Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Size: px
Start display at page:

Download "Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater."

Transcription

1 Duct Heaters Synheat duct heaters come in various sizes and dimensions to fit any compartment. There are three types of duct heaters available: open coil, tubular element or finned tubular heating elements that are either flanged or inserted in the duct. Air duct heaters are primarily used in air flowing ventilation systems and comfort heating applications while process duct heaters are mainly used for industrial process heating applications (ovens that require re-circulated air or forced circulation). A broad range of custom built electric duct heaters with capacities up to 500kW is available upon request. Our heaters can be used for applications with the following voltages: volts/1 phase volts/3 phase volts/3 phases volts/3 phases Insert Type Duct Heater Cylindrical Type Duct Heater Flange Type Duct Heater

2

3 By design, all the heaters are made non-sensitive to air flow direction. The built-in high limit thermal cut-outs are located in such a way that the air flow could be in any direction without impairing safety and the same heater could be installed in a horizontal or vertical duct. Normally, electric heaters are not designed to be used in series in a heating installation. For very large heaters, manufacturing, shipping, field handling and installation, can be simplified by using two or more units specially designed for parallel installation. Each section has its own cut-outs and terminal blocks are provided to interconnect the controls in the field.

4 Installation Instructions

5 (Insert Type, Side Slip-In, Vertical Slip-In) Installation of the slip-in heater consists of cutting an opening in the duct approximately 1/4" larger than the height and width of the heater element section. Insert heater and fasten to the duct using sheet metal screws through the control enclosure. Use extreme caution in protecting the electrical components, as metal chips lodged in the components can cause failure. Remove any metal chips that may be located in the electrical enclosure before connecting power. NOTE: To prevent element section from moving inside duct, angle clips, brackets, or blank offs should be attached to frame. Flange Type Duct Heater Installation

6 Flanged heaters are designed with the flanges turned out. Installation of the side flanged heater consists of inserting the flanged duct heater section into the duct and bolting in place. Cylindrical Duct Heater Installation of the round duct heater consists of attaching round duct to the inlet and outlet collars and bolting in place. Seal connection and duct joint. Install the control panel in a suitable location for the specified panel type. The wiring diagrams inside the heater door and the remote control panel door show point-to-point interconnecting wiring. Wiring must be letter to letter ("a" to "a") or number to number ("1" to "1"). Labels on each door specify the (heater/panel) configuration. DO NOT deviate from this label. Panels should be mounted in sight of unit, unless an additional disconnect is located at unit. We manufacturers a complete line of electric duct heaters with various physical sizes and KW/Btu/h outputs. Models from 1KW 6 round to 20KW Single and 3-phase units Thermal cut-outs or Temperature sensor option, if no heat is needed-element is off or modulated. Typical Applications Boost air temperature for any forced air system Additional heat for cold room Temper air temperature for Air to Air Heat Exchanger Air Source Heat Pump-rids you of cold air syndrome Ground Source Heat Pump boost / backup Temperature Sensing Duct Heaters Completely programmable duct sensing electric duct heater.

7 Automatically senses air temperature within ductwork Regulates electric heat output based on predetermined desired temperature. Flexible temperature ranges from degrees Power W Btu/h output CFM Voltage V Duct Size (OD) In Inches Btu/h Btu/h Btu/h , Btu/h Power W Btu/h output CFM Voltage V Duct Size (W x H) In Inches Btu/h x 8 10, Btu/h x 8 15, Btu/h x 8 20, Btu/h x 8 Finned Tubular Heaters & Unfinned Tubular Heaters Finned Tubular Heaters The most common design Include the highest wattage/cross section duct area Energy saver Made of a stainless steel tube with a corrugated stainless steel fin wrapped around it. Maximize the heat transfer surface of the element Provide lower operating temperature Designed for low maintenance Unfinned Tubular Heaters Available for approved special orders only Increase corrosion resistance High humidity environments Corrosive chemical contaminants in the air stream Protect from electrical shock Made of stainless steel tube Can be installed close to a register or grill N/A Designed for low maintenance How to select and specify for duct heaters required. Selecting the heater for your application can be done : 1- Determine heater capacity, voltage and electrical components 2- Determine duct dimensions, air requirements and mechanical options 3- Determine method of control, then select control components Calculating KW Requirements Once the volume of airflow (CFM in cubic feet per minute) and the required temperature rise (ΔT in degrees F) through the heater are known, the required kilowatt rating (KW) of the heater can be determined from the formula:

8 KW = CFM x ΔT F KW = Liters/Second x ΔT C Where the desired heating capacity in BTU/Hr is known, the KW is determined from the following formula: KW = BTU/Hr 3412 Static Pressure Drop

9 Minimum Air Velocities

10 Airflow Uniformity In order to prevent hot spots, the air flow must be uniformly distributed across the heater area. The following figures illustrate typical heater mis-application where the airflow is not uniform. An specifies that a heater should not be installed closer than 4 feet downstream or 2 feet upstream from a fan outlet, an abrupt transition, an elbow or any other kind of obstruction in the duct. If your application is such that one of the mentioned installations cannot be avoided, We can help you by designing around it. "Means shall be provided to assure uniform and adequate airflow over the face of the heater. Heaters installed near (within 4 feet) a fan outlet, elbows, baffle plates or other obstruction in duct work may require turning vanes, pressure plates or other devices in the inlet side of the duct heater to assure an even distribution of air over the face of the heater". Our heaters can be part of large air handling units. In this case, a heater becomes a module of a bigger unit and is designed to match the other components: filter frames, fans, cooling coils, VAV boxes, etc. Flanged units can be bolted directly to adjacent sections or slip-in models are inserted into a bigger unit. Since there can be several special conditions in such big units, the heater has to be designed to accommodate them. Special features can be installed upon request: section with no heat, pressure plates to equalize air flow, buffer sections to space the heater away from other components, etc.

11 Clearance The heaters are for zero clearance to combustible material. This means that there is no distance restrictions between the section of the duct housing the heater and combustible material. However, space should be provided to install and service the duct heater. Please see the minimum recommended installation clearances figures bellow. Minimum recommended distance for safety and service

12 Heaters Components Automatic Reset Thermal Cut-Out An automatic reset, primary safety device. Removes power from elements if overheating occurs. Standard Manual Reset Thermal Cut-Out A secondary safety device which removes power to the elements if over-heating occurs. Standard when required otherwise optional Magnetic Contactor Provides power to the individual stages of the heater. Standard Magnetic Contactor Provides power to the individual stages of the heater. Standard Airflow Switch Safety component used to prevent a heater from operating if there is no airflow. Standard for ON/OFF heaters Solid State Relay (SSR) Proportionally controls the amount of power transmitted to the heating elements. Allows quiet operation and is exceptionally reliable. Standard for proportional heaters

13 Electronic Controller A unique control and safety component. Controls and optimizes the power transmitted to the heating elements according to the duct temperature and air flow. Standard for proportional heaters Disconnect Switch Cuts the power supply to the heater in order to safely perform installation and maintenance tasks. Standard when required by otherwise optional Fuses Protects the total load and/or the individual heater stages. Standard when required by code, otherwise optional Anti-Condensation Heaters To prevent condensation from the terminal enclosure in the humid environment. Standard when required by otherwise optional

14 Field Wiring Note : Prior to installing any wiring, check the unit name plate for main power voltage, control voltage and maximum over current protection. Operating a heater at other than the specified voltage and phase can result in fire or electrical hazard. All field wiring must comply with NATIONAL ELECTRIC CODE and local code requirements. A point-to-point wiring diagram is located on the inside of the control panel door. Use copper conductors only with a minimum of 75 C insulation. Tighten all wiring lugs and terminals prior to connecting power to the unit, as they may loosen during transportation. Connect the power lines to the power distribution terminals inside the control enclosure and tighten to 35 inch-pounds (.4kg meters). If a factory wired disconnect switch is installed, connect the power lines to the line side of the switch. The line block or disconnect is rated at 125% of nominal heater amperes based on 75 C wire. Mount and wire any field installed items as indicated on the factory supplied wiring diagram. When mounting field installed components, do not jumper out or rewire any factory wiring without written approval from Synheat Mfg Pte Ltd only. Violation will void warranty and listing. Energize unit and check all controls for proper operation. Do not operate unit without proper airflow. Electric Heater Preventative Maintenance Checks & Service Schedule Caution! Disconnect All Power Sources Before Attempting To Service Or Clean Heater Before, and at Midpoint of the Heating Season: Check all electrical connections for tightness and broken terminations. Check all wiring for deterioration or over heating. Check unit for dirt or dust, and wipe clean (except elements). Check the element section for obstructions and debris. Check all components for wear and physical damage. Check all safety devices for proper operation. Check temperature controls for proper operation. Caution: In the event of thermal protection failure, it is recommended that a qualified service person investigate the cause of failure prior to returning the heater to normal service. Trouble Shooting Check installation instructions and wiring diagrams to ensure heater is wired and installed properly.

15 Common Symptoms Possible Cause Remedy Heater does not operate No Power Check Disconnect No Control Voltage Check Control Signal (i.e.24 volt) Check Transformer and Transformer Fusing (If Applicable), Replace it if Necessary Blown Fuse Replace Fuse Low or High Temperature Rise Short Cycling Heater W/SSR Does Not Operate Open Limited (Primary or Secondary) Airflow Incorrect Direction Low Airflow Static Pressure Damaged Elements Incompatible Thermostat or Controller Problems with Additional Stages Incorrect CFM Improper Airflow Low CFM Incorrect Signal Applied Interface Board Fuse Blown Replace Limits or Reset As Applicable Check For Continuity Access Limit to Determine if Open, Replace As Necessary Check Sensing Tube, Rotate if Needed Increase Airflow Check For Open or Damaged Elements & Replace As Necessary Check Wiring Check Compatibility Check Location of Thermostat; May be Installed in a Too Hot or Too Cold Location Check Contactors with Open Coil Check For Damaged Elements Check For Block Duct or Location of Heater Check For Even Airflow Across The Face of Element Section Check For Blocked Duct Check For Dirty Filters Check Remedies For Improper Airflow Check Air Velocity Verify Signal Input Replace Fuse

16 Safety Consideration The equipment covered by this manual is designed for safe and reliable operation when installed and operated within its design specification limits. To avoid personal injury or damage to equipment or property while installing or operating this equipment, it is essential that qualified, experienced personnel perform these functions using good judgement and safe practices. See the following cautionary statements. Danger Electrical Shock Hazards. All power must be disconnected prior to installation and serving this equipment. More than one source of power may be present. Disconnect all power sources to avoid electrocution or shock injuries. Hot Parts Hazard. Electric Resistance heating elements must be disconnected prior to servicing. Electric Heaters may start automatically, disconnect all power and control circuits prior to servicing to avoid burns. Warning Check that the unit assembly and component weights can be safely supported by rigging and lifting equipment. All assemblies must be adequately secured during lifting and rigging by temporary supports and restraints until equipment is permanently fastened and set in its final location. All unit temporary and permanent supports must be capable of safely supporting the equipment's weight and any additional live or dead loads that may be encountered. All supports must be designed to meet applicable local codes and ordinances. All fastening devices must be designed to mechanically lock the assembly in place without the capability of loosening or breaking away due to system operation and vibration.

FAN POWERED VAV TERMINALS

FAN POWERED VAV TERMINALS FAN POWERED VAV TERMINALS Models VFR, CFR and CFRQ INSTALLATION, OPERATION AND MAINTENANCE MANUAL All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog data

More information

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTALLATION INSTRUCTIONS Nomenclature: D F I 0 0 H : Open coil element T: Tubular element F: Finned tubular element I: Slip in type F: Flange type 0: No screen left of the heater 1: Screen left of the heater 0: No screen right

More information

( )

( ) (1-800-492-8826) www.wattco.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies two types

More information

(770) wwww.southgateprocess.com

(770) wwww.southgateprocess.com (770) 345-0010 wwww.southgateprocess.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies

More information

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION E L E CT R I C DUCT HEATER FLIPPABLE SHOWN RENEWAIRE ERV + ELECTRIC DUCT HEATER: A SINGLE-SOURCE SOLUTION RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

More information

Installation and Maintenance Manual IM 1102

Installation and Maintenance Manual IM 1102 Installation and Maintenance Manual IM 1102 Parallel Fan Powered Variable Air Volume (VAV) Terminal Box Group: Applied Air Systems Part Number: IM 1102 Date: October 2010 Model MQFVI5 Table of Contents

More information

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FAN POWERED TERMINALS Receiving Inspection Prior to removing the shipping material, visually inspect the packing materials. There

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 55 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 49). A wide

More information

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual 238 Series Industrial/Commercial Electric Unit Heater Owner s Manual This manual covers installation, operation and maintenance. Read carefully before attempting to install, operate or service the 238

More information

Heatrix Electric Duct Heater HXOB Installation Instructions

Heatrix Electric Duct Heater HXOB Installation Instructions Heatrix Electric Duct Heater HXOB Installation Instructions General: Heatrix HXOB Style Electric Duct Heater has been tested and listed for close-coupled application with a forced air system (straight

More information

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters Owner s Manual File E97759 COMFORT S for INDOOR* and OUTDOOR** USE *Excluding Residences ** With Quartz Elements and when mounted Underneath

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

USERS INFORMATION MANUAL

USERS INFORMATION MANUAL USERS INFORMATION MANUAL DOWNFLOW For Installation In: SINGLE AND TWO STAGE 1. Manufactured (Mobile) Home 2. Recreational Vehicle ELECTRIC FURNACE 3. Modular Homes & Buildings 4. Residential Homes MODELS:

More information

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 50 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 50). A wide

More information

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00 I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

FAN POWERED VAV TERMINALS

FAN POWERED VAV TERMINALS FAN POWERED VAV TERMINALS Models VFR, CFR and CFRQ INSTALLATION, OPERATION AND MAINTENANCE MANUAL All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog data

More information

TUTCO Inc. E Series Electric Single Duct VAV / Duct Heater Installation Instructions Heater Models EVH, ERH, EDH & RHE

TUTCO Inc. E Series Electric Single Duct VAV / Duct Heater Installation Instructions Heater Models EVH, ERH, EDH & RHE General for All Models TUTCO Inc. E Series Electric Single Duct VAV / Duct Heater Installation Instructions Heater Models EVH, ERH, EDH & RHE Inspect heater for any possible damage. Check all insulators

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT

More information

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015 Installation and Maintenance Manual IM 1093-1 Single Duct VAV Terminals Group: Controls Part Number: IM 1093 Date: February 2015 Table of Contents Introduction.... 3 Revision History...3 Reference Documents...3

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The

More information

Commercial Duct Heaters. Our products do more in a wide range of applications. Expect More.

Commercial Duct Heaters. Our products do more in a wide range of applications. Expect More. Commercial Duct Heaters Our products do more in a wide range of applications. Expect More. Introduction Indeeco designs and manufactures commercial and industrial electric heating and control systems that

More information

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA) INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA) July 2017 VERSION 1.3 Please read instructions carefully before installation. This NER unit is a packaged fan-less fresh air make-up unit

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER , OPERATION & MAINTENANCE MANUAL ELECTRIC FOR COMMERCIAL INDOOR APPLICATIONS EH SERIES EK SERIES RENEWAIRE.COM ELECTRIC ABOUT RENEWAIRE For over 30 years, RenewAire has been a pioneer in enhancing indoor

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions B2451 & B2452 Series Wall Heaters SPECIFICATIONS MODEL VOLTS HZ AMPS WATTS BTUH B2451 120 60 12.5 1500 5120 B2452 240 60 8.3 2000 6826 208 60 7.2 1500 5120 DIMENSIONS OVERALL Height - 14 1/4 Width - 11

More information

Electric Duct Heaters

Electric Duct Heaters Electric Duct Heaters 12541_Tutco_Catalog.indd 1 3/4/11 8:46:01 AM TYPICAL HEATER CONSTRUCTION TUTCO, the world s largest supplier of open coil heating elements, produces the highest quality products in

More information

B SERIES ELECTRIC FURNACE

B SERIES ELECTRIC FURNACE MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

Installation Instructions

Installation Instructions Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

Bulletin A Brasch Manufacturing Co., Inc.

Bulletin A Brasch Manufacturing Co., Inc. Bulletin A102-1 Brasch Manufacturing Co., Inc. Index Bottom Insert.................... 11 Raintight Construction.............. 11 Bottom Outlet.................... 12 Recessed Terminal Box..............

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL Heated Air Curtains MODELS: INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL E3606-1125HFD, E3609-1125HFD, E3612-1125HFD E3806-1125HFD, E3809-1125HFD, E3812-1125HFD E4206-1125HFD, E4209-1125HFD, E4212-1125HFD

More information

USERS INFORMATION MANUAL

USERS INFORMATION MANUAL MODULAR DX OR CHILLED WATER COOLING WITH ELECTRIC OR HOT WATER HEATING MODELS: US, UM SERIES USERS INFORMATION MANUAL For Installation In: 1. Modular Homes & Buildings 2. Residential Homes LIST OF SECTIONS

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

Series HF custom designed flange and insert heaters.

Series HF custom designed flange and insert heaters. Page 1 - GENERAL INFORMATION A - INTRODUCTION 1 - GENERAL DESCRIPTION A Duct Heater is a self contained heater designed to be installed in the field in an air stream of a duct system, external to the air

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS GENERAL INDEECO Industrial Control Panels are designed to provide years of trouble free operation if properly

More information

Zehnder ComfoInline Heater

Zehnder ComfoInline Heater Zehnder ComfoInline Heater Specifications and Installation Guidelines This unit complies With CSA and UL SDHR5-1.5K120V1P-CIRO17-OTDD-OEMZ standards SDHR6-2.5K220V1P-CIRO17-OTDD-OEMZ SDHR7-3.5K220V1P-CIRO17-OTDD-OEMZ

More information

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available The Neptronic electric heater is manufactured using the most advanced technologies available. Total automation from design to production using integrated CAD/CAM systems not only assures maximum efficiency,

More information

Electric Duct Heaters. IDHB & IDHC Series

Electric Duct Heaters. IDHB & IDHC Series Electric Duct Heaters IDHB & IDHC Series May 2014 1 Duct Heaters Greenheck has a complete line of configurable electric duct heaters that are perfectly suited to your HVAC application. Our CAPS configuration

More information

TABLE OF CONTENTS page 2

TABLE OF CONTENTS page 2 TABLE OF CONTENTS page 2 Metal Sheath Design... page 2 Mechanical Design...... page 3-7 Safety Protection...... page 7 Technical Design Data.....page 7 & 8 Temperature Control Guide...... page 8 Electrical

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS Performance Data AHRI Certification and Performance Notes Model Series 3000 asic Unit AHRI Certification Rating Points VAV: Fiberglass Inlet Size Airflow cfm l/s Min. Inlet Ps w.g. Pa Discharge Sound Power

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the

More information

Visit our web site at

Visit our web site at TABLE OF CONTENTS National Environmental Products ltd. Tel: 1 800 361-2308 Fax:(514) 333-3163 Customer Service Fax: (514) 333-1091 Business hours: from Monday to Friday, 8:00A.M. to 5:00P.M. (North American

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL 216300-000 rev2 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OSE OSX (this page intentionally left blank) IDENTIFYING YOUR SYSTEM IOM216300-000 The HOTSTART

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER September 2017 VERSION 1.5 Please read instructions carefully before installation. This unit is a complete fresh air make-up package with an integrated

More information

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

M1 SERIES DUCT HEATERS

M1 SERIES DUCT HEATERS HEATRIX HEATRIX Electric Duct Heaters may be used with heat pumps, cooling units or any forced air system. Suitable for zero clearance installation with horizontal or vertical air flow. Auto reset primary

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL) INSTALLATION INSTRUCTIONS FOR 8330-5511 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 9330-755 CONTROL BOX KIT (12 VDC HEAT/COOL) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 9530-755 CONTROL

More information

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) Our Expertise, Your Air-Moving Solution ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) PART# 0601710001_rev_A INSTALLATION, OPERATION & MAINTENANCE MANUAL Please read and save these instructions for future reference.

More information

AHU INSTALLATION & OPERATION MANUAL

AHU INSTALLATION & OPERATION MANUAL AHU INSTALLATION & OPERATION MANUAL VERSION 2 AIR HANDLING UNIT MODELS: AHU 500, AHU 900, AHU 1200, AHU 1700, AHU 2000, AHU 2500, AHU3500, AHU 4500, AHU 5000, AHU 6000, AHU 7000, AHU 8000, AHU 10000, AHU

More information

AG Series Electric Heaters

AG Series Electric Heaters AG Series Electric Heaters Installation, Operation and Maintenance Instructions Internal Auxililary Electric Heat 97B0005N03 Table of Contents Overview 3 Vertical Upflow Installation 4 Horizontal Installation

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 8330A751 ZONE CONTROL KIT (12 VDC COOL ONLY) 8530B751

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with

More information

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4 Installation Operation Maintenance Ductable water unit FWD 08-12 - 20-30 - 45 General Information Foreword These installation, operation and maintenance instructions are given as a guide to good practice

More information

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER 1 Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER FOR YOUR SAFETY This manual supplies information on the application,

More information

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

HX150 OPERATOR S MANUAL. 150 kw HEATER

HX150 OPERATOR S MANUAL. 150 kw HEATER HX150 OPERATOR S MANUAL 150 kw HEATER Table of Contents RECEIVING... 3 INSPECTING... 3 LIFTING AND MOVING... 3 SAFETY SYMBOLS... 4 SYMBOL MEANING... 4 SAFETY... 5 DEFINITIONS... 6 POWER AND GROUND CONNECTIONS...

More information

CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH

CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH CONTENTS Page No. Warranty 2 Introduction 3 Rush Program 3 Available Models 3

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PACKAGED HEAT PUMP Table of Contents GENERAL INFORMATION.................. 2 VISUALLY INSPECT PRODUCT............... 2 INTRODUCTION........................... 2 OPTIONAL KITS...........................

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS SIZES FROM 600 CFM TO 9,000 CFM I/O MANUAL Horizontal/Modular/Vertical/Rooftop AHU 2011pg. 1 INTRODUCTION READ THE ENTIRE INSTALLATION, OPERATION

More information

INSTALLATION & MAINTENANCE MANUAL PVI ELECTRIC HOT WATER SUPPLY BOILER

INSTALLATION & MAINTENANCE MANUAL PVI ELECTRIC HOT WATER SUPPLY BOILER INSTALLATION & MAINTENANCE MANUAL PVI ELECTRIC HOT WATER SUPPLY BOILER Installation and service must be performed by a qualified service installer or service agency. IMPORTANT: THIS MANUAL CONTAINS INFORMATION

More information

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A Operating Instructions & Parts Manual EN Silent Low-Profile Ceiling Fans Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A 465933 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72 ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY, 16, 26, 36 & 72 FOR SPLIT-SYSTEM AIR CONDITIONERS 5, 7-1/2, & 15 TONS SPLIT-SYSTEM HEAT PUMPS 7-1/2 & TONS GENERAL This instruction covers the

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5000W Ceiling/Wall Mounted Garage Heater OWNER S MANUAL Model: PH-950N IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

HI Industrial Utility Heater HI Soleus Air International

HI Industrial Utility Heater HI Soleus Air International HI1-50-03 Industrial Utility Heater HI1-50-03 2010 Soleus Air International Thank you for choosing a Soleus Air Utility Heater. This owner s manual will provide you with valuable information necessary

More information

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS WARNING: THIS ACCESSORY IS TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UN- SATISFACTORY OPERATION OR DAMAGE

More information

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY

More information

Industrial Flanged Immersion Heaters

Industrial Flanged Immersion Heaters Industrial Flanged Immersion Heaters Installation, Operation, and Maintenance Instructions 1.0 Handling 1.1 Unpack and handle with care to avoid damage to heater and components. Elements may come in contact

More information

Neptronic Toll Free: TEL: (514) Fax:(514)

Neptronic Toll Free: TEL: (514) Fax:(514) TABLE OF CONTENTS Neptronic Toll Free: 1 800 361-2308 TEL: (514) 333-1433 Fax:(514) 333-3163 Business hours: from Monday to Friday, 8:00A.M. to 5:00P.M. (Eastern time) E-Mail: contact@neptronic.com Introduction...1

More information