DESIGN & TECHNICAL MANUAL

Size: px
Start display at page:

Download "DESIGN & TECHNICAL MANUAL"

Transcription

1 AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_

2 Notices: Product specifications and design are subject to change without notice for future improvement. For further details, please check with our authorized dealer. Trademarks FGLair is trademark of Fujitsu General Limited in the United States, other countries or both. Google Play is trademark of Google Inc. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Copyright 2017 Fujitsu General Limited. All rights reserved.

3 CONTENTS Part 1. INDOOR UNIT Specifications Dimensions Models: ASYG07KGTA, ASYG09KGTA, ASYG12KGTA, and ASYG14KGTA Wiring diagrams Models: ASYG07KGTA, ASYG09KGTA, ASYG12KGTA, and ASYG14KGTA Capacity table Cooling capacity Heating capacity Fan performance Air velocity distributions Airflow Operation noise (sound pressure) Noise level curve Sound level check point Safety devices External input and output External input External output Combination of external input and output Details of function Group connection Remote controller Wireless remote controller Function settings Function settings by using remote controller Custom code setting for wireless remote controller Accessories Models: ASYG07KGTA, ASYG09KGTA, ASYG12KGTA, and ASYG14KGTA Optional parts Controllers Others... 42

4 CONTENTS (continued) Part 2. OUTDOOR UNIT Specifications Dimensions Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA Installation space Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA Refrigerant circuit Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA Wiring diagrams Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA Capacity compensation rate for pipe length and height difference Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA Additional charge calculation Models: AOYG07KGCA and AOYG09KGCA Models: AOYG12KGCA and AOYG14KGCA Airflow Model: AOYG07KGCA Model: AOYG09KGCA Model: AOYG12KGCA Model: AOYG14KGCA Operation noise (sound pressure) Noise level curve Sound level check point Electrical characteristics Safety devices Accessories Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA... 60

5 Part 1. INDOOR UNIT WALL MOUNTED TYPE: ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA

6 WALL MOUNTED 1. Specifications Type Wall mounted Inverter heat pump Model name ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA Power supply 230 V ~ 50 Hz Available voltage range V Capacity Cooling Rated kw Btu/h 6,800 8,500 11,600 14,300 Min. Max. kw Btu/h 3,100 10,900 3,100 11,600 3,100 14,000 3,100 15,400 Heating Rated kw Btu/h 8,500 9,500 13,600 18,400 Min. Max. kw Btu/h 3,100 17,700 3,100 18,400 3,100 20,800 3,100 21,800 Rated Cooling Min. Max kw Rated Heating Min. Max Input power HIGH Fan MED W LOW QUIET Current Cooling Rated A Heating EER Cooling kw/kw COP Heating Sensible capacity Cooling kw Power factor Cooling % Heating Moisture removal L/h (pints/h) 1.0 (1.76) 1.3 (2.288) 1.8 (3.168) 2.1 (3.696) Maximum operating current *1 Cooling A Heating HIGH Cooling MED LOW Fan QUIET Airflow rate m /h HIGH MED Heating LOW QUIET Type Q'ty Cross flow fan 1 Motor output W HIGH Cooling MED LOW Sound pressure level *2 QUIET db (A) HIGH Heating MED LOW QUIET Dimensions (H W D) Main1: Main1: Main2: mm Main2: Sub: Heat exchanger type Fin pitch Man1: 1.2, Main2: 1.1 Man1: 1.2, Main2: 1.1, Sub: 1.4 Rows Stages Main1: 2 10, Main2: 2 7 Main1: 2 10, Main2: 2 7, Sub: 1 4 Pipe type Copper tube Fin type Aluminum Material Polystyrene Enclosure White + Pearl white (painted) Color Approximate color of Munsell N 9.25/ Dimensions Net mm (H W D) Gross Weight Net 10.0 kg Gross Liquid Ø 6.35 (Ø 1/4) Size mm (in) Connection pipe Gas Ø 9.52 (Ø 3/8) Method Flare Drain hose Material PP+LLDPE Size mm Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.) C 18 to 32 Cooling Operation range %RH 80 or less Heating C 16 to 30 Remote controller type Wireless (Wired, Mobile app*3 [FGLair ] [option]) NOTES: Specifications are based on the following conditions: Cooling: Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating: Indoor temperature of 20 CDB/15 CWB, and outdoor temperature of 7 CDB/6 CWB. Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.) Protective function might work when using it outside the operation range. *1: Maximum current is maximum value when operated within the operation range. *2: Sound pressure level: Measured values in manufacturer s anechoic chamber. Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here. *3: Available on Google Play store or on App Store. Optional WLAN adapter is also required. For details, refer to the setting manual

7 Model name ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA Energy efficiency class Cooling A +++ A ++ Heating (Average) A +++ A + Pdesign Cooling 2.0 (35 C) 2.5 (35 C) 3.4 (35 C) 4.2 (35 C) kw Heating (Average) 2.3 (-10 C) 2.4 (-10 C) 2.5 (-10 C) 4.0 (-10 C) SEER Cooling kwh/kwh SCOP Heating (Average) Annual energy consumption QCE kwh/a QHE (Average) ,298 Sound power level Cooling HIGH db (A) Heating WALL MOUNTED - 3 -

8 2. Dimensions 2-1. Models: ASYG07KGTA, ASYG09KGTA, ASYG12KGTA, and ASYG14KGTA Unit: mm (834) Outline of indoor unit (270) 9.5 WALL MOUNTED for pipe inlet Ø65 for pipe inlet Ø65-4 -

9 Installation space requirement Provide sufficient installation space for product safety. Unit: mm WALL MOUNTED 50 or more 67 or more 40 or more 70 or more Wall hook bracket 107 or more Outline of the indoor unit 183 or more 1,500 or more 1,800 or more The flare connection part should be installed outdoors

10 WALL MOUNTED 3. Wiring diagrams 3-1. Models: ASYG07KGTA, ASYG09KGTA, ASYG12KGTA, and ASYG14KGTA - 6 -

11 4. Capacity table Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) WALL MOUNTED 4-1. Cooling capacity Model: ASYG07KGTA AFR m 3 /h 650 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP kw kw kw kw kw kw kw Model: ASYG09KGTA AFR m 3 /h 700 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP kw kw kw kw kw kw kw Model: ASYG12KGTA AFR m 3 /h 700 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP kw kw kw kw kw kw kw

12 WALL MOUNTED Model: ASYG14KGTA AFR m 3 /h 770 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP kw kw kw kw kw kw kw

13 4-2. Heating capacity NOTE: Values mentioned in the table are calculated based on the maximum capacity. Model: ASYG07KGTA WALL MOUNTED AFR m 3 /h 720 Outdoor temperature Indoor temperature CDB CWB TC IP TC IP TC IP TC IP TC IP kw kw kw kw kw Model: ASYG09KGTA AFR m 3 /h 750 Outdoor temperature Indoor temperature CDB CWB TC IP TC IP TC IP TC IP TC IP kw kw kw kw kw Model: ASYG12KGTA AFR m 3 /h 770 Outdoor temperature Indoor temperature CDB CWB TC IP TC IP TC IP TC IP TC IP kw kw kw kw kw Model: ASYG14KGTA AFR m 3 /h 800 Outdoor temperature Indoor temperature CDB CWB TC IP TC IP TC IP TC IP TC IP kw kw kw kw kw

14 WALL MOUNTED 5. Fan performance 5-1. Air velocity distributions Models: ASYG07KGTA and ASYG09KGTA Measuring conditions Fan speed HIGH Operation mode FAN (m) 3 Unit: m/s 2 1 Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center (m) (m) 3 Unit: m/s 2 Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left & Right (m) (m) 3 Unit: m/s 2.0 Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center (m) (m) 3 Unit: m/s Side view Vertical airflow direction louver: Down Horizontal airflow direction louver: Center (m)

15 Models: ASYG12KGTA and ASYG14KGTA Fan speed Measuring conditions HIGH (m) 3 Operation mode FAN Unit: m/s WALL MOUNTED 2 1 Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center (m) (m) 3 Unit: m/s 2 Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left & Right (m) (m) 3 Unit: m/s Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center (m) (m) 3 Unit: m/s Side view Vertical airflow direction louver: Down Horizontal airflow direction louver: Center (m)

16 WALL MOUNTED 5-2. Airflow Model: ASYG07KGTA Cooling Fan speed HIGH MED LOW QUIET Airflow m 3 /h 650 l/s 181 CFM 383 m 3 /h 540 l/s 150 CFM 318 m 3 /h 430 l/s 119 CFM 253 m 3 /h 270 l/s 75 CFM 159 Heating Fan speed HIGH MED LOW QUIET Airflow m 3 /h 720 l/s 200 CFM 424 m 3 /h 580 l/s 161 CFM 341 m 3 /h 460 l/s 128 CFM 271 m 3 /h 330 l/s 92 CFM

17 Model: ASYG09KGTA Cooling Fan speed HIGH MED LOW QUIET Airflow m 3 /h 700 l/s 194 CFM 412 m 3 /h 560 l/s 156 CFM 330 m 3 /h 430 l/s 119 CFM 253 m 3 /h 270 l/s 75 CFM 159 WALL MOUNTED Heating Fan speed HIGH MED LOW QUIET Airflow m 3 /h 750 l/s 208 CFM 441 m 3 /h 610 l/s 169 CFM 359 m 3 /h 470 l/s 131 CFM 277 m 3 /h 330 l/s 92 CFM

18 WALL MOUNTED Model: ASYG12KGTA Cooling Fan speed HIGH MED LOW QUIET Airflow m 3 /h 700 l/s 194 CFM 412 m 3 /h 560 l/s 156 CFM 330 m 3 /h 430 l/s 119 CFM 253 m 3 /h 250 l/s 69 CFM 147 Heating Fan speed HIGH MED LOW QUIET Airflow m 3 /h 770 l/s 214 CFM 453 m 3 /h 640 l/s 178 CFM 377 m 3 /h 520 l/s 144 CFM 306 m 3 /h 310 l/s 86 CFM

19 Model: ASYG14KGTA Cooling Fan speed HIGH MED LOW QUIET Airflow m 3 /h 770 l/s 214 CFM 453 m 3 /h 600 l/s 167 CFM 353 m 3 /h 450 l/s 125 CFM 265 m 3 /h 280 l/s 78 CFM 165 WALL MOUNTED Heating Fan speed HIGH MED LOW QUIET Airflow m 3 /h 800 l/s 222 CFM 471 m 3 /h 660 l/s 183 CFM 388 m 3 /h 520 l/s 144 CFM 306 m 3 /h 340 l/s 94 CFM

20 WALL MOUNTED 6. Operation noise (sound pressure) 6-1. Noise level curve Model: ASYG07KGTA Cooling 80 Heating 80 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz Model: ASYG09KGTA Cooling 80 Heating 80 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz

21 Model: ASYG12KGTA Cooling 80 Heating 80 WALL MOUNTED Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz Model: ASYG14KGTA Cooling 80 Heating 80 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave band sound pressure level, db: (0 db= µbar) QUIET HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz

22 WALL MOUNTED 6-2. Sound level check point 0.8 m Microphone Microphone 1 m NOTE: Detailed shape of the actual indoor unit might be slightly different from the one illustrated above

23 7. Safety devices Type of protection Protection form ASYG07KGTA Model ASYG09KGTA Circuit protection Current fuse (PCB*) 250 V, 3.15 A Fan motor protection Thermistor protection Activate More than 85 C Fan motor speed down Reset 85 C or less Fan motor speed recover WALL MOUNTED Type of protection Fan motor protection Protection form Power IC thermal shutdown protection ASYG12KGTA Model Circuit protection Current fuse (PCB*) 250 V, 3.15 A 125±25 C Activate Fan motor stop *PCB: Printed Circuit Board Reset C Fan motor restart ASYG14KGTA

24 WALL MOUNTED 8. External input and output External input and output PCB SW301 SW302 Rotary switch CN314 CN313 CN312 CN311 CN310 CN308 CN6 Indoor unit PCB PCB External input External output Connector Input select External input and output (UTY-XCSXZ2) Input signal Operation/Stop CN313/ Dry contact/ Edge/Pulse Forced stop - CN314 Apply voltage Forced thermostat off CN313 Edge Operation status CN310 Error status CN Indoor unit fan CN312 operation status

25 8-1. External input With using external input function, some functions on this product can be controlled from an external device. Operation/Stop mode or "Forced stop" mode can be selected with function setting of indoor unit. A twisted pair cable should be used. Maximum length of cable is 150 m. The wire connection should be separate from the power cable line. External input and output PCB The indoor unit Operation/Stop can be set by using the input connector on the PCB. Input select: Use either one of these types of connectors according to the application. (Both types of connectors cannot be used simultaneously.) Dry contact In case of internal power supply, set the slide switch of SW301 to "NON VOL" side. Connected unit PCB * Input Connector (CN313) WALL MOUNTED * Input Connector (CN314) *1: The switches can be used on the following condition: DC 12 V to 24 V, 1 ma to 15 ma. Apply voltage In case of external power supply, set the slide switch of SW301 to "VOL" side. Connected unit PCB * Input 1 - *2 + Power supply Connector (CN313) * Input Connector (CN314) *1: The switches can be used on the following condition: DC 12 V to 24 V, 1 ma to 15 ma. *2: Make the power supply DC 12 to 24 V, 10 ma or more

26 WALL MOUNTED 8-2. External output Use an external output cable with appropriate external dimension, depending on the number of cables to be installed. External input and output PCB A twisted pair cable (22AWG) should be used. Maximum length of cable is 25 m. Output voltage: High DC 12 V±2 V, Low 0 V. Permissible current: 50 ma For details, refer to "Combination of external input and output" on page 23. When indicator or other components are connected directly: Example: Function setting 60 is set to "00". Connected unit PCB LED 1 (Operation status) Resistor Connector (CN310) LED 2 (Error status) Resistor Connector (CN311) LED 3 (Indoor unit fan operation status) Resistor Connector (CN312) When connecting with a device equipped with a power supply: Example: Function setting 60 is set to "00". Connected unit Relay + Connected device 1 (Operation status) - PCB 1 2 Connector (CN310) + Connected device 2 (Error status) Connector (CN311) Connected device 3 + (Indoor unit fan operation status) Connector (CN312)

27 8-3. Combination of external input and output By combining the function setting of the indoor unit and rotary switch setting of the External input and output PCB, you can select various combinations of functions. Combination examples of external input and output are as follows: WALL MOUNTED Mode Function setting External input and output PCB (Rotary SW) to B C D Mode Function setting External input External input and output PCB CN313 CN314 Signal type Operation/Stop Not available Edge Operation Stop Pulse Forced Thermostat OFF Not available Edge 3-9, A (Setting prohibited) External input and output PCB (Rotary SW) Forced Thermostat OFF Forced Thermostat OFF Forced Thermostat OFF Not available Not available Not available External output External input and output PCB Edge Edge Edge CN310 CN311 CN Operation/Stop Error status Indoor unit fan operation status Error status Indoor unit fan operation status Not available to , A (Setting prohibited) B Operation/Stop Indoor unit fan operation status Not available C Operation/Stop Error status Not available D Operation/Stop Indoor unit fan operation status Error status NOTE: Input of Operation/Stop depends on the setting of function setting : Operation/Stop mode 1 (R.C. enabled) 01: (Setting prohibited) 02: Forced stop 03: Operation/Stop mode 2 (R.C. disabled)

28 WALL MOUNTED Input signal type External input and output PCB: The input signal type can be selected. Signal type (edge or pulse) can be switched by the DIP switch SW302 on the External input and output PCB. Edge The width of pulse must be longer than 200 msec. Pulse

29 8-4. Details of function Control input function When function setting is "Operation/Stop" mode 1 In the case of "Edge" input: WALL MOUNTED Function setting / Rotary SW on External input and output PCB / 1 External input Input signal Command External input and output PCB CN313 Off On On Off Operation Stop CN313 On Off Indoor unit Operation Stop Remote controller On In the case of "Pulse" input: Function setting / Rotary SW on External input and output PCB / 1 External input Input signal Command External input and output PCB CN313 Pulse Operation CN314 Pulse Stop CN313 On Off CN314 On Off Indoor unit Operation Stop Remote controller NOTES: The last command has priority. The indoor units within the same remote controller group operates in the same mode. On

30 WALL MOUNTED When function setting is "Forced stop" mode In the case of "Edge" input: Function setting / Rotary SW on External input and output PCB / 1 External input Input signal Command External input and output PCB CN313 Off On On Off Forced stop Normal CN313 On Off Forced stop Normal Indoor unit Operation Stop Remote controller On On On In the case of "Pulse" input: Function setting / Rotary SW on External input and output PCB / 1 External input Input signal Command External input and output PCB CN313 Pulse Forced stop CN314 Pulse Normal CN313 CN314 On Off On Off Forced stop Normal Indoorunit Operation Stop Remote controller On On On NOTES: When the forced stop is triggered, indoor unit stops and Operation/Stop operation by the remote controller is restricted. When forced stop function is used with forming a remote controller group, connect the same equipment to each indoor unit within the group

31 When function setting is "Operation/Stop" mode 2 In the case of "Edge" input: Function setting / Rotary SW on External input and output PCB / 1 External input Input signal Command External input and output PCB CN313 Off On On Off Operation Stop (R.C. disabled) WALL MOUNTED CN313 On Off Operation Indoor unit Stop (R.C. disabled) Remote contoller On Off On In the case of "Pulse" input: Function setting / Rotary SW on External input and output PCB / 1 External input Input signal Command External input and output PCB CN313 Pulse Operation CN314 Pulse Stop (R.C. disabled) CN313 On Off CN314 On Off Operation Indoor unit Stop (R.C. disabled) Remote controller On Off On NOTE: When "Operation/Stop" mode 2 function is used with forming a remote controller group, connect the same equipment to each indoor unit within the group

32 WALL MOUNTED Forced thermostat off function Function setting / Rotary SW on External input and output PCB / / B / C External input Input signal Command External input and output PCB CN313 Off On On Off Thermostat off Normal operation Input On Off Compressor On Off Room temp. Set temp

33 Control output function Operation/Stop status Function setting / Rotary SW on External input and output PCB / 1 External output External input and output PCB CN310 Output signal Off On On Off Command Operation Stop WALL MOUNTED The output is low when the unit is stopped. Operation Indoor unit Stop CN310 On Off Error status Function setting / Rotary SW on External input and output PCB / 1 External output External input and output PCB CN311 Output signal Off On On Off Command Error Normal The output is ON when an error is generated for the indoor unit. Error Indoor unit Normal CN On Off Indoor unit fan operation status Function setting / Rotary SW on External input and output PCB / 1 External output External input and output PCB CN312 Output signal Off On On Off Command Fan run Fan stop Output signal On Low High Off High Low Condition The indoor unit fan is operating. The fan is stopped or during cold air prevention. During thermostat off when in dry mode operation. Indoor unit Fan run Fan stop CN On Off

34 WALL MOUNTED 9. Group connection Installation procedure for group control system: A number of indoor units can be operated at the same time using a single remote controller. NOTE: When different type of indoor units (such as wall mounted type and cassette type, cassette type and duct type, or other combinations) are connected using group control system, some functions may no longer be available. 1. Connect up to 16 indoor units in a system. I.U. I.U. I.U. I.U. A B C D E Remote controller A, B, C, D, E: Remote controller cable A + B + C + D + E 500 m Example of wiring method Indoor unit 1 Indoor unit 2 Indoor unit 3 Indoor unit R W Remote controller Remote controller cable Bus wire 2. Set the R.C. address. (Function setting) Addresses will be automatically set when initially starting up this unit. In such a case, do not change the remote controller address for the indoor unit, and keep it at the initial setting of 00. Only set addresses manually when using different numbers for addresses. Set the R.C. address of each indoor unit using the function setting. (Refer to Remote controller address setting in "Contents of function setting" on page 35.) NOTES: Do not use the same setting value. Setting is reflected after the power is turned on again. Also set the R.C. address for the remote controller. For details, refer to the remote controller installation manual. NOTE: In manual setting, connect up to 15 indoor units in a system. Example of wiring method Indoor unit 1 Indoor unit 2 Indoor unit 3 Indoor unit 4 RC AD 01 RC AD 02 RC AD 03 RC AD 04 Remote controller

35 10. Remote controller Wireless remote controller Overview WALL MOUNTED Signal transmitter SENSOR button 10 C HEAT button MODE button FAN button TEMP. button POWERFUL button Start/Stop button ECONOMY button OUTDOOR UNIT LOW NOISE button TIMER SETTING button SEND button SWING button SET button WEEKLY button ON/OFF button SELECT button RESET button SLEEP button NEXT button BACK button TEST RUN button CLOCK ADJUST button NOTE: Display panel Functions may differ by type of the indoor unit. For details, refer to the operation manual. Transmit indicator Temperature indicator Mode indicator ENERGY SAVING mode indicator Turns on when the SENSOR button is operated. LOW NOISE mode indicator SEND indicator Fan speed indicator Swing indicator Clock and Timer indicator To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual operation, however, the display will only show those indicators appropriate to the current operation

36 WALL MOUNTED Specifications Controller Unit: mm Top view Front view 17 Side view Size (H W D) mm Weight g 122 (without batteries) Holder Unit: mm Ø 3.5 (Hole) R Hole Front View Side View Bottom View Size (H W D) mm Weight g

37 11. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. WALL MOUNTED Function settings by using remote controller Some function settings can be changed on the remote controller. After confirming the setting procedure and the content of each function setting, select appropriate functions for your installation environment. NOTE: Incorrect settings can cause a product malfunction. Setting procedure by using wireless remote controller The function number and the associated setting value are displayed on the LCD of the remote controller. Follow the instructions written in the local setup procedure supplied with the remote controller, and select appropriate setting according to the installation environment. Before connecting the power supply of the indoor unit, reconfirm following items: Cover for the electrical enclosure on the outdoor unit is in place. There is no wiring mistake. Piping air tight test and vacuuming have been performed firmly. All the necessary wiring work for outdoor unit has been finished. After reconfirming the items listed above, connect the power supply of the indoor unit. NOTES: Settings will not be changed if invalid numbers or setting values are selected. When optional wired remote controller is used, refer to the installation manual enclosed with the remote controller. Entering function setting mode: While pressing the POWERFUL button and TEMP. ( ) button simultaneously, press the RESET button to enter the function setting mode. Function number Setting value Selecting the function number and setting value: 1. Press the TEMP. ( ) ( ) buttons to select the function number. To switch between the left and right digits, press the 10 C HEAT button. 2. Press the POWERFUL button to proceed to value setting. To return the function number selection, press the POWERFUL button again. 3. Press the TEMP. ( ) ( ) buttons to select the setting value. To switch between the left and right digits, press the 10 C HEAT button. 4. Press the MODE button once to send the function setting information. Confirm that you hear the beep sound. 5. Press the START/STOP button to fix the function setting. Confirm that you hear the beep sound. 6. Press the RESET button to end the function setting mode. 7. After completing the function setting, be sure to disconnect the power supply and then reconnect it

38 WALL MOUNTED CAUTION After disconnecting the power supply, wait 30 seconds or more before reconnecting it. The function setting will not become active unless the power supply is disconnected and then reconnected. NOTES: The air conditioner custom code is set to prior to shipment. If you do not know the air conditioner custom code setting, try each of the custom codes ( ) until you find the code that operates the air conditioner

39 Contents of function setting Each function setting listed in this section is adjustable in accordance with the installation environment. NOTE: Setting will not be changed if invalid numbers or setting values are selected. WALL MOUNTED Function setting list Function no. Functions 1) 00 Remote controller address setting 2) 11 Filter sign 3) 30/31 Room temperature control for indoor unit sensor 4) 35/36 Room temperature control for wired remote controller sensor 5) 40 Auto restart 6) 42 Room temperature sensor switching 7) 44 Remote controller custom code 8) 46 External input control 9) 48 Room temperature sensor switching (Aux.) 10) 49 Indoor unit fan control for energy saving for cooling 11) 60 Switching functions for external output terminal 1) Remote controller address setting NOTE: Because this setting is normally done automatically when 2-wire-type wired remote controller is installed, setting is unnecessary. Multiple indoor units can be operated by using one wired remote controller. Set the unit number of each indoor unit. Function number Setting value Setting description Factory setting Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no Unit no. 15 NOTE: When different type of indoor units (such as wall mounted type and cassette type, cassette type and duct type, or other combinations) are connected using group control system, some functions may no longer be available

40 WALL MOUNTED 2) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room. If the indication is not required, select "No indication" (03). Function number Setting value Setting description Factory setting Standard (400 hours) 01 Long interval (1,000 hours) 02 Short interval (200 hours) 03 No indication 3) Room temperature control for indoor unit sensor Depending on the installed environment, correction of the room temperature sensor may be required. Select the appropriate control setting according to the installed environment. The temperature correction values show the difference from the Standard setting "00" (manufacturer s recommended value). Function number Setting value Setting description 30 (For cooling) 31 (For heating) Factory setting 00 Standard setting 01 No correction 0.0 C C C C C C C C C C C C C C C C C More cooling Less heating Less cooling More heating

41 4) Room temperature control for wired remote controller sensor Depending on the installed environment, correction of the wire remote temperature sensor may be required. Select the appropriate control setting according to the installed environment. To change this setting, set Function 42 to Both 01. Ensure that the Thermo Sensor icon is displayed on the remote controller screen. WALL MOUNTED Function number Setting value Setting description 35 (For cooling) 36 (For heating) Factory setting 00 No correction 01 No correction 0.0 C C C C C C C C C C C C C C C C C More cooling Less heating Less cooling More heating 5) Auto restart Enables or disables automatic restart after a power interruption. Function number Setting value Setting description Factory setting Enable 01 Disable NOTE: Auto restart is an emergency function such as for power outage etc. Do not attempt to use this function in normal operation. Be sure to operate the unit by remote controller or external device. 6) Room temperature sensor switching (Only for wired remote controller) When using the wired remote controller temperature sensor, change the setting to "Both" (01). Function number Setting value Setting description Factory setting Indoor unit 01 Both 00: Sensor on the indoor unit is active. 01: Sensors on both indoor unit and wired remote controller are active. NOTE: Remote controller sensor must be turned on by using the remote controller

42 WALL MOUNTED 7) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. Select the appropriate custom code. Function number Setting value Setting description Factory setting A 01 B 02 C 03 D 8) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. Function number Setting value Setting description Factory setting Operation/Stop mode 1 01 (Setting prohibited) 02 Forced stop mode 03 Operation/Stop mode 2 9) Room temperature sensor switching (Aux.) To use the temperature sensor on the wired remote controller only, change the setting to "Wired remote controller" (01). This function will only work if the function setting 42 is set at "Both" (01). When the setting value is set to "Both" (00), more suitable control of the room temperature is possible by setting function setting 30 and 31 too. Function number Setting value Setting description Factory setting Both 01 Wired remote controller 10) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. Function number Setting value Setting description Factory setting Disable 01 Enable 02 Remote controller 00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting on the remote controller. 01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed. 02: Enable or disable this function by remote controller setting. NOTES: As the factory setting, this setting is initially activated. Set to "00" or "01" when connecting a remote controller that cannot set the Fan control for energy saving function or connecting a network converter. To confirm if the remote controller has this setting, refer to the operating manual of each remote controller

43 11) Switching functions for external output terminal Functions of the external output terminal can be switched. For details, refer to External input and output. Function number Setting value Setting description Factory setting Operation status 09 Error status 10 Indoor unit fan operation status WALL MOUNTED

44 WALL MOUNTED Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a custom code if the air conditioner has not been set for the custom code. Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code. When 2 or more air conditioners are installed in a room, and the remote controller is operating an air conditioner other than the one you wish to set, change the custom code of the remote controller to operate only the air conditioner you wish to set. (4 selections possible.) Confirm the setting of the remote controller custom code and the function setting. If these do not match, the remote controller cannot be used to operate for the air conditioner. 1. Press the START/STOP button until only the clock is displayed on the remote controller display. 2. Press the MODE button for at least 5 seconds to display the current custom code. (Initially set to.) 3. Press the TEMP. ( ) ( ) buttons to change the custom code between. Match the code on the display to the air conditioner custom code. (Initially set to.) 4. Press the MODE button again to return to the clock display. The custom code will be changed. NOTES: If no button is pressed within 30 seconds after the custom code is displayed, the system returns to the original clock indicator. In this case, start again from step 1. The air conditioner custom code is set to contact your retailer. prior to shipment. To change the custom code, If you do not know the assigned code for the air conditioner, try each of the custom code ( ) until you find the code which operates the air conditioner

45 12. Accessories Models: ASYG07KGTA, ASYG09KGTA, ASYG12KGTA, and ASYG14KGTA WALL MOUNTED Part name Exterior Q ty Part name Exterior Q ty Operating manual 1 Cloth tape 1 Installation manual 1 Tapping screw (Large) 5 Operating manual (CD ROM) 1 Tapping screw (Small) 2 Remote controller 1 Wall hook bracket 1 Battery 2 Remote controller holder

46 WALL MOUNTED 13. Optional parts Controllers Exterior Part name Model name Summary Wired remote controller Wired remote controller UTY-RNRYZ* UTY-RLRY Easy finger touch operation with LCD panel. Backlit LCD enables easy operation in a dark room. Wire type: Non-polar 2-wire Optional communication kit is necessary for installation. High visibility and easy operation. Room temperature can be accurately controlled using the built-in thermo sensor. Wire type: Non-polar 2-wire Optional communication kit is necessary for installation. NOTE: Available functions may differ by the remote controller. For details, refer to the operation manual Others Exterior Part name Model name Summary External input and output PCB UTY-XCSXZ2 Use to connect with external devices and air conditioner PCB. Communication kit UTY-TWRXZ2 Use to connect Non-polar 2-core wired remote controller. Wireless LAN adapter UTY-TFSXW1 Remotely manage an air conditioning system using mobile devices such as smartphones and tablets

47 Part 2. OUTDOOR UNIT SINGLE TYPE: AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA

48 1. Specifications OUTDOOR UNIT AOYG07-14KGCA Type Inverter heat pump Model name AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA Power supply 230 V ~ 50 Hz Available voltage range V Starting current A Cooling Airflow rate m 3 1,610 1,610 1,680 1,680 /h Heating 1,560 1,610 1,580 1,580 Fan Type Q'ty Propeller fan 1 Motor output W 21 Sound pressure level *1 Cooling db (A) Heating Sound power level Cooling db (A) Heating Dimensions (H W D) mm Fin pitch 1.3 Heat exchanger type Rows Stages Pipe type Copper Fin type Type (Material) Corrugate (Aluminum) Surface treatment Corrosion resistance Compressor Type Q'ty Rotary 1 Motor output W 900 Refrigerant Type (Global warming potential) R32 (675) Charge g Refrigerant oil Type RB68A Amount cm Material Steel sheet Enclosure Beige Color Approximate color of Munsell 10YR 7.5/1.0 Dimensions Net mm (H W D) Gross Weight Net kg Gross Size Liquid Ø 6.35 (Ø 1/4) mm (in) Gas Ø 9.52 (Ø 3/8) Connection pipe Method Flare Pre-charge length 15 Max. length m 20 Max. height difference 15 Operation range Cooling -10 to 46 C Heating -15 to 24 Drain hose Material PP+LLDPE Size mm Ø 13.0 (I. D.), Ø 16.0 to Ø 16.8 (O. D.) NOTES: Specifications are based on the following conditions: Cooling: Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating: Indoor temperature of 20 CDB/15 CWB, and outdoor temperature of 7 CDB/6 CWB. Pipe length: 5 m, Height difference: 0 m. Protective function might work when using it outside the operation range. *1: Sound pressure level Measured values in manufacturer s anechoic chamber. Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here

49 2. Dimensions 2-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA 330 Pitch of bolts for installation Unit: mm OUTDOOR UNIT AOYG07-14KGCA 4-M10 hole Pitch of bolts for installation Top view Airflow Side view Front view Side view Drain port Ø Bottom view Side view (Bulb part)

50 3. Installation space 3-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA OUTDOOR UNIT AOYG07-14KGCA Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance. Single outdoor unit installation When the upper space is open: Unit: mm Obstacles at rear only Obstacles at rear and sides 100 or more 100 or more 250 or more 100 or more Obstacles at front Obstacles at front and rear 600 or more 600 or more 100 or more When there is an obstruction in the upper space: Unit: mm Obstacles at rear and above Obstacles at rear, sides, and above Max. 200 Max or more 600 or more 100 or more 100 or more 250 or more 100 or more

51 Multiple outdoor unit installation Provide at least 250 mm of space between the outdoor units if multiple units are installed. When routing the piping from the side of an outdoor unit, provide space for piping. No more than 3 units must be installed side by side. When 3 units or more are arranged in a line, provide the space as shown in the following example When an obstruction in the upper space:. When the upper space is open: Obstacles at rear only Obstacles at front only Unit: mm OUTDOOR UNIT AOYG07-14KGCA 250 or more 250 or more 200 or more 1,000 or more Obstacles at front and rear 250 or more 200 or more 1,000 or more When an obstruction in the upper space: Obstacles at rear and above. Unit: mm Max or more 1,500 or more 1,500 or more 250 or more 200 or more

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR G24LMLA OUTDOOR AO G24LALA 1. INDOOR UNIT : DTR_AR063E_01 2013.02.28 - (3) - 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

6. DUCT TYPE AR 60FUAK, AR 60UUAK

6. DUCT TYPE AR 60FUAK, AR 60UUAK R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AR C72LHTA AR C90LHTA OUTDOOR AO A72LALT AO A90LALT 1. INDOOR UNIT : AR C72LHTA AR C90LHTA DTR_AR061E_03 2013.11.08 1. INDOOR UNIT CONTENTS

More information

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC TECHNICAL CATALOGUE MONO SPLIT RAK-18PSC RAK-25PSC RAK-35PSC RAC-18WSC RAC-25WSC RAC-35WSC HITACHI Specifications in this catalogue are subject to change without prior notice in order for HITACHI to bring

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch

More information

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER DTV_OAE034E_03--CHAPTER01 2015.01.16 CONTENTS 1. FEATURES... A-01 2. SPECIFICATIONS... A-02 3. ELECTRIC CHARACTERISTICS... A-03 4. DIMENSIONS... A-05 5. REFRIGERANT CIRCUIT...A-11 6. WIRING... A-12 6-1.

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

Air Conditioners. Technical Data RZQG-L

Air Conditioners. Technical Data RZQG-L Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

Small VRF system. for light commercial and home use SERVICE MANUAL

Small VRF system. for light commercial and home use SERVICE MANUAL Small VRF system for light commercial and home use SERVICE MANUAL CONTENTS 1. TEST RUN 1-1 EXECUTION PROCEDURE AND EXECUTION PRECAUTIONS... 01-01 1-2 TEST RUN METHOD... 01-03 1-2-1 Check Items Before

More information

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT)

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT) Manual No. '4 KX-SM-202 SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS (OUTDOOR UNIT) KXZ series (Heat pump type) Standard series Single use (Used also for combination) FDC280KXZE, 335KXZE,

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG

TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAK-25PED/25PEDC RAK-35PED/35PEDC RAK-50PED/50PEDC RAS- X10/14/18EAG RAS-L10/14EAG RAS-M25/35/50EAG RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG

More information

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU9RLS ASURLS ASU5RLS AOU9RLSH AOURLSH AOU5RLSH R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G4LFCA AS*G4LFCC AS*G0LFCA AO*G4LFL AO*G4LFCC AO*G0LFT R40A CONTENTS. DESCRIPTION OF EACH

More information

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

Compact 4-way Cassette ( ) Type

Compact 4-way Cassette ( ) Type E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference

More information

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C Service Manual Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

SERVICE MANUAL INDOOR UNIT. No. OBH788

SERVICE MANUAL INDOOR UNIT. No. OBH788 INDOOR UNIT SERVICE MANUAL. Models MSZ-AP25VG - E1, EN1 MSZ-AP35VG - E1, EN1 MSZ-AP42VG - E1, EN1 MSZ-AP50VG - E1, EN1 MSZ-AP25VGK - E1, EN1 MSZ-AP35VGK - E1, EN1 MSZ-AP42VGK - E1, EN1 MSZ-AP50VGK - E1,

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models CEILING CASSETTE TYPE, HEAT PUMP AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH483 Ceiling cassette type Models E1 MLZ-KA25VA - E1 MLZ-KA35VA - MLZ-KA50VA - E1 Outdoor unit service manual MXZ-A VA Series

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-FH25VE2 MSZ-FH35VE2 MSZ-FH50VE2 INDOOR UNIT. No. OBH623. Models

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-FH25VE2 MSZ-FH35VE2 MSZ-FH50VE2 INDOOR UNIT. No. OBH623. Models Revision D: MSZ-FH25VE2- E1, ER1, MSZ- FH35VE2- E1, ER1 and MSZ- FH50VE2- E1, ER1 have been added. Please void OBH623 REVISED EDITION-C. INDOOR UNIT SERVICE MANUAL. OBH623 REVISED EDITION-D Models MSZ-FH25VE

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No. SPLIT-TYPE AIR CONDITIONERS Revision E: Detail of the indoor fan speed control in COOL or DRY operation has been added (9-1.3, 9-2.3). Please void OBH515 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL.

More information

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379224 07H050_cover.p65 2007.8.7, 0:27 AM CONTENTS SAFETY PRECAUTIONS... FEATURES

More information

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type

More information

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type H-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type H-Series Cooling Only Indoor Unit FTXS30HVJU

More information

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information