1 Wireless Controls System Guide As of September 6, 2018

2 Table of Contents 1.0 Introduction Why SALUS? Using this Manual System Overview SALUS Wireless System Components with Internet Connection SALUS Wireless System Components without Internet Connection Device Installation SG888ZB Gateway Installation AC10RF Coordinator Installation AS20WRF/BRF Digital Thermostat Installation AS20WRF/BRF Digital Thermostat Starting Sequence AKL01PRF Zone Pump Wiring Center Installation AKL04/06PRF Zone Pump Wiring Center Installation AKL08RF Zone Valve Wiring Center Installation AX10RF Receiver Installation ARV10RFM Radiator Valve Actuator Installation Device Pairing & Setup with Internet Connection System Configuration with Internet Connection using SG888ZB Gateway AS20WRF/BRF Thermostat Configuration AS20WRF/BRF Thermostat with AKL01/04/06PRF and AKL08RF Wiring Centers AS20WRF/BRF Thermostat with ARV10RFM Radiator Valve Actuator AS20WRF/BRF Thermostat with AX10RF Receiver for Boiler Switching (RX1) AS20WRF/BRF Thermostat with AX10RF Receiver for Zone Valve Operation (RX2) Device Pairing & Setup without Internet System Configuration without Internet Connection using AC10RF Coordinator AS20WRF/BRF Thermostat Configuration AS20WRF/BRF Thermostat withakl01/04/06prf or AKL08RF Wiring Center AS20WRF/BRF Thermostat with ARV10RFM Radiator Valve Actuator AS20WRF/BRF Thermostat with AX10RF Receiver for Boiler Switching (RX1) AS20WRF/BRF Thermostat with AX10RF Receiver for Zone Valve Operation (RX2)

3 Table of Contents 6.0 Resetting Factory Defaults Resetting the SG888ZB Gateway with Internet Connection Resetting the SG888ZB Gateway without Internet Connection Resetting the AC10RF Coordinator without Internet Connection Resetting the AS20WRF/BRF Thermostat without Internet Connection Resetting the AKL01/04/06PRF Zone Pump or AKL08RF Zone Valve Wiring Center Resetting the AX10RF Receiver Resetting the ARV10RFM Radiator Valve Actuator Setting Device Parameters AS20WRF/BRF Thermostat User Interface Key AS20WRF/BRF Thermostat Installer Parameter Setup AS20WRF/BRF Thermostat Functions & Parameters AS20WRF/BRF Thermostat Setting the Time AS20WRF/BRF Thermostat Setting the Temperature AS20WRF/BRF Thermostat Schedule Set Up AS20WRF/BRF Thermostat Temporary Override AS20WRF/BRF Thermostat Permanent Temperature Hold AS20WRF/BRF Thermostat Parameter Setup with Internet Connection AS20WRF/BRF Thermostat SALUS Smart Home Application Functions & Parameters AS20WRF/BRF Thermostat Parameter Access Instructions with Internet Connection AS20WRF/BRF Thermostat SALUS Smart Home Application Advanced Functions & Parameters AS20WRF/BRF Thermostat Schedule Setup with Internet Connection Troubleshooting AS20WRF/BRF Thermostat Error Codes and Corrective Actions A Appendix A

4

5 Section 1 Introduction Why SALUS? SALUS designs and manufactures industry-leading hydronics, HVAC and fan coil products for heating engineers and contractors who need to deliver customer satisfaction while driving profitability. We enable contractors to provide homeowners and building managers with the comfort and control they need while reducing installation times and minimizing costly call-backs. Our proven, innovative products, such as easy-to-install wireless hydronic controls, and patented, industry first auto-balancing actuators are advancing the industry. SALUS also offers a broad ecosystem of smart home products, including connected thermostats, a smart home hub, smart plugs, water valve shutoff, and door and window sensors. A proven leader in the European market since 2003, SALUS is currently expanding across North America. Using this Manual For the latest instructions go to: Special Attention Boxes This manual uses special attention icons to alert the reader of important safety concerns, information important to reliable operation of the controls or helpful installation/setup information Safety: Indicates a condition which may cause severe personal injury, death or major property damage Important Information: Indicates information which requires special attention for correct operation of the control Your Benefit: Indicates helpful installation or setup information 1.1

6 Section 2 System Overview The SALUS Wireless System uses the Zigbee 3.0 communications protocol to provide a universal language for smart components to work together seamlessly and securely, with or without an internet connection. SALUS Wireless System Components with Internet Connection AX10RF- Receiver Configured for a Boiler (RX1) AX10RF- Receiver Configured for a Zone Valve (RX2) AKL01PRF-1 Zone Pump Wiring Center AKL04PRF-4 Zone Pump Wiring Center AS20WRF-Digital Thermostat SS882ZB- Door/Window Sensor SG8888ZB-Gateway AKL06PRF-6 Zone Pump Wiring Center ARV10RFM- Radiator Valve Actuator Back HeatLink SS881ZB-Embedded Door Sensor Welcome to HeatLink! As a first time user please complete a few simple steps to manage your account and equipment. Let s get started setting up your new system. Create your profile First Name Last Name Address Confirm Address SX883ZB minismartplug AKL08RF-Zone Valve Wiring Center By connecting the SG888ZB Gateway to your system router, the system is connected to the internet. Monitor or adjust your system from anywhere via the SALUS Smart Home remote app for ios or Android. If the connection to the internet is lost, the system continues to function with the settings selected. 2.1

7 Section 2 System Overview Download the SALUS Smart Home app on your ios or Android device to for remote access to your SALUS controls. Apple, the Apple logo, iphone, and ipod touch are trademarks of Apple Inc, registered in the U.S. and other countries. App Store is a service mark of Apple Inc, registered in the U.S. and other countries Google Play and the Google Play logo are trademarks of Google LLC. For security purposes, you will be prompted to set up a user profile including username & password. Use SALUS Smart Home to: Quickly view and monitor the status of your home and smart devices Set schedules and preferences for your connected thermostats, smart plugs and more Receive important real-time alerts and notifications of any changes that occur with your system Back HeatLink Back HeatLink Back HeatLink Welcome to HeatLink! As a first time user please complete a few simple steps to manage your account and equipment. Let s get started setting up your new system. Create your profile Welcome to HeatLink! As a first time user please complete a few simple steps to manage your account and equipment. Let s get started setting up your new system. Create your profile Welcome to HeatLink! As a first time user please complete a few simple steps to manage your account and equipment. Let s get started setting up your new system. Create your profile First Name First Name First Name Last Name Last Name Last Name Address Address Address Confirm Address Confirm Address Confirm Address 2.2

8 Section 2 System Overview The AC10RF Coordinator uses Zigbee communication protocol to connect all system components, providing wireless communication easily and securely without connecting to the internet. SALUS Wireless System Components without Internet Connection AX10RF- Receiver Configured for a Zone Valve (RX2) AKL01PRF-1 Zone Pump Wiring Center AKL04PRF-4 Zone Pump Wiring Center AX10RF- Receiver Configured for a Boiler (RX1) AC10RF- Coordinator AKL06PRF-6 Zone Pump Wiring Center AS20WRF-Digital Thermostat ARV10RFM-3 Radiator Valve Actuator AKL08RF-Zone Valve Wiring Center 2.3

9 Section 3 Device Installation SALUS components must be set up for wireless communication with the SG888ZB Gateway or with the AC10RF Coordinator. This process, called pairing, should be performed with all devices installed in their intended location. If the intended operating location is unsuitable for the pairing process due to convenience or other factors, the device may be moved to a convenient location during pairing. Once the device is paired and installed in its intended location, check the operation to make sure there are no issues with RF interference that will prevent it from operating correctly. SG888ZB Gateway Installation Install the SG888ZB Gateway in a central location close to a 120 VAC electrical receptical and free from radio frequency interference. If you intend to connect the system to the internet, the gateway should be close to your internet router. 1. Confirm that all required parts are present in the Gateway package: Gateway with port cover, Ethernet Cable, USB Power Cable, USB Power Adapter and Installation/Quick Start Guide 2. Remove the port cover from the bottom of the Gateway by twisting it ¼ turn counterclockwise LOCK UNLOCK 3. If connecting the SG888ZB Gateway to the internet, attach the ethernet cable and the power cable to the gateway only, making sure it is within reach of a router or ethernet connection a. For best results, DO NOT CONNECT the power cable to electrical power outlet until after ethernet cable is attached to the Router b. If no internet connection is intended, it is not necessary to attach the ethernet cable to the Gateway 4. Reattach the port cover on the Gateway 5. Connect the ethernet cable to the Router if desired 6. Plug the USB Power Cable into the USB Adapter and connect it to a 120 VAC outlet 3.1

10 Section 3 Device Installation Multi button Plug into 120V outlet LED light ring Wireless Internet gateway USB power adapter USB to micro USB cable Ethernet cable To Internet router (supplied by network provider) 7. When the SG888ZB Gateway powers up, the lighted ring around the multi button will be solid green. The light will then turn red. Once an internet connection is detected (if plugged into a router) the light will turn green. Using the internet connection, the SG888ZB Gateway will try to connect with the SALUS Smart Home services. If successful, the light will turn blue. Connected to SALUS Smart Home services. Not Connected to the Internet LED Indications Solid Blue Solid Red Flashing Red Gateway is connected to the internet and communicating with SALUS Smart Home services Gateway is not connected to the internet Gateway is waiting for device pairing Solid Green Flashing Green Gateway is powering up and attempting to establish connections Gateway is in identify mode 3.2

11 Section 3 Device Installation AC10RF Coordinator Installation Install the AC10RF Coordinator in a centrally located 120 VAC electrical receptacle. Alternatively, if using this device with an AKL08RF Zone Valve Wiring Center, there is a USB port in the chassis of the Wiring Center. 1. Connect the AC10RF Coordinator to the 120 VAC adapter. 2. Insert the adapter into a 120 VAC electrical receptacle and ensure that the LED ring at the button is illuminated. Prior to using the AC10RF Coordinator with an AKL01/04/06PRF Wiring Center, update the firmware version as follows: 1.Use a computer with an internet connection that meets the following requirements: COMPUTER PC Mac OPERATING SYSTEM Windows 8 or later OSX or later USB PORT Type A Type A 2. Connect to the SALUS Update Tool ( 3.Download and run the Update Tool by following the onscreen prompts 4. Insert the AC10RF Coordinator into a USB port on the computer when prompted to do so AS20WRF/BRF Digital Thermostat Installation SALUS components must be set up for wireless communication with the SG888ZB Gateway or with the AC10RF Coordinator. This process, called pairing, should be performed with all devices installed in their intended location. If the intended operating location is unsuitable for the pairing process for convenience or other factors, the device may be located in a convenient location during pairing. DO NOT Mount the AS20 Thermostat near any heat source, behind curtains, in direct sunlight, in areas of high humidity or area where water is present. 3.3

12 Section 3 Device Installation AVOID Mounting the AS20 Thermostat on an exterior wall. 1. Ensure that all required parts were included in the thermostat package: Thermostat with backplate, (4) AAA Batteries, (2) Mounting Screws, (2) Wall Anchors, Installation Instructions 2. Remove the AS20 Thermostat from the backplate by pulling out from the bottom Floor sensor 3. Connect an external 10 kω sensor (AFTS30M sold separately) if applicable Terminals are provided for a remote air sensor or floor sensor 4. Secure the backplate to the wall using the provided screws and wall anchors FOR BEST RESULTS, ensure that the backplate is level when mounting it. NOTE THE ORIENTATION ARROW molded into the backplate. This must be pointed upwards for correct mounting of the thermostat in (5.9944cm) 5. Insert batteries into the thermostat assuring correct polarity 6. Attach the thermostat onto the backplate by hooking the top connections and pressing firmly on the bottom. If the thermostat does not fully attach, make sure that the screws provided were used to attach the backplate and that they are snug. 3.4

13 Section 3 Device Installation AS20WRF/BRF Digital Thermostat Starting Sequence When the batteries are first installed in the AS20 Thermostat, the following starting sequence will occur. M12 A 1 ON OFF B PM Boot screen Display check The MCU software version (example only) The Zigbee software version (example only) The Thermostat is ready to be paired The starting sequence must be complete before pairing the AS20 Thermostat with the SG888ZB Gateway or AC10RF Coordinator, and other devices. 3.5

14 Section 3 Device Installation AKL01PRF Zone Pump Wiring Center Installation The AKL01PRF 1-Zone Pump Wiring Center pairs with an AS20 Wireless Thermostat via the SG888ZB Gateway or AC10RF Coordinator to provide a heat demand signal to the boiler and control a zone pump. The AKL01PRF Single Zone Pump Wiring Center must be installed by a qualified contractor. Installation and repairs are to be performed according to all national and local codes required by the authority having jurisdiction. In the absence of local requirements, follow ANSI/NFPA 70, National Electrical Code. Failure to follow these requirements may lead to severe personal injury, death or major property damage. DO NOT SERVICE this equipment without disconnecting the AC electrical power. 1. Carefully read these instructions and all instructions supplied with the unit before starting the installation. 2. Inspect the control for damage and be sure all required parts are included before beginning. 3. Remove 4 screws at the corners and lift off the plastic cover. 4. Check that the fuse installed is a 5A, slow blow fuse and that it is inserted correctly. 5. Attach the base of the AKL01PRF Zone Pump Wiring Center to a wall or similar vertical structure in a suitable location near the boiler and pumps using the hardware supplied. DO NOT INSTALL this control in an area where water leaks or spray are possible. Failure to comply may result in serious injury, death or major property damage due to electrocution or fire. Electrical Connections Dry Contacts (rated 120VAC, max.2a) XX Active Pump 120VAC Connections AC Line In L Zone Pump Line Out (max. 1/6 HP) N AC Neutral Earth Ground Fuse: 5A slow blow, 5x15mm (2AG) 6. BE SURE all electrical power to the device is disconnected before wiring the device. 7. Wire 120 VAC power to the L (Hot), N (Neutral) and (Ground) terminals labeled, POWER IN. 8. Wire the 120 VAC power output to the pump from L (Hot), N (Neutral) terminals labeled, PUMP. Connect the ground terminal to the POWER IN (Ground) terminal as shown in the wiring schematic. 9. Wire the output terminals labeled XX to the boiler thermostat input ( TT ). 10. Wire the thermostat contacts to R & W on the terminals labeled 24 VAC T-STAT. If a C wire is required connect it according to the drawing. 11. Reattach the control cover securing it with the 4 screws and switch on 120 VAC power to the unit. The LED labeled POWER will be illuminated. 3.6

15 Section 3 Device Installation AKL04/06PRF Zone Pump Wiring Center Installation The AKL04/06PRF Zone Pump Wiring Center pairs with an AS20WRF/BRF Wireless Thermostat via the SG888ZB Gateway or AC10RF Coordinator to provide a heat demand signal to the boiler and control a zone pump. They can control up to 6 pumps with outputs for multiple heat demands. The AKL04/06PRF Zone Pump Wiring Center must be installed by a qualified contractor. Installation and repairs are to be performed according to all national and local codes required by the authority having jurisdiction. In the absence of local requirements, follow ANSI/NFPA 70, National Electrical Code. Failure to follow these requirements may lead to severe personal injury,death or major property damage. DO NOT SERVICE this equipment without disconnecting the AC electrical power. 1. Carefully read these instructions and all instructions supplied with the unit before starting the installation. 2. Inspect the control for damage and be sure all required parts are included before beginning. 3. Remove 4 screws at the corners and lift off the plastic cover. 4. Check that the fuse installed is a 5A, slow blow fuse and that it is inserted correctly. 5. Attach the base of the AKL04PRF or AKL06PRF Zone Pump Wiring Center to a wall in a suitable location near the boiler and pumps using the hardware supplied. DO NOT INSTALL this control in an area where water leaks or spray are possible. Failure to comply may result in serious injury, death or major property damage due to electrocution or fire. 6. BE SURE all electrical power to the device is disconnected before wiring the device. 7. Wire 120 VAC power to the L (Hot), N (Neutral) and (Ground) terminals labeled, POWER IN. For correct operation, it is important that the priority dip switch position matches the wiring configuration: - See Appendix A for schematic diagrams for typical installations - If priority is OFF, the Zone 1 Thermostat cannot be wired, only a wireless thermostat will operate Zone 1 - If priority is OFF, 120 VAC power must be supplied to the green ZC and N connections for the pumps to operate 8. Wire the 120 VAC power output to the priority zone pump from L (Hot), N (Neutral) terminals labeled, PRIORITY PUMP1. The priority zone is typically used for a domestic hot water (DHW) demand. 3.7

16 Section 3 Device Installation 9. Wire each successive pump to zone pumps as needed. Each ground terminal can support 2 ground wires for convenience VAC power output is also available for a primary pump depending on the hydronic circuit design. 11. Terminals XX are closed any time there is a thermostat call to the wiring center. These may be wired directly to the thermostat connection on the boiler TT. Note, that if an AX10RF Receiver (sold separately) is used and configured as RX1, the XX terminals aren t used. Priority Zone Function (Master wiring center only) When the PRIORITY dip switch is set to the ON position the following occurs: - Zone 1 pump is turned ON and all other pumps, including those on SLAVE wiring centers, are turned OFF - If the Zone 1 demand continues for more than 1 hour, the control will override Zone 1 priority and allow the other zone pumps to operate when a heat demand is present - Once the Zone 1 demand is satisfied, the priority override feature resets and a Zone 1 heat demand will, again, take priority over the other zones. 12. The terminals labeled Zone 1 E/S are powered any time the Zone 1 thermostat is closed, and the PRIORITY dip switch is in the ON position. These terminals are to be wired to the DHW demand input of the boiler to change the target temperature. Under these conditions, none of the other pumps will operate. Thermostat Connection If the priority zone is used on the AKL04/06PRF Wiring Center with a wired room thermostat that requires separate C terminal, it should be wired as shown in the drawing. For a DHW thermal switch, a contact closure across R & W will initiate a demand. 13. Reattach the control cover securing it with the 4 screws and switch on 120 VAC power to the unit. The LED labeled POWER will be illuminated. 3.8

17 Section 3 Device Installation AKL08RF Zone Valve Wiring Center Installation The SALUS AKL08RF Zone Valve Wiring Center connects with AS20WRF/BRF Wireless Thermostats via the AC10RF Coordinator or SG888ZB Gateway to control up to 32 actuators in 8 zones. It also provides power switching to a system circulator and a wired output for heat demand to a boiler. Note that the maximum total amp draw for the zone valve actuators is 3.3 amps. The AKL08RF Zone Wiring Center must be installed by a qualified contractor. Installation and repairs are to be performed according to all national and local codes required by the authority having jurisdiction. In the absence of local requirements, follow ANSI/NFPA 70, National Electrical Code. Failure to follow these requirements may lead to severe personal injury, death or major property damage. DO NOT SERVICE this equipment without disconnecting the AC electrical power. 1. Carefully read these instructions and all instructions supplied with the unit before starting the installation. 2. Inspect the control for damage and be sure all required parts are included before beginning. 3. Remove the cover by turning the screw to the unlock position ¼ turn. 4. Unscrew two screws in the black line voltage cover and remove it. 5. Disconnect the 24 VAC supply connection. 6. Unscrew two screws on the left side of the control and remove the white internal wiring base. 7. Attach the AKL08RF Zone Valve Wiring Center to the wall in the desired suitable location. DO NOT INSTALL this control in an area where water leaks or spray are possible. Failure to comply may result in serious injury, death or major property damage due to electrocution or fire. 8. Using appropriate wire connectors & strain relief fittings (not included) for the knock-out connections in the case, connect the 120 VAC power supply to the terminals provided. 9. Terminals 1 & 2 under the line voltage cover connect to a dry contact for the 120 VAC circulator. Voltage through this contact is not to exceed 250 VAC and the current is to be 10 amps or less. Press the clamp with a small screwdriver Insert the stripped wire end in the terminal Release the clamp Pull gently on the wire to make sure it is secure 10. Re-attach the white wiring base by inserting the tab on the right side into the base and securing it with the 2 screws on the left, making sure the power lines are not pinched. Use the grooves provided in the wiring base for managing the pump and boiler wires. They provide a path for wires under the wiring base to the case knock-out openings. 3.9

18 Section 3 Device Installation The boiler can be controlled wirelessly by the AKL08RF Zone Valve Wiring Center if an AX10RF Receiver, configured as RX1 (sold separately) is used with the system. However, if desired, the boiler s thermostat input terminals (TT or RT) can be wired directly to terminals labeled 3 & 4 on the Wiring Center. 11. If desired, connect wires from terminals 3 & 4 under the cover to the boiler thermostat (TT) connection to provide a boiler demand. Press the clamp with a small screwdriver Insert the stripped wire end in the terminal Release the clamp Pull gently on the wire to make sure it is secure 12. Attach up to 4 zone valve actuators to each zone by inserting the stripped wire ends into the round holes provided. To release a wire, use a small screwdriver to push the release mechanism next to each hole. Pull gently on the wires after they are inserted to be sure they are secure. Use the grooves provided in the wiring base for managing the valve wires. They provide a path for wires under the wiring base to the case strain relief openings. 13. Re-attach the 24 VAC supply connection. 14. Check the fuse by removing the fuse holder and making sure the correct fuse is installed (4A) 15. Re-attach the line voltage cover by inserting 2 tabs on the right side into the wiring base and securing the screws. 16. Set the actuator jumper for the correct action. The default position is for normally closed (NC) actuators. To change to normally open (NO) move the jumper to the right and center pin. 17. Set the pump/boiler off delay jumper for the correct setting. The default setting is for no delay. To change the pump/boiler off delay to 15 minutes, move the jumper to the right and center pin. 18. Re-attach the unit cover by inserting the tabs on the right side into the unit and securing it with the ¼ turn latch. 3.10

19 Section 3 Device Installation AX10RF Receiver Installation The AX10RF Receiver can be configured as a system remote boiler switch (RX1) or a single channel output to a thermal actuator or zone valve. The AX10RF Receiver must be installed by a qualified contractor. Installation and repairs are to be performed according to all national and local codes required by the authority having jurisdiction. In the absence of local requirements, follow ANSI/NFPA 70, National Electrical Code. Failure to follow these requirements may lead to severe personal injury, death or major property damage. DO NOT SERVICE this equipment without disconnecting the AC electrical power. 1. Carefully read these instructions and all instructions supplied with the unit before starting the installation. BOILER RX1 24 VAC SUPPLY 2. Inspect the control for damage and be sure all required parts are included before beginning. 3. Remove the cover by loosening the 2 screws on the bottom of the unit and rotating the bottom upward until the top clips disengage. CH DEMAND RX2 NO COM AX10RF WIRING SCHEMATIC RX1 CONFIGURATION FOR BOILER SWITCH H H N N AX10RF RECEIVER 4. Attach the AX10RF Receiver to the wall in the desired suitable location. BOILER 24 VAC SUPPLY DO NOT INSTALL this control in an area where water leaks or spray are possible. Failure to comply may result in serious injury, death or major property damage due to electrocution or fire. CH DEMAND RX1 RX2 NO COM H H N N AX10RF RECEIVER 5. Slide the configuration switch on the back of the cover to the desired position: AX10RF WIRING SCHEMATIC RX2 CONFIGURATION FOR ZONE VALVE Z ZONE VALVE RX1 for system remote boiler switch RX2 for valve actuator output 6. Wire the receiver using the appropriate schematic diagram. 7. Re-attach the cover by engaging the cover clips with the top of the unit and rotating downward until it closes. 8. Fasten the screws at the bottom of the unit. 3.11

20 Section 3 Device Installation ARV10RFM Radiator Valve Actuator Installation The ARV10RFM-3 Radiator Valve Actuator attaches to a Thermostatic Radiator Valve (TRV) that can connect wirelessly with your SALUS system to control room temperature. 1. Carefully read these instructions and all instructions supplied with the unit before starting the installation. 2. Inspect the control for damage and be sure all required parts are included before beginning. 3. Check the compatibility of this actuator with your TRV. If threads are not visible a SALUS RA adapter (included) may work with the valve. 4. Press up on the spring latch of the battery compartment and insert 2 AA batteries (included) ensuring the correct orientation. The LED on the top of the unit will flash green and then turn solid red. 5. Install the actuator on the radiator valve using the RA adapter if needed. Screw the unit (finger tight) to the radiator valve and check that the LED remains solid red. 6. Press any button on the unit to adapt it to the radiator valve. Once all movement and LED activity has stopped, the unit is ready to pair with your AS20 Thermostat. AFTER THE LED is off, listen for further activity from the ARV10RFM to be sure that it has completed its calibration cycle before advancing to the pairing step in Section 4. Failure to complete the calibration cycle may cause the installer to be required to reset the ARV10RFM Radiator Valve Actuator (Section 5) and re-initiate the calibration sequence by repeating the steps above. 3.12

21 3.13

22 Section 4 Device Pairing & Setup with Internet Connection SALUS wireless systems can be configured with an internet connection using the SG888ZB Gateway, or without an internet connection using the AC10RF Coordinator. It is important to follow the instructions that correspond to the desired configuration in the following pages. The configurations will be clearly marked, With Internet Connection or Without Internet Connection. System Configuration with Internet Connection using SG888ZB Gateway Before beginning the system configuration, be sure that the SALUS Smart Home application is downloaded to your mobile device. Links to the appropriate ios or Android application are included in Section 2, System Overview or on the SALUS website. You should have a username & password for this application. Be sure to keep this information secure. 1. Open the SALUS Smart Home application on your mobile device. If you haven t already done so, log on with your username and password. As noted in Section 3, Device Installation, the LED ring on the SG888ZB Gateway should be blue. The default SALUS Smart Home application screen includes a brief explanation of the dashboard. Once you understand this message, chose the x in the upper right corner to remove it. 2. Select Add new gateway from the SALUS Smart Home dashboard. A welcome screen appears showing Activate your gateway prompting you to make sure your gateway is connected to the router with an ethernet cable and the LED light is solid blue. 3. Press the multi button on top of the SG888ZB Gateway once, so it flashes green. 4.1

23 Section 4 Device Pairing & Setup with Internet Connection 4. The device serial number is automatically entered and boxes appear to enter: Country (Canada/USA), Time Zone (Nearest City), Time Format (12h/24h), LED Mode (Always On/ Time Out), Address and Gateway Name. Note that you have 2 minutes to enter all the parameters before it deletes the serial number and times out. In this event, press the back button until Add new gateway screen is displayed and repeat steps 3 & Once the Activate my gateway button is pressed, the device firmware is automatically updated. When a message is displayed saying Your Gateway is Up To Date press, Next. Your SG888ZB Gateway will now be activated. 6. Select the orange button on the lower part of the screen labeled, Connect Equipment. The program will then advance to a button labeled, Scan for equipment. You are now ready to pair your components with the system. Any time it is necessary to add components to the system, you can return to the Scan for equipment button by selecting the drop down menu from the upper right side of the screen. Then select: Equipment All Equipment Add Equipment Scan for Equipment 4.2

24 Section 4 Device Pairing & Setup with Internet Connection AS20WRF/BRF Thermostat Configuration Prior to pairing, the AS20WRF/BRF Thermostat should be set to the desired configuration. The default configuration for the thermostat is programmable (Pr o9) but it can also be configured as non-programmable (np r9). Note that earlier firmware may display (di 9t) for the non-programmable configuration. The non-programmable option is used for thermostats intended to be a member of a thermostat group, part of an internet connected system, or a system where a schedule is not desired. 1. Use or keys to select between Pr o9 (programmable) and np r9 (nonprogrammable) thermostat configurations. (Note: Skip the uu tr selection as this is not applicable) 2. Press to confirm selection. Once the AS20WRF Thermostat is properly configured, pairing with other devices may proceed. Note: The uu tr configuration is not used and should not be selected. The AS20WRF/BRF Thermostat configuration cannot be changed after pairing is completed without resetting it to factory defaults and starting over. DO NOT PROCEED with pairing until the thermostat is in the desired configuration. If the wrong configuration is chosen prior to pairing, press & hold the, & buttons to re-enter the Pr o9 mode. 4.3

25 Section 4 Device Pairing & Setup with Internet Connection The AS20WRT Thermostat can be paired with four types of devices: Display Code SALUS Model AKL01PRF 1 Zone Pump Wiring Center (Default) Note: Older firmware may display UF H instead of rl AY AKL04PRF 4 Zone Pump Wiring Center AKL06PRF 6 Zone Pump Wiring Center AKL08RF 8 Zone Valve Wiring Center ARV10RFM Radiator Valve AX10RF System Receiver configured (RX1) Boiler Operation AX10RF System Receiver configured (RX2) Zone Valve 4.4

26 Section 4 Device Pairing & Setup with Internet Connection AS20WRF/BRF Thermostat with AKL01/04/06PRF and AKL08RF Wiring Centers To begin pairing, all of the required components are to be powered: AS20WRF Thermostat, AKL Wiring Center and AX10RF Receiver (if desired for boiler demand switching RX1). The LED ring on the SG888ZB should be solid blue. The Network Status LED on the AKL Wiring Center should be flashing and, if a AX10RF Receiver is used, the LED back light on the Auto/Manual switch should be flashing red. 1. Open the SALUS Smart Home mobile application and select the drop down menu from the upper right side of the screen select: Equipment All Equipment Add New Equipment Scan for Equipment The SG888ZB Gateway will begin flashing red while it is searching for the devices. This will continue until the pair process is complete. The Network Status LED on the AKL Wiring Center (red on the AKL01/04/06PRF and green on the AKL08RF) will flash. If an AX10RF Receiver is used, the LED backlight on the Auto/Manual switch will be flashing red. 4.5

27 Section 4 Device Pairing & Setup with Internet Connection 2. Select the check boxes for both the Wiring Center and the Zigbee Receiver on the SALUS Smart Home application. Then press the orange Connect equipment button. 3. Give each device a descriptive name that allows easy identification. If there are multiple wiring centers, identify each with respect to its location or purpose. 4. Press Finish and the flashing red LED lights on both devices should stay solid red. This indicates they are connected to the system. 5. Once the Wiring Center is connected and the LED on the SG888ZB stops flashing, press the multi button for two seconds. Zone LED on the AKL Wiring Center will illuminate indicating the ID number of the device. Use this number when setting up the AS20WRF/BRF Thermostats to address the correct Wiring Center. AKL Wiring Center ID Number Key ID # Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone Press confirm on the AS20WRF/BRF Thermostat to advance from the Screen. The AS20WRF/BRF Thermostat goes through it s boot sequence. 7. Again, from the SALUS Smart Home mobile application and select the drop down menu from the upper right side of the screen select Equipment All Equipment Add New Equipment Scan for Equipment 4.6

28 Section 4 Device Pairing & Setup with Internet Connection 8. When pairing begins, the AS20WRF/BRF Thermostat displays at the bottom of the screen. Press confirm to continue. The selection is used for all of the Wiring Centers. 9. When the screen reads it will be visible in the SALUS Smart Home application. Pressing confirm to proceed with the AS20WRF/BRF Thermostat setup. 10. Select the Zigbee Digital Control Thermostat, checking the box. Press the Connect equipment button. 11. Give each thermostat a descriptive name that differentiates it from others in the network and press Next. 12. Pressing the icon advances to thermostat setup. However, this can be completed later. Finish to complete the connection to the wireless network. 4.7

29 Section 4 Device Pairing & Setup with Internet Connection Next we will complete the AS20WRF/BRF setup sequence. 13. Wiring Center Number: Use the or buttons to choose the Wiring Center number if there are more than one in the system. Then press confirm. 14. Group Number: Group numbers are not applicable to wireless systems connected to the internet. Leave blank for this parameter. 15. Zone Number: Use the or buttons to choose the heating zone to which the AS20WRF/BRF Thermostat is to be associated. Then press confirm. The Group setting is not used for wireless systems connected to the internet. For information on using Groups, see the section entitled AS20WRF/BRF Pairing without Internet Connection. If multiple identical components are used, it is important to give each a unique identification. For example, if more than one AS20WRF/BRF Thermostat is used, name each one for the zone with which it is associated. For example, AS20WRF-1st Floor helps to identify which thermostat you are interacting with when you use the application. 16. Once the pairing is complete, the AS20WRF/BRF Thermostat shows the current time & temperature. Increase the temperature setpoint above the current temperature to test operation. The zone light corresponding with the thermostat being tested should come on. If an AX10RF Receiver is used, the backlight behind the Auto/Manual switch will be solid green, indicating that a demand signal is going to the boiler. Check to be sure the boiler starts when this demand is present. When the thermostat is successfully paired, the screen on the AS20WRF/BRF Thermostat will display the current time and temperature, the Network Status light on the AKL-RF Series Wiring Center will be solid green and, if applicable, the LED back light on the AX10RF Receiver s Auto/Manual switch will appear solid red. The LED ring on the SG888ZB Gateway will be solid blue. 4.8

30 Section 4 Device Pairing & Setup with Internet Connection LED is solid red. Auto Manual On Off PM Choosing the AKL Wiring Center device under the All Equipment menu on the SALUS Smart Home mobile application and pressing the Identify icon will cause the RED G1 & G2 on the device to flash. Similarly, pressing the Identify icon for the AX10RF device will cause the green LED backlight on the On/Off button to flash. AS20WRF/BRF Thermostat with ARV10RFM Radiator Valve Actuator To begin pairing, all of the required components are to be powered: AS20WRF/ BRF Thermostat, ARV10RFM Radiator Actuator and AX10RF Receiver (if desired for boiler demand switching RX1) and the LED ring on the SG888ZB is solid blue. The LED indicator on the Actuator should be off. BEFORE PROCEEDING, Listen to the ARV10RFM to be sure there is no motor activity. If a AX10RF Receiver is used, the LED back light on the Auto/Manual switch should be flashing red. DO NOT BEGIN pairing with the ARV10RFM Radiator Valve Actuator unless the light is out and there is no motor activity. Listen closely to the Valve Actuator to be sure it is not operating before proceeding. 4.9

31 Section 4 Device Pairing & Setup with Internet Connection 1. Open the SALUS Smart Home mobile application and select the drop down menu from the upper right side of the screen select: Equipment All Equipment Add New Equipment Scan for Equipment The SG888ZB Gateway will begin flashing red while it is searching for the devices. This will continue until the pair process is complete. The AS20 Thermostat must be set to for it to appear on the SALUS Smart Home application. COMPLETE step 3 before proceeding with pairing the ARV10RFM Radiator Actuator. 2. Use the Up arrow to change to from to. 3. Then press confirm. The ASWRF Thermostat will become visible on the SALUS Smart Home application 4. When the AS20WRF/BRF Thermostat displays, press confirm. 5. When the display shows, press confirm. 4.10

32 Section 4 Device Pairing & Setup with Internet Connection 6. Select the Zigbee Digital Control Thermostat, checking the box. Press the Connect equipment button. 7. Give each thermostat a descriptive name that differentiates it from others in the network and press Next. 8. Pressing the icon advances to thermostat setup. However, this can be completed later. Finish to complete the connection to the wireless network. 10 seconds The LED indicator will flash red. 9. Press and hold the pair button for 10 seconds to enter pairing mode on each actuator to be connected. 4.11

33 Section 4 Device Pairing & Setup with Internet Connection 11. From the SALUS Smart Home application, select the thermostat with which the ARV10RFM Radiator Valve Actuators are to be associated The SALUS wireless system allows up to 6 actuators to communicate with one AS20WRF/BRF thermostat. All ARV10RFM Radiator Valve Actuators to be associated with a single thermostat MUST BE IN PAIRING MODE before finalizing the AS20WRF/BRF setup. 12. Press the thermostat name to enter the configuration menu. 13. Select the tool next to All TRV s on This Thermostat 14. Press scan for equipment and check all boxes for ARV10RFM Actuators to be connected. 15. Give each ARV10RFM Actuator a unique name 16. Check off all actuators to be connected (The box turns green when selected) All ARV10RFM Actuators will be listed under All TRV s on This Thermostat 4.12

34 Section 4 Device Pairing & Setup with Internet Connection When the AS20WRF/BRF Thermostat is successfully paired, the screen will display the current time and temperature, the LED indicator on the on the ARV10RFM Radiator Valve Actuator turn off and, if applicable, the LED back light on the AX10RF Receiver s Auto/Manual switch will appear solid red. The LED on the SG888ZB Gateway will be solid blue. LED is off. LED is solid red. Auto Manual On Off PM Choosing the ARV10RFM device under the All Equipment menu on the SALUS Smart Home mobile application and pressing the Identify icon will cause the green LED on the device to flash. 4.13

35 Section 4 Device Pairing & Setup with Internet Connection AS20WRF/BRF Thermostat with AX10RF Receiver for Boiler Switching (RX1) Be sure the switch on the inside cover of the AX10RF Receiver has been configured to RX1, for boiler demand switching, and the Receiver has been wired as indicated in Section 3, Installation. To begin pairing, all of the required components are to be powered: AS20WRF/BRF Thermostat and AX10RF Receiver. The LED ring on the SG888ZB Gateway should be solid blue, indicating it is connected to the internet. The switches on the cover of the Receiver should be in Auto and On positions respectively. Pairing the AX10RF in the RX1 configuration with an AS20WRF/BRF Thermostat is only required when used in a 1 to 1 relationship without an AKL Wiring Center. Each system will only support one AX10RF configured as RX1 and one configured as RX2. 1. Open the SALUS Smart Home mobile application and select the drop down menu from the upper right side of the screen select: Equipment All Equipment Add New Equipment Scan for Equipment 4.14

36 Section 4 Device Pairing & Setup with Internet Connection The SG888ZB Gateway will begin flashing red while it is searching for the devices. This will continue until the pair process is complete. 2. Use the Up arrow to change to from to. 3. Then press confirm. The AS20WRF/BRF Thermostat will become visible on the SALUS Smart Home application PM When Thermostat displays, press confirm. 5. When the display shows, press confirm. The AS20WRF/BRF Thermostat will display the current temperature, time and icon showing temperature mode. 4.15

37 Section 4 Device Pairing & Setup with Internet Connection 6. On the SALUS Smart Home application, check the boxes for both the AX10RF Receiver and the AS20WRF/ BRF Thermostat. Press the Connect equipment button. 7. Enter a name for both devices. Remember to name similar devices appropriately to prevent confusion when accessing them remotely. Digital Thermostats should describe the space that they are servicing. 8. Press Finish to complete the pairing operation. The AS20BRF Thermostat description will appear on your SALUS Smart Home home screen. 9. Once the display shows the current temperature, confirm that the LED back light on the Auto/Manual switch is a constant red. The AX10RF Receiver is now paired. Auto Manual On Off 4.16

38 Section 4 Device Pairing & Setup with Internet Connection AS20WRF/BRF Thermostat with AX10RF Receiver for Zone Valve Operation (RX2) Be sure the switch on the inside cover of the AX10RF Receiver has been configured to RX2, for zone valve operation and the receiver has been wired as indicated in Section 3, Installation. Each wireless system will support only one receiver in RX1 mode and one in RX2 mode. These two components can be used together to provide boiler switching and zone valve operation. Auto On Manual Off 1. Open the SALUS Smart Home mobile application and select the drop down menu from the upper right side of the screen select: Equipment All Equipment Add New Equipment Scan for Equipment The SG888ZB Gateway will begin flashing red while it is searching for the devices. This will continue until the pair process is complete. 4.17

39 Section 4 Device Pairing & Setup with Internet Connection 2. Use the Up arrow to change to from to. 3. Then press confirm. The AS20WRF/BRF Thermostat on the SALUS Smart Home application PM 4. When Thermostat displays, press confirm. 5. When the display shows, press confirm. The AS20WRF/BRF Thermostat will display the current temperature, time and icon showing temperature mode 4.18

40 Section 4 Device Pairing & Setup with Internet Connection 6. On the SALUS Smart Home application, check the boxes for both the AX10RF Receiver and the AS20WRF/ BRF Thermostat. Press the Connect equipment button. 7. Enter a name for both devices. Remember to name similar devices appropriately to prevent confusion when accessing them remotely. Digital Thermostats should describe the space that they are servicing. 8. Press Finish to complete the pairing operation. The AS20BRF Thermostat description will appear on your SALUS Smart Home home screen. 9. Once the display shows the current temperature, confirm that the LED back light on the Auto/Manual switch is a constant red. The AX10RF Receiver is now paired. Auto Manual On Off 4.19

41 Section 5 Device Pairing & Setup without Internet System Configuration without Internet Connection using AC10RF Coordinator Before beginning system configuration without an internet connection, be sure that the AC10RF Coordinator is powered and the LED is solid red. Prior to using the AC10RF Coordinator with an AKL01/04/06PRF Wiring Center, update the firmware version as follows: 1.Use a computer with an internet connection that meets the following requirements: COMPUTER PC Mac OPERATING SYSTEM Windows 8 or later OSX or later USB PORT Type A Type A 2. Connect to the SALUS Update Tool ( 3.Download and run the Update Tool by following the onscreen prompts 4. Insert the AC10RF Coordinator into a USB port on the computer when prompted to do so AS20WRF/BRF Thermostat Configuration Prior to pairing, the AS20WRF/BRF Thermostat should be set to the desired configuration. The default configuration for the thermostat is programmable (Pr o9) but it can also be configured as non-programmable (np r9). Note that earlier firmware may display (di 9t) for the nonprogrammable configuration. The non-programmable option is used for thermostats intended to be a member of a thermostat group. 1. Use or keys to select between Pr o9 (programmable) and np r9 (non-programmable thermostat configurations.. 2. Press to confirm selection. Once the AS20WRF/BRF Thermostat is properly configured, pairing with other devices may proceed. Note: The configuration is not used and should not be selected. The AS20WRF/BRF Thermostat cannot be configured as a digital thermostat after pairing without resetting it to factory defaults and starting over. DO NOT PROCEED with pairing until the thermostat is in the desired configuration. 5.1

42 Section 5 Device Pairing & Setup without Internet AS20WRF/BRF Thermostat with AKL01/04/06PRF or AKL08RF Wiring Center To begin pairing, all of the required components are to be powered: AS20WRF/ BRF Thermostat, AKL Wiring Center and AX10RF Receiver configured RX1 for boiler demand (optional). The Network Status LED on the AKL Wiring Center should be flashing and, if the AX10 RF Receiver is used, the red backlight behind the Auto/Manual switch should also be flashing. 1. Press and hold the lighted red button on the AC10RF Coordinator for 5 seconds, until the LED begins flashing, to begin pairing. When the network status LED on the AKL Wiring Center and the backlight on the Auto/Manual button of the AX10RF Receiver (if used) stop flashing, they have been paired and you are ready to pair the AS20WRF/BRF Thermostat. If the network status LED on the AKL Wiring Center continues blinking, turn off the power to the device for 10 seconds. 2. Once the network status LED on the AKL Wiring Center is no longer flashing, press the pairing button on the AC10RF Coordinator for two seconds. Zone LED on the Wiring Center will illuminate the ID number of the device (see ID# key below) AKL Wiring Center ID Number Key ID # Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone

43 Section 5 Device Pairing & Setup without Internet 3. After choosing the correct thermostat configuration, the AS20WRF/BRF Thermostat displays rl AY at the bottom of the screen. Press to continue. The rl AY selection is used for all AKL Wiring Centers. Note: that older firmware may display UF H instead of rl AY 4. When the screen reads, press confirm to proceed with the AS20WRF/BRF Thermostat setup. 5. Wiring Center Number: Use the or buttons to choose the Wiring Center number if there are more than one in the system. Then press confirm. 6. Group Number: If grouped thermostats are used, use the up arrow to choose either group 1 or 2. If no groups are used, leave blank for this parameter. 7. Zone Number: Use the or buttons to choose the heating zone to which the AS20WRF/BRF Thermostat is to be associated. Then press confirm. 5.3

44 Section 5 Device Pairing & Setup without Internet Record the Wiring Center zone number that flashes after pushing the pairing button to identify the wiring center. (Zone 1 = Wiring Center 1, Zone 3 = Wiring Center 3) Refer to the wiring center installation documentation for identification of wiring centers that exceed the number of zones. 8. Repeat steps 2-6 for each additional AS20WRF/BRF Thermostat. 9. When all AS20WRF/BRF thermostats have been set up, press & hold the flashing button on the AC10RF Coordinator to complete pairing. The button light will stop flashing and stay solid red. When the thermostat is successfully paired, the screen on the AS20WRF/BRF Thermostat will display the current temperature, the Network Status Light on the AKL-RF Series Wiring Center will be solid red and, if applicable, the LED back light on the AX10RF Receiver s Auto/Manual switch will appear solid red. The LED button on the AC10RF Coordinator will be solid red PM LED is solid red. Auto Manual On Off Use the Identify Mode to check system communication and configuration. 1) Press and release the AC10RF Coordinator button to enter Identify Mode. The light will flash green. Each item connected will give an indication that it is connected. a. AKL-RF Wiring Center G1 & G2 flash red b. AX10RF Receiver On/Off Switch backlight flashes green c.. AS20WRF/BRF Thermostat Displays a 10 minute countdown with the letters id below it until identify times out. 2) Press and release the AC10RF Coordinator button to exit Identify Mode. The light will change to solid red indicating that the network is active To delete all devices from the network the following procedure should be used by a qualified contractor. 1) Press and hold the AC10RF Coordinator button for 10 seconds until the light turns AMBER. 2) Once the devices have been deleted, they can be re-installed using the procedures in this manual. 5.4

45 Section 5 Device Pairing & Setup without Internet AS20WRF/BRF Thermostat with ARV10RFM Radiator Valve Actuator Before beginning the pairing process, it is important to be sure that the ARV10RFM Radiator Valve Actuator was installed and adapted correctly as detailed in Section The batteries are to be inserted and the LED is to be solid red before installing the actuator on the radiator valve. Remember the actuator should be only finger tight on the valve. Using pliers or other tools can damage the assembly. 2. After attaching the actuator to the valve, press any of the buttons to initialize the actuator. This process may take several minutes and the valve may continue to initialize after the light is no longer illuminated. DO NOT BEGIN pairing with the ARV10RFM Radiator Valve Actuator unless the light is out and there is no motor activity. Listen closely to the Valve Actuator to be sure it is not operating before proceeding. 3. Press and hold the lighted red button on the AC10RF Coordinator for 5 seconds, until the LED begins flashing, to begin pairing. 4. Use the Up arrow to change to from to. 5. Then press confirm. The AS20WRF/BRF Thermostat will join the wireless network and begin the pairing sequence. 10 seconds The LED indicator will flash red. 6. Press and hold the pair button for 10 seconds to enter pairing mode. 5.5

46 Section 5 Device Pairing & Setup without Internet Each AS20WRF/BRF Thermostat is capable of controlling up to 6 ARV10RFM Actuators. All Actuators intended for pairing with a single thermostat are to be in pairing mode before proceeding 7. When the AS20WRF/BRF Thermostat displays, press confirm. 8. Press right arrow to begin scanning for ARV10RFM Actuators that are in the pairing mode. 9. Once all Actuators have been scanned, press on the AS20WRF/ BRF Thermostat to pair the valves with the Thermostat. 10. When all Thermostatic Regulator Valves (TRV) have been set up, press & hold the pairing button on the AC10RF Coordinator or the multi button on the SG888ZB Gateway to complete pairing. When the AS20WRF/BRF Thermostat is successfully paired, the screen will display the current temperature, the LED indicator on the ARV10RFM Radiator Valve Actuator turn off and, if applicable, the LED back light on the AX10RF Receiver s Auto/Manual switch will appear solid red. The LED on the AC10RF Coordinator will be solid red. If the SG888ZB Gateway is used without an internet connection, the LED ring on the multi button will be solid red. LED is off. LED is solid red. Auto Manual On Off PM Use the Identify Mode to check system communication and configuration. 1) Press and release the AC10RF Coordinator button to enter Identify Mode. The light will flash green. Each item connected will give an indication that it is connected. a. AKL-RF Wiring Center G1 & G2 flash red b. AX10RF Receiver On/Off Switch backlight flashes green c. AS20WRF/BRF Thermostat Displays a 10 minute countdown with the letters id below it until identify times out. 2) Press and release the AC10RF Coordinator button to exit Identify Mode. The light will change to solid red indicating that the network is active 5.6

47 Section 5 Device Pairing & Setup without Internet AS20WRF/BRF Thermostat with AX10RF Receiver for Boiler Switching (RX1) Be sure the switch on the inside cover of the AX10RF Receiver has been configured to RX1, for boiler demand switching, and the Receiver has been wired as indicated in Section 3, Installation. To begin pairing, all of the required components are to be powered: AS20WRF/BRF Thermostat and AX10RF Receiver. The lighted LED button on the AC10RF Coordinator should be solid red. The switches on the cover of the Receiver should be in Auto and On positions respectively. Pairing the AX10RF in the RX1 configuration with an AS20WRF/BRF is only required when used in a 1 to 1 relationship without an AKL Wiring Center or other system device. Each system will only support one AX10RF configured as RX1 and one configured as RX2. 1. Press and hold the lighted red button on the AC10RF Coordinator for 5 seconds, until the LED begins flashing, to begin pairing. 2. Use the Up arrow to change to from to. 3. Then press confirm. The AS20WRF/BRF Thermostat will join the wireless network and begin the pairing sequence. 5.7

48 Section 5 Device Pairing & Setup without Internet PM 4. When Thermostat displays, press confirm. 5. When the display shows, press confirm. The AS20WRF/BRF Thermostat will display the current temperature and an icon showing the temperature mode. 6. Once the display shows the current temperature, confirm that the LED back light on the Auto/ Manual switch is a constant red. The AX10RF Receiver is now paired. Auto Manual On Off AS20WRF/BRF Thermostat with AX10RF Receiver for Zone Valve Operation (RX2) Be sure the switch on the inside cover of the AX10RF Receiver has been configured to RX2, for zone valve operation and the receiver has been wired as indicated in Section 3, Installation. To begin pairing, all of the required components are to be powered: AS20WRF/BRF Thermostat and AX10RF Receiver. The lighted LED button on the AC10RF Coordinator should be solid red. The switches on the cover of the Receiver should be in Auto and On positions respectively. Each wireless system will support only one receiver in RX1 mode and one in RX2 mode. These two components can be used together to provide boiler switching and zone valve operation. 5.8

49 Section 5 Device Pairing & Setup without Internet 1. Press and hold the lighted red button on the AC10RF Coordinator for 5 seconds, until the LED begins flashing, to begin pairing. 2. Use the Up arrow to change to from to. 3. Then press confirm. The AS20WRF/BRF Thermostat join the wireless system PM 4. When Thermostat displays, press confirm. 5. When the display shows, press confirm. The AS20WRF/BRF Thermostat will display the current temperature and an icon showing the temperature mode. 6. Once the display shows the current temperature, confirm that the LED back light on the Auto/Manual switch is a constant red. The AX10RF Receiver is now paired. Auto On Manual Off 5.9

50 Section 6 Resetting Factory Defaults If changes to the wireless setup are required, components in SALUS wireless systems can be reset to factory defaults. Resetting the SG888ZB Gateway with Internet Connection 1. Open the SALUS Smart Home mobile application and select the drop down menu from the upper right side of the screen. 2. Select Equipment All Equipment. A list of connected equipment is displayed. 3. Select the icon that represents the SG888ZB Gateway and scroll to the bottom of the information screen. 4. Select Remove universal gateway. The application will request confirmation that you want to delete it. 6.1

51 Section 6 Resetting Factory Defaults Resetting the SG888ZB Gateway without Internet Connection To reset the SG888ZB Gateway to factory defaults without an internet connection: 1. Press and hold the multi button on top of the SG888ZB Gateway. 2. When the LED flashes red, release the multi button. After approximately 10 seconds, the LED ring turns solid red indicating the default values are loaded. All the devices connected to the gateway will be deleted from the network and must be re-installed as previously described. Without an internet connection, the SG888ZB Gateway will remain solid red. Resetting the AC10RF Coordinator without Internet Connection 1. Press and hold the pairing button on the AC10RF Coordinator for 10 seconds 2. The LED light on the AC10 Coordinator will turn amber, indicating the system is resetting. 3. When the system is reset, the LED light will turn red once again, indicating the system is ready. All the devices connected to the gateway will be deleted from the network and must be re-installed as previously described. 6.2

52 Section 6 Resetting Factory Defaults Resetting the AS20WRF/BRF Thermostat without Internet Connection PM 1. To reset the AS20WRF/BRF Thermostat, Simultaneously, press and hold the, & buttons. 2. When the screen showing PS uu at the bottom appears, press the up arrow to increase the number to When the number 47 is shown on the LCD screen, press confirm ( ). de L then shows on the screen. 4. Press confirm again to reset the Thermostat. 5. Once AE 5 appears on the screen, press confirm once more to go through the boot sequence. 6.3

53 Section 6 Resetting Factory Defaults Resetting the AKL01/04/06PRF Zone Pump or AKL08RF Zone Valve Wiring Center without Internet Connection To reset the AKL Wiring Centers, locate the Pair button on the top of the cabinet near the cover screw on the right side. 1. Press and hold the Pair button for about 20 seconds until the G1/G2 lights start flashing. After releasing the button, the network status light begins flashing 2. To complete the reset, cycle the power to the Wiring Center off for 10 seconds. The AKL Wiring Center WILOT OPERATE correctly until the power is cycled off and on. with Internet Connection To reset the AKL Wiring Centers, delete them from the SALUS Smart Home mobile application as follows: 1. Select the menu from the upper right of the home screen. 2. Choose Equipment 3. Then choose, All equipment 4. Choose the appropriate Wiring Center from the list. 5. Scroll to the bottom of the screen. 6. Select Remove Wiring Center. 7. Once the AKL Wiring Center is removed, be sure to cycle off the power for more than 10 seconds to fully reset the unit. 6.4

54 Section 6 Resetting Factory Defaults Resetting the AX10RF Receiver without Internet Connection The AX10RF Receiver has 2 reset buttons on the bottom surface of the unit cover. The right button is for the receiver and the left is for the system. 1. Using a small stiff wire, press and hold the right reset button until the red auto/manual backlight LED flashes. 2. Using the same probe, press and hold the left reset button until the red auto/manual backlight LED and the green on/off backlight LED flash alternately. 3. To complete the reset, cycle the power to the AX10RF Receiver off for 10 seconds. with Internet Connection To reset the AX10RF Receiver, delete the icon from the SALUS Smart Home mobile application in the same way as the Wiring Centers: 1. Select the menu from the upper right of the home screen. 2. Choose Equipment 3. Then choose, All equipment 4. Choose the appropriate Wiring Center from the list. 5. Scroll to the bottom of the screen. 6. Select Remove Wiring Center. 7. Once the AKL Wiring Center is removed, be sure to cycle off the power for more than 10 seconds to fully reset the unit. 6.5

55 Section 6 Resetting Factory Defaults Resetting the ARV10RFM Radiator Valve Actuator without Internet Connection 1. Press and hold all three buttons on the ARV10RFM Valve Actuator for 30 seconds. The light will flash amber. 2. Open the battery compartment and remove one of the batteries. 3. Reinsert the battery. The ARV10RFM Valve Actuator is now, once again, ready for pairing with an AS20WRF/BRF Thermostat. 6.6

56 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat User Interface Key M12 A 1 ON OFF B AM PM # Icon Function 1 Indicates active heating mode. 2 Sun: high comfortable temperature 3 Cloudy: middle comfortable temperature 4 Moon: low comfortable temperature 5 Programmable thermostat Program mode (Auto) indicator: Indicates program is running, Auto On or Auto Off. 6 Party mode indicator 7 Vacation temperature indicator 8 Defrost temperature mode indicator 9 Heating is on 10 Wifi/network indicator: unit is connected to Zigbee network 11 Internet indicator: unit is linked to the Internet 12 Cooling mode; flashes when cooling is running 13 Hot water indicator - thermostat is in Hot Water mode 14 Hot water indicator - flashes when hot water is running(?) # Icon Function 15 Floor sensor is connected, flashes when high limit is reached 16 Low Battery indicator 17 Gear - indicates user setting mode is active Group 1 or Group 2 indicator identifies Group number for Managing Thermostats. Group 1 or Group 2 indicator identifies Group number for Dependent Thermostats. 20 Temporary manual override HW Program mode(auto) indicator: Indicates program is running, Auto On or Auto Off. HW Mode indicator: Indicates turn on for 1 period a day, from Program 1 ON (start time) to Program 3 OFF (start time). 23 HW Mode indicator: Indicates Continuously On. 24 HW Mode indicator: Indicates Continuously Off. 25 HW Mode indicator: Indicates Boost +1hr override. 26 Active schedule block 27 Current day of the week (1=Monday, 2=Tuesday, etc.) 28 Key lock indicator: Indicates the pressed key is locked. 7.1

57 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Installer Parameter Setup Installers can set up the AS20WRF/BRF parameters using the SALUS Smart Home application if an SG888ZB Gateway is used and connected to the internet. Alternatively, the parameters can be entered directly on the AS20WRF/BRF Thermostat. The following procedure illustrates the offline setup. Changes made on the application or on the thermostat may take a few minutes to go into effect. Before starting set up procedures, press any key to light the display and prepare the Thermostat for input PM 1. To set up installation parameters on the AS20WRF/BRF Thermostat, simultaneously press & hold the, & buttons. 2. Press the up arrow for menu #49. Press confirm. 3. SEL Press confirm. 4. US E Press confirm. 5. Use & or confirm key to change the parameter id (d##). Use & to change the parameter value. 6. Pressing confirm advances to the next function. 7. Press confirm on function d19 to return to main screen. Descriptions, default values and value ranges for each thermostat function are listed on the following page. 7.2

58 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Functions & Parameters Function Default d00 Select Units 0 d01 Heating Control 0 d02 Temp. Offset 0 d03 Outdoor Sensor 0 d04 External Sensor 0 d05 Cooling Control 2 d06 Actuator Type 1 d07 Valve Protection 1 d08 Frost Setpoint 41ºF (5.0ºC) d09 Hour Format 1 Parameters Value 0 SI Metric Units - C 1 US Customary Units - F 0 Time Proportional & Integral (TPI) 1 ON/OFF 0.5 C (1.0 F) Increments 2 ON/OFF 1.0 C (2.0 F) increments -6ºF to +6ºF (-3.0ºC to +3.0ºC ) Description Room Temperature Offset (1.0 F/0.5 C increments) 0 Outdoor Sensor not connected to S1/S2 1 Outdoor Sensor or Ext. (d04) connected (10 kω) 3 Not Used 0 d03 = 1, Ext. air sensor active, Int. sensor inactive 1 d03 = 1, Ext. floor sensor active, Int. sensor active 1 ON/OFF 1.0 F (0.5 C) increments 2 ON/OFF 2.0 F (1.0 C ) increments 0 NO Normally Open 1 NC Normally Closed 0 ARV10RFM Valve Exercise Disable 1 ARV10RFM Valve Exercise Enable 41ºF to 63ºF (5.0ºC -to 17ºC ) Minimum room temperature for frost protection and holiday mode 0 12 Hour Time Format (eg. 5:00 pm) 1 24 Hour Time Format (eg. 17:00) d10 Not Applicable N/A N/A This function is not applicable d11 Daylight Savings 1 d12 Max. Heat Setpoint 95ºF (35ºC) d13 Max. Cool Setpoint 41ºF (5ºC) d14 d15 d16 Floor Sensor High Limit (heating) Floor Sensor Low Limit (heating) Floor Sensor Low Limit (cooling) 81 F (27 C) 50 F (10 C) 43 F (6 C) 0 Daylight Savings Time (DST) Off 1 Daylight Savings Time (DST) On 42ºF to 95ºF (17.5ºC to 35.0ºC) 41ºF to 104ºF (5.0ºC to 40.0ºC) 59ºF to 113ºF (15.0ºC to 45.0ºC) 43ºF to 104ºF (6.0ºC to 40.0ºC) 43ºF to 113ºF (6.0ºC to 45.0ºC) d17 Preset Programs d18 Heat/Cool Mode Selection 0 Maximum setpoint for heating mode Maximum setpoint for cooling mode Disable heat demand when floor temperature is above high limit. Increment: 1 F (0.5 C) Provide heat demand when floor temperature is below low limit. Increment: 1 F (0.5 C) Disable cooling demand when floor temperature is below low limit. Increment: 1 F (0.5 C) Select program. Once selected, the selected program will overwrite the present program. 0 Disable Heat/Cool selection 1 Enable Heat/Cool selection 7.3

59 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Setting the Time The time can be set directly on the AS20WRF/BRF User Interface or on the SALUS Smart Home application, provided a SG888ZB Gateway is used and connected to the internet. PM To set the time on the AS20WRF/BRF Thermostat, press & hold the confirm button. 3. P ress confirm to accept. The 12/24 selection is shown on the display. 5. Use the Up/Down Arrows & to set the flashing hour value. 2. Press the right arrow to enter the time format mode. 4. U se the right/left & arrows to select either 12 or 24 hours. Press confirm. 6. Press confirm and repeat to set the min. Then Press confirm again. 7. Use the Up/Down Arrows & to set the flashing year value and Press confirm. 8. U se the Up/Down Arrows & to set the flashing month value and Press confirm. 9. Use the Up/Down Arrows & to set the flashing day value and Press confirm. 7.4

60 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Setting the Temperature The AS20WRF/BRF Thermostat comes pre-programmed with a default setback schedule for weekdays and weekends. The instructions that follow the graphical representation of these schedules allow the installer to choose the target temperatures for each of these periods. Default Weekday Schedule Heating Mode Default Temp. Active Heating Mode Schedule Block Time (24hr clock) 00:00 07:00 09:00 17:00 23:00 Default Weekend Schedule Heating Mode Default Temp. Active Heating Mode Schedule Block Time (24hr clock) 00:00 08:00 09:00 17:00 23:00 Prior to pairing, the AS20WRF/BRF Thermostat must be set to the desired configuration. It can be configured as a programmable thermostat (default) or a digital thermostat. The default configuration,, will operate as either a standalone thermostat or the manager of a thermostat group. To operate the AS20 as a dependent in a group, it must be configured before pairing. 7.5

61 Section 7 Setting Device Parameters PM PM PM 1. Use the right/left & arrows to select the mode that corresponds to the intended temperature. For example, to set the high temperature, move box to the sun icon. 2. Use the Up/Down Arrows & to set the temperature for this period, then press confirm. 3. Repeat this process for the middle temperature and the low temperature. 4. When all temperatures are set, move the box to the letter A to run the current program. Note that a box remains around the icon for the current period. AS20WRF/BRF Thermostat Schedule Set Up Changing the default schedule for the AS20WRF/BRF Thermostat can be done directly from the User Interface or from the SALUS Smart Home mobile application, if an SG888ZB Gateway is used and connected to the internet. Graphical representations of the default schedules are on the previous page. Use the following graphs to plan schedule updates. Heating Mode Default Temp. Active Heating Mode Schedule Block F / C F / C F / C Time : : : : : 7.6

62 Section 7 Setting Device Parameters PM 1. Press & hold the confirm button to access the schedule program. 2. When the screen flashes with displayed, press confirm. 3. Use the right/left & arrows to select day(s) of the week to program. Press key to confirm selection The following grid shows the days of the week represented by the numbers. Options to choose 1-5, 6-7, or individual days provide maximum flexibility for setting up the schedule Mon Tues Wed Thur Fri Sat Sun

63 Section 7 Setting Device Parameters Use & to set the hour for the time that the first interval begins. Press to confirm selection. key 5. Use & to set the minutes for the time that the first interval begins. Press to confirm selection. key 6. Use & to choose the icon corresponding to the heating mode (hi-sun, med-cloud, low-moon). Press key to confirm selection. 7. After confirming the heating mode for the first interval, the next interval is displayed, follow the same procedures to set the start time for each remaining interval. To skip an interval, press the key until the appear for the hour and the minutes. The heating mode from the previous interval will be maintained until the next interval setting. 8. Set all desired intervals, leaving blanks for times when no change is desired

64 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Temporary Override PM PM PM 1. Use the & keys to set the temperature to the desired value. 2. Press confirm to confirm selection. The icon will show next to the current temperature until the next program interval. Pressing the > or < key will cancel the temporary program override returning to the temperature programmed for the current interval. AS20WRF/BRF Thermostat Permanent Temperature Hold PM PM 1. To enter permanent hold, use the & keys to choose the desired permanent heat mode: Low (moon), Med (clouds), High (sun). The target temperature will remain at the temperature designated for that heat mode until it is set back to automatic mode (A). 2. To switch back to the automatic program, use the & keys to move the selection box to automatic (A). The target temperature will again change as programmed. 7.9

65 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Parameter Setup with Internet Connection If the SG888ZB Gateway is used and is connected to the internet, the SALUS Smart Home application can be used to set up the parameters. Alternatively, the parameters can be entered directly on the AS20WRF/BRF Thermostat. In either case, changes may take several minutes to take effect To access the AS20WRF/BRF parameters from the SALUS Smart Home Application, follow the steps below. 1. Select the thermostat icon on the screen. 2. Press the thermostat name in the top left corner. 3. Press the settings gear icon to access parameters. 4. Scroll down to access parameters. 5. Enter desired parameters see table below for more info. 6. When parameters are set, scroll down and press, Save. 7.10

66 Section 7 Setting Device Parameters No Password Required The following are a list of functions and parameters that can be accessed without the password. To access more parameters the password must be entered. Instructions for entering the password to access more parameters follow. AS20WRF/BRF Thermostat SALUS Smart Home Application - Functions & Parameters Function Do you want to change the lock settings on your thermostat? Shut Off LCD Display Frost Setpoint Temperature Default No Turn On Hour Format 12:00 Fahrenheit or Celsius Parameters Value No Yes Turn On Turn Off Description No, Don t Lock it (allow occupants to make changes) Yes, Lock it (prevent occupants from making changes) Display is visible to occupants Display is not visible to occupants 41 F 41 F to 59 F Minimum room temperature for frost protection and holiday mode. OFF or Value 5 C 5 F to 15 F range shown depending on units selection in 1 F [0.5 C] increments Celsius 12:00 12 Hour Time Format (eg. 5:00 pm) 24:00 24 Hour Time Format (eg. 17:00) Celsius SI Metric Units - C Fahrenheit US Customary Units - F AS20WRF/BRF Thermostat Parameter Access Instructions with Internet Connection 1. Enter 49 in the password field and press, Ok. 2. Scroll down to find desired functions and change parameters as required. 3. Press Save when finished. 7.11

67 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat SALUS Smart Home Application - Advanced Functions & Parameters Function Default Parameters Value Description TPI Time Proportional & Integral (TPI) Heating Control ± 1.0 F [± 0.5 C] ± 0.50 F [± 0.25 C] ON/OFF Increment Resolution ± 1.0 F [± 0.5 C] ON/OFF Increment Resolution Room Temperature Offset 0 F [0 C] F to F C to C Thermostat reads Actual ± Offset Temperature Sensor Probe No Sensor Connected No Sensor Connected Sensor Probe Connected No sensor connected to S1/S2 on thermostat A sensor is connected to S1/S2 on thermostat Password Required Sensor Probe used as an air sensor or floor sensor Cooling Control Valve Protection Air Sensor ± 1.0 F [± 0.5 C] Enabled Air Sensor Floor Sensor Sensor for remote air temperature Sensor for radiant floor temperature ± 0.50 F [± 0.25 C] ON/OFF Increment Resolution ± 1.0 F [± 0.5 C] ON/OFF Increment Resolution Disabled Enabled ARV10RFM Protection Disabled ARV10RFM Protection Enabled Floor Sensor Limit for Cooling 45 F [7 C] 45 F to 113 F 7 C to 45 C Minimum floor temperature for cooling Floor Sensor High Limit Temperature 52 F [11 C] 52 F 113 F 11 C to 45 C Maximum floor temperature for heating Floor Sensor Low Limit Temperature 50 F[10 C] 45 F to 113 F 7 C to 45 C Minimum floor target temperature Do you allow to unlock from your thermostat side? Yes Yes No Controls permission to unlock the parameters menu from the thermostat user interface screen 7.12

68 Section 7 Setting Device Parameters AS20WRF/BRF Thermostat Schedule Setup with Internet Connection The following instructions are provided to set up the thermostat temperature schedule using the SALUS Smart Home Application. 1. Select the thermostat icon on the screen. 2. Press the thermostat name in the top left corner. 3. Press the settings gear icon to access parameters. 4. Scroll down to find the Schedule section. Choose the icon to edit. 5. Scroll down and choose Default schedule. 6. Review default schedule and edit as necessary. 7.13

69 Section 7 Setting Device Parameters 7. Edit temperatures and/or interval times to optimize the heating schedule. Press Update when done. 8. Repeat the process for Sa Su to create a weekend schedule. 9. Your AS20WRF/BRF Thermostat is now set up. However, you can make changes at any time. 7.14

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Thermostat INSTALLATION GUIDE Models: 1F86U-42WF, UP500W Version: October 2017 2017 Emerson Electric Co. All rights reserved. CONTENTS Installation guide Downloading the Sensi app 3 Creating

More information

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps Secure Internet Connection Computer Update ColorTouch to firmware version 2.0 or higher* Install the Wi-Fi Key and connect to a local router

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA Smart Smart Garage Garage Hub Hub Manual Manual For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA by Before You Start To reduce the risk of SEVERE INJURY to persons: DO NOT enable the MyQ Smart

More information

Hive Active Heating. Thermostat installation guide

Hive Active Heating. Thermostat installation guide Hive Active Heating Thermostat installation guide Status Hot Central water heating Status Hot Central water heating Here s what you ll need to install Hive Active Heating A working gas central heating

More information

PRO Installation. Thermostat Wi-Fi

PRO Installation. Thermostat Wi-Fi PRO Installation Thermostat Wi-Fi 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest connected

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA Smart Smart Garage Garage Hub Hub Manual Manual For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA by Before You Start To reduce the risk of SEVERE INJURY to persons: DO NOT enable the MyQ

More information

Lyric T6 & T6R Smart Thermostat

Lyric T6 & T6R Smart Thermostat Lyric T6 & T6R Smart Thermostat EN User Guide Lyric T6 Programmable Thermostat Lyric T6R Wireless Programmable Thermostat Lyric T6 & T6R Smart Thermostat Features Connects to the Internet so you can control

More information

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017 Models: 1F95U-42WF, ST75 Version: October 2017 Sensi TM Touch Wi-Fi Thermostat INSTALLATION GUIDE CONTENTS Installation guide Downloading the Sensi app 3 Creating a Sensi account 3 Installing the Sensi

More information

Manual & Technical Documentation V1.1

Manual & Technical Documentation V1.1 Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special

More information

Thermostat install guide

Thermostat install guide Thermostat install guide 74_Hive Thermostat Install Guide_97mmx97mm_v3.indd 1 23/11/2015 14:0 Install Guide For Hive Active Heating the thermostat, receiver and hub are installed together so heating and

More information

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat? Table of Contents Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat? 3-4 Power ON/OFF 26 Holiday Programming 27 Installation

More information

it500 Internet Thermostat INSTALLER MANUAL

it500 Internet Thermostat INSTALLER MANUAL it500 Internet Thermostat INSTALLER MANUAL . Product compliance & safety information These instructions are applicable to the SALUS Controls model stated on the front cover of this manual only, and must

More information

Control-R Wi-Fi Module

Control-R Wi-Fi Module ENGLISH Control-R Wi-Fi Module Installation Manual For Your Records If you have support questions, please call Customer Care and have your Control-R Wi-Fi module s AYLA ID and Water Heater Serial Number

More information

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual Model: RT310i Smartphone Controlled Thermostat Installation Manual Contents Product Compliance... 3 Safety Information... 3 Introduction... 4 Overview... 5 Box contents... 5 Features... 5 Connecting the

More information

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App Heating is great when you control it. USER MANUAL Wireless Programmable Room Thermostat Model No.: LS99111010 Scan for App Contents 1. Overview... 01 2. System Installation... 02 2.1 Install and Wiring

More information

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi Contents Introduction... Ideal Touch kit contents...

More information

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect

More information

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL Cloudwarm W i-fi Thermostat Comfort Anywhere Anytime MANUAL Content Content 1.Packing List 2.Compatibility 3.RF Coupling 4.App Setup And Wi-Fi Configuration 5.Room Thermostat (Transmitter) 6.Receiver 7.Technical

More information

Model: Available in: Sapphire Black and Glacier White. 1 Series

Model: Available in: Sapphire Black and Glacier White. 1 Series Model: Available in: Sapphire Black and Glacier White 1 Series Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure Mode Select Pairing the neohub

More information

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure 1 Model: 1 Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure 1 2 3-4 5-6 Mode Select Pairing the ProTouch iq Hub Pairing the ProTouch iq What

More information

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing. Table of Contents Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

RCS Residential Control Systems Inc.

RCS Residential Control Systems Inc. RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved. status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence

More information

Roth Touchline. German quality since Quick and easy user manual 1/10

Roth Touchline. German quality since Quick and easy user manual 1/10 Roth Touchline Quick and easy user manual German quality since 197 1/10 230 V Pump N N L L 230 V 230 V 2 V 2 V c/o in %H c/o out c/o in Trafo out /TB in N L eco 2V CH 1 CH 2 CH 3 CH 2V 2V 2V 2V 2V Touchline,

More information

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions Agenda Comfort Advantage System Configurations Installing ComfortNet ComfortNet Control Set up Dehumidification and Defrost Settings

More information

Daikin ENVi Thermostat installation overview

Daikin ENVi Thermostat installation overview Daikin ENVi Thermostat installation overview RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Presenter s Name Presenter s Title Daikin ENVi system overview (web based thermostat) Slide 2 Daikin ENVi System Overview

More information

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White Model: Available in: Sapphire Black and Glacier White 1 Series Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure Mode Select Pairing the neohub

More information

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control The easier, smarter heating system Multi-zone heating made easy User guide Setup and control Getting to know the Wiser system Wiser system Smart heating for your home Wiser is an advanced home heating

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi Quick start guide Connected wireless room thermostat Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi Introduction Welcome to the Ideal Touch quick start guide. This guide is designed

More information

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents. 1 Model: Available in : Sapphire Black and Glacier White Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation Procedure

More information

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model: Available in : Sapphire Black and Glacier White. 1 Series Model: Available in : Sapphire Black and Glacier White 1 Series Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation

More information

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series Model: Available in : Sapphire Black and Glacier White 2 Series Table of Contents Product Image 1 Locking/Unlocking the neostat 19 Table of Contents 2 Frost Protection 20 What is a Programmable Room Thermostat?

More information

Operation and Maintenance Manual OM 897-3

Operation and Maintenance Manual OM 897-3 Operation and Maintenance Manual OM 897-3 Wireless Temperature Control Use with factory or field installed Daikin WSHP wireless RCN Group: WSHP Document PN: 910203510 Date: March 2017 Part No. 668898001

More information

Phone: * Website: wiser.draytoncontrols.co.uk /DraytonHome

Phone: * Website: wiser.draytoncontrols.co.uk /DraytonHome Wiser Thermostat Kit 1 Wiser Thermostat Kit 2 Wiser Thermostat Kit 3 Wiser Multi-zone Kit 1 Wiser Multi-zone Kit 2 Phone: 0333 6000 622* Website: wiser.draytoncontrols.co.uk E-mail: customer.care@draytoncontrols.co.uk

More information

Model: RT310RF. Installation Manual

Model: RT310RF. Installation Manual Model: RT310RF Installation Manual Contents Product Compliance... 3 Safety Information... 3 Box Content... 3 Introduction... 4 Features... 5 Installation... 5 Button functions and keys... 7 Installer mode...

More information

Cent$ible Power Users Manual

Cent$ible Power Users Manual Users Manual Welcome to Cent$ible Power Thank you for your participation in the Cent$ible Power pilot program. Your involvement is greatly appreciated. As a program participant, you are on the cutting

More information

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS CONTROLS WI-FI THERMOSTAT PRODUCT SPECIFICATIONS icomfort Wi-Fi Flex Thermostat Bulletin No. 210725 December 2015 The icomfort Wi-Fi Flex Thermostat recognizes and connects conventional heating/cooling

More information

Mi HOME INSTALLATION AND INFORMATION GUIDE. Mi Home

Mi HOME INSTALLATION AND INFORMATION GUIDE.   Mi Home Mi HOME INSTALLATI AND INFORMATI GUIDE www.mihome4u.co.uk Mi Home Socket Relay Adapter Light Multiplug Mi Home Gateway Adapter Plus Open Sensor Heating Motion Sensor House Monitor Energy Monitor Essential

More information

Smart thermostat with Humidification/De-humidification control

Smart thermostat with Humidification/De-humidification control x Smart thermostat with Humidification/De-humidification control Enter/Confirm Scroll Right = Increase Left = Decrease Back/Cancel TABLE OF CONTENTS Everyday Use 1. Adjusting Temperature...3 2. Adjusting

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override LYRIC T6R-HW SMART THERMOSTAT PRODUCT SPECIFICATION SHEET The Lyric T6R-HW smart thermostat is designed to provide automatic time and temperature control of heating and stored Hot water systems in homes

More information

Model: RT510RF. Installation Manual

Model: RT510RF. Installation Manual Model: RT50RF Installation Manual Contents Product compliance... 3 Safety Information... 3 Box content... 3 Introduction... 3 Features... Installation... 5. RXRT50 Receiver... 5 Button Description for

More information

K1 SMARTHOME DIY KIT

K1 SMARTHOME DIY KIT K1 SMARTHOME DIY KIT EN DE FR NL ES USER MANUAL PT IT Contents 1. Things to Note before Getting Started 1 2. How the K1 System Works 2 3. Included in Your K1 Smart Home System 5 4. Device Overview 5 5.

More information

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0 Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0 Hello Anna. Before there were thermostats. Now there is Anna. Anna works for you and does what she is supposed to do:

More information

SMART THERMOSTAT WITH HOT WATER CONTROL

SMART THERMOSTAT WITH HOT WATER CONTROL T6R-HW SMART THERMOSTAT WITH HOT WATER CONTROL PRODUCT SPECIFICATION SHEET FEATURES Attractive, ultra-modern styling makes it ideal for any location in any type of home. Table stand thermostat to fit a

More information

Room Sensor [RBT-3C] Installation Instructions

Room Sensor [RBT-3C] Installation Instructions Room Sensor [RBT-3C] Installation Instructions Room Sensor to replace existing wired room thermostat. Provides programmer / time clock functionality. Requires Network OWL to operate. IN THE BOX: Room Sensor

More information

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS Below you will find information about your installation and what you can expect to happen next. There are also some important steps to follow to ensure

More information

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional: status ALC-PACK3 WiFi Alarm System with HD WiFi Camera User Manual Your Watchguard Wireless Security professional: www.activeonline.com.au 1300 816 742 Foreword Congratulations on your purchase of the

More information

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control The easier, smarter heating system Multi-zone heating made easy User guide Setup and control Getting to know the Wiser system Wiser system Smart heating for your home Wiser is designed to be simple to

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

status AW1 Plus WiFi Alarm System User Manual

status AW1 Plus WiFi Alarm System User Manual status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise

More information

PRT-TS WiFi PRT-TS WiFi

PRT-TS WiFi PRT-TS WiFi Model: PRT-TS WiFi Model: PRT-TS WiFi 1 Model: PRT-TS WiFi Table Of Contents Product Image 1 Frost Protection 16 Table of Contents 2 Heating ON/OFF 16 What is a Programmable Room Thermostat? Installation

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training Sensi Wi-Fi Thermostat 1F87U-42WF Installation Training Sensi Wi-Fi Thermostat Key Features Universal application (singlestage, multi-stage and heat pump) Compatible with popular smart home platforms Contractor-On-Call

More information

Model: Slimline-RF. 1 Slimline Series

Model: Slimline-RF. 1 Slimline Series Model: Slimline-RF Model: Slimline-RF 1 Slimline Series Table of Contents Product Image 1 Holiday Programming 22 Table of Contents What is a Programmable Room Thermostat? 2 3-4 Setting the Hot Water Switching

More information

Underfloor Catalogue Heating products that define the market

Underfloor Catalogue Heating products that define the market YEAR 5 WARRANTY Underfloor Catalogue Heating products that define the market By Underfloor Heating Control We provide a range of room temperature controls (thermostats) to optimize the operating efficiency

More information

Installation Instructions

Installation Instructions TSTPHA01, Côr 5 TSTWHA01 Côr 5C TSTPRH01, Côr 7 TSTWRH01 Côr 7C Residential Thermostats Installation Instructions Côrr7 Non - Wi - Fi, Côrr7C Wi -Fi Series (Humidity Control) Côrr5 Non - Wi - Fi, Côrr5C

More information

How to install your Nest Protect

How to install your Nest Protect How to install your Nest Protect You can easily install your Nest Protect in just a few minutes. Follow the steps in this article to learn how. To set up and install your Nest Protect, you will need: A

More information

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT CONTENTS Installation Instructions for Heating & Air Conditioning 1F79 n-programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

lightwaverf Boiler Switch Model No. JSJSLW920 Instruction Manual Professional Series

lightwaverf Boiler Switch Model No. JSJSLW920 Instruction Manual Professional Series lightwaverf Boiler Switch Model No. JSJSLW920 Instruction Manual Professional Series www.lightwaverf.com Get started How do I get started? To install the Boiler switch, please follow these instructions.

More information

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH) Installation guide Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Ideal Touch

More information

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF Operating Instructions Model: PRT-TS WiFi RF 01/13 Version 1 Ref: PRT-TSWIFI RF Contents Page Setting up your WiFi Thermostat 2-6 Remote Connection Setup 6-8 Pairing with the Receiver 8-12 Display Symbols

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Getting started with

Getting started with Getting started with The Heating Hub Unit sits at the heart of your Polypipe system and makes your home cloud connected for both monitoring and control. IN THE BOX: Heating Hub Unit Plug top mains power

More information

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Personal Reference Guide Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Welcome to your new Brighten ithermostat

More information

IntelliSync Thermostat / Mobile App Frequently Asked Questions

IntelliSync Thermostat / Mobile App Frequently Asked Questions IntelliSync Thermostat / Mobile App Frequently Asked Questions This FAQ page addresses the most common questions on Deriva IntelliSync. Why bother setting a heating and cooling schedule? What is ENERGY

More information

Installation Instructions

Installation Instructions TSTPHA01, Côr 5 TSTWHA01 Côr 5C TSTPRH01, Côr 7 TSTWRH01 Côr 7C Residential Thermostats Installation Instructions Côr 7 Non Wi Fi, Côr 7C Wi Fi Series (Humidity Control) Côr 5 Non Wi Fi, Côr 5C Wi Fi (No

More information

GETTING STARTED WITH SMART THERMOSTAT

GETTING STARTED WITH SMART THERMOSTAT GETTING STARTED WITH SMART THERMOSTAT This document is the property of Webee L.L.C.. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for any

More information

APPLIANCES CONTROL SECURITY HEATING

APPLIANCES CONTROL SECURITY HEATING APPLIANCES SECURITY HEATING Make the most of life by controlling and monitoring your home from anywhere via your Smartphone, Tablet or PC. Giving comfort and convenience at an affordable price. CONTROL

More information

C-Stat 17-ZW User Instructions

C-Stat 17-ZW User Instructions C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide Why Vaillant? Because there s smart and then there s vsmart Vaillant vsmart The USER Guide Allow me to introduce myself... What s in the box? Saving energy has never been so easy. Designed to work harmoniously

More information

RedLINK Wireless Comfort Systems. RedLINK Connects.

RedLINK Wireless Comfort Systems. RedLINK Connects. RedLINK Wireless Comfort Systems RedLINK Connects. TM THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS wireless TM Your Customers Are Connected. Wireless.

More information

Salusfin Smart heating control: Installation Guide

Salusfin Smart heating control: Installation Guide Salusfin Smart heating control: Installation Guide Detailed instruction can be found on our web site on all installation phases: FAQ s, Technical user guides and manufacturer s manuals. Video links can

More information

OWNER OPERATION MANUAL FOR USER 2.0

OWNER OPERATION MANUAL FOR USER 2.0 OWNER OPERATION MANUAL FOR USER.0 Contents kumo cloud... Quick Setup... Get Started... Download the App... Create an Account... Control... Whole or Individual Zone... Temperature... Cool, Heat and Other

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo neo Model: Available in : Sapphire Black and Glacier White 1 Wavin neo Table of Contents Product Image 1 Optional Features 19-22 Table of Contents 2 Re-calibrating the Thermostat 23 What is a Programmable

More information

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING Emerson Inspire 1HDEZ-1521 Installation Instructions Thermostat/Interface Equipment Control TROUBLESHOOTING FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL

More information

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk DRAWING DETAILS PART NUMBER 42011077-103 ISS R1 ECO AND DATE 0024168 08/06 ARTWORK DESCRIPTION CM921 USER GUIDE BOOKLET (UK - English) DRAWN MKTING MF BM DATE 08/06 BOOKLET DETAILS SPECIFICATION COVER

More information

TempSmart TS-100. Temp & Humidity Data Logger. User Guide

TempSmart TS-100. Temp & Humidity Data Logger. User Guide TempSmart TS-100 Temp & Humidity Data Logger User Guide 1 Introduction to the TempSmart TS-100 Table of Contents (by page number) 3 Overview 4 First Connection 6 Settings 6 Alerts 7 Main App Screen 7 Data

More information

Installation Guide for. Energate Thermostats. Pioneer release 2.3 and HōlHōm/Foundation release 3.5

Installation Guide for. Energate Thermostats. Pioneer release 2.3 and HōlHōm/Foundation release 3.5 Installation Guide for Energate Thermostats Pioneer release 2.3 and HōlHōm/Foundation release 3.5 Table of Contents 1 Introduction... 4 1.1 Operating the HōlHōm/Foundation Thermostat... 5 1.2 Operating

More information

CentaurPlus ZW and HRT4-ZW

CentaurPlus ZW and HRT4-ZW CentaurPlus ZW and HRT4-ZW Installation Instructions The Horstmann CentaurPlus ZW combined wireless room stat and timeswitch allows a combi boiler system to have a room thermostat added without the need

More information

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions DESCRIPTION The RC-122BZ is a precision digital thermostat designed for 24 VAC two-stage heating and cooling

More information

MODEL DZSP/ SZSP-1440 AIRCELL

MODEL DZSP/ SZSP-1440 AIRCELL ACCM2-0513 55W30-AC0118 MODEL DZSP/ SZSP-1440 AIRCELL CONTROL MANUAL Control Adjustment and Operation Instructions CONTROL OVERVIEW/STANDARD FEATURES INITIALIZATION Section 1: Firmware blink code... 2

More information

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE Climate Cŏntrol Zoning System Installation Guide Uponor Climate Cŏntrol Zoning System Installation Guide Published by

More information

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to

More information

Installation manual Anna. In combination with the Smile T. Manual PW version 2.0

Installation manual Anna. In combination with the Smile T. Manual PW version 2.0 Installation manual Anna. In combination with the Smile T. Manual PW version 2.0 Hello Anna. Before there were thermostats. Now there is Anna. Anna works for you and does what she is supposed to do: create

More information

K1 SMARTHOME DIY KIT

K1 SMARTHOME DIY KIT K1 SMARTHOME DIY KIT EN DE FR NL ES QUICK GUIDE PT IT Contents 1. Things to Note before Getting Started 3 1.1 High-speed WiFi Internet Connection 3 1.2 SSID and Password 4 1.3 Operating System Requirements

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

VT8300 Series Installation Guide 24 Vac Low Voltage

VT8300 Series Installation Guide 24 Vac Low Voltage Vac Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Configurable BI/UI Universal Inputs Overview Setup Screen Display Terminal Identification & Function Terminal

More information

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer Installation and interface must be performed by a qualified controls technician. IMPORTANT: THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION, INTERFACE AND CONFIGURATION OF THIS EQUIPMENT. READ

More information

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options Spotlight Cam Mount Smart Security at Every Corner of Your Home Your new Spotlight Cam lets you extend the Ring of Security around your entire property. Now, you ll always be the first to know when someone

More information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING MODEL Premier Series 3000 USER MANUAL Non-Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information