Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Size: px
Start display at page:

Download "Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST"

Transcription

1 Base eries Fan Coil izes 024, 036, 048 and 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The direct expansion fan coils are designed to cover a wide range of air handling requirements. They are compact and ready to fit where needed in the basement, crawlspace, attic, utility room, or closet. The unique cabinet design of these fan coils meet new stringent regulations for cabinet air leakage a requirement of 2% cabinet leakage rate when tested at 1.0 inches of static pressure. All units come with solid state fan controls, 1 -inch thick insulation with R value of 4.2, super -quiet multispeed motors, and fully wettable coils. Units can accommodate field -installed heaters from 3 to 30 kw.

2 TANDARD FEATURE Grooved copper tubing Lanced sine-wave aluminum fin Fully -wettable coil High -impact thermoplastic condensate pan Primary and secondary drain connections with brass inserts Multipoise design for maximum versatility Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2% cabinet leakage rate when tested at 1.0 inches of static pressure. Field -installed heater packages from 3-30 kw (fused, circuit breaker, or non -fused) Control board with built -in, replaceable 5 -amp blade -type auto fuse Cooling controls Time -delay relay (TDR) Pre -painted galvanized steel cabinet High -density, super-thick R -4.2 insulation Newly -improved filter rack area filter door insulation added for an improved air seal weat connections Inspection plate for cleaning A -coil design HUD approved for manufactured housing 40 -VA, 208/230v transformer 024, 036, 048 and 060 sizes AccuRaterr metering device 3 -speed motor on all sizes Factory -supplied, cleanable, permanent framed filter Factory -supplied power plug Multiple electric entry ADDITIONAL FEATURE 2

3 NOMENCLATURE CHART CARRIER FAN COIL , 8, 9 10, 11, F B 4 B N L A A A A Product eries Type Position Major eries Electrical Cabinet/Insulation Nominal Capacity (Btu) Heating ize (kw) Variations F=FanCoil B=tandard, R = Multipoise B N = 208/230v 1ph---60hz L=LatinAmerican Export 024 = 24, = 36, = 48, = 60, No Heat IO 9001:2000 REGITERED 3

4 DIMENION A06165 UNIT IZE COIL TYPE A B C D E J IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM 024 lope / / / / / lope / / / / / A / / / / / A / / / / /

5 DIMENION (CONT.) A05356 UNIT IZE COIL TYPE F G IN. MM IN. MM 024 lope / / lope / / A / / A / /

6 PECIFICATION MODEL hipping Weight (Lb) Refrigerant Metering Device Bypass AccuRaterR Piston ize COIL Rows and Fins Per In. 3 and 14.5 Face Area (q Ft) Configuration lope lope A A FAN AirDischargeCFM(Nominal)MotorHp(PC) 850 1/ / / /4 FILTER IZE /2 x /2 x / /2 x /8 FILTER CABINET CONFIGURATION OPTION piece piece piece piece AIRFLOW PERFORMANCE (CFM) PERFORMANCE DATA IZE BLOWER MOTOR PEED TOTALEXTERNALTATICPREURE(IN.WC) V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V High Medium Low High Medium Low High Medium Low High Medium Low NOTE: 1. Airflow based upon dry coil at 230v with factory approved filter and electric heater (2 element heater, sizes 024 and 036; 3 element heater, sizes 048 and 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.4 in. wc. Horizontal applications of sizes must have supply static greater than 0.20 in.wc. Airflow outside max ARI airflow of 450 cfm/ton on sizes. Airflow above 400 cfm/ton on sizes. Airflows in this region could result in condensate blowing off coil or splashing out of drain pan. MINIMUM CFM AND MOTOR PEED ELECTION IZE HEATER KW * *Indicates medium speed (blue). All other motor speeds at low tap. FACTORY -INTALLED ACCEORY FILTER TATIC PREURE DROP (IN. WC) UNIT IZE CFM

7 ELECTRIC HEATER TATIC PREURE DROP (IN. WC) HEATER ELEMENT KW EXTERNAL TATIC PREURE CORRECTION HEATER ELEMENT KW EXTERNAL TATIC PREURE CORRECTION , , , , , , 24, The airflow performance data was developed using fan coils with 10---kW electric heaters (2 elements) in the 024 and 036 size units and 15---kW heaters (3 elements) in the 048 and 060 size units. For fan coils with heaters of a different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PREURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY -TO -WET COIL) IZE CFM NOTE: ubtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. GRO COOLING CAPACITIE (MBH) UNIT EVAPORATOR AIR CFM AND BF COIL REFRIGERANT TEMPERATURE ( F)* Evaporator Air Entering Wet---Bulb Temp ( F) CFM - Cubic Ft. per Minute EWB - Entering Wet Bulb (_F) LWB - Leaving Wet Bulb (_F) TC - Gross Cooling Capacity 1000 Btuh HC - Gross ensible Capacity 1000 Btuh BF - Bypass Factor MBH Btuh 7

8 NOTE: 1. Contact manufacturer for cooling capacities at conditions other thanshownintable. 2. Formulas: Leaving db = entering db ---sensible heat cap x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (h lwb ) h lwb =h ewb ---total capacity (Btuh) 4.5 x CFM where h ewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. HC is based on 80_F db temperature of air entering coil. Below 80_F db, subtract (Correction Factor x CFM) from HC. Above 80_F db, add (Correction Factor x CFM) to HC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. BYPA FACTOR HC CORRECTION FACTOR ENTERING AIR DRY-- BULB TEMPERATURE (_F) Under Over 85 Correction Factor Use formula shown below Interpolation is permissible. Correction Factor = 1.09 x (1 --- BF) x (db ) ACCEORY ELECTRIC HEATER HEATER PART NO. VOLT/ TAGE (KW INTERNAL CIRCUIT FAN COIL IZE HEATING CAP.** 240V PH OPERATING) PROTECTION UED 230V KFCEH0401N /1 3 None ,400 KFCEH0501N /1 5 None ,700 KFCEH0801N /1 8 None ,100 KFCEH0901N /1 10 None ,400 KFCEH /3 5, 15 None ,100 KFCEH /3 6, 12, 18 None ,500 KFCEH2401C /1 5 Circuit Breaker ,700 KFCEH2501C /1 8 Circuit Breaker ,100 KFCEH2601C /1 10 Circuit Breaker ,400 KFCEH2901N /1 3, 9 None ,200 KFCEH3001F /1 5, 15 Fuse ,100 KFCEH3101C /1 5, 15 Circuit Breaker ,100 KFCEH3201F /1 5, 20 Fuse ,800 KFCEH3301C /1 5, 20 Circuit Breaker ,800 KFCEH3401F /3* 8, 16, 24 Fuse 048, 060, ,300 KFCEH3501F /3* 10, 20, 30 Fuse 048, 060, ,100 * Field convertible to 1 phase. { Fieldconvertibleto3phase. } ingle point wiring kit required for these heaters in Canada. ** Blower motor heat not included. ETIMATED OUND POWER LEVEL (dba) CONDITION OCTAVE BAND CENTER FREQUENCY* IZE Ext tatic CFM Pressure * Estimated sound power levels have been derived using the method described in the 1987 AHRAE HVAC ystems & Applications Handbook, Chapter 52, p FAN COIL ELECTRICAL DATA (UNIT WITHOUT ELECTRICAL HEAT) BRANCH CIRCUIT IZE VOLT (1 PHAE) FLA MIN CKT AMP Min Wire ize Fuse Amps Awg* / / / / *Usecopperwireonly.Use75_C only in this application. When using non---metallic (NM) sheathed cable, wire size required should be based on that of 60_C conductors, instead of wire sizes shown in table above per NEC Article FLA --- Full Load Amps NOTE: If branch circuit wire length exceeds 100 ft, consult NEC to determine maximum wire length. Use 2% voltage drop. 8

9 ACCEORY ELECTRIC HEATER ELECTRICAL DATA HEATER PART NO. KW P H A E INTERNAL CIRCUIT PROTEC- TION ingle Circuit HEATER AMP 208/230V Dual Circuit ingle Circuit Min Ampacity 208/230V** Dual Circuit 240v 208v L1,L2 L3,L4 L1,L2 L3,L4 Min Wire ize (AWG) 208/230V ingle Circuit Dual Circuit L1,L L3,L 2 4 BRANCH CIRCUIT ingle Circuit Min Gnd Wire ize 208/230V Dual Circuit L1,L L3,L 2 4 Max Fuse/Ckt Bkr Amps 208/230V ingle Circuit Dual Circuit ingle Circuit Max Wire Length 208/230V (Ft) Dual Circuit L1,L2 L3,L4 L1,L2 L3,L4 KFCEH0401N None 10.9/ / /12 12/12 20/20 67/68 KFCEH0501N None 18.1/ / /10 10/10 30/30 66/66 KFCEH0501N None 18.1/ /33.5 8/8 10/10 35/35 85/88 KFCEH2401C Ckt Bkr 18.1/ / /10 10/10 30/30 66/66 KFCEH2401C Ckt Bkr 18.1/ /33.5 8/8 10/10 35/35 85/88 KFCEH0801N None 28.9/ /48.5 8/8 10/10 45/50 59/60 KFCEH2501C Ckt Bkr 28.9/ /48.5 8/8 10/10 45/50 59/60 KFCEH2901N09* None 32.8/ /53.5 8/6 10/10 50/60 54/87 KFCEH2901N09 * None 18.8/ /34.5 8/8 10/10 35/35 83/85 KFCEH0901N None 36.2/ /58.5 6/6 10/10 60/60 78/80 KFCEH2601C Ckt Bkr 36.2/ /58.5 6/6 10/10 60/60 78/80 KFCEH3001F15* Fuse 54.2/ / / / / /25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFCEH3101C15* Ckt Bkr 36.2/ / / /25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76 KFCEH None 31.3/ /51.8 8/6 10/10 50/60 56/90 KFCEH None 37.6/ /60.4 6/6 10/8 60/70 76/77 KFCEH3201F20* Fuse 72.3/ / / / / /50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFCEH3301C20* Ckt Bkr 36.2/ / / /50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59 KFCEH3401F24 * KFCEH3501F30 * Fuse 50.1/ /77.8 4/4 8/8 80/80 94/ Fuse 86.7/ / /1 6/6 125/ / Fuse 62.6/ /95.0 3/3 8/8 90/100 97/ Fuse 109.0/ / /00 6/6 150/ /150 FIELD MULTIPOINT WIRING OF 24 -AND 30 -KW INGLE PHAE HEATER PART NO. HEATER AMP MIN AMPACITY MIN WIRE IZE (AWG) KW MIN GND MAX FUE/CKT BKR AMP MAX WIRE LENGTH PHAE 208/230V 208/230V** 208/230V WIRE IZE 208/230V 208/230V (FT) 240V 208V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 208/230V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 KFCEH3401F24 * / / / / / /40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFCEH3501F30 * / / / / / /50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 * Heaters are Intelligent Heat capable when used with the FE, FK and FV fan coils and corporate 2---speed programmable thermostat (TTATCCP201---B), Thermidistatt Control (TTATCCPRH01---B), or Comfort Zone II. { Field convertible to 1 phase, single or multiple supply circuit. } Field convertible to 3 phase. ** Includes blower motor amps of largest fan coil used with heater. {{ Copper wire must be used. If other than uncoated (non---plated), 75_C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANI/NFPA 70). }} Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. NOTE: 1. For fan coil sizes For fan coil sizes and all FK4D, FV4B sizes. 3. ingle circuit application of F15 and F20 heaters requires single---point wiring kit accessory. 9

10 ELECTRIC HEATER INTERNAL PROTECTION* HEATER KW PHAE FUE QTY/IZE CKT BKR QTY/IZE{ / / / /30 2/60 2/ /60 2/ /3 6/ /3 6/60 9 1/ * 5 ---, 8 ---, kw factory ---installed heat has no internal protection kw factory ---installed heat is internally protected with fuses. { Circuit breakers are 2 pole. 10

11 ACCEORIE ITEM ACCEORY PART NO.* FAN COIL IZE UED WITH 1. Disconnect Kit KFADK0201DC Cooling controls and heaters 3--- through kw KFACB0101CFB Downflow Base Kit KFACB0201CFB 036 KFACB0301CFB 048, Downflow Conversion Kit KFADC0201LP lope Coil Units 024, 036 KFADC0401ACL A--- Coil Units 048, ingle--- Point Wiring Kit KFAP0101PK Only with and kw Fused Heaters KFAFK0212ML Filter Kit (12 Pack) KFAFK0312MED 036 KFAFK0412LRG 048, PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 7. Air Cleaner volt Conversion Kit KEAVC All 8. Downflow/Horizontal Conversion Gasket Kit KFAHD0101LP All 9. Horizontal Water Management Kit (25 pack) KFAHC0125AAA All * Factory authorized and listed, field---installed. Accessory Kits Description uggested and Required Use. 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. UGGETED UE: Units for 3 - through 10 -kw electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1 -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap -free seal with the floor. REQUIRED UE: This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. eparate kits are available for slope coils and A -coils. REQUIRED UE: This kit must be used whenever fan coils are used in downflow applications. 4. ingle Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy -gauge, high -voltage wires into the fan coil rather than 4 light-gauge, high -voltage wires. UGGETED UE: Fan coils with 15 - and 20 -kw fused heaters only. 5. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. UGGETED UE: To replace filters in fan coils. REQUIRED UE: All units unless a filter grille is used. 6. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. UGGETED UE: All fan coils. 7. Air Cleaner 240 -volt Conversion Kit The AIRA electronic air cleaner comes ready for 115 -v operation. REQUIRED UE: This kit is required when running 240 -volt circuit to air cleaner. 8. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED UE: Fan coils in either downflow or horizontal applications. 9. Horizontal Applications - Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. UGGETED UE: All fan coils. 11

12 Copyright 2006 Carrier Corp W. Morris t. Indianapolis, IN Printed in U..A. Edition Date: 05/06 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: --- L1PD Replaces: New 12

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 001 thru 004 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The series fan coils are reliable, dependable, and a great value. These fan coils offer air handling for practical,

More information

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST , Base eries Fan Coil izes 018 Thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The and direct-expansion fan coils are designed to cover a wide range of air handling requirements. They are compact

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST PF4MNP FAN COIL IZE 018 THRU 060 Product Data The PF4MNP fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the

More information

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET A10082 The fan coil has the proven technology of Carrier fan coil units with Puron refrigerant as well as vertical

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006 FE4A, FE5A Infinityt eries Communicating Variable---peed Fan Coil Puronr Refrigerant izes 002 thru 006 Product Data PREMIUM ENVIRONMENTALLY -OUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006 Product Data FK4D Direct Expansion Variable Speed Fan Coil Sizes 001 thru 006 A02332 FK4D Premium Air Handling Technology The FK4D is the latest in air handling technology. It is the perfect unit when

More information

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST Base Series Fan Coil Sizes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST A10082 The fan coil combines the proven technology of Carrier fan coil units with the flexibility to handle both

More information

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006 FE4A, FE5A Infinityt eries Communicating Variable---peed Fan Coil Puronr Refrigerant izes 002 thru 006 Product Data PREMIUM ENVIRONMENTALLY -OUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

Product Data. FE4A, FE5A Infinityr Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Product Data. FE4A, FE5A Infinityr Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006 FE4A, FE5A Infinityr eries Communicating Variable---peed Fan Coil Puronr Refrigerant izes 002 thru 006 Product Data PREMIUM ENVIRONMENTALLY -OUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

FAN UNIT FH4A Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004 FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3 DIRECT EXPANSION FAN COIL MODEL FK4C Sizes 001 thru 006 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler

More information

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg) FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating

More information

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006 FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The latest in technology makes the FE4A and FE5A

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006 Product Data FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler available.

More information

FCM4X. Product Specifications

FCM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FCM4X Product Specifications FAN COILS WITH OBSERVER COMMUNICATING CONTROL Smart Diagnostics Easier troubleshooting, providing faster service and repair Environmentally

More information

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal Product Data 40FKA Comfort Heat Pump System Fan Coil Sizes 002 thru 006 THERMIDISTAT CONTROL OUTDOOR TEMPERATURE SENSOR 40FKA FAN COIL Comfort Heat Pump System Fan Coil and Thermidistat Control Revolutionizing

More information

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006 Product Data FK4C Direct Expansion Fan Coil Sizes 00 thru 00 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat

More information

FXM4X. Product Specifications FAN COILS FXM4X

FXM4X. Product Specifications FAN COILS FXM4X ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper

More information

WAHL A Product Specifications

WAHL A Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

FEM4X. Product Specifications FAN COILS /14/15

FEM4X. Product Specifications FAN COILS /14/15 ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator

More information

REM4P, REM4X. Product Specifications

REM4P, REM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with

More information

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device

More information

Dimensions H x W x D in. (mm)

Dimensions H x W x D in. (mm) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES 180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.

More information

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT

More information

Table of Contents. Page 2

Table of Contents. Page 2 FB4P Fan Coil Units 60Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing Co. Ltd. Country

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS MULTIPOIE OIL FURNACE INPUT RATE: 70,000 thru 154,000 BTUH ERIE 130 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06625 The model combines high efficiency and quiet operation with oil heating technology.

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY Multipoise Oil Furnace Input Capacities: 70,000 thru 154,000 Btuh eries 130 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06625 The model combines high efficiency and quiet operation with oil heating

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed MULTIPOIE OIL FURNACE INPUT CAPACITIE: 70,000 THRU 112,000 BTUH Product Data THE LATET IN OIL FURNACE TECHNOLOGY A10311 The models OBM and OVM combine high efficiency and quiet operation with oil heating

More information

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY Multipoise Oil Furnace Input Capacities; 70,000 thru 154,000 Btuh eries D Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06623 The model combines high efficiency and quiet operation with oil heating

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL Product Data CF5A COILS KMABA BLOWERS For Manufactured Homes THE CF5A INDOOR COIL To complete your cooling or heating system, the model CF5A Coil is installed inside your Evcon/Coleman, Nordyne/Miller/Intertherm,

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060 40QAC / 38HDR 40QAQ / 38QRR Ceiling---uspended Duct Free plit ystem izes 018 to 060 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38HDR(QRR)/40QAC(QAQ)

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free plit ystem izes 009 to 024 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38/40MVC(Q) series duct-free

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-509 REV. 8 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS LOW --- BOY OIL FURNACE INPUT RATE: 70,000 thru 154,000 BTUH ERIE 110 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06626 The model combines variable -speed high efficiency and quiet operation with

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet 2---tage Air Conditioner with r Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with r refrigerant provide a collection of features unmatched

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial

More information

FUSE COVER CLIP LATCH (OMITTED ON 18-K3N)

FUSE COVER CLIP LATCH (OMITTED ON 18-K3N) Installation Instructions Electric Heater Packages KFCEH TE: Read the entire instruction manual before starting the installation. This symbol --4 indicates a change since the last issue. SINGLE-( GROUND

More information

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling Product Data 28CB, Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Direct-expansion evaporator coils easily accommodate upflow or horizontal light-commercial applications Features/Benefits

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling Product Data 28CB, 28LA Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Copyright 2001 Carrier Corporation 28LA Direct-expansion evaporator coils that easily accommodate upflow

More information

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY Multipoise Oil Furnace Input Capacities: 70,000 thru 154,000 Btuh eries 110 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06625 The model combines variable -speed high efficiency and quiet operation

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information