RT-OA TM Rooftop Outdoor-Air (DOAS)
|
|
- Buck Fitzgerald
- 5 years ago
- Views:
Transcription
1 RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...! Features & Benefits ASHRAE Compliant 44-18, CFM (3-6 Tons) DX Air Cooled, Water Cooled & Heat Pumps Systems Down-Flow & Horizontal Air Patterns Powder-Coat Painted Heavy Duty Steel Cabinet & Frame Double-Wall (2 ) Panel Construction Inner-Lined with Rigid Polyurethane Foam (R-13 or Greater Value) Hot Gas Reheat (modulating) Digital Scroll Compressors Provide Precise Part-Load Control Backward-Inclined Direct-Drive Variable Speed EC Plenum Fans ElectroFin E-coat or Heresite Coated Coils Options Low Ambient Head Pressure Control Power Exhaust & Return Air Options Electric, Gas Fired & Hot Water Heat Options RT-OA - DOAS Rooftop Outdoor-Air Units (RTOA-LB1.) 1
2 INTRODUCTION AboveAir RT-OA Outdoor Air Rooftop Dedicated Outdoor Air Systems (DOAS) are designed to provide year-round treatment of your ventilation requirements. Systems are available from 44-18, CFM (3-6 Tons) in a variety of dehumidfication & heating methods. RT-OA systems incorporate energy saving precision control variable speed digital scroll technology along with total energy recovery wheels, modulating gas fired or SCR electric heat options. Down-Flow Air Pattern CONDENSER AIR INLET CONDENSER AIR OUTLET EVAP SUPPLY AIR OUTLET EVAP RETURN AIR INLET OUTDOOR AIR INLET EXHAUST AIR OUTLET Horizontal Air Pattern CONDENSER AIR OUTLET CONDENSER AIR INLET OUTDOOR AIR INLET EXHAUST AIR OUTLET EVAP RETURN AIR INLET EVAP SUPPLY AIR OUTLET ASHRAE Compliant R41a Refrigerant Modulating Digital Scroll Technology Flexible Options and Accessories Ease of Serviceability Contents Introduction...2 Features and Benefits...3 Configuration Opitons Overview Energy Recovery & Controls Nominal Performance Data...8 Additional AboveAir Products Introduction
3 FEATURES & BENEFITS RT-OA Outdoor Air (44-18, CFM (3-6 Tons)) Variety of Standard & Optional Features Standard Features: MC-3/5/7-OA Advanced Micro Controls Digital Scroll Compressors (1 or 2 Circuits) Backward-Inclined Direct-Drive EC Plenum Fans Painted Steel Cabinet & Frame Construction R-13 Double-Wall (2 ) Rigid Polyurethane Foam Panel Construction Sloped Stainless Steel Drain Pan w/ Overflow Switch Hot Gas Reheat with Modulating 3-Way Valve Aluminum Fin / Copper Tube Coils Low Leakage AMCA Certified Dampers TXV, Refrigerant Filter-Driers & Sight-Glasses High & Low Refrigerant Pressure Switches 2 Merv-8 Pre & 4 Merv-13 Final Filters Intertek (ETL) Listed per UL1995 Test Standard Optional Features & Accessories: Total or Sensible Energy Recovery Wheel Electric SCR Fired Heat Gas Fired Heat (Modulating Control) Power Exhaust & Return Air Variable Air Volume (VAV) Control Options BMS Communications (BACnet or ModBus) ElectroFin E-coat or Heresite Coated Coils Modulating Head Pressure Control (Standard) Main Power Electrical Disconnect CO 2 Sensor, Smoke Detector & Firestat Roof-Curbs Split Condensing Unit Option Air Source or Water Source Heat Pump... Additional Options Available! Features & Benefits 3
4 Configuration Options 4 Configuration Options
5 Configuration Options... Continued Configuration Options 5
6 Energy Recovery Wheel - Overview INDOOR AIR QUALITY ENERGY RECOVERY FLUTED WHEEL MEDIA UNITARY WHEEL CASSETTE UWC / UWCH UWC/UWCH KEY BENEFITS Independently tested & AHRI certified wheel performance High Enthalpy Performance = Less Pressure Loss, Less Fan Energy, More Energy Savings, Low operating costs The SEMCO Unitary Wheel Cassette (UWC) Series, a sensible and latent energy recovery aluminum desiccant wheel, is designed and packaged as the HVAC industry s first drop in replacement for most OEM wheels used by packaged rooftop unit manufacturers. Use of the AHRI Certified mark indicates a manufacturer s participation in the certification program. For verification of certification for individual products, go to High latent AND sensible heat transfer efficiencies Highest Recovery Efficiency Ratios (RER) available in the industry Industry-leading indoor air quality device through minimized desiccant cross contamination Integrated purge section option Wheel independently certified to pass NFPA 9A requirements for flame spread and smoke generation and ASTM E84 fire test method Proven reliable operation The UWC Series 3-3/4-inch-wide (1-mm) wheels feature a fast-acting, corrosion-resistant, proprietary desiccant that s applied to a sturdy, but lightweight all-aluminum wheel substrate. The honeycomb matrix s fluted opening design efficiently produces maximum latent and sensible air-to-air heat transfer, but generates up to 5-percent less HVAC system static pressure than polymer film wheels. Besides assisting buildings in surpassing ASHRAE 9.1 building energy compliance, the aluminum wheels also have longer life cycles and vastly less periodic maintenance requirements than polymer wheels and can withstand temperatures of up to 18 F. Low maintenance Proven long life expectancy 6 Controls Options
7 Control Options Variety of High Percentage Outdoor-Air (HPOA) Control Options SENSIBLE HEAT RATIO = Qs / Qt PSYCHROMETRIC CHART NORMAL TEMPERATURE I-P Units SEA LEVEL BAROMETRIC PRESSURE: IN. OF MERCURY SENSIBLE HEAT Qs TOTAL HEAT Qt.2.1 ENTHALPY h HUMIDITY RATIO W ENTHALPY - BTU PER POUND OF DRY AIR 35 SATURATION TEMPERATURE - F Dehumidifica on Dehumidifica on Enable Set Point DEW POINT TEMPERATURE - F ENTHALPY - BTU PER POUND OF DRY AIR Sensible Hea ng Hea ng Enable Set Point Vent Only Chart by: HANDS DOWN SOFTWARE, DRY BULB TEMPERATURE - F Cooling Enable Set Point Sensible Cooling SENSIBLE HEAT RATIO = Qs / Qt MC-3/5/7N - Space Neutral MC-3 / MC-5 / MC-7 (Advanced Dewpoint Controls) The MC-3/5/7N control sequence provides a constant, neutral supply air temperature for make-up air, space pressurization, or as a parallel outdoor air source. These systems are typically 1% outdoor air. MC-3/5/7P - Space Primary The MC-3/5/7P control sequence provides temperature and humidity control of a single zone. This control sequence is applied for high percentage outdoor air situations (>2% OA) where a single unit is required to meet both the outdoor air requirement, as well as, controlling the space temperature. MC-3/5/7V - Variable Air Volume (VAV) The MC-3/5/7V control sequence is a variable air volume sequence intended to provide a constant supply air temperature and vary fan speed according to the system static pressure for units with high percentage outdoor air (>2% OA) where the ability to maintain dehumidification while resetting the supply air temperature is a concern. It serves multiple zones where each zone is provided with a VAV box with reheat. MC-3/5/7Z - Single Zone VAV The MC-3/5/7Z control sequence is a variable volume control sequence which provides temperature and humidity control of a single zone. Both the fan speed and supply air temperature will vary according to the requirements of the single zone. The outdoor air percentage should be no greater than 2%. Controls Options 7
8 TECHNICAL DATA Performance Data: Cabinet Size AboveAir RT-OA TM Outdoor Air Units - Cooling Performance (DX - Air Cooled Data) AboveAir Model Nominal Tonnage 1% Outside-Air Airflow Range 1% OA with Energy Recovery Wheel (ERW) Airflow Range "A" RT-OAA-_-A_3/5 3-5 Tons CFM 9-1,49 CFM "B" RT-OAB-_-A_6/1 6-1 Tons 87-1,44 CFM 1,79-2,98 CFM "C" RT-OAC-_-A_12/ Tons 1,73-2,59 CFM 3,58-5,36 CFM "D" RT-OAD-_-A_2/3 2-3 Tons 2,87-4,31 CFM 5,96-8,93 CFM "E" RT-OAE-_-A_4/6 4-6 Tons 5,74-8,61 CFM 11,91-17,86 CFM Note: Cooling Capacity based on: 95 F DB/78 F WB OA, 55 F DB/54 F WB LAT Additional AboveAir Products SC - 2x4 SpotCool Comfort & Precision (1 to 3 Tons) HK - Horizontal Comfort, Precision & HPOA (1 to 3 Tons) VK - Vertical Comfort & HPOA (1 to 45 Tons) Floor Console Precision (1 to 3 Tons) MC - MissionCritical Vertical Data Center Precision (1 to 3 Tons) Remote Air Cooled Condensers, Condensing Units & Glycol Drycoolers (1 to 18 Tons of THR) Single, Dual & Triplex Glycol Pump Packages (1/2 to 5 HP) Mountville Road Frederick, Maryland 2173, U.S.A. Phone: , Facsimile: sales@aboveair.com Copyright 9/18 Form: RTOA-LB1. Specifications are subject to change without notice.
RT-OA TM Rooftop Outdoor-Air (DOAS)
RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS (DX - Air Source Data) Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels,
More informationRooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating
Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged
More informationTHE ULTIMATE ROOFTOP SOLUTION
Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly
More informationEnergy Recovery with Cooling and Heating Model ERCH
Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,
More informationTHE RIGHT SPEC. RIGHT NOW.
THE RIGHT SPEC. RIGHT NOW. 6-12.5 TONS R7DA Gas/Electric Packaged DOAS System MADE FOR THOSE WHO RESPECT THE SPEC. Reznor light commercial packaged rooftops are highly configurable at the factory, so consultant
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationPACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationEnergy Recovery with Cooling and Heating
Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model
More informationPINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION
ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy
More informationRN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationAlpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018
Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum
More informationFundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer
Fundamentals of Psychrometrics By James L. Murphy, Colorado Building Environments Sales Engineer Let s s Start with Air Air is Made up of Two Main Gases Nitrogen (77%) Oxygen (23%) If that is all there
More informationD-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)
More informationDesigning Energy Efficient Outdoor Air Systems
Designing Energy Efficient Outdoor Air Systems Joseph Thorndal Applied Products Sales Manager Greenheck, Schofield, Wisconsin 1 Joseph Thorndal BS Industrial Engineering North Dakota State University Work
More informationThe ultimate fresh air solution.
Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum and reduced maintenance Double wall rigid polyurethane foam injected panel
More informationHeat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:
Heat Pumps M2 SERIES Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Water-source and geothermal heat pump self-contained units with capacities from 3-70 tons 10%-100% variable
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationSubmittal Data Performance Data Electrical Data
ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationHeat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:
Heat Pumps SB SERIES SB Series Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved
More information62DA,DB,DC,DD,DE,DF07-38
62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationEP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT
ENERGY EFFICIENT AIR COMFORT EP SERIES PACKAGED ENERGY RECOVERY SYSTEM Certified total energy recovery performance (sensible and latent) up to 90% efficient. Double-wall panel construction eliminates exposed
More informationBring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M
Bring the fresh in. D E D I C AT E D O U T S I D E A I R S Y S T E M Breathe easier. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting
More informationALL PRODUCTS BROCHURE
ALL PRODUCTS BROCHURE www.aaon.com d e d i c at i o n t o cust o m e r service since the founding of aaon in 1988, we have maintained our commitment to design, develop, manufacture and deliver heating
More informationVH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control
VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Unit with Enhanced Humidity Control Motorized Bypass Damper Temperature and Humidity Controller Reheat Control Elastomeric Foam Insulation High Efficiency,
More informationEnergy Recovery Ventilators
Energy Recovery Ventilators Models ERM, MiniVent, ERV and ERVe Untempered Preconditioners September 2016 Energy Recovery Ventilators Greenheck offers a complete line of energy recovery ventilators to reduce
More informationMulti-Path RTU-TYPE 2
ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 2 (RTU1) CESMPU025RHVAV2 Date: February 17, 201 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV2 Unit features include: 25 Ton MultiPath
More informationRoofPak Applied Rooftop Systems
RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution
More informationPRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series
PRODUCT SERIES VPR Series VPRX Series VPRE Series VPRP Series VPRC Series Valent Air Management Products Valent Air Management Systems designs and manufactures reliable, high-outdoor-air ventilators. Our
More informationHeat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:
Heat Pumps SB SERIES Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved plenum supply fans for improved energy Double wall rigid polyurethane
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationCultivator & Hybrid Cultivator
Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on
More informationProduct Release Summary
Product Release Summary 48/50HC with System March 2012 TC Benefits of EnergyX System Why Energy Recovery 1. Code requirements: ASHRAE 90.1-2004: Energy Recovery is required when design supply air capacity
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION
More informationDOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR
MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR KITCHENS HOTEL CORRIDORS LABORATORIES CONFERENCE CENTERS SCHOOLS PAINT BOOTHS MALLS/SHOPPING CENTERS DOAS UNITS Capacities 5-30 Tons 50-800 MBH 30-120 kw 650-9,000
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationPsychrometrics: The Science of Moisture in Air. Presented by Tom Peterson, CEO and Founder. Climate by Design International
Psychrometrics: The Science of Moisture in Air Presented by Tom Peterson, CEO and Founder Climate by Design International www.cdihvac.com Owatonna, MN 507-451-2198 4 02/2014 1 Psychrometrics or psychrometry
More informationSECTION (15733) - DEDICATED OUTDOOR AIR UNITS
PART 1 GENERAL 1.01 SUMMARY SECTION 23 74 33 (15733) - DEDICATED OUTDOOR AIR UNITS A. Section Includes: 1. Dedicated Outdoor-Air Units with Energy Recovery B. Related Sections: 1.02 REFERENCES 1. Section
More informationMaverick II Commercial Rooftop Systems 15 to 75 tons
Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems System performance and reliability make Maverick II commercial packaged rooftop systems the ideal solution for
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationTechnical Development Program
Technical Development Program PRESENTED BY: James Parker Insert your logo here AIR HANDLERS Coils: Direct Expansion Chilled Water and Heating Menu Section 1 Introduction Section 2 Typical Coil Applications
More informationSUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer
SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,
More informationProduct Catalog. Horizon Outdoor Air Unit For 100% Outdoor Air Applications Model: OADG OAU-PRC004A-EN. November 2017
Product Catalog Horizon Outdoor Air Unit For 100% Outdoor Air Applications Model: OADG November 2017 OAU-PRC004A-EN Introduction The Horizon Outdoor Air Unit... The Trane DX Horizon Outdoor Air Unit for
More informationAHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency
Application Note 24 AHRI 920 Performance Rating and Comparisons I NTRODUCTION In 2015, the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) introduced a performance rating for dedicated outside
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationMunters Heat Exchangers
Munters Heat Exchangers Brad Perdew Applications Engineer 8/27/12 DOAS Configurations Cheryl Hughes Regional Sales Manager October 11, 2016 cheryl.hughes@munters.com Munters DOAS Configurations Presentation
More informationSECTION (15733) - DEDICATED OUTDOOR AIR UNITS
PART 1 GENERAL 1.01 SUMMARY SECTION 23 74 33 (15733) - DEDICATED OUTDOOR AIR UNITS A. Section Includes: 1. Dedicated Outdoor-Air Units with Energy Recovery B. Related Sections: 1.02 REFERENCES 1. Section
More informationSubmittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat
SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal
More informationAHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU
AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU MULTISTACK was founded in 1989 by three highly respected, visionary HVAC industry executives.
More informationFrom 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction
From 230 tons to Water-Source eat Pump Products Premium Performance Environmentally Friendly Superior Construction Water-Source eat Pump Products Small Packaged Water-Source eat Pumps (1/2 to 30 tons)
More informationProduct Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons
Product Data 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial
More informationWall Mounted Air Conditioners with Gas Heat Models AVGA
PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety
More informationEnergy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE
This article was published in ASHRAE Journal, March 20145 Copyright 2015 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission
More informationCB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:
CB/CF CONDENSERS AND CONDENSING UNITS CF CB Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity
More informationFCC Fan-Coil Units High-Performance, Vertical
FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations
More informationProduct Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel
Product Data 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationProduct Catalog. Horizon Outdoor Air Unit Water Source Heat Pump For 100% Outdoor Air Applications Models: OABE, OADE, OAGE, OAKE, OANE OAU-PRC003C-EN
Product Catalog Horizon Outdoor Air Unit Water Source Heat Pump For 100% Outdoor Air Applications Models: OABE, OADE, OAGE, OAKE, OANE March 2016 OAU-PRC003C-EN Introduction The Horizon Outdoor Air Unit
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION
More informationDedicated Outdoor Air Systems: AHRI 920, ISMRE & ASHRAE 90.1
Dedicated Outdoor Air Systems: AHRI 920, ISMRE & ASHRAE 90.1 1 Peter Teige, Application Engineering Manager, AHRI Member Technical Training, October 12, 2016 AHRI 920: Establishes Efficiency Metric for
More informationDirect Gas-Fired Make-Up Air Models DG and DGX
Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5
More informationDCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h
Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling
More informationStandards and Guidelines. Presented by: Aric Murray December 12, 2014
TDSHS Ventilation Standards and Guidelines Presented by: Aric Murray December 12, 2014 Agenda 1. What are the TDSHS ventilation 1. What are the TDSHS ventilation requirements? 2. Pressure relationships.
More information48TM GAS HEATING/ELECTRIC COOLING UNITS
48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationEnergy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1
Energy Recovery Ventilators MCV CORE Series Page 1 Introducing enervent MCV Static Core Series New Static CORE ERV series 300-1,200 CFM (Indoor Only) CORE differentiation Unique & proprietary heat exchanger
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationCOMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume
COMMERCIAL HVAC PACKAGED EQUIPMENT Rooftop Units Level 1: Constant Volume Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application
More informationDX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM
D Units Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM INDUSTRY-LEADING HVAC MANUFACTURER Nortek Air Solutions is the largest custom HVAC manufacturer in North America, with a combined total of
More informationSeries. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost
LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable
More informationIntroduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN
Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb
More informationDES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling
DES CHAMPS PRODUCTS Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Packaged Heat Recovery Systems Micro-Z
More informationPAR5. Product Specifications
TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced
More informationRoof Top Packaged Unit (RTU-1) Specification
Roof Top Packaged Unit (RTU-1) Specification Item Tag(s) Qty Description Model Number A2 10 Ton 1 10 Ton R410A PKGD Unitary Gas/Electric TRANE: YHC120F3RLA--07C1 Product Data - 10 Ton R410A PKGD Unitary
More informationCONDENSERS AND CONDENSING UNITS
CONDENSERS AND CONDENSING UNITS CF Series Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity
More informationEP Model. EP Model Water Source Heat Pump. ½ to 6 Ton
EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.
More informationXeteX, Inc. All Rights Reserved.
Model DXH Custom, packaged, roof mounted or indoor mounted unit with cooling (DX or Chilled Water) and an air-to-air aluminum flat plate exchanger designed to provide pre-cooling and reheat. The DXH is
More informationIAQ VENTILATORS. FRESH AIR REQUIREMENTS. Applications ASHRAE 62.1, 90.1 & School / university / day care.
FRESH AIR REQUIREMENTS ASHRAE 62.1, 90.1 & 189.1 Applications Health / beauty / spa Pet shop / veterinary clinic ice / conference room School / university / day care Medical / pharmaceutical Museum / library
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:
More informationBest Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation
Best Practices for Applied Rooftop ` Systems - Application and Jerry Cohen President Jacco & Assoc. Installation Who is Jacco Established 1968 Hudson, Ohio Columbus, Ohio Toledo, Ohio Systems Knowledgeable
More informationVariable Refrigeration Flow Systems Overview 10/11/2016
Variable Refrigeration Flow Systems Overview 10/11/2016 Executed by Data Power Technology Illinois Aggressively, relentlessly anticipating and exceeding our customer s and client s expectations every day,
More informationSubmittal Summary Page
ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
More informationHeat Recovery Ventilator Model PVe Light Industrial Commercial Institutional
Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationProduct Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel
Product Data 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial
More informationGeneral unit Specification Version: August 8, 2013 Model JDMA : Make-up / Ventilation Air Page 1 of 13
Model JDMA : Make-up / Ventilation Air Page 1 of 13 SECTION 15720 Mechanical Specification Packaged Unitary Make-up and Ventilation Air ** Remove all notes shown in red with ** before use/publishing. Part
More informationPharmaceutical Facility Design
PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the
More informationIndirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)
Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.
More informationDCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
More information