Macerator Pumps & Lifting Station. Technical presentation Part 1
|
|
- Meryl Cain
- 5 years ago
- Views:
Transcription
1 Macerator Pumps & Lifting Station Technical presentation Part 1
2 Index Brief history and product background. Product range & characteristics. Benchmarking with SFA range Installation & Servicing
3 History & Product Background The first model was launched in It incorporated a revolutionary characteristics which created market trend. Smooth design instead of the shoe box concept offered by the competitors. vs
4 History & Product Background Easy to use (just flush the toilet) - all the operation is automatic. Easy to maintain - the cassette concept, allows accessing to the unit s engine WITHOUT moving the toilet and all the units connected to the macerator. Easy and straightforward to repair.
5 History & Product Background A second model, more compact. Pumping station followed shortly after.
6 Product Range Install it anywhere. Just select the inlets you need and the pumping height you require.
7 The complete product range here: Product Range
8 Product Range Choose one depending on your needs. WC Basin Shower Bidet Sink Dish washer Washing machine
9 Product Characteristics 6 m 23 l/min 5 m 23 l/min 7 m 23 l/min Lucia di Piave, 24th November 2011
10 Product Characteristics Sanitary Macerator. 1 WC inlet, 2 bottom side inlets (1 ½ ) Compatible with wash basins, shower trays & bath tubs. 1 vertical outlet (25mm PN15), with non-return valve, suitable for PVC pipes. Pumping capacity: 6 m (vertical) or 62 m (horizontal). 95 l/min (2m)- 23 l/min (6m). EN certified product. Power: 600 W. 230 V (AC). 50 Hz. Max operating temperature: 50 ºC. Eccentric pan connector included (EN33/37).
11 Product Characteristics
12 Vertical distance Product Characteristics Up to 2 m Up to 12 m Up to 22 m Up to 32 m Up to 42 m Up to 52 m Up to 62 m Horizontal distance
13 Product Characteristics Compact Sanitary Macerator. 1 WC inlet, 1 bottom right side inlet 1 ½ Compatible with wash basins. 1 vertical outlet (25mm PN15), with non-return valve, suitable for PVC pipes. Pumping capacity: 5 m (vertical) or 52 m (horizontal). 85 l/min (2m)- 23 l/min (5m). EN certified product. Power: 500 W. 230 V (AC). 50 Hz. Max operating temperature: 50 ºC. Eccentric pan connector included (EN33/37).
14 Ø25mm PN15 Product Characteristics
15 Product Characteristics
16 Product Characteristics Lifting Station 2 top inlets (1 ½ ), 3 side inlets (two at the bottom) Compatible with wash basins, shower trays & bath tubs. 1 vertical outlet (25mm PN15), with non-return valve suitable for PVC pipes. Pumping capacity: 5 m (vertical) or 52 m (horizontal). 85 l/min (2m)- 23 l/min (5m). EN certified product. Power: 500 W. 230 V (AC). 50 Hz. Max operating temperature: 50 ºC.
17 Ø25mm PN15 Product Characteristics
18 Product Characteristics
19 Benchmarking with SFA Equivalent product per application. 5m 52m 5m 52m 6m 62m 7m 72m 7m 72m 7m 72m
20 Benchmarking with SFA Per product: Wall separation 217 mm 227 mm Engine system Submerged Clean in casset system Max. pumping 5 m vertical 5 m vertical height / distance 100 m horizontal 52 m horizontal Motor (W) 400 W 470 W Weight 5.4 Kg 7.95 Kg Start/Stop system Pressure switch Pressure switch Water protection IP44 IP44 Inlet /s Pan connector Pan connector & 40 mm inlet (with joints) Outlet Ø23/32 mm 25mm PN15 Noise level N/S 72 dba Application use Toilet Toilet & washbasin.
21 Benchmarking with SFA Per product: Wall separation 217 mm 227 mm Engine system Submerged Clean in casset system Max. pumping 5 m vertical 5 m vertical height / distance 100 m horizontal 52 m horizontal Motor (W) 400 W 470 W Weight 5.4 Kg 7.95 Kg Start/Stop system Pressure switch Pressure switch Water protection IP44 IP44 Inlet /s Pan connector & Pan connector & 40 mm 40 mm top inlet. side bottom inlet. Outlet Ø23/32 mm 25mm PN15 Noise level N/S 72 dba Application use Toilet & washbasin. Toilet & washbasin.
22 Benchmarking with SFA Per product: Wall separation 204 mm 217 mm Engine system Submerged Clean in casset system Max. pumping 7 m vertical 6 m vertical height / distance 110 m horizontal 62 m horizontal Motor (W) 1100 W 550 W Weight 10.0 Kg 10.8 Kg Start/Stop system Pressure switch Pressure switch Water protection IP44 IP44 Inlet /s Pan connector, 1 Ø40 Pan connector & 2 Ø40 mm top, 2 Ø40 mm 40 mm side low inlets. side low inlets. Outlet Ø22/28/32 mm 25mm PN15 Noise level N/S 68 dba Application use Toilet, washbasin, Toilet, washbasin, shower tray, bide. shower tray, bide.
23 Benchmarking with SFA Per product: Size (w/h/t) mm 295/145/ /270.5/180 Engine system Submerged Clean in casset system Max. pumping 4 m vertical 7 m vertical height / distance 40 m horizontal 72 m horizontal Motor (W) 250 W 390 W Weight 3.5 Kg 7.6 Kg Start/Stop system Pressure switch Pressure switch Water protection IP44 IP44 Inlet /s 2 Ø40/32 side inlets. 2 Ø40 top inlets 3 Ø40 side inlets Outlet Ø32 mm 25mm PN15 Noise level N/S 64 dba Application use washbasin, washbasin, washing shower tray, bide. machine, shower tray, bide, dish washer, sink
24 Benchmarking with SFA Per product: Size (w/h/t) mm 375/276/ /270.5/180 Engine system Submerged Clean in casset system Max. pumping 5 m vertical 7 m vertical height / distance 50 m horizontal 72 m horizontal Motor (W) 400 W 390 W Weight 6.3 Kg 7.6 Kg Start/Stop system Pressure switch Pressure switch Water protection IP44 IP44 Inlet /s (mm) 2 Ø40 top inlets. 2 Ø40 top inlets 2 Ø40 side inlets 3 Ø40 side inlets Outlet Ø32 mm 25mm PN15 Noise level N/S 64 dba Application use washbasin, washing washbasin, washing machine, shower tray, machine, shower tray, bide, dish washer, bide, dish washer, sink, sink, bathtub. bathtub.
25 Benchmarking with SFA Per product: Size (w/h/t) mm 375/276/ /270.5/180 Engine system Submerged Clean in casset system Max. pumping 7 m vertical 7 m vertical height / distance 70 m horizontal 72 m horizontal Motor (W) 400 W 390 W Weight 6.4 Kg 7.6 Kg Start/Stop system Pressure switch Pressure switch Water protection IP44 IP44 Inlet /s (mm) 2 Ø40 top inlets. 2 Ø40 top inlets 2 Ø40 side inlets 3 Ø40 side inlets Outlet Ø32 mm 25mm PN15 Noise level N/S 64 dba Application use washbasin, washing washbasin, washing machine, shower tray, machine, shower tray, bide, dish washer, bide, dish washer, sink, industrial sink, bathtub. bathtub.
26 Installation Guide Installation video: [Play the video here]
27 Installation Guide Main tips: Always pump first the vertical gap and later the horizontal Connected sanitary appliances do not need a trap Installing a nonreturn valve is a must. Lateral inlets must come from a 1-2% sloped pipe
28 Installation Guide Main tips: When a shower tray or a bathtub is installed minimum height must be respected, otherwise waste water may appear onto the shower enclosure. Ensure that lateral inlets equipped with the non-return valve are correctly assembled (NRV flap opens towards the unit).
29 Installation Guide Main tips: Ensure when installing the outlet pipe that no glue falls inside the NRV, this could cause malfunction as it may not operate (open and/or close) properly. When assembling a toilet ensure the pan connector correctly fits into the toilet spigot and the macerator unit without leakage. Ensure once the toilet is installed that the unit stands perfectly onto the floor and does not hang from the outlet.
30 Installation Guide Main tips: Always ensure there is a minimum gap of 22 cm in the installation above the unit to allow access for maintenance. Ensure the macerator is not concealed behind a wall or at a different level from the wc which might prevent its easier access.
31 Installation Guide Main tips: Prevent the installation of 90º elbows on the outlet running pipe, use 45º instead. Install a vac-valve if the unit pumps water to a collector pipe below ground level. Washing machines, dish washer machines or other units equipped with pump must not be connected unless specified to a macerator. (Except CICLON LS, where its use is allowed) Pipe must only run vertical (straight) or horizontal (with a 1-2% slope).
32 Normal operation does not require any specific maintenance. Maintenance Guide
33 Maintenance Guide Fast access to all the electrical & mechanical parts which might require servicing. Avoid disassembling all the pipe connections and the toilet screws to the floor which are normally corroded. Easy access from the left side of a toilet. One screw away from accessing to the motor, capacitor, pressure switch, triac and wiring parts.
34 Maintenance Guide Required tools Screw driver Hand made tool (to position the pressure switch pipe). Hand made pliers (to help securing the security ring to the pressure switch). Protection gloves Procedure Always ensure the unit is disconnected from the power supply and close the water supply prior to any operation. To prevent any damage always extract the cassette unit from its enclosure before operating any component (motor, pressure switch, capacitor). Gloves are recommended when operating into the wet part to prevent accidental cuttings with the product sharp blades.
35 Maintenance Guide Electrical wiring BROWN BLACK BLUE BROWN All the connections are faston equipped.
36 Maintenance Guide Cassette access top view Cassette access bottom Capacitor & TRIAC Motor Motor impeller External blade Pressure switch All the electrical parts which might need servicing are here. Pressure switch measuring point In case of blockage, servicing access should be made here.
37 Maintenance Guide Pressure switch top view Capacitor & Triac Pos. 1 To cable (brown) Pos. G To cable (black) Unused Pos. 3 To cable (black) Pos. A2. Double faston. To cable (brown) Pos.A1. To cable (brown) Pressure switch measuring point All the pressure switch come factory regulated and must not be touched. Blue (for macerators) or Red (for lifting stations) screw identified. Capacitor and pressure switch come with faston for easier assembly.
38 Spare parts (CICLON L) Maintenance Guide
39 Spare parts (CICLON XS) Maintenance Guide
40 Spare parts (CICLON LS) Maintenance Guide
41 Troubleshooting
42 Maintenance Guide User has to identify the product as a CICLON Might happen in 1% of calls that product is not Ciclon product. Product serial number has to be sent to us & proof of purchase. Dux Ciclon Service Agent is asked to attend the repair. Repair report has to be sent by the Service agent to Dux NZ. For customer service follow-up. Dux offers a 2 year warranty for all its sanitary macerators & lifting stations. This warranty includes all manufacturing product failures, covering the cost of spare parts, labor costs and transport, but does not include any costs when failures are caused by installation or user.
43 Maintenance Guide Typical product failures: Improper use. Toilet used to evacuate elements which block the motor. Inadequate installation. Product installed not according to installation manual or using it for un-approved applications. Product failure. Electrical or mechanical failure.
44 Maintenance Guide How-to Macerator will not start Macerator works, does not discharge or discharges slowly. Macerator does not stop. Electrical supply Thermotrip motor protection Outlet pipe or unit blocked. Outlet pipe too high or too long. The outlet pipework is restricted The internal pressure switch has failed. Check wiring / switches / Fuse / Circuit breaker Wait 20 min (aprox). If you hear a buzz without further movement pump might be blocked. Cassette disassembly required for servicing. Cassette disassembly required for servicing. Clean the outlet pipe and/or the NRV. Extract the complete cassette before replacing the pressure switch.
45 Maintenance Guide How-to The motor buzzes, but does not spin. After use, the macerator hunts on and off. Pump is blocked. Water loss from WC or auxiliary connections. Outlet NRV leaking. Cassette must be extracted, bottom blades should be cleaned. Fix leakages from WC or auxiliary connections. Clean or replace NRV. The macerator works with the WC but not with the auxiliary connections. Accumulation of waste inside the WC after flushing Lateral inlet pipework blocked Inadequate water volume in the cistern Clean the lateral inlet pipe or the NRV. Adjust water level in cistern (6 litres minimum)
46 Maintenance Guide How-to Water returns to the shower tray or bathtub Minimum fall for the inlet pipe has not been met. The inlet non-return valve blocked. Pressure switch malfunction Correct installation. 18 cm height under the shower tray is required. Clean NRV. Replace the pressure switch Odd noises when macerator operates. Obstruction due to foreign object Water absorbed as the outlet pipe end discharges at a lower height than the unit s installation. Extract the cassette unit, remove foreign object. Change installation or install a vac-valve at the highest point of the installation. Nasty smells from the macerator. Active carbon filter need replacing. Replace the filter.
47 Maintenance Guide User caused typical failure issues: Blade s jam due to inappropriate toilet use. (1) Macerator used with sinks, washing machines, dishwashers. (2). Use of inadequate cleaning products. (3) (1) (3) Blades must be accessed un-screwing and removing all elements causing blockage.
48 Maintenance Guide Installer caused typical failure issues: Concealed product installation (In-wall). (1). Shower tray height from ground lower than required (18 cm). (4) Inadequate outlet pipe (other than 25mm PN15) use. (2) Vertical non-return valve glued in excess, thus avoiding to close/open, or not installed. Exceeded maximum pumping distances. (2) Inadequate application use of product (3) (1) (3) (1) (4) Faulty installations must be changed to avoid these failures. (2)
49 Maintenance Guide Installer caused typical failure issues: Faulty installations must be changed to avoid these failures.
50 Servicing
51 Maintenance Guide Step by Step product disassembly. To replace the pressure switch and pipe, the cassette unit must be accessed. Unplug from power line before any further action. Remove hub cap & unscrew cassette cover.
52 Maintenance Guide Step by Step product disassembly. All the products must be installed with a 22 cm free top area to allow the cassette disassembly. Bolts to enable easier casset extraction
53 Maintenance Guide Step by Step product disassembly. Remove cassette cover. Remove motor ventilation casing and any other electrical component which may interfere on accessing silicone pressure switch pipe.
54 Maintenance Guide Step by Step product disassembly. If hose rework needs to be done on installed products, this rework must be done with cassette out from product s body. Proceeding this way, it will prevent water on products body accessing inside cassette when removing silicone pressure switch pipe.
55 Maintenance Guide Replacing the vertical NRV It s advisable to pump clean water into the pipe before replacing or checking the non-return valve. Remove fixation clip. Remove 1 1/4 nut. Non-return valve joint. A recipient to collect all the water coming from the vertical pipe should be prepared.
56 Visit us at
WC2 & WC3 Installation & Maintenance Instructions
WC2 & WC3 Installation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information WC3 shown WC2 WC3 IMPORTANT
More informationSanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.
1. escription Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan. I The Sanipack will pump away the waste from a WC, washbasin and shower.
More informationGRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS
More informationGreenleaf 600 Macerator Toilet Waste Pump
Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations.
More informationThe easy solution for waste water removal
The easy solution for waste water removal Wasteflo products provide a solution for waste water removal in a variety of environments. Full technical data sheets are available to download www.stuart-turner.co.uk
More informationThe new SOLOLIFT2 means goodbye to dirty hands
The new means goodbye to dirty hands The new is generations ahead Compact lifting stations have suffered a bad reputation, but the new generation is here! Combining innovation with modern comfort, Grundfos
More informationPlease also see 10 golden rules for correct Saniflo installation on
1. Description Sanichasse is a WC-suite with a 6 litre flush and built-in pump macerator. Handwash-basin and shower can also be connected. However the inlet is at the back of the machine which may require
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST BE READ BEFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAVE ALL PAPERWORK WITH CLIENT
More informationSUPPLEMENTARY INSTRUCTIONS
www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate
More informationGreenleaf 400 Macerator Toilet Waste Pump Instruction Manual
Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz greenleaftraders@gmail.com Greenleaf 400 Macerator Toilet Waste Pump Introduction The Greenleaf
More informationSOLOLIFT2. Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust
Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust - GET INTRODUCED TO A NEW GENERATION Up until now, macerators have
More informationInstallation. Please keep this manual for future reference.
Installation Tecma Bathroom Anywhere Owner s and Installation Manual Please keep this manual for future reference. Read ALL these instructions before installing the Tecma Bathroom Anywhere unit. Warning
More information1. Description. 2. List of Accessories included
1. Description This unit is a pump that will clear the waste from a shower and washbasin, bath, washing machine, glass washer and a sink in a light commercial situation. The unit will start automatically.
More informationInstallation Systems. Safety and durability
Installation Systems Safety and durability Installation Systems Safety and durability Wide range of solutions Duplo WC Compact With Roca s Duplo systems you obtain all the installation flexibility for
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST E READ EFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAvE ALL PAPERWORK WITH CLIENT
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationSUBMERSIBLE DIRTY WATER PUMP
SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP100A, DWP150A, DWP200A PART NO: 7230098, 7230099, 7230100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117 - ISS 2 INTRODUCTION Thank you for
More informationDOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION
DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION Hot and Cold water distribution pipework Sizing of pipework For everyday plumbing in an average sized building a rule of thumb can be used when
More informationBlitz Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Blitz Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading taps
More informationThermostatic Bar Valves
Thermostatic Bar Valves Installation & operating guide Please leave this installation & user guide with the end user CONTENTS 1. Product Variants 1 2. Important information 2 3. Cleaning & Aftercare 3
More informationHOME INSPECTION CHECKLIST
HOME INSPECTION CHECKLIST Date: Page 1 of 9 Client Name: Address: Tel No: Surname: Email: A WATER METER 1 Is the water meter visible YES NO 2 Water meter registers when water is drawn YES NO 3 Water meter
More informationDOUBLE DISHDRAWER TM DISHWASHER
DOUBLE DISHDRAWER TM DISHWASHER DD60DA & DD60DC models INSTALLATION GUIDE NZ AU GB IE 591151C 08.17 WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the
More informationInstallation Instructions
Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL
More informationGRUNDFOS SOLOLIFT2 GRUNDFOS SOLOLIFT2 ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET.
GRUNDFOS The Perfect Fit GRUNDFOS ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET. 800 POINTS INTRODUCTION - GET INTRODUCED TO A NEW GENERATION
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationGroup SANIFLO. The solution to install a WC, a bathroom or a kitchen anywhere you want MADE IN FRANCE
Group SANIFLO The solution to install a WC, a bathroom or a kitchen anywhere you want MADE IN FRANCE CONTENTS I I SFA INFORMATION AND BENEFITS MACERATOR AND GRINDER 7 MACERATORS 8 I 9 I I I I I I 5 I I
More informationDishwasher Installation Instructions DW 24XT/DW 24XV
Dishwasher Installation Instructions DW 24XT/DW 24XV Installation Instructions Dishwasher BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Observe all governing codes and ordinances.
More informationAUTOMATIC ICE-CUBE MAKER
AUTOMATIC ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having chosen
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TM DishDrawer dishwasher DD90SDF(H)TX, DD90SDFTM (Designer) & DD90S(H)TI (Integrated) models NZ AU GB IE 5900D 04.3 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL Designer
More informationAUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS
AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased
More informationSmarter. Easier. Faster. Product Guide
Smarter. Easier. Faster. Product Guide Intelligent plumbing solutions that allow you to add the luxury of additional wet facilities anywhere you choose 1. OVER 50 YEARS OF EXPERTISE The Saniflo Group as
More informationMODULAR AUTOMATIC GRANULAR ICE FLAKER
MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationHEAT RECOVERY AIR HANDLING UNIT
HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AN CARE INSTRUCTIONS THESE INSTRUCTIONS MUST BE REA BEFORE INSTALLATION IS ATTEMPTE. FAILURE TO O SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAVE ALL PAPERWORK WITH CLIENT
More informationSmile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Smile Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading taps
More informationINSTALLATION GUIDE NZ AU C
DISHWASHER DW60 models INSTALLATION GUIDE NZ AU 591217C 12.17 1 SAFETY AND WARNINGS! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker.
More informationFood Waste Disposer Instruction Manual
Food Waste Disposer Instruction Manual See insert for specific information about your new disposer NOTE: IMPORTANT: CAUTION: This Food Waste Disposer has been designed to operate on 110-120 Volt, 60 Hz
More informationSINGLE DISHDRAWER TM DISHWASHER
SINGLE DISHDRAWER TM DISHWASHER DD4SA & DD4SCT models INSTALLATION GUIDE US CA 595B 08.7 SAFETY AND WARNINGS! WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or
More informationDOUBLE DISHDRAWER TM DISHWASHER
DOUBLE DISHDRAWER TM DISHWASHER DD4DDFT & DD4DVT models INSTALLATION GUIDE US CA 5985 A 08.7 SAFETY AND WARNINGS! WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse
More informationSHOWER SOFTENER-CEASA 1
SHOWER SOFTENER-CEASA 1 Application: The product is mainly used for shower water softening, but can also be used for floor heating, beauty salons, hairdressing salons, washing machines etc. The softener
More informationNEWS 2017 SANIFLO. Pumps and pumping stations
NEWS 2017 SANIFLO Pumps and pumping stations SFA, WORLD LEADER IN SANITARY FACILITIES MADE IN FRANCE For 60 years, the Société Française d Assainissement [French Sanitation Company] has worked on improving
More informationOval Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Oval Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading taps
More informationINSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET
INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 TEMPERATURE ALTERNATIVES 3 PACK CONTENTS 4 PRE-INSTALLATION INFO 5-6 FAUCET INSTALLATION 7 ADJUSTING
More informationModel Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION
PumpAgents.com - Click here for Pricing/Ordering Model 37045-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual function
More informatione Bath Fan with Light User s Guide
e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING
More informationHEAVY DUTY BRASS SHOWER PUMPS
HEAVY DUTY BRASS SHOWER PUMPS YOUR GUARANTEE IS AT RISK IF PUMP NOT INSTALLED CORRECTLY. SEE SECTION 2 IMPORTANT INSTRUCTIONS Performance Shower Products SERVICE HELPLINE TEL: 01883 730339 1. GENERAL Your
More informationDecade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Decade Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading taps
More informationSilent Venus SVP100. **Visit for how to install instruction videos**
Silent Venus SVP100 **Visit www.thesilentvenus.com/our-system for how to install instruction videos** This product must be installed in strict accordance with local plumbing codes. A licensed plumber should
More informationUnpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply
11 INSTALLATION Installation Overview Choosing the proper location Unpacking and removing shipping bolts Connecting the water line Connecting the drain line Leveling the washer Connecting to the power
More informationVENTILATION FAN WITH LIGHT AND HEATER
VENTILATION FAN WITH LIGHT AND HEATER MODEL RAD80L TABLE OF CONTENTS Package Contents Important Instructions 3 Preparation 4 Assembly Instructions 6 Wiring Instructions 10 Operating Instructions 10 Care
More informationAtmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors
Atmos EasySolar Installation Instructions for Atmos EasySolar In-roof and flat roof installation with flat plate collectors Atmos Heating Systems West March Daventry Northants, NN11 4SA Tel: 01327 871990
More informationPLUMBING INSTALLATIONS
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...
More informationMODEL E
www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationplumbing for greywater
plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of
More informationEVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.
Date: 25 Jan 2005 Doc. 1:114E TECHNICAL DATA 5979301 EVAC 90, SQUATTING To main vacuum line, connection Ø50 Service door 600 Push button Fresh water supply connection 1/2" MPT BSP 700 700 Flushing mechanism
More informationManual / Handbuch Spare parts list / Ersatzteilliste
Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a
More informationOPERATION & MAINTENANCE INSTRUCTIONS
SUBMERSIBLE PUMPS MODEL NO: PSV3A, PSV4A, PSSV2A & PVP11A PART NO: 7236042, 7236044, 7236050 & 7236060 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC07/17 iss 4 INTRODUCTION Thank you for
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TM DishDrawer dishwasher DD4D 7 & DD4DT 7 models US CA 59004D 04.3 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL STANDARD HEIGHT DOUBLE MODELS TALL HEIGHT DOUBLE MODELS
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationInstallation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control
manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:
More informationStuart Turner has an engineering heritage dating back to 1906 and continues to manufacture from its original site
115 Pump Solutions - From Showers to Whole House Stuart Turner has an engineering heritage dating back to 1906 and continues to manufacture from its original site in Henley-on-Thames. With an unrivalled
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TM DishDrawer dishwasher DD36SDFTX (Designer) & DD36STI (Integrated) models US CA 59008D 04.3 a SAFETY AND WARNINGS Electrical hazard WARNING! Before installing the dishwasher,
More informationKQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800
KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal
More informatione Bath Fan with Light User s Guide
e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY
More informationIssue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation
Issue 4 Oct 2005 Panamatic Top loading Maxi & Optima 3 Installation Please Do handle the unit with care, to avoid scuffs and scratches during installation. Do not over-tighten plumbing or any other mechanical
More informationWALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding
More informationCRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS DishDrawer TM dishwasher DD24SUT7 and DD24SVT7 models US CA 590225B 04.4 SAFETY AND WARNINGS Electrical hazard WARNING! Before installing the dishwasher, remove the house fuse
More informationThermostatic Concealed Shower Valve
Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve
More informationModel T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP
Model T00405 REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 450331 Strainer 2 450332 Oil cover "O" ring 3 400447 Impeller 4 450333 Pump casing 5 400450 Oil cover 6 400449 Oil seal 7 400448
More informationCRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE
No. 9195 CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2007. All rights reserved. No part of this publication may be reproduced by any means without
More informationGrohtherm Wireless! Installation Instructions Pumped
36 022 Pumped Grohtherm Wireless! Grohtherm Wireless! GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 RUS CN...26 Installation Instructions F...3
More informationOWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models
OWNER S GUIDE Electric and Gas Storage Water Heaters Safety Information Owner s Information Warranty Models Electric Storage Water Heaters: 25THMS124P 25THMS136 50THMS124P 50THMS136 80THM136 125THM118
More informationUSER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit
USER MANUAL Frigate HRV 120 SR Frigate ERV 120 SR Heat (energy) recovery ventilation unit 2 CONTENTS Safety requirements... 3 Introduction... 5 Use... 5 Included in the box... 5 Designation key... 5 Technical
More informationX1 series Submersible Drainage Pump
X1 series Submersible Drainage Pump 50HZ STAIRS INDUSTRIAL CO., LTD. X1 SERIES - Submersible Pump Model code X1-03 M A - 32 Discharge size A =Float switch S =Vertical level switch M = Single Phase T =
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TM DishDrawer dishwasher DD4S 7 & DD4ST 7 models US CA 59004D 04.3 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL STANDARD HEIGHT SINGLE MODELS TALL HEIGHT SINGLE MODELS
More information6000, 8000, & 15000
aquaforce 2823 1583 1584 1585 1586 6000, 8000, 12000 & 15000 Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0) 121 313 1122 info@hozelock.com www.hozelock.com 43386-000? 1 A A. Wildlife
More informationTIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL
TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6
More informationTop Control Dishwasher
INSTALLATION GUIDE Top Control Dishwasher NS-DWH2BS8/NS-DWH2SS8/NS-DWR2BS8/NS-DWR2WH8/NS-DWR2SS8 Before using your new product, please read these instructions to prevent any damage. Contents Introduction......................................................................................................
More informationINSTALLATION GUIDE NZ AU
DISHWASHER DW60U6I & DW60U2I models INSTALLATION GUIDE NZ AU 1 SAFETY AND WARNINGS 100 lb 45 kg! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit
More informationTelo Shower Mixing Valve TL10016CP
Telo Shower Mixing Valve TL10016CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility
More informationVADA - Rain2Main Automatic Rainwater Controller
PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden
More informationAUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM
AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear
More informationFAULT FINDING. Water Gas Cassette Toilet FAULT FINDING
Water... 208 Gas... 210 Cassette Toilet... 211 207 WATER FAULTS Water Fault Cause Remedy Water not flowing from any tap when operated but pump runs Pump does not run Water flows from cold tap but not from
More informationEFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres
EFX 600 aquamanta TM the experts in aquatic technology >600 Litres Coldwater Tropical Marine 4year guarantee Instruction Manual Important Safeguards This appliance is not intended for use by persons (including
More informationFOOD WASTE DISPOSER OWNER S GUIDE
FOOD WASTE DISPOSER OWNER S GUIDE See insert for specific information about your new disposer NOTE: IMPORTANT: CAUTION: This Food Waste Disposer has been designed to operate on 110~120 Volt, 60 Hz exclusively.
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationThe Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION
The Marine Throne "all the comforts of home" Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual
More information5700-E Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationSelf-help Temperature Adjustment
Self-help Temperature Adjustment The Shower Valve temperature is pre-set to 42 C, but on certain installations the temperature may need to be adjusted. Note: The hot water supply must be above 60 C. Turn
More information#PSBTWE1000 INSTALLATION GUIDE
Electronic Bidet with Integrated Toilet #PSBTWE1000 INSTALLATION GUIDE INSTALLATION MANUAL Thank you for choosing our product! Please read and carefully follow the instructions before installation. Secure
More informationInstallation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents
Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information
More informationREGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE
No. 9195 REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2011. All rights reserved. No part of this publication may be reproduced
More informationSPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC
APPLICATION GUIDE CHILLED WATER CASSETTE CWC - P/4P English/03-005 INDEX Index AGU CWC-P/4P General Description Specifications Performances tables Sound levels Options Dimensions Unit installation Electrical
More informationUser Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20
User Guide For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final Copyright 2014 Page of 20 1 Table of Contents 1 LOCATION & INFORMATION DIAGRAMS... 4 2 PURPOSE... 6 2.1 PROPER USAGE AND LIABILITY... 6 2.2
More informationArtisan Thermostatic Bath Filler
Artisan Thermostatic Bath Filler Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank you for choosing Bristan,
More informationJUNG PUMPEN LIFTING STATIONS
JUNG PUMPEN LIFTING STATIONS POWERFUL AND DEPENDABLE RESIDENTIAL TECHNOLOGY LIFTING STATIONS Product overview: Lifting stations the full range: Lifting stations are designed to dispose of wastewater in
More informationGeberit Assisted Toilet Pre-Installation Instructions
140mm Geberit Assisted Toilet Pre-Installation Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. All electrical connections are to be carried
More informationEnzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP
Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as
More informationGrohtherm Wireless! Installation Instructions Pumped High Pressure
36 022 Pumped Grohtherm Wireless! 36 023 High Pressure Grohtherm Wireless! GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 RUS...26 Installation
More information