2 Minus 10 is a high-purity R600a (isobutane), the dominant single-ingredient refrigerant used in state-of-the-art light commercial and domestic refrigeration. HyChill Minus 10 is the natural organic solution for medium temperature refrigeration. Its superior thermodynamic properties make it an ideal refrigerant for use in systems that aim at 6-star Energy Efficiency rating. It is the refrigerant of choice for domestic and light commercial refrigeration units, including fridges and freezers, drink dispensers and stand alone display units. Characteristics - Refrigerant of choice for domestic refrigerators Worldwide - Used by most major OEM in domestic refrigeration applications - Superior energy efficiency - Significantly reduced charge weights Systems - Runs on purpose built R600a systems and compressors - Excellent compatibility with refrigerant oils and lubricants. Available in: HyChill Minus 10 has no ozone depleting potential (ODP) a very low global warming potential (GWP). Cylinders are fitted with a standard refrigeration liquid withdrawal valve. 500g 4.5kg 9kg HyChill Minus 10 does not require an ARC licence

3 The natural solution for refrigeration and air conditioning

4 Minus 30 is a blend of high-purity R600a (isobutane) and R290 (propane), two naturally occurring hydrocarbon refrigerant gases. It is perfect for use in air-conditioning systems and refrigeration applications that traditionally use R12 or R134a. Characteristics - Superior heat rejection better condenser heat exchange performance - Reduced charge weight (only ⅓ of the synthetic refrigerant charge required!) - Operates at lower pressures to R134a - Reduced load on compressor - Less heat at compressor - Less power drain when running - Faster pull down temperature - Lower temperatures at all times Systems - Ideal for use in mobile air conditioning, transport refrigeration and small commercial refrigeration, food display and air-conditioning systems where R12 or R134a have traditionally been used. - Can be used in a R12 or R134a compressor or specific hydrocarbon compressor - Compatible with R12 or R134a heat exchangers & expansion devices and common refrigeration materials and lubricants Available in: A special blend of Minus 30 is available for Extreme Conditions (EC) where ambient temperatures can reach between 50 C and 60 C. Cylinders are fitted with a standard refrigeration liquid withdrawal valve. With UV Dye! 500g 4.5kg 9kg HyChill Minus 30 does not require an ARC licence

5 The natural solution for refrigeration and air conditioning

6 Minus 40 is a high-purity R290 (propane) single ingredient refrigerant used in medium to low temperature refrigeration systems. Ideal for domestic and commercial air conditioning and refrigeration. HyChill Minus 40 is the natural organic solution for air conditioning and medium temperature refrigeration. Its superior thermodynamic properties make it an ideal refrigerant for use in systems that aim at 6-star Energy Efficiency rating. Characteristics - Excellent alternative to R22, R502 or R404a - Superb energy efficiency and cooling performance - Operates at lower pressures than synthetic refrigerants - Significantly reduced charge weight (only 40% of the original charge weight required!) Systems - Can be used in a R502, R22 or R404a compressor and specific R290 compressors - Compatible with existing design heat exchangers and expansion devices and common refrigeration materials and lubricants - Ideal for use in commercial and industrial refrigeration and air-conditioning systems where energy efficiency and consistent performance matter. - Minus 40 (R290) is emerging as the future OEM refrigerant of choice for chillers, cool rooms and hydrocarbon-designed split systems. Available in: Cylinders are fitted with a standard refrigeration liquid withdrawal valve. HyChill Minus 40 does not require an ARC licence 500g 4.5kg 9kg

7 The natural solution for air conditioning and refrigeration

8 Minus 50 is a high-purity blend of R290 propane and R170 ethane. Ideal alternative to synthetic refrigerants (R22, R502, R407c and R404a). HyChill Minus 50 is the natural organic solution for low temperature refrigeration and air-conditioning systems previously charged with CFC, HCFC and HFC refrigerants. An air conditioner or refrigeration system charged with Minus 50 can save up to 30% power compared with synthetic refrigerants. High thermodynamic efficiency of hydrocarbon refrigerant will help cooling a room down in less time, improving the comfort and resulting in substantial energy savings. Characteristics - Superior energy efficiency - Fast cool-down times - Excels in high ambient temperature environment - Operates at lower pressures than synthetic refrigerants Systems - For use in conversions of commercial and industrial refrigeration and air-conditioning systems where R22 and R502 has traditionally been used. - Can be used in R22, R404A or R407C compressors - Compatible with R22, R404A or R407C heat exchangers and expansion devices and common refrigeration materials and lubricants - Switching from synthetic fluorocarbon refrigerants can dramatically reduce power bills and improve the lifespan of the RAC system. Available in: Cylinders are fitted with a standard refrigeration liquid withdrawal valve. HyChill Minus 50 does not require an ARC licence 500g 4.5kg 9kg

9 The natural solution for air conditioning

10 Minus 60 is a high purity blend of R290 propane and R170 ethane, an ideal alternative to synthetic refrigerants (R410A and R32). HyChill Minus 60 is the natural solution for conversion of air-conditioning systems previously charged with synthetic refrigerants Characteristics - Superb performance under high and extreme ambient temperatures - Fast cool-down effect - Superior energy efficiency - Operates at lower pressures than synthetic refrigerants Systems - Switching from synthetic fluorocarbon refrigerants can dramatically reduce power bills and improve the lifespan of the RAC system. - Can be used in a R410A and R32 compressor - Compatible with R410A and R32 heat exchangers and expansion devices and common refrigeration materials and lubricants - Some AC systems may not be suitable for Minus 60 conversions (especially where pressure is used for system control). Available in: Cylinders are fitted with a standard refrigeration liquid withdrawal valve. HyChill Minus 60 does not require an ARC licence 500g 4.5kg 9kg

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

INDUSTRIAL REFRIGERATION. Position on refrigerant selection INDUSTRIAL REFRIGERATION Position on refrigerant selection 1 Which Options door do you choose today? Retrofit HFC 2 Industrial customers What is of vital importance to industrial customers? The reliability

More information

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications: Basic Facts About Hydrocarbons Q. What are hydrocarbons? Hydrocarbon refrigerants are environmentally friendly, non-toxic, non-ozone-depleting replacement for chlorofluorocarbons (CFCs), hydrochlorofluorocarbons

More information

Chapter 2. Alternatives to HCFCs and their Characteristics

Chapter 2. Alternatives to HCFCs and their Characteristics Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid

More information

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Main Anthropogenic Sources of Greenhouse Gases Refrigerants Main Anthropogenic Sources of Greenhouse Gases Refrigerants Content Refrigerant definition Refrigerants Refrigerants as a source of GHG Refrigerant Definition A refrigerant is a substance or mixture, usually

More information

Thermodynamics I. Refrigeration and Heat Pump Cycles

Thermodynamics I. Refrigeration and Heat Pump Cycles Thermodynamics I Refrigeration and Heat Pump Cycles Dr.-Eng. Zayed Al-Hamamre 1 Content Introduction The Reversed Carnot Cycle The Ideal Compression Refrigeration Systems Deviation from the ICRS Selection

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 CFC REFRIGERANTS Since the 1930s, chlorofluorocarbons (CFCs) have been widely used as foam blowing agents, aerosols and especially refrigerants due to their pre-eminent properties

More information

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane. 1/1/12 RS-45 (R434A): Q & A 1 Q: What is RS-44? 1.Q: What is RS-45 A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-45 contain? A: RS-45 is

More information

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration Current use of HFCs and HCFCs. Trends, alternatives and climate impact YEREVAN, Armenia, May 18-19, 2009 Didier COULOMB, Director of the IIR, d.coulomb@iifiir.org Institut du Froid (IIF) - www.iifiir.org

More information

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda Industry co-operation on Natural Refrigerant technology development 2014.02.04 Kenji Matsuda Copyright 2014 JRAIA About JRAIA History The Japan Refrigeration and Air Conditioning Industry Association (JRAIA)

More information

Advantages of R290 (Propane) and other hydrocarbons

Advantages of R290 (Propane) and other hydrocarbons R290 Propane 2017 Why R290 (Propane)? F-Gas regulation 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% HFC refrigerants placement on EU market (% to average 2009-2012) 2015 2016 2017 2018 2019 2020 2021 2022

More information

Alternative Refrigerants Part 1 Future and Current Options. Overview

Alternative Refrigerants Part 1 Future and Current Options. Overview Alternative Refrigerants Part 1 Future and Current Options Dr Michael Bellstedt is the Projects and Technology Officer of the Green Cooling Council (www.greencoolingcouncil.org.au), and the Principal of

More information

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications. TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there

More information

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS Bernard Thonon Greth bernard.thonon@greth.fr Artificial or Natural Refrigerants? Performances COP Capacity Cost Safety Pressure, Temperature

More information

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications: TECHNICAL DATA SHEET Features and uses of is a non-azeotropic blend of HFC with zero Ozone Depletion Potential et low Global Warming Potential (GWP), formulated to meet the requirements of the F-Gas Regulation

More information

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of Daikin s Policy and Comprehensive Actions on the Environmental Impact of Refrigerants Daikin provides homes, businesses and industries worldwide with cooling, heating and refrigeration solutions. We also

More information

The Current Path of Refrigerants

The Current Path of Refrigerants The Current Path of Refrigerants Rick Wentling NA Market Development Manager Opteon Stationary Refrigerants November 9, 2017 Prediction is very difficult; especially if it s about the future. - Neils Bohr

More information

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

Alternatives to HCFC/HFC refrigerants for high ambient temperatures Öko-Recherche Büro für Umweltforschung und -beratung GmbH Alternatives to HCFC/HFC refrigerants for high ambient temperatures Bastian Zeiger Shecco side event 36th OEWG 22.07.2015 Paris, France UNESCO

More information

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants Effect of capillary diameter on the power consumption of VCRS using different refrigerants Dr. A. G. Matani 1, Mukesh K. Agrawal 2 1 Asso. Professor, Mechanical Engineering Department, Govt. College of

More information

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE Paolo VALERO Marek ZGLICZYNSKI Embraco Europe S.r.l. Via Buttigliera 6, 10020 Riva presso Chieri (To), Italy Fax: 0039-011-9437397

More information

Update on Refrigerant Blends

Update on Refrigerant Blends Update on Refrigerant Blends 11 th Annual Financial Agent Workshop The World Bank 26-27 27 March 2007 Steven R. Szymurski Director of Research Air-Conditioning & Refrigeration Institute About ARI www.ari.org

More information

Overview of New Refrigerants and Expected Market Trends

Overview of New Refrigerants and Expected Market Trends OEWG 35, Side Event by EPEE: Open debate on global trends and developments to reduce HFC emissions - an industry perspective Overview of New Refrigerants and Expected Market Trends Presentation by Ray

More information

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-

More information

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice. ECO Energy efficient and environmentally friendly water and space heating SANYO Air Conditioners. The natural choice. CO 2 ECO Water Heater Energy efficient and environmentally friendly water and space

More information

Hydrocarbons as refrigerants

Hydrocarbons as refrigerants Hydrocarbons as refrigerants Hydrocarbons convince with their environment-friendliness and economic feasibility. A developed society cannot function without refrigeration. At home, in food production and

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION 1 CHAPTER 1 INTRODUCTION 1.1 Background The science which deals with creating a controlled climate in indoor space is called air conditioning. Earlier days the air-conditioning was treated as a luxury,

More information

Low GWP alternative refrigerants to R404A

Low GWP alternative refrigerants to R404A HUAYI Statement: Low GWP alternative refrigerants to R404A Live the cooling experience The Company: HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today started out with Spanish and French capital in 1962,

More information

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol Reunión de las Redes de Funcionarios de Ozono de México, Centro América, Sur América y el Caribe de habla hispana Quito, Ecuador, agosto de 2014 Overview of Alternatives and Climate Impact Scenarios Report

More information

ELECTRICAL APPLIANCES

ELECTRICAL APPLIANCES ELECTRICAL APPLIANCES The energy performance of many types of equipment which contribute to building energy use are regulated by MEPS (Minimum Energy Performance Standards) and energy rating labels. These

More information

DuPont ISCEON 9 Series Refrigerants

DuPont ISCEON 9 Series Refrigerants ISCEON 9 Series Refrigerants P R O D U C T I N F O R M A T I O N G U I D E Refrigerants. The Science of Cool. TM de Nemours International S.A. 2 Chemin du Pavillon P.O. Box 50 CH-1218 Le Grand-Saconnex

More information

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment UNEP South America Regional Workshop Low-GWP, Energy-Efficient HCFC Replacement Technologies in the Refrigeration and Air Conditioning Sector Use of hydrocarbon refrigerants in commercial refrigeration

More information

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU Chillers and Refrigerants APPA Institute for Facilities Management Providence, RI September, 2017 1 Purpose of Today s Presentation To provide a broad understanding of chillers and central cooling systems

More information

Scroll Chillers Transition from HCFC-22 to HFCs

Scroll Chillers Transition from HCFC-22 to HFCs Scroll Chillers Transition from HCFC-22 to HFCs An HVAC Manufacturer s Perspective Todd Brown McQuay International Business Development Manager Chillers todd.brown@mcquay.com ICF Workshop, Montreal Canada,

More information

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager Gary Parker Refrigerants Product Manager Refrigerant History Status of the HCFC ( R22) Phase out Ozone Friendly Alternatives Choosing the Best Retrofit Solution Lubricants and how they impact performance

More information

Energy Saving & Eco-Friendly Refrigerant

Energy Saving & Eco-Friendly Refrigerant Technical Seminar Energy Saving & Eco-Friendly Refrigerant Presented By Eva Yim Business Development Director Stephen Cheung Engineering Director Date : Oct 16, 2012 Others 25% Lighting 15% Air Conditioning

More information

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration Alternatives in the AC & Chiller Sectors Sukumar Devotta and Lambert Kuijpers OORG Refrigeration 1 Outline ASHRAE position paper summary which marks a difference in the US approach dealing with various

More information

Possibilities of the RAC sector transformation a technical perspective

Possibilities of the RAC sector transformation a technical perspective A Sustainable transformation of the Refrigeration and Air-conditioning sector Possibilities of the RAC sector transformation a technical perspective The Delegation of the European Union in India and GIZ

More information

March 10, 2016 San Joaquin Valley RETA Meeting

March 10, 2016 San Joaquin Valley RETA Meeting March 10, 2016 San Joaquin Valley RETA Meeting Refrigerant Selection Peter Thomas, P.E., CSP Resource Compliance, Inc. Background and History Simple, dangerous Compounds Safer, more complex refrigerants

More information

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants Mukesh K. Agrawal, Dr. Ashok G. Matani Abstract- The performance of heat transfer is one of the most important research

More information

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT Proceedings of the International Conference on Mechanical Engineering and Renewable Energy 217 (ICMERE217) 18 2 December, 217, Chittagong, Bangladesh ICMERE217-PI-48 IR-REVERSIBILITY ANALYSIS OF A SPLIT

More information

FACT SHEET 6 Transport Refrigeration

FACT SHEET 6 Transport Refrigeration UNEP Ozone Secretariat Fact Sheets on HFCs and Low GWP Alternatives UNEP Ozone Secretariat Background Material on HFC Management October 205 FACT SHEET 6 Transport Refrigeration. Description of market

More information

Oyelami S., Bolaji B. O.

Oyelami S., Bolaji B. O. International Journal of Scientific & Engineering Research, Volume 6, Issue 6, June-2015 1158 Experimental Investigation of the Performance of Liquefied Petroleum Gas (LPG) Refrigerant in A Vapour Compression

More information

Natural Refrigerants.

Natural Refrigerants. Natural Refrigerants www.instituteofrefrigerationireland.ie Seamus Kerr BE, MEngSc, MIEI, MIRI seamus@rslireland.com www.instituteofrefrigerationireland.ie Reminder on terminology: CFC : R12, R502, R11

More information

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH Proceedings of the International Conference on Mechanical Engineering and Renewable Energy 2015 (ICMERE2015) 26 29 November, 2015, Chittagong, Bangladesh ICMERE2015-PI-212 STUDY AND PERFORMANCE ANALYSIS

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures Experimental Study on Performance Parameters for Refrigerants, R41a and R44a at Various Air Outlet Temperatures P. Nagaraju P. G. Student Sanketika Institute of Technology and Management Ch. Kiran Kumar

More information

Chapter 11 REFRIGERATION CYCLES

Chapter 11 REFRIGERATION CYCLES Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008 Chapter 11 REFRIGERATION CYCLES Wan Rosli Wan Sulaiman Copyright The McGraw-Hill Companies, Inc.

More information

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research Update on Next Generation Low GWP Refrigerants for Chillers Products Steve Kujak Director, Next Generation Refrigerant Research The International Symposium on New Refrigerants and Environmental Technology

More information

Guidance for Stationary Refrigeration & Air-Conditioning

Guidance for Stationary Refrigeration & Air-Conditioning Information Sheet RAC 2 - Usage Guidance for Stationary Refrigeration & Air-Conditioning This Information Sheet provides background information about the use of stationary refrigeration, airconditioning

More information

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division Positively Innovative Oct 19 2017 Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations Hitomi ARIMOTO / Product R&D Department, Chemicals Division What is DAIKIN 2 Daikin

More information

Thermodynamics II Chapter 5 Refrigeration

Thermodynamics II Chapter 5 Refrigeration Thermodynamics II Chapter 5 Refrigeration Mohsin Mohd Sies Fakulti Kejuruteraan Mekanikal, Universiti Teknologi Malaysia Objectives Introduce the concepts of refrigerators and heat pumps and the measure

More information

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C McQuay International (A Member of the DAIKIN Group) Hydrofluorocarbon (HFC) refrigerants are critical to the safe and cost-effective phase-out

More information

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Available online at   ScienceDirect. Energy Procedia 109 (2017 ) 56 63 Available online at www.sciencedirect.com ScienceDirect Energy Procedia 109 (2017 ) 56 63 International Conference on Recent Advancement in Air Conditioning and Refrigeration, RAAR 2016, 10-12 November

More information

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL Second Edition STAR DISTRIBUTION CENTRES WORLDWIDE Argentina (to be opened shortly) Australia Bahrain Belgium Brazil

More information

Low GWP Refrigerants for Air Conditioning Applications

Low GWP Refrigerants for Air Conditioning Applications Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Low GWP Refrigerants for Air Conditioning Applications Samuel F. Yana Motta

More information

Chapter 11 REFRIGERATION CYCLES

Chapter 11 REFRIGERATION CYCLES Thermodynamics: An Engineering Approach Seventh Edition in SI Units Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2011 Chapter 11 REFRIGERATION CYCLES Mehmet Kanoglu University of Gaziantep Copyright

More information

HFCs or the Old Refrigerants - what is the best Choice?

HFCs or the Old Refrigerants - what is the best Choice? HFCs or the Old Refrigerants - what is the best Choice? Hermann Halozan Institute of Thermal Engineering, Graz University of Technology Inffeldgasse 25 / B, A-8010 Graz, Austria, Phone: +43 316 873-7303

More information

Global Solutions for Ammonia Industrial Refrigeration

Global Solutions for Ammonia Industrial Refrigeration Global Solutions for Ammonia Industrial Refrigeration MAYEKAWA s lineups and results of Natural Refrigerants Atmosphere 2009 October19th 2009 Mayekawa Mfg. Co., Ltd. Kuniaki Kawamura 1 Founded: 1924 Location:

More information

The Problem of Counterfeit Refrigerants

The Problem of Counterfeit Refrigerants The Problem of Counterfeit Refrigerants James K Carson President, Commission C2, International Institute of Refrigeration Senior Lecturer, School of Engineering, University of Waikato j.carson@waikato.ac.nz

More information

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 68-73 www.iosrjournals.org A Review Paper on Comparative Study of Household- Refrigerator with Alternative

More information

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS Int. J. Chem. Sci.: 14(S2), 2016, 665-674 ISSN 0972-768X www.sadgurupublications.com PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS J. THAVAMANI *, MARRIPUDAGALA KOMALI, SHAIK

More information

Europe. Combine Strong Competitiveness and Reliability. Made in. lightcommercialrefrigeration.danfoss.com

Europe. Combine Strong Competitiveness and Reliability. Made in. lightcommercialrefrigeration.danfoss.com Danfoss Light Commercial Refrigeration Compressors Combine Strong Competitiveness and Reliability D, U, L, P, X, S Ranges Made in Europe lightcommercialrefrigeration.danfoss.com Compressor Ranges D Very

More information

Japanese market and issue of Heat Pump Kenji Matsuda

Japanese market and issue of Heat Pump Kenji Matsuda Japanese market and issue of Heat Pump 2013.11.13 Kenji Matsuda Copyright 2013 JRAIA About JRAIA History The Japan Refrigeration and Air Conditioning Industry Association (JRAIA) was originally established

More information

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer: Information Sheet GEN 5 Refrigerant Quantity General Guidance 1. How much refrigerant is in the system? If you have established that you are using an HFC refrigerant in a refrigeration system, the next

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor(SJIF): 3.134 e-issn(o): 2348-4470 p-issn(p): 2348-6406 International Journal of Advance Engineering and Research Development Volume 02,Issue 06, JUNE -2015 COMPARATIVE

More information

REFRIGERANT REFERENCE GUIDE

REFRIGERANT REFERENCE GUIDE United States National Refrigerats, Inc. 1140 Roosevelt Boulevard Philadelphia, PA 19154 215-698-6620 800-262-0012 Fax: 215-698-7466 United Kingdom National Refrigerants of America Ltd. 4 Watling Close

More information

ON SUBSTANCES THAT DEPLETE

ON SUBSTANCES THAT DEPLETE MONTREAL PROTOCOL ON SUBSTANCES THAT DEPLETE THE OZONE LAYER UNEP 2010 REPORT OF THE REFRIGERATION, AIR CONDITIONING AND HEAT PUMPS TECHNICAL OPTIONS COMMITTEE 2010 Assessment UNEP 2010 REPORT OF THE

More information

TECHNICAL NOTE. Use of R290 refrigerant recommendations. Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment

TECHNICAL NOTE. Use of R290 refrigerant recommendations. Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment TECHNICAL NOTE Use of R290 refrigerant recommendations Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment 1 1. HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today

More information

Evaluation of HCFC Alternative Refrigerants

Evaluation of HCFC Alternative Refrigerants Evaluation of HCFC Alternative Refrigerants Shaobo Jia Global Innovation Heatcraft Worldwide Refrigeration shaobo.jia@heatcraftrpd.com Introduction It is well-known that HCFC refrigerants widely used in

More information

Actions to Control Emission of HFCs in Japan

Actions to Control Emission of HFCs in Japan Actions to Control Emission of HFCs in Japan Implementation of the Act on Rational Use and Proper Management of Fluorocarbons Kazuhiro Sato JRAIA (the Japan refrigeration and Air Conditioning Industry

More information

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry Journal of Physics: Conference Series PAPER OPEN ACCESS Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry To cite this article: IM

More information

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air) FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April

More information

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation Thermodynamic Comparison Using HFO-1234yf and HFO-1234ze in the Refrigeration s and in Applications R. S. Mishra Department of Mechanical Engineering, Delhi Technological University, Delhi, India Article

More information

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA 5 th March 2014 Honeywell $39-39.5B in sales* 54% sales outside U.S. 1,300 sites, 70 countries 132,000 employees Morristown,

More information

Design of LPG Refrigeration System

Design of LPG Refrigeration System Design of LPG Refrigeration System Sethu Sathayan 1, Gopakumar M G 2, Jaya Krishnan S 3, Nanda Gopan 4, Nithin S 6 Assistant Professor, Department of Mechanical Engineering, SNIT Adoor, Kerala, India 1

More information

A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius

A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius To cite this article: R K Dreepaul

More information

Refrigerants and lubricants

Refrigerants and lubricants Refrigerants and lubricants GENERAL INFORMATION When choosing a refrigerant, different aspects must be taken into consideration: Legislation (now and in the future) Safety Application envelope in relation

More information

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading

More information

Refrigerants & Cooling in renovation buildings

Refrigerants & Cooling in renovation buildings Refrigerants & Cooling in renovation buildings 01 Basics Refrigeration circuit. 1 Refrigeration Basics LP HP Mollier Diagram A-C Evaporation B-C Superheat C-D Compression D-E Desuperheat D-G Condensation

More information

Product Offering for 2017

Product Offering for 2017 Product Offering for 2017 Accelera 220 E / 300 E Made in EU (Slovakia) 3.05 & 3.39 EF (COP) from Energy Star respectively Updated electronics Displays temperatures and current tank content in Fahrenheit

More information

Natural refrigerant trends in EU, Japan & North America

Natural refrigerant trends in EU, Japan & North America Natural refrigerant trends in EU, Japan & North America Paris, 17 July 2014 Klara Skacanova, senior analyst shecco Agenda Policy action & market for natural refrigerants: EU Japan North America Europe:

More information

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008 PRICE CHOPPER SARATOGA, NY First cascade supermarket system in North America Installed and Started March of 2008 Why did we choose CO2? Meets Corporate sustainability initiatives Looking for ways to reduce

More information

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration ANALELE UNIVERSITĂłII EFTIMIE MURGU REŞIłA ANUL XXI, NR. 1, 2014, ISSN 1453-7397 Feiza Memet A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

More information

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading

More information

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation Volume 6, Issue 3(201)199-204 ISSN 2347-325 Comparative Performance Evaluation of Vapor Compression Refrigeration System for drop-in Replacement of R22 Vaibhav Jain *, Dhruva Gupta, Himank Gupta, Anirudh

More information

Refrigerant Rule Update

Refrigerant Rule Update Refrigerant Rule Update 2018 Missouri Air Compliance Seminar March 1, 2018 Jennifer Markwardt Senior Consultant jmarkwardt@trinityconsultants.com Agenda Refrigerant phase out or phase down EPA s Significant

More information

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV ECO-FRIENDLY REFRIGERANTS Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV HISTORY OF REFRIGERATION Refrigeration relates to the cooling of air or liquids, thus providing lower temperature to preserve

More information

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER University of Maiduguri Faculty of Engineering Seminar Series Volume 6, december 5 ASSESSMENT OF REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R34A REFRIGERANT IN LARGE CAPACITY FREEZER S. Shodiya*, M.B. Oumarou

More information

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery. HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant

More information

Natural refrigerants - naturally efficient

Natural refrigerants - naturally efficient Natural refrigerants - naturally efficient Operating systems with natural refrigerants for energy efficiency Frankfurt (Main), 10/11/2016. Whether energy transition in Germany or Energy Efficiency Act

More information

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants OEWG40 side-event in Vienna 1 Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants Hideaki Kasahara JRAIA 13 July 2018 Contents 2 0. Who is JRAIA? 1. Timeline of Regulations

More information

Chapter 10. Refrigeration and Heat Pump Systems

Chapter 10. Refrigeration and Heat Pump Systems Chapter 10 Refrigeration and Heat Pump Systems Learning Outcomes Demonstrate understanding of basic vaporcompression refrigeration and heat pump systems. Develop and analyze thermodynamic models of vapor-compression

More information

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a Jignesh Gohel, Dr. Ragesh Kapadia 1 Head, Mechanical Engineering Department, Aditya

More information

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation REI Guide 4a The 2014 EU F-Gas Regulation REI Guide 4a: F-Gas Regulation Guidance Chapters 1. Introduction... 3 2. Summary of Key Features of the new F-Gas Regulation... 4 3. Phase Down of HFC Supply...

More information

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator ISSN:1991-8178 Australian Journal of Basic and Applied Sciences Journal home page: www.ajbasweb.com Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator 1

More information

11/22/2014. (c) DR.A.M.SURENDRA KUMAR

11/22/2014. (c) DR.A.M.SURENDRA KUMAR 11/22/2014 (c) DR.A.M.SURENDRA KUMAR 1 HISTORY A substance capable of absorbing heat from another required substance(space) can be used as Refrigerant. Air was used as refrigerant in olden days in many

More information

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI

More information

Cooling Only & Heat Pump

Cooling Only & Heat Pump Cooling Only & Heat Pump Daikin is renowned for its pioneering approach to product development and the unrivalled quality and versatility of its integrated solutions. From the efficiency of our compressors

More information

Refrigerant & Energy Regulations Update

Refrigerant & Energy Regulations Update Refrigerant & Energy Regulations Update Focus on Refrigeration Applications Rajan Rajendran Emerson Climate Technologies Agenda A Quick History on Refrigerant Progression Environmental Protection Agency

More information

Transitioning to Alternatives and Challenges in Japan

Transitioning to Alternatives and Challenges in Japan SUSTAINABLE TECHNOLOGIES FOR AIR CONDITIONING WORKSHOP INTERNATIONAL CIVIL AVIATION ORGANIZATION MONTREAL, CANADA 1 Transitioning to Alternatives and Challenges in Japan Tetsuji Okada JRAIA 18 November

More information

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation Methods for Improving Thermodynamic Energy and Exergy Performance of Vapour Compression Refrigeration Systems using Thirteen Ecofriendly Refrigerants in Primary Circuit and TIO 2 Nano Particles Mixed with

More information