Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Size: px
Start display at page:

Download "Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4"

Transcription

1 Product catalog Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

2 Features and Benefits Outdoor unit 4TTB Efficiency up to SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy service access and refrigerant connections with full coil protection Fast complete drain, weather proof base Comfort "R" mode approved Glossy corrosion resistant finish Internal high/low pressure and temperature protection 018, 024, 030 ship with start kit Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap High pressure switch R-410A refrigerant S.E.E.T. design testing 100% line run test Low ambient cooling to 55 F as shipped Low ambient cooling to 30 F with AY28X079 Low ambient cooling to 0 F with BAYLOAM103 Extended warranties available Outdoor unit 4TTA3 Climatuff compressor All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant connections with full coil protection DuraTuff base, fast complete drain, weatherproof Comfort R mode approved Glossy corrosion resistant finish Internal compressor high/low pressure and temperature protection Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge and cap R-410A refrigerant Low Pressure Switch High Pressure Switch Compressor Sump Heat S.E.E.T. design testing 100% line run test Low ambient cooling to 55 F as shipped Low ambient cooling to 30 F with AY28X079 Low ambient cooling to 0 F with BAYLOAM103 Indoor convertible air handler GAF Unique Cabinet Design - Double Wall Foamed and Formed Cabinet System - Water Proof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage - Precision Applied Durable Door Seals Multi-Position Upflow/ Horizontal Left / Horizontal Right Front Return Option Braze in Refrigerant Connection Primary/Secondary Condensate Connections Vortica Blower with Integrated Slide Deck for Easy Removal Polarized Plug connections on Blower Aluminum Coil with Integrated Slide Deck for Easy Removal Slide in Electric Heaters Polarized Plug connections for Electric Heater Labeled Panels and connections Guide for 1-1/4" to 1" And 3/4" to 1/2" Conduit connection on Top R-410A Thermal Expansion Valve (TXV) Low Voltage Color Coded Wires Enhanced Coil Fin Patented Blow Through Design PSC 3 Speed Motor Maximum Width of 17.5" Compact 20.8" depth with doors removed Integrated Horizontal Drain pans Single Color Fused 24V Power Optional extended warranty available Indoor convertible air handler GAT Unique Cabinet Design - Double Wall Foamed and Formed Cabinet System - Water Proof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8.2) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage - Precision Applied Durable Door Seals - Tool-free Fasteners on Blower/Filter Door - Modular Cabinet Multi-Position Upflow/ Horizontal Left / Horizontal Right Braze in Refrigerant Connection Primary/Secondary Condensate Connections Premarked Conduit Connection Locations Vortica Blower with Integrated Slide Deck for Easy Removal Polarized Plug connections on Blower Control Protection Pocket Aluminum Coil with Integrated Slide Deck for Easy Removal Slide in Electric Heaters Polarized Plug connections for Electric Heater Labeled Panels and connections 1-1/4" to 1" And 3/4" to 1/2" Conduit connection on Left, Right and Top Molded in 1" Standard Filter rail R-410A Thermal Expansion Valve (TXV) Low Voltage Terminal Connection Point Enhanced Coil Fin Patented Blow Through Design PSC 3 Speed Motor on 3.5 & 4 ton models Constant torque ECM Motor on 5 ton model Maximum Width of 23.5" Compact 20.8" depth with doors removed Integrated Horizontal Drain pans Single Color Fused 24V Power Safety Door Switch 5 year warranty 2013 Trane 2 SSA-PRC009-E4

3 Contents Features and Benefits 2 Nomenclature 4 Unique Cabinet Design Features and Benefits GAF 5 Unique Cabinet Design Features and Benefits GAT 6 General Data 4TTB 7 General Data 4TTA 9 General Data GAF 12 Airflow Data GAF 13 General Data GAT 20 Airflow Data GAT 21 Performance Data 26 Electrical Data GAF 71 Electrical Data GAT 73 Wiring 4TTB 76 Wiring 4TTA 80 Field wiring GAF 85 Field wiring GAT 89 Convertibility GAF / GAT 91 Dimensions 4TTB 92 Dimensions GAF 93 Dimensions GAT 95 Mechanical Specifications Outdoor Units 97 SSA-PRC009-E4 3

4 Nomenclature Outdoor Units 4 T T A A A A Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = /1/60 or /1/60 3 = /3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 4 SSA-PRC009-E4

5 Unique Cabinet Design Features and Benefits GAF 2 Precision Durable Door Seals 1 Unique Cabinet Design 5 Conduit Connection Location r Integrated Horizontal Drain Pans 9 All Aluminum Coil q Thermal Expansion Valve (TXV) 3 Refrigeration Connections 4 Condensate Connections 7 PSC 3 Speed Motor 8 Vortica TM Blower and Deck 0 Labeled Panels and Connections w Maximum width is 17.5 e Compact 20.8 Depth with Doors Removed 1 Unique Cabinet Design - Double wall foamed cabinet system - Waterproof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage 2 Precision Durable Door Seals 3 Brazed Refrigeration Connections 4 Primary/Secondary Condensate Connections 5 Conduit Connection - Conduit Connection on Top 7 PSC 3 Speed Motor 8 Vortica TM Blower and Deck - Polarized Plug on Blower 9 All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil TXV - Patented Enhanced Coil Fin 0 Labeled Panels and Connections q R-410A Thermal Expansion Valve (TXV) w Maximum width is 17.5 e Compact 20.8 Depth with Doors Removed r Integrated Horizontal Drain Pans SSA-PRC009-E4 5

6 Unique Cabinet Design Features and Benefits GAT 1 Unique Cabinet Design 5 Conduit Connections e Integrated Horizontal Drain Pans 2 Precision Durable Door Seals 0 Thermal Expansion Valve (TXV) 3 Refrigeration Connections 8 All Aluminum Coil 4 Condensate Connections r Safety Door Switch 7 Vortica TM Blower and Deck 6 Tool-less Door Fasteners 9 Labeled Panels and Connections w Compact 20.8 Depth with Doors Removed 1 Unique Cabinet Design - Double wall foamed cabinet system - Waterproof Cabinet Design - R-4.2 Insulating Value (Avg Insulating Value R-8.2) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design 2 Precision Durable Door Seals 3 Refrigeration Connections 4 Condensate Connections 5 Premarked Conduit Connection Locations - Conduit Connections on Left, Right, and Top 6 Tool-less Door Fasteners 7 Vortica TM Blower and Deck - Polarized Plug on Blower q Maximum width is All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil EEV - Patented Enhanced Coil Fin 9 Labeled Panels and Connections 0 R-410A Thermal Expansion Valve (TXV) q Maximum width is 23.5 w Compact 20.8 Depth with Doors Removed e Integrated Horizontal Drain Pans r Safety Door Switch - Fused 24V Power t Modular Cabinet 6 SSA-PRC009-E4

7 General Data 4TTB Product Specifications Model No. 1 4TTB3018E1 4TTB3018G1 4TTB3024E1 4TTB3024G1 4TTB3030E1 4TTB3030G1 4TTB3036E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 200/230/1/60 200/230/1/60 208/230/1/60 Min Branch Cir Ampacity Br. Cir. Prot. Rtg. - Max (Amps) Compressor SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL RL Amps - LR Amps Outdoor Fan FL Amps Fan HP 1/8 1/8 1/8 1/8 1/8 1/8 1/8 Fan Dia (inches) Coil Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 4/15-LB/OZ 5/11-LB/OZ 5/8-LB/OZ 5/9-LB/OZ 5/2-LB/OZ 5/11-LB/OZ 5/12-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 5/8 5/8 5/8 3/4 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Charge Spec. Subcooling Dimensions H x W x D (Crated) 34 x 30.1 x x 30.1 x x 30.1 x x 30.1 x x 30.1 x x 30.1 x x 30.1 x 33 Weight - Shipping Weight - Net Start Components YES NO YES NO YES NO NO Sound Enclosure YES NO YES NO NO NO NO Compressor Sump Heat NO NO NO NO NO NO NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT300 BAYCCHT301 BAYCCHT300 BAYCCHT301 BAYCCHT300 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN950 TAYREFLN950 TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7* TAYREFLN7* 1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/ Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db(a)] A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL db [(db(a)] TTB3018E TTB3024E TTB3030E TTB3018G TTB3024G TTB3030G TTB3036E TTB3042D TTB3048D TTB3060D Note: Rated in accordance with AHRI Standard SSA-PRC009-E4 7

8 General Data 4TTB Product Specifications Model No. 1 4TTB3042D1 4TTB3048D1 4TTB3060D1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity Max Fuse Size (Amps) Compressor SCROLL SCROLL SCROLL RL Amps - LR Amps Outdoor Fan FL Amps Fan HP 1/5 1/5 1/5 Fan Dia (inches) Coil Spine Fin Spine Fin Spine Fin Refrigerant R-410A 9/2-LB/OZ 6/13-LB/OZ 8/0-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 7/8 7/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 Charge Spec. Subcooling Dimensions H x W x D (Crated) 34.4 x 35.1 x x 35.1 x x 35.1 x 38.7 Weight - Shipping Weight - Net Start Components NO NO NO Sound Enclosure NO NO NO Compressor Sump Heat NO NO NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3* Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. 8 SSA-PRC009-E4

9 General Data 4TTA Product Specifications Model No. 1 4TTA3030A3 4TTA3030A4 4TTA3036A3 4TTA3036A4 Electrical Data V/Ph/Hz 2 200/230/3/60 460/3/60 200/230/3/60 460/3/60 Min Cir Ampacity Max Fuse Size (Amps) Compressor CLIMATUFF 30a3/30a4 CLIMATUFF 30a3/30a4 CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps Outdoor Fan FL Amps Fan HP 1/8 1/8 1/8 1/8 Fan Dia (inches) Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 5/11-LB/OZ 5/11-LB/OZ 6/07-LB/OZ 6/07-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 3/4 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Charge Spec. Subcooling Dimensions H x W x D (Crated) 38 x 30.1 x x 30.1 x x 30.1 x x 30.1 x 33 Weight - Shipping (lbs.) Weight - Net (lbs.) Start Components NO NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow/Sand Legs - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow/Sand Legs - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 BAY24X045 BAY24X045 Sound Enclosure BAYSDEN001 BAYSDEN001 BAYSDEN003 BAYSDEN003 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001 BAYECMT001 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN2* TAYREFLN2* TAYREFLN7* TAYREFLN7* 1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/ Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For greater lengths and lifts refer to refrigerant piping software Pub# ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db(a)] A-Weighted Sound Power Level [db(a)] A_WEIGHTED FULL OVTAVE SOUND POWER LEVEL db - [db(a)] TTA3030A3/ TTA3036A3/ TTA3042D3/ TTA3048D3/ TTA3060D3/ Note: Rated in accordance with AHRI Stnadard SSA-PRC009-E4 9

10 General Data 4TTA Product Specifications Model No. 1 4TTA3060D3 4TTA3060D4 Electrical Data V/Ph/Hz 2 208/230/3/60 460/3/60 Min Cir Ampacity Max Fuse Size (Amps) Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps Outdoor Fan FL Amps Fan HP 1/5 1/5 Fan Dia (inches) Coil Spine Fin Spine Fin Refrigerant R-410A 8/00-LB/OZ 8/00-LB/OZ Line Size - (in.) O.D. Gas 3 7/8 7/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 Charge Spec. Subcooling Dimensions H x W x D (Crated) 42.4 x 35.1 x x 35.1 x 38.7 Weight - Shipping (lbs.) Weight - Net (lbs.) Start Components NO NO Sound Enclosure NO NO Compressor Sump Heat YES YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 Snow/Sand Legs - Base & Cap 4" High BAYLEGS002 BAYLEGS002 Snow/Sand Legs - 4" Extension BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 Sound Enclosure BAYSDEN004 BAYSDEN004 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 Seacoast Kit BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN3* TAYREFLN3* 1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/ Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For greater lengths and lifts refer to refrigerant piping software Pub# ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. 10 SSA-PRC009-E4

11 General Data 4TTA Product Specifications Model No. 1 4TTA3042D3 4TTA3042D4 4TTA3048D3 4TTA3048D4 Electrical Data V/Ph/Hz 2 208/230/3/60 460/3/60 208/230/3/60 460/3/60 Min Cir Ampacity Max Fuse Size (Amps) Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps Outdoor Fan FL Amps Fan HP 1/5 1/5 1/5 1/5 Fan Dia (inches) Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 6/2-LB/OZ 6/2-LB/OZ 6/13-LB/OZ 6/13-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 3/4 7/8 7/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Charge Spec. Subcooling Dimensions H x W x D (Crated) 34.4 x 35.1 x x 35.1 x x 35.1 x x 35.1 x 38.7 Weight - Shipping (lbs.) Weight - Net (lbs.) Start Components NO NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow/Sand Legs - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow/Sand Legs - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 BAY24X045 BAY24X045 Sound Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001 BAYECMT001 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN7* TAYREFLN3* TAYREFLN3 Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. SSA-PRC009-E4 11

12 General Data GAF MODEL RATED VOLTS/PH/HZ. RATINGS 1 INDOOR COIL Type Rows F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors H.P. Motor Speed RPM Volts/Ph/Hz F.L. Amps - L.R. Amps FILTER Filter Furnished? Type Recommended No.-Size-Thickness REFRIGERANT Ref. Line Connections Coupling or Conn. Size in. Gas Coupling or Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) / Net (Lbs.) GAF2A0A18S11SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 8 1 Direct - 3 See Fan Performance Table 1-1/ /1/ No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x x 17.5 x /107 PRODUCT SPECIFICATIONS GAF2A0A24S21SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 8 1 Direct - 3 See Fan Performance Table 1-1/ /1/ No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x x 17.5 x /110 GAF2A0A30S21SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 8 1 Direct - 3 See Fan Performance Table 1-1/ /1/ No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x x 17.5 x /111 GAF2A0A36S31SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 8 1 Direct - 3 See Fan Performance Table 1-1/ /1/ No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x x 17.5 x /112 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (Ref.: ASTM ) 3 Constant torque Motor 4 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV4248A. 5 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV6060A. 12 SSA-PRC009-E4

13 Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A18 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A18S11SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS N/A N/A N/A N/A 225 N/A N/A 0.9 N/A N/A N/A N/A N/A N/A 1.0 N/A N/A N/A N/A N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A18S11SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 3 BAYECAA08LG1AA Tap 2 Tap 3 BAYECAA10LG1AA Tap 2 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 13

14 Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A24 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A24S21SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS N/A 167 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A24S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 2 BAYECAA08LG1AA Tap 2 Tap 3 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 14 SSA-PRC009-E4

15 Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A24 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A24S21SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS N/A 167 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A24S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 2 BAYECAA08LG1AA Tap 2 Tap 3 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 15

16 Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A30 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A30S21SA Speed Taps VOLTS Speed Taps VOLTS NA NA NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A30S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 2 Tap 2 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 16 SSA-PRC009-E4

17 Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A30 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A30S21SA Speed Taps VOLTS Speed Taps VOLTS NA NA NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A30S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 2 Tap 2 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 17

18 Airflow Data GAF GAF2A0A36 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAF2A0A36S31SA Speed Taps VOLTS Speed Taps VOLTS NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A36S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 1 Tap 1 BAYECAA10LG1AA Tap 1 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 18 SSA-PRC009-E4

19 Airflow Data GAF GAF2A0A36 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAF2A0A36S31SA Speed Taps VOLTS Speed Taps VOLTS NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A36S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 1 Tap 1 BAYECAA10LG1AA Tap 1 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 19

20 General Data GAT MODEL RATED VOLTS/PH/HZ. RATINGS 1 INDOOR COIL Type Rows F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors H.P. Motor Speed RPM Volts/Ph/Hz F.L. Amps - L.R. Amps FILTER Filter Furnished? Type Recommended No.-Size-Thickness REFRIGERANT Ref. Line Connections Coupling or Conn. Size in. Gas Coupling or Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) / Net (Lbs.) GAT2A0B42S31SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 10 1 Direct - 3 See Fan Performance Table 1-1/ /1/ No Throwaway 1-20 X 20-1 in. R-410A Brazed 7/8 3/8 H x W x D 56.8 x 23.5 x x 21.3 x /133 PRODUCT SPECIFICATIONS GAT2A0C48S41SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 10 1 Direct - 3 See Fan Performance Table 1-1/ /1/ No Throwaway 1-20 X 22-1 in. R-410A Brazed 7/8 3/8 H x W x D 58 x 25.5 x x 23.5 x /143 GAT2A0C60S51SA /1/60 See O.D. Specifications Plate Fin /8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 10 1 Direct See Fan Performance Table /1/ n/a No Throwaway 1-20 X 22-1 in. R-410A Brazed 7/8 3/8 H x W x D 62.8 x 25.5 x x 23.5 x /159 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (Ref.: ASTM ) 3 Constant torque Motor 4 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV4248A. 5 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV6060A. 20 SSA-PRC009-E4

21 Airflow Data GAT GAT2A0B42 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAT2A0B42S31SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS N/A N/A N/A 538 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0B42S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 1 Tap 1 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 1 Tap 1 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 1 Tap 1 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 1 Tap 1 BAYEABC15LG3AA Tap 3 Tap 1 BAYEABC20BK1AA Tap 3 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 21

22 Airflow Data GAT GAT2A0B42 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAT2A0B42S31SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS N/A N/A N/A 538 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0B42S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 1 Tap 1 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 1 Tap 1 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 1 Tap 1 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 1 Tap 1 BAYEABC15LG3AA Tap 3 Tap 1 BAYEABC20BK1AA Tap 3 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 22 SSA-PRC009-E4

23 Airflow Data GAT EXTERNAL STATIC (in w.g) GAT2A0C48 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C48S41SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS N/A N/A N/A 1194 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0C48S41SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 1 Tap 1 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 1 Tap 1 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 1 Tap 1 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 2 Tap 1 2 BAYEABC15BK1AA Tap 1 Tap 1 BAYEABC15LG3AA Tap 1 Tap 1 BAYEABC20BK1AA Tap 1 Tap 1 BAYEACC25BK1AA Tap 3 Tap 2 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS 1 Not qualified for 208V 2 Not qualified for 208V in upflow installations Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 23

24 Airflow Data GAT EXTERNAL STATIC (in w.g) GAT2A0C60 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C60S51SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0C60S51SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 2 Tap 2 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 3 Tap 2 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 3 Tap 2 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 4 Tap 3 BAYEABC15LG3AA Tap 1 Tap 1 BAYEABC20BK1AA Tap 4 Tap 3 BAYEACC25BK1AA Tap 5 Tap 4 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #4 for the CTM motor. 24 SSA-PRC009-E4

25 Airflow Data GAT EXTERNAL STATIC (in w.g) GAT2A0C60 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C60S51SA Speed Taps VOLTS AIRFLOW (CFM) Speed Taps VOLTS NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0C60S51SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 2 Tap 2 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 3 Tap 2 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 3 Tap 2 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 4 Tap 3 BAYEABC15LG3AA Tap 1 Tap 1 BAYEABC20BK1AA Tap 4 Tap 3 BAYEACC25BK1AA Tap 5 Tap 4 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #4 for the CTM motor. SSA-PRC009-E4 25

26 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model Indoor model 4TTB3018G1 ARIREF Airflow 600 GAF2A0A18S11+TDR Values At ARI rating conditions Total Net capacity Btuh Airflow 600 CFM Compressor power 1448 watts Indoor fan power 176 watts Outdoor fan power 131 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 26 SSA-PRC009-E4

27 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model 4TTB3018G1 Indoor model GAF2A0A24S21+TDR ARIREF Airflow 600 Values At ARI rating conditions Total Net capacity Btuh Airflow 625 CFM Compressor power 1468 watts Indoor fan power 192 watts Outdoor fan power 131 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions * Dry coil condition (Total capacity = Sensible capacity) Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 27

28 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model Indoor model 4TTB3024G1 ARIREF Airflow 800 GAF2A0A18S11+TDR Values At ARI rating conditions Total Net capacity Btuh Airflow 675 CFM Compressor power 1877 watts Indoor fan power 195 watts Outdoor fan power 128 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= ,15 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 28 SSA-PRC009-E4

29 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model 4TTB3024G1 Indoor model GAF2A0A24S21+TDR ARIREF Airflow 800 Values At ARI rating conditions Total Net capacity Btuh Airflow 750 CFM Compressor power 1917 watts Indoor fan power 228 watts Outdoor fan power 128 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 29

30 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model Indoor model 4TTB3024G1 ARIREF Airflow 800 GAF2A0A30S21+TDR Values At ARI rating conditions Total Net capacity Btuh Airflow 825 CFM Compressor power 1889 watts Indoor fan power 256 watts Outdoor fan power 128 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 30 SSA-PRC009-E4

31 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model 4TTB3030G1 Indoor model GAF2A0A24S21+TDR ARIREF Airflow 1000 Values At ARI rating conditions Total Net capacity Btuh Airflow 900 CFM Compressor power 2244 watts Indoor fan power 287 watts Outdoor fan power 124 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 3/4 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 31

32 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model Indoor model 4TTB3030G1 ARIREF Airflow 1000 GAF2A0A30S21+TDR Values At ARI rating conditions Total Net capacity Btuh Airflow 900 CFM Compressor power 2242 watts Indoor fan power 270 watts Outdoor fan power 124 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 3/4 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 32 SSA-PRC009-E4

33 Performance data Capacities are net in Btuh/ indoor fan heat deducted Outdoor model 4TTB3030E1 Indoor model GAF2A0A36S31+TDR ARIREF Airflow 1000 Values At ARI rating conditions Total Net capacity Btuh Airflow 1025 CFM Compressor power 2328 watts Indoor fan power 363 watts Outdoor fan power 0 watts SEER 13 Correction factors - other airflows Airflow Total capacity Sensible capacity Compressor kw Rated with 25 Feet 3/4 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM kw *** IDDB= *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 33

Hyperion TM Split Systems

Hyperion TM Split Systems Hyperion TM Split Systems Split Systems Air Conditioning (Ducted Type) 3.0-5.0 Tons - R410a - 50Hz Indoor Units GAF2A0A36S3ASA GAT2A0C48S4ASA GAT2A0C60S5ASA GAM2A0C48S4ASB GAM2A0C60S5ASB Outdoor Units

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-14-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 3 5 Tons PUB. NO. 22-1791-16-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB14 4TTB4 1 1 / 2-5 Tons (018E - 061E) PUB. NO. 22-1833-10 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XB14 4TTB4 1 1 /2-5 Tons (018E - 061E) PUB. NO. 22-1833-08 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-06 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-05 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners

More information

AMERICAN STANDARD 14 MODELS 4A7B E

AMERICAN STANDARD 14 MODELS 4A7B E SPLIT SYSTEM COOLING 1 1 / 2 5 ton AMERICAN STANDARD 14 MODELS 4A7B4018-60E PUB. NO. 12-1290-02 June 2009 Features and Benefits DURaTION compressor Efficiency up to 16.0 SEER All aluminum Spine Fin coil

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-13 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-10 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB16 4TTB6 1 1 / 2-5 Tons PUB. NO. 22-1888-01 Features and Benefits Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners QUICK-SESS cabinet, service

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-07 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners

More information

Split System Heat Pump Product & Performance Data

Split System Heat Pump Product & Performance Data SS-PRC007-EN Split System Heat Pump Product & Performance Data XL14i 2TWX4018-060 1½ 5 Tons PUB. NO. 22-1750-05 Features and Benefits Climatuff compressor Efficiency up to 15.25 SEER and 9.6 HSPF All aluminum

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XL 15i 4TWX5018 42A, 049E, 061E 1½ 5 Tons PUB. NO. 22-1800-07 Features and Benefits Climatuff compressor Efficiency up to 16.00 SEER and 9.0 HSPF All aluminum Spine Fin coil

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-03-EN Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XL 15i 4TWX5 1½ 5 Tons PUB. NO. 22-1800-15 Features and Benefits Climatuff compressor Efficiency up to 16.25 SEER and 9.7 HSPF All aluminum Spine Fin coil WeatherGuard II

More information

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A6018-61 PUB. NO. 12-1350-03 February 2015 Features and Benefits DURATION compressor Efficiency up to 17.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Heat Pump A-EN. March 2016 Product Data Split System Heat Pump 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036D1000A 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A Note: Graphics in this document are for representation only.

More information

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A Product Data Split System Heat Pump 4A6H6024H1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. February 2015 12-1202-1B-EN Product Specifications

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling D-EN. August 2016 Product Data Split System Cooling 4A7A6018J1000A 4A7A6024J1000A 4A7A6030J1000A 4A7A6036J1000A 4A7A6042J1000A 4A7A6048J1000A 4A7A6049J1000A 4A7A6060J1000A 4A7A6061J1000A Note: Graphics in this document

More information

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling H-EN. January 2017 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000B 4TTR4025L1000B 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Heat Pump D-EN. February 2016 Product Data Split System Heat Pump 4A6H6018H1000A 4A6H6024H1000A 4A6H6030H1000A 4A6H6036H1000A 4A6H6042H1000A 4A6H6048H1000A 4A6H6060H1000A Note: Graphics in this document are for representation only.

More information

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Cooling E-EN. November 2016 Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N 4TTR3036H1000N 4TTR3042E1000N 4TTR3048E1000N 4TTR3060D1000N November 2016 22-1842-8E-EN Product Specifications Model No. (a)

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A Product Data Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A Note: Graphics in this document are for representation only.

More information

Product Data. Split System Cooling A. November 2013

Product Data. Split System Cooling A. November 2013 Product Data Split System Cooling 4TTR3018G1000A 4TTR3024G1000A 4TTR3030G1000A 4TTR3036E1000A 4TTR3042D1000A 4TTR3048D1000A 4TTR3060D1000A November 2013 22-1842-8A Product Specifications Model No. (a)

More information

Product Data. Split System Heat Pump

Product Data. Split System Heat Pump Product Data Split System Heat Pump 4TWR5018H1000A 4TWR5019H1000A 4TWR5024H1000A 4TWR5030H1000A 4TWR5036H1000A 4TWR5042H1000A 4TWR5048H1000A 4TWR5060H1000A Note: Graphics in this document are for representation

More information

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A7 2014 American Standard Heating & Air Conditioning PUB. NO. 12-1348-02 August 2014 Features and Benefits DURATION 2-stage scroll compressor Efficiency up

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL18i 4TTX8024, 036, 048 & 060 2, 3, 4 & 5 Tons PUB. NO. 22-1885-02 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE

More information

Illusion Split System

Illusion Split System Illusion Split System 50 Hz/R410A Range:1-5 Tons Indoor Units MCDA18DB MCDA24DB MCDA30DB MCDA36DB MCDB42DB MCDB48DB MCDB60DB Outdoor Units 4TTB3018AA 4TTB3024AA 4TTB3030AA 4TTB3036AA 4TTA3030AD 4TTA3036AD

More information

Appendix J Noise Appendix

Appendix J Noise Appendix Appendix J Noise Appendix Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-12 Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet,

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL20i 4TTZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1825-08 Features and Benefits Two CLIMATUFF compressors deliver 50% and

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

Product Data Split System Cooling

Product Data Split System Cooling Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N 4TTR3036H1000N 4TTR3042E1000N 4TTR3043A1000N 4TTR3048E1000N 4TTR3049A1000N 4TTR3060D1000N August 2017 22-1842-8H-EN Outline

More information

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A with AccuLink and Charge Assist PUB. NO. 12-1285-05 December 2009 Features and Benefits Two DURATION compressors deliver

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL20i 4TTZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1825-09 Features and Benefits Two CLIMATUFF compressors deliver 50% and

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data 2TTB0030-060A 2½ 5 Tons 22-1739-04 General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems represent a product that is

More information

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A Product Data Side Discharge AC Models For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after

More information

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers TAM4A0A18S11SA TAM4A0A24S21SA TAM4A0A30S21SA TAM4A0A36S31SA TAM4A0B42S31SA TAM4A0C48S41SA TAM4A0C60S51SA PUB. NO. 22-1848-01 Features and Benefits Air-Tite II TM Cabinet

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers GAM5A0A18M11SA GAM5A0A24M21SA GAM5A0B30M21SA GAM5A0B36M31SA GAM5A0C42M31SA GAM5A0C48M41SA GAM5A0C60M51SA PUB. NO. 22-1845-08 Features and Benefits Unique Cabinet Design

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD

More information

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B Service Facts Air Handler - Convertible Model: Series 2 Air Handlers 3.5-5 ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA GAT2-SF-1B *For use with BAYEA series heaters ONLY WARNING: HAZARDOUS VOLTAGE

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers Black Epoxy Coil GAM5B0A18M11EA GAM5B0A24M21EA GAM5B0B30M21EA GAM5B0B36M31EA GAM5B0C42M31EA GAM5B0C48M41EA GAM5B0C60M51EA Standard Coil GAM5B0A18M11SB GAM5B0A24M21SB

More information

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG: Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG: Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG: Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG: Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install

More information

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG: Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8 Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG: Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN Service Facts Split System Cooling 4TTB3030D1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES Service Facts Split System Cooling 4TTB18E1000A, 4TTB24E1000A 4TTBD1000B, 4TTB36D1000B 4TTB3-SF-1B CAUTION UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION Service Facts Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION 4TTB6-SF-3 UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED.

More information

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8 Service Facts Split System Cooling 4TTR3060D1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and

More information

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ Cooling/Heat Pump Convertible Air Handlers 2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ 5 Ton Preliminary PUB. NO. 22-1777-04 Features and

More information

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 5 Ton Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6024A1000B 4TTR6024A1000B 208/230/1/60 18 20 CLIMATUFF - SCROLL 1-2 208/230/1/60 13.0-52 PROPELLER 27.6-1 DIRECT - 1 3200 1-1/8 835 208/230/1/60 0.74 SPINE FIN 1-24

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6048A1000A 4TTR6048A1000A 208/230/1/60 28 45 CLIMATUFF - SCROLL 1-2 208/230/1/60 21.2-104 PROPELLER 27.6-1 DIRECT - 1 4260 1-1/5 825 208/230/1/60 1.0 SPINE FIN 1-24

More information

Variable Speed Convertible Air Handler 2 1/2 Ton

Variable Speed Convertible Air Handler 2 1/2 Ton Submittal Variable Speed Convertible Air Handler 2 1/2 Ton TEM6A0B30H21S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic.

More information

Variable Speed Convertible Air Handler 4 Ton

Variable Speed Convertible Air Handler 4 Ton Submittal Variable Speed Convertible Air Handler 4 Ton TEM6A0D48H41S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT Service Facts Split System Cooling 4TTR6036B1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

TruComfort Variable Speed Cooling Single Phase 2-5 Tons TruComfort Variable Speed Cooling Single Phase 2-5 Tons Table SC-1-A XV20i R-410A TruComfort Variable Speed Cooling (30 100% capacity) with ComfortLink II1 Uncrated Shipping Line Size (in) Model Power

More information

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT Service Facts Split System Heat Pump 4A6H5042G1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A Service Facts Split System Cooling 3.0 Ton 4A7A6036J1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING Only qualified personnel should

More information

Split System Cooling Product Data XB 1000

Split System Cooling Product Data XB 1000 Split System Cooling Product TTB-D-7 XB 1000 TTB012-060C PUB. NO. 22-1689-02-797 (EN) General Features Split System Cooling Units... Designed With Your Needs In Mind. TTB Split systems represent a new

More information

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/ Service Facts Split System Heat Pump 4TWB4024E1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING Service Facts Convertible Air Handlers Models: Series 5 Air Handlers 1-1/2 to 5 Ton GAM5A0A18M11SA GAM5A0A24M21SA GAM5A0B30M21SA GAM5A0B36M31SA GAM5A0C42M31SA GAM5A0C48M41SA GAM5A0C60M51SA GAM5-SF-1D *For

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed

More information

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES Service Facts Split System Heat Pump 4A6H5049E1000B IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation

More information

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A Product Data 22178001 2/4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ 5 Ton R22/R410A 2/4YCX3018A through 2/4YCX3060A Mar. 03, 2006 2006 American Standard inc. All Rights

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL16i 4TWX6024, 036, 048 & 060E 2, 3, 4 & 5 Tons PUB. NO. 22-1754-17 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER and 9.0 HSPF

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ / YCC30A-SPEC-1D TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING SPECIFICATIONS 2/4YCC30A1096/120A PRODUCT SPECIFICATIONS MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input

More information

4YCC3048A3096A /3/ /

4YCC3048A3096A /3/ / YCC3048A-SPEC-3A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS SPECIFICATIONS 4YCC3048A3075/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ / YCC3048-SPEC-1B TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3048A107/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ / YCC3036A-SPEC-1E TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3036A1064/75/96A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel 65/8 TAG: M4PH4024A1000A SUBMITTAL 2.0 Ton Heat Pump Package Units M4PH4024A1000A Front 2413/16 89/16 23/8 181/2 219/16 52 311/16 1211/16 65/8 Hi./Lo. pressure service port 1/4 SAE 65/8 45/16 19/16 57/8

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Multi-position Air Handler

Multi-position Air Handler Multi-position Air Handler * Note: No internal modifications required for any position. 1 Badge rotation will keep brand in correct position Airflow Refrigerant Connections 1 Refrigerant Connections 1

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG: 4YCC3060A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

4YCC3036A1075B /1/ / YCC3036A1064B /1/ / 4YCC3036A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information