor unit.) Do not charge any coolant different from the coolant used in the outdoor unit. (Failure to heed this warning may cause the pressure inside the freezing cycle to become abnormally high, leading to bodily injury or other damage.) Prohibited Toxic gas generation Be careful that the coolant (R40C,R410A,R22) does not leak in a flammable environment. Conduct welding operation in an open room. If the coolant gas leaks, open the windows while in operation. Be sure to completely repair the leak. Close the service valve if the repair work is temporarily suspended. (If the coolant gas comes into contact with flames such as open fire, sparks and a heater, it may generate toxic gas.) Be sure to follow this instruction. Incorrect handling of the product may result in serious injury or death. Turn off the power supply Be sure to shut off the breaker before disassembling the unit for repair. (Failure to heed this warning may result in electric shock.) Use proper parts and tools For repair, be sure to use the parts listed in the service parts list of the applicable unit model and use the proper tools. (Failure to heed this warning may result in electric shock, fire and/or bodily injury.) Proper electric work Use the electric wires designated for electric work, and conduct electric work in accordance with the "Electric Installation Engineering Standard," the "Indoor Wiring Regulations," and the Installation Work Guide. (Incomplete connection or wiring installation may result in electric shock and/or fire.) Be sure to follow this instruction. Be sure to follow this instruction. Be sure to follow this instruction. Replace damaged and/or degraded parts Be sure to replace the power-supply cord and lead wire in the event that they are damaged and/or degraded. (Failure to heed this warning may result in electric shock and/or fire.) Check insulation Be sure to measure the insulation resistance once the repair work is complete, and turn on the power supply after verifying that an insulation resistance of at least 1MΩ is obtained. Be sure to follow this instruction. (If an insulation problem exists, it may result in electric shock.) Be sure to follow this instruction. 3
4 Caution Caution for bodily injury Do not conduct any work at a location where you do not have a sure footing. (Failure to heed this caution may result in a fall.) Wear gloves when conducting work. (Failure to heed this caution may result in injury to your hands from sharp metal or other edges.) Incorrect handling of the product may result in serious injury or damage to properties including buildings and equipment. Prohibited Be sure to follow this instruction. Prevent water leakage Before removing any of the water-related parts, completely drain the residual water from the piping. After the repair is complete, be sure to check the drainage of the indoor unit and that no water leaks from any of the piping connections. (Water leakage may cause buildings to soil, leading to secondary failure of other parts.) Be sure to follow this instruction. Request during repair Inspect the grounding, and repair it if incomplete. Make sure that the product operates correctly upon completion of repair. Clean the product as well as the surrounding area, and then notify the customer of the completion of repair. 1. Specifications Model name Power supply (V) Frequency (Hz) Current (A) Power consumption (W) Air volume m 3 /h L/S External air load heat processing capability (kw) Cooling capability Heating capability Humidifying volume Noise (db) Weight (kg) Equivalent indoor unit capability GUF-50RDH3 GUF-100RDH3 Singlephase , (1.66) (3.49) 6.42 (2.25) (4.0) P32 P63 The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic chamber. The noise at the air outlets (at a 45 angle, 1.5 meters in front) is about 5-6 db (A) higher than the values given in the table. The above values apply during Lossnay ventilation when the fan speed is set to high speed. * Capacity in ( ) is heat recovery capacity by Lossnay core. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling: Indoor: 2 C DB/19.5 C WB Outdoor: 35 C DB/24 C WB Heating: Indoor: 21 C DB/14.6 C WB Outdoor: C DB/6 C WB 4
5 2. Dimensions GUF-50RDH3,GUF-100RDH3 Air exhaust fan N Location at which the duct direction can be changed Damper plate Ceiling suspension fixture (4 places length hole for GUF-50RDH3) D Ceiling suspension fixture (4 places length hole for GUF-100RDH3) EA (Exhaust air) RA (Return air) Air supply fan L M K OA (Outdoor air) Lossnay core Air filter High efficiency filter Fan Maintenance space B More than to 250 Maintenance cover Can install upper area of ceiling suspension fixture (GUF-100RDH3) N Lossnay core T Inspection opening F E 9 A 9 (N) 9 S (Water intake) 60 Inspection opening Control box High efficiency filter (Optional part) Heat exchanger øh øj SA (Supply air) Solenoid valve unit with pressure regulator* Solenoid valve Heat exchange unit Humidifying element Maintenance space Humidifying element* 100 Power cable installation port C G 20 Ceiling suspension fixture Location at which the duct direction can be changed Air filters Q R 30 P (Discharge hole) Water intake strainer with check valve (PT1/2 External thread) Maintenance cover Gas pipe (U) Liquid pipe (V) Drain discharge hole (VP25 connection) Model External Ceiling suspension Duct connection Duct pitch Humidification Inspection Flare dimension fixture pitch flange opening A B C D E F Nominal G H J K L M N P Q R S T diameter U V GUF-50RDH GUF-100RDH ø12. ø15.88 ø6.35 ø9.52 Unit (mm) 5
6 3. Wiring diagrams GUF-50RDH3,GUF-100RDH3 6
7 4. Maintenance procedures 4-1 Blower Parts 1Remove the cover fixing special screw. 2Pull back the hinged clip. 2Open the door and lift off of the hinge brackets. Maintenance cover Special screw Hinge 3Remove Filters from the unit. 4Remove Lossnay cores from the unit. Lossnay core Filter 5Remove screw from the core-guide,remove coreguide. Core Guide
8 6Remove separator from the blower portion. Remove connections motor lead wire. Separator 8Remove screws from the motor base. Motor Base Motor 9Remove the pre-assembled blower. Pre-assembled Blower 8
9 4-2 Damper Motor Part (All units available) 1Remove (2) screws out from the damper motor cover. Damper Motor Cover 2Take the damper motor out of the cover. Damper Motor 4-3 Circuit Board Part 1Remove the 4 screws from the control cover. Screw Control Cover 2Remove the 3 screws from capacitors. (2 screws for the GUF-50RDH3) Capacitors 9
10 3Remove all harnesses connected to the circuit board. 4Take the circuit board out. Circuit Board 4-4 Humidifier Parts The photograph shows GUF-100RDH3. 1Remove the screws to remove the humidifier cover. Screw Humidifier cover 2Remove the Humidifier cover (Inner lid). Humidifier cover (Inner lid) 10
11 3Remove the water supply tube from the humidifying element. Water supply tube 4Holding the hose bands indicated by [1] to [6] with your fingers, remove the water supply tubes. Referring to the procedure entitled removing the humidifying elements below, remove the water supply tube at the rear while taking out the front humidifying element. Caution: To remove the water supply tube, hold and slide the hose bands and remove the water supply tube. Do not remove the water supply tube from the solenoid valve unit with a pressure regulator. When removing the water supply tube, be sure that water is collected on the drain tray inside the main unit. Water supply tube Solenoid valve unit with pressure regulator [3] [2] [1] Hose band [4] [5] [6] Humidifying element Water supply tube 5Remove the humidfying elements. Humidifying element 11
12 4-5 Heat exchanger for refrigerant Part 1Remove the 11 screws to remove cover (L) and cover (S). (9 screws for the GUF-50RDH3) Cover (L) Screw Cover (S) 2Remove connections of themistor lead wire and lenear expansion valve lead wire. 3Remove the 2 screws to remove the Fixture. 4Remove the heat exchanger from the unit. Screw Fixture Heat exchanger Connection Humidifying element 5Remove the 2 screws to remove the Fix plate. Fix plate 2 screws 12
13 Water sensor and solenoid valve installation positions 4-6 Solenoid valve and water sencor Part 1Remove connections of solenoid valve lead wire and water sencor lead wire. 2Remove pipes connected to the solenoid valve. Connection Solenoid Valve Connection for water sencor cover (solenoid valve) 3Remove the 2 screws to remove the cover (solenoid valve). 4Remove the 2 screws to remove the solenoid valve. Solenoid valve 13
14 5Remove a screw to remove the water sencor. Installed condition of GUF-100RDH3 Fixing position of water sensor plate (GUF-50RDH3) Water sensor plate Fixing position of water sensor plate (GUF-100RDH3) 6The hole at the fixing position of the water sensor plate (GUF-50RDH3) is no longer visible. Installed condition of GUF-50RDH3 14
15 5. Parts list Please note the following when using the parts list. 1. When ordering parts, always indicate the part number, part name, and number of parts required. 2. Parts are not always available, and it may take time for you to receive them. 3. There may be specification improvements or prices changes. 4. Specifications and prices are as of July Parts marked are critical for safety. To maintain safety and performance, always replace these parts with the parts prescribed. 6. The numbers that are circled in the exploded view are the same as the reference number for the part being indicated. Description of screw abbreviations Screw 4 16 Screw diameter Length Abbreviation PC screw PRC screw PP screw SW PP screw PPT screw PCT screw PTT screw PT screw SET screw SQ SET screw P SET screw PMT screw HS SET screw P R W screw P C W screw P R C W screw R W screw PW PP screw SW-PW PP screw Description Cross recess flat head machine screw Cross recess oval head machine screw Cross recess pan head machine screw Cross recess pan head screw with spring washer Cross recess tapping screw Cross recess flat head tapping screw Cross recess truss head tapping screw Cross recess truss head machine screw Slotted head stop screw Square head stop screw Pan head stop screw Primer truss head screw Hexagon head stop screw Cross recess round wood screw Cross recess flat head wood screw Cross recess round and flat wood screw Slotted round wood screw Cross recess pan head screw with small washer Cross recess pan head machine screw with spring washer and flat washer 15
16 11
17
18 11
19 Air Supply fan assembly Air Exhaust fan assembly
20 22
21 For air supply (SA) For air exhaust (EA) OA RA
22 22
23
24 22
25 Air Supply fan assembly Air Exhaust fan assembly
26 21
27 For air supply (SA) For air exhaust (EA) OA RA
28 Printed in Japan in July, <MEE>
Installation Instructions
0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation
More informationInstallation/Instruction Manual
1510876HC8902 Pressurized ventilators (for device cooling) Model Blade diameter (cm) Indoor or outdoor EF-20UYS-UL EF-25UAS-UL EF-30UBS-UL 20 25 30 Indoor Installation/Instruction Manual For customers
More information250mm dia straight pipe length SP4 SP3. Air volume
MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material
More informationWARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English
English LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) MODEL VL-220CZGV-E Instruction Manual For user Contents 1. Safety Precautions 1-2 2. Features 2 3. Preparations Before Use 3 4. Names and Functions
More informationGUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3
Fresh Master ENGLISH Models: GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3 Operating Instructions (For the user) GUF-50RDH3 shown above. Humidifier function not available on GUF-50RD3 and GUF-100RD3. Contents
More informationTCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English
AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the
More informationHC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions
1509876HC8301 Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions Energy Recovery Ventilator MODELS: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions (For the user)
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)
27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)
LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationUser s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS
www.windsterhood.com User s Manual UNDER CABINET SERIES WS-208LF30SS WS-208LF36SS NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS
More informationFresh Master. Installation Instructions (For use by dealer/contractor) GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3. Models:
Fresh Master Models: GUF-0RDH GUF-0RD GUF-00RDH GUF-00RD Installation Instructions (For use by dealer/contractor) GUF-0RDH shown above. Contents. Safety precautions... -. Accessories.... Outline drawings....
More informationService Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.
Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers. Energy Recovery Ventilator (sold in Europe market) Model No. Panasonic
More informationGUF-RD3 GUF-RDH3. OA Processing unit CONTENTS. OA Processing unit R410A
OTETS GUF-RD3 GUF-RDH3. Specifications -6 2. Sound evels -7 2. oise levels -7 2.2 Fan characteristics curves -8 3. External Dimension -9 4. Wiring Diagrams - - . Specifications Item Power supply urrent
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationAUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET
AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH
More informationINSTALLATION MANUAL AIR CONDITIONER
ENGLISH FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national
More informationTECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER
Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)
More informationOperating Instructions Air Conditioner
Operating Instructions Air Conditioner Model No. OUTDOOR UNIT Single Split (Single-phase) Type PZ2 U-100PZ2R5 U-125PZ2R5 U-140PZ2R5 Single Split (3-phase) Type PZ2 U-100PZ2R8 U-125PZ2R8 U-140PZ2R8 Connectable
More informationGUG-01SL-E GUG-02SL-E GUG-03SL-E
1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E
More information4. Disassembly and Reassembly
4. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1 Indoor Unit 4-1-1 MH FPEA /MH VP2-1 Front Panel 1) Stop the air conditioner
More informationGUG-01SL-E GUG-02SL-E GUG-03SL-E
1604876HE5501 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation
More informationUser s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.
www.windsterhood.com User s Manual UNDER CABINET SERIES RA-3030SS RA-3036SS NOTE: This unit was designed for indoor residential use and DUCTED operation only. DO NOT USE OVER A WOOD GRILL OR MOUNT OUTDOOR
More informationSAFETY AND INSTALLATION MANUAL MODEL 8100
SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table
More informationINSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series
INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series PORTUGUÊS ENGLISH ITALIANO ESPAÑOL FRANÇAIS ERV (Energy Recovery Ventilator) DEUTSCH E S F I P D DB98-27512A(3)
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513
TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before
More informationCONTENTS DESCRIPTION UNPACKING DIMENSIONS
INSTALLATION INSTRUCTIONS Ventilating Fan ModelNo.FV-08VRE CONTENTS GENERAL SAFETY INFORMATION DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM INSTALLATION (BETWEEN JOISTS MOUNTING)
More informationSERVICE MANUAL. Air to Air Heat Exchanger. Concealed microcomputer control type VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE
FILE No. A10-021 Air to Air Heat SERVICE MANUAL Concealed microcomputer control type Model name: VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE Contents 1 Features............................................................
More informationVL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)
English Mitsubishi Lossnay Ventilator MODELS VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type) Operating Instructions For Customer Contents Page 1. Safety precautions... 1 2. When using the unit...
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationInstallation Instructions
CNPHP Cased N s Horizontal Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION...
More informationRefrigerant Recovery Machine. Model No Operating Manual
Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be
More informationOwner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger
Air to Air Exchanger Owner s Manual Concealed Microcomputer Control Type l name: M150 M250 M350 M500 M650 M800 M1000 M1500 M2000 For commercial use Owner s Manual English Air to Air Exchanger Owner s Manual
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationHeat Recovery Ventilator with DX Coil 0CED0-01B(Replaces: 0CED0-01A)
0CED0-01B(Replaces: 0CED0-01A) 0CED0-01B(Replaces: 0CED0-01A) 1. External Appearance 2. Models List 3. Model Number Nomenclature 4. Structures 5. Specifications 6. Dimensions 7. Piping Diagrams 8. Wiring
More informationJT-SB116JH-G-NA JT-SB116JH-W-NA
1311875HF4503 Hand dryer MODEL JT-SB116JH-G-NA JT-SB116JH-W-NA Unit color -G (Grey), -W (White) Model Name Display Position. Power voltage display position. INSTRUCTION MANUAL For User Read this manual
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A
TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before
More informationInstallation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents
Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Solenoid Valve Kit For 3WAY VRF System CZ-PXXXHR3 () IMPORTANT! Please Read Before Starting This solenoid Valve kit must be installed by the sales dealer or installer. This information
More informationInstallation Instructions
CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationResidential-Use Lossnay
HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation
More informationOwner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )
Owner s Manual For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12 volts
More informationVentilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH
Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THIS BOOKLET FOR REFERENCE Please use this product according to the installation and operating instructions.
More informationF SERIES SPEAKER SYSTEM
INSTRUCTION MANUAL F SERIES SPEAKER SYSTEM F-160G/F-160W (Low impedance) F-160GM/F-160WM (High impedance) F-160WP (High impedance/outdoor use) F-240G/F-240W (Low impedance) F-240GM/F-240WM (High impedance)
More informationSafety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)
User s Manual TEVHR Contents Safety...1 Control List...2 Components...3 Dimensions...3 Installation...4 Technical Specification...5 Electrical Connection...6 Electrical Scheme...7 Maintenance...10 Control...11
More informationInstallation Instructions Preference Wall Mount Range Hood
Installation Instructions Preference Wall Mount Range Hood For use with models PHW30 and PHW36 Part No. 101745 Rev. D Table of Contents Important Safety Instructions... 1 Important Information About Safety
More informationNON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C
OPERATION MANUAL NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C * Before operating this roaster unit, please read and understand the instructions specified in this manual for proper and safety use.
More informationOriginal instructions. Operation Manual & Cautions
Original instructions Operation Manual & Cautions Thank you for purchasing the Mistresa from Showa Denki. This manual explains the specifications for the [Mistresa units from CRN Series]. Please read the
More information9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.
77 Do not install the condensate assembly if a component is lost or missing. Replace the entire assembly. Failure to follow this warning could result in property damage, serious personal injury, or death.
More information40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT
Carrier International Sdn. Bhd. Malaysia INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT 40LM 120-200 50Hz CONTENTS: Physical Data & Dimension 1-3 Safety Considerations 4 Rigging
More informationGV 8 quart Model BP BATTERY POWERED BACKPACK VACUUM
GV 8 quart Model BP BATTERY POWERED BACKPACK VACUUM Operation Instruction Read all instructions before using this appliance Congratulations on your purchase of the GV 8 Quart Battery Powered Back pack
More informationWhole Home Heat Recovery Ventilation
Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationMODELS: KEH041A42, KEH041A47, KEH041A48. Safety Considerations for Installation of Drain Pan Heater
DRAIN PAN HEATER P36981- M1B19 Two-dimensional bar code is a code for manufacturing. MODELS: KEH041A4, KEH041A47, KEH041A48 Safety Considerations for Installation of Drain Pan Heater Read these SAFETY
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510
TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before
More informationKyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings
Contents 1. General Warnings --------------------- 1 2. Safety Warnings ----------------------- 2 3. Parts and structure --------------------- 7 4. Safety Device ------------------------- 9 5. Checkups
More informationSi Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1
Si71-812 Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1 Heat Reclaim Ventilation - with DX coil - VKM 50GAV1 VKM 80GAV1
More informationUser s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
WALL MOUNT SERIES www.windsterhood.com User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed
More informationUser s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.
TABLE OF CONTENTS 1 Table of Contents www.windsterhood.com Safety Information... 2 3 WALL MOUNT SERIES User s Manual RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS NOTE: PLEASE
More informationInstallation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E
EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338
TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!
More informationINSTALLATION MANUAL. BP (Branch Provider) Unit. Models BPMKS967A2B BPMKS967A3B BPMKS967B2B BPMKS967B3B. Installation manual BP (Branch Provider) Unit
INSTALLATION MANUAL BP (Branch Provider) Unit Installation manual BP (Branch Provider) Unit English Installationsanleitung BP-Gerät (Abzweigdose) Deutsch Manuel d installation Unité BP (Fournisseur de
More informationHeat Recovery Ventilator with DX Coil 0CED0-01A
0CED0-01A 0CED0-01A 1. External Appearance 2. Models List 3. Model Number Nomenclature 4. Structures 5. Specifications 6. Dimensions 7. Wiring Diagram 8. Fan Performance 9. Capacity Tables 10. Sound Level
More informationUser s Manual WS-5830SS WS-5836SS WS-5842SS
www.windsterhoocom UNDER CABINET SERIES User s Manual WS-5830SS WS-5836SS WS-5842SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit
More informationMystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)
Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay
More information1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan
1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan Hand Dryer Model JT-SB216ESH-W-CE Installation Manual Single-phase 220-240VAC For dealers and installers The Instruction Manual and Usage Sticker
More informationUser s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )
www.windsterhood.com User s Manual LINER SERIES WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON
More informationInstantaneous Oil-Fired Water Heater. Installation Manual OM-180
Instantaneous Oil-Fired Water Heater Installation Manual MODEL OM-180 IMPORTANT THIS APPLIANCE SHOULD BE INSTALLED BY A LICENSED, AUTHORIZED PERSON(S) DUE TO THE NECESSITY OF MAKING ELECTRICAL, WATER AND
More informationDecentralised ventilation units
Notes on installation Decentralised ventilation units FSL / SCHOOLAIR GB/en TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de
More information20-GALLON MOBILE PARTS WASHER OWNER S MANUAL
20-GALLON MOBILE PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in
More informationExternal heater hot tub
External heater hot tub User and maintenance manual Koriks-Fiiber OÜ 2018 Table of contents 1 General information... 3 1.1 Symbols... 3 1.2 Definitions... 4 1.3 Warnings... 4 1.4 Manufacturer s information...
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationInstallation instructions for the T 9820 Gas Dryer
Installation instructions for the T 9820 Gas Dryer The T 9820 gas dryer is only approved for use in the USA and Canada. It is not approved for use in Mexico. To prevent accidents en - US, CA and machine
More informationInstallation Instructions
Evaporator Coil A Coil --- Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationDesoldering Tool. Instruction Manual
Desoldering Tool Instruction Manual Thank you for purchasing the Hakko 472D desoldering tool with digital temperature display. Please read this manual before operating the Hakko 472D. Keep this manual
More informationINSTALLATION MANUAL Duct Type Series MH FECA
INSTALLATION MANUAL Duct Type Series MH FECA ENGLISH FRANÇAIS ESPAÑOL Free Joint Multi Air Conditioner (Cooling and Heating) E S F DB98-960A() Safety Precautions The following safety precautions must be
More informationDAIKIN AIR CONDITIONER
3P226011-1A M07B242A DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual
More informationtechnical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air
technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationUser s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.
www.windsterhood.com User s Manual WS-63TB36SS WS-63TB42SS ISLAND SERIES NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed
More informationVIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA
VIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA TABLE OF CONTENTS Installation------------------------------------------------------------------------------------------- 3 Reversible Door-------------------------------------------------------------------------------------
More informationDual Column Dehydrating Breather Manual
Dual Column Dehydrating Breather Manual DCB-MANUAL 1.6 Read and understand this manual prior to operating or servicing the products. SPX Transformer Solutions, Inc., Service & Components Division U.S.
More informationInstallation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542
Millennia Island (Ceiling Mount) Range Hoods Models: DHI361, DHI421, DHI482 and DHI542 Installation Instructions Approved for use with all dacor ranges and cooktops. IMPORTANT: INSTALLATION OF THIS HOOD
More informationWH-TD20B3E5 WH-TD30B3E5
Order No: PHAAM1004143C2 WH-TD20B3E5 WH-TD30B3E5 WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain
More informationIntegrated Hood Liner
Integrated Hood Liner Covers models IHL30, IHL36, IHL42, IHL48 and IHL54 Installation Instructions Part No. 65268 Rev. F 2007 Dacor, all rights reserved. Table of Contents Before You Begin... 1 Important
More informationInstallation Instructions
Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper
More informationTABLE OF CONTENTS REFRIGERATOR-FREEZER. Model No. NR-BN34FX1 Model No. NR-BN34FW1
Order Number GORR1405001CE REFRIGERATOR-FREEZER Model No. NR-BN34FX1 Model No. NR-BN34FW1 Product-Color X:Stainless W:White Destination E(Europe Continental) B(U.K.) TABLE OF CONTENTS PAGE 1 Safety Precautions-----------------------------------------------
More informationUser s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS
www.windsterhood.com User s Manual UNDER CABINET SERIES WALL MOUNT SERIES WS-3230SS WS-3236SS WS-3242SS WS-3248SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY
More informationQuest Power Electric Heat EHS 62 Pro
Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection
More informationInstallation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM1403DT-A RAV-SM1603DT-A. Model name: Concealed Duct High Static Pressure Type
AIR CONDITIONER (SPLIT TYPE) Indoor Unit Not accessible to the general public Model name: Concealed Duct High Static Pressure Type RAV-SM1403DT-A RAV-SM1603DT-A Thank you very much for purchasing TOSHIBA
More informationOA Processing unit GUF-RD4, GUF-RDH4
Processing unit DT G GUFRD4, GUFRDH4 I. Processing unit. SPEIFITIOS... 27 2. SOUD EVES... 28 2. Measurement ondition... 28 22. curves... 28. F HRTERISTIS URVES... 29 4. EXTER DIMESIOS... 240 5. EETRI WIRIG
More informationTECHNICAL & SERVICE MANUAL. Ceiling Concealed
STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A
More informationRAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL
AIR CONDITIONER (SPLIT TYPE) Installation Manual Indoor Unit Model name: For commercial use Pour usage commercial Concealed Duct Type RAV-SP8BT-UL RAV-SP4BT-UL RAV-SP30BT-UL RAV-SP36BT-UL RAV-SP4BT-UL
More informationTABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.
Installation NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION... 2 Inspect Equipment... 2 Select
More informationTable of Contents. Safety Information Content Checklist Measurements Preparation Installation
TABLE OF CONTENTS 1 Table of Contents Safety Information... 2 3 Content Checklist... 4 Measurements... 5 Preparation... 6 Installation... 7 8 Installation Diagram... 9 Operation & Features... 10 Cleaning
More informationInstallation Instructions
Installation Instructions For NoFrost Combined Refrigerator-Freezers with IceMaker CS/CBS 20 7084 337-00 Important Please Read and Follow these Instructions These instructions contain Danger, Warning and
More informationOperation Manual RANGE HOOD
Operation Manual RANGE HOOD MODEL: BUF-03A TABLE OF CONTENTS Safety Instructions... 2 Name of Parts... 4 How to Use... 5 Operating the Range Hood... 5 Care and Maintenance... 6 Disassembling... 7 Cleaning...
More informationSUBMERSIBLE DIRTY WATER PUMP
SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP100A, DWP150A, DWP200A PART NO: 7230098, 7230099, 7230100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117 - ISS 2 INTRODUCTION Thank you for
More informationInstallation Instructions
Installation Instructions For Cased Coils Upflow-Downflow Heating-Cooling CK5A CK5B SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation NOTE: Read the entire instruction
More informationModels: GW/R-T GW/R-2-T GW/R-3-T
Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly
More information