Document code: 1 (10) Issuing date: Status:

Size: px
Start display at page:

Download "Document code: 1 (10) Issuing date: Status:"

Transcription

1 Document code: 1 (10) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION DUCT BURNERS Submitted for: Customer reference: Other information:

2 Document Code: 2 (10) TABLE OF CONTENTS 1 GENERAL DESIGN DATA Duct burner Fuels Atomizing medium Combustion air Igniter Fuel Air Supply voltage EQUIPMENT DATA Duct burners Type of nozzle Valve set for burners Oil Purging air Atomizing air Ignition gas Instrument air Flame monitors Ignition burner AUTOMATION AND INSTRUMATION General System control Starting the PURGE Duct burners basic logic Fuel oil flow control Fuel oil pressure control Minimum oil flow Measurements Interlocking CONNECTED SYSTEMS APPENDICES... 10

3 Document Code: 3 (10) 1 GENERAL The function of the duct burner is raise the temperature of the primary air and in that way support start-up burners bring the bed temperature up with to the permissible peat ignition temperature. Equipments which are included in the system are introduced in P&I -diagrams S1 HHA -MFB0001 Duct burners are located in the primary air duct. Burners are normal air atomizing (plant air) oil burners completed with a burner management control and safety system. Propane / butane gas is used as ignition gas. Pressurized air is used as atomizing medium, the pneumatic valves and cylinders are controlled by means of instrument air. Main combustion air for the burners is hot primary air. Intrex air supply is for cooling air of flame scanners and combustion air for the igniters. During startup, the boiler must be uniformly heated so that the parts are not damaged by thermal stress. The burners must be started and the primary air duct slowly brought up to a temperature that will allow safe level (below 400 C). Maximum load of the one duct burner is approx. 4 MW with control ratio 1:4. This provides about 8 MW duct burners heat input to the boiler. There are two duct burners on primary air duct. The initial setpoint for feeding of solid fuel will be greater than 500 C and one start-up burner must be in use. Once peat is ignited and the bed temperature is greater than 600 C, the burners can be taken out of service. All duct burner valve racks are identical. The main components of the valve rack are two main fuel oil safety shut-off valves, two ignition gas shut-off valves, one ignition gas ventilation valve, clean purging valve, safety shut-off valves and one atomizing purge valve, four manual isolation valves for the instrument air, fuel oil, ignition gas and atomizing pressure air and two non-return valves for atomizing and clean purging. Ignition gas and instrument air lines are equipped with strainers. Connection between the valve racks and burners is carry out by the flexible metal hoses, which allow the thermal movement of the burner without putting stress to the piping of the valve racks. Each duct burner valve rack has a local control panel with a flame detector signal amplifier and flame intensity meter. From the local operating panel it is possible to start and stop the burner sequence program through commands from the Distributed Control System. The local panel functions as termination panel for a burner and valve train electrical devices and instruments. The burner assembly consists of a burner register and windbox, front plate with inspection sight glass, retractable lance with extended and retracted limit switches, impeller, main fuel lance coupled switch, two flame detectors, gas igniter and igniter high voltage transformer package for spark initiation. A small quantity of intrex air are used to provide purging, sealing and cooling for the burner assembly. Each duct burner has a refractory hood which protects the immediate primary air ducts from excessive heat and gives shape and a direction to the ignition flame.

4 Document Code: 4 (10) 2 DESIGN DATA As a design basis for the duct burner system are the following data. 2.1 Duct burner Fuels Quality: Light fuel oil Capacity: max. 300 kg/h oil Temperature: 30 C Oil supply pressure: 16 bar Atomizing medium Quality: Consumption: Pressure: plant air 30 kg/h 6 bar Combustion air Quantity: 3450 Nm 3 /h Continuous flow: 3450 Nm 3 /h Pressure: 0,2 bar Temperature: C 2.2 Igniter Length L= Fuel Quality: LPG Consumption: 13,5 Nm 3 /h Supply pressure: 0,5..1,5 bar

5 Document Code: 5 (10) Air Quality: HP air Consumption: 270 Nm 3 /h Supply pressure: 0,4 bar Supply voltage Voltage: 8,5 kv 3 EQUIPMENT DATA 3.1 Duct burners Manufacturer Foster Wheeler Energia Oy KKS numbers S1 HHA10/20 AV101 Capacity: max. 300 kg/h oil each Oil supply pressure: 16 bar Control ratio: 1:4 3.2 Type of nozzle WD 6 22, 80, WD 5 13, 80 6 = number of holes 22 = hole diameter (2.2 mm) 80 = angle of holes (WD = type) See also manufacturer's instructions. 3.3 Valve set for burners Each start-up burner has its own valve set consisting of the following items. 3.4 Oil Manual shut-off valve with limit switch for oil Oil quick shut-off valves (2 pieces) Pressure gauge for oil

6 Document Code: 6 (10) 3.5 Purging air Manual shut-off valve for purging air Purging air quick shut-off valve Pressure switch for purging air Back pressure valve for purging air 3.6 Atomizing air Manual shut-off valve for atomizing air Atomizing air quick shut-off valve Pressure gauge for atomizing air Pressure switch for atomizing air Back pressure valve for atomizing air 3.7 Ignition gas Manual shut-off valve for ignition gas Electric quick shut off valves (3 pieces) Filter for ignition gas 3.8 Instrument air Manual shut-off valve Filter for instrument air Solenoid valve group: For quick shut-off valve of atomizing air For first shut-off valve of purging air For second quick shut-off valve of purging air For first quick shut-off valve of oil For second quick shut-off valve of oil Throttle valve for first quick shut-off valve of oil 3.9 Flame monitors Manufacturer Durag Type Flame sensor D LE603 Type Flame monitor control unit D-UG 660

7 Document Code: 7 (10) 3.10 Ignition burner Manufacturer Foster Wheeler 4 AUTOMATION AND INSTRUMATION 4.1 General Bed will be heated by duct and start-up burners during start-up and firing of a low-grade solid fuel, which is not capable to keep bed temperatures high enough. The effect of the duct burners will be controlled by altering the oil flow rate. There are two different ways to control start-up burners: oil pressure control oil flow control. Pressure control must be used when starting the first burner. The other burner can be started by using flow control. Control mode will be chosen by setting the desired controller in automatic mode. Now the controller that has been earlier on automatic mode falls off from controlling. For more details of control and function you find from function description of duct burners. 4.2 System control Before starting the first burner, furnace has to be purged if the bed temperature is under 600 C Starting the PURGE PURGE can be started on the screen from switch "PURGE", then control loops of secondary air for lower and upper level switches to manual control mode and PURGE logic starts to open the control dampers. When total air flow to the boiler is > 50 % the dampers are locked in their position and PURGE time begins. When furnace has been purged and boiler interlocking is in order, boiler is ready for ignition. Now secondary air controls switch to cascade modes. Boiler is ready for ignition if less than 30 minutes has passed after stopping the PURGE.

8 Document Code: 8 (10) Duct burners basic logic Duct burner starts according to the following sequence: 1. Booster fan starts and air damper to the ignition position * Pressure difference enough for ignition 2. Atomizing air valve opens * atomizing air pressure > min 3. Ignition transformer on, ignition gas valves open 4. Flame observed 5. Oil shut-off valve of oil opens. * quick-close valves on open limit and flame observed 6. Ignition transformer off, ignition gas valves close * flame observed 7. Air damper to the cascade mode A duct burner stops according to the following sequence 1. Air damper to the ignition position * Pressure difference enough for ignition 2. Ignition transformer on, ignition gas valves open * flame observed 3. Oil Shut-off valve closes, purging air valve open * quick-close valves close and purging air valve open, flame observed 4. Purging air valve closes (30 s purging) * flame observed 5. Ignition transformer off, ignition gas valves close 6. Air damper to the cascade mode * Burner out 7. Atomizing air valve closes. If the duct burner stops because of interlocking without purging, stop sequence must be started manually again after the interlocking has been released. 4.3 Fuel oil flow control When oil control is in pressure control mode, output of this flow control follows output of pressure controller. In that way pressure impulses can be avoided when changing the control mode. Controller has control modes as follows: Manual mode Position of control valve will be controlled manually 0-100% Automatic mode The controller controls constant flow set point.

9 Document Code: 9 (10) 4.4 Fuel oil pressure control First burner is started by using pressure control mode. The controller ensures that oil pressure will not fall below the minimum level when burners are in use. Controller has control modes as follows: Manual mode Position of control valve will be controlled manually 0-100%. Automatic mode The controller controls constant pressure set point. 4.5 Minimum oil flow Close valve in duct burners oil return line, which closes automatically when oil valves in some duct burner open. Valve opens when oil valves in both burners are closed (hand valve or both quick closing valves). 4.6 Measurements See the automation descriptions. 4.7 Interlocking See the automation descriptions. Burners are ready for use when boiler interlocking are in order and burner is ready for operation (no alarms on).

10 Document Code: 10 (10) 5 CONNECTED SYSTEMS Flue gas system Primary air system Instrument air distribution in boiler house Pressurized air distribution in boiler house Fuel oil Ignition gas Intrex air S1 HN -MFB0001 S1 HL -MFB0001 S1 QFH -MFB0001 S1 QEH -MFB0001 S1 HJ -MFB0001 S1 HJ -MFB0001 S1 QDA -MFB APPENDICES Control- and logic diagrams Duct burner system S1 HHA -MFB0001

Document Code: 1 (13) Issuing date: Status:

Document Code: 1 (13) Issuing date: Status: Document Code: 1 (13) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION REHEAT STEAM SYSTEM Submitted for: Customer reference: Other information:

More information

Document Code: 1 (15) Issuing date: Status:

Document Code: 1 (15) Issuing date: Status: Document Code: 1 (15) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: HSK Document title: SYSTEM DESCRIPTION BOILER WATER SYSTEM Submitted for: Customer reference: Other information:

More information

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support Main Burner Main Reaction Furnace Design Weather shield View ports Weather shield LMV Burner Burner / Furnace connection Residence

More information

Document Code: 1 (5) Issuing date: Status:

Document Code: 1 (5) Issuing date: Status: Document Code: 1 (5) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION MAIN CONDENSATE PUMPING Submitted for: Customer reference: Other information:

More information

Steam Fundamentals. (in heating & processing applications)

Steam Fundamentals. (in heating & processing applications) Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals

More information

STEAMPAK Series BurnerPAK BMS Burner Management Systems

STEAMPAK Series BurnerPAK BMS Burner Management Systems BurnerPAK BMS Burner Management Systems Sequence of operation, ignition and control of burners Meets NFPA 85 safety standard MFT alarming with manual reset, first-out indication Optional enhanced alarming

More information

Chemical Processes in the Combustion

Chemical Processes in the Combustion FLAMES Chemical Processes in the Combustion C + O 2 CO 2 + 94,1 kcal C x H y + [2x+ y / 4 ] O 2 x CO 2 + y / 2 H 2 O + z kcal Burner Flame Air Fuel Air Flame Ignition Ignition of Flames: Ignition Energy

More information

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

Specifications of V-Line burners

Specifications of V-Line burners Duct Burners - V-Line 4-22.5-7 Specifications of V-Line burners V-Line burner firing on natural gas - constant combustion air 60 F - 21% O 2 combustion air - 50% rel. humidity - natural gas with 1000 Btu/ft³

More information

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660 Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL OPERATING AND MAINTENANCE MANUAL NVPOM-0104 TABLE OF CONTENTS Section Page 1 SPECIFICATIONS...1 1.1 Nova Plus Specifications...1-1 1.2 Warranty...1-2 2 GENERAL BURNER DESCRIPTION...2 2.1 Burner...2-1 2.2

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT TITLE START UP BURNER ASSEMBLY Phone: +91 431 2574087/2574157

More information

Document Code: 1 (6) Issuing date: Status:

Document Code: 1 (6) Issuing date: Status: Document Code: 1 (6) Issuing date: Status: Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Employer: JJA Document title: SYSTEM DESCRIPTION BOTTOM ASH SYSTEM Submitted for: Employer reference:

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

INDITHERM. Low temperature gas burners

INDITHERM. Low temperature gas burners INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout

More information

SULPHUR RECOVERY UNIT

SULPHUR RECOVERY UNIT 19 October 2015 SULPHUR RECOVERY UNIT START-UP CONSIDERATIONS SHRIKANT KOLI BLACK & VEATCH, MUMBAI Agenda - Burner Management System - Control Loops - Refractory Dry-Out - Start-up Experiences 2 Burner

More information

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC2 THRU NVC6 ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx WITH CONTROLINKS CONTROLS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas

More information

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures. Issued 2005/06/01 Section 15510 Packaged Boilers Page 1 of 13 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout

More information

NMC Nozzle Mix Gas/Oil Combination Burners

NMC Nozzle Mix Gas/Oil Combination Burners NMC Nozzle Mix Gas/Oil Combination Burners NMC-1 Edition 10-08 Burns most gaseous fuels and No. 2 oil Sealed-in capability Stable flame over entire operating range Preheated air to 800ºF (425ºC) Gas pilot

More information

Eclipse 90 UV Scanner Model A Version 1

Eclipse 90 UV Scanner Model A Version 1 85 Instruction Manual 10/14/010 Eclipse 90 UV Model 5600-90A Version 1 C US Introduction This sensor features a high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames that cycle on and

More information

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

UV Scanner. Model Specification. Introduction. 854 Instruction Manual 854 Instruction Manual 10/11/010 UV Model 5600-91 C US Introduction This sensor features a high temperature and high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames in applications that

More information

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev. Flame scanner for fuel oil and coal flame (rev. A) Application: - Wall fired, corner fired and down-shot boilers - Oil, Orimulsion and pulverized coal burners PbS sensor to detect flame by infrared (IR)

More information

HAUCK STARJET BURNER SJ075 SJ980

HAUCK STARJET BURNER SJ075 SJ980 INSTRUCTIONS HAUCK STARJET BURNER SJ075 SJ980 WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment by unqualified personnel

More information

"HC" AIRFLO. In-duct firing line burner

HC AIRFLO. In-duct firing line burner "HC" AIRFLO In-duct firing line burner -.- High heat release up to.5 MW per unit of burner length (05 mm) Clean combustion with low CO and NO x emission levels Minimal process air pressure drops locally

More information

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10 Model C Forced Draft Burners Natural Gas or Propane MODEL C10 MODEL C4 GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7 Telephone: (519) 620-0230 Telefax: (519) 620-0232

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103 pending pending Controlling and Monitoring of Gas, Oil and Combined Burners of any Capacity Integrated Gas Valve Proving System Separated Outputs for Gas- and Oil Fuel Valves Quick Fuel Change on the fly

More information

SECTION GAS-FIRED RADIANT HEATERS

SECTION GAS-FIRED RADIANT HEATERS SECTION 23 55 23 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

PELLET BURNER PV 350

PELLET BURNER PV 350 PELLET BURNER PV 350 INSTRUCTION MANUAL v1.1 1 PRODUCT DESCRIPTION...3 2 SAFETY RULES...3 3 WARNINGS...4 4 INSTALLATION INSTRUCTIONS...5 4.1 BOILER REQUIREMENTS...5 4.2 PELLET CONTAINER...6 4.3 INSTALLATION

More information

Eclipse Self-Check UV Scanner

Eclipse Self-Check UV Scanner 856 Instruction Manual 10/18/2010 Eclipse Self-Check UV Model 5602-91 Version 1 Introduction The self-check UV is used for continuous gas or oil flames. A mechanical shutter in the scanner closes briefly

More information

FIREYE FLAME SCANNERS

FIREYE FLAME SCANNERS UV90 SC-102 MAY 2002 FIREYE SCANNERS UV1A UV8A UV non self-checking Scanner Models: UV1A3, UV1A6, UV8A, UV2, UV2A6, UV2C,45UV2, 45UV3, UV90-3. UV90-6, UV90-9 For UV self-check Scanners refer to SC-101

More information

COMPACT FLAME CONTROLLER CFC 100

COMPACT FLAME CONTROLLER CFC 100 COMPACT FLAME CONTROLLER CFC 100 TECHNICAL DESCRIPTION EDITION: TB CFC100 EN REV. 1 2012-03-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas Journal of Contemporary Issues in Business Research ISSN 2305-8277 (Online), 2013, Vol. 2, No. 4, 109-123. Copyright of the Academic Journals JCIBR All rights reserved. NFPA 85 COMPLIANCES OF BMS: A CASE

More information

IE059: Boiler Control and Instrumentation for Engineers & Technicians

IE059: Boiler Control and Instrumentation for Engineers & Technicians IE059: Boiler Control and Instrumentation for Engineers & Technicians IE059 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: This five-day intensive course introduces the practices of controls

More information

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02 7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil

More information

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable

More information

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications 2.1 GENERAL A. Reference is made to the clause entitled Buy American Act Balance of Payments Program Construction Materials FAR 52.225-9. Notwithstanding a bidder s right to offer identifiable foreign

More information

Kolmetz Handbook Of Process Equipment Design BURNER MANAGEMENT SYSTEMS (ENGINEERING DESIGN GUIDELINE)

Kolmetz Handbook Of Process Equipment Design BURNER MANAGEMENT SYSTEMS (ENGINEERING DESIGN GUIDELINE) Practical Engineering Guidelines for Processing Plant Solutions SOLUTIONS, STANDARDS AND SOFTWARE www.klmtechgroup.com Page : 1 of 78 Rev 1 KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman

More information

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00 EXCESS AIR BURNERS XNM SERIES FEATURES Mixer: cast iron G25 Plate: cast iron G25 Air tube: AISI304 Preheated air: up to 450 Suitable for different types of gas: CH 4 /L.P./propane/etc Standard refractory

More information

RL 28/2-38/2-50/2 Low - High Operation

RL 28/2-38/2-50/2 Low - High Operation Installation, use and maintenance instructions Light Oil Burners RL 28/2-38/2-50/2 Low - High Operation C6505050 CONTENTS WARNING TECHNICAL DATA..............................page 3 Burner models.....................................

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

RL 70/2-100/2-130/2 Low - High Operation

RL 70/2-100/2-130/2 Low - High Operation Installation, use and maintenance instructions Light Oil Burners RL 70/2-100/2-130/2 Low - High Operation C6505052 CONTENTS WARNING TECHNICAL DATA............................. page 3 Burner models.....................................

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

FIREYE FLAME SCANNERS

FIREYE FLAME SCANNERS UV1A UV8A UV5 UV90L SC-108 June 14, 2017 FIREYE FLAME SCANNERS UV non self-checking Scanner Models: UV1AL-3, UV1AL-6, UV90L-1, UV90L-2, UV5-1. UV1AL 45UV3 DESCRIPTION The UV1AL, UV90L, and UV5 scanners

More information

DELTA-TE III. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner 4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process

More information

Fireye FLAME SCANNERS

Fireye FLAME SCANNERS UV7A4 SC-107 APRIL 3, 2013 Fireye SCANNERS UV7SC UV7R4 UV Non Self-Checking Scanner Models: UV7A4, UV7R4 UV Self-Check Scanner Model: UV7SC DESCRIPTION The non self-check UV7A4, UV7R4 and self-check UV7SC

More information

150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer

150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer March 1, 2017 150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer Customer Carey Boiler Works March 1, 2017 Page 2 of 5 Section 10 Boiler... 2 10.1... 2 10.2 Design... 2 10.3 Technical

More information

Indirect gas-fired air heater

Indirect gas-fired air heater Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury

More information

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004 Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

ClearFire - Hydronic Startup Report

ClearFire - Hydronic Startup Report ClearFire - Hydronic Startup Report Date Serial No. THIS FORM IS FOR MODEL CFC / CFW CLEARFIRE BOILERS Customer s Name Location Model Design Pressure Working Pressure Rated Input (nameplate rating) BTU/hr

More information

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

FIREYE FLAME SCANNERS

FIREYE FLAME SCANNERS UV1A UV8A UV90 UV1A UV8A SC-102 MARCH 28, 2013 FIREYE FLAME SCANNERS UV non self-checking Scanner Models: UV1A3, UV1A6, UV8A, UV2, UV2A6, 45UV3, UV90-3. UV90-6, UV90-9 For UV self-check Scanners refer

More information

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System. Product Guide Specification Nexus Integrated Burner Control System 1. General 1.1 Overview Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP Model CB-LE Packaged Boiler 125-200 HP and Model CB Ohio Special 125-225 HP Operation, Service, and Parts Manual 750-184 04/09 ii CLEAVER-BROOKS Model CB-LE Packaged Boiler 125-200 HP Light Oil, Heavy

More information

REGISTER BURNERS URB SERIES URB-SH SERIES

REGISTER BURNERS URB SERIES URB-SH SERIES REGISTER BURNERS URB SERIES URB-SH SERIES 2 1 INTRODUCTION The forced draft burner combines the advantages of the proven register, windbox and fan to supply 100% of air in one complete package. This series

More information

EZ-FLAME Detector USER MANUAL

EZ-FLAME Detector USER MANUAL EZ-FLAME Detector USER MANUAL TABLE OF CONTENTS 1 Introduction... 1 1.1 Unpacking and Inspection... 1 1.2 About this Manual... 1 2 Description... 2 3 System Configuration... 3 3.1 Flexible Fiber Optic

More information

Product Overview Combustion Technology

Product Overview Combustion Technology Product Overview Combustion Technology 2014 DURAG combustion technology Large-scale power plant The DURAG GROUP s products support all types of industrial combustion processes throughout the world. These

More information

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B) Dual sensor flame scanner (rev B) Application: - Wall fired and corner fired boilers - Gas, oil and coal multi-fuel burners Combined PbS IR sensor and high sensitivity UV tube Continuous self-checking

More information

LAE10 LFE10. Use. Series 02

LAE10 LFE10. Use. Series 02 ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,

More information

Solutions to Pollution

Solutions to Pollution Evaporator Information Solutions to Pollution Eliminate waste oils Eliminate or reduce energy costs Eliminate or reduce disposal costs Excellence in Technology, Quality & Service 1 1.0 INOV8 Evaporators

More information

DIRECTIVE NO: D-B

DIRECTIVE NO: D-B DIRECTIVE NO: D-B6 100604 1 LOW PRESSURE THERMAL FLUID PLANT AUTOMATED CONTROL SYSTEMS Date of Issue: June 4, 2010 General Details This directive is being issued to owners, licensed contractors, consulting

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded

More information

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler ClearFire Model CFH Horizontal Steam Boiler Startup Guide 750-293 www.cleaverbrooks.com Improper installation, adjustment, service, or maintenance can cause equipment damage, personal injury, or death.

More information

MEGASTAR TM BURNER MS-25 MS-150

MEGASTAR TM BURNER MS-25 MS-150 INSTRUCTIONS MEGASTAR TM BURNER MS-25 MS-150 WARNING These instructions are intended for use only by experienced, qualified combustion startup personnel. Adjustment of this equipment by unqualified personnel

More information

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m. heater product range commercial 11 HYDRONIC EBERSPÄCHER WATER HEATERS THE RIGHT HEAT WHERE YOU WANT IT The advantage of Eberspächer water heaters is that they pre-heat both the vehicle interior and the

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

PBG PACKAGED GAS BURNER

PBG PACKAGED GAS BURNER INSTRUCTIONS PBG PACKAGED GAS BURNER WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components by unqualified

More information

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B) Flame scanner for gas and oil burners (Rev. B) Application: - Wall fired boilers - Gas and oil burners High sensitive UV tube Continuous self-checking Rugged detector head for harsh environments: - Protection

More information

Rental Boiler Specifications (Nebraska Boiler)

Rental Boiler Specifications (Nebraska Boiler) Rental Boiler Specifications (Nebraska Boiler) ESI's 72,000 pph trailer-mounted watertube steam boilers are designed and built in accordance with ASME Code. Each boiler is arranged for natural gas or #2

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

Single stage operation oil burner

Single stage operation oil burner Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow

More information

Product Overview Combustion Technology

Product Overview Combustion Technology Product Overview Combustion Technology smart solutions for combustion and environment DURAG combustion technology (1) Large-scale power plant The DURAG GROUP s products support all types of industrial

More information

Distributed By: M&M Control Service, INC

Distributed By: M&M Control Service, INC APPROVED The UV1A3/6, UV2/UV2A6/UV2C, 45UV2, 45UV3, UV90-3/6/9 Scanners are used with the M-Series, M-Series II, MicroM, FlameWorx, MB-2 and D-Series controls as well as the Fireye FLAME-MONITOR TM, BurnerLogix

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19 OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers

More information

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued For CERTIFICATE of COMPETENCY EXAMINATION AB-239 Edition 3, Revision 1, Issued 2018-07-13 Visit our Website at www.absa.ca GENERAL INMATION Introduction: As provided for under the Power Engineers Regulation,

More information

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. Burner Management and Combustion Control Rev 5058-CO900E Industrial Combustion Team Overview Background and Industry Experience RA s IC&PG Team Expertise 3 Extensive experience working with Factory Mutual

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS. BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS. Value & Premier Oil Heating System Service Plans Choose the plan that s best for you and your home. WE PROMISE SERVICE PLANS THAT

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS MODEL ADF/ADFH 300 and 500 FOR INDUSTRIAL & COMMERCIAL APPLICATIONS Model ADF CSA 3.7 ANSI Z83.4 Non-Recirculating Industrial Air Heaters WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR USE IN HAZARDOUS

More information

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project

More information

TAPPI PEERS Working Towards a Safer

TAPPI PEERS Working Towards a Safer TAPPI PEERS Working Towards a Safer Recovery Boiler Operation Speaker Name Month ##, 20## Page 001744 PEERS 2016 Contents Smelt Spout Systems Hood systems Modern hood system improvements Smelt Spout Robot

More information

HOT GAS GENERATOR INSTALLATION, OPERATING AND MAINTENANCE MANUAL

HOT GAS GENERATOR INSTALLATION, OPERATING AND MAINTENANCE MANUAL HOT GAS GENERATOR INSTALLATION, OPERATING AND MAINTENANCE MANUAL SHG 25 SHG 50 SHG 75 SHG 100 SHG 150 SHG 200 SHG 250 SHG 500 SHG 750 SHG 1000 SHG 1500 SHG 2000 SHG 2500 SHG 3000 www.ecostar.com.tr DEAR

More information

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD BURNER MANANGEMENT SYSTEM NXF4000-SPEC AUGUST 5 2017 PRODUCT GUIDE SPECIFICATION FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD GENERAL OVERVIEW 1.1.1. Each burner shall

More information

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C I] WHAT IS INFRARED? Infrared (IR) is a part of electromagnetic spectrum and lies just beyond red color of visible light. Infrared is invisible. However it has properties similar to light i.e. it travels

More information

DUOBLOCK DUAL FUEL (GAS-HEAVY OIL) BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

DUOBLOCK DUAL FUEL (GAS-HEAVY OIL) BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL DUOBLOCK DUAL FUEL (GAS-HEAVY OIL) BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL MODULATING OPERATION ECO 250 ECO 300 ECO 350 ECO 400 ECO 450 ECO 500 ECO 600 ECO 700 ECO 800 ECO 900 www.ecostar.com.tr

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 996 CRAFTSMAN EXAMINATION, NOVEMBER 009 GASFITTING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information