Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Size: px
Start display at page:

Download "Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input"

Transcription

1 Product Data 58EFA Horizontal Gas Furnace 50, ,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the competitive market of mid-efficiency gas furnaces. The 58EFA furnace offers dependable and economical heating. The 58EFA utilizes an intermittent ignition system which ignites the pilot eliminating a gas-wasting continuous pilot. The 58EFA incorporates control of ignition, inducer, and blower operation into 2 printed-circuit boards, resulting in a reliable and uncomplicated system. Induced combustion contributes significantly to the heat transference efficiency of the 58EFA. A corrosion-resistant steel heat exchanger extracts heat in the 58EFA and conveys it to the airstream that warms the home. This heat exchanger is the clam-shell type utilized for years because of its reliability. All these features result in a furnace that will not only heat your home comfortably for many years to come, but do it with an Annual Fuel Utilization Efficiency (AFUE) of 80%. The 58EFA is easy to install, which means lower installation costs. At 50- in. long, it can be conveniently employed in either new or replacement applications. The furnace can be field reversed for left or right gas, electrical, and vent pipe connections and is equipped with adjustable blower speeds to fit most applications. Carrier makes adjusting blower speeds easy with a speed-tap selector located on the blower motor. There is no need to remove the blower or perform other complex procedures. Copyright 1993 Carrier Corporation This document was created with FrameMaker Form 58EFA-2PD

2 With a Carrier gas furnace, your options are open when it comes to expanding your comfort system air conditioners, humidifiers, and electronic air cleaners are among the offerings. A factory-installed 40-va transformer, air conditioner relay, and multispeed blower simplify the installation of add-on options. Carrier s 58EFA Horizontal Gas Furnace heat exchangers are backed by a 10-year warranty. See your dealer for more details. 58EFA FEATURES/ BENEFITS Certifications The 58EFA units are A.G.A. and C.G.A. design certified for use with natural and propane gases. The efficiency is GAMA efficiency rating certified. The 58EFA surpasses California minimum seasonal efficiency requirements, and meets the oxides of nitrogen (NOx) emission levels set by South Coast and Bay Area Air Quality Management Districts in California. Warranty 10-year warranty on the heat exchangers, 1-year warranty on control boards. Your dealer has details. Intermittent Ignition No continuous-pilot flame to waste gas or cause problems. Redundant Gas Valve Shuts off gas to burners if 1 of the valves fails to close completely for any reason. Insulation Foil-faced insulation in heat exchanger section of the casing minimizes heat loss. Printed-Circuit Board Controls sequencing and furnace operation. Solid-state blower control actuates blower after main burners ignite to eliminate cold air blowing into rooms. Adjustable Blower Speed For precise airflow selection. Monoport Burners The burners are finely tuned for smooth, quiet combustion plus economical gas usage. C C X X Y D1 HONEYWELL G W C Y R HEAT EXCHANGER A91194 PRINTED-CIRCUIT BOARD A91333! WARNING Explosion hazard. Can cause serious injury or death. This device can malfunction if it gets wet. Never try to use a device that has been wet replace it. REV. A MPLS.. MN S8600H 100% SHUTOFF IP 90 SEC. L.O. 24V, 60 Hz PV=1A MAX., MV=1A MAX. AUTO IGNITION SYSTEMS ANSI Z21.20 If module has been used with vent damper, it will only work with damper connected. MV MV/PV PV (BURNER) 24V () 24V TH-W (OPT.) SPARK INTERMITTENT IGNITION CONTROL A91334 INDUCER BLOWER A

3 MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. ama CANADIAN GAS ASSOCIATION R A PP R O VED Model number nomenclature Horizontal Gas-Fired Furnace 58EFA Input Capacity ,000 Btuh ,000 Btuh ,000 Btuh ,000 Btuh Series Cooling Size (Airflow: 400 CFM per 12,000 Btuh) CFM CFM CFM Carrier accessories* ELECTRONIC AIR CLEANER HUMIDIFIER THERMOSTAT CATEGORY III VENT KIT GAS CONVERSION KIT NATURAL-TO-PROPANE* PROPANE-TO-NATURAL* UNIT SIZE * Factory authorized and field installed. Gas conversion kits are A.G.A. recognized. 31KAX 49FH See Master Price Pages KGASW01012SP KGANP1901IID KGAPN1401IID MODEL 31KAX ELECTRONIC AIR CLEANER A91465 Cleans the air of smoke, dirt, and many pollens commonly found in the air. Saves on decorating and cleaning expenses. MODEL 49FH HUMIDIFIER A91365 By adding moisture to winter-dry air, a Carrier humidifier can often improve comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. 3

4 A91336 NOTE: The 58EFA Furnaces are for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. NOTE: Component location and configuration may be different than shown above. ➊ Burner Assembly with Intermittent Ignition (Inside) ➋ Gas Control Valve ➌ Vent Pipe Connection ➍ Inducer Motor Assembly ➎ Blower Assembly (Inside) ➏ Control Box ➐ Pressure Switch ➑ Heat Exchanger 4

5 Physical data UNIT SIZE OUTPUT CAPACITY BTUH (Nonweatherized ICS) 40,000 60,000 80, ,000 INPUT BTUH* 50,000 75, , ,000 SHIPPING WEIGHT (Lb) CERTIFIED TEMP RISE RANGE ( F) CERTIFIED EXT STATIC PRESSURE (In. wc) Heating Cooling AIRFLOW CFM Heating Cooling LIMIT CONTROL HEATING BLOWER CONTROL * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4% for each 1000 ft above sea level. In Canada, derate the unit 10% for elevations 2000 to 4500 ft above sea level. Capacity in accordance with U.S. Government DOE test procedures. ICS Isolated Combustion System SPST Solid-State Time Operation BURNERS (Monoport) GAS CONNECTION SIZE GAS VALVE (Redundant) Manufacturer Minimum Inlet Pressure (In. wc) Maximum Inlet Pressure (In. wc) IGNITION DEVICE 1/2-in. NPT Honeywell 4.5 (Natural Gas) 13.6 (Natural Gas) Intermittent Dimensions (In.) A B ELECTRICAL CONNECTION B 5 8 A AIR FLOW VENT CONNECTION T-STAT CONNECTION C ( NUMBER OF TUBES) COMBUSTION AIR CONNECTION 1 2 GAS CONNECTION A91337 UNIT SIZE UNIT WIDTH DUCT SUPPLY AND RETURN OPENINGS NUMBER OF HX A B C /2 11-1/ /2 11-1/ / /2 18-1/8 5 5

6 CLEARANCES (In.) UNIT SIZE , , , and SIDES 6* BACK 6* TOP 2* VENT CONNECTOR 6* FRONT CASING 6* FRONT SERVICE 30** * Measured from end of inducer motor. Performance data PSC Permanent Split Capacitor UNIT SIZE DIRECT-DRIVE MOTOR Hp (PSC) 1/3 1/3 1/3 1/2 MOTOR FULL LOAD AMPS RPM (Nominal) SPEEDS BLOWER WHEEL DIAMETER WIDTHS (in.) 10x8 10x8 12x9 12x12 FILTER SIZE (in.) (WASHABLE) 13x23x1 16x23x1 20x23x1 EFFICIENCY FURNACE MODEL 58EFA CAPACITY* Nonweatherized ICS 40,000 60,000 80, ,000 AFUE %* Nonweatherized ICS * Capacity and AFUE in accordance with U.S. Government DOE test procedures. California Seasonal Efficiencies based on California-specified procedures. ICS Isolated Combustion System UNIT SIZE * Airflow values in cubic ft per minute (CFM), rounded to nearest 5 CFM. AIR DELIVERY CFM* (Without Filter) EXTERNAL STATIC PRESSURE (in. wc) SPEED High Med Low High Med Low High Med Low High Med Low

7 Electrical data UNIT SIZE UNIT VOLTS HERTZ PHASE MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH* (Ft) MAXIMUM UNIT AMPS OPERATING VOLTAGE RANGE (Min Max) MAXIMUM FUSE SIZE OR HACR-TYPE CKT BKR (Amps) TRANSFORMER (24v) EXTERNAL CONTROL POWER AVAILABLE Heating 12VA Cooling 21VA AIR CONDITIONING BLOWER RELAY * Length shown is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. Permissible limits of the voltage range at which the unit will operate satisfactorily. Time-delay fuse is recommended. 40VA Standard Typical wiring schematic FIELD 24-VOLT WIRING FIELD 115-, 208/230-, 460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-, 208/230-, 460-VOLT WIRING FOUR WIRE G W Y R THERMOSTAT TERMINALS FIELD-SUPPLIED FUSED DISCONNECT 115-VOLT SINGLE PHASE 115-VOLT FIELD-SUPPLIED FUSED DISCONNECT TWO-WIRE HEATING- ONLY G W Y C R 24-VOLT TERMINAL BLOCK CONDENSING UNIT TWO WIRE 208/230- OR 460-VOLT THREE PHASE 208/230- VOLT SINGLE PHASE NOTE : 1. Connect Y-terminal as shown for proper cooling operation. 2. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. 3. Proper polarity must be maintained for 115-volt wiring. A

8 Typical installation A91339 Carrier Corporation Syracuse, New York Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 Catalog No Printed in U.S.A. PC 101 Form 58EFA-2PD Tab 6a 8a Replaces: 58EFA-1PD

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price Product Data 58PAV Energy-Efficient Induced-Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80 percent Annual Fuel Utilization Efficiency

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh HETING & COOLING Product Data 58GF High-Efficiency Induced-Combustion Upflow Furnace Heating Inputs: 65,000 150,000 Btuh 78% FUE With Continuous- Pilot Ignition Carrier is the first manufacturer to provide

More information

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh Product Data 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace Series 120 Input Capacities: 40,000 thru 135,000 Btuh Comfort Heating for Energy-Efficient Gas Furnaces Carrier leads

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh Product Data 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace Series 50 and 60 Input Capacities: 45,000 thru 55,000 Btuh Advanced Technology for Energy-Efficient Gas Furnaces Carrier leads

More information

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh *High Efficiency and Flexibility Designed to Meet the Needs of New Homes

More information

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace Product Data 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace Series 120 and 130 Input Capacities: 40,000 thru 135,000 Btuh Comfort Heating for Energy-Efficient Gas Furnaces

More information

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh High Efficiency and Flexibility Designed to Meet the Needs of New Homes The

More information

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh HEATING & COOLING Product Data 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh 4-way Multipoise Design Allows More Applications...

More information

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation Product Data 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces 58BLA Low-Boy AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY ama 58BMA 3-Way Multipoise 58BTA Upflow/Horizontal Copyright 1996 Carrier Corporation

More information

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CLA Low-Boy Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CLA combines high efficiency and quiet operation with oil heating

More information

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CMA Multipoise Oil Furnace Series 120 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the

More information

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CMA Multipoise Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the

More information

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE MULTIPOISE CONDENSING GAS Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed

More information

395CAV Sizes 045 thru 155 Series H and J

395CAV Sizes 045 thru 155 Series H and J ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE 395CAV Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh Efficiency and Flexibility Designed to Meet the Needs of New

More information

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace Series 121 Input Capacities: 4, thru 12, Btuh U L T R A H I G H E F F I C I E N C Y G A S F U R N A N C E Variable capacity,

More information

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning. Time Roman INSTALLATION FLEXIBILITY: CASING: COMBUSTION SYSTEM: 3-PASS PRIMARY HEAT EXCHANGERS: FLOW-THROUGH SECONDARY HEAT EXCHANGERS: LIMITED WARRANTY: MONOPORT INSHOT BURNERS: The 4-way multipoise design

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150 4 --- WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150 Product Data THE CARRIER GAS FURNACE The 4 -way Multipoise Gas Furnaces feature Carrier

More information

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURCE Product Data A9801 Utilizing the extensive resources available to Payne, a new standard of excellence has been achieved with the model. The model is a unique

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

Product Data. 58WAV Weathermaker 8000 High-Efficiency Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58WAV Weathermaker 8000 High-Efficiency Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh HETING & COOLING Product Data 58WV Weathermaker 8000 High-Efficiency Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh dvanced Technology for High-Efficiency Gas Furnaces Carrier leads the industry

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS MULTIPOISE CONDENSING GAS FURCE Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed

More information

Cooling Capacity CFM range

Cooling Capacity CFM range R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and

More information

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160 4 --- WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160 Product Data THE CARRIER GAS FURNACE The 4 -way Multipoise Gas Furnaces feature Carrier s QuieTecht

More information

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY Multipoise Oil Furnace Input Capacities: 70,000 thru 154,000 Btuh eries 130 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06625 The model combines high efficiency and quiet operation with oil heating

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall 310AAV/310JAV 4 -Way Multipoise Induced Combustion Gas Furnace Sizes 045 thru 155 Series G Product Data STANDARD FEATURES S Noise elimination combustion system S Four-position furnace: Upflow, Horizontal

More information

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES Product Data Model BW9 Gas-Fired Condensing Water Boiler Series A best way to obtain plenty of clean combustion air. The induced draft fan draws in the outside combustion air, then takes the cooler flue

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS MULTIPOIE OIL FURNACE INPUT RATE: 70,000 thru 154,000 BTUH ERIE 130 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06625 The model combines high efficiency and quiet operation with oil heating technology.

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price Product Data 58RAV High-Efficiency Downflow/Horizontal Induced-ombustion Gas Furnace Input apacities: 50,000 thru 5,000 Btuh 80% AFUE At Budget Price DOWNFLOW HORIZONTAL arrier provides an 80% Annual Fuel

More information

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control COMFORT 80 DELUXE 4---WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 150 Product Data STANDARD FEATURES S QuieTecht noise reduction system S SmartEvapt

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise % 96AFUE 2-Stage Variable-Speed % 95AFUE 2-Stage Multi-Speed Multipoise % 92AFUE Multipoise % AFUE 2-Stage Variable-Speed Multi-Speed Multipoise 86 87 96 % AFUE 2-Stage, Variable-Speed Up to 96 AFUE Variable-speed

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

355MAV Sizes 040 thru 120 Series E

355MAV Sizes 040 thru 120 Series E DELUXE 4-WAY MULTIPOISE VARIABLE-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 355MAV Sizes 040 thru 120 Series E HIGH EFFICIENCY GAS FURNACE VARIABLE CAPACITY SYSTEM THE INTELLIGENT ING MACHINE Building

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-452 REV. 3 Supersedes Form No. G66-452 Rev. 2 GAS FURNACES WGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (U.S. & Canadian Models) (All Models 90% A.F.U.E.

More information

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 Product Data A0086 The model Multipoise Condensing Furnace is specifically designed to meet the needs of the new construction market.

More information

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40. HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 350MAV Sizes 040 thru 140 Series D Utilizing the extensive resources available to Bryant, a new standard of excellence

More information

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION FORM NO. G11-442 REV. 6 Supersedes Form No. G11-442 Rev. 5 GAS FURNACES RGDG- SERIES Standing Pilot Models with Input Rates from 45,000 to 150,000 BTU/HR [13 to 44 kw] (U.S. & Canadian Models) ENER UIDE

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. GSC-497 REV. 2 Supersedes Form No. GSC-497 Rev. 1 GF901U SERIES Models with Input Rates 45,000, 60,000, 105,000 & 120,000 BTU/HR [13.19, 17.58, 30.77, & 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B BW1, BW2 & BW3 Gas-Fired Water Boilers Series B Product Data MODEL BW1, BW2 Series B MODEL BW3 Series B MODELS BW1, BW2, and BW3 Models BW1 and BW2 Gas-Fired Hot Water Boilers provide fast heat quietly

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit /PHY PERFORMANCE BOOST 80 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh Series 100 Product Data multipoise design, through -the-furnace downflow venting,

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable LOW --- BOY OIL FURNACE INPUT CAPACITIES: 77,000 THRU 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10232 The models OBL and OVL combine high efficiency and quiet operation with oil heating

More information

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G22-473 REV. 3 Supersedes Form No. G22-473 Rev. 2 GAS FURNACES UGPL- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR [15 to 37 kw] (U.S. & Canadian Models) Annual Fuel

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Downflow/Horizontal Right Induced Draft Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion

More information

Ruud Achiever Series Multi position Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev. 036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R

More information

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh PERFORMANCE BOOST 90 4 --- WAY MULTIPOISE 2 --- STAGE CONDENSING GAS FURCE Input Rates: thru 1,000 Btuh Product Data 4 -WAY MULTIPOISE DESIGN ALLOWS MORE APPLICATIONS design, the secondary heat exchanger

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage, Variable Speed Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER variable speed ECM blower motor Supports two stage cooling units

More information

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-452 REV. 10 Supersedes Form No. G11-452 Rev. 9 GAS FURNACES RGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Rheem Classic Series Downflow/ Horizontal Gas Furnaces Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10311 The models OBM and OVM combine high efficiency and quiet operation with oil heating

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System

More information

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-498 Supersedes Form No. P66-765 Rev. 3 90TS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL

More information

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,

More information