1495D. Installation and Operation Manual, 230 Voltage 2/16/2017
|
|
- Brett May
- 5 years ago
- Views:
Transcription
1 1495D Installation and Operation Manual, 230 Voltage 2/16/2017
2
3 VWR Vacuum Oven 230 Voltage (1495D) Installation and Operation Manual Part Number (Manual): Revision: February 16, 2017 Ü CAN/CSA-C22.2 No : U1: CAN/CSA-C22.2 No :2015 UL :2012/R: UL :2015 EN :2010 EN :2014
4 INTRODUCTION... 5 General Safety Considerations... 5 Engineering Improvements... 6 Contacting Assistance... 6 Recording Data Plate Information... 6 RECEIVING YOUR OVEN... 6 Inspect the Shipment... 7 Orientation Photo... 8 Vacuum Pump... 9 Gaskets... 9 Reference Sensor Device... 9 INSTALLATION Hardwire Requirement Installation Checklist Required Ambient Conditions Environmental Disruptions Power Source Requirements Power Feed Wiring Lifting and Handling Leveling Install the Oven Installation Cleaning Install the Shelving Connect to the Vacuum Supply GRAPHIC SYMBOLS CONTROL PANEL OVERVIEW OPERATION Operating Precautions Theory of Operation Put the Oven into Operation Set the Constant Temperature Set Point Put the Chamber Under Vacuum Set the Over Temperature Limit Heating Profiles USER MAINTENANCE Cleaning and Disinfecting Maintaining Atmospheric Integrity Electrical Components Vacuum Pump Maintenance Calibrate the Temperature display UNIT SPECIFICATIONS Weight Dimensions Capacity Shelf Capacity by Weight Temperature Power REPLACEMENT PARTS... 44
5 GENERAL SAFETY CONSIDERATIONS Note:
6 ENGINEERING IMPROVEMENTS CONTACTING ASSISTANCE RECORDING DATA PLATE INFORMATION Model Number Serial Number
7 INSPECT THE SHIPMENT Guide Profile Programming Included Accessories 3 Shelves 12 Shelf Clips 4 Leveling Feet 1Oil Drain Tray*
8 ORIENTATION PHOTO Figure 1: 1495D
9 VACUUM PUMP GASKETS REFERENCE SENSOR DEVICE
10
11 HARDWIRE REQUIREMENT INSTALLATION CHECKLIST Pre-Installation Install the Oven in a suitable workspace location Set up the Oven for use
12 REQUIRED AMBIENT CONDITIONS ENVIRONMENTAL DISRUPTIONS
13 POWER SOURCE REQUIREMENTS o POWER FEED WIRING
14 LIFTING AND HANDLING LEVELING Note: INSTALL THE OVEN
15 INSTALLATION CLEANING INSTALL THE SHELVING Figure 3: Installing Shelf Clip Figure 2: Shelf Placed on the Clips
16 CONNECT TO THE VACUUM SUPPLY
17 o o o o o o
18
19 Symbol Definition
20
21 Figure 4: Control Panel Power Switch Vacuum Power Switch Over Temperature Limit Thermostat (OTL) Push to Reset
22 Vacuum Gauge
23 Vent Valve o Vacuum Valve
24
25 OPERATING PRECAUTIONS Warning: The oven is not an explosion-proof unit! Avertissement: Ce sont des fours pas résistants aux explosions. Warning Hot Surfaces: These areas are marked with Hot Surface labels. Proper PPE should be employed to minimize risk to burn. Avertissement Surface Chaude: Ces zones sont marqués avec des étiquettes de Surface chaude. Les EPI approprié devraient être employée pour réduire au minimum le risque de brûler.
26 THEORY OF OPERATION
27 Heating Control
28 Note: PUT THE OVEN INTO OPERATION
29 10 Minute Minimum
30 Note: Note: SET THE CONSTANT TEMPERATURE SET POINT
31 PUT THE CHAMBER UNDER VACUUM Vacuum Down
32
33 SET THE OVER TEMPERATURE LIMIT PUSH TO RESET
34 OTL Activation During Normal Operations HEATING PROFILES
35 Warning: Prior to any maintenance or cleaning of this unit, disconnect the power cord from the power supply. Avertissement: Avant d'effectuer toute maintenance ou entretien de cet appareil, débrancher le cordon secteur de la source d'alimentation. CLEANING AND DISINFECTING Cleaning
36 Disinfecting MAINTAINING ATMOSPHERIC INTEGRITY ELECTRICAL COMPONENTS VACUUM PUMP MAINTENANCE
37 CALIBRATE THE TEMPERATURE DISPLAY Note: SET VACUUM
38 Figure 5: Heat Up and Stabilization Phases Oven Chamber Reference Device Reference Device Reference Sensor Reading Oven Temp. Display Offset Value
39
40 Operations Menu
41 Reference Device Reference Device
42 WEIGHT Shipping Net Weight DIMENSIONS Exterior W D H Interior W D H Exterior W D H Interior W D H CAPACITY Cubic Feet Liters SHELF CAPACITY BY WEIGHT Per Shelf Total
43 TEMPERATURE Range Uniformity Stability Heat Up Time to 150 POWER Model AC Voltage Amperage Frequency Phase
44 Description Parts Number
45
Forced Air Ovens 230 Voltage. Installation and Operation Manual SMO14-2, SMO28-2. Previously designated as FX14-2, FX28-2
Forced Air Ovens 230 Voltage Installation and Operation Manual SMO14-2, SMO28-2 Previously designated as FX14-2, FX28-2 SMO Forced Air Ovens 230 Voltage Previously designated FX Forced Air Ovens Installation
More informationVacuum Oven 230 Voltage. Installation and Operation Manual SVAC9-2. Previously designated as VPX9-2
Vacuum Oven 230 Voltage Installation and Operation Manual SVAC9-2 Previously designated as VPX9-2 SVAC9-2 Vacuum Oven 230 Voltage Previously designated VPX9-2 Vacuum Oven Installation and Operation Manual
More informationVacuum Oven 230 Voltage. Installation and Operation Manual SVAC9-2. Previously Designated: VPX9-2
Vacuum Oven 230 Voltage Installation and Operation Manual SVAC9-2 Previously Designated: VPX9-2 SVAC9-2 Vacuum Oven 230 Voltage Installation and Operation Manual Part Number (Manual): 4861570 Revision:
More informationSupplemental Installation & Operation Manual. THE COLDWELL Stainless Steel Cold Trap
Supplemental Installation & Operation Manual THE COLDWELL Stainless Steel Cold Trap For use with Labconco CentriVap cold traps KF25 Connections INTRODUCTION Locations and Applications Range This cold trap
More informationECONOMY GRAVITY OVENS Voltage. Installation - Operation Manual
ECONOMY GRAVITY OVENS 110-120 Voltage Installation - Operation Manual SGO1E SGO6E 2 P age SGO Economy Gravity Ovens 110-120 Voltage Part Number (Manual): 4861566 Revision: December 5, 2017 Pictured on
More informationFOV Series Forced Air Ovens Installation - Operation Manual
FOV Series Forced Air Ovens Installation - Operation Manual TestEquity LLC 6100 Condor Drive Moorpark, CA 93021 Support: 877-512-3457, 805-480-0638 Corporate: 800-732-3457, 805-498-9933 http://www.testequity.com
More informationClean Room Oven Voltage. Installation and Operation Manual SMO5CR-2. Previously designated as CR1-2
Clean Room Oven 220 240 Voltage Installation and Operation Manual SMO5CR-2 Previously designated as CR1-2 SHEL LAB Clean Room Oven 220-240 Voltage Installation and Operation Manual Part Number (Manual):
More informationSMO FORCED AIR OVENS 230 Voltage. Installation - Operation Manual SMO14-2 SMO28-2 SMO28G-2
SMO FORCED AIR OVENS 230 Voltage Installation - Operation Manual SMO14-2 SMO28-2 SMO28G-2 These ovens require permanent connect wiring (also known as a hardwiring) to a power source Pictured on Cover:
More informationBOD INCUBATORS MODELS: LI6P/LI6P-2 LI20P/LI20P-2 Installation and Operations Manual /12
BOD INCUBATORS MODELS: LI6P/LI6P-2 LI20P/LI20P-2 Installation and Operations Manual 861666-1 05/12 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationINSTALLATION AND OPERATION MANUAL
ECONOMY OVENS SMO1E SMO3E MODELS OBSOLETED AFTER MAY 31ST SMO1E-2, SMO3E-2, SMO5E, SOM5E-2 INSTALLATION AND OPERATION MANUAL Revised June 13, 2017 861659 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius,
More informationBEAD BATH. MODELS: , , & , , & V/ V Models INSTALLATION AND OPERATION MANUAL
BEAD BATH MODELS: 74300-706, 74300-714, & 74300-720 74200-706, 74200-714, & 74200-720 100-120V/220-240V Models MICROPROCESSOR CONTROLLED INSTALLATION AND OPERATION MANUAL 4861685-1 03/12 These units are
More informationClean Room Oven Voltage. Installation and Operation Manual SMO5CR-2
Clean Room Oven 220 240 Voltage Installation and Operation Manual SMO5CR-2 2 P age SHEL LAB Clean Room Oven 220-240 Voltage Installation and Operation Manual Part Number (Manual): 4861580 Revision: November
More informationVACUUM OVENS Volts. Installation - Operation Manual SVAC1-2 SVAC2-2 SVAC4-2
VACUUM OVENS 220 240 Volts Installation - Operation Manual SVAC1-2 SVAC2-2 SVAC4-2 Pictured on cover left to right: SVAC1-2, SVAC2-2, SVAC4-2 The oven requires either a NEMA 6-15P electrical power outlet
More informationMODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL
ECONOMY VACUUM OVEN MODEL: 1407, 1407-2, 1408, & 1408-2 INSTALLATION AND INSTRUCTION MANUAL Sheldon Manufacturing Inc. P.O. Box 627, Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationVACUUM OVEN MODEL: 1425, , , /
VACUUM OVEN MODEL: 425, 425-2 445, 445-2 465, 465-2 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 973 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationVacuum Purge Ovens CVO-10. Installation - Operation Manual
Vacuum Purge Ovens CVO-5 CVO-5-2 CVO-10 Installation - Operation Manual Vacuum Purge Ovens CVO-5: 110 120 Voltage North America CVO-5-2, CVO-10: 220 240 Voltage Part Number (Manual): 4861790 Revision:
More informationVACUUM OVEN. Model: VPX9-2. Installation and Operation Manual
VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897
More informationVACUUM OVEN SVAC1 SVAC1-2 SVAC2 SVAC2-2 SVAC4 SVAC4-2 Previously designated as 1425, , ,
VACUUM OVEN SVAC SVAC-2 SVAC2 SVAC2-2 SVAC4 SVAC4-2 Previously designated as 425, 425-2 445, 445-2 465, 465-2 INSTALLATION AND OPERATION MANUAL Revised 3 / 206 48653 Sheldon Manufacturing Inc. P.O. Box
More informationVACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL
VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationSMI INCUBATORS Voltage. Installation - Operation Manual
SMI INCUBATORS 110 120 Voltage Installation - Operation Manual SMI31 SMI39 Pictured on Cover: SMI31 left, SMI39 right Manufacturing Warranty For information on your warranty and online warranty registration
More informationSMI INCUBATORS Voltage. Installation - Operation Manual SMI2 SMI6 SMI7 SMI11 SMI12
SMI INCUBATORS 100 120 Voltage Installation - Operation Manual SMI2 SMI6 SMI7 SMI11 SMI12 Pictured on cover: SMI6 SMI11 SMI12 (2 Stacked SMI6s) SMI2 SMI7 2 P age SMI General Purpose Incubators 100 120
More informationWATER BATHS. MODELS: SWBC22 and SWBC22-2 MICROPROCESSOR CONTROLLED INSTALLATION AND OPERATION MANUAL 12/
WATER BATHS MODELS: SWBC22 and SWBC22-2 Previously designated as WPC65 & WPC65-2 MICROPROCESSOR CONTROLLED INSTALLATION AND OPERATION MANUAL 12/2013 4861565 These units are TUV CUE listed as water baths
More informationBOD INCUBATOR Voltage. Installation - Operation Manual SRI20-2
BOD INCUBATOR 220-240 Voltage Installation - Operation Manual SRI20-2 2 P age SRI20-2 BOD Incubator 220-240 Voltage Installation and Operation Manual Part Number (Manual): 4861787 Revision: November 10,
More informationNarrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC
Commercial Refrigerator And Freezer User s Manual Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC 10/2016
More informationINCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL
INCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL These units are UL listed general purpose air incubators for professional, industrial or educational
More informationWATER BATHS MODELS: WPC95 & WPC95-2 INSTALLATION AND OPERATION MANUAL /12 MICROPROCESSOR CONTROLLED
WATER BATHS MODELS: WPC95 & WPC95-2 MICROPROCESSOR CONTROLLED INSTALLATION AND OPERATION MANUAL 4861564 08/12 These units are TUV CUE listed as general purpose air incubators for professional, industrial
More informationVACUUM OVENS MODEL: , , INSTALLATION AND OPERATIONAL MANUAL
VACUUM OVENS MODEL: 05012-80, 05012-85 05012-90, 05012-95 INSTALLATION AND OPERATIONAL MANUAL COLE-PARMER INSTRUMENT COMPANY 625 East Bunker Court, Vernon Hills, IL 60061 (847) 549-7600 FAX (847) 549-7676
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70067850 Date Issued: July 28, 2017 Issued to: Otis Instruments, Incorporated 301 S. Texas Ave. Bryan, Texas, 77803 USA Attention: Nicholas Sandera The products listed
More informationTTT Digital Incubator
TTT Digital Incubator 135000 135000-2 Operating Instructions N2400342 Rev. 1 08/13 Table of Contents 1.0 Safety... 3 2.0 Intended Use of Product... 4 3.0 Installation... 4 3.1 Unpacking the Unit... 4 3.2
More informationECONOMY OVENS MODELS: 1310, 1320, 1321F, 1324, 1325F, 1326, 1327F INSTALLATION AND OPERATION MANUAL
ECONOMY OVENS MODELS: 1310, 1320, 1321F, 1324, 1325F, 1326, 1327F INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationFLY INCUBATORS Voltage. Installation - Operation Manual SRI6PF-2 SRI20PF-2
FLY INCUBATORS 220-240 Voltage Installation - Operation Manual SRI6PF-2 SRI20PF-2 For Fly Cultivation This unit is designed for the growth, cultivation, incubation, and storage of fruit flies (Drosophila
More informationGlass Doors, Hinged Bottom Mounts
Product Specification Sheets Construction Standard Features Interior and exterior constructed of heavyduty white coated steel CFC free foamed-in-place polyurethane insulation Stainless steel floor Externally
More informationInstruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid
Instruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance
More informationHORIZONTAL AIR FLOW CLEAN ROOM OVEN
HORIZONTAL AIR FLOW CLEAN ROOM OVEN MODEL: CR1-2 INSTALLATION AND OPERATIONAL MANUAL P.O. Box 627 300 N. 26 th Avenue Cornelius, Oregon 97113 EMAIL:tech @ Shellab.com INTERNET: http://www.shellab.com 1-800-322-4897
More informationOperating Instruction Manual
COMMERCIAL ELECTRIC CONVECTION OVEN Operating Instruction Manual ECO-500 ECO-250 Model Voltage Power Amperage Dimensions Width Depth Height ECO-250 1440W 12A 18.75" 19-7/8" 15" 120V ~ 60Hz ECO-500 1600W
More informationOperating Instruction Manual
COMMERCIAL COUNTERTOP PIZZA OVEN Operating Instruction Manual EPO-1 Model Voltage Power Amperage Dimensions Width Depth Height EPO-1 120V ~ 60Hz 1500W 12.5A 20.86" 14.76" 9.25" BEFORE OPERATING ANY EQUIPMENT,
More information200i User s information manual
M2i-UM-1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Cast iron condensing boiler 200i User
More informationINSTALLATION AND OPERATION MANUAL
MICROPROCESSOR CONTROLLED OVEN MODELS: CE3F & CE5F 11/11 4861579 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationUser Manual. Glass Countertop Mechandiser Refrigerator. Single Door Model: 360GSM3HCB, 360GSM3HCW Pass-Through Model: 360GSM32HCB, 360GSM32HCW
Glass Countertop Mechandiser Refrigerator Single Door Model: 360GSM3HCB, 360GSM3HCW Pass-Through Model: 360GSM32HCB, 360GSM32HCW 12/2017 Please read the manual thoroughly prior to equipment set-up, operation
More informationInstallation Instructions
Installation Instructions 42" Island Vent Hood ZV1050 monogram.com 1 Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for local inspector s
More informationUSER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model
USER MANUAL Read manual thoroughly prior to equipment set-up, operation or maintenance. Model 243009 Model 243010 NEXEL 1-Door Reach-in Freezer NEXEL 2-Door Reach-in Freezer For questions, please contact
More informationUSER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model
USER MANUAL Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model 243006 NEXEL Merchandiser Refrigerator 2 Door, 53.1''W x 31.9''D x 84.4"H (with casters) For questions,
More informationInstallation Instructions If you have questions, call 800-GE-CARES or visit our website at:
Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 30" Convection Built-In Ovens Models: ZET1038 ZET1058 Monogram. We bring good things to life.
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1238566 Issued to: Rosemount Analytical Inc. Solon Research & Development Ctr 6565-P Davis Industrial Pkwy Solon, OH 44139 USA Attention: Dana Crowley The products
More informationVACUUM OVEN MODEL: 1425, 1445 & idealvac.com (505)
idealvac.com (505)872-0037 idealvac.com VACUUM OVEN MODEL: 1425, 1445 & 1465 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET:
More informationOperation & Care Instructions Save For Future Reference ABOUT THE MACHINE
Operation & Care Instructions Save For Future Reference Model Euro 930 Hepa vac Dry Canister HEPA Vacuum Cleaner This product is a high performance dry canister vacuum for commercial/industrial use. All
More informationAquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , ,
Aquatron 4, 8, 11 Instructions For Use Advance Models 56250191, 56250192, 56250193, 56250205, 56250207 10/95 Form Number 56041318 TABLE OF CONTENTS Page Introduction...2 Parts and Service...2 Nameplate...2
More informationInstallation Instructions
Design Guide with Installation Instructions Wine Reserve ZDWT240 and Beverage Center ZDBT240 monogram.com Safety Information BEFORE YOU BEGIN: Read these instructions completely and carefully. IMPORTANT
More informationInstallation Instructions
Design Guide with Installation Instructions Double-Drawer Built-In Refrigerator ZIDI240 ZIDS240 monogram.com Safety Information BEFORE YOU BEGIN: Read these instructions completely and carefully. IMPORTANT
More informationInstallation & Operation Manual
This SHEL LAB Product is Manufactured by Sheldon Manufacturing Inc. PO Box 627 Cornelius, OR 97113 Toll Free: (800)322-4897 Phone: (503)640-3000 Fax: (503)640-1366 email: tech@shellab.com web site: www.shellab.com
More informationOperation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,
VWR Vacuum Ovens Operation Manual (Version 2.0.0) VWR Vacuum Oven 10752-398, 10752-400, 10752-402 10752-404, 10752-354, 10752-356 10752-402 VWR Vacuum Oven, 30Lit. Man. V205 (10 Nov. 2015) Contents Page
More informationSHC10R-2 SHC28-2 SHC28R-2 INSTALLATION AND OPERATION INSTRUCTIONS SHC10R SHC28 SHC28R HUMIDITY CHAMBER. Revised March 19,
HUMIDITY CHAMBER SHC10 SHC10R SHC28 SHC28R SHC10-2 SHC10R-2 SHC28-2 SHC28R-2 INSTALLATION AND OPERATION INSTRUCTIONS Revised March 19, 2018 4861578 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon
More informationInstallation Instructions If you have questions, call or visit our website at:
Installation Instructions If you have questions, call 800.626.2000 or visit our website at: www.monogram.com Wine Reserve ZDWT240 and Beverage Center ZDBT240 Design Guide With Installation Instructions
More informationInstruction Manual Standard Dry Block Heaters Advanced Dry Block Heaters U L
Instruction Manual Standard Dry Block Heaters Advanced Dry Block Heaters 1 U L Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance & Servicing..............
More informationOperation Manual. (Version 1.5.1)
VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,
More informationINSTALLATION AND OPERATION MANUAL
REACH-IN DRY CO 2 INCUBATOR SCO31 SCO31-2 SCO40 SCO41-2 PREVIOUSLY DESIGNATED AS 2428 2428-2 2440 2440-2 Revised 12/2013 4861504 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627
More informationOperating Instruction Manual
COMMERCIAL INFRARED STRIP HEATER Operating Instruction Manual ESH Series Model Voltage Power Amperage Dimensions Width Depth Height *ESH-1 500W 4.2A 14" 25.5" 17.5", 20", 22.5" ESH-24 500W 4.2A 24" ESH-36
More informationVWR symphony CO 2 INCUBATORS
VWR symphony CO 2 INCUBATORS Choice Stability Protection VWR symphony INCUBATORS THE CHOICE IS YOURS The VWR symphony series provides unsurpassed performance, reliability and selection. An enhanced and
More informationUser s Manual for FT SERIES THE
User s Manual Document 1343D User s Manual for THE FT SERIES Wall-Mounted, Modulating Gas, Condensing, Heating Only, Boiler Model FTHW 80,000 BTU/hr 100,000 BTU/hr 120,000 BTU/hr 140,000 BTU/hr 199,000
More informationInstallation, Operation and Maintenance Manual
Document 453284 Model BCF Centrifugal Cabinet Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,
More informationREACH-IN INCUBATOR MODEL: RI28/RI40 2/ INSTALLATION AND OPERATIONAL MANUAL
REACH-IN INCUBATOR MODEL: RI28/RI40 2/13 4861573-1 INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationIMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.
INSTALLATION AND MAINTENANCE MANUAL StarPower Link LED Luminaire (Damp Location) Document No: 0077 Rev B Apr. 2015 IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation
More informationAGA TOTAL CONTROL. Model No. - TC3
AGA TOTAL CONTROL Model No. - TC3 Installation Guide REMEMBER: when replacing a part on this appliance, use only replacement parts that you can be assured conform to the safety and performance specification
More informationInstallation, Operation and Maintenance Manual
Document 453284 Centrifugal Cabinet Fans Model BCF Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,
More informationENVIRONMENTAL HUMIDITY CHAMBER MODEL: HC6-2 INSTALLATION AND OPERATIONAL MANUAL REV. 11/
ENVIRONMENTAL HUMIDITY CHAMBER MODEL: HC6-2 INSTALLATION AND OPERATIONAL MANUAL REV. 11/12 4861669 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationCertificate of Compliance
FF0002 Certificate of Compliance Issued to: Exheat Ltd. Threxton Road Industrial Estate Watton Thetford Norfolk, IP25 6NG UNITED KINGDOM Attention: James Pettman The products listed below are eligible
More informationOperating Instruction Manual
COMMERCIAL HEATED PIZZA/PRETZEL MERCHANDISER Operating Instruction Manual EDM-1 EDM-2 Model Voltage Power Amperage Dimensions Width Depth Height EDM-1 120V ~ 60Hz 1800W 15A 23.75" 25.5" 27.75" EDM-2 120V
More information3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure
3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure Diecast aluminium enclosure with explosion proof (Ex-e) and flame proof (Ex-d) protection suitable for use in hazardous areas,
More informationOperating Instructions
Round Tissue Bath VWR Catalog Number 80086-982 VWR Catalog Number 80086-984 Operating Instructions N2400238 Rev. 0 CONTENTS Page 1. Safety... 2 2. Product Information... 3 3. Assembly... 3 3.1 Unpacking...
More informationBench Series Ovens Models 21 / 31 / 51 Operating Manual
Heat cycle HEATER SWITCH RECIRC. FAN Quincy Lab, Inc. Bench Series Ovens Models 21 / 31 / 51 Operating Manual Standard Contents (1) Bench Series Oven (2) Adjustable chrome wire shelf (4) Shelf brackets
More informationRefrigerated Incubator Model and Operating Instructions
Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.
More informationInstallation Instructions If you have questions, call 800.GE.CARES or visit our website at:
Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com Professional Gas Cooktops 48" Natural Gas Models ZGU48N4G ZGU48N6R ZGU48N6D 48" LP Gas Models
More informationTechnical Manual for the Strobe - SM87 HXB
Technical Manual for the Strobe - SM87 HXB Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-OB16) 3 7 1 English 2 6 4 5 Module Installation This module mounts on a 1794 terminal base unit. 1. Rotate keyswitch (1) on terminal base unit (2) clockwise to
More informationInstruction Manual. Undercounter Refrigerator Models HR24B. hoshizakiamerica.com
Instruction Manual Undercounter Refrigerator Models HR24B hoshizakiamerica.com Issued: 5-11-2018 WARNING Only qualified service technicians should install and service the appliance. To obtain the name
More informationMascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH
User s Manual Document 1286A User s Information for Mascot LX Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH Combination Boiler Model MLXC 125, 150 and 175 MBH FOR YOUR
More informationAB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document
Installation Instructions ControlNet Coax Tap (Cat. Nos. 1786-TPR, -TPS, -TPYR, -TPYS) What s in This Document Use this document as a guide when installing a ControlNet coax tap. To: See Page: verify package
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationOperating Instruction Manual
COMMERCIAL ELECTRIC WARMER or WARMER/COOKER Operating Instruction Manual FW-S500 Warmer FW-S600 Warmer/Cooker Model Description Size Voltage Hz Wattage FW-S500 Electric Warmer 22-⅜"L x 14-9/16"W x 9-½"H
More informationINSTALLATION AND OPERATION MANUAL
LOW TEMPERATURE DIURNAL ILLUMINATION INCUBATOR SRI21D SRI21D-2 Previously designated as: LI15 LI15-2 INSTALLATION AND OPERATION MANUAL Revised 4/2015 4861575 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius,
More informationTEC210x-2 Series Networked Thermostats
Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationFisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual
Fisher Scientific Isotemp Muffle Furnace 550 Series Instruction Manual Model 14 Catalog No: 10-550-14 & 14A Model 58 Catalog No: 10-550-58 Model 126 Catalog No: 10-550-126 Service Division (Repairs):
More informationPOPCORN POPPER. Operating Instruction Manual COMMERCIAL. Dimensions Width Depth Height. Model Voltage Power Amperage
COMMERCIAL POPCORN POPPER Operating Instruction Manual POP-8B POP-8R Model Voltage Power Amperage Dimensions Width Depth Height POP-8B 1130 W 9.5A 15.75" 14.75" 23" 120V ~ 60Hz POP-8R 1350 W 12A 22" 16.5"
More informationVacuum drying VD VDL series
Vacuum drying VD VDL series Extremely superior: BINDER Vacuum drying ovens u Extremely fast u Direct heat transfer to the sample material through thermal conducting plates u Fast, condensation-free drying
More informationWarmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R
CM CAUTION: Read all instructions carefully before installation. Save this Installation Manual for future reference. Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL ENCLOSURE TYPE 3R AUTOMATED
More informationSEL-3422 Motor Relay HMI Quick-Start Guide
SEL-3422 Motor Relay HMI Quick-Start Guide Overview The SEL-3422 Motor Relay HMI indicates the SEL-849 operation status through the ten LEDs on its front panel. Eight of these LEDs are programmable. The
More informationWireless Outdoor Air Reset Adaptor PN:
Wireless Outdoor Air Reset Adaptor PN: 105767-01 Instruction Sheet APPLICATION The Wireless Outdoor Air Reset Adaptor, when connected to the Concert Boiler Control enables efficiency control functionality
More informationTechnical Specification VFD
Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and
More informationInstallation Instructions If you have questions, call or visit our website at:
Installation Instructions If you have questions, call 800.626.2000 or visit our website at: www.monogram.com Outdoor/Indoor Refrigerator ZDOD240 Design Guide With Installation Instructions Safety Information
More informationFisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0
Fisher Scientific Model 281A Vacuum Oven Installation and Operating Manual 30979 Rev. 0 Preface Models covered in this manual: Catalog numbers Models numbers Voltage 13-262-50 6288 120V 13-262-51 6289
More informationLED Bottle Cooler. Maintenance for. I1457 Iss. 4 Jan 2014 Copyright Glen Dimplex Professional Appliances
Maintenance for LED Bottle Cooler Lec Commercial Glen Dimplex Professional Appliances A division of Glen Dimplex Home Appliances Stoney Lane, Prescot, Merseyside, L35 2XW Great Britain T: 0871 222 5119
More informationInstallation Instructions If you have questions, call or visit our website at:
Installation Instructions If you have questions, call 800.626.2000 or visit our website at: www.monogram.com Wine Chiller ZDWC240NBS and Beverage Center ZDBC240NBS Design Guide With Installation Instructions
More informationTEC2100 Series Networked Thermostats
Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationSystem 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules
FANs 930, 125 Product/Technical Bulletin S350 Issue Date April 8, 2014 System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s The S350A, S351A, and S352A Stage s are intended to be used
More informationOwner s Manual Phoenix CAM Pro
4201 Lien Rd. Madison, WI 53704 Owner s Manual Pro Installation, Operation & Service Instructions Read and Save These Instructions Low amp draw, balanced airflow characteristics and maximum velocity of
More informationConnection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven
Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven 9990033 1 TABLE OF CONTENTS SECTION 1.0 SECTION 2.0 SECTION 3.0 SECTION 4.0 SECTION 5.0 SECTION 6.0 PRECAUTIONS SAFETY CONNECTION KIT
More informationCAUTION CAUTION WARNING. Vulcan RT Heater With Remote Temperature Controller
Congratulations for choosing VULCAN RT electric heating system. It is loaded with 37,000 BTU s (11KW) of heat power, 475 CFM of air flow and precise temperature controls. It features individually controlled
More informationINSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm
More informationInstruction Manual. Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL. hoshizakiamerica.
Instruction Manual Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL hoshizakiamerica.com Issued: 5-1-2017 WARNING Only qualifi ed service technicians should install
More information