Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase
|
|
- Rosalyn White
- 5 years ago
- Views:
Transcription
1 Starters and Contactors Definite Purpose Contactors Standard, Open Type Ampere Rating Coil Voltage No of Pole Voltage CR353AB2AA1GE 25 50/60 Hz CR353AC3AH1GE /60 Hz CR353FF3BA1GE 60 50/60 Hz Indoor Enclosure Kit - NEMA Type 1 Enclosure Kits - NEMA Type 1 Rating CR353XE1BBGE 25A-40A, 4-pole 50A-60A, Contactors Device Enclosure Kits NEMA Type 1 3-pole Full Voltage Contactors Ampere Rating Coil Voltage No of Pole 453AB3AAAGE 25 50/60 Hz 3 453AC2AAAGE 30 50/60 Hz 2 453AC3AAAGE 30 50/60 Hz 3 453AC3BAAGE 30 50/60 Hz 3 453AD3ABBGE 40 50/60 Hz 3 453AD3BAAGE 40 50/60 Hz 3 Magnetic Starters Full Voltage Starters - Magnetic, CR306 Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase Three-Phase Magnetic Starters, NEMA Type 1 Ampere Rating Coil Voltage NEMA Size Phase Voltage CR306B102GE Max 0 3 Separate Control V CR306C102GE Max 1 3 Separate Control V CR306D102GE Max 2 3 Separate Control V 1
2 Starters and Contactors Magnetic Starters Full Voltage Starters - Magnetic, CR306 Three-Phase Magnetic Starters, Open Type Ampere Coil Voltage NEMA Size Phase Voltage Rating CR306A002GE Max 00 3 Separate Control V CR306B002GE Max 0 3 Separate Control V CR306C002GE Max 1 3 Separate Control V CR306D002GE Max 2 3 Separate Control V Magnetic Starter Accessories Enclosure, Nonreversing Height Width Depth NEMA Size Use with CR306X190KGE 14.50" 6.88" 4.75" 00, 0, 1 CR306 A, B, C Nonreversing Combination Starter Enclosure Kit For NEMA Rated Full Voltage Starters (300-Line) Pilot Device Modification Kits - Push Button NEMA Size CR305X120NGE 00, 0, 1 Momentary Contact Start-Stop Push Button Kits For 300-Line Starter CR305X220NGE 2 Momentary Contact Start-Stop Push Button Kits For 300-Line Starter Pilot Device Modification Kits - Selector Switch NEMA Size CR305X130NGE 00, 0, 1 Hand-Off-Auto Selector Switch Kits For 300-Line Starter 2
3 Starters and Contactors Magnetic Starter Accessories Auxiliary Contact Kits Contact NEMA Size Configuration CR305X100CGE 1NO-1NC 0,1 NEMA Auxiliary Contact Kit, Basic Block For 300-Line Starter Heaters for Motor Starter Maximum Full Load Amps CR123C131AGE A Motor Starter Heater CR123C184AGE A Motor Starter Heater CR123C196AGE A Motor Starter Heater CR123C239AGE A Motor Starter Heater CR123C268AGE A Motor Starter Heater CR123C326AGE A Motor Starter Heater CR123C356AGE A Motor Starter Heater CR123C379AGE A Motor Starter Heater CR123C419AGE A Motor Starter Heater CR123C466AGE A Motor Starter Heater CR123C526AGE A Motor Starter Heater CR123C592AGE A Motor Starter Heater CR123C695AGE A Motor Starter Heater CR123C778AGE A Motor Starter Heater CR123C867AGE A Motor Starter Heater CR123C955AGE A Motor Starter Heater CR123C104BGE A Motor Starter Heater CR123C113BGE A Motor Starter Heater CR123C137BGE A Motor Starter Heater CR123C151BGE A Motor Starter Heater CR123C163BGE A Motor Starter Heater CR123C180BGE A Motor Starter Heater CR123C198BGE A Motor Starter Heater CR123C214BGE A Motor Starter Heater CR123C228BGE A Motor Starter Heater CR123C250BGE A Motor Starter Heater CR123C273BGE A Motor Starter Heater CR123C303BGE A Motor Starter Heater CR123C366BGE A Motor Starter Heater CR123F487BGE A Motor Starter Heater CR123C460BGE 45 45A Motor Starter Heater CR123F567BGE A Motor Starter Heater CR123F719BGE A Motor Starter Heater CR123F772BGE A Motor Starter Heater CR123F848BGE A Motor Starter Heater CR123F914BGE A Motor Starter Heater CR123F104CGE A Motor Starter Heater 3
4 Starters and Contactors Magnetic Coils Voltage NEMA Size 15D21G002GE , 0, 1 Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D21G003GE , 0, 1 Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D21G004GE , 0, 1 Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D21G023GE , 0, 1 Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D22G002GE Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D22G003GE Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D22G005GE Magnet Coil for NEMA Rated 300- and 200-Line Magnetic 15D22G023GE Magnet Coil for NEMA Rated 300- and 200-Line Magnetic Manual Starters, Non-Reversing, Single Phase Enclosed NEMA Type 1 Features: Single-Phase Non-combination 1 HP Maximum at 115 or 230 Volts 3/4 HP Maximum at 277 Volts for 2 pole forms 25 to 60 Hz Surface mounting Voltage Number of Pole CR101Y1GE Toggle-Operated, Nonreversing, Motor Switch, Manual CR101H1GE Toggle-Operated, Nonreversing, Motor Switch, Manual Overload Heater Units CR123H317AGE CR123H486AGE CR123H575AGE CR123H625AGE CR123H739AGE CR123H873AGE CR123H112BGE CR123H122BGE CR123H144BGE CR123H186BGE 2.76A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 4.22A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 5.00A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 5.43A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 6.41A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 7.60A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 9.75A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 10.60A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 12.50A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 16.0A Overload Heater Unit for CR101H,Y NEMA Rated Full Voltage Manual Starter 4
5 Starters and Contactors Manual Starters, Non-Reversing, Three Phase Enclosed NEMA Type 1 Frequency HP Maximum NEMA Size Operator Type Phase CR1062R3AAP2GE 25 to 60 Hz 10 M-0 Push Button 3 CR1062S3AAP2GE 25 to 60 Hz 10 M-1 Push Button 3 Heater Selection for CR106 Line CR123C131AGE CR123C184AGE CR123C196AGE CR123C239AGE CR123C268AGE CR123C326AGE CR123C356AGE CR123C379AGE CR123C419AGE CR123C466AGE CR123C526AGE CR123C592AGE CR123C695AGE CR123C778AGE CR123C867AGE CR123C955AGE CR123C104BGE 1.12A Overload Heater Unit for CR106 Line 1.48A Overload Heater Unit for CR106 Line 1.66A Overload Heater Unit for CR106 Line 2.03A Overload Heater Unit for CR106 Line 2.28A Overload Heater Unit for CR106 Line 2.71A Overload Heater Unit for CR106 Line 2.87A Overload Heater Unit for CR106 Line 3.18A Overload Heater Unit for CR106 Line 3.54A Overload Heater Unit for CR106 Line 3.89A Overload Heater Unit for CR106 Line 4.51A Overload Heater Unit for CR106 Line 4.90A Overload Heater Unit for CR106 Line 5.94A Overload Heater Unit for CR106 Line 6.70A Overload Heater Unit for CR106 Line 7.36A Overload Heater Unit for CR106 Line 7.98A Overload Heater Unit for CR106 Line 8.59A Overload Heater Unit for CR106 Line Lighting Contactors Contactor Base Features: Combined with other appropriate components, basic contactors allow configuration into any available electrically or mechanically held model Includes two power poles Coil Voltage 463L20AJAGE 110V / 50/60 Hz Basic Contactor Base with 2NO 5
6 Starters and Contactors Lighting Contactors Power Poles CR460 Series basic contactors accept up to 6 single or double pole power poles. These can be used to form up to: 12 NO poles when 6 double-poles are used in the NO positions (1-6) 8 NC poles with 4 double-poles in the NC positions (1-4) + 4 NO poles with 2 double-poles in the 2 NO positions (5-6) Number of Pole 460XP32GE 2 Power Poles, Double Pole Components Spare Coils 460XCNGE 460XCUGE Spare Coils, 240 VAC@50 Hz, 277 VAC@ 60 Hz Spare Coils, 440 VAC@50 Hz, VAC@60 Hz Enclosure Kits - NEMA Type 1 Enclosure Type 460XE1BGE NEMA Type 1 Enclosure Kits NEMA 1 with no CPT or Pilot Devices 6
I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled
I P Explosion Proof Starter 1Ø & 3Ø, 115~600VAC, 1 75HP START/STOP AND RESET PUSHBUTTONS ELECTRONIC MOTOR PROTECTION Tough Starters for Tough Environments Ready to Install, Completely Wired and Assembled
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018
SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS
SECTION 26 09 23 LIGHTING CONTROL DEVICES AND CONTROL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Remote control lighting relays. 2. Lighting contactors. 3. Switches. 4. Switch plates.
More informationAPPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS
CONTINUOUS HEAVY DUTY CYCLING OF MOTORS MINING PETROCHEMICAL PULP & PAPER ROCK CRUSHING OIL PUMPING WATER/WASTEWATER TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS. NEMA VACUUM CONTACTORS NEMA VACUUM OPEN
More informationSECTION ENCLOSED CONTROLLERS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes ac,
More informationGate Operator. Modfications
Gate Operator Modfications 100va Transformer G90 100 OP1 - Single Phase G90 100 OP3 -Three Phase Upgrades the transformer in the operator enclosure from 40va to 100va. Provides additional control circuit
More informationNEMA Manual. Starters. NEMA Manual Starters Contents
- February 007 NEMA Manual Starters Contents Page Types B0, B0, Switches.................................... - MS Series, Single-Phase Starters................................ -4 Type B00, Single- and
More informationSECTION HEATING BOILER FEEDWATER EQUIPMENT
SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American
More informationKIC Air Curtains. Technical Guide
TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The
More informationCR1 Series Triton Corrosion Resistant Washdown Heaters
CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging
More informationCR Series Command Relays
CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for
More informationBULLETIN 600 SINGLE PHASE
BULLETIN 600 SINGLE PHASE Bulletin 600 Starting and overload protection of small 1-phase AC/DC motors used on the following: Unit heaters Fans Stokers Pumps Refrigeration compressors Bulletin 600 manual
More informationEG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G
E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5
More informationSECTION STEAM CONDENSATE PUMPS
SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although
More informationFluid Cooler Fan and Pump control panel
user manual Fluid Cooler Fan and Pump control panel INSTALLATION - OPERATION - MAINTENANCE Z02819_A M03-171B ISSUED 07/2014 0/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR OR SERVICING THIS
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More information1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.
Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1
More informationAir Conditioning, refrigeration and Appliance Transformers
Air Conditioning, refrigeration and Appliance Transformers 10 Section An economical approach to changing world voltages to 115V for operation of air conditioners, refrigeration equipment, appliances, business
More informationTransfer Switch Features
1-1 Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer
More informationTwo-Position Electric Duplex Room Thermostats
TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features:
More informationSECTION LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationUltra-Safe EXP Unit Heater
INDEEO s ULTRA-SAFE EXP explosion-proof unit heater is designed with both safety and versatility in mind. Unique ULTRA-SAFE EXP features include: Industry s Lowest Ignition Temperature ode Rating: T3,
More informationElectric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features
Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks
More informationFDF Foam Pump Controllers Features
FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for
More informationSECTION EXTERIOR LIGHTING
SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26
More information100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4
Contactor Panel with GFEP Data Sheet GENERAL PRODUCT INFORMATION Simplify your snowmelt installation with ProLine Radiant contactor panels with built in GFEP. These rugged panels feature built-in ground
More informationMETRO SEWER DISTRCT (MSD), CINCINNATI, OHIO DETAILED PROVISIONS FOR ELECTRICAL PUMP CONTROL PANELS FOR PUMP OR LIFT STATIONS
METRO SEWER DISTRCT (MSD), CINCINNATI, OHIO DETAILED PROVISIONS FOR ELECTRICAL PUMP CONTROL PANELS FOR PUMP OR LIFT STATIONS PART 1 - GENERAL 1.01 Scope A. The contractor shall furnish all labor, materials,
More informationLMR Electric Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationTM Series. Induced Draft, Counter Flow Optional Accessories
ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
More informationFusible Shunt. Trip Switch. Operation and Maintenance Manual SOLUTIONS GUIDE
Fusible Shunt Trip Switch Operation and Maintenance Manual SOLUTIONS GUIDE Table of Contents Device Overview....2 Installation Instructions....3 Catalog Number Selection Table...4 Motor Fuse Selection
More informationWiring Diagrams Units Produced After April 20, 2009
UNIT 38AH 0-034 Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, 460-3-60 575-3-60 380-3-60-3-50, 380/415-3-50
More informationParagon. Induced Draft, Counter Flow Optional Accessories
ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationa thriving company in a dynamic industry
a thriving company in a dynamic industry At Sprecher + Schuh, helping our customers succeed is what we do best with industrial control and informative solutions designed to give our customers a competitive
More informationLMR Electric Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationEATON DFDAP-M / FDAP-M Remote Alarm Panels
O & M Manual IM05805008K O & M Manual IM05805008K TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER 1 2. ELECTRICAL CONNECTIONS 1 2.1 ELECTRICAL CHECKOUT INSTRUCTIONS 2 2.2 ELECTRIC ALARM
More informationPOWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.
POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. CUSTOM CONFIGURED PRODUCTS READY FOR SHIPMENT IN ONE TO TEN BUSINESS DAYS. Appleton s Quick Response Program places select power and control products
More informationConstruction Electrical
INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify
More informationB. Section Transfer Switches: Automatic transfer switch.
SECTION 263213 - ENGINE GENERATORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Packaged engine generator set. B. Exhaust silencer and fittings. C. Remote control panel. D. Battery and charger. E. Weatherproof
More informationTransfer Switch Features
1-1 Product Description The Automatic Transfer Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer and
More informationDescription Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)
INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2
More informationTRX MAINS CONNECTION DIAGRAM
TRX MAINS CONNECTION DIAGRAM Switch 230VAC 10A Neutral Out Phase Out TRX MAINS Phase In Neutral In LOAD 8A MAX. Specifications: Operating Voltage: 220-240VAC 50Hz Current Draw: 5mA Max. Switching Current:
More informationACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F
II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy
More informationMotogard. Over Temperature Protection System. Installation Instructions
Motogard Over Temperature Protection System Installation Instructions Motogard General Information Motogard Over-Temperature Protection Systems provide immediate overheating protection for: motors, equipment
More informationMASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model
More informationElevator Control ES Switch
Technical Data TD00801003E Contents Description Page Danger and Warnings...................... 2 Overview, Standard & Optional Features........3 Catalog Number System.................... 3 Other Options............................
More informationConquest Remote Control Monitor System
Conquest Remote Control Monitor System The Conquest Electric Remote Controlled Monitor System is ideal for use in industrial fire suppression, vapor mitigation, and other fixed site applications. In addition,
More informationDescription. Construction
LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)
More informationFDJ SERIES Jockey Pump Controllers Features
1-1 NEMA 2 Enclosures Enclosures have an oven baked powder paint finish and are supplied with NEMA 2 rating, unless otherwise ordered. Available options include: NEMA 1, 3R,, X, 12. Note: NEMA, X enclosures
More informationWiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz
Wiring Diagrams 38ARZ007-012 38ARS008-012 38ARD012-024 Air-Cooled Condensing Units 50/60 Hz UNIT 38AR DIAGRAM INDEX VOLTAGE-PHASE-HERTZ LABEL DIAGRAM FIGURE NO. 208/230-3-60 38AK540117 1 or 2* 400/460-3-50/60
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationGuide Specification Model CTG Automatic Transfer Switch
Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production
More informationKUH. Horizontal Unit Heater. Applications. Description
KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)
More informationCALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.
CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. NAME OF TENDER: CONSTRUCT, DELIVER AND COMMISSION 3 (THREE) LIFT STATION ELECTRICAL LOCATION OF WORK: 3 Separate work sites in
More informationMASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page
More informationElectrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts
Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the
More informationInstruction Manual Model A
706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED
More informationULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S
ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S Applications Aircraft Hangars/Service Areas hemical Storage/Handling Areas oal Preparation Plants ompressor Stations Grain Elevators Oil Refineries
More informationTECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS
TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationQ7800H Integrated Burner Control Subpanel
Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications.
More information1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.
PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 REFERENCES... 2 1.4 DEFINITIONS... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 3 1.7 COORDINATION... 3 1.8 DELIVERY, STORAGE, AND
More informationMODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL
MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL TABLE OF CONTENTS Product Overview... 2 Operation... 3 Installation... 5 Troubleshooting... 9 Ordering Information, Warranty and Service...10
More informationMARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID
CABINET SHEET METAL (OUTER PANELS) 1 CABINET SHEET METAL (OUTER PANELS) 1 2 Left Side Door, Includes Exterior Panel and Perforated Interior Panel Right Side Door, Includes Exterior Panel and Perforated
More informationTHE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!
THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR ON ALL CATALOG ORDERS! TABLE OF CONTENTS SYSTEM MONITORING DEVICES Plug-In Pedestal Alarm System... 4 High
More informationCIRCUIT BREAKER UNIT ENCLOSURES 10,000/25,000 AMPERES INTERRUPTING CAPACITY. UPC Code. Catalog Number
CIRCUIT BREAKER UNIT ENCLOSURES 10,000/25,000 AMPERES INTERRUPTING CAPACITY Circuit Breaker Unit Enclosures TABLE 2-14. CIRCUIT BREAKER UNIT ENCLOSURES Main Circuit Breaker Unit Enclosure Encl. Flush Cover
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationExplosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes
Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes Part #: EPS-PB10-MS-AT-V3 Made in the USA The Larson Electronics EPS-PB10-MS-AT-V2 Explosion Proof Push
More information1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.
WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.
More informationRemote Alarm Panels Features
Features 1-1 DFDAP-M / FDAP-M Remote Product Description Eaton s Remote s are designed to provide audible and visual alarms for Electric and Diesel Fire Pump Controllers. These remote panels are located
More informationSIMPLEX WEATHERPROOF CONTROL PANELS
TECHNICAL BROCHURE BCP3 R10 FEATURES Rugged, NEMA 4X construction withstands even the most severe weather con ditions and prevents corrosion. Solid-state control board displays float status for ease of
More informationSeries P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC9713 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationFTA550 JOCKEY PUMP CONTROLLERS
FTA550 JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP550E (A) FTA550E XG Jockey Pump Controllers Product Description Failed to start indication Main switch not in Auto alarm Pressure recording
More informationSC-LLC-200 LEAD/LAG CONTROLLER INSTALLATION INSTRUCTIONS
LEAD/LA CONTOLLE INSTALLATION INSTUCTIONS INTODUCTION The from Specified Controls is a versatile, AC powered lead/lag controller offering true dual stage control to balance the operating run time between
More informationDomestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.
Cast Iron Receivers: For years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Each Receiver comes standard with Inlet connection, an overflow and
More informationFT60 Reduced Voltage - Autotransformer
1-1 Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer
More informationSprecher + Schuh Motor Control and Protection Products
Sprecher + Schuh Motor Control and Protection Products oil and gas pumping, irrigation and piping elevator and hydraulic lifts food processing We consistently work on improving our products and processes
More informationJr. Tech (JT-1, 2, 3) Knowledge Areas
Jr. Tech (JT-1, 2, 3) Knowledge Areas The Jr. Tech Level includes technicians that are just entering the business and are in the beginning stages of their HVAC-R training and development. Over this period
More informationModel GPT 3 Freeze Protection Thermostat
We manage heat Model GPT 3 Freeze Protection Thermostat Part Number 19425 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202
More informationYOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.
Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters
More informationSECTION LIGHTING
SECTION 26 50 00 LIGHTING PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and required to furnish and install
More informationMPT Electric Fire Pump Controller
MPT Electric Fire Pump Controller Alarm Messages and Guide This manual provides alarm descriptions, troubleshooting steps, and alarm set point configuration information for Metron MPT Fire Pump Controllers
More informationFTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE
FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP550F (A) FTA550F XG Jockey Pump Controllers Product Description Description Firetrol FTA550F XG Jockey Pump Controllers are intended for use
More informationPower Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses
BCU Power Supplies Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses Installation, Commissioning and Operating Manual BCU RANGE OF
More informationCustom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2
The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer
More informationModel VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch
Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional
More informationSECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL
SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationNational Electrical Code
National Electrical Code 409.30 Disconnecting Means Disconnecting means that supply motor loads shall comply with Part IX of Article 30. 410.81 Control (A) Disconnection Luminaires (fixtures) or lamp installation
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationFTA200-A REMOTE ALARM PANEL
FTA200-A REMOTE ALARM PANEL (FOR USE WITH ELECTRIC FIRE PUMP CONTROLLERS) STANDARD SUBMITTAL PACKAGE SBP200A FTA200-A Remote Alarm Panels for Electric Fire Pump Controllers Product Description Type A -
More informationCONTENTS AUTOMATIC TRANSFER SWITCHES
CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training
More informationInstallation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control
More informationPS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option
Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR
More informationPowers Controls Low Temperature Detection Thermostat
Document No. 155-016P25 ET 134-22 Rev. 1, February, 2000 Powers Controls Low Temperature Detection Thermostat Description The electric Low Temperature Detection Cut-out and Alarm Thermostat is a remote
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 83 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-15768N (September 1999) UNIFIED FACILITIES GUIDE
More informationSUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)
SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) PART 1 GENERAL 1.01 Scope Furnish and install manual transfer switches (3MTS) with number of poles, amperage, voltage, and withstand
More informationMODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES
MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES INDEPENDENT ZONE ANNUNCIATION WITH ZONE STATUS INDICATION EIGHT RED LEDS INDICATE ZONE STATUS SELECTABLE NORMALLY-OPEN,
More informationFax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE
Phone (724) 528-9559 Cimco Electronics, Inc. Fax (724) 528-1108 26 Main St.; P. O. Box 248 West Middlesex, PA 16159 Oct., 2002 IMPORTANT NOTICE Dear Customer, We would like to make you aware of a few hardware