1 ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram... Airflow Data... Accessories... Product Features heck flowrator for cooling and heat pump applications Direct drive, multi-speed EM blower motor All-aluminum evaporator coil oil mounting track for quick repositioning Optimized for use with R-0A refrigerant abinet air leakage less than.0% at.0 inch H₂O when tested in accordance with ASHRAE standard abinet air leakage less than.% at 0. inch H₂O when tested in accordance with ASHRAE standard kw kw electric heater kits AHRI certified; E listed Rigid SmartFrame cabinet Horizontal or vertical configuration capabilities depth for easier attic access DecaBDE-free thermoplastic drain pan with secondary drain connections Screw-less sides and back helps to reduce condensation when installed in humid locations Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grain-embossed finish Glue-less cabinet insulation retention Tool-less filter access * omplete warranty details available from your local dealer or at To receive the 0-Year Parts Limited Warranty, online registration must be completed within 0 days of installation. Online registration is not required in alifornia or Québec. SS-DASUF /A Supersedes /
2 Nomenclature A R U F B AA, 0, Brand Engineering * A - Single- Piece Air Handler Major/ Minor Revisions Unit Application - eiling Mount PS Motor R - Multi- Position PS Motor S - Multi- Position E Motor W - Wall Mount PS Motor abinet Finish U - Unpainted P - Painted N - Uncased Expansion Device F - Flowrator T - Expansion Valve *Not used for inventory management Refrigerant ompatability = R- 0A Electrical - 0/0 V, Phase, 0 Hz Nominal Width B - ½ Wide - Wide D - ½ Wide Nominal apacity Range = Tons = Tons = ½ Tons = ½ Tons = ½ Tons = Tons = Tons = Tons HKS X 0 X A AA Unit Type Major & Minor Revisions HKS - AH Heater Kit Phase ircuit Breaker A VA / Ø D VA / Ø X - - No circuit breaker B VA / Ø E VA / Ø - - ircuit Breaker - - 0/0 VA / Ø F - - 0/0 VA / Ø G VA / Ø kw kw - -. kw abinet Size (MAX) kw - -.kw w/0f limit - - abinet kW kw w/0f limit D - - D abinet kW kw X - - All abinet Sizes kw SS-DASUF
3 Product Specifications ASUF* ASUFD* Nominal Ratings ooling (Btu/h),000 0,000 Blower Diameter 0⅝" " Width 0⅝" 0⅝" oil onnections Liquid ⅜" ⅜" Suction ⅞" ⅞" oil Drain onnect (FPT) ¾" ¾" Electrical Data Voltage 0 / 0 0 / 0 Min ircuit Ampacity / / Max. Overcurrent Device (Amps) / / Minimum VA Maximum VA Blower Motor Full Load Amps (A).. Horsepower (HP) ¾ Ship Weight (Lbs.) Note: Minimum ircuit Ampacity (MA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed. SS-DASUF
4 Dimensions.0" (. cm)." (. cm)." (. cm) ".0" (. cm)." (. cm)." (. cm)." (. cm)." (. cm)." DRAIN PORT DETAIL." (.0 cm) B." (.0 cm)." (. cm)." (. cm)." (.0 cm)." (.0 cm) PLASTI EAKER OVER." (. cm) LOGO LOATION." (.cm) SUTION TUBE LIQUID LINE A G INLET TUBE SEE DRAIN PORT DETAIL H E D." (. cm) F INLET (FRONT VIEW)." (. cm) " (. cm)." (. cm) INLET (RIGHT SIDE VIEW)." (.0 cm) Model A B D E F G H ASUF* 0 0 ⅝ 0½ ⅜ ASUFD* ⅜ ½ ¾ ¾ ⅛ ¼ ⅜ SS-DASUF
5 Heat Kit Data Model ircuit ircuit Single-Point Kit Heater Amps MA¹ MOP² Heater Amps MA¹ MOP² MA¹ MOP² ASUFA 0 / 0 / / HKS*0X* 0. /. 0 / / HKS*0X*. / 0.0 / 0 / HKS*0X*. /.0 / / HKS*0X*. /. / / HKS*0X*. / / 0 / HKSXXF* 0/0 / / 0/. / 0/ HKSX0XF* 0/0 / / / / 0/ HKS*#*. / / 0 / 0. / 0 / / / 0 / 0 HKS#*. / / 0 / 0. / 0 / 0 / 0 / 0 00 / 0 HKSXF* 0/0 / / 0/. / 0/ HKS0XF* 0/0 / / / / 0/ ASUFDAD 0 / 0 / / HKS*0X* 0. /. / / HKS*0X*. / / 0 / HKS*0X*. /.0. / 0 0 / HKS*0X*. /. / 0 / HKS*0X*. / 0.0 / 0 / HKSXXF* 0/0 / / 0/. / 0/ HKSX0XF* 0/0 / / / / 0/ HKS*#*. / 0.0 / 0 / 0. / 0 / / / 0 / 0 HKS0D#*. /. / 0 / 0. / 0 / 0 / 0 / 0 00 / 0 HKSXF* 0/0 / / 0/. / 0 / HKS0XF* 0/0 / / / / 0 / HKSD* /0 / 0/0./0 /0 /0 / / 0 ¹ Minimum ircuit Ampacity (Heater Amps + Motor Amps) X. ² Maximum Overcurrent Protection =. X Motor Amps + Heater Amps ^ ircuit : Single-phase for Air Handlers ircuit : Three-phase for HKR Heater Kits * Revision level that may or may not be designated = ircuit Breaker Option --- indicates Not Required Heating kw orrection Factor Supply Voltage orrection Factor Multiply the 0-volt heating capacity by correction factors. SS-DASUF
6 HTR HTR HTR HTR HTR HTR HTR HTR HTR HTR M M M R M M M R M M M M R M M M M M R M R R M M M M L L L L L L ONE () ELENT ROWS TWO () ELENT ROWS THREE () ELENT ROWS FOUR () ELENT ROWS NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXEED MINIMUM OWER SPEED (MBS) SPEIFIED FOR THE AIRHANDLER/HEATER KIT OMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE.MARK AOING TO NUMBER OF HEATER ELENT ROWS INSTALLED. NO MARK NDIATES NO HEAT KIT INSTALLED. 0/0 VOLTS WIRING ODE FATORY WIRING USE OPPER WIRE EQUIPMENT OUND PLM G SEE NOTE R G W W Y Y O DH 0 L TR or R or or FUSE HOLDER (OPTIONAL) OR L G N Air Handler Wiring Diagram NOTE: The five element, kw heater kit is not shown above. L HIGH VOLTAGE LOW VOLTAGE FIELD WIRING LGN HIGH VOLTAGE LOW VOLTAGE R PLM PLM OLOR ODE SEE NOTE SEE NOTE ALTERNATE HEAT RELAY EEN RPLE OWN ITE AK RED YELLOW UE TR R A B OMPONENT ODE R ONTROL RELAY EVAPORATOR MOTOR FUSE LINK HTR HEAT ELENTS V P L M FUSE HOLDER (OPTIONAL) SEE NOTE FALE PLUG ONNETOR MALE PLUG ONNETOR PLM R G WW Y Y O DH V A B R RELAY TB TERMINAL BOA TR TRANSFORMER THERMAL LIMIT NOTES: OPPER POWER SUPPLY (USE RATING PLATE) USE MIN. FIELD WIRE 00A000-B ) RED WIRES TO BE ON TRANSFORMER TERMINAL "" FOR 0 VOLTS AND ON TERMINAL "" FOR 0 VOLTS. ) SEE OMPLETE WIRING DIAAMS IN INSTALLATION INSTRUTIONS FOR PROPER LOW VOLTAGE WIRING ONNETIONS. ) ONFIRM SPEED TAP SELETION IS APPROPRIATE FOR APPLIATION. IF SPEED TAP NEEDS TO BE HANGED, ONNET RPLE WIRE FROM TERMINAL OF R RELAY TO APPROPRIATE TAP AT TB ) OWN AND ITE WIRES ARE USED FOR HEAT KITS ONLY. ) FUSE: A, 0V, AG ARTRIDGE FUSE. IF REPLAENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSY IS NEESSARY, USE WIRE THAT ONFORMS TO THE NATIONAL ELETRI ODE. ALTERNATE HEAT RELAY High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. SS-DASUF
7 Five-Element Heater Kit Wiring Diagram HTR OMPONENT ODE OLOR ODE HTR HTR HTR HTR M M M M M M M M M0 M P R P = PIN ONNETOR HTR = HEATER ELENT = THERMAL LMT RS = RELAY/SEQUENER TB = TERMINAL OK B = IRUIT EAKER = ONTATOR = FUSE LINK = EVAPORATOR MOTOR EBTDR = ELE. OWER TIME DELAY R = RUN APAITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING ODE: HIGH VOLTAGE LOW VOLTAGE = AK = UE = OWN = EEN OR = ORANGE PK = PINK = RPLE = RED = ITE = YELLOW R R NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPEIFIED FOR THE AIRHANDLER / HEATER KIT OMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDIATES NO HEAT KIT INSTALLED. FIVE () ELENT ROWS B B B NOTE:- THIS LABEL MUST BE ATTAHED ON THE AIRHANDLER IN A PROMINENT LOATION L L L B L 00M00-A Three-Phase Heater Kit Wiring Diagram NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPEIFIED FOR THE AIRHANDLER/HEATER KIT OMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDIATES NO HEAT KIT INSTALLED. P TB L IRUIT PH 0-0V HTR L TR HTR L L GND L L IRUIT PH. 0-0V R T T T HTR M M RS M M PK EBTDR K XFMR-R XFMR- K SPEEDUP M SR R NO OM N NOTE:- THIS LABEL MUST BE ATTAHED ON THE AIRHANDLER IN A PROMINENT LOATION PK R AR POWER SUPPLY (IRUIT ) TR VOLT 0/0 VOLTS LOW M HIGH N NO EBTDR OM EBTDR L P W W W HKR POWER SUPPLY (IRUIT ) L L T T T HTR HTR M M HTR M M RS HEATER ONTROL OMPONENT ODE HTR HEAT ELENT EVAPORATOR MOTOR EBTDR ELE. OWER TIME DELAY RELAY RS RELAY/SEQUENER R RUN APAITOR THERMAL LIMIT TR TRANSFORMER TB TERMINAL OK ONTATOR P -PIN ONNETOR SR STRAIN RELIEF FUSE LINK B IRUIT EAKER WIRING ODE HIGH VOLTAGE LOW VOLTAGE OLOR ODE AK UE OWN EEN OR ORANGE PK PINK RPLE RED ITE YELLOW 00M00-A SS-DASUF
8 Airflow Data (Upflow Position) Model Number ASUF ASUFD Speed Tap Static Pressure (in w.c) ,0,,,0,0,,0,0,00 ---,,0,0,,0,,,,0 ---,,0,,,,0,0,, ---,,0,,,0,0,0,, ---,,,,,0,,0,, ---,,,00,,0,0,,,00,00,,,00,0,,,0,,,,0,0,,,0,,,0,0,0,00,00,,,0,,00,0,0,0,,0,0,0,00,00,0,0,,0 Notes The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. Use the FM adjustment factors of. for horizontal left,. for horizontal right &. for downflow orientations. Assumes dry coil with filter in place. All models are shipped from the factory with the speed tap set on T. Accessories Downflow Insulation Kit DPI-B DPI- DPI-D ASUF ASUFD Filters hassis Part# Size B ALFH0E.0" x 0.0" ALFH0E. x 0.0 D ALFH0E.0 x 0.0 Single-Point Kit ** Model HKR- HKR-0 HKR- SPW-0 X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any ARUF air handler as long as a compatible heat kit is installed in the unit. Our continuing commitment to quality products may mean a change in specifications without notice. 0 Houston, Texas Printed in the USA. SS-DASUF
ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons
ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting
More informationASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...
More informationASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...
More informationARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow
More informationARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor
Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal
More informationASUF Series. Multi-Position. Air Handler 1½ to 5 Tons
Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for
More informationARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor
Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat
More informationMBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features
M Multi-Position, Multi-Speed Modular Blower With PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat Kit Data...
More informationMBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features
M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5
More informationAVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...
More informationMBR. Multi-Position. Modular Blower
M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features
MBVC Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data...
More informationACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons
ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum
More informationAVPTC Multi-Position, Internal Txv
Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration
More informationAVPTC. Air Handler 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in
More informationDVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV
DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3
More informationDVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons
DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features
Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...
More informationTECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers
TECHNICAL MANUAL AL ARPT**4**, ARUF**4**, ASPT**4**, ASUF**4** Air Handlers Refer to Service Manual RS600006 for installation, operation & troubleshooting information. All safety information must be followed
More informationACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons
ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features
More informationAVPTC. Air Handlers 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion
More informationAEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7
Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed
More informationADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW
ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be
More informationACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons
ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum
More informationMBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h
MBV Variable-Speed, omfortnet - ompatible Modular Blowers ooling apacity: 8,000-60,000 BTU/h Standard Features ompatible with the omfortnet ommunication System family of products Variable-speed EM blower
More informationComfortNet -Compatible
GMV8 omfortnet -ompatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve
More informationGCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring
More informationGME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h
Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams...
More informationTECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)
TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationGCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring
More informationLRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS
Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged
More informationDM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h
Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...
More informationGMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams...
More informationINSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409
INSTALLATION MANUAL SINGLE PIEE AIR HANDLERS MODELS: F6FP018** - 060** ISO 9001 ertified Quality Management System SAFETY................................................ 1 SPEIFI SAFETY RULES AND PREAUTIONS...............
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications
More informationADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h
ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart
More informationGME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h
80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer
More informationAMVM97 (B) / ACVM97 (B)
(B) / (B) Heating Input: 60,000 0,000 BTU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 flow Specifications... 6 Wiring Diagram...
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409
TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal
More information80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h
Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to
More informationINSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209
INSTALLATION MANUAL SINGLE PIEE AIR HANDLERS MODELS: F*FP ISO 9001 ertified Quality Management System SAFETY................................................1 SPEIFI SAFETY RULES AND PREAUTIONS...............2
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationGMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationGMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationGMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationAEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton
AEPT SERIES Multi-Position Air Handler 2 to 5 Ton The AEPT multi-position air handler is approved for modular homes and may be installed in a utility room, closet, aclove, basement or attic. Standard Features
More informationGMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h
/ Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationGMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationTECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES
TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified
More informationSubmittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:
Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationSubmittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:
Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationSubmittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:
Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationMX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat
SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS
DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact
More informationMBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h
MB Cooling Capacity: 18,000-60,000 BTU/h Multi-Speed Modular Blowers Standard Features Multi-speed PSC blower motor Cooling or heat pump applications: upflow, downflow, and horizontal applications Control
More informationVariable Speed Convertible Air Handler 5 Ton
Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These
More informationTPLP Pre-Assembled. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION. Air & Electric Defrost
PRODUT DATA & INSTALLATION Bulletin T30--PDI-12 Part #1087152 PRODUT SUPPORT web: t-rp.com/tplp email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: Pre-Assembled Low Profile Evaporators Air & Electric
More informationPRODUCT SPECIFICATIONS
16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant
More informationVERTICAL MOUNT AIR HANDLERS
VERTICAL MOUNT AIR HANDLERS INSTALLATION INSTRUCTIONS 2005-2009 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com P/N: IO-281J
More informationINSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL
INSTALLATION MANUAL SINGLE PIEE VARIABLE SPEED AIR HANDLERS MODELS: AV*() SERIES ISO 9001 ertified Quality Management System GENERAL..............................................1 SAFETY................................................1
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation
More informationWAHL A Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,
More informationINSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC
INSTALLATION MANUAL SINGLE PAKAGE HEAT PUMP/ELETRI MODELS: PHE4 Series (2-5 Ton) LIST OF SETIONS GENERAL INFORMATION................................ 1 SAFETY...............................................
More informationINSTALLATION MANUAL SINGLE PIECE, 4 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL
INSTALLATION MANUAL SINGLE PIEE, POSITION EM AIR ANDLERS MODE: AV SERIES ISO 900 ertified Quality Management System GENERAL.............................................. SAFETY................................................
More informationAIR HANDLERS AIR HANDLERS
FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard
More informationMBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h
MB Multi-Speed Modular Blowers Cooling Capacity: 18,000-60,000 BTU/h Standard Features Multi-speed PSC blower motor Cooling or heat pump applications: upflow, downflow, and horizontal applications Control
More informationREPAIR PARTS. HKS Heater Kits
REPAIR PARTS HKS Heater Kits HKSC05XCAA HKSC08XCAA HKSC10XCAA HKSC15XAAA HKSC15XBAA HKSC19CAAA HKSC19CBAA HKSC20DAAA HKSC20DBAA HKSX03XCAA HKSX05XCAA HKSX06XCAA HKSX08XCAA HKSX10XCAA This manual is to
More informationINSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL
INSTALLATION MANUAL SINGLE PIEE, 3 POSITION EM AIR ANDLERS MODE: AV SERIES ISO 9001 ertified Quality Management System GENERAL..............................................1 SAFETY................................................1
More informationREM4P, REM4X. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with
More informationTECHNICAL SPECIFICATIONS B6VMMX
TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More informationAEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton
AEPT SERIES Multi-Position, Variable-Speed High-Efficiency Air Handler 2 and 5 Ton The AEPT air handler is compact for versatile upflow/downflow or horizontal multi-position installations and may be located
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationVariable Speed Convertible Air Handler 4 Ton
Submittal Variable Speed Convertible Air Handler 4 Ton TEM6A0D48H41S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These
More informationAHP SERIES INSTALLATION INSTRUCTIONS ELECTRIC FURNACES / AIR HANDLERS
AP SERIES INSTALLATION INSTRUTIONS ELETRI FURNAES / AIR ANDLERS A. Introduction These Air andlers come in a variety of models and sizes for upflow, or horizontal use and come from the factory with cooling
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More information157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device
More informationRuud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationRheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationFEM4X. Product Specifications FAN COILS /14/15
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator
More informationTPLP PRE-ASSEMBLED LOW PROFILE EVAPORATORS
PRODUT DATA & INSTALLATION PRE-ASSEMBLED LOW PROFILE S N O W F E A T U R I N G Air & Electric DEFROST ELETRIAL POWER: 115/1/60, 208-230/1/60, 208-230/3/60, 460/1/60 See Page 16 for details Bulletin T30--PDI-6
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More information49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3
More information49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)
ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More informationMERIT SERIES Up Flow / Horizontal
A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional
More informationTECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are
More informationIMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2
Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationTECHNICAL MANUAL MBVC
TEHNIAL MANUAL AL MBV Blowers efer to Service Manual S0000 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual. efer
More informationRooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type
More informationProduct Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More information