WORK PLAN ULTRASONIC CLEANING USING A HEATED INORGANIC CLEANING FLUID ERIE COUNTY/EPA WRITE PROGRAM. Prepared For:

Size: px
Start display at page:

Download "WORK PLAN ULTRASONIC CLEANING USING A HEATED INORGANIC CLEANING FLUID ERIE COUNTY/EPA WRITE PROGRAM. Prepared For:"

Transcription

1 WORK PLAN ULTRASONIC CLEANING USING A HEATED INORGANIC CLEANING FLUID ERIE COUNTY/EPA WRITE PROGRAM EVALUATION NO. 2 - CONAX BUFFALO CORPORATION Prepared For: Erie County Department of ~nvironment & planning 95 Franklin Street Buffalo, NY Prepared By: Recra Environmental, Inc. 10 Hazelwood Drive, Suite 106 Amherst, NY RE1 Project No. OC2448

2 1.0 INTRODUCTION 1.1 Background Conax Buffalo Corporation (conax) is a medium-sized business located at 2300 Walden Avenue, Buffalo, New York in Erie County. Conax is engaged in the design and manufacture of highlyengineered stainless steel components. Since , halogenated organics and chlorofluorocarbons (CFCs), including trichloroethylene, l,l,l-trichloroethane, trichlorotrifluoroethane (freon) and a freon/acetone mixture have been used at Conax. The CFCs are used for both degreasing parts after machining, and cleaning parts prior to assembly, shipment or stock. Until recently, four operations within Conax utilized CFCs: - Machining centers parts cleaning - Machine shop degreasing - Assembly vapor degreasing - Assembly final cleaning Although the use of CFCs resulted in zxtremely clean parts necessary for passing inspection, there were several disadvantages to their use: o Since freon has such a low boiling point (118O~), fugitive emissions are produced. 0 Fugitive emissions require reporting on IIForm Rff to comply with the Environmental Protection Agency's (EPA's) reporting requirements under SARA Title 111. o The cost of freon was increasing. o CFCs were targeted for eventual elimination due to their ozone depleting characteristics. o The use of CFCs was going to be taxed. o Reclamation of freon was possible, however hazardous wastes were still generated (i.e., F002 stillbottoms). After examining their operations and reviewing the disadvantages to CFC use, Conax decided to investigate alternative cleaning/degreasing processes and cleaning agents. In 1989, Conax initiated the first step in their program to eliminate the use of all CFCs plantwide. Within their machining centers, freon was being used in one and one-half gallon cans for degreasing metal parts. Conax successfully replaced these units with ten-gallon, hot aqueous cleaning systems. These systems,

3 which utilize an alkali (soap) based cleaning agent, have substantially reduced freon usage, fugitive emissions, and hazardous waste generation within Conax. The next step in their CFC elimination program was the removal of CFCs within the machine shop degreasing operation. Conax undertook an intensive investigation into various equipment and processes on the market to replace their 110-gallon freon vapor degreasing unit. Based on their research, Conax decided to replace their existing cleaning unit with a hot aqueous cleaning system utilizing ultrasonics. Conax and Chautauqua Metal Finishing Supply (CMFS), manufacturer of the ultrasonic cleaning system, agreed to participate in the Erie County/EPA WRITE Program in June The ultrasonic cleaning technology purchased by Conax will be the subject of a technical and economical waste reduction evaluation. This system will be compared to Conax, s existing freon vapor degreasing unit employed to clean various stainless steel components. 1.2 objectives Preliminary tests by CMFS on various stainless steel components manufactured by Conax demonstrated the effectiveness of an aqueous ultrasonic cleaning system for cleaning/degreasing. It is the intent of this WRITE Program evaluation to comparatively analyze the economic advantages of employing Conax's ultrasonic cleaning system for reducing both the use and generation of hazardous materials associated with conventional CFC usage. The freon vapor degreasing unit previously employed at the metal shop degreasing operation will be used for a comparison. The objectives of the aqueous ultrasonic cleaning system waste reduction evaluation are as follows: 0 to determine the economics associated with cleaning oil and dirt from stainless steel components using Conaxf s ultrasonic cleaning system employing an inorganic cleaning fluid 0 to determine the use and generation of hazardous materials from Conaxfs ultrasonic cleaning system 0 to evaluate the treatment performance of Conax's aqueous ultrasonic cleaning system in phase separating the surface contamination removed from the stainless steel components

4 1.3 Statement of Work An evaluation of ultrasonic cleaning using a heated inorganic cleaning fluid will be conducted at Conax's Walden Avenue facility to determine the economic benefits and associated waste volume and hazard reduction in comparison to freon vapor degreasing of various stainless steel components. The evaluation will be conducted according to the enclosed work plan. Sampling and analysis of wastes generated from the ultrasonic cleaning unit will be performed in accordance with the Quality Assurance Project Plan (QAPjP) for this evaluation. The results of the evaluation will be assimilated to determine the following: o waste volumes as a function of production/parts processed o presence/absence of pollutants associated with wastes generated o waste volumes using ultrasonic cleaning compared to freon vapor degreasing o economic benefits associated with ultrasonic cleaning o water usage impact using ultrasonic cleaning o labor and operating requirements and expenses associated with ultrasonic cleaning vs freon vapor degreasing A report summarizing the waste reduction evaluation of the ultrasonic cleaning system will be prepared for submission to the EPA. This report will include completed tables as depicted in Appendix A, as well as conclusions regarding the impacts which ultrasonics has on both cleaning/degreasing economics and waste reduction. 2.0 TECHNOLOGY DESCRIPTION 2.1 Aqueous Ultrasonic Cleaning Technology Ultrasonic cleaning is one of a number of methods which can be used for removing microparticulates from hard surfaces. Ultrasonic cleaning consists of immersing a part in a liquid medium, agitating that medium with high frequency (18-20 khz) sound for a brief interval of time (usually a few minutes), rinsing with clean solvent or water, and drying. The underlying mechanism behind this process involves microscopic bubbles in the liquid medium imploding or collapsing under the pressure of agitation, producing shock waves. These shock waves impinge on the surface of the part and, through a scrubbing action, displace or loosen particulate matter from that surface. The process by which these bubbles collapse or implode is known as cavitation.

5 There are no physical means by which actual cavitation action can' be measured. Thus, operators seeking to assess the performance of an ultrasonic cleaning system must rely almost exclusively on the evaluation of actual cleanliness levels achieved. The cavitation intensity in a sonic field is largely determined by three factors: 1. the frequency and amplitude of the radiating wave 2. the colligative properties of the medium (vapor pressure, surface tension, density, viscosity), and 3. the rheological properties of the liquid (static condition, turbulent flow, laminar flow). In order for cavitation to be produced in a liquid medium, the amplitude of the radiating wave must have a certain minimum value, usually rated in terms of electrical input power to the transducer. Cavitation intensity and, hence, cleaning effectiveness is greatly affected by the characteristics of the cleaning fluid. Flow characteristics, or rheological properties, also play an important role in ultrasonic cleaning performance. The design of an ultrasonic cleaning process must take into consideration the size, configuration, and capacity of the ultrasonic tank to accommodate the parts to be cleaned in an efficient manner. Certain basic rules which serve as guidelines in making design-related determinations are as follows: o Tank Loading: The total surface area of the substrate measured in square inches should not be much greater than the tank volume, measured in cubic inches. o Work Baskets and Fixtures: Work baskets or fixtures should have as little mass as possible, be made of metal (preferably stainless steel or some other hard, soundreflecting material), and be of open construction so that there will be minimal interference with the free passage of both sound waves and cleaning fluids. o Work Orientation: Parts to be cleaned should be evenly spaced throughout the tank volume and oriented with their narrowest dimensions toward the transducer radiating surfaces. o Location of Transducers: sonic transducers should be placed on the largest sides or on the bottom of the tank to allow for maximum distribution of sonic energy throughout the cleaning solution.

6 0 Power Requirements: The ultrasonic power requirements, expressed in terms of electrical-input wattage to the transducers, lie in the range of watts per gallon of cleaning fluid, or watts per square inch of transducer radiating surface (for piezoelectric transducers, most commonly used in ultrasonic cleaning systems). o Cleaning Fluid: Cleaning fluids should be carefully selected on the basis of (1) chemical and physical nature of the contaminants to be removed, and (2) identity of the substrate material. The operation of the ultrasonic cleaning system is also critical for the proper removal of particulate matter and other contaminants from substrate surfaces. operating parameters include : 0 Use of clean solvents and detergent solutions: The importance of using clean solvents cannot be overemphasized, since exposure to dirty solutions could easily result in the deposition of soils that are more difficult to remove than the original contaminants. o Wetting of substrates and contaminants: Wetting should usually be accomplished not more than a few seconds following introduction of the sonic fluid. 0 Prevention of redeposition: Continuous filtration or overflow, or both are required to remove contaminants from the cleaning solution so as to prevent redeposition onto the substrate. A flow rate equal to 50% of the liquid volume per minute is the maximum which can be tolerated without loss of cavitation. 0 Disposal or entrapment of contaminants: Substrates must be thoroughly cleaned following each ultrasonic cycle to remove all contaminated cleaning solutions. This can be accomplished through either spraying or vapor misting techniques, or ultrasonic immersion rinsing in heated water in order to maximize cavitation activity. 2.2 Conaxfs Miraclean System The Miraclean System is an ultrasonic cleaning system designed by Chautauqua Metal Finishing Supply (CMFS). It is a modular design of cleaning and rinsing tanks, employing an aqueous cleaning agent within the ultrasonic tank to accelerate the cleaning action (i.e., cavitation). Miraclean Systems have a variety of available options, such as additional rinse tanks and dryer stations, to meet individual customer cleaning requirements.

7 After reviewing Conax's needs for a replacement of their solvent based cleaning system, CMFS suggested their aqueous cleaning system (Miraclean System) as an alternative method of cleaning. To determine the applicability of the system, preliminary trial tests were conducted. Sample tests were run on representative parts sent to CMFS from Conax. The parts were made of stainless steel, aluminum, copper and/or plastic. The parts, designed with internal borings and threads, had color-coded ink markings that had to remain after cleaning. These parts were covered with the typical contaminants that Conax removed, including standard screw machine oils, water-based coolants, and in-house shop dirt. Conax had several criteria for the cleaner to be selected. The cleaner must: o be multi-metal safe o not etch aluminum o be compatible with plastic/nylon o be biodegradable o clean the above contaminants and o be free-rinsing. CMFS used a prototype cleaning system to clean the parts inhouse. After reviewing the criteria for cleaner and the types of contaminants to be removed, a powder silicated cleaner was selected as the best cleaning agent for Conax. Subsequently, the clean parts were sent to Conax for inspection. The cleaned parts met the Quality Department's final inspection product quality standards set by Conax. A second trial run was done with Conax representatives present. A 72" stainless steel pipe was cleaned using the powder silicated cleaner in an ultrasonic cleaning tank. The oils, chips, and dirt particles were removed. conax was satisfied that the Miraclean System would meet their quality standards for the variety of parts they needed cleaned. Based on the results of the preliminary trial tests conducted for Conax, a Miraclean System was designed for their specific requirements. A description of the system, shown schematically in Figure 1, is provided below. Conax's Miraclean System is comprised of (6) six stations: STATION 1: A LOADING STATION where the parts are placed in a basket for cleaning.

8 STATION 2: CLEANING TANK - Six (6) ultrasonic transducers are mounted on the side of the tank. The ultrasonic energy provides a mechanical scrubbing action. This action in conjunction with the cleaning agent quickly and effectively cleans the parts. The cleaning tank is designed with an interior grease trap/overflow weir. A sparger system is used to gently move insoluble oils and surface debris over the grease trap/overflow weir. These oils are contained in this area and are removed via phase separation. A pump and filter system is installed in the cleaning tank to remove suspended solids, chips and files. This extends the life of the cleaning solution. STATIONS 3 & 4: COUNTERFLOW RINSE TANKS - The purpose of a rinse tank is to dilute the concentration of cleaner that remains on the part to a level that is acceptable to Conax. A counterflow rinse system was designed to minimize fresh water use (see diagrams). In a counterflow system, fresh water flows into the third tank. This tank is designed with an overflow weir that empties into the second tank. the second tank has an overflow weir that collects insoluble solution that remains on the part after leaving the cleaning tank. By counterf lowing a single stream of water through two rinse tanks, the same water can be used twice. This greatly reduces the amount of fresh water needed to maintain acceptable rinse dilution. STATION 5: FINAL HOT RINSE - At this time, Conax will use the final tank for rinsing. Heat has been added to this tank to elevate the temperature of the part to help ensure quicker drying. STATION 6: UNLOAD SYSTEM - After leaving the final hot rinse, parts are cooled and removed from the baskets.

9 FIGURE 1 CONAX'S MIRACLEAN SYSTEM SCHEMATIC 'RESH JATER WATER TO DRA IN HOT RINSE COUNTERELOW RTNSE ULTRASONIC CLEAN 180"~ AMB AMB F

10 The dimensions of Conax's Miraclean System are depicted in Figure 2. Overall, the system measures approximately 10' x 6.5' x 3' high. The work area, the area within the system where substrates are ultrasonically cleaned, measures approximately 9' x 1' x 1.5 deep. The system was designed to accommodate Conax's long stainless steel tubes. A plan view of the Conax Miraclean System is shown in Figure 3. This diagram shows the location and relative size of the ultrasonic cleaning equipment, including the transducers, heaters, temperature and other system controls, and the pump and filter system. The heating elements are positioned close to the bottom of the ultrasonic cleaning tank and hot water rinse tank. The six (6) transducers are lined up side-by-side along the largest side of the tank. A cover will be utilized for conservation of energy on the two (2) heated tanks.

11

12

13 3.0 WASTE REDUCTION EVALUATION The evaluation of Conax's Miraclean System on waste reduction will involve several phases. These. include: - obtaining background data on Conaxf s freon vapor degreasing unit - demonstrating the Miraclean System installed at Conax and collecting pertinent operating, performance and waste generation data - assimilating pertinent data from each process and comparing the results Phase I - Obtain Background Data on Conaxfs Freon Vapor Degreasing Unit Historical data regarding the use of Conaxfs freon vapor degreasing unit shall be obtained. This data shall include, but is not limited to: o Process Information - operation type - unit size, dimensions - throughput - operating procedures and costs - waste generation o Raw Material Use - freon use (type, consumption rate) - inventory data (delivery mode, transfer mode, container management) - cost of raw materials (purchase price, taxes, etc.) o Waste Generation Data - waste types and characteristics - generation rates (also as a function of production) - waste management practices - costs associated with waste generation The above information will be gathered from existing records at the Conax facility. Where pertinent data is not readily available, Conax will assist us in developing alternative data based on reasonable assumptions. Phase I1 - Demonstrate Miraclean System Installed at Conax and Collect Data The Miraclean System installed at Conax shall be operated and monitored for a one (1) month period to obtain pertinent data necessary for the waste reduction evaluation.

14 Log sheets operating sheets wi Department and Method will be available near the operation for recording key parameters during the demonstration period. These log 11 be maintained by the Machine Shop Degreasing Supervisor and reviewed by Conax's Facilities Engineer Proj ect Manager. Cleaning cycles shall be performed according to the Standard Operating Procedures (SOPS) for the System included for reference in Appendix B. For each cleaning cycle, the following information shall be recorded: Station 1 - Loadins Station - start time - types of parts to be cleaned, including parts description - approximate number of parts to be cleaned Station 2 - Ultrasonic Cleaninq Tank - start time - ph of tank - temperature of cleaning solution - stop time Station 3 - Counterflow Rinse Tank - start time - temperature of water - ph of water - flow rate of water - stop time Station 4 - Counterflow Rinse Tank - start time - temperature of water - ph of water - stop time Station 5 - Final Hot Rinse Tank - start time - temperature of water - stop time Station 6 - Unloadinq Station (Coolinq) - stop time

15 On a daily basis, additional data shall be recorded: - hours of steady state operation - weight of filters (when changed) - make-up added to cleaning tank (if any) - cleaning solution waste generated (if any) - oil quantities removed from cleaning tank overflow weir (if any) A sample Cleaning Cycle Log Sheet for recording data is included in Appendix C. Daily information regarding the system demonstration will be recorded on a Daily Log Sheet, shown in Appendix D. Erie County and/or Recra Environmental personnel will periodically observe the on-site demonstration of the Conax Miraclean System. From these observations, additional data which will be factored into the waste reduction evaluation shall be obtained. This data includes, but is not limited to: - system requirements (utilities, labor) during steady state (non-cleaning cycles) - maintenance requirements (supplies, labor) - production/work flow impacts - product quality influence - storage requirements (raw materials, products) - training requirements/system simplicity - system performance/reliability Product Quality Standards for parts cleanliness set by Conax will be maintained throughout the waste reduction evaluation. These standards are qualitative, not quantitative, and thus cannot be measured analytically. This WRITE Program evaluation will therefore depend on Conax personnel for their qualitative measurement of product cleanliness. A verbal description of this measurement is included in Appendix E. All wastes generated from the Ultrasonic Cleaning System are anticipated to be non-hazardous materials, based on the MSDSs for the coolant and cutting oils used for machining, and on the MSDS for the silicate cleaner. However, in order to evaluate the performance of the cleaning system in phase separation of the contaminants removed from the stainless steel components, various samples are required. Therefore, a sampling and analysis program will be conducted on the nonhazardous waste concentrate, waste oil and wastewater from the Ultrasonic Cleaning System. This analysis will focus on two distinct parameters; oil and grease, and TOC (Total Organic Carbon) for determination of the potential presence/absence of priority vs non-priority pollutants in these waste materials. Samples of the wastes will be collected and analyzed according to the QAPjP prepared for this evaluation. As indicated on the Cleaning Cycle Log Sheet, the ph of the various liquids will be measured throughout the evaluation.

16 Phase I11 - Assimilation 05 Data for cleaning Process Comparison Data obtained within Phase I and phase I1 of the waste reduction evaluation of Conaxfs Miraclean System shall be assimilated as Phase 111. Data assimilation will include calculations for each cleaning process relative to: - total operating costs and labor requirements (hours and costs) - raw material consumption and cost - utilities use and cost - maintenance requirements (labor hours, supplies and costs) - production throughput (annual and costs basis) - waste generation quantities - waste transportation and disposal costs Conax will supply all necessary cost data relative to the purchase and installation of the Miraclean System (purchased equipment, utility connections, ancillary equipment, start-up, etc.). This information will be reported for the reader's knowledge. 4.0 EVALUATION SUMMARY AND CONCLUSIONS The results of the waste reduction evaluation of Conax's Miraclean System will be summarized for comparison with the use of the freon vapor degreasing process. Among others, the following results will be documented: o raw material costs per part cleaned o operating costs per part cleaned o waste generation per part cleaned o waste disposal costs per part cleaned Final results will be presented in tabular form, according to the tables included included in Appendix A. 5.0 PREPARATION OF REPORT A report shall be prepared after the evaluation of Conax's Miraclean System has been completed. This report shall include the findings and conclusions of the evaluation, according to the outline presented in Appendix F. The completed tables identified in Section 4.0 will be included in the final report. 6.0 PROJECT SCHEDULE The anticipated schedule for completing the tasks in the work plan is presented in Figure 4.

17

18 APPENDIX A ULTRASONIC CLEANING SYSTEM EVALUATION FINAL REPORT TABLES

19 SUMMARY OF DESIGN AND OPERATING CHARACTERISTICS FOR CLEANING TECHNOLOGIES CHARACTERISTIC System Capacity (units per hour) FREON VAPOR DEGREAS ER AQUEOUS ULTRASONIC CLEANING SYSTEM System Mobility (transportable, fixed) ~ogistical Operating Requirements: 2 Space (area) (ft. ) Water (gals. per hr.) Electrical Power (amps) (volts) Sewage Access (yes/no) Labor Requirements (man hours/cleaning cycle)

20 SUMMARY OF RAW MATERIALS USE FOR CLEANING TECHNOLOGIES FREON VAPOR DEGREASER AQUEOUS ULTRASONIC CLEANING SYSTEM Raw Material Used: Product Type Usage Rate (lb./year) Delivery Mode Transfer Mode Empty Container Management Raw Material Cost: Purchase Price ($/lb.) Taxes (if applicable, $/lb.) Total Cost ($/lb. ) Storage Reqyirements: Area (ft. ) Special Precautions

21 SUMMARY OF OPERATING PROCEDURES AND COSTS FOR CLEANING TECHNOLOGIES FREON VAPOR DEGREASER AQUEOUS ULTRASONIC CLEANING SYSTEM Avg. Length of Cleaning Cycle (min/cycle) Avg. No. of Cleaning Cycles per Year (#/yr) Avg. No. of Parts per Cleaning Cycle (parts/cycle) Utility Requirements: Energy (KWH/yr. ) Water (gal./yr. ) Labor Requirements: System Operation (man hours/yr.) Maintenance (man hours/yr. ) Raw Material Usage: Freon (lb./yr.) Silicate Cleaner (lb../yr.) Operating Costs: utility Costs ($/yr. ) La.bor Costs ($/yr. ) Raw Material Costs ($/yr.) Total Operating Costs ($/yr.)

22 SUMMARY OF WASTE GENERATION FOR CLEANING TECHNOLOGIES FREON VAPOR DEGREASER AQUEOUS ULTRASONIC CLEANING SYSTEM Waste Type/Quantity (lb./yr. ) : Hazardous: Freon Non-Hazardous: Concentrated Cleaner Rinse Water Cooling Water Oil Filters Air Emissions: vocs Total Waste Quantity (lb./yr.) Mgmt. Practice Cost Mgmt. practice cost Waste Management Practice/Cost ($/yr-): Freon Concentrated Cleaner Rinse Water Cooling Water Oil Filters vocs Total Waste Management Cost ($/Year)

23 SUMMARY OF CLEANING TECHNOLOGY EVALUATION Raw Material Cost per Part Cleaned ($/part) operating Cost per Part Cleaned ($/part) Waste en era ti on per Part Cleaned (lb./part) - total - hazardous - vocs Waste Disposal Cost per Part Cleaned ($/part) FREON VAPOR DEGREASER AQUEOUS ULTRASONIC CLEANING SYSTEM REDUCTION

24 APPENDIX B ULTRASONIC CLEANING SYSTEM EVALUATION STANDARD OPERATING PROCEDURES FOR CONAX'S MIRACLEAN SYSTEM

25 APPENDIX C ULTRASONIC CLEANING SYSTEM EVALUATION CLEANING DEMONSTRATION LOG SHEET

26 ULTRASONIC CLEANING SYSTEM EVALUATION CLEANING DEMONSTRATION LOG SHEET Date : Operator: STATION 1 - LOADING STATION Start time: ~escription No. of parts to be cleaned: 1-15 (diameter, length, material type) : Parts Configuration: tubes other STATION 2 - ULTRASONIC CLEANING TANK Start time: Stop time: Elapsed time: 0 ph: - Temperature ( F) : Flow Rate (gpm) : STATION 3 - COUNTERFLOW RINSE TANK NO. 2 Start time: Stop time: Elapsed time: 0 ph: - Temperature ( F) : STATION 4 - COUNTERFLOW RINSE TANK NO. 1 Start time: Stop time: Elapsed time: ph: - Temperature (OF) : STATION 5 - FINAL HOT RINSE TANK Start time: Stop time: Elapsed time: Temperature (OF) : STATION 6 - UNLOADING STATION (COOLING) Stop time: Inspection: - Clean - Not Clean - Return to Station 1

27 APPENDIX D ULTRASONIC CLEANING SYSTEM EVALUATION CLEANING DEMONSTRAITON DAILY LOG SHEET

28 ULTRASONIC CLEANING SYSTEM EVALUATION CLEANING DEMONSTRATION DAILY LOG SHEET Day Hours of Steady State Operat ion Make-up Added (gal) Water Cleaner W A S T E Oil from Cleaning Tank Weir G E N E R A T I O N (lb) Filter from Cleaning Cleaning Tank Waste Tank Recycle Solution

29 APPENDIX E PRODUCT QUALITY STANDARDS

30 PRODUCT QUALITY STANDARDS Final Inspection: Products which have been cleaned using either the Freon Vapor Degreasing Unit or Aqueous ultrasonic cleaning System are visually inspected in the Quality Department's Final Inspection area. Cleaned parts may contain no visual residues or white powder in order to pass inspection. They must be completely dry. Parts which do not pass final quality inspection must be returned to the finishing department and be re-cleaned.

31 APPENDIX G OUTLINE WASTE REDUCTION EVALUATION REPORT EXECUTIVE SUMMARY I. Introduction 11. Technology Description 111. Description of Technical and ~conomic valuation IV. sampling and Analysis Plan V. Data Summary and Analysis A. Historical Data on Facility B. Operating Data Summary C. Performance and Analytical Results D. Economic Evaluation VI. Evaluation Summary and Conclusions Appendix: Quality Assurance and Quality Control Procedures and Results

PARTS CLEANING AND DEGREASING

PARTS CLEANING AND DEGREASING Important Note: The following text is excerpted directly from the New York State Department of Environmental Conservation s publication, Environmental Compliance, Pollution Prevention, and Self Assessment

More information

associates Precision Cleaning Systems 3678 Bassett St., Santa Clara CA Phn: [ 408 ] Fax: [ 408 ]

associates Precision Cleaning Systems 3678 Bassett St., Santa Clara CA Phn: [ 408 ] Fax: [ 408 ] associates Precision Cleaning Systems www.tmasc.com 3678 Bassett St., Santa Clara CA 95054 Phn: [ 408 ] 727 8388 Fax: [ 408 ] 727 8997 E-Mail tony@tmasc.com Designing an Ultrasonic cleaning System Equipment

More information

CAV-METER ULTRASONIC CAVITATION INTENSITY METER

CAV-METER ULTRASONIC CAVITATION INTENSITY METER INSTRUCTION MANUAL FOR CAV-METER ULTRASONIC CAVITATION INTENSITY METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com

More information

Is Your Ultrasonic Cleaning System Living Up to Its Potential?

Is Your Ultrasonic Cleaning System Living Up to Its Potential? Is Your Ultrasonic Cleaning System Living Up to Its Potential? Some guidelines about ultrasonic cleaning equipment and performance. The use of ultrasonic cleaning equipment to clean or degrease parts has

More information

BHC. Replacing Air Sparging Agitation Increases Cleaning Efficiency in Immersion/Soak Tank Degreasing BHC WHITE PAPER

BHC. Replacing Air Sparging Agitation Increases Cleaning Efficiency in Immersion/Soak Tank Degreasing BHC WHITE PAPER WHITE PAPER Replacing Air Sparging Agitation Increases Cleaning Efficiency in Immersion/Soak Tank Degreasing Progressively tighter cleanliness specifications of high-precision manufactured parts require

More information

Application Data Sheet

Application Data Sheet Application Data Sheet Chemical Cleaning after Thinning, Backside Grinding, Lapping, or Polishing of Silicon or Gallium Nitride Substrates Wafer cleaning after thinning, backside grinding, polishing, or

More information

Theory of Operation: How Parts Cleaning Works

Theory of Operation: How Parts Cleaning Works Theory of Operation: How Parts Cleaning Works MART defines the term to clean as to overpower the soils. The MART Parts Washer is a high-impact pressure, high-temperature, industrial water-based cleaning

More information

Metal Finishing Workshop March 4, 2010

Metal Finishing Workshop March 4, 2010 Metal Finishing Workshop March 4, 2010 Hosted by: New York State Pollution Prevention Institute at Rochester Institute of Technology 2010 New York State Pollution Prevention Institute. All rights reserved

More information

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations WHITE PAPER The Importance of Rinsing in Metal Finishing Operations By Steve Rudy, CEF & Sales/Technical Representative The focus or driving force of rinsing is to eliminate contaminants from the surface.

More information

Rotary Impingement Tank Cleaning Equals Significant Water and Cost Savings

Rotary Impingement Tank Cleaning Equals Significant Water and Cost Savings Rotary Impingement Tank Cleaning Equals Significant Water and Cost Savings Specific information and case studies on the benefits of rotary impingement and cleanin-place (CIP) optimization vs. the standard

More information

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Before digging into the 10 things you should know let s start with a brief explanation of the process. Ultrasonic cleaners are unsurpassed when it comes to removing contaminants from virtually any hard surface that can be safely immersed in a cleaning solution. The challenge is selecting the correct ultrasonic

More information

Aqueous Cleaning Design Considerations --us-

Aqueous Cleaning Design Considerations --us- Aqueous Cleaning Design Considerations --us- Peter F. Maltby, Vice President of Engineering, Crest Ultrasonics Corporation INTRODUCTION The phase-out of CFCs and other ozone depleting chemicals has prompted

More information

Precision Ultrasonic Cleaning Equipment Buyers Guide

Precision Ultrasonic Cleaning Equipment Buyers Guide Precision Ultrasonic Cleaning Equipment Buyers Guide Contents Introduction... 3 Size... 3 Tank Specification... 3 Control... 4 Transducer Efficiency... 4 Ultrasonic Power... 4 Timer... 5 Basket... 5 Lid...

More information

Cost, time and water savings gained through optimized tank cleaning

Cost, time and water savings gained through optimized tank cleaning Cost, time and water savings gained through optimized tank cleaning Abstract: Specific case studies on the benefits of rotary impingement and CIP optimization vs. the standard tank cleaning processes.

More information

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L 1 2 Ideal for cleaning surgical, medical, dental instruments and equipment. Available in various sizes. Before placing instruments into the Ultrasonic Cleaner a degas cycle should be run. Then a clinical

More information

DRAFT. Electroplating Tip Sheet Drag-Out Reduction. Background

DRAFT. Electroplating Tip Sheet Drag-Out Reduction. Background Electroplating Tip Sheet Drag-Out Reduction Electroplating Tip Sheet Series 1. Good Operating Practices 2. Drag-Out Reduction 3. Rinse Water Reduction 4. Recovery and Recycling of Bath Chemicals Background

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY natoli.com PROPER TOOL CLEANING IS CRUCIAL EXTEND TOOL LIFE DECREASE PRESS DOWNTIME REDUCE PRODUCTION-RELATED COSTS IMPROVE TABLET QUALITY Tablet

More information

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaners Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION CFSA CSSD Conference Durban ICC Wednesday 8 th March 2017 Using technology to improve patient safety THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION Helen Loudon Independent Infection

More information

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs) State of New Jersey Department of Environmental Protection Air Quality Permitting for Non-HAP Volatile Organic Compounds (VOCs) This General permit allows for the construction, installation, reconstruction,

More information

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine: OPERATIONAL & INSTRUCTION MANUAL Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine: L1 to L2: L1 to Ground: L2 to Ground UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255

More information

Ontario Region POLLUTION PREVENTION FACT SHEET. Pollution Prevention Program - Federal Programs Division

Ontario Region POLLUTION PREVENTION FACT SHEET. Pollution Prevention Program - Federal Programs Division Ontario Region Environmental Protection Branch POLLUTION PREVENTION FACT SHEET Pollution Prevention Program - Federal Programs Division Fact Sheet #13: Pollution Prevention for Cleaning and Degreasing

More information

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaners Cavitator Ultrasonic Cleaners Instruction Manual 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com email:

More information

obtained frm- implementation of alternative, cost-effective cleaning technologies.

obtained frm- implementation of alternative, cost-effective cleaning technologies. complexity of the parts, as well as their critical tolerances. In many rebuilding facilities, transmissions are cleaned in aqueous spray washers followed by manual scrubbing in a solvent tank. The latter

More information

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) OPERATIONAL & INSTRUCTION MANUAL Model: 2400FA (120v 1Ø) UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255 Tel: 513-502-9746 Fax: 513-702-2399 info@ultrasonicllc.com www.ultrasonicllc.com SAFETY REQUIREMENTS

More information

Batch Semi-Aqueous Emulsion Cleaning by

Batch Semi-Aqueous Emulsion Cleaning by Batch Semi-Aqueous Emulsion Cleaning by Rex Breunsbach Electronic Controls Design Inc. Milwaukie, Oregon Abstract Recent development and work with water immiscible Semi-Aqueous solvents at 5%-20% concentration

More information

Whittemore Ultrasonic Cleaner

Whittemore Ultrasonic Cleaner Whittemore Ultrasonic Cleaner Tank Capacity Heating Power Ultrasonic Power Time Setting Temperature Setting 1.3L 50W 60W 1-30 minutes 0-80 degrees Celsius 2L 50W 60W 1-30 minutes 0-80 degrees Celsius 6L

More information

Cavitator Ultrasonic Cleaner Instruction Manual

Cavitator Ultrasonic Cleaner Instruction Manual Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

Airless Vacuum Cleaning Systems

Airless Vacuum Cleaning Systems Airless Vacuum Cleaning Systems 1 Serec Airless Vacuum Cleaning Systems Serec Airless Cleaning Systems are distillable solvent cleaning systems where the process occurs in a vacuum chamber for the ultimate

More information

Thomas J.M. Weaver PresidentlCEO PROSYS Corporation

Thomas J.M. Weaver PresidentlCEO PROSYS Corporation RECYCLING AND RECOVERY OF CLEJWING SOLUTIONS Thomas J.M. Weaver PresidentlCEO PROSYS Corporation ABSTRACT : The proper cleaning of components in the metal finishing industry is the key to quality in the

More information

PRETREATMENT SYSTEMS. For Metal Cleaning, Washing and Recovery FOR PAINT, POWDER, E-COATING AND PLATING OPERATION CUSTOM CONFIGURATIONS UP TO 7 STAGES

PRETREATMENT SYSTEMS. For Metal Cleaning, Washing and Recovery FOR PAINT, POWDER, E-COATING AND PLATING OPERATION CUSTOM CONFIGURATIONS UP TO 7 STAGES PRETREATMENT SYSTEMS For Metal Cleaning, Washing and Recovery FOR PAINT, POWDER, E-COATING AND PLATING OPERATION RECYCLE UP TO 100% OF YOUR CLEANING SOLUTIONS CUSTOM CONFIGURATIONS UP TO 7 STAGES USE YOUR

More information

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

For inspection purposes only.

For inspection purposes only. Attachment F.1 Neutralisation System Process Description The CPG process generates both acid and caustic waste water from the acid/base leaching processes. This waste water will be collected in dedicated

More information

Water Efficiency. Industry Specific Processes. Metal Finishing. for Commercial, Industrial and Institutional Facilities

Water Efficiency. Industry Specific Processes. Metal Finishing. for Commercial, Industrial and Institutional Facilities Water Efficiency Industry Specific Processes Metal Finishing for Commercial, Industrial and Institutional Facilities During the past 15 years, the metal finishing industry has made great strides in reducing

More information

Fact Sheet. Recovery of Steam Condensate Utilizing Membrane Technology at Carlisle SynTec Inc., Greenville, Illinois

Fact Sheet. Recovery of Steam Condensate Utilizing Membrane Technology at Carlisle SynTec Inc., Greenville, Illinois ISTC Fact Sheet TN10-096 November 2009 Recovery of Steam Condensate Utilizing Membrane Technology at Carlisle SynTec Inc., Greenville, Illinois The Challenge Carlisle SynTec manufactures single-ply roofing

More information

1. Cleaning Technology. o 1.1 Power o 1.2 Grit o 1.3 Temperature o 1.4 Chemical o 1.5 Time. 2. Chemical-Concentration Management

1. Cleaning Technology. o 1.1 Power o 1.2 Grit o 1.3 Temperature o 1.4 Chemical o 1.5 Time. 2. Chemical-Concentration Management 1. Cleaning Technology o 1.1 Power o 1.2 Grit o 1.3 Temperature o 1.4 Chemical o 1.5 Time 2. Chemical-Concentration Management o 2.1 Chemical: General o 2.2 Selecting the Right Chemical o 2.3 Selecting

More information

What cannot be cleaned in a stencil cleaner? Prepared by Steve Stach

What cannot be cleaned in a stencil cleaner? Prepared by Steve Stach What cannot be cleaned in a stencil cleaner? Prepared by Steve Stach The stencil cleaner can be one of the most versatile tools on the manufacturing floor. It can be used to clean electronic modules in

More information

Innovative Cleaning Technology

Innovative Cleaning Technology Selection Guide Innovative Cleaning Technology Spray Wash s Ultrasonic s Vibratory s Immersion s Acid s Floor s Maintenance s Machine Tool s Solvent s An ISO 9001:2008 COmpAny QualiChem 2003 Salem Industrial

More information

CATALOG 100 MIGI KLEEN

CATALOG 100 MIGI KLEEN CATALOG 100 MIGI KLEEN Modern Parts Washing Systems Health, safety and environmental regulations are redefining the workplace. It's a sign of the times and a signal to all progressive thinking manufacturer's

More information

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning Presenter: Malcolm McLaughlin Date: 04/04/2019 A Review of Medical Device and Optical Critical Cleaning Introduction Malcolm McLaughlin VP, Product & Business Development 30+ years detergent formulation,

More information

All Cleaning Options for Parts Cleaning

All Cleaning Options for Parts Cleaning All Cleaning Options for Parts Cleaning Rick Perkins Chemical Engineer / President Chem Logic Austin, Texas www.chemlogic.us 512-426-5728 rperkins@chemlogic.us Our Experience 10 years in M&P working on

More information

Cleaning Today s Assemblies in Batch Systems

Cleaning Today s Assemblies in Batch Systems Cleaning Today s Assemblies in Batch Systems Jay Soma, Jeffrey Dunlap, Robert Sell, Bill Breault and Christine Fouts Petroferm Inc. Gurnee, IL ABSTRACT Batch cleaning of electronic assemblies is popular

More information

Hybrid Refrigerated/Desiccant Compressed Air Dryers

Hybrid Refrigerated/Desiccant Compressed Air Dryers Hybrid Refrigerated/Desiccant Compressed Air Dryers This paper first appeared at the 2013 World Energy Engineering Congress Wayne Perry, Senior Technical Director David Phillips, Air Treatment Product

More information

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255 OPERATIONAL & INSTRUCTION MANUAL Models: 1000M, 1300M, 2000M and 2100M (120v) UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255 Tel: 513-502-9746 Fax: 513-702-2399 info@ultrasonicllc.com www.ultrasonicllc.com

More information

ADVANCE VAPOR DEGREASING OF HIGH RELIABILITY PRINTED CIRCUIT BOARD ASSEMBLIES BY Richard D. Jackson

ADVANCE VAPOR DEGREASING OF HIGH RELIABILITY PRINTED CIRCUIT BOARD ASSEMBLIES BY Richard D. Jackson ADVANCE VAPOR DEGREASING OF HIGH RELIABILITY PRINTED CIRCUIT BOARD ASSEMBLIES BY Richard D. Jackson I. Purpose of Paper The purpose of this paper is to provide information concerning the cleaning of ionic

More information

Reduce Energy Costs with Vapor Degreasing. Mike Jones MicroCare Corp., New Britain, CT

Reduce Energy Costs with Vapor Degreasing. Mike Jones MicroCare Corp., New Britain, CT Reduce Energy Costs with Vapor Degreasing Mike Jones MicroCare Corp., New Britain, CT In the product finishing world, there are four common precision cleaning processes: hydrocarbon, aqueous, semi-aqueous,

More information

PURPOSE OF THE PROCEDURE

PURPOSE OF THE PROCEDURE Title: Procedures for Ozone Depleting Substances Effective Date: November 2005 Issuing Authority: Responsible Officer: VP, Capital Projects & Facilities Director Environmental Health and Safety PURPOSE

More information

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This section outlines the requirements for the nitrogen-generating sprinkler corrosion inhibiting system. The work

More information

Installation Instructions U-RAD-LT Electric Radiant Heaters

Installation Instructions U-RAD-LT Electric Radiant Heaters Installation Instructions U-RAD-LT Electric Radiant Heaters 1 PG421-2 161-058006-001 May 2016 2 U-RAD-LT Electric Radiant Heaters The Safety Alert Symbol is used to indicate a risk of personal injury.

More information

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia VAPOUR RECOVERY DURING FUEL LOADING Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia ben_adamson@refeng.com.au ABSTRACT Volatile fuels such as gasoline and naphtha, and to

More information

Ammonia. Background on ammonia as a refrigerant

Ammonia. Background on ammonia as a refrigerant Ammonia Danfoss Industrial refrigeration has written a technical paper on things to consider when changing from HFC/HCFC s to ammonia. It outlines some of the main differences between the different plant

More information

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT 1. Version, Date. 3, 07 Sep 2014 (EMS) 2. Purpose. This Environmental Standard Operating Procedure (ESOP) establishes general use procedures

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

Selecting Cleaning Processes for Electronics Defluxing: Total Cost of Ownership

Selecting Cleaning Processes for Electronics Defluxing: Total Cost of Ownership Selecting Cleaning Processes for Electronics Defluxing: Total Cost of Ownership Michael C. Savidakis, Ph.D., Jay Soma, Ph.D., Robert Sell, and Christine Fouts, Ph.D. Petroferm Inc. Gurnee, Illinois Abstract

More information

Opteon Vertrel. Specialty Fluids by The Chemours Company. Innovative Fluids That Deliver Superior Performance

Opteon Vertrel. Specialty Fluids by The Chemours Company. Innovative Fluids That Deliver Superior Performance Opteon Vertrel by The Chemours Company Innovative Fluids That Deliver Superior Performance Chemours is a dynamic science company with a strong commitment to protecting the environment. Because of that

More information

KOCH Curtain Coaters

KOCH Curtain Coaters KOCH Curtain Coaters George Koch Sons has installed 700+ Curtain Coaters in the past 40 years. The two types of coaters can be classified into the following categories: 1. KOCH Pressure Head Curtain Coater:

More information

Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner

Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner Dave Kelso Senior Account Manager DuBois Chemical (david.kelso@duboischemicals.com) John Schwamberger Paper Chemicals Division

More information

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS 1.0 General Page 01 2.0 Description 01 3.0 Set-Up 01 4.0 Model 5462 03 4.2

More information

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE. DFE T ECHNOLOGY As components become smaller, component mixes become more diverse, and board densities continue to increase, the processes of packaging, interconnection, and assembly are challenging the

More information

STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES

STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES 1.0 INTRODUCTION STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES This Standard Operating Procedure (SOP) was prepared to direct field personnel in the methods for decontamination of field

More information

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles. 35 Evaporation of waste wash water occurs during normal operation of the pressure, steam or automatic vehicle wash system. It is generally assumed that 10-30% of wash water is lost to evaporation. Accelerated

More information

The cutting-edge in green industrial parts washing technology

The cutting-edge in green industrial parts washing technology The cutting-edge in green industrial parts washing technology What does a Bio-Circle Industrial Parts Washing System consist of? 1 2 3 Cleaning Liquid (bio-remediating) Industrial parts washer Maintenance

More information

EXTREME HC-4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT Tel:

EXTREME HC-4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT Tel: [Type a quote from the document or the summary of an interesting point. You can position the text box anywhere in the document. Use the Drawing Tools tab to change the formatting of the pull quote text

More information

The cutting-edge in environmentallyconscious industrial parts washing

The cutting-edge in environmentallyconscious industrial parts washing The cutting-edge in environmentallyconscious industrial parts washing Your safest, most efficient alternative to toxic solvent parts washing The BIO-CIRCLE parts cleaning system is a safe, efficient and

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business Coal Handling and Processing Advanced Solutions for Coal-Related Environmental Dust Control Better Air is Our Business Coal Handling and Processing Industry Leader Our Qualifications For more than 85 years,

More information

Operating Instructions

Operating Instructions Operating Instructions Modular Cleaning System SW60 / 150 / 240 MOD english Sonoswiss G _Modulrange_SW60/150/240_Sonoswiss_E_08.2012 Contents Contents... 1 1 General... 2 2 Important safety warnings...

More information

Pretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc.

Pretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc. Pretreatment Processes for the Aluminum Extrusion Industry Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc. Purpose of Pretreatment Process Clean/etch, condition and treat

More information

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 23 WEAPONS CLEANING

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 23 WEAPONS CLEANING ENVIRONMENTAL STANDARD OPERATING PROCEDURE 23 WEAPONS CLEANING 1. Version, Date. 1, 6 June 2012 2. Purpose. This Environmental Standard Operating Procedure (ESOP) summarizes the procedures implemented

More information

Omegasonics. Ultrasonic Cleaning Equipment Operation & Instruction Manual

Omegasonics. Ultrasonic Cleaning Equipment Operation & Instruction Manual Omegasonics Ultrasonic Cleaning Equipment Operation & Instruction Manual OMEGASONICS Table Top Unit 2017 and After Model 7850TT / 7950TT Read all instructions thoroughly before operating this equipment

More information

RTS SERIES RIVEER TREATMENT SYSTEMS. The Solution is Clear with Riveer SM. Engineered Wash Water Recovery Systems

RTS SERIES RIVEER TREATMENT SYSTEMS. The Solution is Clear with Riveer SM. Engineered Wash Water Recovery Systems RTS SERIES RIVEER TREATMENT SYSTEMS The Solution is Clear with Riveer SM Engineered Wash Water Recovery Systems RTS SERIES Riveer Treatment Systems WORLD CLASS WATER TREATMENT AND RECYCLING The RTS Series

More information

EXTREME HC-2 Reverse Osmosis System

EXTREME HC-2 Reverse Osmosis System EXTREME HC-2 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com Contents INTRODUCTION... 3 THEORY OF OPERATION... 4 Terms...

More information

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries Instructions for Ultrasonic Washer E397 & E397RC E498 & E498RC 1. INTRODUCTION The E397 and E498 units automatically perform a cleaning cycle, the major steps of which are: Ultrasonic Cleaning Ultrasonic

More information

AGC Sputter Coating Glass Processing Guidelines

AGC Sputter Coating Glass Processing Guidelines TECHNICAL SERVICES DOCUMENT TSD-217 AGC Sputter Coating Glass Processing Guidelines Introduction Comfort Select and Energy Select are Low-Emissivity glasses manufactured by AGC Glass Company North America.

More information

Cleaning systems Overview

Cleaning systems Overview . Cleaning systems Cleaning systems Overview 424 Ultrasonic cleaning units 434 Cleaning products for ultrasonic cleaners 422 Tel. +49 (0) 22 04 / 8 39-0 Fax +49 (0) 22 04 / 8 39-1 info@joke.de . Cleaning

More information

Guidance Document for the Halogenated Solvent Cleaner NESHAP - Forms Only Version

Guidance Document for the Halogenated Solvent Cleaner NESHAP - Forms Only Version EPA-453/R-94-081 Guidance Document for the Halogenated Solvent Cleaner NESHAP - Forms Only Version Sponsored by: Emission Standards Division Office of Air Quality Planning and Standards U. S. Environmental

More information

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 - PROMOSOLV TM 71DS1 FEATURES Water removal at the final step of production, is one of the most important step in the manufacturing of mechanical assemblies, plastic and electronic parts. The spot free drying

More information

OWEA Biosolids Specialty Workshop December 3, 2015

OWEA Biosolids Specialty Workshop December 3, 2015 Operation, Performance, Optimization, Advantages & Disadvantages OWEA Biosolids Specialty Workshop December 3, 2015 Dan Fronhofer, P.E. BDP Industries Recessed Chamber Press Plate & Frame Centrifuge Belt

More information

EXTREME HC-8 Reverse Osmosis System

EXTREME HC-8 Reverse Osmosis System EXTREME HC-8 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION...

More information

Small Business Assistance Program Metal Finishers Compliance Checklist

Small Business Assistance Program Metal Finishers Compliance Checklist Small Business Assistance Program Metal Finishers Compliance Checklist 1 Company Information Business Representative Present for Assessment: Date: Company Name: Physical Address: City: Mailing Address:

More information

Annual Tune-Up Procedure

Annual Tune-Up Procedure Annual Tune-Up Procedure SOLVENT SAVER RECYCLER MODELS SC (9711) AND HC (9725) 1 TABLE OF CONTENTS PAGE SPECIFICATIONS... 3 SAFETY & WARNINGS... 4-6 OVERVIEW... 7 CLEANING THE BOILER... 8-9 CHANGING THE

More information

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was Heat Exchangers vs. Air Conditioning: The Optimal Choice for Cooling Electronics Written by Kimberley Dawn, chief executive officer, Noren Products Exclusively for Process Cooling Submitted by Trade Press

More information

Serec Corporation. American owned company located in Rhode Island, with a 30,000 square foot facility.

Serec Corporation. American owned company located in Rhode Island, with a 30,000 square foot facility. Overview Serec Corporation American owned company located in Rhode Island, with a 30,000 square foot facility. We manufacture standard and custom designed part cleaning machines to support all manufacturing

More information

Consumer Decision Making Contest Study Guide Laundry Detergent

Consumer Decision Making Contest Study Guide Laundry Detergent Consumer Decision Making Contest 2001-2002 Study Guide Laundry Detergent Perhaps you remember the song you sang as a child: This is the way we wash our clothes, we wash our clothes, we wash our clothes.

More information

UNSIGNED HARDCOPY NOT CONTROLLED

UNSIGNED HARDCOPY NOT CONTROLLED Subject: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS REFERENCES Optics Manager, Hardware Engineering Maintenance Revision Defines and specifies the mandatory techniques to be used in the handling and

More information

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP) INDUSTRIAL - SOLVENT PARTS CLEANER OPERATION & INSTRUCTION MANUAL I. Introduction A. Manufacturer s Statement CM200 (115V OR 230V PUMP) This manual will provide you with important information about the

More information

Griffin 824 Operational Suitability: Evaluation of Clear-Down Time for Mass Spectrometry- Based Trace Detector WHITE PAPER. Philip J. Tackett, Ph.D.

Griffin 824 Operational Suitability: Evaluation of Clear-Down Time for Mass Spectrometry- Based Trace Detector WHITE PAPER. Philip J. Tackett, Ph.D. WHITE PAPER Griffin 824 Operational Suitability: Evaluation of Clear-Down Time for Mass Spectrometry- Based Trace Detector INTRODUCTION Philip J. Tackett, Ph.D. 1 SYNOPSIS The following white paper describes

More information

Operating Instructions

Operating Instructions Operating Instructions Ultrasonic Cleaning Units Transsonic TI-H english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-germany.com www.elma-germany.com

More information

Heat sinks for electronic cooling applications

Heat sinks for electronic cooling applications Heat sinks for electronic cooling applications Shubhash V. Jadhav Department of Mechanical Engineering, SVERI s College of Engineering Pandharpur, Introduction The previous century brought the miniaturization

More information

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System This document contains Instructions for Use regarding the processing of the SterilContainer S prior to sterilization

More information

FALLING FILM CHILLERS

FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Paul Mueller Company s Other applications include

More information

Rutgers Environmental Health and Safety (REHS)

Rutgers Environmental Health and Safety (REHS) Rutgers Environmental Health and Safety (REHS) Program Name: Laboratory Laser Safety Program Responsible Executive: Executive Director of REHS Adopted: February 20, 2001 Reviewed/Revised: July 10, 2018

More information

OPERATION INSTRUCTION

OPERATION INSTRUCTION IONIZING AIR BLOWER PC OPERATION INSTRUCTION Thank you for purchasing this PC Ionizing Air Blower. It is designed to eliminate the static electricity from a charged object. Please read this manual before

More information

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower IONIZING AIR BLOWER MODEL:QUICK442 INSTRUCTIONS Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower The Ionizing AIR BLOWER (OVERHEAD) is a member of the ionizing air blower family. The BLOWER OVERHEAD

More information

Non-toxic Industrial Grade Cleaner, 100% Biodegradable, Environmentally Safe

Non-toxic Industrial Grade Cleaner, 100% Biodegradable, Environmentally Safe n-toxic Industrial Grade Cleaner, 100% Biodegradable, Environmentally Safe Emulsifies Oil, Grease, and Soil for Easy Rinse Away and Leaves NO Residue Safe for ALL Cleanups, Personnel, Marine and Wildlife

More information

Focused Solutions for PARTS WASHING. LOWEST TOTAL COST OF OWNERSHIP Reduced Disposal Fees Reduced Solvent Cost Eliminate monthly rental fees

Focused Solutions for PARTS WASHING. LOWEST TOTAL COST OF OWNERSHIP Reduced Disposal Fees Reduced Solvent Cost Eliminate monthly rental fees Focused Solutions for PARTS WASHING LOWEST TOTAL COST OF OWNERSHIP Reduced Disposal Fees Reduced Solvent Cost Eliminate monthly rental fees Waste Stream Minimization Zep s Exclusive multi-stage filtration

More information

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES.

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES. 3245 Corridor Drive, Eastvale, CA 91752 800.769.2414 951.360.1600 951.360.7500 (Fax) OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) FOR YOUR

More information

PROLAQ. New product for Cleaning solution for water & solvent based paints, varnishes & inks MAKING GREEN WORK.

PROLAQ. New product for Cleaning solution for water & solvent based paints, varnishes & inks MAKING GREEN WORK. New product for 2016 PROLAQ Cleaning solution for water & solvent based paints, varnishes & inks Bio-Circle Surface Technology GmbH Fly - PROLAQ - EN - AL1 2016 /AQS UK Subject to technical modifications.

More information

CASE STUDY #4 - Solvent for Parts Washer. Problem Summary:

CASE STUDY #4 - Solvent for Parts Washer. Problem Summary: 1 CASE STUDY #4 - Solvent for Parts Washer Problem Summary: Clear-Loc Fastener Company uses 16 screw and stamping machines to produce fasteners for the aircraft industry. In between every other machine

More information