Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)
|
|
- Angel Douglas
- 5 years ago
- Views:
Transcription
1 4 Technical Data The following tables and drawings provide an overview of the most important dimensions and properties of Solvis- Max Gas and SolvisMax Gas Pur. 4.1 Volumes and heat loss SX-356 SX-456 SX-656 SX-756 SX-956 Technical Data SX-356 Pur SX-456 Pur SX-656 Pur SX-756 Pur SX-956 Pur Rated volume (l) Actual volume (l) Storage tank distribution Hot water standby volume (l) Economy Standard Comfort Heating buffer volume (l) Solar volume (l) (2) (1) Can be selected at the S1 storage tank top sensor position (2) Results from the difference between the heating buffer volume + hot water volume and the actual volume (3) 60 C in storage tank, 20 C in installation room 82 (1) 195 (1) 357 (1) Heat loss Heat loss (W/K) Heat loss (kwh/24h) (3) Dimensions and performance data SolvisMax Gas and SolvisMax Gas Pur Tank material St 37-2, primed exterior, raw interior Upper bleeder socket ½ female thread Solar inflow (Cu pipe) 10 mm clamp ring screw connection (1¼ male on Pur) Solar return (Cu pipe) 10 mm clamp ring screw connection (1¼ male on Pur) Connection for heating inflow and heating return (corrugated pipe) 1¼ male thread/28 mm Connection for cold water and hot water 28 mm clamp ring bracket Fittings for filling and draining (corrugated pipe) 1¼ male thread/28 mm Gas connection ½ male thread Exhaust connection: Air intake exhaust fittings DN 125/80 Max. tank operating pressure 3 bar Max. temperature in tank 95 C Max. inflow temperature 70 C Minimum circulation water quantity None Max. total volume flow for heating circuits 2,000 l/h Pressure loss on heating water side No measurable pressure loss Hot water heat transfer SolvisMax Gas and SolvisMax Gas Pur Fresh water heat exchanger Plate heat exchanger WWS-24, stainless steel , soldered Permitted operating pressure PWT 16 bar Hot water production circulation pump Type Wilo RS 15/7-1 Max. pressure loss on drinking water side At 1,500 l/h 0.7 bar 20 F 12-M Subject to technical changes 09.08
2 The dimension specifications for the following drawings can be found on the next page. Accessories: 1 Exhaust inspection angle Scope of delivery: 2 Exhaust measuring device approx. ca Solar-Vorlauf for solar flow approx. ca Solar-Rücklauf for solar return Front view Side view T U ~ 555 ~ 715 ~ 860 Top view Tilt height F 12-M Subject to technical changes
3 Insulation SolvisMax Gas SolvisMax Gas Pur View from below R SI SR HI HR BFD Flush, return Flush, inflow HI HR BFD/SR SI Schematic view of the connections Dimensions and weight SX-356 SX-356 Pur SX-456 SX-456 Pur SX-656 SX-656 Pur SX-756 SX-756 Pur SX-956 SX-956 Pur Diameter without insulation d Diameter with insulation D ,020 1,020 Base diameter F Height without insulation h 1,511 1,761 1,833 1,823 2,213 Height with insulation H 1,600 1,850 1,920 1,920 2,290 Depth with insulation and controller T 1,375 1,375 1,485 1,535 1,535 Tilt height without insulation k 1,525 1,770 1,845 1,840 2,235 Height of exhaust supports DN 125/80 (1) A 1,376 1,626 1,626 1,626 1,626 Centre of exhaust supports to back of insulation U 1,063 1,063 1,175 1,175 1,175 Height of condensate connection (2) ,394 Connection dimension with insulation R ,000 1,000 Minimum clearance at front Minimum clearance at sides and to rear Total weight when empty (kg) incl. insulation and protective cover All dimension specifications in mm (1) Floor to upper edge of exhaust support (2) Floor to centre of condensate connection Approx. 204 Approx. 222 Approx. 246 Approx. 252 Approx F 12-M Subject to technical changes 09.08
4 4.3 Combustion data 5-20 kw 7-25 kw 8-30 kw Fuel Natural gas/liquid gas (1) Burner type Blower burner Rated heat output (burner performance) 5-20 kw 7-25 kw 8-30 kw Rated heat output (boiler performance) P n at 80/60 C kw kw kw Rated heat output (boiler performance) P n at 50/30 C kw kw kw Standard efficiency coefficient η N at 75/60 C % % % Standard efficiency coefficient η N at 40/30 C % % % Device category Natural gas and liquid gas connection pressure (1) II2ELL3B/P mbar Exhaust temperature at 75/60 C max. performance 64 C 65 C 67 C Exhaust temperature at 75/60 C, min. performance 61 C 62 C 63 C Exhaust mass flow at 75/60 C max. performance 8.0 g/s 10 g/s 12 g/s Exhaust mass flow at 75/60 C, min. performance 1.8 g/s 2.5 g/s 2.8 g/s Max. supply pressure at boiler end Installation types according to TRGI 100 Pa B 23 / B 33 / C 13x / C 33x / C 43x / C 63x CO 2 content with natural gas at max. performance 9.9 % CO 2 content with liquid gas at max. performance 12.0 % CO standard emission factor (2) 0.9 mg/kwh 1.3 mg/kwh 4.7 mg/kwh NOx standard emission factor (2) 18.7 mg/kwh 29 mg/kwh 45.4 mg/kwh Acoustic emissions from burner at max. performance Acoustic emissions from burner at min. performance Energy efficiency certification (3) < 40 db (A) < 30 db (A) Exhaust support diameter DN 80 (1) The UBS-SX refitting kit is required for operation with liquid gas. (2) The specifications of SolvisMax Gas (5-20 kw) are lower than the limit values of the Hamburg model (issue 7/97). (3) SolvisMax Gas meets the requirements of the EU Efficiency Directive 92/42/EEC. F 12-M Subject to technical changes
5 4.4 Electrical power consumption Technical Data SolvisMax Gas and SolvisMax Gas Pur Slumber mode 5 W Max. power consumption at 5, 7 or 8 kw/20, 25 or 30 kw 19/38 W* Solar pump (speed-dependent) Rated output 60 W (not for Pure) Hot water pump (speed-dependent) Rated output 132 W Circulation pump On site Heating circuit pump On site * Electrical power consumption with blower and without pumps 4.5 Solar installation unit equipment Component SolvisMax Gas Solar circuit pump Vane pump Adjusting valve Adjusting valve DN 15, 1 to 4 l/min Bleeder Manual Manometer 0 to 6 bar Solar safety valve 4 bar, DN 15 Solar circuit pressure switch Switching point at < 0,8 bar Solar heat exchanger Cu pipe bundle heat exchanger integrated in stratified charger Liquid contents 0.5 l 4.6 Safety technology Component Storage tank top (sensor S1) Electronic safety temperature limiter (estb) Rev check for blower Two gas solenoid valves Gas-air compound control Flame monitor Function Monitor function for boiler temperature > 95 C (automatically switches on again when the temperature decreases to < 90 ; factory setting) Limiter function for boiler temperature > 105 C (can only be unlocked manually at the SolvisControl or the automatic firing system, see page 43); function for water shortage and overtemperature Compares target rev to actual rev Shuts off the gas supply gas-air compound control (dual safety) Regulates the gas supply in proportion to the air intake flow; this means that when there is no air flow, no gas can flow into the burner, even if the valves are open Measures the ionisation current = flame detection 4.7 Qualifications Explanation DVGW certificate CE marking Ecolabel DGS/ISES Solar Prize (1998) Excellent technical solar product Öko-Test (Sept. 1998) IEA SHC - Task 26 Solar Combisystems (Dec. 2002) DVGW quality mark Gas (QG-3112AT0007) CE-0085 AS0280 Blue Angel (RAL-UZ 61): Low-emission and energy-efficient gas condensing systems Excellent technical solar product Recommended By far the best European solar heating system 24 F 12-M Subject to technical changes 09.08
6 4.8 Technical data: SolvisControl Mains voltage 230 V~/50-60 Hz Micro-fuse M 6.3 A/230 V~ T 1.0 A/230 V~ Ambient temperature 0-50 C Rated current load A1, A2, A6, A7: each 230 V~/1 A; relay outputs max. each 230 V~/3 A, sum of currents should not exceed 6.3 A Power consumption Approx. 5 W (in slumber mode, without pumps) Timer function without power supply Power reserve for 1-2 days Housing protection class IP 30 Temperature sensor type PTC 2 kohm (except the solar flow and return, outdoor sensor: PT 1000) Temperature display 35 to +250 C Display resolution 0.1 K Measurement accuracy ± 1 K in C range Display 250 Display 35 Message: Delta-T solar Sensor not connected, sensor or cable breakage Sensor short circuit Solar yield is too low (fault in solar circuit) Rev controller A1: Phase angle control or impulse packet A2, A6 and A7: Impulse packet Switch output 230 V~ A1 to A13: 230 V~, A14 floating Analogue output 0-10 V = O1 - O3 Anti-skid control* Heating circuit pumps (user-defined for A1 - A14, factory setting: off) * Anti-skid control: the heating circuit pumps can be individually set on the SolvisControl so that they run on specific days for a certain length of time. Time and duration can be changed. 4.9 Resistance measurement values of the temperature sensors Temperature Resistance [W] Temperature Resistance [W] [ C] PTC (2kW) PT 1000 NTC (10 kw) [ C] PTC (2kW) PT 1000 NTC (10 kw) 0 1,630 1,000 32, ,980 1,309 1, ,772 1,039 19, ,182 1, ,922 1,078 12, ,392 1, ,000 1,097 10, ,607 1, ,080 1,117 8, ,817 1, ,245 1,155 5, ,915 1, ,417 1,194 3, ,008 1, ,597 1,232 2, ,166 1, ,785 1,271 1,751 Unconnected sensors have the resistance values that are shown in the table at different temperatures. These resistance values can be checked with an ohmmeter if a defective sensor is suspected. Sensor types and their application: PT 1000: Solar flow, solar return, outdoor sensor PTC (2 kω): All other sensors NTC (10 kω): Electronic safety temperature limiter (estb) Checking the estb Two NTC 10 kω sensors are integrated into the estb. These use the central conductor (pink) as a common earth line (GND). Each individual sensor is measured between the outer and central conductor. F 12-M Subject to technical changes
Storage tank size Rated volume [l] Actual volume [l]
10 Technical Data Volumes and heat loss Storage tank size 356 456 656 756 956 Rated volume [l] 350 450 650 750 950 Actual volume [l] 365 448 623 695 886 Hot water standby volume [l] Economy Standard Comfort
More informationSimple solutions are usually the best...
Simple solutions are usually the best... The new heating system. SolvisMax. Energy Globe Award 2003: More than 1,000 candidates from 95 countries competed. Solvis took the prize.... 2 We really just wanted
More informationWOLF GAS CONDENSING BOILERS COMFORTLINE
WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build
More information24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.
24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers
More informationStokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing
Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020
More informationThe competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28
The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More informationECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT
ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com
More informationCalder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model
Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder
More information24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus
24-28 kw Conventional Combi Gas Boiler Lawa / LawaPlus Conventional Combi Gas Boilers Warmhaus wall-hung gas combi boilers Lawa and LawaPlus, with the advantage of its width as 288mm, are easily fit to
More informationLogamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.
Technical Guide Issue 2011/06 Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein. Sie finden die Bilder auf der Referenzseite 14: Buderus Product groups. Anordnung im Rahmen: - Tops
More informationInstallation Plan. Professional Dishwasher PG Mat. no.: en - US
Installation Plan Professional Dishwasher PG 8056 Mat. no.: 10 251 400 en - US Installation instruction Observe installation instructions when installing machine. This dishwasher is suitable for residential
More information24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.
combi boilers panel radiators 24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus www.warmhaus.com 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-33/40 kw Warmhaus
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More information24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus
24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-32/40 kw Warmhaus wall-hung gas combi boilers Priwa and PriwaPlus,
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS 12-Month Maintenance Procedures These instructions apply to the following BMK boiler models (Standard & Dual Fuel): Benchmark 1.5LN Benchmark 2.0LN Benchmark 3.0LN Benchmark 750
More informationSuperior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw
Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationHeat. Life. Future SolvisMax The All Rounder
Heat. Life. Future SolvisMax The All Rounder 7 Series SolvisMax Product Presentation SolvisMax 7 Contents: SolvisMax 7 The All Rounder Front and Side Casing Parts, Pipe Lead Through Openings Flange and
More informationInstallation Plan. Professional Dishwasher PG Mat. no.: en - US
Installation Plan Professional Dishwasher PG 8061 Mat. no.: 09 838 370 en - US Installation instruction Observe installation instructions when installing machine. This dishwasher is only suitable for commercial
More informationTechnical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW
Technical documentation ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW ComfortLine gas condensing boilers Benefits of the WOLF gas condensing boilers up to 24 kw CGB-2(K) / CGW-2 / CGS-2
More informationInstallation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ
Installation plan: PG 8581 PG 8583 Mat. no. 10 390 400 Version 02 GB, IE, AU, NZ Technical data sheet Washer-disinfector PG 8581-8583 Legend: Circled, bold-type abbreviations: Connection required Abbreviations
More informationAppendix 8: Generic System #15: Two Stratifiers in a Space Heating Storage Tank with an External Load-Side Heat Exchanger for DHW
Report on Solar Combisystems Modelled in Task 26 Appendix 8: Generic System #15: Two Stratifiers in a Space Heating Storage Tank with an External Load-Side Heat Exchanger for DHW A Report of IEA SHC -
More informationCalder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model
Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency
More informationWALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C
ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS 24-Month Maintenance Kit P/N 58025-06 For BMK2.0LN Boilers Description of Document: This TID provides the procedures to perform recommended 24-Month maintenance on the following
More informationCAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL
BRILEY CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER 60 140 kw 0604.2 Beeston Briley cast-iron premix gas-fired boiler 60-140kW Contents 1 Boiler specifications Page 3 2 Appliance general dimensions
More informationCOMPACT FLAME CONTROLLER CFC 100
COMPACT FLAME CONTROLLER CFC 100 TECHNICAL DESCRIPTION EDITION: TB CFC100 EN REV. 1 2012-03-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationWHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS
WHU WATER HEATING UNITS GENERAL MANUAL MODEL KEY WHU Water Heating Unit Maximum heating power, kw Max. water inflow pressure, bar Voltage options GENERAL INFORMATION WHU water heater, producing hot water
More informationHIGH OUTPUT. Skin design RANGE
Light drop design HIGH OUTPUT Skin design RANGE Trim design 1 Product Introduction Product Presence Worlwide 2 Product Presentation Bosch Model Commercial Name: GWHC 27 3 Product Presentation Product Design
More informationWOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE
WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE CGB-2(K) / CGW-2 / CGS-2L / CGS-2R / CSZ-2 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial
More informationSPECIFICATIONS - NIKE
Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks
More informationMaximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:
Maximiser SE USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE: 705.276A-3233 11-2000 INTRODUCTION It is essential that the instructions in this booklet are strictly followed, for safe and economic
More informationVIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.
VIESMANN VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW Datasheet Part no. and prices on request VITOMAX 200-LW Type M64A
More informationINSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20
INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8
More informationWOLF VENTILATION SYSTEM PRICE LIST
VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation
More informationInfrared Diesel Heater
Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the
More informationCOMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)
COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the
More informationVIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l
Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these
More informationTechnical data LA 60TU
Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)
Dual sensor flame scanner (rev B) Application: - Wall fired and corner fired boilers - Gas, oil and coal multi-fuel burners Combined PbS IR sensor and high sensitivity UV tube Continuous self-checking
More informationTechnical data LA 28TBS
Technical data LA 28TBS Device information LA 28TBS Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationVIESMANN. Installation instructions VITOMAX 200-HW. for contractors
Installation instructions for contractors VIESMANN Vitomax 200-HW Type M238 Oil/gas fired high pressure hot water boiler Combustion output 4.0 to 18.2 MW VITOMAX 200-HW 6/2007 Dispose after installation.
More informationSelf-learning Room Temperature Controller
2 226 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch and possibility of remote control RAV12 Mains powered room temperature controller featuring straightforward operation.
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationSelf-learning Room Temperature Controller
2 224 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch RAV11 Mains-independent room temperature controller featuring straightforward operation. Self-learning two-position
More informationLOW NOx MODULATING GAS BURNERS
RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw
More informationSelf-learning Room Temperature Controller
2 257 Self-learning Room emperature Controller 5 operating modes and menu selection via roller selector REV16 Mains-independent room temperature controller Straightforward, self-explanatory menu selection
More informationSelf-learning Room Temperature Controller
Self-learning Room emperature Controller with two 24-hour operating modes Mains-independent room temperature controller featuring straightforward operation and an easy-to-read display. Self-learning two-position
More informationECONOFLAME R6000 GAS FIRED CONDENSING BOILERS (KM628 CONTROLLER)
ECONOFLAME R6000 GAS FIRED CONDENSING BOILERS (KM628 CONTROLLER) INSTALLATION, OPERATION & MAINTENANCE DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 8783 3050
More informationServicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use
GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents
More informationInstallation manual Operating instructions
WIKORA GmbH Friedrichstr. 9 89568 Hermaringen Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Operating instructions DHW storage tank UNO/DUO/H/WPSOL Installation
More informationServicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use
GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents
More informationMetropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h
Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure
More informationQuinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission
The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT
More informationTechnical data LA 60TUR+
Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors
More informationAir curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain
Air curtains 114 MRX condensing gas air curtain 118 MRA-H gas air curtain 121 MRA-A ventilation only air curtain 122 SW / SE hot water / electrical air curtain 124 SWR / SER built-in hot water / electrical
More informationProduct Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S
D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust
More informationSelf-learning Room Temperature Controller
2 252 Self-learning Room emperature Controller with one weekly operating mode including individual 24-hour modes and three 24-hour modes, cooling function REV22 Use Mains-independent room temperature controller
More informationAGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING
MADE IN ITALY residential condensing D.H.W. up to 10 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 100% CONDENSING AGUAdens TM wall-mounted water heaters (16-22 -37 litres) AGUAdensTM INSTANTANEOUS
More informationPRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW
We develop for your future! PRODUCT INFORMATION Hygienic stratification storage tank Universal heat center for legionella safe preparation of DHW Technical description Solarbayer GmbH (18.12) Solarbayer
More informationPZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL
BIOTECH THE FUTURE OF HEATING PZ 35 RL Heating with renewable energies is the future and you will not only contribute to the environment, you also will reduce massively your annual energy cost. The Biotech
More informationREMKO Comfort-WP The versatile heat pump
REMKO Comfort-WP The versatile heat pump Issue 2012 Independent from oil and gas Cosy heat in the winter A pleasant climate in the summer CMF Series 1-2014 Quality with systems REMKO THE CUSTOMER-ORIENTED
More informationHigh temperature hydrobox for VRV
High temperature hydrobox for VRV For efficient hot water production and space heating Air to water connection to VRV for applications such as bathrooms, sinks, underfloor heating, radiators and air handling
More informationin/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)
CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used
More informationHoval TopGas (12, 16, 22)
Hoval TopGas (2, 6, 22) Wall gas condensing boiler with or without calorifier TopVal Description Hoval TopGas Boiler Wall mounted gas condensing boiler Heat-exchanger out of corrosion resistance aluminium
More informationFEATURES AND BENEFITS. Up to 109.8% part load efficiency
IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS Benchmark 3.0LN 24-Month Maintenance Kit# 58015-04 This kit applies to units with an Ignitor and a separate gas injector. For units with an Ignitor-Injector (P/N 58023), see Kit
More informationIndex. Introduction. Pg 2. Powersaver - Single Element. Pg 3-5. Powersaver - Dual Element. Pg 6-11
family Index Introduction Powersaver - Single Element Powersaver - Dual Element Pg 2 Pg 3-5 Pg 6-11 The Powersaver range provides the time control facility needed to help households lower their electric
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationVD 53 - Vacuum drying oven for non-flammable solvents
Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat
More informationInstallation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr
Installation Plan Laboratory Glassware Washer PG 8583 CD M. Nr. 10 341 990 en US Installation Instructions Please read and observe the instructions in the operating instruction manual and the service documents
More informationIMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS
THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.
More informationStainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW
Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents
More informationREMKO HYBRID HEAT PUMPS
REMKO HYBRID HEAT PUMPS Switch over to more efficiency even in old buildings HBW series 1-2014 Quality with systems THE HYBRID TECHNOLOGY Two technologies combined into one innovation "Hybrid comes from
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS 24-Month Maintenance Kit P/N 58025-04 For BMK3.0LN Boilers Description of Document: This TID provides the procedures to perform recommended 24-Month maintenance on the following
More information30 SD & 45 SD CONDENSING BOILERS
ETHOS 30 SD & 45 SD CONDENSING BOILERS Installation and Operating Manual Issue 01/07 Combustion fan CONTENTS 1 SAFETY GUIDELINES...1 1.1 Conditions...1 1.2 General guidelines...1 2 TECHNICAL DATA...2 2.1
More informationABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)
Flame scanner for gas and oil burners (Rev. B) Application: - Wall fired boilers - Gas and oil burners High sensitive UV tube Continuous self-checking Rugged detector head for harsh environments: - Protection
More informationENERGY TOP. Condensing boiler solutions
ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for
More informationTechnical data LA 9S-TU
Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationSIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A
cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors
More informationVIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A
Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions
More informationCOMPACT FLAME CONTROLLER CFC 1000
COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationRIELLO 40 GS/M SERIES
The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.
More informationHot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological
Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution
More informationInstallation plan: PG Mat. no Version 00 US
Installation plan: PG 8504 Mat. no. 10 344 110 Version 00 US Technical data sheet PG 8504 Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection
More informationDual Top RHA-100 Dual Top RHA-101/102
Visit for more technical information and downloads. Air heaters 03/2003 Integrated heater Workshop Manual RHA-100 RHA-101/102 10/2009 9019782B Visit for more technical information and downloads. Improper
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to
More informationBG2000S PRE-MIX GAS BURNER
BG000S PRE-MIX GAS BURNER INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 77 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationLFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02
7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil
More informationREA22 Room Temperature Controller
REA22 Room Temperature Controller Basic Documentation Issue: 2.0 Controller series: A CE1P2276E 31.03.1999 Siemens Building Technologies Landis & Staefa Division Siemens Building Technologies Ltd. Landis
More informationHOT WATER SYSTEMS.
HOT WATER SYSTEMS www.thermann.com.au GAS STORAGE HOT WATER SYSTEM The Thermann 4* Gas hot water heater can suit any family type. With an adjustable thermostat for safety and efficiency it allows you to
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationINSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO
INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply
More informationThe Meibes concept for the specialist: Easier. Quicker. More successful.
P R I C E L I S T 3 5 V A L I D F R O M 0 1. 0 1. 2 0 1 0...for the professional installer The Meibes concept for the specialist: Easier. Quicker. More successful. Easier Complete pre-assembled modules
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationAluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support
Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of
More informationGas cooler series TC-Standard+
Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control
More information