TECHNICAL & SERVICE MANUAL

Size: px
Start display at page:

Download "TECHNICAL & SERVICE MANUAL"

Transcription

1 RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. OC0 TECHNICAL & SERVICE MANUAL Series SLZ Ceiling Cassettes R0A Indoor unit [Model names] SLZ-A09AR SLZ-AAR SLZ-A8AR [Service Ref.] SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH This manual does not cover outdoor units. When servicing them, please refer to the service manual.oc0 and this manual in a set. CONTENTS INDOOR UNIT h. PART NAMES AND FUNCTIONS. SPECIFICATIONS. OUTLINES AND DIMENSIONS 5. WIRING DIAGRAM 7 5. REFRIGERANT SYSTEM DIAGRAM 8 6. TROUBLESHOOTING WAY AIR FLOW SYSTEM 6 8. DISASSEMBLY PROCEDURE 8 9. PARTS LIST ON/OFF TOO WARM TOO COOL FAN SELECT AUTO COOL HEAT DRY VANE TIME MODE REMOTE CONTROLLER

2 PART NAMES AND FUNCTIONS Indoor Unit SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH Horizontal Air Outlet Sets airflow horizontal automatically during cooling or dehumidifying. Filter Remove dust and pollutants from inhaled air Grille Auto Air Swing Vane Disperses airflow up and down and adjusts the angle of airflow direction. Air Intake Inhales air from room. Remote controller SET TEMPERATURE button h SET TEMPERATURE button sets and any desired room temperature. ON / OFF button ON/OFF TOO WARM TOO COOL Pushing button starts operation. Pushing again stops operation. AUTO COOL HEAT DRY FAN VANE SELECT TIME TIMER SELECT button Used for selecting timed starting or stopping. MODE MODE SELECT button This button is used to change between auto, cooling, heating and drying operation modes. (SLZ) RESET FAN SPEED button This button is used to set fan speed to low, medium or high. Attention : VANE CONTROL button Used to change the airflow direction. Avoid operation of buttons with fingernails or other sharp objects. Sharp objects may scratch remote controller.

3 SPECIFICATIONS Indoor model SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH Capacity Electrical data Fan motor Dimensions Special remarks Function Power supply Air flow (High/Med./Low) Power outlet Running current Power input Rated frequency Dew prevention heater Power factor Fan motor current Model Winding resistance (at0:) Width Height Depth Weight Air direction Sound level(high/med./low) Fan speed(high/med./low) Fan speed regulator Thermistor RT(at5:) Thermistor RT(at5:) Thermistor RT(at5:) Remote controller model K /h A A W (kw) % A " mm(in) mm(in) mm(in) kg db(a) rpm k" k" k" NOTE : Test conditions are based on ISO 55 Cooling : Indoor D.B. 7: W.B. 9: Outdoor D.B. 5: W.B. : Heating : Indoor D.B. 0: W.B. 5: Outdoor D.B. 7: W.B. 6: Refrigerant piping length (one way): 5m Measured under rated operating frequency. Cooling Heating Single phase 0V, 50Hz 600/50/ PK6V5-LA WHT-BLK : 07 BLK-BLU : 55 BLU-YLW : YLW-BRN : 0 BRN-RED : 65 Cooling Heating Single phase 0V, 50Hz 660/600/ PK6V0-LE WHT-BLK : 8 BLK-BLU : BLU-YLW : 9 YLW-BRN : 6 BRN-RED : UNIT : 570(-7/6) PANEL : 650(5-9/6) UNIT : 08(8-/6) PANEL : 0(/6) UNIT : 570(-7/6) PANEL : 650(5-9/6) UNIT : 6.5 PANEL : 8/5/ 9/7/ 650/580/50 690/60/ MPPC MPPC Cooling Heating Single phase 0V, 50Hz 660/600/ PK6V0-LF WHT-BLK : 7 BLK-BLU : 88 BLU-YLW : 5 YLW-BRN : 5 BRN-RED : 0 0/8/5 70/650/ MPPC Specifications and rating conditions of main electric parts INDOOR UNIT Model Item Indoor fan capacitor (C) Fuse (F) Vane motor (MV) Terminal block (TB) Contactor (5C) Indoor fan motor thermal fuse Cord Heater (H) SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH.5+ 0V 50V.5A MSBPC0 V 50" POWER SUPPLY : P TO OUTDOOR UNIT : P GA-A-E-PS V DC 5:i: 0V AC 5W

4 NOISE CRITERION CURVES SLZ-A09AR.TH NOTCH SPL(dB) Hi 8 Me 5 Lo 90 <50Hz> LINE SLZ-AAR.TH 90 <50Hz> NOTCH Hi Me SPL(dB) 9 7 LINE Lo OCTAVE BAND SOUND PRESSURE LEVEL, db (0 db = µbar) APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NC-70 NC-60 NC-50 NC-0 NC-0 NC-0 OCTAVE BAND SOUND PRESSURE LEVEL, db (0 db = µbar) APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NC-70 NC-60 NC-50 NC-0 NC-0 NC-0 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz SLZ-A8AR.TH <50Hz> NOTCH Hi Me SPL(dB) 0 8 LINE Lo 5 90 OCTAVE BAND SOUND PRESSURE LEVEL, db (0 db = µbar) APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NC-70 NC-60 NC-50 NC-0 NC-0 NC-0 CEILING.5m MICROPHONE UNIT BAND CENTER FREQUENCIES, Hz NOTE: The sound level is measured in an anechoic room where echoes are few, when compressor stops. The sound may be bigger than displayed level under actual installation condition by surrounding echoes. The sound level can be higher by about db than the displayed level during cooling and heating operation.

5 OUTLINES AND DIMENSIONS SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH Wiring entry 8 8 Unit : mm Detail drawing of fresh air intake Fresh air intake Suspension bolt M0 or /8 (procure locally) [6.5mm [9.5mm flared connection flared connection /F /8F SLZ-AAR flared connection /F [6.5mm flared connection /F SLZ-A8AR Refrigerent pipe (gas) Refrigerent pipe (liquid) Refrigerent pipe (gas) Refrigerent pipe (liquid) Models [9.5mm flared connection /8F SLZ-A09AR [6.5mm flared connection /F [00 [.7mm -[.8 hole Burring hole 5 [7. Cut out hole Ceiling surface 5~7 576~60 Ceiling hole 5~7 Drain pipe VP-5 connection (O.D.[) V/M Terminal block Grille Ceiling surface 0 Air outlet hole Grille Drain hole 55 5 (WIRELESS PANEL) Operation lamp V/M Auto vane DEFROST/STAND BY lamp Receiver Air outlet hole 77 Air intake hole Suspension bolt lower edge 8~ ~ ~60 0 Suspension bolt pitch Ceiling hole 650 Emergency operation switch(cooling) Emergency operation switch(heating) V/M V/M Air intake grille Vane motor Air intake hole 5~7 Suspension bolt pitch

6 REMOTE CONTROLLER Unit : mm h ON/OFF TOO WARM TOO COOL 0 AUTO COOL HEAT DRY FAN VANE SELECT TIME MODE RESET B D C A Installation area Area in which the remote controller is not exposed direct sunshine. Area in which there is no nearby heating source. Area in which the remote controller is not exposed to cold (or hot) winds. Area in which the remote controller can be operated easily Area in which the remote controller is beyond the reach of children. Installation method Attach the remote controller holder to the desired location using two tapping screws. Place the lower end of the controller into the holder. A Wireless remote controller (Accessory) B Wall C Remote controller holder (Accessory) D Fixing screw (Accessory) The signal can travel up to approximately 7 meters (in a straight line) within 5 degrees to both right and left of the center line of the receiver. In addition, the signal may not be received if there is interference of light of fluorescent lights or strong sunlight. 6

7 WIRING DIAGRAM SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH CIRCUIT BREAKER TB L w WHT POWER SUPPLY ~/N TB VDC w RED FOR A09/ (: SYSTEM) 0-0V~ w WHT TO OUTDOOR UNIT N CONNECTING w BLU FOR A8 (: SYSTEM) OR MULTI SYSTEM VDC TO OUTDOOR UNIT CONNECTING 0-0V 0V 50Hz 60Hz N N w BLU GRN/YLW GRN/YLW GRILLE DP MF YLW YLW YLW YLW CND(POWER) RED 5 CNC (HEATER) RED CNP(PUMP) BLU X FAN(FAN) WHT 7 WHT BLK X 5 BLU X YLW X FAN(FAN) BRN WHT X5 5 RED ORN C X TRANS DC.V X X X X5 5C w FUSE ZNR I.B CN9 ( PHASE) BLK CN (LIQUID) WHT CN0 (INTAKE) RED CN (DRAIN) WHT CN90 (WIRELESS) 6 WHT 5 CN6V (VANE) GRN 5 6 BLU WHT YLW ORN RED SKY BLU PINK GRY VLT BLU YLW ORN RED BRN RT RT RT DS BLU WHT YLW ORN RED 5 YLW YLW BRN RED ORN YLW BLU VLT GRY PINK H BZ MV MV MV MV CNB LED LED SW SW RU 9 SKY BLU W.B W.R REMOTE CONTROLLER [LEGEND] SYMBOL NAME SYMBOL NAME I.B C FAN MOTOR CAPACITOR FUSE FUSE(.5A) X X-X5 RELAY(D.PUMP /D.HEATER) RELAY (FAN MOTOR) ZNR VARISTOR 5C INDOOR CONTROLLER BOARD COMPRESSOR CONTACTOR W.B BZ WIRELESS REMOTE CONTROLLER BOARD BUZZER LED LED (RUN INDICATOR) LED LED (HOT ADJUST) SWITCH SW (HEATING ON/OFF) SW SWITCH (COOLING ON/OFF) RU RECEVING UNIT SYMBOL DP DS H MF MV RT RT RT TB W.R DRAIN-UP MACHINE DRAIN SENSOR DEW PREVENTION HEATER FAN MOTOR VANE MOTOR ROOM TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR / LIQUID CONDENSER/EVAPORATOR TEMPERATURE THERMISTOR TERMINAL BLOCK WIRELESS REMOTE CONTROLLER How to remove the terminals shown at " w " mark. " w " shows the terminals with a lock mechanism, so they cannot be removed when you pull the lead wire. Be sure to pull the wire by pushing the locking lever (projected part) of the terminal with a finger. locking lever sleeve NOTES:.About the outdoor side electric wiring refer to the outdoor unit electlic wiring diagram for servicing..use copper conductors only. (For field wiring).symbols below indicate. : Terminal block : Connector Slide the sleeve. Pull the wire while pushing the locking lever. The V DC is NOT always against the ground. Terminal has V DC against terminal N. However, between and, these terminals are NOT electrically insulated by the transformer or other device. NAME 7

8 5 REFRIGERANT SYSTEM DIAGRAM SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH Heat exchanger Condenser/evaporator temperature thermistor (RT) Strainer #50 Refrigerant GAS pipe connection (Flare) Refrigerant flow in cooling Refrigerant flow in heating Room temperature thermistor (RT) Pipe temperature thermistor/liquid (RT) Distributor with strainer #50 Strainer #50 Refrigerant LIQUID pipe connection (Flare) 8

9 6 TROUBLESHOOTING 6-. Cautions on troubleshooting () Before troubleshooting, check the followings: Check the power supply voltage. Check the indoor/outdoor connecting wire for mis-wiring. () Take care the followings during servicing. Before servicing the air conditioner, be sure to first turn off the remote controller to stop the main unit, and then turn off the breaker. When removing the indoor controller board, hold the edge of the board with care NOT to apply stress on the components. When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires. 6-. Trouble display Blinking frequency of operation lamp shows the details of trouble of the indoor and the outdoor units. Operation lamp () Incase of being indicated irregularity on the self diagnoses. Blinking frequency blinking Mis-wiring Phenomenon Cause Wiring between the indoor and outdoor is coming off. Countermeasure Check the wiring out between the indoor and outdoor. blinking Indoor-outdoor signal error Pipe temperature thermistor / Liquid. Room temperature thermistor Condenser / evaporator temperature thermistor Drain sensor Difference of wiring polarity between the indoor and outdoor. Trouble of the outdoor inverter P.C. board. Trouble of the Indoor controller board. Mis-connecting of the pipe temperature thermistor / Liquid. Trouble of the pipe temperature thermistor / Liquid. Trouble of the Indoor controller board. Mis-connecting of the room temperature thermistor. Trouble of the room temperature thermistor. Trouble of the Indoor controller board. Mis-connecting of the condenser / evaporator temperature thermistor. Trouble of the condenser / evaporator temperature thermistor. Trouble of the Indoor controller board. Mis-connecting of the indoor drain sensor Trouble of the indoor drain sensor Check the outdoor inverter P.C. board. Refer to the TECHNICAL & SERVICE MANUAL of outdoor unit. Exchange the Indoor controller board. Reinsert the connector (CN). Check the resistance value of the thermistor. Exchange the Indoor controller board. Reinsert the connector (CN0). Check the resistance value of the thermistor. Exchange the Indoor controller board. Reinsert the connector (CN9). Check the resistance value of the thermistor. Exchange the Indoor controller board. Reinsert the connector (CN). Check the resistance value of the thermistor. Trouble of the Indoor controller board. 9 Exchange the Indoor controller board. To be continued on the next page.

10 From the preceding page. Blinking frequency blinking Phenomenon Freezing protection is working. Cause ) Short cycle of air cycle ) Dirty air filter ) Damaged fan ) Abnormal refrigerant Countermeasure ) Clear obstructions from air cycle. ) Clean the air filter ) Check the fan ) Check the refrigerant temperature. 5,7,0 blinking Malfunction of outdoor unit Malfunction of outdoor unit Refer to the TECHNICAL & SERVICE MANUAL of outdoor unit. 6 blinking Outdoor thermistor Mis-connecting of the outdoor thermistor. Reinsert the connector. Trouble of the outdoor thermistor. Check the resistance value of the thermistor. Trouble of the outdoor inverter P.C. board. Exchange the outdoor inverter P.C. board. 9 blinking Malfunction of drain pump ) Malfunction of drain pump ) Damaged drain sensor ) Check the drain pump. ) Check the drain sensor. (Check the drop of water is on.) If the resistance is normal, replace the indoor controller board. () Other case Phenomenon Cause Countermeasure t working of remote controller switch ON/OFF A connector attaching the panel to the body is not connected. Short circuit the protecting parts in the Indoor controller board. Trouble of the Indoor controller board. Connect it. Check the varistor (ZNR) and fuse (FUSE) out in the Indoor controller board. Check the Indoor controller board out. Trouble of the remote controller. Exchange the remote controller. Working the Indoor units and not working the outdoor units. Wiring between the indoor and outdoor is coming off. Difference of wiring polarity between the indoor and outdoor. Trouble of the outdoor inverter P.C. board. Check the wiring out between the indoor and outdoor. Check the outdoor inverter P.C. board. Trouble of the contactor (5C). Exchange the contactor. t rotating the fan in the indoor unit. Malfunction of outdoor unit. Fan motor connector is coming off. Trouble of the Indoor controller board. Trouble of the fan motor. Refer to the TECHNICAL & SERVICE MANUAL of outdoor unit. Check the connector out. Check the fan motor output of the Indoor controller board. Check the resistance value between the each tap of fan motor. Horizontal vane doesn't work. A connector attaching the panel to the body is not connected. Fixing of horizontal vane. Connect it. Check if the connector for vane motor is connected. 0

11 Check of indoor controller board and indoor fan motor Operation lamp blinks once in a fixed period. Error was found in the signal transmitted or received between the indoor and outdoor units. Connection is defective. Is the connecting wire between the indoor and outdoor units connected properly? Remove the devices. Are there any devices emitting noise near the power supply or the connecting wire between the indoor and outdoor units? Turn off the power supply and turn it on again to operate the unit in cooling or heating mode. rmal Operation lamp blinks once in a fixed period. Indoor controller board is defective. Operation lamp blinks twice in a fixed period. Check the condenser/evaporator temperature thermistor. Check the pipe temperature thermistor / liquid. Check the room temperature thermistor. Check the drain sensor thermistor. Is the connector CN9 on the indoor controller board connected? Is the connector CN on the indoor controller board connected? Is the connector CN0 on the indoor controller board connected? Is the connector CN on the indoor controller board connected? Measure the resistance of condenser/evaporator temperature thermistor. Measure the resistance of the pipe temperature thermistor / liquid. Measure the resistance of room temperature thermistor. Measure the resistance of drain sensor. Connection is defective. Connection is defective. Connection is defective. Connection is defective. Is the resistance 0 (short circuit) or (open circuit)? Condenser/evaporator temperature thermistor is defective. Pipe temperature thermistor / liquid is defective. Is the resistance 0 (short circuit) or (open circuit)? Room temperature thermistor is defective. Is the resistance 0 (short circuit) or (open circuit)? Drain sensor is defective. Is the resistance 0 (short circuit) or (open circuit)? Turn off the power supply and turn it on again to operate the unit in cooling mode. rmal Operation lamp blinks twice in a fixed period. Indoor controller board is defective. To be continued on the next page.

12 From the preceding page. The switch of remote controller does not work. Connection is defective. Is the connecting wire between the indoor unit and the decoration panel connected Replace the varistor. Is the varistor on the indoor controller board burnt? Replace the fuse. Is the fuse on the indoor controller board melted? Check the followings. The display on the remote controller does not appear on the screen. The display on the remote controller is dim. The indoor unit does not respond to the remote control signal when the remote controller is not operated near the signal receiving section on the unit. Replace the batteries. Does the display appear on the screen? Does the indoor unit receive the remote control signal when the remote controller is not operated near the signal receiving section on the unit? Replace the remote controller. Indoor controller board is defective. Indoor fan motor does not rotate. Turn off the power supply and check the connectors FAN and on the indoor controller board visually. Connection is defective. Are the connectors FAN and connected? Measure the resistance of connectors FAN and on the indoor controller board. Is the resistance 0 (short circuit) or (open circuit)? Indoor controller board is defective. Indoor fan motor is defective.

13 6-. Test point of indoor controller board Indoor controller board Condenser/evaporator temperature thermistor (RT) Pipe temperature thermistor/liquid (RT) Room temperature thermistor (RT) Drain sensor (DS) 50 Room temperature thermistor (RT) Pipe temperature thermistor/liquid (RT) Condenser/evaporator temperature thermistor (RT) < Thermistor for lower temperature > Power supply input 0-0V AC 0 Fuse 50V AC.5A Resistance (K") Temperature (:)

14 6-. Trouble criterion of main parts SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH Part name Room temperature thermistor (RT) Pipe temperature thermistor/liquid (RT) Condenser/evaporator temperature thermistor (RT) Indoor fan motor (MF) BLK BLU YLW BRN RED ORN WHT P : Thermal fuse 5 ± C P Measure the resistance with a tester. (Part temperature 0 C ~ 0 C) rmal Check method and criterion Measure the resistance between the terminals with a tester. (Coil wiring temperature 0 C ~ 0 C) WHT-BLK BLK-BLU BLU-YLW YLW-BRN BRN-RED.kΩ~9.6kΩ A09AR 86~8 5~58 9~ 8~ 57~7 Abnormal Opened or short-circuited rmal AAR 09~99 07~5 7~5 ~8 99~ A8AR 05~9 85~9 50~5 ~7 89~ Abnormal Opened or short-circuited Vane motor (MV) White Orange Red 5 Blue M Yellow Measure the resistance between the terminals using a tester. (Surrounding temperature 0:~0:) Connector Red Yellow Red Blue Red Orange Red White rmal Abnormal 00" Open or short Drain pump (DP) Yellow Yellow Measure the resistance between the terminals using a tester. (Surrounding temperature 0:~0:) rmal Abnormal 90" Open or short Drain sensor (DS) Measure the resistance between the terminals using a tester. (Surrounding temperature 0:~0:) rmal 0.6k"~6.0k" Abnormal Open or short (Refer to the thermistor)

15 <Thermistor Characteristic graph> Thermistor for lower temperature Room temperature thermistor (RT) Pipe temperature thermistor/liquid (RT) Condenser/evaporator temperature thermistor (RT) 50 < Thermistor for lower temperature > 0 Thermistor R0=5k' ± % Fixed number of B=80K ± % Rt=5exp { 80( 7+t 7 ) } 0: 5k' 0: 9.6k' 0: 6.k' 5: 5.k' 0:.k' 0:.0k' Resistance (K") Temperature (:) Thermistor for drain sensor 0 < Thermistor for drain sensor > Thermistor R0=6.0k' ±5% Fixed number of B=90K ± % Rt=6exp { 90( 7+t 7 ) } 0: 6.0k' 0:.9k' 0:.6k' 5:.k' 0:.8k' 0:.k' Resistance (K") Temperature (:) 5

16 7 -WAY AIR FLOW SYSTEM 7-. Fresh air intake (Location for installation) At the time of installation, use the duct holes (cut out) located at the positions shown in following diagram, as and when required. Fresh air intake Detail drawing of fresh air intake [00 -[.8 hole Burring hole 5 [7. Cut out hole Ceiling surface Refrigerant pipe Electrical Box Drain pipe 7-. Fresh air intake amount & static pressure characteristics SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH Taking air into the unit Static pressure : P [Pa] 50 Air flow : Q [m /min] NOTE: Fresh air intake amount should be 0% or less of whole air amount to prevent dew dripping. How to read curves 0 Curve in the left praphs. Q Q Qa Q Duct characteristics at site B A A E C A D C Q Planned amount of fresh air intake A <m /min> Static pressure loss of fresh air intake duct system with air flow amount Q B <Pa> Forced static pressure at air conditioner inlet with air flow amount Q <Pa> C Static pressure of booster fan with air flow amount Q <Pa> D Static pressure loss increase amount of fresh air intake dust system for air flow amount Q <Pa> E Static pressure of indoor unit with air flow amount Q <Pa> Qa Estimated amount of fresh air intake with out D <m /min> 7-. Interlocking operation method with duct fan (Booster fan) Whenever the indoor unit is operating, the duct fun operates. ()Connect the optional multiple remote controller adapter(pac-sa88ha-e)to the connector CN5 on the indoor controller board. ()Drive the relay after connecting the V DC relay between the Yellow and Orange connector lines. Use a relay under W. MB: Electromagnetic switch power relay for duct fan. X: Auxiliary relay (V DC LY-F) CN5 on indoor unit board CN5 Multiple remote controller adapter PAC-SA88HA-E Package side Multiplr remote controller adapter PAC-SA88HA-E Indoor controller board Be sure to secure insulation material by tape and such 5 Green Yellow Orange MB Connector (5P) Red Brown RC00J590B CN5 C 5C C CND CNC CNP FAN FAN ~ Installation at site Be sure to secure insulation material by tape and such Distance between indoor controller board and relay must be within 0m. 6

17 7-. Fixing of horizontal vane Horizontal vane of each air outlet can be fixed according to the environment, which is installed. Setting procedure ) Turn off a main power supply (Turn off a breaker). ) Disconnect the vane motor connector of the direction of the arrow with pressing the unlocking button as shown in figure below. Electricity insulate the disconnected connector with the vinyl tape. Vane motor Vane motor Connector Unlocking button Horizontal vane ) Set a vertical vane of the air outlet, which tries to fixed by the hand slowly within the range in the table below. Measured standard position of the grille Horizontal vane <Set range> Standard of horizontal position Level 0 (Min.) Downward 5 Downward 55 Downward 70 (Max.) Dimension A (mm) w Dimension between mm and 0 mm can be arbitrarily set. Caution Do not set the dimension out of the range.. Erroneous setting could cause dew drips, smudge on ceiling or malfunction of unit. 7

18 8 DISASSEMBLY PROCEDURE SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH OPERATING PROCEDURE Be careful on removing heavy parts. PHOTOS&ILLUSTRATIONS. Removing the air intake grille () Slide the knob of air intake grille to the direction of the arrow to open the air intake grille. () Remove the hook for secure belt on air inlet grille from the panel. () Slide the shaft in the hinge to the direction of the arrow and remove the air intake grille. Figure Air intake grille Air intake grille knob Grille. Removing the fan guard () Open the air intake grille. () Remove the screws of fan guard. Photo Fan guard Screws Air intake grille. Removing the panel () Remove the air intake grille. (Refer to ) Corner panel (See figure ) () Remove the screw of the corner. () Slide the corner panel to the direction of the arrow, and remove the corner panel. Panel (See photo ) () Disconnect the connector that connects with the unit. () Remove the screws from the panel and loose another screws, which fixed to the oval hole, have different diameter. () Rotate the panel a little to remove the screws.(slide the panel so that the screw comes to a large diameter of the oval hole, which has two different diameters.) Figure Corner panel Photo Connectors Screws Screw Corner panel Panel Screws Panel. Removing the electrical parts () Remove the screws and the control box cover. <Electrical parts in the control box> Indoor controller board (I.B) Compressor contactor (5C) Fuse (FUSE) Varistor (ZNR) Terminal block (TB) Photo Indoor controller board (I.B) Varistor (ZNR) Indoor controller box Compressor contactor (5C) Fuse (FUSE) Terminal blocks (TB) 8

19 OPERATING PROCEDURE PHOTOS&ILLUSTRATIONS 5. Remove the room temperature thermistor (RT) () Remove the panel. (Refer to ) () Pull out the room temperature thermistor from the drain pan. () Remove the screws fixed to the control box cover, and remove the control box cover. () Remove the connector (CN0) from the indoor controller board, and disconnect the room temperature thermistor. Photo Screw Room temperature thermistor (RT) Control box Connectors Drain plug Screw 6. Remove the drain pan () Remove the panel. (Refer to ) () Remove the room temperature thermistor and the lead wires held with fastener; wireless controller board relay connector (9P red) and panel relay connector (0P white). () Remove the screws fixed to the drain pan, and remove the drain pan. () Remove the fan guard. (Refer to ) Screw Fan guard Drain pan Screw 7. Removing the pipe temperature thermistor/liquid (RT) and condenser/evaporator temperature thermistor (RT) () Remove the panel. (Refer to ) () Remove the drain pan. (Refer to 6) () Disconnect the indoor coil thermistor from the holder. () Remove the screws fixed to the piping cover, and remove the piping cover. (See photo 9) (5) Remove the screws fixed to the control box cover, and remove the control box cover. Photo 5 Control box Pipe temperature thermistor/liquid (RT) (6) Remove the connector (CN) from the indoor controller board, and disconnect the pipe temperature thermistor/liquid. Condenser/evaporator temperature thermistor (RT) (6) Remove the connector (CN9) from the indoor controller board, and disconnect the condenser/evaporator temperature thermistor. Pipe temperature thermistor/liquid (RT) Condenser/evaporator temperature thermistor (RT) 8. Remove the fan motor (MF) () Remove the panel. (Refer to ) () Remove the drain pan. (Refer to 6) () Remove the nut and the washer from the turbo fan, and remove the turbo fan. () Remove the screws fixed to the control box cover, and remove the control box cover. (5) Disconnect the connectors of the (fan ) and the (fan ) from the indoor controller board. (6) Remove the screws fixed to the piping cover, and remove the piping cover. (See photo 9) (7) Remove the 6 screws fixed to the flat plate, and remove the flat plate. (8) Disconnect the lead wires to the direction of the fan motor, and remove the nuts of the fan motor. Photo 6 Screws Lead wires Screw Flat plate Nut Screw Nut Fan motor (MF) Nut Screws 9

20 OPERATING PROCEDURE PHOTOS&ILLUSTRATIONS 9. Removing the drain pump (DP) and drain sensor (DS) () Remove the panel. (Refer to ) () Remove the drain pan. (Refer to 6) () Remove the screws fixed to the control box cover, and remove the control box cover. () Remove the connectors of the (CNP) and the (CN) from the indoor controller board. (5) Remove the screw fixed to the cover, and remove the cover. (6) Disconnect the lead wires to the direction of the drain pump.(see photo 7) (7) Remove the screws of the drain pump. (8) Cut the drain hose band, pull out the drain hose from the drain pump. (9) Pull out the drain pump. (0) Remove the drain sensor and the holder. Photo 7 Control box Photo 8 Screw Cover Drain sensor (DS) Lead wires Drain pump (DP) Drain hose Screws Screw Fixing band Control box 0. Removing the heat exchanger () Remove the panel. (Refer to ) () Remove the drain pan. (Refer to 6) () Remove the nut and the washer from the turbo fan, and remove the turbo fan. () Remove the screws fixed to the control box cover, and remove the control box cover. (5) Disconnect the connectors of the (fan ) and the (fan ) from the indoor controller board. (6) Remove the screws fixed to the piping cover, and remove the piping cover. (See photo 9) (7) Remove the pipe temperature thermistor/liquid and condenser/evaporator temperature thermistor. (Refer to 7) (8) Disconnect the lead wires to the direction of the fan motor. (9) Remove the coil support screw, the inside coil screws (See photo 0), and the outside coil screws (See photo 9) from the heat exchanger, and remove the heat exchanger. Photo 9 Coil screws Piping cover Screws of piping cover Lead wires Coil screws Control box Photo 0 Coil screws Coil support Coil support Screw Heat exchanger 0

21 9 PARTS LIST PANEL PARTS SLP-AL Parts. Parts name Specification E AIR OUTLET GRILLE E WIRELSS REMOTE CONTROL BOARD E AUTO VANE E CORNER PANEL 5 E AIR FILTER 6 E INTAKE GRILLE 7 E VANE MOTOR 8 E VANE BUSH 9 E GEAR (V) 0 E GEAR (M) Q'ty/set SLP-AL 8 Remarks (Drawing.) Wiring Diagram Symbol W.B MV Recommended Q'ty Price Unit Amount

22 RESET FUNCTIONAL PARTS SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH ON/OFF AUTO COOL HEAT DRY TOO WARM FAN VANE h TOO COOL SELECT TIME MODE 5

23 . Parts. E BASE Parts name Specification Q'ty/set SLZ- A09 A A8 AR.TH Remarks (Drawing.) Wiring Recommended Diagram Symbol Q'ty Price Unit Amount E07 0 DRUM- E LEG- E07 05 DRUM- E INDOOR HEAT EXCHANGER 5 E07 60 INDOOR HEAT EXCHANGER E07 60 INDOOR HEAT EXCHANGER 6 E MOTOR MOUNT PCS/SET E INDOOR FAN MOTOR PK6V5-LA MF 7 E INDOOR FAN MOTOR PK6V0-LE MF E INDOOR FAN MOTOR PK6V0-LF MF 8 E FLAT PLATE 9 E TURBO FAN 0 E SPL WASHER E DRAIN PAN E ROOM TEMPERATURE THERMISTOR RT E FAN GUARD E DRAIN PLUG E COIL SUPPORT E CONDENSER / EVAPORATOR TEMPERATURE THERMISTOR E PIPE TEMPERATURE THERMISTOR / LIQUID RT RT 8 E DRAIN HOSE 9 E DRAIN SENSOR DS 0 E07 0 SENSOR HOLDER E DRAIN PUMP DP E LEG- E COVER (DRUM) E WIRELESS REMOTE CONTROLLER W.R 5 E REMOTE CONTROLLER HOLDER

24 0-0V 0-0V~ N N POWER SUPPLY TO OUTDOOR UNIT L ELECTRICAL PARTS SLZ-A09AR.TH SLZ-AAR.TH SLZ-A8AR.TH 6 5. Parts. Parts name Specification E COMPRESSOR CONTACTOR Q'ty/set SLZ- A09 A A8 AR.TH Remarks (Drawing.) Wiring Recommended Diagram Symbol Q'ty 5C Price Unit Amount E0 7 8 FUSE 50V.5A FUSE E VARISTOR ZNR E TERMINAL BLOCK P TB 5 E TERMINAL BLOCK P TB E INDOOR CONTROLLER BOARD I.B 6 E07 7 INDOOR CONTROLLER BOARD I.B E07 7 INDOOR CONTROLLER BOARD I.B HEAD OFFICE : MITSUBISHI DENKI BLDG., --, MARUNOUCHI, CHIYODA-KU, TOKYO 00-80, JAPAN CCopyright 00 MITSUBISHI ELECTRIC ENGINEERING CO., LTD. Distributed in Mar. 00.OC0 PDF 8 Made in Japan. New publication, effective Mar. 00. Specifications subject to change without notice.

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes RESET RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SLH/SL Indoor unit [Model names] SLH-AR SLH-.6AR SLH-AR SL-AR SL-.6AR SL-AR Ceiling Cassettes

More information

SERVICE MANUAL. Wireless type Models MS-GA50VB - MS-GA60VB - MS-GA80VB - SPLIT-TYPE, AIR CONDITIONERS. No. OB369 CONTENTS

SERVICE MANUAL. Wireless type Models MS-GA50VB - MS-GA60VB - MS-GA80VB - SPLIT-TYPE, AIR CONDITIONERS. No. OB369 CONTENTS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL Wireless type Models MS-GA50VB - MS-GA60VB - MS-GA80VB - E E E (WH) (WH) (WH). OB69 CONTENTS Indication of model name MS-GA50VB - E MS-GA60VB - E MS-GA80VB -

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

SERVICE MANUAL MSC-GA20VB - (WH) MSC-GA25VB - (WH) MSC-GA35VB - (WH) Wireless type Models

SERVICE MANUAL MSC-GA20VB - (WH) MSC-GA25VB - (WH) MSC-GA35VB - (WH) Wireless type Models SPLIT-TYPE, AIR CONDITIONERS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MSC-GA0VB - (WH) E MSC-GAVB - (WH) E MSC-GAVB - (WH). OB8 Indication of model name MSC-GA0VB -

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

MUH-24RV - MSH-30RV -

MUH-24RV - MSH-30RV - SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models Refer to the Service Manual OB85 REVISED EDITION C when MSH-8RV- E is connected with MXZ-NV- E or MXZ-NV- E as multi system units.

More information

SERVICE MANUAL MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 INDOOR UNIT. No. OBH529. Models

SERVICE MANUAL MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 INDOOR UNIT. No. OBH529. Models SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH529 Models MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 service manual MU-GA VB Series (OB386) MUH-GA VB Series

More information

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models CEILING CASSETTE TYPE, HEAT PUMP AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH483 Ceiling cassette type Models E1 MLZ-KA25VA - E1 MLZ-KA35VA - MLZ-KA50VA - E1 Outdoor unit service manual MXZ-A VA Series

More information

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. SPLIT-TYPE, HEAT PUMP AIR CDITIERS 00 No. OC TECHNICAL & SERVICE MANUAL Series PKFY Wall Mounted R07C R Indoor unit [Model names] PKFY-P0VAM-A [Service Ref.] PKFY-P0VAM-A CTENTS INDOOR UNIT. SAFETY PRECAUTI.

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MSC-A07YV - (WH) E MSC-A09YV - (WH) E MSC-AYV - (WH) HFC utilized R40A. OB39 CONTENTS Indication

More information

SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH SLZ-KF60VA.TH

SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH SLZ-KF60VA.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 205 No. Indoor unit [Model Name] SLZ-KF25VA SLZ-KF35VA SLZ-KF50VA SLZ-KF60VA [Service Ref.] SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH

More information

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS November No. OCH REVISED EDITI-A TECHNICAL & SERVICE MANUAL RA R7C R Indoor unit [Model names] PKFY-PVBM-E PKFY-PVBM-E PKFY-PVBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-E

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

SERVICE MANUAL MFZ-KA25VA - MFZ-KA35VA - MFZ-KA35VA - E1. Wireless type Models FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MFZ-KA25VA - MFZ-KA35VA - MFZ-KA35VA - E1. Wireless type Models FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS. No. FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models MFZ-KAVA - MFZ-KA3VA - E E. OB409 MFZ-KA0VA - E Indication of model name MFZ-KAVA - E MFZ-KA3VA - E MFZ-KA0VA - E NOTE: This service

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 005 SERVICE MANUAL Series PEAD R7C/RA Service ref. Models RP35EA() RP50EA RPEA RP7EA RP00EA() RP5EA RPEA NOTE: This manual describes only service data

More information

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK T AVAILABLE C AMPM AMPM SPLIT-TYPE, HEAT PUM PAIR CDITIERS No. OC REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PLH Indoor unit [Model names] PLH-3AK PLH-3AKH PLH-AKS PLH-AKHS PLH-5AKS PLH-5AKHS PLH-6AKS

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

SERVICE MANUAL MSZ-HC25VA - E1 MSZ-HC35VA - E1 MSZ-HC35VA - E2 MSZ-HC35VAB - E1 MSZ-HC35VAB - E2 INDOOR UNIT. No. OBH466. Models

SERVICE MANUAL MSZ-HC25VA - E1 MSZ-HC35VA - E1 MSZ-HC35VA - E2 MSZ-HC35VAB - E1 MSZ-HC35VAB - E2 INDOOR UNIT. No. OBH466. Models SPLIT-TYPE AIR CONDITIONERS Revision B: MSZ-HC35VA- E2 and MSZ-HC35VAB- E2 have been added. Please void OBH466 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH466 REVISED EDITION-B Models MSZ-HC25VA

More information

PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKH-P60FALH PKH-P71FALH PKH-P100FALH

PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKH-P60FALH PKH-P71FALH PKH-P100FALH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS May 005 No.OC33 SERVICE MANUAL Indoor unit [Model names] PKA-RP60FAL PKA-RP7FAL PKA-RP00FAL [Service Ref.] PKA-RP60FAL PKA-RP7FAL PKA-RP00FAL

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No. SPLIT-TYPE AIR CONDITIONERS Revision E: Detail of the indoor fan speed control in COOL or DRY operation has been added (9-1.3, 9-2.3). Please void OBH515 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL.

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL RA December 22 No. OCH REVISED EDITI-C Indoor unit [Model names] PKFY-PVBM-E PKFY-P2VBM-E PKFY-P2VBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-ER2

More information

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E SPLIT-TYPE AIR CONDITIONERS Revision E: MFZ-KA5VA- E5, MFZ-KA35VA- E5 and MFZ-KA50VA- E5 have been added. Please void OB409 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL. OB409 REVISED EDITION-E Models

More information

SERVICE MANUAL MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB368 R410A CONTENTS

SERVICE MANUAL MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB368 R410A CONTENTS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MUH-GA50VB - E MUH-GA60VB - MUH-GA80VB - E HFC utilized R40A. OB368 CONTENTS Indication of model name MUH-GA50VB - E. TECHNICAL

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

SERVICE MANUAL MSZ-DM25VA - E1, ER1 MSZ-DM35VA - E1, ER1 INDOOR UNIT. No. OBH750. Models

SERVICE MANUAL MSZ-DM25VA - E1, ER1 MSZ-DM35VA - E1, ER1 INDOOR UNIT. No. OBH750. Models INDOOR UNIT SERVICE MANUAL. Models MSZ-DM25VA - E1, ER1 MSZ-DM35VA - E1, ER1 Outdoor unit service manual MUZ-DM VA Series (OBH751) MXZ-DM VA Series (OBH739) MSZ-DM25VA MSZ-DM35VA CONTENTS 1. TECHNICAL

More information

PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E

PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E SPLIT-TYPE, HEAT PUMP AIR CDITIERS July 00 No. OC0 REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PKFY Wall Mounted R0A R0C R [Model names] PKFY-PVGM-E PKFY-P0VGM-E PKFY-P0VGM-E [Service

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

SERVICE MANUAL MS-GF20VA MS-GF25VA MS-GF35VA MS-GF50VA MS-GF60VA MS-GF80VA INDOOR UNIT. No. OBH621 REVISED EDITION-A. Models

SERVICE MANUAL MS-GF20VA MS-GF25VA MS-GF35VA MS-GF50VA MS-GF60VA MS-GF80VA INDOOR UNIT. No. OBH621 REVISED EDITION-A. Models SPLIT-TYPE AIR CONDITIONERS Revision A: MS-GF50VA- E1, MS-GF60VA- E1 and MS-GF80VA- E1 have been added. Please void OBH621. INDOOR UNIT SERVICE MANUAL. OBH621 REVISED EDITION-A Models MS-GF20VA MS-GF25VA

More information

PKA-RP35HAL PKA-RP50HAL

PKA-RP35HAL PKA-RP50HAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS March 2009 No. OCH453 SERVICE MANUAL Indoor unit [Model names] PKA-RP35HAL PKA-RP50HAL [Service Ref.] PKA-RP35HAL PKA-RP50HAL NOTE: This

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1. Wireless type Models HFC FLOOR AND CEILING TYPE AIR CONDITIONERS. No.

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1. Wireless type Models HFC FLOOR AND CEILING TYPE AIR CONDITIONERS. No. FLOOR AND CEILING TYPE AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MUCFH-GA35VB - E MUCFH-GA50VB - MUCFH-GA60VB - E HFC utilized R40A. OB38 CONTENTS Indication of model name MUCFH-GA50VB - E.

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV -

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV - SPLIT-TYPE, AIR CDITIER Revision A: MUX-AWV - E can be connected to MSC-A07/AYV - E. PARTS LIST has partially modified. Please void OB8. SERVICE MANUAL Multi system type Model HFC utilized R40A. OB8 REVISED

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL May 2011 No. OCH452 REVISED EDITION-A Indoor unit [Model names] PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL [Service Ref.] PKA-RP60KAL.TH

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC Revision G: Errors in TROUBLESHOOTING have been corrected. Please void OB455 REVISED EDITION-F. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-G Models MUZ-GB50VA - E1 MUZ-GB50VA

More information

SERVICE MANUAL MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA INDOOR UNIT. No. OBH746 REVISED EDITION-B. Models

SERVICE MANUAL MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA INDOOR UNIT. No. OBH746 REVISED EDITION-B. Models Revision B: 3-1. OPERATING RANGE has been modified. Please void OBH746 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH746 REVISED EDITION-B Models MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA

More information

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -

More information

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH589 Models MSZ-EF22VEW - MSZ-EF22VEW - E1 MSZ-EF25VEW - E1 MSZ-EF22VEB - E1 MSZ-EF35VEW - E1 MSZ-EF22VES E1 - MSZ-EF42VEW - E1 MSZ-EF25VEW - E1

More information

SUZ-A09VR.TH SUZ-A12VR.TH SUZ-A18VR.TH SUZ-A24VR.TH

SUZ-A09VR.TH SUZ-A12VR.TH SUZ-A18VR.TH SUZ-A24VR.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS.OC4 REVISED EDITION-A TECHNICAL & SERVICE MANUAL R40A [model names] SUZ-A09VR SUZ-A2VR SUZ-AVR SUZ-AVR [Service Ref.] SUZ-A09VR.TH SUZ-A2VR.TH SUZ-AVR.TH SUZ-AVR.TH

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL INDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision A: MSZ-SF25/35/42/50VE- E2 and MSZ-SF25/35/ 42/50VE- EN2 have been added. Please void OBH600. INDOOR UNIT SERVICE MANUAL. OBH600 REVISED EDITION-A Models MSZ-SF25VE

More information

SERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC

SERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision A: Resistance of LEV (Expansion valve) has been modified. Power input and others have been added to SPECIFICATION. Method of check of R.V. coil has been

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 9,000BTU / h 11,900BTU / h 17,500BTU

More information

SERVICE MANUAL MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA INDOOR UNIT. No. OBH501. Wireless type Models

SERVICE MANUAL MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA INDOOR UNIT. No. OBH501. Wireless type Models INDOOR UNIT SERVICE MANUAL. OBH501 Wireless type Models MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA CONTENTS Outdoor unit service manual MUZ-D NA Series (OBH502) MUY-D NA Series (OBH502) 1. TECHNICAL CHANGES

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A Revision E: MUZ-GB50VA- E3 has been added. Please void OB455 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-E Wireless type Models MUZ-GB50VA - E1 MUZ-GB50VA -

More information

SERVICE MANUAL PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH. May 2008

SERVICE MANUAL PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH. May 2008 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL May 008 No. OC8 REVISED EDITION-B Indoor unit [Model names] [Service Ref.] PCA-RP0A PCA-RP0A PCA-RP0A# PCA-RP0A PCA-RP0A

More information

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL June 04 No. Indoor unit [Model Name] PLFY-PVCM-E PLFY-P0VCM-E PLFY-PVCM-E PLFY-PVCM-E PLFY-P40VCM-E R40A [Service Ref.] PLFY-PVCM-E.TH PLFY-P0VCM-E.TH

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

AA PLA-RP AA2 PEAD-RP EA PEAD-RP EA2 PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP HA PSA-RP GA

AA PLA-RP AA2 PEAD-RP EA PEAD-RP EA2 PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP HA PSA-RP GA SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL DATA BOOK [Model names] [Model names] PLA-RP AA PLA-RP AA PEAD-RP EA PEAD-RP EA PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit>

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit> SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 4 SERVICE MANUAL Series PEAD R4A Models PEAD-SP7JA(L) PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) NOTE: This manual describes only service data of the indoor

More information

FLOOR CONSOLE / UNDER CEILING DUAL type

FLOOR CONSOLE / UNDER CEILING DUAL type SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision : A MXZ-A5/A7VA- MXZ-A0/A5VA- Please void OB77 E E has been added. has been added. OUTDOOR UNIT SERVICE MANUAL HFC utilized R0A No. OB77 REVISED EDITION-A

More information

SERVICE MANUAL. Wireless type Models MSZ-A09RV - (WH) MUZ-A09RV - MSZ-A12RV - (WH) MUZ-A12RV - E1 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS

SERVICE MANUAL. Wireless type Models MSZ-A09RV - (WH) MUZ-A09RV - MSZ-A12RV - (WH) MUZ-A12RV - E1 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL. OB0 REVISED EDITION-A Wireless type Models E E MSZ-A09RV - (WH) MUZ-A09RV - MSZ-ARV - (WH) MUZ-ARV - E E CONTENTS. TECHNICAL CHANGES. PART NAMES AND

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...

More information

SERVICE MANUAL MUZ-GB50VA - MUZ-GB50VA - E2 OUTDOOR UNIT. No. OB455 REVISED EDITION-D. Wireless type Models HFC

SERVICE MANUAL MUZ-GB50VA - MUZ-GB50VA - E2 OUTDOOR UNIT. No. OB455 REVISED EDITION-D. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision D: RoHS PARTS LIST has been changed. Please void OB455 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB455 REVISED EDITION-D Wireless

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information

PKA-RP35HAL PKA-RP35HALR1 PKA-RP35HALR1-ER PKA-RP50HAL PKA-RP50HALR1 PKA-RP50HALR1-ER

PKA-RP35HAL PKA-RP35HALR1 PKA-RP35HALR1-ER PKA-RP50HAL PKA-RP50HALR1 PKA-RP50HALR1-ER SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL July 2014 No. OCH453 REVISED EDITION-A Indoor unit [Model Name] PKA-RP35HAL PKA-RP50HAL [Service Ref.] PKA-RP35HAL PKA-RP35HALR1

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

SERVICE MANUAL INDOOR UNIT. No. OBH788

SERVICE MANUAL INDOOR UNIT. No. OBH788 INDOOR UNIT SERVICE MANUAL. Models MSZ-AP25VG - E1, EN1 MSZ-AP35VG - E1, EN1 MSZ-AP42VG - E1, EN1 MSZ-AP50VG - E1, EN1 MSZ-AP25VGK - E1, EN1 MSZ-AP35VGK - E1, EN1 MSZ-AP42VGK - E1, EN1 MSZ-AP50VGK - E1,

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL R07C Outdoor unit [model names] No.OC6 REVISED EDITION-B PUH-PVGAA PUH-P.6VGAA PUH-P.6YGAA PUH-PVGAA PUH-PYGAA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA OUTDOOR UNIT. No. OBH543. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA OUTDOOR UNIT. No. OBH543. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 Models MUZ-FE09NA MUZ-FE12NA Indoor unit service manual MSZ-FE NA Series (OBH542) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE INDOOR UNIT. No. OBH623. Models SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE INDOOR UNIT. No. OBH623. Models SPLIT-TYPE AIR CONDITIONERS SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. Models MSZ-FH25VE MSZ-FH35VE - E1 - E1 Outdoor unit service manual MUZ-FH VEHZ Series (OBH625) MUZ-FH VE Series MXZ-D VA Series CONTENTS 1. TECHNICAL

More information

SERVICE MANUAL MUH-GA50VB- MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1 OUTDOOR UNIT. No. OB368 REVISED EDITION-B. Wireless type Models HFC.

SERVICE MANUAL MUH-GA50VB- MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1 OUTDOOR UNIT. No. OB368 REVISED EDITION-B. Wireless type Models HFC. Revision:B - E has been added. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Please void OB68 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB68 REVISED EDITION-B Wireless type Models E -

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information

Installation Instructions

Installation Instructions 0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Inverter-controlled multi system Models E MXZ-A8WV - E MXZ-A6WV - MXZ-AWV - E HFC utilized R40A No. OB9 Indication of model name MXZ-A8WV - E CONTENTS.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

Air Conditioners. Technical Data FBQ-C

Air Conditioners. Technical Data FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor

More information

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1 OUTDOOR UNIT. No. OB381. Models HFC

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1 OUTDOOR UNIT. No. OB381. Models HFC FLOOR AND CEILIN TYPE AIR CONDITIONERS Revision B: The fan guard for MUCFH-A 60VBhas been changed. Please void OB8 REVSED EDITION-A. E OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB8 REVISED EDITION-B

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

MSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9

MSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9 SPLIT-TYPE AIR CONDITIONERS Revision D: MSZ-GE06/09/12/15/18NA- 9 and MSY- GE09/12/15/18NA- 9 have been added. Please void OBH548 REVISED EDITION-C INDOOR UNIT SERVICE MANUAL. OBH548 REVISED EDITION-D

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 SPLIT-TYPE AIR CONDITIONER CONTENTS INSTALLATION MANUAL 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 Model MXZ-A26/32WV HFC utilized R410A 2. INSTALLATION DIAGRAM & ACCESSORIES... 2 3. SELECTING

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

Floor Standing PFFY-P20VKM-E PFFY-P20VKM-ER1 PFFY-P25VKM-E PFFY-P25VKM-ER1 PFFY-P32VKM-E PFFY-P32VKM-ER1 PFFY-P40VKM-E PFFY-P40VKM-ER1

Floor Standing PFFY-P20VKM-E PFFY-P20VKM-ER1 PFFY-P25VKM-E PFFY-P25VKM-ER1 PFFY-P32VKM-E PFFY-P32VKM-ER1 PFFY-P40VKM-E PFFY-P40VKM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL November 008 No. OC0 REVISED EDITI-A Series PFFY Indoor unit [Model names] PFFY-P0VKM-E PFFY-PVKM-E PFFY-PVKM-E PFFY-P0VKM-E Floor Standing

More information

PLFY-P32VAM-E.UK PLFY-P40VAM-E.UK PLFY-P50VAM-E.UK PLFY-P63VAM-E.UK PLFY-P80VAM-E.UK PLFY-P100VAM-E.UK PLFY-P125VAM-E.UK

PLFY-P32VAM-E.UK PLFY-P40VAM-E.UK PLFY-P50VAM-E.UK PLFY-P63VAM-E.UK PLFY-P80VAM-E.UK PLFY-P100VAM-E.UK PLFY-P125VAM-E.UK SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL July No. OC REVISED EDITI-B Indoor unit [Model names] PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E [Service

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information