RESIDENTIAL LINE 2018 PRICE BOOK

Size: px
Start display at page:

Download "RESIDENTIAL LINE 2018 PRICE BOOK"

Transcription

1 RESIDENTIAL LINE 2018 PRICE BOOK

2 Table of Contents Effective: July 16, 2018 Supersedes: May 8, 2018 Order Fax Form Available Unit Configurations Series 700A Series 500A Series 506A Series 300A Synergy3D Series 500R11 Indoor Split Series 500R011 Outdoor Split Series SAH Refrigerant Air Handler Envision Hydronic Air Handler Series 500W11 Water to Water Series OptiHeat 504W Envision Large Hydronic Symphony IntelliStart Thermostats IntelliZone Zoning Systems Zoning Dampers HydroLogic Ground Water Accessories (Open Loop) GeoLink Flow Center & Accessories GeoLink Pipe GeoLink Fusion Fittings Environol GeoLink Socket Fusion Tools Installation Accessories & Tools Service Tool Kit Electronic Air Cleaners Humidifiers AlpinePure 411 MERV 11 Filters Disposable Filters Sales & Marketing Materials WaterFurnace Software About Our Warranties Claim Procedures Warranty Buy Up Form Phone Orders: Fax Orders:

3 Order Form: Fax orders to Dealer Name: Ship Date: Account #: Ship Via: Job Name: Ship To: Your P.O. #: Order Date: Shipping Instructions WFI Order #: Item/Part Number Qty Item/Part Number Qty Basic Items Basic Items Unit Coils Thermostat Straight Pipe Auxiliary Heater Elbows Air Pad Tees Air Cleaner Miscellaneous Miscellaneous Closed Loop Accessories Flow Center Connector Kit Adapter Set Replacement Parts Open Loop Accessories Reference Model & Serial Number Well Water Kit Flow Regulator Solenoid Valve Pete's Plugs WaterFurnace International Order Form Fax Orders to Freight Policy effective July 16, 2018: Orders of residential equipment with a net value of $4,500 or more will be charged an $95 freight Orders of residential equipment with a net value of under $4,500 will receive freight items of ppd/add Orders with drop ship items are charged actual freight RSG-002 Rev 5.18 Phone Orders: Fax Orders:

4 Available Unit Configurations Vertical Configurations Topflow Bottomflow Piping Piping End End Left Return Right Return Left Return Right Return Rear Left Return Piping End Right Return Horizontal Configurations Return Options Discharge Options Piping Left Return Piping Right Return Right Return End Discharge Left Return End Discharge Piping Right Return Side Discharge Left Return Side Discharge 4 Phone Orders: Fax Orders:

5 700A11 Variable Speed (3-5 Tons) N V V 036 A C T L 0 J 16 N Model N 7 series Water-to-Air Compressor Type V Variable Speed Cabinet Configuration V Vertical H Horizontal Unit Capacity MBTU s 036,048,060 Vintage A Current Vintage Voltage /60/1 Hot Water Options 0 No Hot Water 1 Hot Water Generation with Factory Installed Pump Blower Motor Options 1 Variable Speed ECM Blower 2 High Static Variable Speed ECM (036 Only) Future Option N - None Controls Option J Aurora Variable Speed Control K Aurora VS Control w/ Performance Monitoring L Aurora Variable Speed Control with UPC 1 M Aurora VS Control w/ Performance Monitoring and UPC 1 Filter Options 0 2 inch MERV11 Filter 1 AlpinePure 411 (Vertical Only) Return Air Configuration L Left R Right Discharge Configuration T Top (Vertical) B Bottom (Vertical) R Rear (Vertical) S Side (Horizontal) E End (Horizontal) Water Coax C Copper N CuproNickel Rev.: 10/4/2017 Notes: 1 UPC is not compatible with Symphony or IntelliZone2 Phone Orders: Fax Orders:

6 Variable Speed Vertical (3-5 Tons) Vertical Unit and Options 1 UPC is not compatible with Symphony or IntelliZone2. Must use ZSUP-H-WFI02 wall sensor. Code Digit Unit Size (Digits 4-6) Series 700A11 - Variable Capacity NVV ,139 16,924 18,279 Vintage Voltage * /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option Variable Speed ECM High Static Variable Speed ECM ,116 Water Coil Option Copper C Cupronickel N Discharge Air Configuration Top T Bottom B Rear R Return Air Configuration Left or Right L or R Filter Option 2 MERV 11 Filter AlpinePure Control Option Aurora Variable Speed Control J Aurora Variable Speed Control with Performance Monitoring K Aurora Variable Speed Control with UPC 1 L Aurora Variable Speed Control with Performance Monitoring with UPC 1 M 15 1,331 1,331 1,331 Future Option None N NOTES: Example Model #: NVV036A111CTL0JN - $16,139 FormiShield Plus coated air coils 7 Series 700A11 unit cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" Energy Monitoring and Refrigeration packages are standard 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance 6 Phone Orders: Fax Orders:

7 Variable Speed Horizontal (3-5 Tons) Horizontal Unit and Options 1 UPC is not compatible with Symphony or IntelliZone2. Must use ZSUP-H-WFI02 wall sensor. Code Digit Unit Size (Digits 4-6) Series 700A11 - Variable Capacity NVH ,970 17,765 18,638 Vintage Voltage * /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option Variable Speed ECM High Static Variable Speed ECM ,116 Water Coil Option Copper C Cupronickel N Discharge Air Configuration End or Side E or S Return Air Configuration Left or Right L or R Filter Option 2 MERV 11 Filter Control Option Aurora Variable Speed Control J Aurora Variable Speed Control with Performance Monitoring K Aurora Variable Speed Control with UPC 1 L Aurora Variable Speed Control with Performance Monitoring with UPC 1 M 15 1,331 1,331 1,331 Future Option None N NOTES: Example Model #: NVH036A111CEL0JN - $17,788 FormiShield Plus coated air coils 7 Series 700A11 unit cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" Energy Monitoring and Refrigeration packages are standard 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Phone Orders: Fax Orders:

8 Accessories: Variable Speed (3-5 Tons) Description Part Number Used with Variable Speed Models Thermostats Communicating Color Touchscreen Thermostat w/energy Monitoring and Humidity Control TPCC32U Communicating Thermostat w/energy Monitoring and Humidity Control TPCM32U04A Pro Zone Wall Sensor w/humidity (use with UPC only) ZSUP-H-WFI Aurora Interface Display Service Tool - NET PRICE (tool warranty applies) AIDK Aurora Touch UPC Kit - LIST PRICE (use with UPC only) ATUK02 2,071 2,071 2,071 Retrofit Control Kits Performance Monitoring Kit 5SPKL-HW Loop Pressure Monitoring Kit LPMK Flow Meter Kit (Open loop low flow applicaitons) FMKS Variable Speed Flow Center High impact polystyrene plastic cabinet, one Grundfos Magna Geo variable speed pump (1 pump flow center) and one UP26-99 fixed speed pump (2nd pump on 2 pump flow center) Vertical Auxiliary Heaters Internal Mount, Electronic Control Board Sequenced Operation 15-20kW include internal fuses Horizontal Auxiliary Heaters Internal mount control box, Coil assembly external mount Electronic Control Board, Sequenced Operation, 15-20kW include internal fuses (Use on Horizontal & Rear Discharge Units) NOTES: 7 Series without UPC must use TPCC32U01, TPCM32U04 or IntelliZone2. No other thermostats will operate the heat pump. 7 Series with UPC must use ZSUP-H-WFI02 wall sensor. FCV1-GL 1,959 1,959 1,959 FCV2-GL 2,369 2,369 2,369 EAL10A EAL15A EAL20A EALH10A EALH15A EALH20A Air Pads for Vertical Topflow Units AP - High density plastic AP APF - 2 PEX foam, cutable APF Electronic Air Cleaner Vertical Units (30x32) EAC Vertical Units (30x36) EAC Bottom Flow Units (30x36) EAC Horizontal Units (20x42) EAC Horizontal Units (20x47) EAC Electrostatic Air Filter Vertical Units (30x32) EAF Vertical Units (30x36) EAF Bottom Flow Units (30x36) EAF Horizontal Units (20x42) EAF Horizontal Units (20x47) EAF UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Aurora Advanced Variable Speed Control Active Dehumidification 'Superboost' cooling mode Energy Monitoring and Refrigeration packages are standard Performance monitoring (optional) Variable Speed Compressor Variable Speed ECM fan motor FormiShield Plus coated coax Electronic expansion valve Internal electric heat (optional on vertical units only) 1" Swivel fittings Gray powder coated heavy gauge galvanized cabinet Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed 8 Phone Orders: Fax Orders:

9 500A11 Single Speed and Dual Capacity (1-6 Tons) N D V 049 H C T L 0 15 A 16 N Model Type N 5 Series Water-to-Air Compressor Type D Dual-Stage S Single Stage Cabinet Configuration V Vertical H - Horizontal Unit Capacity (MBTUH) 012, 018, 022, 026, , 038, 042, 048, , 064, 070, 072 Vintage H , J Voltage /60/1 Hot Water Generation 0 No Hot Water Generation 1 Hot Water Generation with Factory Installed Pump Blower Options 0 PSC (Single Stage Only) 1 Variable Speed ECM 2 High Static Variable Speed ECM ( Only) 3 High Static PSC (022, 030, 036, 042, 048) 4 5-Speed ECM ( ) Notes: All Models include sound kits as std. equipment 1 Available on vertical configurations only 2 Control option not available with PSC motor 3 UPC is not compatible with Symphony or IntelliZone2 IntelliStart & Air Coil Option* N No IntelliStart, Uncoated Coil A IntelliStart, Uncoated Coil B No IntelliStart, AlumiSeal C IntelliStart, AlumiSeal Control Option A Aurora TM Base Control (ABC) B Aurora Advanced Control (ABC & AXB) C Aurora Performance Package ( , ECM Blowers Only) 2 D Aurora Performance and Refrigeration Package ( , ECM Blowers Only) 2 E Aurora TM Base Control w UPC 2,3 F Aurora Advanced Control w UPC 2,3 G Aurora Performance Package w UPC 2,3 H Aurora Performance and Refrigeration Package w UPC 2,3 Filter Option 0 2 inch MERV11 Filter 1 AlpinePure 411 (Vertical Only, ) 1 Return Air Configuration L Left R Right Discharge Air Configuration T Top (Vertical) B Bottom (Vertical) R Rear (Vertical) S Side (Horizontal) E End (Horizontal) Water Coil Option C Copper N CuproNickel Phone Orders: Fax Orders:

10 Single Speed Vertical (1-6 Tons) Vertical Unit and Options Code Digit Unit Size (Digits 4-6) Series 500A11 - Single Capacity NSV 1-3 6,189 6,827 8,246 8,946 9,666 10,272 10,476 11,018 11,753 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option PSC Variable Speed ECM High Static Variable Speed ECM ,116 1,116 1,116 High Static PSC Speed ECM Water Coil Exchanger Copper C Cupronickel N Discharge Air Configuration Top T Bottom B Rear 2 R Return Air Configuration Left or Right L or R Filter Option 2 MERV 11 Filter AlpinePure Control Option Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package 2 C Aurora Performance and Refrigeration Package 2 D Aurora Base Control (ABC) with UPC 2,3 E Aurora Advanced Control (ABC and AXB) with UPC 2,3 F 15 1,275 1,275 1,275 1,275 1,275 1,275 1,275 1,275 1,275 Aurora Performance Package with UPC 2,3 G 15 1,397 1,397 1,397 1,397 1,397 1,397 1,397 1,397 Aurora Performance and Refrigeration Package with UPC 2,3 H 15 1,632 1,632 1,632 1,632 1,632 1,632 1,632 1,632 IntelliStart & Air Coil Option No IntelliStart, Uncoated Coil N IntelliStart, Uncoated Coil A No IntelliStart, AlumiSeal (8 week lead time) B IntelliStart, AlumiSeal (8 week lead time) C ,091 1,091 1 Available on vertical configurations only 2 Control option not available with PSC motor 3 UPC is not compatible with Symphony or IntelliZone2. Must use ZSUP-H-WFI02 wall sensor. NOTES: Example Model #: NSV036*111CTL0AN - $11,130 Stock standard units contain all aluminum air coil 5 Series 500A11 unit cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance 10 Phone Orders: Fax Orders:

11 Single Speed Horizontal (1-6 Tons) Horizontal Unit and Options Code Digit Unit Size (Digits 4-6) Series 500A11 - Single Capacity NSH 1-3 6,375 7,126 8,718 9,421 11,125 11,224 11,382 11,902 13,006 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option PSC Variable Speed ECM High Static Variable Speed ECM ,116 1,116 1,116 High Static PSC Speed ECM Water Coil Option Copper C Cupronickel N Discharge Air Configuration End or Side E or S Return Air Configuration Left or Right L or R Filter Option 2" MERV 11 Filter Control Option Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package 1 C Aurora Performance and Refrigeration Package 1 D Aurora Base Control (ABC) with UPC 1,2 E Aurora Advanced Control (ABC and AXB) with UPC 1,2 F 15 1,275 1,275 1,275 1,275 1,275 1,275 1,275 1,275 1,275 Aurora Performance Package with UPC 1,2 G 15 1,397 1,397 1,397 1,397 1,397 1,397 1,397 1,397 Aurora Performance and Refrigeration Package with UPC 1,2 H 15 1,632 1,632 1,632 1,632 1,632 1,632 1,632 1,632 IntelliStart & Air Coil Option No IntelliStart, Uncoated Coil N IntelliStart, Uncoated Coil A No IntelliStart, AlumiSeal (8 week lead time) B IntelliStart, AlumiSeal (8 week lead time) C ,129 1,129 1 Control option not available with PSC motor 2 UPC is not compatible with Symphony or IntelliZone2. Must use ZSUP-H-WFI02 wall sensor. NOTES: Example Model #: NSH036*111CEL0AN - $12,589 Stock standard units contain all aluminum air coil 5 Series 500A11 unit cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Phone Orders: Fax Orders:

12 Accessories: Single Speed (1-6 Tons) Description Part Number Used with Single Speed Models Wall Sensor for UPC Pro Zone Wall Sensor w/humidity (use with UPC only) ZSUP-H-WFI Aurora Interface Display Service Tool - NET PRICE (tool warranty applies) AIDK Aurora Touch UPC Kit - LIST PRICE (use with UPC only) ATUK02 2,071 2,071 2,071 2,071 2,071 2,071 2,071 2,071 2,071 Retrofit Control Kits (ABC & AXB Required) AXB Kit (Energy Monitoring included) 5SAK Refrigeration Monitoring Kit (5SAK must also be purchased) 5SRK Performance Monitoring Kit (5SAK must also be purchased) 5SPKS-HW Performance Monitoring Kit (5SAK must also be purchased) 5SPKL-HW Loop Pressure Monitoring Kit LPMK Flow Meter Kit (Open loop low flow applications) FMKS Vertical Auxiliary Heaters Internal Mount Electronic Control Board Sequenced Operation 15-20kW include internal fuses EAS4A 479 EAM5A EAM8A EAM10A EAL10A EAL15A EAL20A Horizontal Auxiliary Heaters Internal mount control box EASH4A 487 Coil assembly external mount EAMH5A Electronic Control Board EAMH8A Sequenced Operation EAMH10A kW include internal fuses (Use on Horizontal & Rear Discharge Units) EALH10A EALH15A EALH20A Air Pads for Vertical Topflow Units AP - High density plastic AP AP APF - 2 PEX foam, cutable APF Electronic Air Cleaner Vertical Units (20x24) EAC Vertical Units (24x28) EAC Vertical Units (28x30) EAC Vertical Units (30x32) EAC Vertical Units (30x36) EAC Bottom Flow Units (24x28) EAC Bottom Flow Units (30x36) EAC Horizontal Units (18x32) EAC Horizontal Units (20x37) EAC Horizontal Units (20x42) EAC Horizontal Units (20x47) EAC Electrostatic Air Filter Vertical Units (16x20) EAF Vertical Units (20x24) EAF Vertical Units (24x28) EAF Vertical Units (28x30) EAF Vertical Units (30x32) EAF Vertical Units (30x36) EAF Bottom Flow Units (24x28) EAF Bottom Flow Units (30x36) EAF Horizontal Units (16x20) EAF Horizontal Units (18x32) EAF Horizontal Units (20x37) EAF Horizontal Units (20x42) EAF Horizontal Units (20x47) EAF UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Aurora Base Control Single Speed Scroll Compressor Variable Speed ECM fan motor (optional) 5 Speed ECM fan motor (optional) IntelliStart (optional) All aluminum air coil Optional AlumiSeal coated coil (8 week lead time) Expansion valve 1" Swivel fittings Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed 12 Phone Orders: Fax Orders:

13 Dual Capacity Vertical (2-6 Tons) Vertical Unit and Options Code 1 Must use horizontal auxiliary heaters 2 Control option not available with PSC motor 3 UPC is not compatible with Symphony or IntelliZone2. Must use ZSUP-H-WFI02 wall sensor. Digit Unit Size (Digits 4-6) Series 500A11 - Dual Capacity NDV 1-3 9,749 10,526 11,051 11,915 12,660 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option 5 Speed ECM Variable Speed ECM High Static Variable Speed ECM Water Coil Option Copper C Cupronickel N Discharge Air Configuration Top T Bottom B Rear 1 R Return Air Configuration Left or Right L or R Filter Option 2 MERV 11 Filter AlpinePure Control Option Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package 2 D Aurora Base Control (ABC) with UPC 2,3 E Aurora Advanced Control (ABC and AXB) with UPC 2,3 F 15 1,275 1,275 1,275 1,275 1,275 Aurora Performance Package with UPC 2,3 G 15 1,397 1,397 1,397 1,397 1,397 Aurora Performance and Refrigeration Package with UPC 2,3 H 15 1,632 1,632 1,632 1,632 1,632 IntelliStart & Air Coil Option No IntelliStart, Uncoated Coil N IntelliStart, Uncoated Coil A No IntelliStart, AlumiSeal (8 week lead time) B IntelliStart, AlumiSeal (8 week lead time) C ,091 1,091 NOTES: Example Model #: NDV038*111CTL0AN - $11,551 Stock standard units contain all aluminum air coil 5 Series 500A11 unit cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Phone Orders: Fax Orders:

14 Dual Capacity Horizontal (2-6 Tons) Horizontal Unit and Options Code Digit Unit Size (Digits 4-6) Series 500A11 - Dual Capacity NDH ,197 11,984 12,044 12,870 13,985 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option 5 Speed ECM Variable Speed ECM HIgh Static Variable Speed ECM Water Coil Option Copper C Cupronickel N Discharge Air Configuration End or Side E or S Return Air Configuration Left or Right L or R Filter Option 2 MERV 11 Filter Control Option Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package 1 D Aurora Base Control (ABC) with UPC 1,2 E Aurora Advanced Control (ABC and AXB) with UPC 1,2 F 15 1,275 1,275 1,275 1,275 1,275 Aurora Performance Package with UPC 1,2 G 15 1,397 1,397 1,397 1,397 1,397 Aurora Performance and Refrigeration Package with UPC 1,2 H 15 1,632 1,632 1,632 1,632 1,632 IntelliStart & Air Coil Option No IntelliStart, Uncoated Coil N IntelliStart, Uncoated Coil A No IntelliStart, AlumiSeal (8 week lead time) B IntelliStart, AlumiSeal (8 week lead time) C ,129 1,129 1 Control option not available with PSC motor 2 UPC is not compatible with Symphony or IntelliZone2. Must use ZSUP-H-WFI02 wall sensor. NOTES: Example Model #: NDH038*111CEL0AN- $13,009 Stock standard units contain all aluminum air coil 5 Series 500A11 unit cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance 14 Phone Orders: Fax Orders:

15 Accessories: Dual Capacity (2-6 Tons) Description Part Number Used with Dual Capacity Models Wall Sensor for UPC Pro Zone Wall Sensor w/humidity (use with UPC only) ZSUP-H-WFI Aurora Interface Display Service Tool - NET PRICE (tool warranty applies) AIDK Aurora Touch UPC Kit - LIST PRICE (use with UPC only) ATUK02 2,071 2,071 2,071 2,071 2,071 Retrofit Control Kits (ABC & AXB Required) AXB Kit (Energy Monitoring Included) 5SAK Refrigeration Monitoring Kit (5SAK must also be purchased) 5SRK Performance Monitoring Kit (5SAK must also be purchased) 5SPKS-HW 473 Performance Monitoring Kit (5SAK must also be purchased) 5SPKL-HW Loop Pressure Monitoring Kit LPMK Flow Meter Kit (Open loop low flow applications) FMKS Vertical Auxiliary Heaters Internal Mount Electronic Control Board Sequenced Operation 15-20kW include internal fuses Horizontal Auxiliary Heaters Internal mount control box Coil assembly external mount Electronic Control Board Sequenced Operation 15-20kW include internal fuses (Use on Horizontal & Rear Discharge Units) EAM5A 446 EAM8A 508 EAM10A 519 EAL10A EAL15A EAL20A EAMH5A 462 EAMH8A 535 EAMH10A 558 EALH10A EALH15A EALH20A Air Pads for Vertical Topflow Units AP - High density plastic AP AP APF - 2 PEX foam, cutable APF Electronic Air Cleaner Vertical Units (24x28) EAC Vertical Units (28x30) EAC Vertical Units (30x32) EAC Vertical Units (30x36) EAC Bottom Flow Units (24x28) EAC Bottom Flow Units (30x36) EAC Horizontal Units (18x32) EAC Horizontal Units (20x37) EAC Horizontal Units (20x42) EAC Horizontal Units (20x47) EAC Electrostatic Air Filter Vertical Units (24x28) EAF Vertical Units (28x30) EAF Vertical Units (30x32) EAF Vertical Units (30x36) EAF Bottom Flow Units (24x28) EAF Bottom Flow Units (30x36) EAF Horizontal Units (18x32) EAF Horizontal Units (20x37) EAF Horizontal Units (20x42) EAF Horizontal Units (20x47) EAF UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Aurora Base Control Dual Capacity Scroll Compressor Variable Speed ECM fan motor (optional) 5 Speed ECM fan motor All aluminum air coil Optional AlumiSeal coated coil (8 week lead time) IntelliStart (optional) Expansion valve 1" Swivel fittings Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed Phone Orders: Fax Orders:

16 506A11 Dual Capacity Outdoor Package (2-6 Tons) N D P 049 H C C B 2 16 A 17 N A Model Type N 5 Series Water-to-Air Compressor Type D Dual-Stage Cabinet Configuration P Outdoor Packaged Unit Capacity (MBTUH) 026, 038, 049, 064, 072 Vintage H Internal Factory Use Only Voltage /60/1 Auxiliary Heat 00 - None 05 5Kw (026) 08 8Kw (026) 10 10Kw (026, 038, 049, 064, 072) 15 15Kw (038, 049, 064, 072) 20 20Kw (049, 064, 072) Blower Options 1 Variable Speed ECM 2 High Static Variable Speed ECM (038 Only) Water Coil Option C Copper N CuproNickel Packaging A - Standard Insulation 2-1" Foil Faced Fiberglass 6-1" Closed Cell Foam IntelliStart & Air Coil Option N No IntelliStart, Uncoated Coil A IntelliStart, Uncoated Coil B No IntelliStart, AlumiSeal C IntelliStart, AlumiSeal Control Option A AuroraTM Base Control (ABC) B Aurora Advanced Control (ABC & AXB) C Aurora Performance Package D Aurora Performance and Refrigeration Package Filter Option 2 None Return/Discharge Air Configuration B Bottom (Vertical) S Side (Horizontal) Water Connections/Flow Center B Bottom On/off water valve C Bottom w/fc1-gl Flow Center 1 D Bottom w/fc2-gl Flow Center E Side On/off water valve F Side w/fc1-gl Flow Center 1 G Side w/fc2-gl Flow Center Notes: All Models include sound kits as std. equipment 1 FC1-GL not available in units. Rev.: 9/28/17C Description Part Number Used with Dual Capacity Models Aurora Interface Display Service Tool - NET PRICE (tool warranty applies) AIDK Retrofit Control Kits (ABC & AXB Required) AXB Kit (Energy Monitoring Included) 5SAK Refrigeration Monitoring Kit (5SAK must also be purchased) 5SRK Performance Monitoring Kit (5SAK must also be purchased) 5SPKS-HW 473 Performance Monitoring Kit (5SAK must also be purchased) 5SPKL-HW Loop Pressure Monitoring Kit LPMK Flow Meter Kit (Open loop low flow applications) FMKS Vertical Auxiliary Heaters Internal Mount Electronic Control Board Sequenced Operation 15-20kW include internal fuses Standard 5 day lead time. 16 Phone Orders: Fax Orders: Accessories: Outdoor Package (2-6 Tons) EAM5A 446 EAM8A 508 EAM10A 519 EAL10A EAL15A EAL20A

17 Dual Capacity Outdoor Package (2-6 Tons) Vertical Unit and Options Code Digit Unit Size (Digits 4-6) Series 500A11 - Dual Capacity NDP ,799 11,576 12,101 12,965 13,710 Vintage * Voltage /60/ Auxiliary Heat None Kw (026) Kw (026) Kw (026, 038, 049, 067, 072) Kw (038, 049, 067, 072) Kw (049, 067, 072) Blower Motor Option Variable Speed ECM High Static, Variable Speed ECM (038) Water Coil Option Copper C Curpronickel N Water Flow Control Option Bottom On/off water valve B Bottom w/fc1-gl Flow Center C 13 1,571 1,571 1,571 Bottom w/fc2-gl Flow Center D 13 1,958 1,958 1,958 1,958 1,958 Side On/off water valve E Side w/fc1-gl Flow Center F 13 1,601 1,601 1,601 Side w/fc2-gl Flow Center G 13 1,987 1,987 1,987 1,987 1,987 Return/Discharge Air Configuration Bottom B Side S Filter Option None Controls Option Aurora TM Base Controls (ABC) A Aurora Advanced Control (ABC & AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package D IntelliStart and Air Coil Option No IntelliStart Uncoated Coil N IntelliStart, uncoated Coil A No IntelliStart, AlumiSeal B IntelliStart, AlumiSeal C Insulation 1" Foil Faced Fiberglass " Close Cell Foam ,604 2,604 2,604 2,604 2,604 NOTES: Example Model #: NDP038*1101CBB2BN2- $12,508 5 Series 506A11 unit cabinets are painted Standard 5 day lead time. 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Phone Orders: Fax Orders:

18 300A11 Dual Capacity (2-6 Tons) Model Type L 3 Series Water-to-Air Compressor Type D Dual-Capacity Cabinet Configuration V Vertical H - Horizontal Unit Capacity (MBTUH) 024, 036, 048, 060, 072 Vintage * - Factory Use Only Voltage /60/1 Hot Water Generation 0 No Hot Water Generation 1 Hot Water Generation with Factory Installed Pump Blower Options 4 5 Speed ECM L D V 048 * C T L 2 15 A 16 N IntelliStart & Air Coil Option N No IntelliStart, Uncoated Coil A IntelliStart, Uncoated Coil B No IntelliStart, AlumiSeal C IntelliStart, AlumiSeal Control Option A Aurora TM Base Controls Filter Option 2 Duct Flanges, No Filter 0 1" Filter Rack with 1" MERV 8 Filter 1 1" Filter Rails with 1" MERV 8 Filter Return Air Configuration L Left R Right Discharge Air Configuration T Top (Vertical) S Side (Horizontal) E End (Horizontal) Water Coil Option C Copper N CuproNickel Rev.: 12 June 2014D 18 Phone Orders: Fax Orders:

19 Dual Capacity (2-6 Tons) Unit and Options Code Digit Unit Size (Digits 4-6) Series 300A11 - Dual Capacity LD 1-2 6,234 6,639 7,282 7,991 10,485 Configuration Vertical V Horizontal H Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Blower Option 5 Speed ECM Water Coil Option Copper C Cupronickel N Discharge Configuration Top (Vertical) T End or Side (Horizontal) E or S Air Configuration Left or Right L or R Filter Option Duct Flanges, No Filter Filter Rails, 1" MERV Filter Rack, 1" MERV Control Option Aurora Base Control (ABC) A IntelliStart & Air Coil Option No IntelliStart, Uncoated Coil N IntelliStart, Uncoated Coil A No IntelliStart, AlumiSeal (8 week lead time) B IntelliStart, AlumiSeal (8 week lead time) C ,023 1,023 1,102 NOTES: Example Model #: LDV036A104CTL2AN - $6,639 3 Series cabinets are painted (powder coated) Units with AlumiSeal have a standard 8 week lead time UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant 5 Speed ECM fan motor 3 Series cabinets are painted (powder coated) Dual Capacity Scroll Compressor All Aluminum Air Coil AlumiSeal coated air coil (optional with 8 week lead time) IntelliStart (optional) Expansion valve Optional internal electric heat (vertical only) 1" Swivel fittings AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed Factory computer run test Cupronickel or copper coax heat exchangers Standard 2 Year All Parts and Labor Allowance, 5 Year Refrigeration Components and Labor Allowance Warranties: W2P5R is standard and included in list price Accessories - 2 years parts and labor allowance Optional 5 Year Parts and Labor Allowance Warranties: W5PLU is $1,000 list price add Accessories - 5 years parts and labor allowance Note: All warranties are ENERGY STAR Tier 3 compliant. Phone Orders: Fax Orders:

20 Air Pads for Vertical Units For quieter operation AP - High density plastic APF - 2 PEX foam, cutable Vertical Auxiliary Heaters Internal Mount Electronic Control Board 15-20kW include internal fuses Description Horizontal Auxiliary Heaters Internal mount control box, coil assembly, external mount Electronic Control Board 15-20kW include internal fuses Part Number Accessories: Dual Capacity (2-6 Tons) Used with Dual Capacity Models AP AP APF EAM5A EAM8A EAM10A EAL10A EAL15A EAL20A EAMH5A EAMH8A EAMH10A EALH10A EALH15A EALH20A Field Installed 1" Filter Racks, Must Order With Filter Door Below Vertical 1" Filter Rack 47P803-01RG P798-01RG 79 Note: Filter/Air Cleaner Not Included, Select From Below 47P801-01RG P805-01RG 200 Vertical 1" Filter Rack Door 47P804-01RG 18 47P799-01RG 19 Note: Must Order With Filter Rack Above 47P802-01RG P806-01RG 21 Field Installed 1" Filter Racks, Must Order With Filter Door Below Horizontal 1" Filter Rack 47P812-01RG P814-01RG 104 Note: Filter/Air Cleaner Not Included, Select From Below 47P807-01RG P815-01RG 334 Horizontal 1" Filter Rack Door 47P813-01RG Note: Must Order With Filter Rack Above 47P808-01RG Field Installed 1" Filter Rails, Must Order 2 Each Per Unit (Top & Bottom) Vertical 1" Filter Rails (Order 2 Per Unit) 46P828-96RG 18 46P828-96RG 18 Note: Filter/Air Cleaner Not Included, Select From Below 46P828-97RG Field Installed 1" Filter Rails, Must Order 2 Each Per Unit (Top & Bottom) Horizontal 1" Filter Rails (Order 2 Per Unit) 46P862-01RG 18 46P863-01RG 18 Note: Filter/Air Cleaner Not Included, Select From Below 46P861-01RG P864-01RG 28 Disposable Pleated Filters, 1" MERV8 6 month life (Minimum order qty. 2) Vertical Units (20x24) 59P503B12 30 Vertical Units (24x24) 59P503B27 21 Vertical Units (28x30) 59P503B Vertical Units (30x32) 59P503B21 48 Horizontal Units (18x24) 59P503B07 19 Horizontal Units (18x32) 59P503B23 42 Horizontal Units (20x37) 59P503B Horizontal Units (use 1-20x20) 59P503B02 61 (and 1-20x22) 59P503B24 31 Electronic Air Cleaner Vertical Units (20x24) EAC Vertical Units (24x24) EAC Vertical Units (28x30) EAC Vertical Units (30x32) EAC Horizontal Units (18x32) EAC Horizontal Units (20x37) EAC Horizontal Units (20x42) EAC Electrostatic Air Filter Vertical Units (20x24) EAF Vertical Units (24x24) EAF Vertical Units (28x30) EAF Vertical Units (30x32) EAF Horizontal Units (18x32) EAF Horizontal Units (20x37) EAF Horizontal Units (20x42) EAF Phone Orders: Fax Orders:

21 SDV Water-to-Air (3-6 Tons) S D V 049 * C T L 0 15 S 16 N Model Type S Synergy3D Compressor Type D Dual-Stage Cabinet Configuration V Vertical Unit Capacity (MBTUH) 038, 049, 064, 072 IntelliStart Option & Coil Option N No IntelliStart, Uncoated Coil A IntelliStart, Uncoated Coil B No IntelliStart/ AlumiSeal C IntelliStart/ AlumiSeal Control Option S Standard Microprocessor Filter Option 0 2 inch MERV11 Filter 1 AlpinePure 411 Vintage * Internal factory Use Only Voltage /60/1 Hot Water Generation* 0 No Hot Water Generation 2 HWG w/o factory installed pump Blower Options 1 Variable Speed ECM 2 High Static Variable Speed ECM ( Only) Return Air Configuration L Left R Right Discharge Air Configuration T Top R Rear ( ) Water Coil Option C Both Copper N Both CuproNickel L Source Cupronickel,Load Copper S Source Copper, Load CuproNickel Notes: *The factory installed Hot Water option (hot water generator) does not include a factory mounted circulating pump or temperature control. Kit DPK5 (ordered separately) includes field installed circulator, hot water tank adaptor, temperature limit and installation instructions. Rev.: 2/8/2017 Phone Orders: Fax Orders:

22 SDV Water-to-Air (3-6 Tons) Vertical Unit and Options Code Digit Unit Size (Digits 4-6) Synergy3D Series - Dual Capacity SDV ,455 13,983 14,956 15,112 Vintage * Voltage /60/ Hot Water Generation 1 No Hot Water Generation Hot Water Generation without factory installed pump Does not include circulating pump or temperature controls Fan Motor Options Variable Speed ECM High Static Variable Speed ECM Coaxial Heat Exchanger Copper (Source & Load) C Cupronickel (Source & Load) N Source Cupronickel & Load Copper L Source Copper & Load Cupronickel S Discharge Air Configuration Top T Rear 2 R Return Air Configuration Left or Right L or R Filter Option 2 MERV 11 Filter AlpinePure MERV 11 Filter Control Option Microprocessor S IntelliStart & Coil Option No IntelliStart, Uncoated Coil N IntelliStart, Uncoated Coil A No IntelliStart, AlumiSeal (8 week lead time) B IntelliStart, AlumiSeal (8 week lead time) C ,091 1,091 1 DPK5 must be purchased with the hot water generation option 2 Must use horizontal auxiliary heaters NOTES: Example Model #: SDV038*121CTL0SN - $14,094 Synergy3D cabinets are painted (gray powder coated) Units are shipped with a standard 2" filter rack/duct collar - field convertible to 1" Filter brackets sold separately 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance 22 Phone Orders: Fax Orders:

23 Accessories: SDV Water-to-Air (3-6 Tons) Vertical Auxiliary Heaters Sequenced Operation 15-20kW include internal fuses Description Horizontal Auxiliary Heaters (Rear Discharge Units Only) Sequenced Operation 15-20kW include internal fuses Air Pads for Vertical Units Part Number Used with Dual Capacity Models EAL10A EAL15A EAL20A EALH10A EALH15A EALH20A AP - High density plastic AP APF - 2 PEX foam, cutable APF Electronic Air Cleaners Vertical Units (28x30) EAC Vertical Units (30x32) EAC Vertical Units (30X36) EAC Electrostatic Air Filters Vertical Units (28X30) EAF Vertical Units (30X32) EAF Vertical Units (30X36) EAF Hot Water Generation Pump Kit 1 DPK Hydronic System Accessories Potable Water Diaphragm Expansion Tank (4.4 gallon volume) ETPW Brass Safety Relief Valve 30 PSI (A.S.M.E. rated) SRV Enhanced Air Separator 1 NPT connections EAS Combination Make Up Water Pressure Regulator and Backflow Preventer 1/2 union sweat x NPT connections MWSK Check Valve 1 sweat copper CVS For Hydronic accessories, see Hydronic Price Book 1 Must be purchased with any Synergy3D with hot water generation option UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Premier microprocessor based controls Dual Capacity Scroll Compressor Variable Speed ECM fan motor All aluminum air coils IntelliStart (optional) Expansion valve Internal electric heat (optional except on rear discharge) 1" Swivel fittings Gray powder coated heavy gauge galvanized cabinet Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed Phone Orders: Fax Orders:

24 500R11 Indoor Split Single Speed and Dual Capacity (2-6 Tons) N D Z 049 * C N N 0 A 16 A Model N 5 Series Stage D Dual Capacity S Single Capacity Cabinet Configuration Z Indoor Split Unit Capacity 022, 026, 030, 036, 038, 042, 048, 049, 060, 064, 070, 072 Vintage * - Factory Use Only Voltage /60/1 Hot Water Generation 0 None 1 Hot Water Generation with Factory Installed Pump IntelliStart Option N None A - IntelliStart Controls A Aurora TM Base Control (ABC) B Aurora Advance Control (ABC & AXB) C Aurora Performance Package D Aurora Performance and Refrigeration Package Future Options 0 None Future Options N None Future Options N None Water Coax Option C Copper N CuproNickel Future Option 0 - None Rev.: 17, October Phone Orders: Fax Orders:

25 Indoor Split Single Speed (2-6 Tons) Indoor Split Unit and Options Code Digit Unit Size (Digits 4-6) Series Indoor Split Series - Single Capacity NSZ 1-3 5,245 5,660 6,231 6,312 6,578 6,789 7,422 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation HWG with factory installed pump Future Option None Coaxial Heat Exchangers Copper C Cupronickel N Future Option None N Future Option None N Future Option None Controls Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package D IntelliStart Option None N IntelliStart A NOTES: Example Model # NSZ036*110CNN0AN $7,049 Split cabinets are painted (powder coated) 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Phone Orders: Fax Orders:

26 Indoor Split Dual Capacity (2-6 Tons) Indoor Split Unit and Options Code Digit Unit Size (Digits 4-6) Series Indoor Split Series - Dual Capacity NDZ 1-3 5,827 6,983 7,256 7,466 7,919 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation with factory installed pump Future Option None Coaxial Heat Exchangers Copper C Cupronickel N Future Option None N Future Option None N Future Option None Controls Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package D IntelliStart Option None N IntelliStart A Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Accessories: Indoor Split (2-6 Tons) Description Retrofit Control Kits (ABC and AXB required) Part Number Used with Single Speed Models Used with Dual Capacity Models AXB Kit 5SAK Refrigeration Moniroting Kit (5SAK must also be purchased) Performance Monitoring Kit (5SAK must also be purchased) Performance Monitoring Kit (5SAK must also be purchased) Air Pads AP - High density plastic APF - 2 PEX foam, cutable 5SRK SPKS-HW SPKL-HW AP AP APF APF UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Single or Dual Capacity Scroll Compressor Aurora Base Control IntelliStart (optional) Expansion valve 1" Swivel fittings Powder coated heavy gauge galvanized cabinet Accumulator on all models Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed 26 Phone Orders: Fax Orders:

27 500RO11 Outdoor Split Dual Capacity (2-6 Tons) N D S 049 H 1 0 A C N N 0 A 16 N Model N 5 Series Stage D Dual Capacity Cabinet Configuration S Outdoor Split Unit Capacity 026, 038, 049, 064, 072 Vintage H 026, J 038 Voltage /60/1 Hot Water Generation 0 - None Note: 1 FC1-GL Not Available on Units 2 Performance Package just includes water temperature monitoring. IntelliStart Option N None A - IntelliStart Controls A Aurora TM Base Control (ABC) B Aurora Advanced Control (ABC & AXB) C Aurora Performance Package 2 D Aurora Performance and Refrigeration Package 2 Future Options 0 None Future Options N None Future Options N None Water Coax Option C Copper N CuproNickel Flow Center A None B FC1-GL Flow Center 1 C FC2-GL Flow Center Rev.: 4/13/2018 Phone Orders: Fax Orders:

28 Outdoor Split Dual Capacity (2-6 Tons) Outdoor Split Unit and Options Code Digit Unit Size (Digits 4-6) Series Outdoor Split Series - Dual Capacity NDS 1-3 6,317 7,052 7,334 7,542 7,751 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Flow Center Option None A Flow Center, Single Pump FC1-GL 1 B 10 1,225 1,225 1,225 Flow Center, Dual Pump FC2-GL 1 C 10 1,608 1,608 1,608 1,608 1,608 Coaxial Heat Exchangers Copper C Cupronickel N Future Option None N Future Option None N Future Option None Controls Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package D IntelliStart Option No IntelliStart N IntelliStart A The Flow Center is an accessory mounted by WFI and not considered an internal part for warrany purposes. It will be warranted as an accessory for the term specified by the registered warranty of the unit. NOTES: Example Model # NDS038*10BCNN0AN - $8,277 NDS cabinets are painted (powder coated) 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Accessories: Outdoor Split Dual Capacity (2-6 Tons) Description Part Number List Price Retrofit Control Kits (ABC & AXB Required) AXB Kit (Energy Monitoring Included) 5SAK Refrigeration Monitoring Kit (5SAK must also be purchased) 5SRK Performance Monitoring Kit (5SAK must also be purchased) 11P Mounting Pad Bramec III, 6 x 6 modular construction AP UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Rated for outdoor installation Aurora Base Control Dual Capacity Scroll Compressor IntelliStart (optional) Variable Speed ECM (optional) Expansion valve Powder coated heavy gauge galvanized cabinet Accumulator and crankcase heater on all models Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed 28 Phone Orders: Fax Orders:

29 SAH Air Handler Refrigerant Air Handler SAH 036 * 00 1 A R 1 14 S * Model SAH Series Air Handler Unit Capacity Refrigeration (DX) 022 MBTUH 026 MBTUH 030 MBTUH 036 MBTUH 042 MBTUH 048 MBTUH 060 MBTUH 066 MBTUH Vintage * = Factory Use Only Electric Heat 00 None 05 5kW ( only) No Breakers 10 10kW ( only) No Breakers 15 15kW ( only) with Breakers 20 20kW ( only) with Breakers Build *Factory Use Only Position 1 Multi-position Future Options S Standard Voltage /60/1 Air Coil R Refrigerant Controls/ Motor A Standard/ 5 Speed ECM C Aurora AHB/ Variable Speed ECM 1 TXV 1 Factory Installed Note: To field convert the SAH to bottomflow air discharge. The SAHBCK kit must be ordered separately. Note: Air flow on the 060 and 066 units in the horizontal configurations should be limited to 1900 cfm in cooling mode, or condensate blow off may occur. 1. Only available with Aurora controls in the compressor section. Rev.: 2/27/2017 Refrigerant Coil SR A A 036 C 9 1 Model SR Standard Refrigerant Configuration A - A Coil Coil A - Aluminum Future Option 1 Standard Cabinet C Encased U Uncased Unit Capacity Refrigeration (DX) 026 MBTUH 036 MBTUH 048 MBTUH 060 MBTUH Rev.: 2/28/2017 Phone Orders: Fax Orders:

30 Four Position Air Handler Refrigerant Air Handler and Options Code Digit SAH Air Handler Unit Size (Digits 4-6) Series Air Handler SAH 1-3 2,719 2,764 2,810 2,971 3,156 3,183 3,300 3,525 Vintage Current * Electric Heat 0 kw kw kw kw kw TXV Factory Installed Controls/Motor Standard / 5 speed ECM A Aurora AHB / Variable Speed ECM C Air Coil Refrigerant R Voltage /60/ Future Option Standard S Position Multi-position Future Option Standard A Coil and Options NOTES: Example Model # SAH036A051AR1S11 - $2,965 5 Series SAH unit cabinets are painted (powder coated) Code Digit Unit Size (Digits 5-7) Series A Coil SR ,053 1,097 Configuration A Coil A Coil A Coil A Cabinet Uncased U Encased (Refrigerant) C Future Option Standard Warranty: When ordered with a split unit, Air Handler/ A Coil will carry the same warranty as the split unit. Otherwise, a stand-alone Air Handler/ A Coil has a 18 month part only warranty. Accessories: SAH Air Handler Description Part Number List Price SAH022 SAH026 SAH030 SAH036 SAH042 SAH048 SAH060 SAH066 Vertical Auxiliary Heaters (5 kw - 20 kw) Internal Mount 19P659-01K Electronic Control Board 19P659-02K Sequenced Operation 19P659-03K kW include circuit breaker 19P659-04K Bottom Flow Conversion Kit SAHBCK UNIT FEATURES: Earth Friendly R-410A Refrigerant All aluminum air coil Thermal expansion valve Internal electric heat (optional) Aurora AHB Controls (optional) 5 Speed ECM AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed 30 Phone Orders: Fax Orders:

31 NAH Air Handler Hydronic Air Handler NAH 036 * H Model NAH Hydronic Air Handler Unit Capacity 026 MBTUH 036 MBTUH 048 MBTUH 060 MBTUH Air Coil H Hydronic Motor 1 Variable Speed ECM Disconnect 0 No Breakers Installed (only on 5kW & 10kW Heaters) 1 Breakers Installed (only on 15kW & 20kW Heaters) Vintage * = Factory Use Only Electric Heat 00 None 05 5kW ( only) No Breakers 10 10kW ( only) No Breakers 15 15kW ( only) with Breakers 20 20kW (060 only) with Breakers Note: Kit NAHBC must be ordered to field convert NAH to bottom flow air discharge if the unit is going to be used in cooling. Hydronic Coil NH A C 060 C Model NH Hydronic Coil Configuration A A Coil Coil Cabinet C Encased U Encased Capacity 060 MBTUH Phone Orders: Fax Orders:

32 Hydronic Air Handler Air Handler and Options Code Digit Unit Size (Digits 4-6) Envision Series Air Handler NAH 1-3 5,624 5,794 5,908 6,005 Vintage Current * Electric Heat 0 kw kw kw kw kw Disconnect No Breaker Breaker Motor Variable Speed ECM Air Coil Hydronic (hydronic multiplier applies) H Hydronic NAH Air Handler A Coil and Options Code Digit Unit Size (Digits 5-7) 060 Envision Series A Coil N 1 2,377 Model Type Hydronic (hydronic multiplier applies) H 2 0 Configuration A Coil A 3 0 Coil A Coil C 4 0 Cabinet Uncased U 8 0 Encased (Hydronic) (hydronic multiplier applies) C NOTES: Example Model # NAH036B0501H - $5,806 Envision NAH Series unit cabinets are painted (powder coated) Units all have Variable Speed ECM fan motors Field convertible 4 position cabinet for topflow, downflow, horizontal left and right Units are shipped with a filter rack/duct collar - 1" Model voltage for all units is /60/1 "A" Coils only configurable in upflow and horizontal positions Warranty: When ordered with a water to water unit, Air Handler/ A Coil will carry the same warranty as the water to water unit. Otherwise, a stand-alone Air Handler/ A Coil has a 18 month part only warranty. 32 Phone Orders: Fax Orders: Accessories: Hydronic NAH Air Handler Description Part Number List Price NAH022 NAH026 NAH030 NAH036 NAH042 NAH048 NAH060 Vertical Auxiliary Heaters (5 kw - 20 kw) Internal Mount 19P578-01A Electronic Control Board 19P578-02A Sequenced Operation 19P578-03A kW include circuit breaker 19P Bottom Flow Conversion Kit NAHBC Thermal Insulating Blanket R value = 2 92P Disposable Filters, 1 MERV4 6 month life (Minimum order qty. 12) 59P020B Electronic Air Cleaner 20x24 EAC Electrostatic Air Filter 20x24 EAF UNIT FEATURES: Thermostat Variable Speed ECM controls Variable Speed ECM fan motor FormiShield coated air coil Internal electric heat (optional) Silver powder coated heavy gauge galvanized cabinet AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed

33 500W11 Water to Water (1 1/2-6 Tons) Model N 5 Series Hydronic Heat Pump Compressor Type S Single Speed Cabinet Configuration W Water-to-Water Unit Capacity 018, 025, 040, 050, 060, 075 Vintage * - Factory Use Only Voltage /60/1 Hot Water Option 1 0 No Hot Water Generation 2 Hot Water Generation N S W 050 G 1 0 R C 12 S S 0 A N IntelliStart N None A IntelliStart Controls Option A Aurora Base Controls (ABC) B Aurora Advanced Controls (ABC AXB) C Aurora Performance 3 D Aurora Performance 3 & Refrigeration Future Option 0 Standard Future Option S Standard Future Option S Standard Water Coil Option 2 C Copper N - CuproNickel L Source CuproNickel & Load Copper S Source Copper & Load CuproNickel Reversible Option H Heating Only R Reversible NOTES: 1 Available on 040, 050, 060, and 075 only. Hot water generator requires field installed external pump kit. 2 NSW018 and NSW025 heating only models are available only with copper double wall vented load coax for potable water, and are not designed to be converted to dedicated cooling units. 3 Flow meter for Performance option is shipped with unit, and must be externally field installed. Rev.: 18 January 2016 Phone Orders: Fax Orders:

34 Water to Water ( 1 1/2-6 Tons) Water to Water Unit and Options Code Digit Unit Size (Digits 4-6) Series 500W11 - Single Capacity NSW 1-3 5,874 7,166 7,962 8,936 9,156 9,210 Vintage * Voltage /60/ Hot Water Generation Option No Hot Water Generation Hot Water Generation without factory installed pump Operational Modes Dedicated Heating (Field convertible to cooling only) H Heat Pump (Reversible) R 10 1, Water Coil Exchanger Copper (Source & Load) C Cupronickel (Source & Load) N Source Cupronickel & Load Copper L Source Copper & Load Cupronickel S Future Option Standard S Future Option Standard S Future Option Standard Control Option Aurora Base Control (ABC) A Aurora Advanced Control (ABC and AXB) B Aurora Performance Package C Aurora Performance and Refrigeration Package D IntelliStart Option None N IntelliStart A NOTES: Example Model #: NSW040*10HCSS0AN - $ 7,962 NSW cabinets are painted (powder coated) Non-reversible units are shipped in heating mode Hot water generation requires field installed pump kit, DPK5 NSW018 & NSW025 heating only units use hydronic multiplier 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance 34 Phone Orders: Fax Orders:

35 Description Part Number List Price Retrofit Control Kits (ABC and AXB required) AXB Kit (Energy Monitoring Included) NSWAK Refrigeration Monitoring Kit (NSWAK must also be purchased) 5SRK Performance Monitoring Kit (NSWAK must also be purchased) NSWPKS Performance Monitoring Kit (NSWAK must also be purchased) NSWPKL Circulating Pump Kits Load-side low flow pump kit, 3/4" sweat, composite volute 24S Load-side pump kit, 1 FPT, cast iron volute EWPK Load-side pump kit, 1 FPT, bronze volute EWPK2 1,185 1,185 Load-side pump kit, 1 1/4 FPT, cast iron volute EWPK Low voltage pump signal relay (combined source pumps) 13P003B Water Connection Kits 1" MPT x 1" FPT w/1/4 tap, Load Side W-W (set of 2) MA4FPT /4" MPT x 1 1/4" FPT w/1/4 tap, Load Side W-W (set of 2) MA5FPT Stainless steel hose kit 1 WFI-HKM M Stainless steel hose kit 1 1/4 WFI-HKM M Hot Water Generation Pump Kit Includes 230v 1/25 hp pump and fittings DPK Air Pads AP - High density plastic AP AP APF - 2 PEX foam, cutable APF APF Not for use in 018 and 025 potable water applications Accessories: 500W11 Water to Water (1 1/2-6 Tons) UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Aurora Controls Single Speed Scroll Compressors IntelliStart (optional) Expansion valve Silver powder coated cabinet Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed Phone Orders: Fax Orders:

36 504W11Vapor Injection Hydronic Heat Pump (3-5 Tons) N E W 050 * 1 0 R C 12 S S B S N Model N 5 Series Hydronic Heat Pump Compressor Type E Vapor Injection Cabinet Configuration W Water-to-Water Unit Capacity 040, 050, 066 Vintage * - Factory Use Only Voltage /60/1 Hot Water Option 0 No Hot Water Generation IntelliStart N None A IntelliStart Controls Option B Aurora Advanced Controls Future Option 0 Standard Future Option S Standard Future Option S Standard Water Coil Option C Copper Reversible Option R Reversible H Heating Only Rev.: 06 August 2014D 36 Phone Orders: Fax Orders:

37 Vapor Injection Hydronic Heat Pump (3-5 Tons) Vapor Injection Water to Water Unit and Options Code Digit Unit Size (Digits 4-6) Series 504W11 - Vapor Injection NEW 1-3 9,197 9,457 10,227 Vintage Voltage * 7 A A A /60/ Hot Water Generation Option No Hot Water Generation Operational Modes Dedicated Heating H Reversible R Water Coil Option Copper C Future Option Standard S Future Option Standard S Future Option Standard Control Option Aurora Advanced Control B IntelliStart Option None N IntelliStart A NOTES: Example Model #: NEW040*10RCSS0BN - $9,109 NEW cabinets are painted (powder coated) Non-reversible units are shipped in heating mode 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Accessories: Vapor Injection Hydronic Heat Pump (3-5 Tons) Description Part Number List Price Circulating Pump Kits Load-side pump kit, 1 FPT, cast iron volute EWPK1 576 Load-side pump kit, 1 1/4 FPT, cast iron volute EWPK Low voltage pump signal relay (combined source pumps) 13P003B Water Connection Kits 1" MPT x 1" FPT w/1/4 tap, Load Side W-W (set of 2) MA4FPT /4" MPT x 1 1/4" FPT w/1/4 tap, Load Side W-W (set of 2) MA5FPT Stainless steel hose kit 1 WFI-HKM M0 276 Stainless steel hose kit 1 1/4 WFI-HKM M Hot Water Generation Pump Kit Includes 230v 1/25 hp pump and fittings DPK Air Pads AP - High density plastic AP AP APF - 2 PEX foam, cutable APF UNIT FEATURES: Extended Range operation ( F EWT) Earth Friendly R-410A Refrigerant Aurora Advanced Controls Vapor Injection Compressors IntelliStart (optional) Expansion valve Silver powder coated cabinet Factory computer run test AHRI/ASHRAE/ISO performance certified and UL/ETL safety listed Phone Orders: Fax Orders:

38 NDW Hydronic Heat Pump (8-15 Tons) NDW 120 R 1 8 A B SS 14 * Model NDW Envision Series Hydronic Heat Pump Unit Capacity (MBTUH) 100, 120, 150, 180 Operation R - Reversible Voltage /60/1 (Residential) /60/1 (Commercial) /60/ /60/ /60/3 Vintage * - Factory Use Only Non-Standard Options SS - Standard Water Connections B Back Mounted Connections T Top Mounted Connections IntelliStart TM Option N None A IntelliStart Controls 8 FX10 without Communication, with User Interface 9 FX10 with Open N2 Communication Card with User Interface 0 FX10 with Lonworks Communication Card with User Interface 3 FX10 with BacNet Communication Card with User Interface Rev.: 22 April 2013D 38 Phone Orders: Fax Orders:

39 Dual-Capacity Hydronic Heat Pump (8-15 Tons) Water to Water Unit and Options Code Digit Unit Size (Digits 4-6) Envision Series - Dual Capacity NDW ,941 18,587 19,040 20,007 Operational Modes Heat Pump (Reversible) R Voltage /60/ Unit Controller FX-10 Microprocessor (Stand Alone w/interface 1 ) IntelliStart Option None N IntelliStart A Water Connection Options Back mounted connections B Top mounted connections T Non-standard Options Details Non-Standard SS Vintage * Shipped inside control box to avoid freight damage NOTES: Example Model #: NDW120R18NBSS* - $17,701 NDW cabinets are painted (powder coated) 10 Year Parts and 5 Year Labor Allowance Warranties: W10P5L is standard and included in list price Accessories - 5 years parts and labor allowance Optional 10 Year Parts and 10 Year Labor Allowance Warranties: W10PLU list add $1,000 Accessories - 5 years parts and labor allowance Accessories: Dual-Capacity Hydronic Heat Pump (8-15 Tons) Description Part Number List Price Hose Kits 2 Stainless Steel hose kit, Y-Strainer, ball valves, and end fittings WFI-XYH200-F-24M0-M 1,695 1,695 1,695 1,695 Water Connection Kit Source side OR Load side unit fittings, P/T plugs CKNDW Large Flow Centers 1 Grundfos 3 speed pump (28 feet of head at 50 GPM) FCL ,550 4,550 4,550 4,550 2 Grundfos 3 speed pump (56 feet of head at 50 GPM) FCL ,086 7,086 7,086 7,086 1 Grundfos 3 speed pump (38 feet of head at 50 GPM) FCL ,302 5,302 5,302 5,302 2 Grundfos 3 speed pump (76 feet of head at 50 GPM) FCL ,589 8,589 8,589 8,589 1 Grundfos 3 speed pump (55 feet of head at 50 GPM) FCL ,704 5,704 5,704 5,704 2 Grundfos 3 speed pump (110 feet of head at 50 GPM) FCL ,390 9,390 9,390 9,390 Load-Side Pump (pump and 2 GL fittings) 1 Grundfos 3 speed pump (28 feet of head at 50 GPM) PML ,460 3,460 3,460 3,460 1 Grundfos 3 speed pump (38 feet of head at 50 GPM) PML ,267 4,267 4,267 4,267 1 Grundfos 3 speed pump (55 feet of head at 50 GPM) PML ,720 4,720 4,720 4,720 Large Flow Centers Fittings (sets of 2) 1.5 FPT X 2 GeoLink GL6FPT FPT X 2 GeoLink GL8FPT Flushing Adapter GL-FPL Flow Switch Kit FPS APF - 2 PEX foam, cutable APF This part can be used for both load and source side. 2 kits will need to be purchased for fittings on both sides. 2 Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. UNIT FEATURES: Ultra-compact 25 in. W x 33 in. D x 24 in. H Standard waterlines out the back or front (field convertible via control box) Factory optional top waterlines High efficiency brazed plate heat exchangers High efficiency scroll compressors IntelliStart (optional) Phone Orders: Fax Orders:

40 Symphony Aurora WebLink Description Part Number List Price Aurora WebLink Kit - Wifi enabled comfort system (compatible with 3, 5, and 7 Series Water to Air products) AWLK Water (Sump) Alarm Sensor for Aurora Controls WA Note: If the cable supplied with the AWL is not long enough, you may purchase standard Cat6 Ethernet cable locally or order our part number 11P951-01, 100' Cat6 cable. The maximum Cat6 cable length should be kept to 150' or less. Description Part Number Net Price Aurora Programming TooL Kit - Kit includes 2 - USB drives, Mini USB adapter, 2 - PicKits, Power adapter, Aurora pouch NET PRICE APTK Warranty: 2 year parts only Note: The water alarm sensor is not compatible with 3 Series or 5 Series base controls. AWLK01 WA01 Soft Starter IntelliStart Description Part Number Specification List Price 5 Series & 3 Series 024 IS60RKS 5 Series & Synergy & 3 Series IS60RKL Retrofit kit. Reduces locked rotor amps by 60-70%. Provides quieter unit startup. Protects against low voltage Phone Orders: Fax Orders:

41 Thermostats Features Part Number Heat Stages Cool Stages Communicating ACO MCO Programmable Touchscreen Text Based Fault Flash ComforTalk Dual Fuel Humidity 4-wire Energy Monitoring Used with Units List Price TPCC32U or 7 Series, 3 Series (No Energy Monitoring) 775 TPCM32U03A Series, 3 Series (No Energy Monitoring) 342 TPCM32U04A or 7 Series 444 TP32U Single or dual stage ECM or PSC. Splits with gas furnaces. 342 TP32U Single or dual stage ECM or PSC. Splits with gas furnaces. Humidity control. 444 TP32U Single or dual stage ECM or PSC. Splits with gas furnaces. Replacement of gas furnace with 4 wire control. TP32S Single or dual stage ECM or PSC. Splits with gas furnaces. 233 TP32S Single or dual stage ECM or PSC. Splits with gas furnaces. Humidity control. 262 TP32W Single or dual stage ECM Notes: 7 Series units must use either TPCC32U01 or TPCM32U04A 5 Series with Advanced Controls must use a communicating thermostat in order to view power consumption TP32W03 TP32U03, TP32U04, TP32U05*, TPCM32U03A, TPCM32U04A *Daughter board not pictured TPCC32U01 TP32S01, TP32S02 Thermostat Accessories Thermostats Part Number TPCC32U01 TPCM32U03A TPCM32U04A TP32U03 TP32U04 TP32U05 TP32W03 TP32S01 TP32S02 Description List Price TSU01 Indoor Surface Mount Sensor 38 TSU03 Indoor Flush Mount Sensor 44 TSU02 Outdoor Sensor 30 TSW01 1 Indoor Remote Sensor 88 TSW02 1 Outdoor Sensor 103 TSS01 Wireless Indoor/Outdoor Sensor (averaging only available with TP32S02) 102 RFMS MHz Wireless Transceiver Module 71 PROGS01 Plug-In USB Port Programmer Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. 2 Must be purchased with TSS01 Phone Orders: Fax Orders:

42 24V 8 Wire Zoning System Description Part Number List Price IntelliZone2-24V with MasterStat (only used when no AXB or AHB is present) Non-Communicating Zone System that operates on typical 24VAC outputs Multiple level zone calls communicate exact zone load requirements Controls up to 4 zones w/dual capacity compressor, and 2 w/single-speed compressor Zone sizes as small as 25% of whole house Individual zone selectable economy or comfort mode Four staging options: normal, quicker, faster1 or faster2 for various application scenarios Separate staging options for heating and cooling Kit includes - IntelliZone2-24V conversion board, Intellizone2 relay board, MasterStat, outdoor temperature sensor, and communication harness to connect conversion board and relay board IntelliZone2-24V 1,305 Zone Thermostat Option for any of Zones 2 through 4 Full setback capability with communication to the IntelliZone2-24V system ZoneStat 231 Communicating Thermostat TPCC32U Zone Sensor Thermostat Option for any of Zones 2 through 4 Full setback capability (through the MasterStat only) with communication to the IntelliZone2 24V system TroubleShooting Kit Back plate of the MasterStat with harness to plug into IntelliZone2 relay board for set up and service at the zone panel SensorStat 139 Z2TK 67 Zone Transformer Kit - 208/240V - 24V ZTK Remote Zone Sensor Thermostat Kit Option for an invisible thermostat installation for zones 2-6 and communicates with the IntelliZone2 relay panel. The kit includes the SensorStat-Remote, TSU03 (mud in sensor) and wire nuts. All set point adjustments are made at the MasterStat. SensorStat- Remote-Kit 288 ZoneStat MasterStat ZoneStat SensorStat Notes: The IntelliZone2-24V is the replacement for ZCK4. Description Part Number List Price Communicating Zoning System IntelliZone2 with MasterStat and AXB communication harness Communicating Zone System (Only works with 5 and 7 Series units with advanced controls) Multiple level zone calls communicate exact zone load requirements Controls up to 6 zones w/7 Series Variable Speed units, 4 zones w/dual capacity compressor, and 2 w/single-speed compressor Direct control of Variable Speed ECM fan motor to match needs of the space 6-8 fan speeds on line, up to 12 speeds available Zone sizes as small as 25% of whole house (15% variable speed and 25% dual capacity) Individual zone selectable economy or comfort mode Four staging options: normal, quicker, faster1 or faster2 for various application scenarios Separate staging options for heating and cooling Dehumidification mode lowers airflow in cooling for better dehumidification Power consumption displayed on MasterStat for all 7 Series and 5 Series with Advanced Controls Kit includes - IntelliZone2 relay board, MasterStat, AXB harness, TSU02 IntelliZone2 1,146 ZoneStat MasterStat SensorStat ZoneStat Zone Thermostat Option for any of Zones 2 through 6 Full setback capability with communication to the IntelliZone2 system ZoneStat 231 Communicating Thermostat TPCC32U Zone Sensor Thermostat Option for any of Zones 2 through 6. Full setback capability (through the MasterStat only) with communication to the IntelliZone2 system TroubleShooting Kit Back plate of the MasterStat with harness to plug into IntelliZone2 relay board for set up and service at the zone panel SensorStat 139 Z2TK 67 Zone Transformer Kit - 208/240V - 24V ZTK Remote Zone Sensor Thermostat Kit Option for an invisible thermostat installation for zones 2-6 and communicates with the IntelliZone2 relay panel. The kit includes the SensorStat-Remote, TSU03 (mud in sensor) and wire nuts. All set point adjustments are made at the MasterStat. SensorStat- Remote-Kit Phone Orders: Fax Orders:

43 Rectangular Dampers (3 Wire-- Power Open, Power Close) Rectangular Dampers (2 Wire-- Spring Open, Power Close) Zoning System Accessories 8 High 10 High 8" High 10" High 8" Wide ZDR0808T " Wide 8" Wide ZDR0808T " Wide 10" Wide ZDR0810T " Wide ZDR1010T " Wide ZDR0810T " Wide ZDR1010T " Wide ZDR0812T " Wide ZDR1012T " Wide ZDR0812T " Wide ZDR1012T " Wide ZDR0814T " Wide ZDR1014T " Wide ZDR0814T " Wide ZDR1014T " Wide ZDR0816T " Wide ZDR1016T " Wide ZDR0816T " Wide ZDR1016T " Wide ZDR0818T " Wide ZDR1018T " Wide ZDR0818T " Wide ZDR1018T " Wide ZDR0820T " Wide ZDR1020T " Wide ZDR0820T " Wide ZDR1020T " Wide ZDR0824T " Wide ZDR1024T " Wide ZDR0824T " Wide ZDR1024T Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. Circular Dampers (3 Wire-- Power Open, Power Close) Circular Dampers (2 Wire-- Spring Open, Power Close) 3 - Wire 2 - Wire 6 Round 6 Round 9 Long ZDC06T Long ZDC06T Round 8 Round 10 Long ZDC08T Long ZDC08T Round 10 Round 11 Long ZDC10T Long ZDC10T Round 12 Round 12 Long ZDC12T Long ZDC12T Round 14 Round 14 Long ZDC14T Long ZDC14T Round 16 Round 16 Long ZDC16T Long ZDC16T NOTES: Stock damper models ready for immediate shipment Damper sizes not shown are drop shipped within 5 business days Motors are mounted on rectangular damper "high dimension" Dampers available 2 or 3 wire ZDC Circular from 6 to 16 ZDR Rectangular from 8 x 8 to 14 x 30 1 Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. Phone Orders: Fax Orders:

44 Hydronic Controller Part Number Specification Unit Compatability Hydronic List Price HSC HydroStat - Communicating Controller (1 heat pump only, Aurora controls only) NSW, NEW 292 HZC HydroZone Control Only All 439 HZAB HydroZone Accessory Box (water heater or pump control) All 136 HZ0 HydroZone Control with signal isolation board - 0 Zone (24V only) All 717 HLP2EXPU 2 Zone Expansion Panel - uninsulated All 2,072 HLP4EXPU 4 Zone Expansion Panel - uninsulated All 2,503 HLP2EXPI 2 Zone Expansion Panel - insulated All 2,607 HLP4EXPI 4 Zone Expansion Panel - insulated All 3,073 HLPC3U HydroLogic Control Panel - Combination Systems - Up to 3 Tons - uninsulated SDV 4,692 HLPC6U HydroLogic Control Panel - Combination Systems - Up to 6 Tons - uninsulated SDV 5,476 HLPW3U HydroLogic Control Panel - Water-to-Water Systems - Up to 3 Tons - uninsulated NSW, NEW 5,624 HLPW6U HydroLogic Control Panel - Water-to-Water Systems - Up to 6 Tons - uninsulated NSW, NEW 7,298 HLPC3I HydroLogic Control Panel - Combination Systems - Up to 3 Tons - insulated SDV 6,009 HLPC6I HydroLogic Control Panel - Combination Systems - Up to 6 Tons - insulated SDV 6,914 HLPW3I HydroLogic Control Panel - Water-to-Water Systems - Up to 3 Tons - insulated NSW, NEW 7,517 HLPW6I HydroLogic Control Panel - Water-to-Water Systems - Up to 6 Tons - insulated NSW, NEW 9,217 Radiant Thermostats Part Number Specification Unit Compatability Hydronic List Price TP42H01 Touchscreen Thermostat - 4 heat / 2 cool All 434 TP10H01 Radiant Touchscreen Thermostat - 1 heat / 0 cool All 330 TA10H01 Radiant Thermostat - 1 Heat / 0 Cool All 177 ADPL012 Thermostat Adapter Plate All 38 Warranty: 2 year parts and labor allowance Sensors Part Number Specification Unit Compatability Hydronic List Price 12P Thinset Slab Sensor All 90 12P Concrete/ Outdoor Slab Sensor All 270 Description Part Number Package Quantity GeoTank Geothermal Storage Tank Hydronic List Price Geo Storage Tank 80 Gallon GEO-STORAGE-80 2 each - 1-1/2" side ports, 1 top ports, & 3/4" top ports 2,682 Geo Storage Tank 120 Gallon GEO-STORAGE each - 1-1/2" side ports, 1 top ports, & 3/4" top ports 3,464 Top Element Description Part Number Hydronic List Price GeoTank 80 GeoTank watt/240v 19P watt/240v 19P watt/240v 19P Lower Bung with 1/8 tapped sensor 1 NPSM with 1/8 FPT for sensor 22P Single Element Thermostat 19P NOTE: All GeoStorage tank replacement parts are drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. Geo Storage Tank Parts 44 Phone Orders: Fax Orders:

45 Ground Water Accessories (Open Loop) PPV100/BPV100 Modulating Water Valve FR*HY Description Part Number Specification List Price Plastic Solenoid Valve - 1 FPT w/24 VAC coil PPV100 All (to 6 ton) 115 Brass Solenoid Valve - 1 FPT w/24 VAC coil BPV100 All (to 6 ton) 287 Motorized Solenoid Valve - Slow opening/closing 24VAC coil with 22VA draw V100FPT 1" FPT (up to 12 GPM) 354 Power Head Replacement V100PH For V100FPT 234 Modulating Water Valve Kit (AXB required) Consists of modulating water valve, wire harness, connector wire and instruction manual Flow Regulator Valve 3/4 Brass FPT x FPT 4MWVK 1" Modulating 560 5MWVK 1 1/4" Modulating 677 FR2HY 2 GPM 116 FR3HY 3 GPM 116 FR4HY 4 GPM 116 FR5HY 5 GPM 116 FR6HY 6 GPM 116 FR7HY 7 GPM 116 FR8HY 8 GPM 116 FR9HY 9 GPM 116 FR10HY 10 GPM 116 P/T Port Plug 10A021 1/4 MPT 14 PP1/2 1/2 MPT 25 Flow Meter K713G 3-20 GPM 1 FPT 476 Well Water Kit for single-speed compressor units Consists of a 1 FPT water solenoid valve, three 1 FPT ball isolation valves, 2 P/T plugs, MA4FPT adapter set Well Water Kit for dual capacity compressor units Consists of two 1 FPT water solenoid valves, four 1 FPT ball isolation valves, 2 P/T plugs, MA4FPT adapter set Well Water Kit for variable capacity and dual capacity (with AXB controls) compressor units Consists of three 1 FPT x 1 FPT ball valves, one 1 MPT x 1 FPT adapter set, 1 valve proportional control, 2 P/T plugs WWK2 Single-Speed or 2-Step Scroll 781 WWK3 Dual Capacity 1,046 WWKVS Variable Speed or Dual Capacity with AXB controls Pressure Regulating Valve - 3/4 23P WWK2/WWK A021 PP1/2 Phone Orders: Fax Orders:

46 Flow Center and Accessories FC2 - FPT CK4LI FC2-GL MA4INS GLGH Description FPT Flow Centers and Accessories Pre-assembled with pump(s), 3-way valves with flush ports, internal components injected with foam. Horizontal or vertical mounting capability. FPT and FPTB use brass valves and have 1 FPT connection. 2 Brass adapters with P/T plugs for unit connection, 10 reinforced 1 rubber hose for unit to flow center and two 1 MPT x 1 hose barb for flow center connection Adapter Sets 2 pcs. included in each set MA4SWV GL Flow Centers and Accessories GL4INS GL5INS GL4PES GL5PES MA5PES Fixed Speed Pre-assembled with pump(s), 3-way valves with flush ports, internal components injected with foam. Horizontal or vertical mounting capability. GL features a Die Cast Brass valve and pump volute, high-impact polystyrene cabinet, GL5PES, and uses GeoLink Connection Kits. Variable Speed High impact polystyrene plastic cabinet, one Grundfos Magna Geo variable speed pump (1 pump flow center) and one UP26-99 fixed speed pump (2nd pump on 2 pump flow center) AXB required 2 Brass adapters with P/T plugs for unit connection, 10' reinforced 1" rubber hose for unit to flow center and two 1" GL x 1" hose barb for flow center connection Adapter Sets 2 pcs. included in each set GL-FP Part Number Specification List Price FC1-FPT 1 Grundfos pump 1,148 FC2-FPT 2 Grundfos pumps 1,441 FC1-FPTB 1 1 Grundfos pump w/ stainless steel volute 1,616 FC2-FPTB 1 2 Grundfos pumps w/ stainless steel volute 2,047 CK3LI Unit Connection Kit 3/4 MPT x 1 Insert 278 CK4LI Unit Connection Kit 1 MPT x 1 Insert 294 CK5L 1 1/4" MPT X 1 1/4" hose barb, brass elbow w/ 1/4" P/T plugs 168 MA4INS 1 MPT x 1 Hose barb 100 MA5INS 1 MPT x 1-1/4 Hose barb 109 MA5PES 1 MPT x 1-1/4 IPS PE Fusion 141 MA4FPT 1 MPT x 1 FPT w/1/4 tap, Load Side W-W 116 MA5FPT 1 1/4 MPT X 1 1/4 FPT w/ 1/4 Tap 183 MA8FPT 2 MPT X 2 FPT w/ 1/4 Tap 314 MA4SWV 1 MPT X 1 Swivel Union (Brass) B Unit Connector Insulation Kit 37 FC1-GL 1 Grundfos pump 1,092 FC2-GL 2 Grundfos pumps 1,467 FCV1-GL 1 Grundfos Variable Speed pump 1,959 FCV2-GL 1 Grundfos Variable Speed pump and 1 Grundfos pump 2,369 CK4L-GLI Unit Connection Kit 1 GL x 1 Insert 402 GL4INS 1 GeoLink X 1 hose barb 153 GL5INS 1 GeoLink X 1-1/4 hose barb 142 GL4PES 1 GeoLink X 1 PE Fusion 39 GL5PES 1 GeoLink X 1-1/4 PE Fusion 39 GL-4FPT 1 GeoLink X 1 FPT 107 GL-FP 1 Cam Lever Male Elbow for Flush Port 53 92B Unit Connector Insulation Kit 37 GLGH Garden Hose Adapter for Loop Pump eplacement 76 FCV1 - GL 1 Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. 46 Phone Orders: Fax Orders:

47 Flow Center and Accessories Loop Accessories Description The GeoLink Non-Pressurized FC Reservoir is an accessory that can be added to a standard GeoLink flow center to create a nonpressurized flow center system. The GeoLink Non-Pressurized FC Reservoir consists of a fluid reservoir, two bypass valves and an air-eliminating dip tube inside of a foam-insulated cabinet. The GeoLink LET (Loop Expansion Tank) is used for pressurized loops and minimizes callbacks due to low loop pressure caused by loop expansion. The Geo-Booster active pressurization system uses a small diaphragm pump and rerservoir to maintain between 25 psig and 35 psig pressure on the loop Medium and Large Flow Centers and Accessories Pre-assembled with 3 speed pumps, 2 3-way valves with flush ports, internal components injected with foam with painted metal cover. GL features a Die Cast Brass valve and pump and uses GeoLink Connection Kits. Includes 1 set GL8PESLM. FCM2 2 Brass adapters with P/T plugs for unit connection (2) 8 reinforced 2 in. rubber hose for unit to flow center. Adapter Sets 2 pcs. included in each set Load-Side Pump Includes pump and 2 GL fittings GL x 2 FPT Connection Adapter Sets 2 pcs. included in each set FCL1 FCL2 Part Number FC-Reservoir Specification The Reservoir is made of high impact polystyrene and includes a sealing cap as well as a GL x GL valve coupling adapter and for FPT flow centers a GL x 1 MPT brass adapter. List Price LET Tank size based on maximum 6 ton loop, maintenance free W* Retrofit installations for maintaining loop pressure, or large residential/light commercial in place of an expansion tank FCM Grundfos 3 speed pumps (23 feet of head at 30 GPM) 3,579 FCL Grundfos 3 speed pump (28 feet of head at 50 GPM) 4,550 FCL Grundfos 3 speed pumps (56 feet of head at 50 GPM) 7,086 FCL Grundfos 3 speed pump (38 feet of head at 50 GPM) 5,302 FCL Grundfos 3 speed pumps (76 feet of head at 50 GPM) 8,589 FCL Grundfos 3 speed pump (55 feet of head at 50 GPM) 5,704 FCL Grundfos 3 speed pumps (110 feet of head at 50 GPM) 9,390 CK5L-XL CK5L, 2-8' 1 1/4"" rubber hose, pair 1 1/4"" hose barb x 1 1/4 XL style fittings, steel hose clamps CK5L-XLS CK5L-XL and 1 1/4" bronze strainer 980 CK8L-GLS Unit Connector Kit with Strainer 2 XL x 2 Insert 2,050 CK8L-GL 2 Unit Connector Kit 2 XL x 2 Insert 1,633 GL5PESLM 2 GeoLink X 1-1/4 PE Fusion 165 GL6PESLM 2 GeoLink X 1-1/2 PE Fusion 165 GL8PESLM 2 GeoLink X 2 PE Fusion 165 GL6FPT 1 2 GeoLink X 1 1/2 FPT 268 GL8FPT 1 2 FPT x 2 GeoLink 268 GL-FPL Flushing Adapters 2 GL x 1 Cam Lever 226 GL-GHL 2 GeoLink Garden Hose Adapter for Pump Replacement 141 PML Grundfos 3 speed pump (28 feet of head at 50 GPM) 3,460 PML Grundfos 3 speed pump (38 feet of head at 50 GPM) 4,267 PML Grundfos 3 speed pump (55 feet of head at 50 GPM) 4,720 MA8FPT 2 MPT x 2 FPT w/1/4 tap, Load Side W-W 314 GL8FPT 1 2 FPT x 2 GeoLink Rubber Hose - 1 rubber hose for connection from unit to flow center RH of 1 Rubber hose 275 Flow Center Replacement Parts 24P002A03 Grundfos pump for FC1 & FC2 403 MAGNA3 Pumps RMFCV1-2GL Grundfos variable speed pump for FCV 1,356 GLBPK Blank off plate for pump (GL Flow Center) 38 FPTBPK Blank off plate for pump (FPT Flow Center) 89 24P507A01 1 E-coat cast volute 99 M3S BC 1 MAGNA3 variable speed pump, w/o check valve (up to 80 GPM) 4,950 M3C BC 1 MAGNA3 variable speed pump, w/check valve (up to 80 GPM) 5,570 M3S BC 1 M3C BC 1 M3S BC 1 M3C BC 1 MAGNA3 variable speed pump, w/o check valve (up to 110 GPM) MAGNA3 variable speed pump, w/check valve (up to 110 GPM) MAGNA3 variable speed pump, w/o check valve (up to 110 GPM) MAGNA3 variable speed pump, w/check valve (up to 110 GPM) MAGNA3 Relay MAGNA3RELAY 1 Allows up to 5 units to share a MAGNA3 pump 288 MAGNA3 Insulated Flush Port FPL8 1 2" insulated flush port (GL8 adapter sets required) 791 5,455 6,075 7,509 8,129 1 Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. Phone Orders: Fax Orders:

48 Non-Pressurized Flow Center and Accessories FC1-GLNP FCV1-GLNP Description Non-Pressurized Flow Centers and Accessories Fixed Speed Pre-assembled with Grundfos UP26-99 pump(s) with epoxy coated cast iron pump volute, 3-way composite valves with flush ports, metal cabinet, internal components injected with foam and uses GeoLink connection kits (CKNP-GL4I or GL5PVC not included). Vertical mounting only. Fixed Speed Pre-assembled with Grundfos UP26-99 pump(s) with epoxy coated cast iron pump volute, 3-way composite valves with flush ports, metal cabinet, internal components injected with foam and uses GeoLink connection kits (CKNP-GL4I or GL5PVC not included). Vertical mounting only. For two unit installation. Variable Speed Pre-assembled with one Grundfos Magna Geo variable speed pump (1 pump flow center) and one UP26-99 pump (2nd pump on 2 pump flow center), 3-way composite valves with flush ports, metal cabinet, internal components injected with foam and uses GeoLink connection kits (CKNP-GL4I or GL5PVC not included). Vertical mounting only. AXB required. Variable Speed Pre-assembled with a combination of Grundfos Magna Geo variable speed pump and UP26-99 fix speed pump, 3-way composite valves with flush ports, metal cabinet, internal components injected with foam and uses Geo- Link connection kits (CKNP-GL4I or GL5PVC not included). Vertical mounting only. AXB required. For two unit installation. Installation kit for connecting a GLNP flow center to 1-1/4 HDPE pipe. Kit included 2 brass elbow adapters with P/T plugs for unit connection, 12 reinforced 1 rubber hose for unit to flow center, 3 way valve for service, two 1 GL x 1 hose barb elbows for flow center connection, 1 GL x 1 hose barb, 1-1/4 PE fusion x 1-1/4 GL, 1 PE fusion x 1 hose barb, and fitting insulation kit. Part Number Specification List Price FC1-GLNP 1 Grundfos pump, 3 way composite valves 1,414 FC2-GLNP 2 Grundfos pumps, 3 way composite valves 1,753 FC2-GLNPD 1 2 Grundfos pumps 3,500 FC3-GLNPD 1 3 Grundfos pumps 3,883 FC4-GLNPD 1 4 Grundfos pumps 4,265 FCV1-GLNP FCV2-GLNP FCV2A-GLNPD 1 1 Grundfos Variable Speed pump, 3 way composite valves 1 Grundfos Variable Speed pump and 1 Grundfos pump, 3 way composite valves 1 Grundfos Variable Speed, 1 Grundfos Fixed Speed pumps 2,402 2,727 3,929 FCV2B-GLNPD 1 2 Grundfos Variable Speed pumps 5,262 FCV3C-GLNPD 1 2 Grundfos Variable Speed, 1 Grundfos Fixed Speed pumps 5,591 CKNP-GL4I Unit Connection Kit 1" GL x 1" Insert 591 Adapter Sets (2 pcs. included) GL5PVC PVC adapter set - 1" GL x 1-1/4" PVC 76 Non-Pressurized Flow Center Tools MFMT Mechanical (variable area) flow meter tool 1,088 ABDFMT Adapter kit for B&D flow meter tool Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. MFMT MFMT FC2-GLNPD CKNP-GL4I GL5PVC ABDFMT 48 Phone Orders: Fax Orders:

49 Polyethylene Pipe U-bend Coils SPECIFICATIONS: All pipe and heat fused materials are manufactured from virgin high density, polyethylene 3408 material manufactured according to ASTM D-2513 sections 4.1 and 4.2. Pipe shall be manufactured to outside diameters, wall thickness, and respective tolerances as specified in ASTM D-3035, D-2447, F-714. The pipe shall be able to withstand 160 psig working pressure at 73.4 F in the field. The material shall be 1,600 psi hydrostatic design basis at 73.4 F per ASTM D PE 3408 shall have a cell classification of PE345434C as specified in ASTM D Part Number Description Length List Price GP3C1 1 3/4 IPS, SDR11, COIL GP3C150 3/4 IPS, SDR11, COIL GP3C150U 3/4 IPS, SDR11, U-BEND COILS 2 x GP3C2 3/4 IPS, SDR11, COIL GP3C200U 3/4 IPS, SDR11, U-BEND COILS 2 x GP3C250 3/4 IPS, SDR11, COIL GP3C250U 3/4 IPS, SDR11, U-BEND COILS 2 x GP3C3 3/4 IPS, SDR11, COIL GP3C300U 3/4 IPS, SDR11, U-BEND COILS 2 x GP3C4 3/4 IPS, SDR11, COIL GP3C5 3/4 IPS, SDR11, COIL GP3C6 3/4 IPS, SDR11, COIL GP3C8 3/4 IPS, SDR11, COIL GP3L1 3/4 IPS, SDR11, STRAIGHT 5 x GP4C IPS, SDR11, COIL GP4C150U 1 1 IPS, SDR11, U-BEND COILS 2 x GP4C2 1 IPS, SDR11, COIL GP4C200U 1 1 IPS, SDR11, U-BEND COILS 2 x GP4C IPS, SDR11, COIL GP4C250U 1 1 IPS, SDR11, U-BEND COILS 2 x GP4C3 1 IPS, SDR11, COIL GP4C300U 1 1 IPS, SDR11, U-BEND COILS 2 x GP4C5 1 IPS, SDR11, COIL GP4C6 1 IPS, SDR11, COIL GP4L1 1 IPS, SDR11, STRAIGHT 5 x GP5C1 1-1/4 IPS, SDR11, COIL GP5C2 1-1/4 IPS, SDR11, COIL GP5C200U 1 1-1/4 IPS, SDR11, U-BEND COIL 2 x GP5C3 1-1/4 IPS, SDR11, COIL GP5C300U 1 1-1/4 IPS, SDR11, U-BEND COIL 2 x 300 1,288 GP5C5 1-1/4 IPS, SDR11, COIL 500 1,023 GP5L1 1-1/4 IPS, SDR11, STRAIGHT 5 x GP6C5 1-1/2 IPS, SDR11, COIL 500 1,333 GP6L /2 IPS, SDR11, COIL 5 x GP8C1 1 2 IPS, SDR11, COIL GP8C2 2 IPS, SDR11, COIL GP8C3 1 2 IPS, SDR11, COIL 300 1,249 GP8C5 2 IPS, SDR11, COIL 500 2,081 GP8L1 2 IPS, SDR11, STRAIGHT 5 x Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. Quantities of 50 coils or more, contact factory for speical pricing GEOLINK PIPE FEATURES: 55 year limited warranty Designed for connection by socket or butt fusion Internal banding for easy handling and control Straight pipe is packaged 5-20 ft. lengths per bundle U-BEND NOTE: Includes extra length for connection Phone Orders: Fax Orders:

50 Polyethylene Fusion Fittings Description Part Number Specification List Price Fusion Coupling PIC33 Fusion Coupling - 3/4 x 3/4 8 PIC43 Fusion Coupling - 1 x 3/4 20 PIC44 Fusion Coupling - 1 x 1 12 PIC53 Fusion Coupling - 1-1/4 x 3/4 19 PIC54 Fusion Coupling - 1-1/4 x 1 21 PIC55 Fusion Coupling - 1-1/4 x 1-1/4 12 PIC65 Fusion Coupling - 1-1/2 x 1-1/4 71 PIC66 Fusion Coupling - 1-1/2 x 1-1/2 20 PIC85 Fusion Coupling - 2 x 1-1/4 17 PIC33 PIC86 Fusion Coupling - 2 x 1-1/2 32 PIC88 Fusion Coupling - 2 x 2 14 Fusion Elbows PIE33 Fusion Elbow - 3/4 x 3/4 19 PIE33S Fusion Elbow - 3/4 x 3/4 (Street) 14 PIE33U Fusion Elbow - 3/4 x 3/4 (Short) 16 PIE44 Fusion Elbow - 1 x 1 17 PIE44U Fusion Elbow - 1 x 1 (Short) 11 PIE53 Fusion Elbow - 1-1/4 x 3/4 11 PIE55 Fusion Elbow - 1-1/4 x 1-1/4 15 PIE33S & U PIE55F Fusion Elbow - 1-1/4 x 1-1/4 (45 Degree) 16 PIE55S Fusion Elbow - 1-1/4 x 1-1/4 (Street) 19 PIE55U Fusion Elbow - 1-1/4 x 1-1/4 (Short) 17 PIE66 Fusion Elbow - 1-1/2 x 1-1/2 30 PIE88 Fusion Elbow - 2 x 2 35 Fusion Tee PIT333 Fusion Tee - 3/4 x 3/4 x 3/4 13 PIT444 Fusion Tee - 1 x 1 x 1 19 PIT533 Fusion Tee - 1-1/4 x 3/4 x 3/4 15 PIT544 Fusion Tee - 1-1/4 x 1 x PIT553 Fusion Tee - 1-1/4 x 1-1/4 x 3/4 15 PIT554 Fusion Tee - 1-1/4 x 1-1/4 x PIT555 Fusion Tee - 1-1/4 x 1-1/4 x 1-1/4 23 PIT644 Fusion Tee - 1-1/2 x 1 x PIT664 Fusion Tee - 1-1/2 x 1-1/2 x PIT666 Fusion Tee - 1-1/2 x 1-1/2 x 1-1/2 31 PIT853 Fusion Tee - 2 x 1-1/4 x 3/4 125 PIT854 Fusion Tee - 2 x 1-1/4 x PIT333 PIT855 Fusion Tee - 2 x 1-1/4 x 1-1/4 146 PIT883 Fusion Tee - 2 x 2 x 3/4 27 PIT884 Fusion Tee - 2 x 2 x PIT885 Fusion Tee - 2 x 2 x 1-1/4 27 PIT888 Fusion Tee - 2 x 2 x 2 45 Fusion Header PIH53-3 Fusion Header - 1-1/4 x (3) 3/4 66 PIH53-4 Fusion Header - 1-1/4 x (4) 3/4 87 PIH53-5 Fusion Header - 1-1/4 x (5) 3/4 109 PIH53-4 PIH53-6 Fusion Header - 1-1/4 x (6) 3/ Phone Orders: Fax Orders:

51 Polyethylene Fusion Fittings PIE34A PIC34A Description Part Number Specification List Price Fusion End Cap PICP3 Fusion End Cap - 3/4 16 PICP3 PICP4 Fusion End Cap PICP5 Fusion End Cap - 1-1/4 12 PICP6 Fusion End Cap - 1-1/2 13 PICP8 Fusion End Cap Fusion Ball Valve PIV33 Fusion Ball Valve - 3/4 x 3/4 161 Fusion x MPT Brass. Fusion Tee with P/T Plug Port Adapter Tee Fusion to Thread Coupling (Swivel) PIV44 Fusion Ball Valve - 1 x PIA33 Fusion x Brass Threads - 3/4 x 3/4 MPT 37 PIA44 Fusion x Brass Threads - 1 x 1 MPT 54 PIA54 Fusion x Brass Threads - 1-1/4 x 1 MPT 52 PIA55 Fusion x Brass Threads - 1-1/4 x 1-1/4 MPT 87 PIA66 Fusion x Brass Threads - 1-1/2 x 1-1/2 MPT 105 PIA88 Fusion x Brass Threads - 2 x 2 MPT 116 PIT332A Tee - 3/4 Fusion x 3/4 Fusion x 1/2 FPT for P/T 23 PIT442 Tee -1 Fusion x 1 Fusion x 1/2 FPT for P/T 36 PIT432A Adapter Tee -1 MPT x 3/4 Fusion x 1/2 FPT 60 PIT442A Adapter Tee -1 MPT x 1 Fusion x 1/2 FPT 72 PIC34A Threaded Coupling (Swivel) - 3/4 Fusion x 1 MPT 34 PIC44A Threaded Coupling (Swivel) - 1 Fusion x 1 MPT 60 Fusion to Thread Elbow PIE34A Threaded Elbow - 3/4 Fusion x 1 MPT 35 PIE44A Threaded Elbow - 1 Fusion x 1 MPT 39 Loop Expansion Tank LET 1-1/4 Socket Fusion, 3/4 gallon capacity 289 LET PIV44 PIA33 PIT332A Earth Loop Antifreeze Part Number Specification List Price EN1-D 55 Gallon Drum - Environol 1000 Premix 1,676 EN2-P 5 Gallon Pail - Environol 2000 Pure 344 EN2-D 55 Gallon Drum - Environol 2000 Pure 2,040 NOTES: Environol is drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. Minimum order quantity for EN2-P is 5 pails. Check with your Customer Service Representative regarding transportation charges, freight is an additional charge. UNIT FEATURES: Environmentally safe Biodegrades more readily than any other antifreeze type Mixes easily and completely in water for fast installation Lowest NFPA health warning available (Health-0) Available in both pure (Environol 2000) and premixed ready-to-use (Environol 1000) formulas Available in 5 gallon pail or 55 gallon drums Each Phone Orders: Fax Orders:

52 Socket Fusion Tools Description Part Number Specification List Price Heating Tool FHVT48 Heat Fusion Tool 1,203 FHVTD48 Heat Fusion Tool/Double Mount 1,438 Fuse 19P529A01 Extra Fuse 24 Socket Faces - IPS PTSF3 3/4 IPS Set 224 PTSF4 1 IPS Set 224 PTSF5 1-1/4 IPS Set 224 PTSF6 1-1/2 IPS Set 224 PTSF8 2 IPS Set 224 Cold Rings - IPS PTCR3 3/4 IPS 298 PTCR4 1 IPS 298 PTCR5 1-1/4 IPS 298 PTCR6 1-1/2 IPS 298 PTCR8 2 IPS 298 Depth Gauge/Chamfer Tool - IPS PTDC3 3/4 IPS - Depth Gauge/Chamfer Tool 135 PTDC4 1 IPS - Depth Gauge/Chamfer Tool 135 PTDC5 1-1/4 IPS - Depth Gauge/Chamfer Tool 135 PTDC6 1-1/2 IPS - Depth Gauge/Chamfer Tool 135 PTDC8 2 IPS - Depth Gauge/Chamfer Tool 135 Accessories FHTBL Tool Box 179 FHFT Complete Fusion Tool Set (3/4 in. and 1-1/4 in.) FTS35 FHFT Fusion Timer 144 T490/500 Templesticks - PE 117 FHHB Fusion Tool Cover 84 PTKC5 PE Ratchet Cutter - fits up to 1-1/4 237 PTKC8 PE Ratchet Cutter - fits up to 2.00" 439 PTDCRB Replacement Blade for Chamfer Tool 57 Heating tool w/cover, socket faces, cold rings, 1-1/4 chamfer tool, tool box, timer, temple sticks, 1-1/4 ratchet cutter 2,758 FHVTD48 PTFH8 PTKC5 52 Phone Orders: Fax Orders:

53 July 2018 Installation Accessories and Service Tools Description Part Number Aurora Interface Display Service Tool AIDK GEOTHERMALSTK Includes DPT160, PG100, GA125 99P247A01, LP1, CAMT, 11P538A01, 11P538A DPT160 Digital thermometer 83 DT7106T Digital 6 pt. thermometer (use type T wire) 884 W100T Type T wire (100 ) 95 PG PSI pressure gauge 1/4 MPT 42 GA125 Pressure gauge to P/T port adapter 38 CAMT Alcohol specific gravity hydrometer 62 Earth Loop Flushing System LFC-ETL High volume, high head, self-priming pump, quick connect hoses, heavy duty design, mounted on cart. Includes FPT-GL and GL-FP. Flush Cart Filter Bag LFC-F100M 100 Micron filter bag 35 LFC-F1M 1 Micron filter bag 35 FPT-GL FPT to GL fitting for FPT flow center 51 GL-FP 1 Cam Lever Male Elbow for Flush Port 53 LP1 Fixture to pressurize loop through P/T plug. Garden hose thread to port adapter. Assembly required. 100 GDT Geothermal piping tape (1000 roll). To be buried over the loop header and supply/return lines 292 Flow center 3-way valve wrench 30 Temperature Measurement Pressure Measurement Antifreeze Testing Flushing Adapter Loop Pressurizer Geothermal Piping Tape 99P247A01 Flow Center Wrench Cooling Tower 1 List Price Handheld Aurora Control diagnostic tool with case Service Tool Kit CT096 Specification 1 CT096 1 Included 1/2 hp 115/230 volt pump, pre-plumbed cart 96,000 Btu capacity 4,553 2,326 Net Price, no multiplier applies AIDK01 PG100 LP1 LFC-ETL GA125 DT7106T Service Tool Kit 99P247A01 Phone Orders: Fax Orders:

54 Service Tool Kit Premier Control Service Kit Part Number List Price Aurora Control Service Kit Part Number List Price Includes the following replacement parts: SKP 1,820 Includes the following replacement parts: SKA 2,571 2 Pole Contactor 13P004A03 Aurora Board (ABC) 17P VA Transformer 15P501B01 Aurora AXB Board 17P Main Logic Board 17P Compressor Harness 11P Compressor Harness 11P Low Voltage Harness 11P Low Voltage Harness 11P607B03 Aurora Wire Harness 11P Blower Harness 11P585B03 Freeze Protection Sensor 12P Freeze Protection Thermistor 12P505B03 2 Pole Contactor 13P004A03 Hot Water Limit Sensor 12P VA Transformer 15P501B01 Hot Water Thermistor 12P505B02 Hot Water Thermistor 12P Low Voltage Harness 11P High Pressure Switch SKHPE600 ECM 1/2 HP Module PMK550 Low Pressure Switch SKLPE40 ECM 1 HP Module PMK551 ECM Blower Wires -Horizontal High Voltage 11P585B04 High Pressure Switch SKHPE600 ECM Blower Wires - Horizontal Low Voltage 11P Low Pressure Switch SKLPE40 Loop Pump 24P002A03 NOTE: Does not include any EW replacement parts. Thermostat ECM 1/2 HP Module ECM 1 HP Module TP32U03 PMK542 PMK544 Variable Speed Service Kit Part Number List Price Includes the following replacement parts: SKV 2,722 ABC Variable Speed Control Board 17X EEV Control Board 17P High Pressure Transducer Kit - 7 Series Low Pressure Transducer Kit - 7 Series AKS21 RTD Temperature Sensor - Discharge Temp "AKS11 RTD Temperature Sensor - LAT, EWT, Suction Line, Ambient Temp" Communicating Thermostat with Humidity SK7SHPT SK7SLPT 12P P TPCM32U04 FP2 Sensor 12P Thermistor - LLT (Heating) 12P Thermistor - Yellow FP1 12P ECM EON Module 1/2 HP (036) ECM EON Module 1 HP (048) ECM EON Module 1 HP (060) PMK545 PMK546 PMK Phone Orders: Fax Orders:

55 Electronic Air Cleaners Replacement Media RM3 includes 3 replacement media. Part Number List Price RM RM RM RM RM RM RM RM RM RM RM RM Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. 2 week lead time Humidifiers Desert Spring Humidifier 100% Water Efficient Humidifier is mounted on return air duct Uses very little energy Long life cleanable media 1 year parts only Warranty Description Part Number List Price HUM-KIT 656 HUM-KIT Phone Orders: Fax Orders:

56 411 MERV 11 Filter System Description Alpine Pure MERV 11 Filter System Deluxe filter system with slot for 4 MERV11 filter and 1 slot for optional carbon filter. MERV11 is the highest efficiency pleated filter available for traditional full airflow applications. MERV 11 filter is included. 7 Series Models Part Number List Price Vertical Units (30 x 31.5 x 4 MERV 11) AP411-4RG Vertical Units (30 x 31.5 x 4 MERV 11) AP411-6RG 514 Bottom Flow Units (30 x 31.5 x 4 MERV 11) AP411-6RG Series Models Vertical Units (24 x 27.5 x 4 MERV 11) AP411-2RG 404 Vertical Units (24 x 27.5 x 4 MERV 11) AP411-3RG 471 Vertical Units (30 x 31.5 x 4 MERV 11) AP411-4RG 439 Vertical Units (30 x 31.5 x 4 MERV 11) AP411-6RG 514 Bottom Flow Units (24 x 27.5 x 4 MERV 11) AP411-2RG 404 Bottom Flow Units (30 x 31.5 x 4 MERV 11) AP411-6RG Synergy 3D Models Vertical Units (24 x 27.5 x 4 MERV 11) AP411-3RG 471 Vertical Units (30 x 31.5 x 4 MERV 11) AP411-4RG 439 Vertical Units (30 x 31.5 x 4 MERV 11) AP411-6RG 514 Alpine Pure 411 Replacement Media month life - Shipped in pairs Description Part Number List Price Replacement Media 24 x 27.5 x 4 MERV11 fits AP411-2 and -3 (qty 2) RM-AP Replacement Media 30 x 31.5 x 4 MERV11 fits AP411-4 and -6 (qty 2) RM-AP Alpine Pure Carbon Filter - 3 month life - Shipped in pairs Filter Media 24 x 27.5 x 1 CARBON fits AP411-2 and -3 (qty 2) RM-AP411-23C Filter Media 30 x 31.5 x 1 CARBON fits AP411-4 and -6 (qty 2) RM-AP411-46C Alpine Pure Drain Pan Treatment- 2-6 ton/3-6 month avg life Unit quantity of 1 APDPT 32 Alpine Pure HEPA Filter HEPA replacement filter AP65-502R 590 Alpine Pure HRV Accessories Bathroom Switch/Timer-- Provides high speed ventilation for 20 minutes (for units built AFTER 6/29/10) AP99-20M01 98 Weatherhoods (2)-- 6 with 1/4 mesh screen, hinged AP Tech Grille 4 AP Drop shipped from vendor. Does not include freight. Drop shipped items are non returnable. 56 Phone Orders: Fax Orders:

57 Disposable Filters 7 Series 700A11 Description Disposable Pleated Filters, 2 MERV 11 6 month life (Minimum order qty. 2) Part Number List Price Vertical Units (30x32) 59P Vertical Units (30x36) 59P Bottom Flow (30x36) 59P Horizontal Units (20x20) 59P Horizontal Units (20x22) 59P Horizontal Units (20x25) 59P Disposable Pleated Filters, 2 MERV 13 6 month life. (Minimum order qty. 2) Vertical Units (30x32) 59P Vertical Units (30x36) 59P Bottom Flow (30x36) 59P Horizontal Units (20x20) 59P Horizontal Units (20x22) 59P Horizontal Units (20x25) 59P Series 500A11 Description Disposable Pleated Filters, 2 MERV 11 6 month life (Minimum order qty. 2) Part Number Vertical Units (16x20) 59P Vertical Units (20x24) 59P List Price Vertical Units (24x28) 59P Vertical Units (28x30) 59P Vertical Units (30x32) 59P Vertical Units (30x36) 59P Bottom Flow (24x28) 59P Bottom Flow (30x36) 59P Horizontal Units (16x20) 59P Horiztonal Units (18x24) 59P Horizontal Units (18x32) 59P Horizontal Units (20x37) 59P Horizontal Units (20x20) 59P Horizontal Units (20x22) 59P Horizontal Units (20x25) 59P Disposable Pleated Filters, 2 MERV 13 6 month life. (Minimum order qty. 2) Vertical Units (16x20) 59P Vertical Units (20x24) 59P Vertical Units (24x28) 59P Vertical Units (28x30) 59P Vertical Units (30x32) 59P Vertical Units (30x36) 59P Bottom Flow (24x28) 59P Bottom Flow (30x36) 59P Horizontal Units (16x20) 59P Horiztonal Units (18x24) 59P Horizontal Units (18x32) 59P Horizontal Units (20x37) 59P Horizontal Units (20x20) 59P Horizontal Units (20x22) 59P Horizontal Units (20x25) 59P Phone Orders: Fax Orders:

58 Disposable Filters Description 5 Series SAH Air Handler Disposable Pleated Filters, 1 MERV 4 6 month life (Minimum order qty. 12) Part Number Air Handler Units (20x16) 59P020B List Price SAH022 SAH026 SAH030 SAH036 SAH042 SAH048 SAH060 SAH066 Air Handler Units (20x20) 59P020B06 8 Air Handler Units (20x22) 59P020B Envision Air Handler Description Part Number List Price Disposable Pleated Filters, 1 MERV 4 6 month life (Minimum order qty. 12) Air Handler Units (20x24) 59P020B14 9 Synergy 3D Description Disposable Pleated Filters, 2 MERV 11 6 month life (Minimum order qty. 2) Part Number Vertical Units (28x30) 59P Vertical Units (30x32) 59P List Price SDV038 SDV049 SDV064 SDV072 Vertical Units (30x36) 59P Disposable Pleated Filters, 2 MERV 13 6 month life (Minimum order qty. 2) Vertical Units (28x30) 59P Vertical Units (30x32) 59P Vertical Units (30x36) 59P Phone Orders: Fax Orders:

59 Sales and Marketing Materials Sales Brochures Part Number Dealer Price 7 Series 700A11 BR2700AN Series 500A11 BR2500AN Series 500R11 (Indoor Split) BR2503SN Series 500RO11 (Outdoor Split) BR2504SN Series SAH Air Handler BR2518AN Series 500W11 Water to Water (NSW) BR2506WN Series 504W11 (OptiHeat) BR2508WN Series 300A11 BR2300AL 1.55 Builder Program Brochure BR1505MW 1.45 Conservation Way Brochure BR1530MW 0.85 Environmental Brochure BR1508MW 1.45 Environol Antifreeze BR1549MG Envision Water to Water (NDW) BR1007WN 1.70 Indoor Air Quality Journal BR1531MW 0.85 IntelliStart BR1629MW 1.40 IntelliZone2 BR1578MW 1.50 Planned Replacement BR1506MW 1.45 Question & Answer Booklet BR1521MW 1.45 Residential Product Line BR1510MW 1.45 Synergy3D BR1300YS 1.45 Thermostat Product Line Brochure BR1600MW 3.10 Training Material Part Number Dealer Price Aurora Training Video (DVD) DV1562MW 5.00 Flush Cart Training DVD WFS503DVD 4.55 Loop Training Video Series WFS301DVD Startup & Troubleshooting DVD DV1504MW 5.00 Synergy 3D, Air Handler, NDW Install DVD DV1500MW 5.00 Troubleshooting & Start Up Video (DVD) WFS Miscellaneous GeoTank Application Guide AG1600TG Geothermal Overview (DVD) DV1510MW 5.00 Geothermal Presentation Pocket Folder MM1502MW 3.00 Home Owner Decal (pkg. of 20) MM1508MW Home Show Packet (BR1530MW,BR1510MW,WF1536) WF Musical ID Package WF Owner's Manual OM1500MW 6.00 Residential Engineering Manual WF Troubleshooting Tablet MM1501EW WF Geothermal Business Cards (per 100) WF Spec Catalogs 7 Series 700A11 SC2700AN Series 500A11 SC2500AN Series 500R11 (Indoor Split) SC2503SN Series 500RO11 (Outdoor Split) SC2504SN Series SAH Air Handler SC2518AN Series 500W11 (Water to Water) SC2506WN Series 504W11 (OptiHeat) SC2508WN Series 300A11 SC2300AL 1.75 Environol Antifreeze SC1571EW 4.20 Envision Water to Water (NDW) SC1007WN 1.45 IntelliZone2 SC1578EW 1.35 IntelliZone2-24V SC1678EW 0.90 Synergy3D SC1300YS 3.95 Demonstration Units 7 Series vertical cabinet only NVV036TRCC Series vertical cabinet only NSV030FTRCC Series Demo Unit NSV016G901CTL 3, Series Indoor Split cabinet only NSZ030GCC Series Water to Water cabinet only NSW018CC Series vertical cabinet only LDV036TRCC Envision Water to Water cabinet only NDW100TCC Loop Model Demo LMD WaterFurnace Software Part Number Description Dealer Price SWR-GDSL *GeoLink Design Studio Energy Analysis (ver. 2.0) FREE * Demo version can be downloaded from the WaterFurnace Secure Site and registered as a full version Phone Orders: Fax Orders:

60 About Our Warranties Unit and Accessory Warranty Summary Product Standard Coverage Optional Coverage 7 Series 5 Series Envision Synergy3D Units - 10 Years, All Parts and 5 Years Labor Allowance Accessories installed with the unit- 5 Years, All Parts and Labor Allowance Units - 10 Years, All Parts and 10 Years Labor Allowance Accessories installed with the unit - 5 Years, All Parts and Labor Allowance Product Standard Coverage Optional Coverage 3 Series Additional Warranties: 5 and 7 Series Factory Installed Options: WaterFurnace recommends that the factory installed option(s) shown below be installed in the equipment during the manufacturing process. This will ensure that the option(s) is covered under the terms and conditions of the WaterFurnace unit warranty. In the event these kits are field installed by a WaterFurnace dealer within the accessory warranty, WaterFurnace will warranty the kit for the remainder of the accessory warranty. Factory installed options available as field kits: 5SAK AXB 5SRK Refrigeration and Monitoring 5SPKS-HW Performance Monitoring ( ) 5SPKL-HW Performance Monitoring ( IS60RKS Intellistart ( ) IS60RKL Intellistart ( ) WaterFurnace Replacement Parts: For the remainder of the warranty period of the unit, labor allowance if applicable. One year (from ship date) parts only if unit is out of warranty or they are installed on non-waterfurnace equipment. Accessories: One year (from ship date) part only if not installed with the unit or installed on a non-waterfurnace unit. External intermediate heat exchangers have a 1 year part only warranty from the date of shipment. GeoStorage Tank carry a 5 year parts warranty from ship date. Symphony AWL: Two years part only as specified on warranty certificate. Units - 2 Years, All Parts and Labor Allowance Refrigeration Components - 5 Years Parts and Labor Allowance Accessories installed with the unit - 2 Years, Parts and Labor Allowance Units - 5 Years, All Parts and Labor Allowance Accessories installed with the unit - 5 Years, All Parts and Labor Allowance GeoLink 55-Year No Leak Earth Loop Warranty The WaterFurnace GeoLink earth loop pipe and fittings are protected against rust, rot, electrolytic corrosion and defects in materials and workmanship for 55 years. WaterFurnace also offers an optional 55-Year No Leak Loop Warranty that covers material and labor for repairs due to materials or workmanship. WaterFurnace "Geo-Link" pipe and fittings must be used and the loop must be installed with WaterFurnace equipment by a WF Geothermal Services Contractor (GSC). 55-Year No Leak Loop Warranty applications are available directly from WF customer service. Contact WF Training for GSC certification requirements. Product Standard Coverage Optional Coverage GeoLink Loop Pipe 55 years (pipe and fittings only) 55 Year "No Leak" Warranty* 55YR-LOOP-WARR - $550 *In order to process a claim under this warranty, a quote must be submitted to the Director of Customer Support Operations and approved before any work can be started. HyperLoop not included in this warranty. The 55-Year No Leak Loop Warranty is tranferrable for a fee of $550. Contact warranty for more details or to process a tranfer. 60 Phone Orders: Fax Orders:

61 WaterFurnace Residential Warranty Claim Procedure WaterFurnace requires contractors to follow this procedure for making warranty claims with respect to products covered by Warranty Certificates issued by WaterFurnace. By submitting a warranty claim, a contractor agrees to follow, and be bound by, the WaterFurnace Warranty Claims Procedure in effect when the claim is submitted. For products that require a dealer training certification, the Express Warranty Claim Form must have the training I.D. in order to be processed. Claim Submission Claims must be submitted at warranty.waterfurance.com/claims within 30 days of failure date. Additional forms may be required depending on the part being replaced. If the claim is for labor only, the contractor must include a detailed description of what problem was found with the unit and what work was required to repair the unit. Documentation must be provided showing the failed component. See the additional instruction below for repairs of non-waterfurnace accessories. If the claim is for an accessory not manufactured by WaterFurnace (i.e., GeoTank, Alpine Pure HRV or Desert Spring Humidifiers), contractors must include the accessory model (if applicable) and serial number on the claim form. A sales order or invoice may be required to show proof of purchase. AWL Warranty Customers must purchase replacement component up front. Once the part has been replaced, customer can submit warranty claim for credit along with a copy of the invoice for the replacement part. Once the claim has been processed and an RMA issued, the customer will be responsible for returning failed component to WaterFurnace. Credit will be dependent on the analysis of the failed component. Warranty Claim Acknowledgement WaterFurnace will issue a Warranty Claim Acknowledgement within one (1) business day of receipt of a proper Express Warranty Claim Form. Any Distributor who does not receive a confirmation should CALL to check on the status of the claim. The Warranty Claim Acknowledgement will serve as an order confirmation for any claim requesting that a part(s) be shipped for the repair of a covered unit and will contain notes indicating whether parts or identity tags are to be returned. Warranty Credits and Shipping Charges WaterFurnace will issue credits for labor and refrigerant (if applicable) according to the labor allowance schedule, when the claim is processed. WaterFurnace will have the discretion to determine how the allowance will be paid and, generally, will issue credits to active accounts, rather than checks. Warranty parts will be shipped at no charge. Shipment of Replacement Parts WaterFurnace will ship warranty parts soon after it issues a Warranty Claim Acknowledgement. Unit parts lists can be found in the back section of the Installation Manual. WaterFurnace will pay the cost of ground shipment by the means that WaterFurnace chooses. The contractor may request special shipping and delivery terms, including without being limited to: Overnight delivery; and Special packaging [Expect longer delivery times]. All costs of shipping via contractor-specified terms will be at the contractor s expense and will be made F.O.B. WaterFurnace plant (or F.O.B. WaterFurnace supplier in the case of a drop shipment). Contractor will be debited for additional shipping charges at the time of shipment. If a customer submits a warranty claim for an incorrect part, the customer is responsible for all shipping charges on both parts. If incorrect part is not returned, customer will be charged. Return of Parts and Identity Tags Notes at the bottom of the Warranty Claim Acknowledgement should contain instructions as to whether parts or identity tags or both must be returned to WaterFurnace (i.e., Field Scrap after 60 Days, Return Identity Tag Only or Return Parts ). However, if no notes appear on the Warranty Claim Acknowledgement, contractors should hold all parts and identity tags for 60 days, as WaterFurnace may later request their return. Return of Identiity Tags Only In the case of flow center and desuperheater pumps, as well as some other parts, only the manufacturer s identity tag may be required to be returned via registered U.S. mail, postage pre-paid and insured. The contractor must initiate the return of the identity tags as requested on the Warranty Claim Acknowledgement. Return of Parts: Upon installation of the replacement part(s), the contractor must notify the WaterFurnace Warranty Department via at warranty@waterfurnace.com that the defective part(s) and the Warranty Claim Acknowledgement are packaged together and ready for pick up at a location to be designated by the contractor at the time of the call. Note: Any identity tags that may also need to be returned may be packaged with the return part(s) and the Warranty Claim Acknowledgement. The contractor must notify the Warranty Department if including tags along with other returns. The contractor has 30 days from the later of the issuance of the Warranty Claim Acknowledgment or the date when WaterFurnace first requests the return of a part to change the parts, package them and properly requests a call tag for pick-up. Upon the contractor s request, WaterFurnace will initiate a call tag to pick up the item at the contractor s designated location by the shipping means of WaterFurnace s choice. Return shipping costs will be incurred by WaterFurnace. The call tag must be used within 10 days of issuance. If the contractor fails to use the call tag within the time allowed, the contractor must pay for return shipment of the parts. Rev 1.18 Phone Orders: Fax Orders:

62 WaterFurnace Residential Warranty Claim Procedures cont. The contractor must take reasonable precautions to ensure that parts are returned in good condition (except for the cause of failure), including but not limited to: Brazing shut refrigerant fittings on returned compressors; and Cutting out, not torching, all refrigerant components. Inspection and Testing of Returned Parts: WaterFurnace will inspect and test the returned part(s) to confirm that failure was covered by the applicable warranty. If no warranted fault is found or the returned part is (parts are) so damaged that no testing is possible, WaterFurnace, at its discretion, may return the part to the contractor at the contractor s expense, and debit the contractor s account in the amount of the claim (parts and labor). Failure to Return Parts or Identity Tags: If required parts and identity tags are not returned within three weeks of the later of the issuance of the Warranty Claim Acknowledgment or a later request for return of parts or identity tags, WaterFurnace will fax or one (1) reminder to the contractor. If the call tag is not requested or the required identity tag(s) are not returned within one (1) week following the issuance of the reminder, the contractor s account will be debited in the amount of the claim (parts and labor). Only one (1) call tag will be issued per part and it must be used within 10 days of its issue date. If the call tag is not used within 10 days of issuance, the contractor s account will be debited in the amount of the claim (parts and labor). Unused Warranty Parts If the warranty replacement part is furnished but not used, it is the contractor s responsibility to contact a WaterFurnace Warranty Representative to advise him/her that the part will be sent back to WaterFurnace. The Warranty Representative will provide the contractor with the appropriate paperwork that must be returned with the part. All parts must be received in a new and unused condition, and all shipping charges will be for the account of the contractor. Failure to return the unused part in new and unused condition will result in a debit to the contractor s account for the value of the part. WaterFurnace will also debit the contractor s account for all labor, refrigerant, shipping and other credits previously given with respect to or for use in connection with the unused part. Use of Non-WaterFurnace Parts Customers are generally encouraged to use WaterFurnace replacement parts. However, if a WaterFurnace part cannot be obtained in a timely manner or in other unusual circumstances, a Customer may choose to use a repair part purchased locally in lieu of using a WaterFurnace furnished part. The following terms will apply in those cases: The non-waterfurnace part must meet WaterFurance specifications. Return of parts or identity tags or both may be required as otherwise specified in this procedure. The Customer must submit with the Express Warranty Claim Form a copy of the invoice for the purchased part. WaterFurnace generally will not credit the Customer with an amount greater than the cost of a WaterFurnace replacement part and will have discretion to determine the amount of any credit and the manner in which it will be credited. WaterFurnace will not warrant the non-waterfurnace part or provide any present or future labor allowance with respect to the non- WaterFurnace part; warranty will be the responsibility of the installing contractor. All Debits Final WaterFurnace s determination that a contractor has failed to properly return parts and/or identity tags, parts returned with no error found, or as to the allowable amount of any claim (parts and labor) shall be final and binding on all parties. Once the contractor s account is debited, no credits will be made. Amendments or Waivers THE COVERAGES OF A WARRANTY AND THE VALIDITY OF AND DAMAGES ALLOWED UNDER A WARRANTY CLAIM WILL BE DETERMINED BY THE UNDERLYING RESIDENTIAL WARRANTY CERTIFICATE ISSUED WITH THE PRODUCT (AND ACCESSORIES), THE SERIAL NUMBER FOR WHICH IS IDENTIFIED ON THE CERTIFICATE. FOR CLAIMS WITH RESPECT TO A PART PURCHASED AFTER THE EXPIRATION OR OTHERWISE OUTSIDE THE ORIGINAL WARRANTY CERTIFICATE, COVERAGES, DAMAGES AND VALIDITY WILL BE DETERMINED BY THE CONTRACT FOR SALE OF THE PART (E.G., REPLACEMENT PARTS PURCHASED OUTSIDE THE ORIGINAL CERTIFICATE ARE WARRANTED FOR PARTS ONLY WARRANTY FOR ONE YEAR FROM THE INITIAL INSTALLATION). RIGHTS OF THE PARTIES WITH RESPECT TO ALL CLAIMS ARISING FROM OR WITH RESPECT TO THE APPLICATION OF THIS PROCEDURE SHALL BE GOVERNED BY THE TERMS OF THE UNDERLYING WARRANTY CERTIFICATE OR SALES CONTRACT UNDER WHICH THE WARRANTY CLAIM WAS MADE. This is the exclusive warranty claims procedure for the applicable warranties. WaterFurnace may amend this procedure at any time. Amendments to or waivers of the warranty claims procedure will be effective only if confirmed in writing by WaterFurnace. A change of terms in any one case will not indicate or require a change in terms in any other case. As used in this procedure, WaterFurnace includes separately or collectively, its affiliates and the representatives, successors and assigns of any or all of them. This procedure inures for the benefit of WaterFurnace. Rev Phone Orders: Fax Orders:

63 Warranty Buy Up Policy Buy ups on warranty may be allowed up to 12 months from the original ship date, as long as no warranty claims have been processed within one year from the ship date. If the unit has any warranty claims, the terms of the warranty cannot be changed. The warranty buy up is subject to cancellation if a claim is submited within 30 days of the buy up. No exceptions will be made beyond 12 months. The following form must be filled out when buying up the warranty. Fax: (800) Phone: (800) warranty@waterfurnace.com Warranty Buy Up Form All Warranty Buy Ups must be processed within 1 year from ship date! Subject to cancellation if claim submitted within 30 days of buy up! No warranty claims may be submitted on a unit applying for a warranty buy up! All warranty buy ups will be processed with the standard multiplier. Unit Serial #: Unit Model #: Original Warranty: Desired Warranty: PO # / Job Name: Customer Name: Customer Acct#: Phone #: Owner s Name: Address: Start-up Date: Customer Signature: Date: Title: WaterFurnace Signature: Date: Title: WF285-WFI 10/17

64 Date Page Description 5/11/18 3 Updated Freight Policy 5/11/ Added note on lead time for Outdoor Package unit 7/11/18 47 Added GeoBooster 7/16/18 ALL Updated all prices WaterFurnace International 9000 Conservation Way Fort Wayne, IN Phone: 888/ Fax: 800/ WaterFurnace works to continually improve its products. As a result, the design, specifications, and pricing of each product at the time of order may be changed without notice and not be as described herein. Please contact WaterFurnace customer service department at 888/ for specific information on the current design, specifications or pricing. 7 Series, 5 Series, 3 Series, Envision, Synergy3D, IntelliZone, GeoTank, Environol, and GeoLink are registered trademarks of WaterFurnace International Inc. As an ENERGY STAR Partner WaterFurnace has determined that some products meet the ENERGY STAR guidelines for energy efficiency WaterFurnace International, Inc. PB1548MW 7/16/2018

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS Water Source/Geothermal Heat Pumps GEOTHERMAL TECHNOLOGY THE BENEFITS ENERGY EFFICIENT: WaterFurnace geothermal systems are simply the most efficient

More information

AFFORDABLE RENEWABLE CLEAN

AFFORDABLE RENEWABLE CLEAN AFFORDABLE RENEWABLE CLEAN P R O D U C T L I N E HE ATING CO O LING HOT WATE R w w w. g e o s t a r - g e o. c o m A F F O R DA B L E R E N E WA B L E CLEAN GEOTHERMAL HEAT PUMPS WHAT IS GEOTHERMAL? Geothermal

More information

ALL THE COMFORTS OF HOME WATERFURNACE RESIDENTIAL PRODUCT LINE

ALL THE COMFORTS OF HOME WATERFURNACE RESIDENTIAL PRODUCT LINE ALL THE COMFORTS OF HOME WATERFURNACE RESIDENTIAL PRODUCT LINE SMARTER FROM THE GROUND UP FORCED AIR UNITS Heat & cool your home the smart way with a WaterFurnace geothermal comfort system using the clean,

More information

Versatec Ultra Series Installation Manual

Versatec Ultra Series Installation Manual Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant 0.75-6 Tons Installation Information Water Piping Connections Hot Water Connections Electrical Startup Procedures Versatec Ultra Series Installation

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

COMMERCIAL PRODUCT LINE

COMMERCIAL PRODUCT LINE COMMERCIAL PRODUCT LINE W A T E R S O U R C E G E O T H E R M A L H E A T P U M P S AFFORDABLE RENEWABLE CLEAN A FAMILY OF OVERACHIEVERS. TYPICAL APPLICATIONS GeoStar products can be designed to fit into

More information

SPECIFICATION CATALOG. Commercial 0.75 to 6 Tons. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 0.75 to 6 Tons. Geothermal/Water Source Heat Pump SPECIFICATION CATALOG Commercial 0.75 to 6 Tons Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature........................................................... 4 AHRI Data...................................................................5-6

More information

Residential Product Price Catalog Effective: 01 April 2013 Rev.: 06 June tetcogeothermal

Residential Product Price Catalog Effective: 01 April 2013 Rev.: 06 June tetcogeothermal Residential Product Price Catalog Effective: 01 April 2013 Rev.: 06 June 2013 tetcogeothermal www.tetco-geo.com Effective: 01 April 2013 Table of Contents: Welcome... 2 A Helpful Guide to Selecting Units

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

GEOTHERMAL: THE SMARTER CHOICE

GEOTHERMAL: THE SMARTER CHOICE GEOTHERMAL: THE SMARTER CHOICE CONSUMER LITERATURE Heating and Cooling Products WHY TEMPSTAR HEATING AND COOLING PRODUCTS? Throughout the historic legacy of Tempstar Heating and Cooling Products, the company

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

HEATING COOLING HOT WATER PRODUCT LINE

HEATING COOLING HOT WATER PRODUCT LINE G e o t h e r m a l H e a t P u m p s HEATING COOLING HOT WATER AFFORDABLE RENEWABLE CLEAN PRODUCT LINE WHAT IS GEOTHERMAL? Geothermal units are similar to ordinary heat pumps but use the solar energy

More information

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com boschheatingandcooling.com 1 Greensource iseries Water Source Heat Pumps SV Model Made in Florida boschheatingandcooling.com 1 Replacement Water Source Heat Pump About the Bosch Group The Bosch Group has

More information

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.

More information

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction From 230 tons to Water-Source eat Pump Products Premium Performance Environmentally Friendly Superior Construction Water-Source eat Pump Products Small Packaged Water-Source eat Pumps (1/2 to 30 tons)

More information

Manufacturer Update 2014 IGSHPA

Manufacturer Update 2014 IGSHPA Bosch FHP Commercial Manufacturer Update 2014 IGSHPA Ø LV Single Stage Split System Heat Pump Ø LM Two-Stage High Efficiency Packaged Heat Pump Ø New Extended Warranty Options Chilton Stewart National

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump

More information

Synergy3D Installation Manual

Synergy3D Installation Manual Geothermal Heat Pumps with Water Heating for Radiant Floor Applications 3 thru 6 Ton Installation Information Water Piping Connections Synergy3D Installation Manual Electrical Connections Startup Procedures

More information

Water-Source Heat Pumps

Water-Source Heat Pumps ater-source eat Pumps SERIES Features: ½ to 20 ton orizontal Configuration Left or Right Return Left, Right, or End Discharge igh Efficiency PSC or ECM Supply Fan Motor Reliable Scroll or Rotary Compressors

More information

BOSCH RESIDENTIAL GEOTHERMAL HEAT PUMPS

BOSCH RESIDENTIAL GEOTHERMAL HEAT PUMPS www.bosch-climate.com INDEX AIR HANDLING UNITS UNITARY DX SERIES... 5-6 HYDRONIC SERIES... 5-6 HEAT PUMPS GEO 1000 WA BP SERIES... 5-4 GEO 3000 WA CE SERIES... 5-5 CP SERIES... 5-4 GEO 6000 WA / WW TA

More information

Fan Coils & Air Handlers Product Catalog

Fan Coils & Air Handlers Product Catalog Fan Coils & Air Handlers Product Catalog 120V/240V motors PSC and ECM high efficiency constant torque motors Heavy-gauge, galvanized steel construction High efficiency rifled copper tubes/enhanced aluminum

More information

FORCED AIR + HYDRONIC

FORCED AIR + HYDRONIC FORCED AIR + HYDRONIC The WaterFurnace Synergy3D series provides forced air heating & cooling and hydronic heat for radiant floors in one convenient package. It was engineered with leading edge components,

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

GEOTHERMAL HEAT PUMPS

GEOTHERMAL HEAT PUMPS RESIDENTIAL PRODUCT LINE A FFI N I T Y A N D L X S E R I E S GEOTHERMAL HEAT PUMPS The ground absorbs 46% of the sun s radiation. 10 Heating Mode 96 When temperatures drop, a geothermal heat pump taps

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Geothermal. Comfort Systems

Geothermal. Comfort Systems Geothermal Comfort Systems As an ENERGY STAR partner, Carrier Corporation has determined that the Geothermal Comfort System meets ENERGY STAR guidelines for energy efficiency. The Carrier Geothermal Advantage

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

That s why we call it Smarter from the Ground Up.

That s why we call it Smarter from the Ground Up. The WaterFurnace Synergy3D series provides forced air heating & cooling and hydronic heat for radiant floors in one convenient package. It was engineered with leading edge components and takes efficiency

More information

Greensource Residential Geothermal Heat Pumps. Think Green Think Renewable Think. iseries: SV Model Split System. boschheatingandcooling.

Greensource Residential Geothermal Heat Pumps. Think Green Think Renewable Think. iseries: SV Model Split System. boschheatingandcooling. Greensource Residential Geothermal Heat Pumps iseries: SV Model Split System boschheatingandcooling.com 1 boschheatingandcooling.com Think Green Think Renewable Think 1 Residential Geothermal Heat Pumps

More information

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018 Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................

More information

DXair Pool Dehumidifiers

DXair Pool Dehumidifiers DXair Pool Dehumidifiers LV Series / to 6 Ton G-60 Galvanized The option-rich DXair LV Series pool dehumidifier has one of the smallest cabinets in the industry, making it a great choice for replacement

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA Manufacturer of HVAC Equipment Since 1916 400,000 sq. ft. on 16 acres Colton, California USA Visual factory Vertically integrated manufacturing BELT-DRIVEN AIR HANDLERS 800 12,000 CFM Horizontal Vertical

More information

Geothermal Comfort System. 7 Series 700A11

Geothermal Comfort System. 7 Series 700A11 Geothermal Comfort System 7 Series 700A11 The 7 Series With Variable Capacity Technology The WaterFurnace 7 Series is quite possibly the most advanced heating and cooling system on the planet. It provides

More information

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15 AI HANDLE -0A efrigerant - Tons Submittal Data English Language/IP Units SD00HN 0/ ontractor: ENVISIN AI HANDLE - Tons Model Nomenclature - - - 0 NAH 0 * 00 0 Model NAH Envision Series Air Handler Unit

More information

FOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30,

FOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30, 13 12 00 FOUNTAINS A. Due to water conservation efforts and the high maintenance requirements of fountains, new interior and / or exterior fountains are not allowed. B. If a variance is granted for a fountain,

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should

More information

Mammoth Water Source Heat Pumps

Mammoth Water Source Heat Pumps Mammoth Water Source Heat Pumps Products Mammoth WSHP Group November 2014 Copyright 2014 CES Group. All rights reserved. Water Source Heat Pump Products Single Circuit U Vintage ¾ to 5 tons Horizontal

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR AQUECOIL HYDRONIC HEATING UNITS GENERAL INFORMATION The AQUECOIL Hydronic Heating Unit is offered in many different capacities and physical configurations in order to match

More information

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG: Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

LV Split Systems Water Source Heat Pump

LV Split Systems Water Source Heat Pump LV Split Systems Water Source Heat Pump 1½ to ton boschheatingandcooling.com and coolin g.c om 1 The option-rich LV Split Systems offer lower operating costs, space-saving flexibility and quiet comfort,

More information

SPECIFICATION CATALOG. Commercial 7 to 25 Tons. Geothermal/Water Source Heat Pump

SPECIFICATION CATALOG. Commercial 7 to 25 Tons. Geothermal/Water Source Heat Pump SPECIFICATION CATALO Commercial 7 to 25 Tons eothermal/water Source Heat Pump Table of Contents Model Nomenclature........................................................... 4 AHRI Data...................................................................5-6

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

Greensource Residential Water Source Heat Pumps

Greensource Residential Water Source Heat Pumps TM boschheatingandcooling.com 1 Greensource Residential Water Source Heat Pumps Si Series: CE Model The Si Series CE Model contains a two stage compressor, variable speed ECM motor and comes with a variety

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Catalog SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps

Catalog SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps GTH - Horizontal Ceiling GTV - Vertical Floor Unit Sizes 026 072 R-410A Refrigerant Catalog 1114-8 Contents Model Nomenclature... 4

More information

Innovative Design, Performance, & Serviceability

Innovative Design, Performance, & Serviceability Innovative Design, Performance, & Serviceability AAON Experience For over 15 years AAON has manufactured Water-Source Heat Pump (WSHP) Rooftop Units, Vertical Self-Contained Units, and Modular Air Handling

More information

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering

More information

50 Series AQUAZONE Water Source Heat Pumps

50 Series AQUAZONE Water Source Heat Pumps 50 Series AQUAZONE Water Source Heat Pumps.5 TO 25 TONS EFFICIENT, ECONOMICAL, ENVIRONMENTALLY SOUND HEATING AND COOLING SYSTEMS AQUAZONE Versatile Systems For Affordable Comfort Water source heat pumps

More information

Envision Air Handler Specification Catalog

Envision Air Handler Specification Catalog Air Handler Design Features Factory ptions Accessories Dimensional Data Physical Data Performance Data Engineering uide Specifications Envision Air Handler Specification atalog S00HN 0/ ENVISIN AI HANDLE

More information

Vertical V*B Series Fan Coil Technical Catalog

Vertical V*B Series Fan Coil Technical Catalog Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with

More information

Geothermal Comfort Systems

Geothermal Comfort Systems Geothermal Comfort Systems The Bryant Geothermal Advantage Throughout Bryant's historic 100-year legacy, the company has provided millions of homeowners with the finest comfort systems available. Using

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

PCAH SERIES AIR HANDLER

PCAH SERIES AIR HANDLER PCAH SERIES AIR HANDLER PCAH2/PCAH3/PCAH4 OPERATING MANUAL 1 2 3 4 5 6 7 8 9 10 TABLE OF CONTENTS GETTING STARTED... 3 ELECTRICAL CONNECTIONS... 3 2.1 POWER CONNECTIONS... 3 2.1.1 PCAH2/PCAH3... 3 2.1.2

More information

GEOTHERMAL COMFORT SYSTEMS

GEOTHERMAL COMFORT SYSTEMS GEOTHERMAL COMFORT SYSTEMS PACKAGED, SPLIT, and WATER-TO-WATER UNITS Complete Comfort, Energy Savings, and Exceptional Service Provided by Your Bryant Dealer Models GC, GP, GB, GZ, and GW The Bryant Geothermal

More information

CONDENSERS AND CONDENSING UNITS

CONDENSERS AND CONDENSING UNITS CONDENSERS AND CONDENSING UNITS CF Series Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

Multi-position Air Handler

Multi-position Air Handler Multi-position Air Handler * Note: No internal modifications required for any position. 1 Badge rotation will keep brand in correct position Airflow Refrigerant Connections 1 Refrigerant Connections 1

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List Technical Data Manual Model Nos. and pricing: see Price List Viessmann AirflowPLUS AH2A series Hydronic forced air handler Viessmann AirflowPLUS Product may not be exactly as shown Viessmann AirflowPLUS

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) with refrigerant Product Description Performance and Electrical Data Dimensional Data Guide

More information

Synergy3D Installation Manual

Synergy3D Installation Manual Geothermal Heat Pump with Water Heating for adiant Floor Applications -40A efrigerant 3, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Synergy3D Installation Manual Hot Water

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Water Source / Geothermal Heat Pumps & Air Conditioners

Water Source / Geothermal Heat Pumps & Air Conditioners WATER SOURCE / GEOTHERMAL HEAT PUMPS Water Source / Geothermal Heat Pumps & Air Conditioners WHISPERLINE VERTICAL STACK u Classic Heat Pump / Air Conditioner u Single Riser Heat Pump / Air Conditioner

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

Geothermal Comfort Systems

Geothermal Comfort Systems Geothermal Comfort Systems Qualifying Models Only GC, GP, GB, GZ, GW The Carrier Geothermal Advantage Throughout Carrier s historic 100-year legacy, the company has provided millions of homeowners with

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models UP TO.7 EER Lennox units deliver comfort and control that you can depend on The latest offerings from Lennox represent a new design in air conditioners

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993 Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call

More information

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual

More information