FANERGY Far more than just a fan.
|
|
- Brice Thornton
- 5 years ago
- Views:
Transcription
1 FANERGY Far more than just a fan. Protects emergency crews. Saves lives.
2 2 Rosenbauer FANERGY
3 FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest tilt adjustment, from -20 to + 20 Simple operating concept with flexible set-up distance from 2 to 7 m High performance fans in two sizes: 16" and 22" Modern design Can also be used for producing water mist and expansion foam 3
4 Rosenbauer FANERGY The first choice for firefighting. Essential for the safety of emergency crews. More safety for SCBA crews The fan, as an integral part of operational tactics in firefighting, supports emergency crews so that they can perform an inside fire attack as quickly and risk-free as possible. In certain situations, the fan is the only thing that makes an inside fire attack possible. Better visibility enables SCBA crews to operate more quickly on scene. This leads to many advantages essential for the safety of emergency crews: Shorter operating times Faster detection of missing persons Sense of safety for emergency crews (elimination of panic due to zero-vision) Better and faster orientation Reduced risk of scalding from steam A fan as the first unit on scene Thick smoke, poor visibility and high temperatures: often, there are difficult conditions that SCBA crews have to master when first attacking a fire in a burning building. The FANERGY high-performance fan can provide enormous relief in precisely these types of operations. As the first instrument in fire fighting, it is set up in front of the air intake and activated to bring great advantages and increased safety for emergency crews: Improved visibility through fast smoke extraction Smoke control in escape/rescue routes Reduction of temperatures in the burning object Minimisation of the risk of flashover Immediate supply of fresh air for emergency crews and persons trapped in smoke Increased chance of saving fire victims Rapid smoke extraction means the SCBA crew has easier and faster access to the fire zone. The temperature in a burning building can be reduced as well as the risk of flashover and backdraft of flue gases. Furthermore, for injured or missing persons trapped in the smoke, the immediate supply of fresh air can be a lifesaving measure. In short: risk for the emergency crews can be significantly reduced by the use of a FANERGY highperformance fan, and the chances of rescuing people in smoke-filled buildings increases substantially. 4
5 FANERGY Rosenbauer FANERGY high performance fans provide important preparatory work in firefighting operations. Less damage to property Tactical ventilation is not only crucial for the safety of emergency crews and missing persons, but damage to burning objects can also be drastically reduced. Rapid smoke extraction lowers temperatures in the building, allowing emergency crews to fight the fire faster and in a more targeted fashion. The resulting advantages are obvious: Reduced damage to buildings through faster firefighting Lower water damage due to more selective dispensing of extinguishing agent Minimised risk of collapse of the burning object by rapidly lowering the temperature Lower costs for fire damage repairs 5
6 Rosenbauer FANERGY The All In One Airflow Technology. More power and more volume. 6 Fan impeller and fan control unit The core piece of the All In One Airflow Technology is the fan unit. Another new feature is the patented fan control unit, which ensures a focused and powerful airflow. This creates a uniform, powerful airflow with an optimized flow pattern. Turbulence and air helices are minimized. This is made possible by the special design of the fan impeller, fan control unit, and the special aerodynamically shaped grille. The new fan unit also ensures an even better drafting performance and thus a better air supply.
7 FANERGY Rosenbauer Improved performance thanks to the optimised flow pattern The All In One Airflow Technology from Rosenbauer is a completely new concept in ventilation technology. The special design of the fan unit results in an optimized air flow pattern. With this new technology, other concepts such as overpressure and turbo ventilation are combined into one piece of technology. Tactical ventilation of any kind is possible with the new All In One Airflow Technology. The result: air is delivered into buildings in a targeted way with more pressure and more volume. Smoke is evacuated quicker from the object which is on fire, visibility is immediately better and the temperatures are reduced more quickly. Initial attack position (+20 ) Basement outflow (-20 ) Maximum tilt angle of -20 to +20 The fan unit can be swivelled at the push of a button and without any accessories from -20 up to +20. The stepless adjustment takes place quickly and easily thanks to a maintenance-free gas strut. This is a considerable advantage during operation due to shorter set-up times. The generous inclination angle ensures more flexibility and efficiency when using the fan. The inclination angle of +20 is optimal for overcoming obstacles. The negative angular position of -20 larger than any other fan on the market is ideally suited to ventilate down stairs, to basement areas and through light shafts. More efficient ventilation with the pull-out fan unit When unfolding the handle, the fan unit automatically lifts out. In this way, the fan is immediately in an angular position of 20. For the majority of operations, this is the ideal setting. It makes it easier to overcome obstacles in the access area of the building (e.g. stairs, platforms). In combination with the new All In One Airflow, the pull-put fan unit also ensures that the airflow reaches the object with maximum efficiency. 7
8 Rosenbauer FANERGY Operation is easier and safer than ever before Lift from the vehicle Fold handle bar upwards Nozzle automatically sw Flexible installation distance of 2 to 7 m The use of a fan protects emergency crews and can save the lives of persons subjected to smoke. The key to successful ventilation is proper use. Thanks to the new All In One Airflow Technology, all existing fan technologies are combined into one, and using it is easier than ever before. The fan can be placed at a flexible distance of 2 to 7 m in front of the air intake. For maximum air flow, a set up distance of approx. 2 m is recommended. 545 mm Smallest dimensions 545 mm 490 mm During the development of the completely new FANERGY series, the engineers at Rosenbauer were mindful to design powerful and multi-functional devices that are also compact. The result is the smallest fan in the 16" category when folded. Its minimal footprint leaves space in the vehicle for more equipment. 8
9 FANERGY Rosenbauer One operating concept for everything. Proper use in operation. 4 5 ivels into the attack position of +20 Position FANERGY at a distance of 2 to 7 m Power-up the FANERGY Safe option: LED light package The integrated LED light package is unique and ensures more safety for operations in the dark. The built-in LEDs are arranged centrally behind the fan unit to illuminate in the direction of the air opening and thus serve as an orientation aid for the SCBA crew. On the rear side of the fan, two LED elements ensure good visibility of the device, essential for safe operations in the dark. The LED light package is optional for all models. 9
10 Rosenbauer FANERGY A redevelopment with many refinements. Components and accessories. Pull-out fan unit When unfolding the handle, the fan unit is lifted out from the transport position and put into the initial attack position of +20. Inclination angle from -20 to +20. Centrally integrated water spray unit For the generation of water mist and expansion foam. Integrated air control with guard Provides a powerful and effective airflow. The fan is available in two sizes: with a fan unit of 16" or 22". Robust body The body is made of high quality plastic, has a powdered aluminium frame, stainless steel components and convinces with its durability. For the new FANERGY, rust and corrosion are not an issue. Chocks For stopping air inlets and outlets and/or doors, windows, elevators and shafts. Two chocks of non-slip silicone are included in the delivery. The fan provides receptacle options for up to 4 wedges. 10
11 FANERGY Rosenbauer Cushioned handle Secure and easy opening and closing of the handle through the built-in damping system. Exhaust adapter For dissipating the engine exhaust gases using a standard DIN-exhaust hose. Included in scope of delivery. LED light package For illumination of the controls and the working area of the fan. Two drive variants The new FANERGY can optionally be driven by combustion engine (B&S or Honda) or an electric motor. Fold-out stabiliser Cushions against backlash and ensures that the fan is stable and secure in its operating location. The FANERGY can even be positioned on uneven, sloping or soft terrain by means of the fold-old stabiliser. Transport wheels The wide transport wheels can handle any surface and are maintenance-free. Storage compartment for foam net The foam net is stowed directly on the device and is instantly accessible. It requires no additional storage space, which saves space in the vehicle and reduces the set-up time. 11
12 Rosenbauer FANERGY Water mist and foam use. New details and innovative ideas. Multi-purpose use With regard to operational tactics, two further characteristics of the FANERGY fan are interesting: water mist as well as expansion foam can be produced. The mobile high-performance fan is equipped with a central water spray unit. Due to the high throw range of the water mist, buildings, gas cylinders, hazardous goods containers, batteries, etc. can be cooled and protected from a safe distance. Effective suppression of dangerous gases and steam is also possible using the water mist. In addition, the fan performs a valuable service as an expansion foam generator. Central water spray unit Through the central placement of the water spray unit in the centre of the nozzle, the water mist can be applied with more air power than ever before. Thanks to the optimised air power of the FANERGY, a throw range of up to 20 m can be achieved. The flow rate at 7 bar is approx. 200 l. The handling is understandably fast and easy: no extra accessories, no adapters, and used in combination with the usual equipment of the fire department. The fire hose can be connected directly to the fan via a Storz C-connection, via which the FANERGY is supplied with water, thus discharging a water mist. Throw ranges of up to 20 m possible Central water spray unit 12
13 FANERGY Rosenbauer With air tube for foaming cellars and underground facilities. Foam net stowed in a small compartment Pull the foam net over the fan The fan as a foam generator The fan can even produce expansion foam when used in conjunction with the foam net. The net is stored in a small compartment directly below the housing of the fan, which allows it to be carried along at all times. It is simply pulled over the ventilator intake and fixed with a handle. Expansion foam can be produced by using a supplemental standard Z2 proportioner. The expansion foam can be introduced to firefighting by air hoses in basement areas or underground facilities. Alternatively, the fan can be used on turntable ladders to convey foam to roofs or sources of fire above ground. 13
14 Rosenbauer FANERGY Two drive variants. Combustion engine The powerful version. The FANERGY high performance fan with combustion engine is the most powerful and lightest model. It is available in two different sizes with 16" and 22" diameters. Two 1-cylinder engines are available: from Briggs & Stratton or from Honda. Technical data V16 V22 Propulsion engine B&S 1-cylinder 4.8 kw (6.5 hp) or Honda 1-cylinder GX kw (6.5 hp) Air outlet diameter approx. 16"/410 mm approx. 22"/560 mm Air flow rate approx. 23,900 m 3 /h approx. 36,100 m³/h Effective air flow rate approx. > 50,000 m 3 /h approx. > 65,000 m³/h Dimensions (W x H x D) 545 x 490 x 545 mm 640 x 695 x 500 mm Weight (filled with oil, empty fuel tank) approx. 41 kg approx. 46 kg Fuel/tank capacity Running time with one tankful Lead-free gasoline >91 octane/approx. 3 l approx. 110 min. at full capacity 14
15 FANERGY Rosenbauer Electric motor The universal, quiet and environmentally friendly alternative FANERGY high performance fans with electric motors have a number of strengths: they are quiet, environmentally friendly, and exhaust-free. The power is steplessly adjustable from %. Its value is shown on a convenient display which is also visible in the dark. The integrated starting current limiter ensures that the drive functions smoothly with a 5 kva power generator. FANERGY models with electric motors can also be connected to any 230 V household socket using the shock-resistant plug. Interior setup is possible without reservation. The greatest advantage of the electric fan is that it can operate in any orientation, and its airflow can be used vertically and horizontally. For example, the fan can be placed facing a basement or sewer opening. This makes it universally applicable and flexible in terms of positioning. Technical data E16 E22 E16Ex* Explosion protection Ex II 3G C T3 Propulsion engine 230 V, 2.2 kw continuously adjustable 400 V / 1.85 kw Air outlet diameter approx. 16"/410 mm approx. 22"/560 mm approx. 16"/410 mm Air flow rate approx. 14,900 m 3 /h approx. 31,000 m³/h approx. 14,900 m 3 /h Effective air flow rate approx. > 30,000 m 3 /h approx. > 61,000 m³/h approx. > 30,000 m 3 /h Dimensions (W x H x D) 545 x 490 x 545 mm 640 x 695 x 500 mm 569 x 630 x 460 mm Weight approx. 45 kg approx. 50 kg approx. 47 kg *All models in the NEW FANERGY 2016 product range except the E16Ex variant 15
FANERGY Far more than just a fan.
FANERGY Far more than just a fan. Protects emergency crews. Saves lives. 2 Rosenbauer FANERGY FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest
More informationDirect-Drive Gas Power Blowers
Direct-Drive Gas Power Blowers Tempest Direct-Drive Gas Power Blowers were some of the first units designed and used on the fire ground. With a level a durability and performance backed only by the Tempest
More informationChapter 17 Test. Directions: Write the correct letter on the blank before each question.
Chapter 17 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe initial factors to consider when suppressing structure fires. 1. Which strategy
More informationRLS2000, RLS1000 LED Lighting Systems
RLS2000, RLS1000 LED Lighting Systems Powerful. Compact. Multifunctional. Rosenbauer RLS2000, RLS1000 Portable battery-led lighting systems Turns night into day. The multi-functional Rosenbauer LED lighting
More informationEasy-to-read controller with large rheostat knob and start/stop switch. Explosion proof motor
GFCI Compatible Variable Speed Blowers The VSG Variable Speed drive and motor provide enhanced ventilation capabilities. Use low speeds for quiet operation during removal of fumes and odors. Use high speeds
More informationRLS2000, RLS1000 LED Lighting Systems
RLS2000, RLS1000 LED Lighting Systems Powerful. Compact. Multifunctional. Rosenbauer RLS2000, RLS1000 Portable battery-led lighting systems Turns night into day. The multi-functional Rosenbauer LED lighting
More informationMistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM 2 MistMax Low pressure water mist fire suppression skid Our modular fire skid is customised to suit your
More informationMistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. 2 MistMax Low pressure WaterMist fire suppression skid Our modular fire skid is customised to suit your specific
More informationDIRECT-DRIVE GAS POWERED BLOWERS SPECIAL OPERATIONS BLOWERS
DIRECT-DRIVE GAS POWERED BLOWERS Tempest Direct-Drive Gas Power Blowers were some of the first units designed and used on the fire ground. With a level a durability and performance backed only by the Tempest
More informationAdditional Materials: Instructor s PowerPoint, Question Files
Course Delivery Formats: Online Interactive Course Online Streamed Video DVD Additional Materials: Instructor s PowerPoint, Question Files When it comes to mastering the basics for certification or refresher
More informationTYPHOON. New Ventilation Systems from RENZ :33
TYPHOON New Ventilation Systems from RNZ... www.typhoon-fans.com RNZ GmbH Feuerwehrservice your production, sales and service partner We, your production, sales and service partner would like to introduce
More informationManufacturer of RAMFAN Portable Ventilators. Fire Rescue Portable Ventilation Solutions for Smoke Removal
Manufacturer of RAMFAN Portable Ventilators Fire Rescue Portable Ventilation Solutions for Smoke Removal PPV RAMFAN positive pressure ventilation (PPV) fans are gas, water or electric powered to meet the
More informationSPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING
THE MOST ADVANCED TECHNOLOGY FOR PROTECTING SPECIAL HAZARDS There are numerous hazards where the use of dry chemical is the best option for firefighting, and where the use of portable fire extinguishers
More informationWith combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data
With combustion engine HD 801 B Cold water high-pressure cleaner with Honda 5.5hp petrol engine for use where no electrical connection is available. Equipment: Trigger gun Extended highpressure trigger
More informationIMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)
IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I) By Lt. Mike Mason As we have stated previously there are two prominent areas that drive every fire ground and that is
More informationOPERATING INSTRUCTIONS
EN DEHUMIDIFIER OPERATING INSTRUCTIONS Read the instructions carefully before operating or servicing the dehumidifier. Observe all the safety instructions; failure to observe the instructions may lead
More informationNEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems
NEW Energy systems Thermotank Quadroline The new generation of plastic storage tanks living full of energy Water provides a vital basis for life. It transfers heat in an environmentally friendly way and
More informationHot water super class HDS 12/18 4S *AU
Hot water super class HDS 12/18 4S *AU Our new medium and super class hot water high-pressure cleaners not only clean exceptionally well, they are also extremely rugged and simple to operate. The new ECO
More informationDCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS
DCN: 4.05.01 ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS 4. FIRE SCENE OPERATIONS 4.1 FIREFIGHTING OBJECTIVES 4.1.1 The objectives of firefighting are to protect life and property
More informationMASTER COURSE OUTLINE
A. FIRE 1100 Firefighter I B. COURSE DESCRIPTION: MASTER COURSE OUTLINE This course is designed to cover the necessary skills to perform the basic duties of firefighting including thought processes used
More information- CONSTRUCTION FIRE SAFETY STANDARDS
SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Construction Planning All construction sites shall plan and sequence their construction activities to ensure the early installation and operation of permanent
More informationChapter 3 FF II Fire Department Communications
Chapter 3 FF II Fire Department Communications After completing this lesson, the student shall be able to discuss on-scene communications and postincident reports. 1. Describe the aspects that make up
More informationTopic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours
Topic: Mechanical Ventilation Refresher Reference #: DG 14-07 Level of Instruction: In service personnel Time Required: 3 hours Instructor Preparation: The purpose of this drill is to conduct refresher
More informationPOSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS
FIRE EXTINGUISHING INSTALLATIONS SECTION POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS Version 1 29-09-04 0 Eurofeu position paper on water mist for fire fighting applications 1 Scope The
More informationONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY
122016 ONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY SAVE AND SURE For over 2 decades, the Dutch company BMT Fire & Rescue has been the no. 1 specialist for the design, production, renovation
More informationCold water compact class HD 5/15 C
Cold water compact class HD 5/15 C Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to
More informationTUNNEL FANS STANDARD AND HOT SMOKE
TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC
More informationCI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS
CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing
More information5 Key Stages to Risk Assessment
5 Key Stages to Risk Assessment Stage 1: Identify Fire Hazards For a fire to start, three things are needed: A source of ignition Fuel Oxygen If any one of these is missing, a fire cannot start. Taking
More information- CONSTRUCTION FIRE SAFETY STANDARDS
SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Hot Work Permits All construction sites shall implement a system of Hot Work Permits for all work activities that generate heat, sparks or flames. All of the
More informationSelf Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev
Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev 1.0 03-07-2017 Description Self Expanding Foam Systems (SEFS) are the alternative solution to existing flammable and combustible liquid
More informationVARIO CARBON TECHNOLOGIE AG VARIO VARIOCARBON CARBON HIGH - PERFORMANCE FIREFIGHTING SYSTEMS
VARIOCARBON TECHNOLOGIE AG VARIO CARBON VARIO CARBON HIGH - PERFORMANCE FIREFIGHTING SYSTEMS CFRP - MATERIAL OF LIGHTNESS AND STRENGTH If technical limits have to be exceeded in order to meet sophisticated
More informationA Design So Smart It's Simple. AIR CONDITIONERS & HEAT PUMPS RUUD. We Thought of Everything... And Then Some.
RUUD A Design So Smart It's Simple. AIR CONDITIONERS & HEAT PUMPS We Thought of Everything... And Then Some. We talked to a lot of dealers before we re-engineered our air conditioner and heat pump line.
More informationEnergy Conservation with PARAG Energy Efficient Axial Flow FRP Fans
PARAG FANS & COOLING SYSTEMS LTD. Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans Registered Office & Works Plot No.1/2B & 1B/3A, Industrial Area No.1 A.B.Road, Dewas 455001 (M.P.)
More informationWasher Extractors TWE 10-15
Washer Extractors TWE 10-15 Standard Features & Benefits Options Freestanding, high spin washer Dual heating (electric & steam) selectable through the control Compact & modern space-saving design Stainless
More informationIMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G Ref. T4/4.01 IMO E MSC/Circ.911 4 June 1999 INTERPRETATIONS OF FIRE
More informationWhere There's Smoke. Warrant Article 4 - New Fire Station
Warrant Article 4 - New Fire Station Where There's Smoke On Saturday, March 17, 2018 at 9 am, the citizens of Warner will gather for our annual Town Meeting at the Town Hall. One of the obvious hazards
More informationFull-size Classic Hot Water Pressure Washers. Powerful, user-friendly and fuel-efficient
Full-size Classic Hot Water Pressure Washers Powerful, user-friendly and fuel-efficient 2 The next stage of innovation Kärcher s full-size classic hot water pressure washers are exceptional cleaners in
More informationHD 5/12 C + Mobility. Accessory storage
HD 5/12 C + A new compact commercial machine for extended use. With its compact dimensions, robust construction and fantastic manoeuvrability, this unit is a credit to the compact class. 1 Mobility 3 Accessory
More informationSmoke Management in High-Rise Structures
Smoke Management in High-Rise Structures Most modern building codes define a high-rise structure as a building greater than 75 feet in height from the lowest level of fire department vehicle access to
More informationEssentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)
Essentials of Fire Fighting, Fourth Edition Transition Guide Chapter 1: The History of the Fire Service (Essentials, Chapter 1) This chapter covers the history of the fire service, the organization of
More informationPLUS SIZE EXTINGUISHERS CEASEFIRE PLUS
PLUS SIZE EXTINGUISHERS CEASEFIRE PLUS Ceasefire Plus 01 THE BIGGEST CONTRIBUTOR TOWARDS FIRE ACCIDENTS IS SHORT CIRCUIT. It s a well-known fact that the major contributor towards fire accidents today
More informationWith combustion engine HD 728 B Cage. Equipment: Trigger gun Extended highpressure. Technical data
With combustion engine HD 728 B Cage Cold water high-pressure cleaner with Honda 5.5hp petrol engine for use where no electrical connection is available. With protective tubular steel frame. Equipment:
More informationAmerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.
Amerex Fire Suppression Systems Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond. Quality is Behind the Diamond. Diamonds have long been a symbol for quality. At Amerex
More informationThe Professional Choice
The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation
More information4 Storage cabinets SCALA
Storage cabinets Our SCALA laboratory furniture system provides you the greatest possible selection of storage variations for quick access and safe storage. All storage cabinets are variably equipable
More informationXpert HD Xpert HD 7140, ,
Xpert HD 7140 Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. TECHNICAL
More informationUSER MANUAL KGNVCTBVAA
USER MANUAL KGNVCTBVAA IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
More informationFirefighting operations on multi-tiered vehicle stacking buildings F5-13 GD
DESIGNER S GUIDE Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD Introduction When to use Scope Use this chapter to provide a consistent Fire and Emergency New Zealand position
More informationEASTERN ARIZONA COLLEGE Fire Department Operations I
EASTERN ARIZONA COLLEGE Fire Department Operations I Course Design 2015-2016 Course Information Division Allied Health Course Number FSC 101 Title Fire Department Operations I Credits 6 Developed by B.K.
More informationRapid Intervention Team
3.2.1.2 Rapid Intervention Team YOUR ORGANIZATION STANDARD OPERATING PROCEDURES/GUIDELINES TITLE: Rapid Intervention Team NUMBER: 3.2.1.2 PREPARED BY: SECTION/TOPIC: Fire Suppression Risk Management ISSUE
More informationCumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07
Standard Operating Guidelines Page: 1 of 6 15.07 Scope: Commercial properties shall include businesses, schools and shops with very limited special hazards. 15.0701 First engine placement: Positioning
More informationThe new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION
The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION Experience the external venetian blind 80 S in action! www.warema.com/80s The new WAREMA external venetian blind 80 S PROVEN THINGS
More informationIndustrial Ventilation Equipment
Using Air as a Tool Industrial Ventilation Equipment Rapid, Effective Site Ventilation Robust Durability Customizable Solutions Safe and Easy Operation Table of Contents Introduction About Tempest 1 About
More informationBased on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition
Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Alabama Fire College Airport Firefighter Instructional JPR Verification Sheet Full Name: Fire Department: This Instructional
More informationGround-engaging telehandler
Ground-engaging telehandler Reaching new heights in versatility. TH522 Loading, moving, lifting, placing - the Wacker Neuson TH522 handles a lot. But there s more. This highly versatile telehandler extends
More informationPATTERNS OF FIREFIGHTER FIREGROUND INJURIES
PATTERNS OF FIREFIGHTER FIREGROUND INJURIES Michael J. Karter, Jr. Fire Analysis & Research Division National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 www.nfpa.org November
More informationHigh-Pressure Water Mist systems for the protection of shopping centres in historical city centres
Danfoss Fire Fighting High-Pressure Water Mist systems for the protection of shopping centres in historical city centres Presenter: Antonio Terio October 25 th 2017, IWMC Rome 1 Introduction & Background
More informationCooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.
ENGIE Refrigeration supplies the right cooling for every process: from efficient chillers and modular re-cooling systems to turnkey solutions such as refrigeration containers or modules. Efficiency, sustainability,
More informationATTIC FIRES. Part 3 HEAVY SMOKE SHOWING
ATTIC FIRES Part 3 HEAVY SMOKE SHOWING ATTIC FIRE TACTICS HEAVY SMOKE SHOWING Size-Up Investigation Life Priority Follow-Up Changing Tactics Assign Resources Locate The Fire Salvage Fire Attack Overhaul
More information1 of 12. Spring Delights Sdn. Bhd. K HIGH PRESSURE WASHER K HIGH PRESSURE WASHER
Spring Delights Sdn. Bhd. K 2.350 HIGH PRESSURE WASHER Compact, versatile, robust - the K 2.350 with wheels is ideal for occasional use around the house. This practical high-pressure cleaner is designed
More informationGX200/ GX200L. Owner s Manual
GX200/ GX200L Owner s Manual Euramco Safety, Inc. 2746 Via Orange Way Spring Valley, CA 91978 USA USA 1.800.4.RAMFAN Tel +1.619.670.9590 Fax +1.619.670.7345 theteam@euramcosafety.com www.euramcosafety.com
More informationTechnologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230
Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec
More informationULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS Product Catalog HMAFIRE.COM FIRE
HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS 2018 Product Catalog HMAFIRE.COM 844.855.FIRE HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS Roots from Air Force Testing The story of HMA Fire
More informationFIRE RISK ASSESSMENT Self Assessment
FIRE RISK ASSESSMENT Self Assessment Important! This fire risk assessment form is to be filled in by the responsible person within a business or organisation. As this is a free download for the use of
More informationHot water compact class HDS 5/12 C *AU
Hot water compact class HDS 5/12 C *AU Standard accessories: Spray gun Extended, Easy Press Spray gun with Softgrip insert High-pressure hose 10 m Spray pipe 550 mm Power nozzle SDS system Anti-twist system
More informationAll NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.
IMPROVING BUILDINGS SAFETY THROUGH TECHNOLOGY All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive. We use the latest photoluminescent technology with high-grade Strontium
More informationU.S. Firefighter Disorientation Study Prepared by William R. Mora, Captain San Antonio Fire Department San Antonio, Texas.
U.S. Firefighter Disorientation Study 1979-2001 Prepared by William R. Mora, Captain San Antonio Fire Department San Antonio, Texas July 2003 Firefighter Disorientation, which is loss of direction due
More informationTechnical Information
How to design easily a smoke management system? Mechanical smoke extraction for enclosed car park Car park: specificity of the smoke extraction system Car parks are nowadays integrated directly inside
More informationWestbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm
Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm Scenario 2 1/2 Story Wood Frame Private Dwelling built early 1900 s. @ 1930 hours the department receives
More informationGeneral Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin
The purpose of a monthly self-inspection program is to identify unsafe conditions in the work environment and unsafe employee actions. Management can then correct these safety hazards, reducing the potential
More informationSafety training Monitor-based workstation Topics:
Safety training Monitor-based workstation Topics: Ergonomics Electrical appliances Explanations for escape and rescue plans Fire protection First aid Risks at the work station / in the work area Monitor-based
More informationLIFE SAFETY & RESCUE SOLUTIONS. Torches and lighting solutions COPY ONLY
Portable Fire equipment Fire protection systems fire system installations fire system servicing compliance fire safety training major projects LIFE SAFETY & RESCUE SOLUTIONS Torches and lighting solutions
More informationFirst Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM
First Revision No. 1-NFPA 1403-2015 [ Section No. 1.2.1 ] 1.2.1 The purpose of this standard shall be to provide a process for conducting live fire training evolutions to ensure that they are conducted
More informationHD 7/11-4 Cage Classic
HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure
More informationFully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified
Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual
More informationCondensation drying for industry and trade
Air dehumidifying 2011 Condensation drying for industry and trade Condensation drying for industry and trade 2011 DH 18 domestic dehumidifiers Development, production and sales: All from a single source
More informationautomatic FiReFighTing SYSTeMS in PainT booths
SPECIAL HAZARDS PROTECTION automatic FiReFighTing SYSTeMS in PainT booths hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable
More informationSolid biofuel solutions
Solid biofuel solutions Clean heat with locally produced fuel Solid biofuels are the individually most important component in the conversion to a sustainable energy mix. Heat production from wood based
More informationAUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS
SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS Hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable
More informationPortable Room Air Conditioner and Heat Pump
Installation, Operation & Maintenance Manual Portable Room Air Conditioner and Heat Pump PS-121B PSH-141A Thank you for purchasing our Portable Air Conditioner. French version of this manual is available
More informationBranch Solution Wood based panel plants. Fire protection solutions for wood based panel plants
Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is
More informationCalaer Marine add-on kit manual. 2kW Calaer air heater 4kW Calaer air heater
Calaer Marine add-on kit manual 2kW Calaer air heater 4kW Calaer air heater 1. Introduction and scope 1. Introduction and scope The Calaer marine add-on kit is designed to be used with the Calaer air
More informationHDS 6/14 C. Large tilting aid. eco!efficiency mode. Economical and environmentally friendly even during longer periods
HDS 6/14 C Single-phase hot water high-pressure cleaner with Eco mode, 1-button operation, integrated tanks, Easy Press gun with soft grip, continuous servo-control pressure/water flow regulation, etc.
More informationFIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED
COXDOME. FIRE JET SMOKE SYSTEMS FIREJET 165 24V / 48V SMOKE SYSTEMS CE EN12101-2 CERTIFIED DRIVEN BY DAYLIGHT WWW.JET-COX.CO.UK IN THE CASE OF A FIRE WITHIN A BUILDING MORE THAN 90% OF FATALITIES ARE CAUSED
More informationWARNING VILPRA WOOD WOOD HEATER MANUAL. Marketing: SpaDealers. Korsnäs FINLAND +358 (0)
VILPRA WOOD WOOD HEATER MANUAL Marketing: SpaDealers Korsnäs FINLAND +358 (0)10 239 5600 info@spadealers.eu www.spadealers.eu Manufacturer UAB VILPROS PRAMONÉ, Lithuania WARNING Heater must be under supervision
More information, A Product Catalog
IN DE TEXAS, A US MA 2015 Product Catalog Forget What You Know about Evaporative Cooling 100 years ago - Evaporative Cooling was developed (see graphic) and has been in use ever since. (Think Port-a-Cool)
More informationMACHINES ACR SERIES ACR RAMMER
MACHINES ACR SERIES ACR RAMMER The optimal balance and user-friendly handle of the Ammann ACR Rammers make these machines a joy to work with. 2 THE RIGHT FIT ON YOUR JOBSITE AMMANN ACR RAMMERS Ammann Rammers
More information... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the
More information... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the
More informationThe Professional Choice
The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation
More informationA totally renewable heat source
Up-To 44kW, 75kW, 88kW A totally renewable heat source www.central-boiler.co.uk Why choose a Central Boiler? How it works The E-Classic boiler makes heating with wood as simple and efficient as it gets.
More informationI. It shall be the responsibility of the department officers to implement this operating guideline.
Procedure Effective Date Rescinds HIGH RISE INCIDENTS New Reference FIRE CHIEFS ASSOCIATION OF CENTRAL OHIO Page 1 of 11 NORWICH TOWNSHIP FIRE DEPARTMENT SOG# 8 Purpose: The purpose of this procedure is
More informationMINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20
Piping Layout Design Introduction The performance requirements of the equipment are developed by design teams which normally include members from the different departments such as process, engineering,
More informationImportance of a Draught Regulator
Importance of a Draught Regulator The purpose of a chimney (stack) is to generate a draught (draft) that will transport smoke and fumes away from the point of combustion. The chimney design and arrangement
More informationFirefighting Robotic System. Reggie Grant Director, Advanced Programs - Dallas
Firefighting Robotic System Reggie Grant Director, Advanced Programs - Dallas Mission Statement The Fire Fighting Robotic System s s Program mission is to: Provide the wild-land land Firefighters with
More information"Let's provide you with a superior User Experience delivering Ease-of-Mind."
"Let's provide you with a superior User Experience delivering Ease-of-Mind." contents 2 Safety warnings...3 For the installer...3 For the user...3 Installation...4 Unpacking...4 Location...4 Electrical
More informationFIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES
10 FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Demonstrate procedures for assuming and transferring command at an emergency scene, utilizing an incident management system. REFERENCE: NFPA 1001,
More informationSecond Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement
Second Revision No. 1-NFPA 1410-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 1500, Standard on Fire Department
More informationThe Possibilities of Applying Mobile Ventilators In the Process of Indoor Fire-fighting
ZRÍNYI MIKLÓS NATIONAL DEFENCE UNIVERSITY Council of Doctors GÉZA ZÓLYOMI fireman lieutenant colonel The Possibilities of Applying Mobile Ventilators In the Process of Indoor Fire-fighting Short author
More information