TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

Size: px
Start display at page:

Download "TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409"

Transcription

1 TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact cabinets along with return air options in both the upflow and horizontal positions allow this unit to fit into tight spaces such as attics, crawl spaces, and closets. NOTE: For matching condensing units and performance data, refer to condenser technical guides. FEATURES ABINET -The compact and sturdy cabinet is protected with a durable, attractive finish to prevent rust. The cabinet is also insulated to prevent cabinet sweating. F6FP models have 3/4 insulation. BLOWERS - Blowers are sized to circulate air both quietly and efficiently. The direct-drive, multi-speed, efficient X-13 motors provide a selection of air volume to match any application. Motor speeds may be selected via quick connect terminal at the motor. Slide-out blower/motor assemblies provide for easy servicing. OILS - The rifled tube coil/aluminum fin coils produce high performance ratings and provide long lasting quality. The coils are capable of bottom return air in the upflow position, and right or left end return air in the horizontal position. FLEX-OILS - For added application flexibility, an orifice metering device or R-22 or R-410A TXV should be installed on Flexcoils in the field to meet the required refrigerant choice. ELETRI HEATERS - providing up to 25kW of heat are available as field installed accessories. Electric heaters are available in both single and three phase. EAS INSTALLATION - These fan coil units are designed to provide the lowest total installation cost. Accessible color coded control wiring, top and side power wiring knockouts, easy to install drain connections and electric heaters all combine to minimize installed cost on every job. ONTROL BOARD - The control board is equipped with low voltage terminal strips for easy installation. The control board is also equipped with plug-in receptacles for the auxiliary heaters. ISO 9001 ertified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at Additional rating information can be found at FOR DISTRIBUTION USE ONL - NOT TO BE USED AT POINT OF RETAIL SALE

2 DIMENSIONS ALL DIMENSIONS ARE IN INHES AND ARE SUBJET TO HANE WITHOUT NOTIE. ERTIFIED DIMENSIONS WILL BE PROVIDED UPON REQUEST. SHIPPIN BRAKET* 10-3/8 REMOVE PRIOR 21-19/32 TO INSTALLATION F (2 SREWS) 10-3/8 3/4 F 4-1/8 J J DRAIN ONNETIONS FOR HORIZONTAL APPLIATIONS 4 VAPOR OPENIN LIQUID OPENIN D K A REAR 10-3/8 7-1/2 =DRAIN PAN FOOTPRINT MAX. FILTER LENTH (21 INHES) MAX. FILTER WIDTH (B MINUS 1-1/2 INHES) 3/4 3/4 K /2 2 DRAIN ONNETIONS FOR UPFLOW APPLIATIONS B FILTER AESS E 18-3/8 BOTTOM VIEW 24-1/2 Model /4 BOTTOM OPENIN Dimensions Model 1 F6FP018H06T** 40-3/ All models only available with factory installed horizontal drain pan. 2. Actual conduit size is shown in parenthesis. Dimensions Wiring K.O.s 2 A B J K D E F Height Width Depth Power ontrol 14-7/8 16-1/2 Refrigerant onnections Line Size F6FP024H06T** 40-3/ /8 16-1/2 7/8 (1/2) 3/4 12-1/8 F6FP030H06T** 40-3/4 21-1/2 18-3/ /8 (1) 3/4 22 F6FP036H06T** 40-3/4 21-1/2 18-3/8 20 7/8 (1/2) 3/8 7/8 F6FP042H06T** 50-3/ /8 22-1/2 7/8 7/8 (1/2) F6FP048H06T** 50-3/ /8 20-7/8 22-1/2 1-3/8 (1) 7/8 1-23/32 F6FP060H06T** /2 21-1/2 23-1/ /32 7/8 Liquid Vapor 5/8 2 Johnson ontrols Unitary Products

3 OIL TEHNIAL DATA Application Refrigerant onnection Type Face Area (Sq. Ft.) Deep Rows Fins Per Inch oil Slab Size H W Tube eometry Tube Dia UT-B-0409 Fin. Type Metering Device F6FP018H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed F6FP024H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed F6FP030H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed F6FP036H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed F6FP042H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed F6FP048H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed F6FP060H06T** A/ & HP Sweat x.886 3/8 Enhanced Field Installed OOLIN APAIT Blower Model Rated FM F6FP018H06T** 615 F6FP024H06T** 830 F6FP030H06T** 1050 F6FP036H06T** 1185 F6FP042H06T** 1400 F6FP048H06T** 1600 F6FP060H06T** 1850 Entering Air F Evaporator Temperature and orresponding Pressure F / PSI (Dry / Wet Bulb) 35 / / / / 84.0 Upflow / Horizontal Positions Only 85 / / / / / / / / / / / / / / / / / / / / / / / / / / / / Johnson ontrols Unitary Products 3

4 AESSORIES Refer to Price Manual for specific model numbers. VERTIAL SUSPENSION KIT - The suspension kit is designed to be used with all sizes of fan coil units whenever the application requires vertical suspension of the unit. ELETRI HEATERS - shown under Electrical Data include sequencers and temperature dual limit switches for safe, efficient operation. ircuit breakers are provided where shown. BOLT-ON THERMAL EXPANSION VALVE - R-22 and R-410A TXV kits are available for enhanced efficiency. EXTERNAL FILTER RAK - The F6FP air handler requires an external filter rack be used, as there are no provisions for internally installed filter. For multi-position applications, specify filter rack assembly 1FR0824, which includes a 1 permanent filter. For horizontal applications, use filter rack 1RF0724. LIMITATIONS These units must be wired and installed in accordance with all national and local safety codes. Voltage limits are as follows: Normal Operating voltage Range 1 1. Utilization range A in accordance with ARI Std Air flow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units: Entering Air Temperature Limits Wet Bulb Temp. ºF Dry Bulb Temp. ºF Min. Max. Min. Max EXTENDED AIRFLOW DATA 1 FOR 230 VOLT - HEAT PUMP MODELS Blower Motor Speed 230 Volt External Static Pressure - IW High Med-High F6FP018H06T** Medium Med-Low Low High Med-High F6FP024H06T** Medium Med-Low Low High Med-High F6FP030H06T** Medium Med-Low Low High Med-High F6FP036H06T** Medium Med-Low Low High Med-High F6FP042H06T** Medium Med-Low Low High Med-High F6FP048H06T** Medium Med-Low Low High Med-High F6FP060H06T** Medium Med-Low Low NOTE: Air flow data shown above 1/2 w.c. external static pressure is for REFERENE ONL. Maximum allowable external static when electric heat is used is limited to 1/2 w.c. Maximum allowable external static pressure may also be limited by minimum FM requirements for proper Heat Pump operation. 1. Includes Return Air Filter and Largest Electric Heater. All F*FP series air handler units are UL Listed up to 1/2" w.c. external static pressure, including air filter, wet coil, and largest kw size heater. 4 Johnson ontrols Unitary Products

5 EXTENDED AIR FLOW DATA 1 FOR 208 VOLT - HEAT PUMP MODELS F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Blower Motor Speed 208 Volt External Static Pressure - IW 1. Includes Return Air Filter and Largest Electric Heater. All F*FP series air handler units are UL Listed up to 1/2" w.c. external static pressure, including air filter, wet coil, and largest kw size heater UT-B High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low NOTE: Air flow data shown above 1/2 w.c. external static pressure is for REFERENE ONL. Maximum allowable external static when electric heat is used is limited to 1/2 w.c. Maximum allowable external static pressure may also be limited by minimum FM requirements for proper Heat Pump operation. APPLIATION FATORS-RELATED FM VS. ATUAL FM % Of Rated Airflow 80% 90% RATED FM 110% 120% apacity Factor Johnson ontrols Unitary Products 5

6 Physical and Electrical Data MODEL F6FP018H06T** F6FP240H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Blower - Diameter Width 10x6 10x8 10x8 10x8 11x10 11x10 11x10 Motor HP 1/3 1/3 1/3 1/2 3/4 3/4 3/4 Nominal RPM Voltage 208/ /230 Amps Full Load Type Disposable/Permanent Filter 1 Size 16x20x1 16x20x1 20x20x1 20x20x1 20x20x1 22x20x1 24x20x1 Permanent Type Kit 1PF0601BK 1PF0601BK 1PF0602BK 1PF0601BK 1PF0602BK 1PF0603BK 1PF0604BK Shipping/Operating Weight (lbs.) 98/93 105/ / / / / / Field Supplied. ELETRIAL DATA - ooling Only Minimum ircuit Total Motor Amps ampacity 208V 230V 208V 230V 1. O..P. = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay Fuse. Max. O..P. 1 Amps/ Type Minimum Wire Size A.W.. F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** KW & MBH ONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT FOR 230V OPERATION MULTIPL 240V TABULATED KW & MBH B Johnson ontrols Unitary Products

7 ELETRIAL DATA / F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Heater 1 Model 2HK* B MAX. STATI & MIN. FM 1. 0 or as follows: 0 = No Breaker, 1 = Breaker. 2. See onversion Table below: 3. If first stage heat or 66 is connected to W1, otherwise refer to this table. Total Heat 2 KW Staging UT-B-0409 KW MBH W1 Only W2 Only W1 + W2 Static Tap 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V Low HK* B 0.5 Low HK* B Low HK* B Low HK* B 0.5 Low HK* B Low HK* B Low HK* B Low HK* B Low HK B Medium HK* B Low HK* B Low HK* B Low HK B Medium HK* B Low HK* B Low HK* B Low HK B Low HK B Med-Low HK B Med-Low HK* B Med-Low HK B Med-Low HK B Med-Low HK B Med-Low HK* Medium HK* Medium HK* Medium HK Medium HK Medium HK Medium HK Medium NOTE: All models available with factory installed horizontal drain pan. Johnson ontrols Unitary Products 7

8 ELETRIAL DATA - 1 (SINLE SOURE POWER SUPPL) - OPPER WIRE F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Heater Model 1 Heater Amps 240V Min. ircuit Ampacity 1. 0 or 1 as follows: 0 = No Breaker, 1 = Breaker 2. OP = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay fuse. Field Wiring Max. O..P. 2 Amps/Type 75 Wire Size - AW 208V 230V 208V 230V 208V 230V 2HK* B HK* B HK* B HK* B HK* B HK* B HK* B HK* B HK* B HK B HK* B HK* B HK* B HK B HK* B HK* B HK* B HK B HK* B HK* B HK* B HK B HK B HK B /0 4HK* HK* HK* HK HK HK HK /0 8 Johnson ontrols Unitary Products

9 ELETRIAL DATA - 1 Ø (MULTI-SOURE POWER SUPPL) - OPPER WIRE Min. ircuit Ampacity Max. O..P. 1 Amps/Type 75 Wire Size - AW Heater Model ircuit ircuit ircuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V F6FP030H06T** 2HK B 26.2/ / /30 50/60 10/10 8/6 F6FP036H06T** 2HK B 27.2/ / /30 50/60 10/10 8/6 2HK B 28.8/ / /30 50/60 10/10 8/6 F6FP042H06T** 2HK B 30.1/ / /35 50/60 10/8 8/6 2HK B 30.8/ / /40 50/60 8/8 8/6 F6FP048H06T** 2HK B 53.3/ / /70 50/60 6/4 8/6 2HK B 31.8/ / / /40 50/60 50/60 8/8 8/6 8/6 4HK / / / / 25 6 / 6 10 / 10 F6FP060H06T** 4HK / / / / 50 8 / 6 8 / 8 4HK / / / / 50 6 / 6 8 / 8 4HK / / / / / / 25 8 / 6 8 / 8 10 / OP = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay fuse. ELETRIAL DATA - 3 Ø - 208/ MAX. STATI Total Heat 1 KW Staging 2 Heater Model & MIN. FM KW MBH W1 Only W2 Only W1 + W2 Static Tap 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V F6FP018H06T** 2HK B 0.5 Low F6FP024H06T** 2HK B 0.5 Low F6FP030H06T** 2HK B 0.5 Low HK B 0.5 High F6FP036H06T** 2HK B 0.5 Low HK B 0.5 High F6FP042H06T** 2HK B 0.5 Low HK B 0.5 Low F6FP048H06T** 2HK B 0.5 Med Low HK B 0.5 Med Low HK Medium F6FP060H06T** 4HK Medium HK Medium See onversion Table below. 2. If first stage heat is connected to W1/66, otherwise refer to Table below. ELETRIAL DATA (SINLE SOURE POWERSUPPL) - OPPER WIRE Field Wiring Heater Min. ircuit Ampacity Max. O..P. 1 Amps 75 Wire Size - AW 208V 230V 208V 230V 208V 230V F6FP018H06T** 2HK B F6FP024H06T** 2HK B F6FP030H06T** 2HK B HK B F6FP036H06T** 2HK B HK B F6FP042H06T** 2HK B HK B F6FP048H06T** 2HK B HK B HK F6FP060H06T** 4HK HK O..P. = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay fuse. Johnson ontrols Unitary Products 9

10 FIELD WIRIN ONNETION - OOLIN ONL FIELD WIRIN ONNETION - WITH HEATER KIT THERMOSTAT R W OUTDOOR UNIT THERMOSTAT R W * OUTDOOR UNIT FAN OIL UNIT R W2 W1 O FAN OIL UNIT R W2 W1 O * NOTREQUIREDON2OR5KW FIELD WIRIN ONNETIONS - OOLIN MODELS WITH ELETRI HEAT WIRIN Air Handler ontrol Wiring Typical A/ - ooling only Applications THERMOSTAT AIR HANDLER BOARD 1-STAE AIR ONDITIONIN R R Air Handler ontrol Wiring Typical A/ with Electric Heat Applications AIR HANDLER THERMOSTAT BOARD 1-STAE AIR ONDITIONIN R R /2 /2 W1 1 1 W2 W2 W2 W2 W1 HUMIDISTAT* W1 W1 HUMIDISTAT* O O HUM HUM X/L X/L OM OM * Dehumidification control connection ( Humidistat jumper on FM selection board must be removed). FIELD WIRIN ONNETIONS - SINLE STAE HEAT PUMP ONTROL WIRIN - Air Handler And Newer UP Single Stage HP Systems Single Stage H/P with Standard Demand Defrost ontrol Board THERMOSTAT AIR HANDLER BOARD HEAT PUMP R R R /2 1 W2 W2 ** E W1 W1 66 W/W1 O O W O HUM HUMIDISTAT* X/L X/L X/L OM * Dehumidification control connection ( Humidistat jumper on FM selection board must be removed). NOTES: 1. Terminal on Air Handler ontrol Board must be connected for full FM and applications requiring 60 second Blower Off Delay for SEER enhancement. 2. Optional Dehumidification Humidistat contacts open on rise. 3. For F4FV model - Remove Humidistat Jumper on FM Selection Board - if used. 4. For F4FV model - For Heat Pump Applications - Remove Heat Pump Jumper on FM Selection Board. 5. To change quantity of heat during HP defrost cycle - Reverse connections at W1 and W2 on Air Handler ontrol Board. 10 Johnson ontrols Unitary Products

11 TPIAL INSTALLATION POWER WIRIN TO MAIN POWER SOURE SUPPL AIR POWER WIRIN ONTROL WIRIN REFRIERANT LINES THERMOSTAT TO ONDENSATE DRAIN FILTER AESS LOUVERED ELETRI HOT WATER HEATER (Must comply with water heater installation instructions) TPIAL APPLIATIONS UPFLOW HORIZONTAL RIHT HAND APPLIATION LEFT HAND APPLIATION Johnson ontrols Unitary Products 11

12 Subject to change without notice. Printed in U.S.A. opyright 2009 by Johnson ontrols, Inc. All rights reserved. Johnson ontrols Unitary Products 5005 ork Drive Norman, OK UT-B-0409 Supersedes: UT-A-0109

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact

More information

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C) TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409 INSTALLATION MANUAL SINGLE PIEE AIR HANDLERS MODELS: F6FP018** - 060** ISO 9001 ertified Quality Management System SAFETY................................................ 1 SPEIFI SAFETY RULES AND PREAUTIONS...............

More information

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209 INSTALLATION MANUAL SINGLE PIEE AIR HANDLERS MODELS: F*FP ISO 9001 ertified Quality Management System SAFETY................................................1 SPEIFI SAFETY RULES AND PREAUTIONS...............2

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified

More information

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105) TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION SINGLE PIECE AIR HANDLERS Supersedes: 535.02-N2V (598) 535.02-N2V (199) HEAT PUMP MODELS F+RP / F+FP018 thru 060 and COOLING MODELS F+RC / F+FC024 thru 036 035-14363 GENERAL This

More information

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION SINGLE PIECE AIR HANDLERS Supersedes: 535.02-N2V (600) 535.02-N2U (900) HEAT PUMP MODELS F2RP / F2FP018 thru 060 and COOLING MODELS F2RC / F2FC024 thru 036 035-14520-000 Rev. B

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195) STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: 535.02-N2Y (795) 535.02-N2Y (1195) HEAT PUMP MODELS F1RP / F1FP018 thru 060 and COOLING MODELS F1RC / F1FC018 thru 036 035-13620

More information

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIEE VARIABLE SPEED AIR HANDLERS MODELS: AV*() SERIES ISO 9001 ertified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF:

More information

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL MODULA VAIABLE SPEED AI HANDLES MODELS: MV ISO 9001 ertified Quality Management System GENEAL.............................................. 1 SAFETY................................................

More information

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES ISO 9001 Certified Quality Management System GENERAL.............................................. 1 SAFETY................................................

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

TECHNICAL GUIDE. AFFINITY MODELS: PS8*DH GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW/HORIZONTAL FURNACES STANDARD & Low NOx DESCRIPTION WARRANTY

TECHNICAL GUIDE. AFFINITY MODELS: PS8*DH GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW/HORIZONTAL FURNACES STANDARD & Low NOx DESCRIPTION WARRANTY TEHNIAL UIDE AFFINIT MODELS: PS8*DH AS-FIED HIH EFFIIEN SINLE STAE DONFLO/HOIZONTAL FUNAES STANDAD & Low NOx NATUAL AS 40-130 MBH INPUT EFFIIEN ATIN ETIFIED DESIPTION These high efficiency, downflow/horizontal

More information

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS 23 SEER Residential System Indoor Section M1200 Product Line PAH2VM Series Variable Speed Air Handler C5 Series Residential Indoor Coils with EXV 2 M1200 12 YEAR ALL PARTS LIMITED

More information

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIEE, 3 POSITION EM AIR ANDLERS MODE: AV SERIES ISO 9001 ertified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

TECHNICAL GUIDE MODELS: GY9F*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 95% AFUE DESCRIPTION WARRANTY FEATURES YTG-B-0907

TECHNICAL GUIDE MODELS: GY9F*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 95% AFUE DESCRIPTION WARRANTY FEATURES YTG-B-0907 TEHNIAL UIDE MODELS: 9F*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO FUNAES 95% AFUE NATUAL AS 48-96 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System DESIPTION These ategory IV, highly

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

TECHNICAL GUIDE AFFINITY MODELS: PS9*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% TO 94% AFUE

TECHNICAL GUIDE AFFINITY MODELS: PS9*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% TO 94% AFUE TEHNIAL UIDE AFFINIT MODELS: PS9*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO SINLE STAE FUNAES 92% TO 94% AFUE NATUAL AS 40-135 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System Due

More information

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIEE, POSITION EM AIR ANDLERS MODE: AV SERIES ISO 900 ertified Quality Management System GENERAL.............................................. SAFETY................................................

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3 FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides

More information

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG: Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

AIR HANDLERS AIR HANDLERS

AIR HANDLERS AIR HANDLERS FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard

More information

TECHNICAL GUIDE MODELS: GM9S*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES BTG-A-0407

TECHNICAL GUIDE MODELS: GM9S*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES BTG-A-0407 TEHNIAL UIDE MODELS: M9S*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO FUNAES 92% TO 94% AFUE NATUAL AS 40-135 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System DESIPTION These ategory

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC INSTALLATION MANUAL SINGLE PAKAGE HEAT PUMP/ELETRI MODELS: PHE4 Series (2-5 Ton) LIST OF SETIONS GENERAL INFORMATION................................ 1 SAFETY...............................................

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE TEHNIAL UIDE Echelon MODELS: F9T AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED Due to continuous product improvement, specifications

More information

SPLIT SYSTEM HEAT PUMPS "ERC" Series

SPLIT SYSTEM HEAT PUMPS ERC Series 515.18-TG1Y (299) TECHNICAL SPECIFICATIONS SPLIT SYSTEM HEAT PUMPS "ERC" Series Models E*RC018 thru E*RC060 Nominal Capacity: 12 thru 60 MBH Nominal Efficiency: 12 SEER DESCRIPTION The ERC series heat

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR 07.2009 Page: 117 Furnaces 97+% Gas Furnace Acclimate Series LXLP9C060B12MP11 * 97.5% MODULATING 60,000 BTU 1200 CFM MULTI-POSITION GAS FURNACE $3,780.47 LXLP9C080B12MP11 * 97.5% MODULATING 80,000 BTU

More information

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE TEHNIAL UIDE MODELS: M9T-UP AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED ISO 9001 ertified Quality Management System Due to continuous

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500)

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500) TECHNICAL GUIDE STELLAR 2000 TM S: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Nominal Capacity: 18 thru 60 MBH Nominal Efficiency: 10.00 SEER DESCRIPTION The EFD Series heat

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

INSTALLATION MANUAL WARNING STANDARD PSC MODULAR MULTI-POSITION AIR HANDLERS MODELS: MP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION MANUAL WARNING STANDARD PSC MODULAR MULTI-POSITION AIR HANDLERS MODELS: MP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATION MANUAL STANDARD PSC MODULAR MULTI-POSITION AIR HANDLERS MODELS: MP SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant FORM NO. H11-527 REV. 5 Supersedes Form No. H11-527 Rev. 4 AIR HANDLERS (Model with Coil) AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant earth friendly

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 536306-UAI-B-1009 Electric Heat Accessory 10, 16, 20, 26, 32, 36 & 52kW For Split-System R-410A Air Handling Units Both Air Conditioners and Heat Pumps 7-1/2, 10,

More information

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL SPECIFICATIONS B6VMMX TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended

More information

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-509 REV. 8 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate

More information

TECHNICAL GUIDE MODELS: GM9S*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW/HORIZONTAL FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: GM9S*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW/HORIZONTAL FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES TEHNIAL UIDE MODELS: M9S*DH AS-FIED ONDENSIN / HIH EFFIIEN DONFLO/HOIZONTAL FUNAES 92% TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System 278177-BT-A-0407

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RBHP- Series X-13 (ECM) Motor Efficiencies up to 16 SEER Industry Standard R-410A Refrigerant also Suitable for R-22 Applications Models featuring Electric

More information

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES TEHNIAL UIDE Echelon MODELS: F9M*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO MODULATIN FUNAES NATUAL AS 60-0 MBH INPUT EFFIIEN ATIN ETIFIED ISO 900 ertified Quality Management System Due to continuous product

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 5 Ton Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

Variable Speed Convertible Air Handler 2 1/2 Ton

Variable Speed Convertible Air Handler 2 1/2 Ton Submittal Variable Speed Convertible Air Handler 2 1/2 Ton TEM6A0B30H21S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic.

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information