MyFAST 16.0 Plus. Layout. Influent See note 4
|
|
- Emma McBride
- 5 years ago
- Views:
Transcription
1 NOTES: 1. The air supply line into the FST unit must be secured so as to prevent damage from pipe vibration. 2. The units are supplied with 3" semi-flexible airline connections with stainless steel MPT fittings. 3. Each blower will require 4" steel pipe to connect to the distributed airlift system. 4. Influent pipe shall be positioned to maximize preaeration. Influent shall come from a prescreening device selected based on the site conditions and characteristics of the influent. Influent See note 4 () 161 SaniTEE Screens Sludge Holding Overflow Sludge Collection Treatment Zone FST Blowers Collection Manifold LIXOR 4.0 XD Preaeration Zone Sludge Holding Zone MyFST 16.0 Plus (32) 161 SaniTEE Screens Blowers and Blower Housings (2)Central Control Panel Biosolids collection piping (16) MyFST Segments (4)LIXOR 4.0 XD OPTIONL MyFST 16.0 BMS (Biosolids Management System) (2)Dual Sludge Pumps (2)Decant Pumps (2)LIXOR 4.0 (2) Jib Cranes THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE Sludge Pump ccess Sludge release to dewatering station SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 MyFST 16.0 Plus Layout REV. INI-02-M 1 OF 6
2 Influent Emergency overflow from Biosolids Storage Zone 16" SaniTEE Screen placement Biosolids Pump Pit 567 MIN 223 MIN 1152± ±10.00 Treatment Zone 0,000 Gallon MIN [303 m3 MIN] 79 MIN 994±13 31 MIN 391± Preaeration Zone 40,000 Gallon MIN [151m3 MIN] 76 MIN 30 MIN 122 MIN 4 MIN 1015±25 400± Biosolids release to Dewatering Station MIN 36 MIN Sludge Holding Zone 16,00 Gallon MIN [63 m3 MIN] MIN 23 MIN Freeboard 109 MIN 43 MIN 79 MIN 31 MIN 264 MIN 104 MIN 246 MIN 97 MIN 229 MX 90 MX Biosolids Water Level 264 MIN 246 MIN 104 MIN 97 MIN PVC pipe opening 10 PVC Pipe MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 Tank Details REV. INI-01-Q 2 OF 6
3 10 PVC Components to attach to sludge pump pit provided by others 160± ± PVC TEE PVC TEE 155±1.3 61±.5 PVC Pipe 160±1 6 PVC Pipe 160±1 6 PVC Eow 6 PVC TEE Notes: 1. Biosolids Collection Supplied by Bio-Microbics 2. Secure Biosolids Collection grid every 36" [90 cm] MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 Biosolid Collection REV. INI-01-I 3 OF 6
4 OPTIONL DIGEST ZONE See note 5. Jib crane Biosolids pump cable Decanting Pump See note 7 Electrical conduit to Bio-Microbics control panel provided by others Return to Treatment Zone " MIN air supply line utilizing galvanized or stainless steel piping from the blower housing to the treatment tank provided by others. 35 Concrete base provided by others 2 screws per side included See Note MIN 12 MIN Minimum leg extension assembly See Note 2 & 3 See Note 5 Biosolids Pump See note 6 LIXOR 4.0 Notes: 1. Secure leg extension to the FST unit by placing two screws on each side of the leg extension (4 screws per foot are included). 2. To obtain the desired height of leg cut 4" [10] schd. 40 PVC pipe (not included). Minimum pipe length of 11 1/" [2.26]; For heights greater then 1" [45.7] use schd. 0 PVC pipe (not included). Consult factory for extending leg beyond 36"[91]. 3. nchor the leg extensions to the tank with non-corrosive hardware (not included) at the provided mounting points. 4. Tank, anchors, piping conduit, blower, housing pad and vents are provided by others. 5. LIXORs must be spaced in Biosolids Storage Zone for maximum mixing and aeration. Consult Bio-Microbics. 6. Sludge pump discharge piping must create at least 22' [6.7m] of TDH at 60 Hz and ' [2.4m] of TDH at 50 Hz. 7. Decant pump discharge piping must create at least 22' [6.7m] of TDH at 60 Hz and ' [2.4m] of TDH at 50 Hz. MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 Details REV. INI-05-K 4 OF 6
5 Specifications for MyFST 16.0 Plus Wastewater Treatment System 1. GENERL The contractor shall furnish and install (1) MyFST 16.0 Plus treatment system as manufactured by Bio-Microbics, Inc. The treatment system shall be complete with all equipment as shown on the drawings and specified herein. The principal items of equipment shall include sixteen (16) FST interconnecting inserts with leg attachments, biosolids collection manifold, sixteen (16) SaniTEE screens, four (4)blower assemblies, and control panel. The MyFST 16.0 Plus unit shall be situated within a gallon (606 m3) minimum tank, as shown on the plans. Settling tank(s) equaling ½ to 1 x daily flow must be used prior to MyFST. Tank(s) must conform to local, state, and all other applicable codes. The contractor shall provide coordination between the MyFST system and tank designer (supplier) with regard to fabrication of the tank, interconnecting piping, wiring, and similar items, installation of the MyFST unit and delivery to the job site. The optional Biosolids Management System shall include a biosolids wasting pump and biosolids decant pump with jib crane, two (2)LIXOR 4.0s with blower assemblies. ll tanks supplied by others. 2. OPERTING CONDITIONS The MyFST 16.0 PLUS treatment system shall be capable of treating the wastewater produced by typical family activities (bath, laundry, kitchen, etc.) ranging from four hundred (400)to two thousand four hundred (2 400) persons and not to exceed US Gallons per day(606 m3/d). 3. MEDI The MyFST media shall be manufactured of rigid PVC, polyethylene, or polypropylene and it shall be supported by the polyethylene insert. The media shall be fixed in position and contain no moving or wearing parts and shall not corrode. The media shall be designed and installed to ensure that sloughed solids descend through the media to the bottom of the tank. 4. BIOSOLIDS COLLECTION MNIFOLD biosolids collection manifold will be provided which will be located below the MyFST The biosolids collection manifold will consist of (6) six PVC lateral pipes that are equally spaced under the MyFST 16.0 with orifices specifically designed to remove biosolids from the MyFST zone. The 6 laterals will be connected into a PVC pipe header that will provide a single 10 inch discharge into the tank s Biosolids Pump Pit. 5. BLOWER The MyFST 16.0 PLUS unit shall come equipped with four blowers capable of delivering to 2 00 CFM [ m3/hr]. The blower assembly shall include an inlet filter with metal filter element. 6. REMOTE MOUNTED BLOWER The blowers shall be mounted outside the tank adjacent to the MyFST zone on a contractor supplied concrete base. The blower elevation must be higher than the water level in the tank and above any normal flood level. two-piece, rectangular housing shall be provided with tamper-proof screws. The 4 inch (100 mm) steel discharge air line and connections from the blower to the two (2) MyFST 4 inch (50 mm) air headers which shall be provided and installed by the contractor. 7. ELECTRICL/CENTRL CONTROL PNEL ll wiring must conform to code and provide the specified power to the blowers. Input power on 60 Hz electrical system is 230/415 VC, three phase, 372/193. mps. Input power on 50 Hz electrical systems 220/30VC, three phase, 353.4/216.6 mps. ll conduit and wiring shall be supplied by contractor. The control panel shall utilize a motor starter, overload, and be housed in a NEM 4 X enclosure. The control panel shall consist of a visual and audible alarm to indicate loss of power to the blower. manual silence switch is included.. OPTIONL BIOSOLIDS MNGEMENT SYSTEM OPTIONL BIOSOLIDS WSTING PUMP biosolids wasting pumps are located in the biosolids pump pit will be included with the optional biosolids management system. These pumps shall be capable of pumping 00 to 1200 gpm [3030 to 4540 Lpm] at 20 feet [6m] total dynamic head to the biosolids storage zone. The biosolids wasting pump will require a power supply from the panel to the pump. field adjustable event timer will control the duration of the wasting time and the frequency of wasting on an event timer. The contractor is responsible for supplying power to the pump. THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE NME DTE DRWN 3/27/2009 PF 5/25/2010 SIZE DRWING NUMBER MyFST 16.0 Plus Specifications 1 of 2 5 OF 6 REVISED 5/25/2010 REV.
6 Specifications for MyFST 16.0 Plus Wastewater Treatment System. OPTIONL BIOSOLIDS MNGEMENT SYSTEM CONTINUED. OPTIONL DECNT PUMP ND JIB CRNE decant pump will be included to pump the supernatant from the biosolids storage ZONE into the MyFST aeration zone. The submersible decant pump shall be capable of pumping 200 to 250 gpm[ Lpm] at 20 feet [6m] of total dynamic head to the MyFST aeration zone. The contractor is responsible for supplying power to the pump. The decant pump will be controlled by a manual start/stop controller. Two (2) jib cranes will be provided for decant pump intake height adjustments to remove the supernatant from the biosolids storage zone. The jib crane will be designed to handle a lifting capacity of 500 Lbs. and a lifting range of 160 inches [305cm]. 9. GENERL INSTLLTION INSTRUCTIONS ll work must be done in accordance with local codes and regulations. Installation of the MyFST 16.0 Plus shall be done in accordance with the written instructions provided by the manufacturer. n operation and maintenance manual shall be furnished which will include a description of system installation, operation, and maintenance procedures. Each FST interconnecting insert weighs approximately 1300 pounds [590kg]. Four holes for lifting each FST interconnecting insert are supplied. Spreader bars are to be used in lifting the inserts. Place spreader bars between lifting holes. For details refer to the Installation Manual. 10. FLOW & PIPE SIZING The MyFST 16.0 Plus has eight () six (6) inch discharge ports. Each of the six (6) discharge ports are provided with a standard six (6) inch effluent gasket. The maximum free or unrestricted flow with the two (2) each six (6) inch effluent pipes is 250 U.S. GPM (945 LPM) with a 2.0 design safety factor. MyFST systems have been successfully designed, tested and certified receiving gravity, demand-based influent flow. When influent flow is controlled by pump or other means to help with highly variable flow conditions, then multiple dosing events should be used to maximize performance. 11. WRRNTY Bio-Microbics, Inc. warrants all new MyFST Plus models (MyFST Plus 4.0,.0, and 16.0) against defects in materials and workmanship for a period of one year after installation or eighteen (1 months) from the date of shipment whichever occurs first, subject to the following terms and conditions: During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated and maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge. Defective parts must be returned by owner to Bio-Microbics, Inc. s factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty and regular maintenance items such as filters or bus shall be borne by the owner. This warranty does not cover general system misuse, aerator components which have been damaged by flooding or any components that have been disassembled by unauthorized persons, improperly installed or damaged due to altered or improper wiring or overload protection. This warranty applies only to the treatment plant and does not include any of the structure wiring, plumbing, drainage, septic tank or disposal system. Bio-Microbics, Inc. is reserves the right to revise, change or modify the construction and/or design of the MyFST system, or any component part or parts thereof, without incurring any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, material, or workmanship, or delays in delivery, replacements or repairs. THIS WRRNTY IS IN LIEU OF LL OTHER WRRNTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICLLY DISCLIMS NY IMPLIED WRRNTY OF MERCHNTBILITY OR FITNESS FOR PRTICULR PURPOSE. NO REPRESENTTIVE OR PERSON IS UTHORIZED TO GIVE NY OTHER WRRNTY OR TO SSUME FOR BIO-MICROBICS, INC., NY OTHER LIBILITY IN CONNECTION WITH THE SLE OF ITS PRODUCTS. Contact your local distributor for parts and service. MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE NME DTE DRWN 3/27/2009 PF 5/25/2010 SIZE DRWING NUMBER Specifications 2 of 2 REVISED 5/25/2010 REV. 6 OF 6
MyFAST 8.0 Plus. Layout
Influent from a prescreening device 1618 SaniTEE Screens emergency overlfow from Sludge Holding Zone Sludge Collection 1015 MIN 400 MIN Lateral Brace by others 246.4 MIN 97 MIN NOTES: 1. The air supply
More informationMyFAST 6.0 BASIC. MyFAST 6.0. OPTIONAL: MyTEE Screen AMS & BMS. Biosolids Port by others
Influent SaniTEE 1618 Screens MyFST 6.0 BSIC Treatment Zone Lateral braces Effluent Collection Pipe by others FST Blowers Product Description & Layout MyFST 6.0 BSIC Designed to treat approximately 60,000GPD
More informationLateral braces. Effluent Collection Pipe. by others. FAST Blowers. Airlines. 8" min. 20cm min. DETAIL A SCALE 1 : 25. Biosolids Port.
Influent MyFST 8.0 BSIC SaniTEE 1618 Screens Settling Zone Treatment Zone Lateral braces Effluent Collection Pipe by others FST Blowers irlines Product Description & Layout MyFST 8.0 BSIC Designed to treat
More informationSaniTEE 1618 Screens. Biosolids Port by others BIO-MICROBICS 2014 DRAWN CTC 3/27/2009. MyFAST 4.0 BASIC Product Description & Layout
MyFST 4.0 BSIC Product Description & Layout Influent SaniTEE 1618 Screens Treatment Zone Lateral braces Effluent Collection Pipe by others MyFST 4.0 BSIC Designed to treat approximately 40,000 GPD (150
More informationControl Panel. 183 MAX 72 MAX Height of Effluent Line. Maximum Water Level 124 MAX 49 MAX
Gallon MIN SaniTEE 818-B Blower Housing 3700-4500 Gallons [14000-17000 L] Control Panel 1. Blower piping to BioBarrier MBR may not exceed 40 FT [12 m] total length and use 4 elbows maximum per train. For
More informationInstallation, Operation & Service Manual
Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and
More informationVSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.
Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From
More informationTHARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE
THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, 5175 8R35, 10R60, 13R75 FEATURES PREPARATIONS INSTALLATION OPERATION MAINTENANCE SAFETY SAFETY NOTICE IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS Hardware Procedure: AERCO Buffer Tank Installation and Maintenance Applies to: Any applicable water heater/boiler piping system arrangement. Description of Document: This provides
More informationOWNER S MANUAL ONSITE WASTEWATER TREATMENT SYSTEM MODEL NUMBER FTB 0.5 FTB 0.6 FTB 0.75 FTB 1.0 FTB 1.5
OWNER S MANUAL ONSITE WASTEWATER TREATMENT SYSTEM MODEL NUMBER FTB 0.5 FTB 0.6 FTB 0.75 FTB 1.0 FTB 1.5 1501 Commerce Center Drive Franklin OH 45005 Tel: 513-746-2727 Fax: 513-746-1446 www.consolidatedtreatment.com
More informationPLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual
Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it should
More informationQuest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest Dry Quest 110 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate
More informationFreestanding Acrylic Bathing Installation Instructions
Freestanding crylic Bathing Installation Instructions RED THESE INSTRUCTIONS COMPLETELY BEFORE INSTLLING THE PRODUCT. FOR PRODUCT OR INSTLLTION QUESTIONS PLESE CLL CUSTOMER SERVICE T -800-22-3379. YOU
More informationModel CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950
Technical Services 00--9 +-0--0 www.tyco-fire.com Model CV-FR Riser Check Valves to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Riser Check Valve is a compact and rugged swingtype unit
More informationPLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual
Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control PLL Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationINSTRUCTION MANUAL HS-229G
INSTRUCTION MANUAL HS-229G 510977 STEP 1 - Where to Install the Thermostatic Steam Trap Determine where to install the thermostatic steam trap based on the following information. a. The trap should be
More informationCarbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)
Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay 905-0005-01 (100/25 PPM) 905-0005-02 (200/35 PPM) 1. INTRODUCTION Your COSTAR VC carbon monoxide detecting ventilation
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationCarbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay
Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay Part No. 905-0000-09 Replacement Sensor Module is Part Number 905-0001-09 1. INTRODUCTION Your COSTAR 24VC-e carbon
More informationCELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler
CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and
More informationTYPE POS Oil Shield Sump Pump
Type POS Oil Shield Provides protection for the environment by preventing oil products from entering sewer systems, environmentally Sensitive River and waterways, while protecting equipment and areas from
More informationINFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:
INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT
More informationOwner s Manual Hydro-X Vacuum Pac
4201 Lien Rd Madison, WI 53704 Owner s Manual Hydro-X Vacuum Pac Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Hydro-X Vacuum Pac outperforms the competition
More informationBEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER
RBDS-1 RBD SERIES CERAMIC HEATERS NATURAL GAS (Check One) PROPANE GAS EQUIPMENT USED: ACCESSORIES: Chain Mounting Kit: Thermostat: Gas Pressure Regulator: Parabolic Extension: Gas Shut-Off Valve: Reverb
More informationINDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION
INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION Contents MODEL WS... 2 STANDARD FEATURES... 2 TECHNICAL DATA... 3 DIMENSIONS... 3 ENGINEERING DATA...
More informationModel A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.
Technical Services: Tel: (00) 31-9312 / Fax: (00) 91-5500 Customer Service/Sales: Tel: (1) 50-5000 / (00) 55-523 Fax: (1) 50-5010 / (00) -1295 Model A Pipe Line Strainer 3,,, & 10 Inch (DN0, DN100,, DN200
More informationINGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS
INGERSOLLrAND AIR COMPRESSORS HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS CAUTION: For HMD Models 84 Through 385 ONLY 1. Remove Dryer Chambers And Protective
More informationFEATURES. Other Fed-Flush Arrangements
Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags
More informationQuest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest Dry 150 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,
More informationSentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12
PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting
More informationINSTALLATION AND OPERATION INSTRUCTIONS
Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RFPA21A CONSTRUCTION HEATER FLOOR MODEL SAVE FOR FUTURE REFERENCE Space-Ray Division, Gas Fired Products, Inc. P.O. Box 36485, Charlotte, NC 28236
More informationCAR-MON DUST COLLECTORS SERIES 207, 2410, 3015
INSTALLATION-OPERATION-MAINTENANCE CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 TEFC 3 phase motor Outlet duct Fan wheel housing Inlet duct connection After filter transition Optional after filter unit
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Models S0000-AL1
More informationOperation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners
Operation Manual PortaPac 5-, 8 and 10-ton Portable Air Conditioners A AirPac, Incorporated AirPac Technology Park 888 Shenandoah Shores Road Front Royal, Virginia 22630 U.S.A. Toll Free 888-324-7722 Web:
More informationOwners Instruction Manual
Owners Instruction Manual Ultra Clear WASTE WATER TREATMENT SYSTEMS Domestic Single Tank Systems Contents Page Foreword 1 Description & Function Primary Treatment Aerobic Treatment Sludge Return Surge
More informationXaact Spot. Xaact Hot Spot
Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............
More informationCWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual
CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference
More informationUser Guide. for the Beacon ProActTM 200 System
TM User Guide for the Beacon ProActTM 200 System BEACON recommends that this product, like all sump pumprelated products, be installed by or under the supervision of a professional plumbing contractor.
More informationC&M REAR FEED Long-stroke Vertical Down-stroke Baler for Baling Multi-Materials
June 21, 2011 Used C&M 3050V-7-15 C&M REAR FEED Long-stroke Vertical Down-stroke Baler for Baling Multi-Materials MATERIAL TO BE BALED: Used Clothing & Other Materials BALER DESCRIPTION: USED C&M MODEL
More informationDuct Mount. Installation Instructions
Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be
More informationRetrofit Instructions for Tower Dryer Moisture Sampler Blower Kit
Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Installation Manual PNEG-1982 Date: 03-26-15 PNEG-1982 2 PNEG-1982 Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Table
More informationSentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.
Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...
More informationDUST FREE CARBON Whole House Air Purifier
DUST FREE CARBON Whole House Air Purifier Installation & Operation Manual This manual covers the following model: DF CARBON 14" - #13052 GENERAL This device is designed to be installed into an existing
More informationFOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:
A DIVISION OF FOSTORIA INDUSTRIES, INC. 1200 North Main Street Fostoria, OH 44830-1911 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com VHC-32 Variable Heat Controller for 222 MUL-T-MOUNT
More informationMH70230AS MH70236AS MH70248AS
MODEL #. MH70230AS MH70236AS MH70248AS Installation, Use and Care Guide READ AND SAVE THESE INSTRUCTIONS 2014.NOV SAFETY NOTICE... 2-3 LIST OF MATERIALS... 4 INSTALLATION Ducting Calculation Sheet...
More informationQuest Power Electric Heat EHS 31 Pro
Quest DRY Power 150 Electric Heat EHS 31 Pro Read and Save These Instructions The Power Electric Heat EHS 31 Pro portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed
More informationDISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG
! GMB-PS WARNING Disconnect from power source before removal of any panel or replacement of any component! FUNNEL CONTENTS ARE HOT CAUTION DISCARD DECANTER IF:. CRACKED. SCRATCHED. BOILED DRY. HEATED WHEN
More informationOwner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08
Owner s Guide 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 2-4 MAINTENANCE... 11... Oven or broiler door... 11 CLOCK AND TIMER... 5 Oven bottom...
More informationOwner s Manual Phoenix FireBird
4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix FireBird Installation, Operation and Service Instructions Important Instructions Read and Save These Instructions The FireBird portable, heavy duty
More informationRP, GP, XP Pro Series Installation Instructions
RP, GP, XP Pro Series Installation Instructions IN095 Rev B 0718 3 Saber Way, Ward Hill, MA 01835 radonaway.com 1 Fan Installation & Operating Instructions RP, GP, XP Series Fans Please Read and Save These
More informationOWNER S MANUAL FOR USE WITH BIO-MICROBICS, INC. FAST WASTEWATER TREATMENT SYSTEMS
OWNER S MANUAL FOR USE WITH BIO-MICROBICS, INC. FAST WASTEWATER TREATMENT SYSTEMS IMPORTANT: We urge you to fully read this manual. The contents are important to your safety and the operation of the Bio-Microbics,
More informationDetection System Model 3500 Series
Detection System Model 3500 Series Architect/Contractor Information Package 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 Copyright 2001-2006 3M. All rights reserved.
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationMultiple Boilers Electro TS Series Application EB-C-STG5
Multiple Boilers Electro TS Series Application EB-C-STG5 Drawings: BC025 BX404 BH504 XX017 Information All Electro-Boilers, except Mini-Boiler, have the same control board (EB5623**). The plug-in control
More informationControllers. Instruction Manual WARNING
Controllers Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of
More informationDISCARD DECANTER IF: FUNNEL CONTENTS ARE HOT FAILURE TO COMPLY RISKS INJURY
! BUNN GMB-PS WARNING Disconnect from power source before removal of any panel or replacement of any component! FUNNEL CONTENTS ARE HOT CAUTION DISCARD DECANTER IF:. CRACKED. SCRATCHED. BOILED DRY. HEATED
More informationAPPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS
APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS SCU-30 SWU-30 Napps Technology Corporation P.O. Box 3066 Longview, TX 75606-3066 Phone: (903) 758-2900 FAX:
More informationSentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.
Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3
More informationDashley Outdoor Fire Table
Dashley Outdoor Fire Table MODEL N0. 085-557-8 L-FT047PST-F ASSEMBLY INSTRUCTIONS Toll-free 888 670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this
More informationHS Series Installation & Operating Instructions RadonAway
The World s Leading Radon Fan Manufacturer HS Series Installation & Operating Instructions RadonAway 3 Saber Way Ward Hill, MA 01835 www.radonaway.com P/N IN007-REV K 10/15 RadonAway Ward Hill, MA. HS
More informationInstruction Manual WARNING
Controllers Instruction Manual WARNING THIS MANAUL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of
More informationBX Series. Installation, Operation, Maintenance Instructions & Spare Parts
ISO 9001 BX Series Installation, Operation, Maintenance Instructions & Spare Parts WARNING WARNING. The BX convection heater is a heavy duty baseboard designed for use in industrial environments and is
More informationCorrosion Dry Air Pak
Corrosion Dry Air Pak ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR MIC REDUCTION IN DRY PIPE SPRINKLER SYSTEMS Installation, Operation, & Maintenance Manual MODELS CDP500, CDP1000, & CDP2000 MFG#: 5403584
More informationMP-MBA-45T-1/60T-1 / 75T-1
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-45T-1/60T-1 / 75T-1 with the 268/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description
More informationINSTALLATION, OPERATION AND MAINTENANCE
INLINE HEATER INSTALLATION, OPERATION AND MAINTENANCE MODELS: ILS SERIES 1.5kW 120V SINGLE PHASE BEFORE YOU BEGIN CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS
More informationQuest Power Electric Heat EHS 62 Pro
Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection
More informationSTOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.
STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts
More informationMODEL CDB8 INSTALLATION INSTRUCTIONS
REV 0417 TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com SUITABLE FOR SIDE WALL OR
More informationLiebert CSU3000 Chiller
CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Model: S0000-AL2-C1D1-DB1
More informationAC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationWhirlpool Bathtub Model Number: MT618
INSTALLATION AND OWNER'S MANUAL Whirlpool Bathtub Model Number: MT618 Please carefully read these instructions before you begin to install the products. 07/11 Rev A P/N:100056-03 Thank you for purchasing
More informationsanctuary walk-in bathtubs PROUDLY BROUGHT TO YOU BY
Thank you for choosing an Sanctuary Walk In Tub, the world s highest quality walk-in bathtub. Our mission at is to help you maintain independence over your essential bathing needs and to improve your overall
More informationwalk-in bathtubs Thank you for choosing an AmeriGlide Sanctuary Walk In Tub, the world s highest quality walk-in bathtub.
Thank you for choosing an AmeriGlide Sanctuary Walk In Tub, the world s highest quality walk-in bathtub. Our mission at AmeriGlide is to help you maintain independence over your essential bathing needs
More informationSF180 Installation Instructions
SF180 Installation Instructions 1 Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationHardwired Model Shown. WarmlyYours Infinity Towel Warmer Installation & Operation Manual
Hardwired Model Shown WarmlyYours Infinity Towel Warmer Installation & Operation Manual Thank you for choosing a finely crafted WarmlyYours Infinity towel warmer. The Infinity s radiant heat gently warms
More informationOperation & Installation Guide
ENGLISH Operation & Installation Guide Office / Security Safes with Key Lock DUPLICATE KEYS ARE NOT AVAILABLE FOR THESE SAFES Models 5410, 5440, 5445, 5465 Read this manual carefully and never store it
More informationCeiling Mount Air Purification System
Ceiling Mount Air Purification System HA-CMP-G2-R/HA-CMP-G2-OV Owner s Manual Table of Contents HealthyAir Series 1219 Filters 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap
More informationDisinfectant Boost System DBS-125 Owner's Manual
Disinfectant Boost System Owner's Manual www.medoraco.com 866-437 - 8076 info@medoraco.com _Owners_Manual_20180829 Table of Contents Disinfectant Boost System Owner's Manual Table of Contents Safety 1
More informationENCLOSURE AIR CONDITIONERS
ENCLOSURE IR CONDITIONERS Compact Series 2,000 BTUH Celebrating 20 Years of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will
More informationOwner s. Coolerr. comply. To view
Owner s Manual EC220W Evaporative Coolerr IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to install or use this evaporative cooler. For your safety, comply with all safety
More informationIAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide
Installation Manual and Owner s Guide IAQ Series Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application PCOB-09012-0--A - 9" PCO BULB PCOB-14024-0--A - 14" PCO BULB 67202220344 Revised 07-12
More informationCondensate Pump. Installation and Safety Instructions CP-16 CP
Condensate Pump Installation and Safety Instructions CP-16 CP-16-230 CP-16 CP-16-230 Rated Voltage 120 Volts / 60 Hz 220 Volts / 60 Hz (208-230) Rated Current Draw 1.9 Amps 1.0 Amps Input Type USA 3-prong
More informationInstallation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS
Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS (I)COMP-COOL50 (I)COMP-COOL50P Thank you for purchasing the (I)COMP-COOL50/(I)COMP-COOL50P Component Coolers. Please
More informationInstallation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4
Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4 569443 GENERL INFORMTION The RTY Series uses a magnetically biased, Hall-effect integrated circuit (I) to sense rotary
More informationIN020 Rev F Page 1 of 8
IN020 Rev F Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationAUTOMATIC SWINGING DOOR
AAADM American Association of Automatic Door Manufacturers AUTOMATIC SWINGING DOOR OWNER'S MANUAL Distributed by: Contents Section Page Caution 2 To Our Customers 2 Service Availability 3 Compliance with
More informationINTERMEDIATE GUIDE BRACKET
BAIL ASSEMBLY AND CHAIN TOP RAIL SUPPORT SIDE MOUNT RAIL SUPPORT INTERMEDIATE GUIDE BRACKET LIFT-OUT RAIL SYSTEM 4" & 6" LIFT-OUT RAIL SYSTEMS INSTALLATION MANUAL WITH REPAIR PARTS LIST NOTE! To the installer:
More informationHS Series Installation & Operating Instructions RadonAway
The World s Leading Radon Fan Manufaturer HS Series Installation & Operating Instructions RadonAway 3 Saber Way Ward Hill, MA 01835 www.radonaway.com P/N IN007-REV J 9/13 RadonAway Ward Hill, MA. HS Series
More informationINFRARED RADIANT HEATERS
IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design
More informationQuest Dry 105, 155, and 205 Dual
Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More information40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017
40/40 Duct Mount P/N 777670 Installation Guide Document Ref: TM777670, Rev. (3) June 2017 8200 Market Blvd, Chanhassen, MN 55317, USA Phone: +1 (973) 239 8398 Fax: +1 (973) 239 7614 Website: www.spectrex.net
More informationLittle Helios. Use Instructions Portable Barrel Burner. Toll Free: Phone: (+1)
Warranty GEI Works warrants these products against defects in material and workmanship under normal use and service for a period of six months. GEI Works obligation under this warranty is limited solely
More informationCOMBUSTION AIR SYSTEM Model: CAS-3
COMBUSTION AIR SYSTEM Model: CAS-3 This product is designed for use with any oil burning furnace, water heater, or boiler with 120 VAC control systems. It may also be used with more than one appliance.
More informationBUNN CWT-CS CWTF-CS BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)
BUNN CWT-CS CWTF-CS ILLUSTRATED PARTS CATALOG Designs, materials, weights, specifications, and dimensions for equipment or replacement parts are subject to change without notice. BUNN-O-MATIC CORPORATION
More informationIon Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction
More informationTECHNICAL MANUAL FLIGHT-TYPE DISHMACHINES Master/Clipper RC
TECHNICAL MANUAL FLIGHT-TYPE DISHMACHINES Master/Clipper RC Includes Installation, Operation, and Maintenance Instructions Insinger Machine Company 6245 State Road Philadelphia, PA 19135-2996 800.344.4802
More information