New HEE control. nroom thermostat for THREE-PHASE or SINGLE-PHASE installation

Size: px
Start display at page:

Download "New HEE control. nroom thermostat for THREE-PHASE or SINGLE-PHASE installation"

Transcription

1 New H400 model New HEE control The most competitively priced technical solution for heating large spaces Ensures buildings warm up ultra fast Excellent diffusion via patented JET+ double deflection technology New High Energy Efficiency motor version ErP READY Heating Cooling and heating Use In wallmounted or ceilingmounted versions, the HELIOTHERME is the simple, affordable heating/cooling solution for all your applications: for your premises in the service sector (sales outlets, halls, multipurpose rooms etc.) or in industry (workshop, garage, storage unit, logistics platform, etc.). The HELIOTHERME range meets APSAD and NFPA recommendations on air velocities along the edges of units. All are less than 5 m/s at 0.5 m from the diffuser and thus do not interfere with sprinkler systems. The air heater may be combined with destratifiers (TPL) to promote mixing of the air within the building. (Antistratification solution) HELIOTHERME ATEX version: voluntary type examination certificate LCIE ATEX 05 X gas and/or dust environment. HELIOTHERME version 46S: specially designed for "logistics platforms". Only available as hot water with 400 V/ PH/50 Hz power supply. Control A range of "Plug & Play" proportional airsource/watersource controllers with heat exchanger (or electric heater) are used to control the air flow of the fan motor assembly and the heating capacity required for the room, according to the occupancy periods (builtin timer). LP water + PH FMA application: PH Eco+ BOX can control up to x PH H4000. LP water + PH FMA application: PH Eco+ BOX can control up to 9 x PH H4000. Elec. + PH FMA application: ELEC. Eco+ BOX can control up to x ELEC. H4000. LP water + PH HEE FMA application: PH HEE BOX can control x PH HEE H x PH HEE TPL or 6 x PH HEE H4000 or 6 x PH HEE TPL Options and accessories n Wall bracket, ceiling bracket, IPN additional kit n Filter box n 2channel mixing box with builtin filter n Specific diffuser (on door, highlevel etc.) n Antifreeze damper nroom thermostat for THREEPHASE or SINGLEPHASE installation n / switch for PH fan motor assembly n 5 speed autotransformer for SinglePhase AC FMAs n Proximity switch, circuit breaker

2 TPL determination and selection example S = Supply (released at the top of the building) TR = Temperature under roof TW = Temperature setpoint in the work area S Calculated flow rate for destratifiers = 0. x (TRTW) Selection example: Supply under building roof = S = 45,000 kcal (52,200 Watts) Temperature under roof = TR = 0 C Temperature setpoint in the work area = TW = 6 C Calculated flow rate for destratifiers = 0. x (06) = 074 m /h So: 2 x TPL 4500 at or x TPL 460 at. Range Heating/cooling medium LP water HP superheated water Oil HP steam Electrical Standard drive Reinforced variant THREEPHASE 2 speeds SINGLEPHASE variable speed IP44/54 depending on the model CORROBLOC version IP 55/65 700hour salt spray test Coil (tubing/row) Copper/Alu Steel/Alu Cupronickel/Alu Stainless steel/alu Reinforced versions Casing Reinforced versions ATEX versions 6L stainless steel tubes/heresite coating Precoated offwhite (RAL 705) galvanised steel Condensate pan + builtin nautical coupling for cooling 04L Stainless steel/doublesided coating LCIE ATEX 05 X Zone or 2 IIB or IIC T4 or T6 Standard/HEE Reinforced version (high resistance to corrosion) ATEX version Heating/cooling medium HEE drive Coil (tubing/row) Casing Reinforced versions LP water with HEE FMA phase variable speed with 00 V signal IP 54 Copper/Alu Precoated offwhite (RAL 705) galvanised steel Condensate pan + builtin nautical coupling for cooling 04L Stainless steel/doublesided coating Operating principle HELIOTHERME units are installed at the end of a centralised heating or cooling system (boilers, airsource or watersource heat pump, reversible unit). AQUACIAT 2 LD ILD 2

3 Description Axial air heaters Highefficiency fan motor assembly Silent FMA featuring an aluminium epoxy polyestercoated airfoil propeller to ensure the best compromise between air flow efficiency and acoustic comfort. The ROTOREX design (windings inserted in the fan hub) keeps the motor cool to ensure that it operates at optimum efficiency. Three versions are available : n THREEPHASE 2 speed (20/400V Ph 50Hz) (accessory / switch) n SINGLE PHASE variable speed (20V Ph 50Hz) (accessory 5speed autotransformer) n CORROBLOC version guaranteed to withstand corrosive environments. HEE FMA Fan motor assembly equipped with a powerful HEE EC (electronically commutated) motor. These EC motors (singlephase 20V Ph 50/60V drive) will be progressively controlled by the 00 V signal, to ensure acoustic comfort and air flow efficiency and to optimise consumption of electricity. A shunt can be used to operate the air heater at maximum speed. CORROBLOC FMA IP65/700hour salt spray test Casing Elegant galvanised steel casing, precoated with RAL 705 (light grey) paint (stainless steel version available on request). Condensate drain pan builtin for cooling applications, featuring an antibacterial design (perforated bottom) and quickrelease fitting (diameter '/4). Intake section optimised for improved air flow performance and acoustic comfort level. Advantages: Its classic design means that it can easily blend into the architecture of the installation site. No need to add an unsightly condensate drain pan. Condensate pipes quick and extremely simple to connect, without any need for a clamp, ('/4 diam. quickrelease fitting). Diffuser Double deflection diffuser made from rigid aluminium sections, based on the BERNOULLI fluid flow principle and on NACA002 airfoils, creating a high induction rate on the primary air, in order to increase the air throws, limit the stratification phenomenon and thereby reduce energy consumption. n Basic version (only for the H 460 S): Singledeflection diffuser with directional louvre Lightgrey galvanised steel louvre n JET+ version (fitted as standard): Double deflection diffuser JET+ aluminium louvre with NACA002 airfoil design Each louvre can be adjusted independently Advantages: Air flows adjustable in 4 directions for optimum coverage of the area to be handled, while limiting draughts. Laminar air flow for better acoustic comfort (zero turbulence at the diffuser outlet). Increased air speed, thanks to the resulting aerodynamics (depression along lower surface of blade) due to the curve of the airfoil, thereby increasing the air throws and the induction rate. Limited stratification phenomenon. Reduced building warmup times: Recorded energy savings of 5 to 20%. Heat exchanger HIGH EFFICIENCY heat exchanger coil with tapered intake baffles, to help pressurise the finned block, available in four versions: n LP hot or cold water version Available with, 2 or rows: Copper tube Ø 9.52 mm Embossed aluminium fins Thickness 0/00 mm Fin spacing 2. mm Advantage: Excellent thermal yield (dry transfer coefficient > 50 W/m².k) n HP superheated water oil version Available with row: Heavygauge steel tubing (Ø 6 mm) (Stainless steel available on request) Embossed aluminium fins Thickness 28.5/00 mm Fin spacing 2.5 mm Compatible for use with thermal oils Advantage: robust finned aluminium coil block suitable for use in industrial environments (dirty air) and may be cleaned using a highpressure water jet. n HP steam version Available with row: Heavygauge cupronickel tubing (Ø 6 mm) Embossed aluminium fins Thickness 28.5/00 mm Fin spacing 2.5 mm Advantage: excellent corrosion resistance thanks to chemicals pumped through steam network piping. n Electrical version Four capacities available: Stainless steel singletube heating element Embossed aluminium fins Thickness 0/00 mm Fin spacing 2.5 mm Double overheating thermostat with automatic and manual reset for compliance with fire safety standards (CH7) Advantage: Heating elements inserted directly into the finned block ensure excellent heat transfer.

4 Axial air heaters Comparative study of AC and HEE FMAs Study comparing two air heaters in heating mode, () an Air heater fitted with an AC FMA (without JET+ diffuser) and (2) a HELIOTHERME fitted with an HEE FMA (with JET+ diffuser). Space volume: 240 m² under 5 metres of ceiling, i.e m Type of insulation: light (such as in a workshop or small distribution centre) Temperature to be maintained in occupied space: 7 C Average outdoor temperature used: 5 C Heating period: November to March Heating time range: 7.00 to 9.00 Necessary heating capacity: 80W/m² i.e kw (at 5 C) AIR HEATER WITH AC FMA HELIOTHERME WITH HEE FMA COST OF INSTALLATION Mixing rate: 6 (or 7,200 m/h to be provided) Mixing rate: 4 (or 24,800 m/h to be provided) (Lower rate achieved by adjusting the air flow via the 00 V signal of the FMA connected to the HEE BOX) Unit selected: 6 x H450 PH AC Total flow rate supplied = 7,200 m/h Total heating capacity delivered = 94 kwh Unit selected: 6 x H445 PH HEE Total flow rate supplied = 24,800 m/h Total heating capacity delivered = 46 kwh Total price of air heaters Total price of air heaters ECO+ PH BOX control + installation costs Plug & Play HEE BOX control OPERATING COST Basis for analysis: Energy price assessed according to the Pegase database for energy statistics Total number of heating days = 00 (20 per month from November to March) Running time needed each day to maintain 7 C in the comfort zone 960 minutes a day Running time needed each day to maintain 7 C in the comfort zone 760 minutes a day à or 600 hours a year à or 268 hours a year: 42 hours at maximum power and 845 hours at half /2 flow power (or a saving of 2 hours of operation) 58,720 kw of boiler power used Annual heating expenses Annual electricity expenses for AC FMA 605 Total expenses 25,786 kw of boiler power used Annual heating expenses (savings of 25%) Annual electricity expenses for HEE FMA (savings of 60%) Total expenses (savings of 0%) 2,09 4 9,068

5 HELIOTHERME performance 20V/Ph/50Hz motor AC and HEE HEATING 20V/Ph/50Hz motor AC and HEE Model No. rows Heating capacity Air supply speed Flow rate Air speed Range (metres) Sound pressure (kw) SINGLE PHASE m /h m/s Wallmounted pump Suspended accelerator HPS db(a) H m/s 5 5,87 40, m/s m/s ,07 6,92 48 H m/s 5 2, m/s m/s m/s 5 2, m/s 24 7,5 44,55 52, m/s 26 8,5 48,85 56,7 54 H m/s 9 4, m/s m/s 20 5, m/s m/s m/s 27 8,5 56 H m/s m/s 2 4, m/s m/s 8, m/s ,79 86, m/s , H m/s m/s m/s 2 5, m/s 24 6, m/s m/s 28 0,5 55,40 49,80 54 H m/s m/s 24 8, m/s 2 6, m/s Model No. rows Air supply speed HEATING COOLING 20V/Ph/50Hz Motor AC and HEE Air flow rate Air speed Range (metres) Sound pressure m /h m/s Wallmounted db(a) H450 AC m/s 2 0 H4400 AC m/s H4450 AC m/s H4500 AC m/s 2 54 H460 AC H400 HEE m/s 2 4 H450 HEE m/s 2 0 H4400 HEE m/s H4450 HEE m/s H4500 HEE m/s 2 54 H460 HEE m/s 2 5 ELECTRIC HEATING 20V/Ph/50Hz Motor AC only Model Air supply Flow rate Air speed Range (metres) Electrical power (kw) Sound pressure speed m /h m/s Wallmounted Total No. of stages Power per stage db(a) m/s kw kw m/s kw m/s kw kw m/s 24.5 kw m/s kw kw m/s 26 8 kw m/s kw 4.4 kw x m/s Specifications determined using the following information: n Superheated water (HP SW): Temperature C/RT=5 C RH 50% nsteam (HPS): Temperature 75 C 8 bar/rt=5 C RH 50% n Air stream: * with JET+ diffuser for a residual speed of 0. m/s * defined with êt OT/RT of 5 C (heating) and 7 C (cooling) * with LP water or electric heating n Air speed: JET+ diffuser outlet n Sound pressure: measured 5 metres from unit, directivity 2, attenuation of 22 db é : speed obtained when wired directly to singlephase motor. é (version with AC motor): supply air speed obtained with autotransformer set to "". Other operation points (5 in total) can be supplied on request by your agent using our technical selection software. 5

6 HELIOTHERME performance Superheated Water and Steam 400V/Ph/50Hz motor Model H450 H4400 H4450 H4500 H460 Model H450 H4400 H4500 No. rows Air supply speed HEATING 400V/Ph/50Hz motor Air supply speed Flow rate Air speed Range (metres) Heating capacity Sound (kw) pressure PH m /h m/s Wallmounted Suspended accelerator pump HPS db(a) ê m/s ,87 40, m/s 7,5 2,07 6,92 44 ê m/s m/s 5 2,5 45 ê m/s 8 4, m/s ê m/s ,85 56, m/s ,55 52,75 5 ê m/s m/s ê m/s 22 6, m/s 7,5 52 ê m/s m/s 2 5,5 49 ê m/s m/s 2 4,5 50 ê m/s 24 7, m/s ê m/s , m/s ,79 86,82 50 ê m/s m/s ê m/s 26 8, m/s 2 5,5 52 ê m/s 29,5 55,40 49, m/s 24 8, ê m/s 26 0, m/s 22 7,5 49 ê m/s m/s ELECTRIC HEATING 400V/Ph/50Hz motor Flow rate Air speed Range (metres) Electrical power (kw) Sound pressure m/h m/s Wallmounted Total No. of stages Power per stage db(a) ê m/s kw kw m/s kw 44 ê m/s kw kw m/s 2.5 kw 5 ê m/s kw kw m/s 26 8 kw 50 ê m/s kw 4.4 kw x m/s Specifications determined using the following information: n Superheated water (HP SW): Temperature C/RT=5 C RH 50% nsteam (HPS): Temperature 75 C 8 bar/rt=5 C RH 50% n Air stream: * with JET+ diffuser for a residual speed of 0. m/s * defined with êt OT/RT of 5 C * with LP water or electric heating n Air speed: JET+ diffuser outlet n Sound pressure: measured 5 metres from unit, directivity 2, attenuation of 22 db TPL air flow and acoustic performance TPL /400VPh50Hz Motor (phase 400V coupling) r r r r 20VPh50Hz Motor AC and HEE Flow rate m /h Air stream m Sound pressure db(a) Specifications determined using the following information: Air stream:* with JET+ diffuser for a residual speed of 0. m/s Sound pressure: * measured 8 metres from unit, directivity 2, attenuation of 26 db 6

7 Inlet/Outlet water Axial air heaters HELIOTHERME performance Hot water 20V/Ph/50Hz motor AC and HEE H402* H45 H452 H45 Air flow rate (m³/h) Air flow rate (m³/h) Air flow rate (m³/h) Air flow rate (m³/h) Air flow rate (m³/h) Air flow rate (m³/h) Air flow rate (m³/h) Hc 7, 5,8 4,8,9,9 0, 9,62,5 0,6 9,9 9,28 2, 9,6 8,4 7, 9,6 8, 6,9 5,8 25,9 2,9 22, 20,8 2,7 2,8 20,4 9 PD 42,7 6,8 2,7 28,9 7,9 6,95 6, 5,4 7,4 6,42 5,7 5,07 7,94 6,82 6,04 5, 6,82 5,86 5,8 4,58 7,65 6,5 5,77 5,0 6,4 5,5 4,87 4,24 Hc 0,7 9,4 8,46 7,52 7,2 6,9 5,49 4,77 6,87 5,97 5,29 4,6 2,8, 9,8 8,5,7 0,2 9 7,84 5,5,4,9 0,4 4, 2, 0,8 9,45 PD 8,4 4,6 2 9,65,7 2,6 2,2,65,7 2,46,99,55,24 2,48 2,54 2,77 2,4,7, 2,29,82,4 2,5,9,54, Hc 7,08 6,7 5,49 4,8 6,8 5,95 5,29 4,65 2,6 9,74 8,5,6 0, 8,96 7,85 5,2,2,7 0,,8 2 0,7 9,5 PD 40,4,7 25,7 20, 7,9 29,5 24 9, 4,4,9 25,6 20 5,4 27, 22 7,2 40 0, 24,4 8,9,5 25,6 20,4 5,8 Hc 7,52 6,62 5,94 5,27 7,26 6,8 5,74 5,09,4,8 0,6 9,6 2,4 0,8 9,7 8,62 6, 4, 2,8, 4,8,7 0, PD 9, 5, 2,6 0, 8, 4,4,9 9,52 9, 5,2 2,4 9,87 6,6 0,6 8,48 8,5 4,4,7 9,29 5,5 2, 9,8 7,8 Inlet/Outlet water H440 H4402 H Hc 7,2 5,9 4,9,9 6,8 5,5 4,5,5,9 29,4 27,5 25,7 0,9 28,5 26,7 24,9 40, 6,9 4,6 2, 8,6 5,5,2 PD 7,24 6,25 5,55 4,9 6,9 5,96 5, 4,68,9,9 0,5 9,24,2 9,9 8,7,,4 0, 8,9 2, 0,6 9,7 8,26 Hc 0,2 8,8 7,78 6,72 9,9 8,58 7,58 6,55 9, 6,9 5, 8,7 6,4 4,5 2,7 24,2 20,9 8,5 6, 2,2 20, 7,8 5,5 PD 2,99 2,,85,42 2,86 2,2,76,6 5,66 4,4,5 2,76 5, 4,5,2 2,6 5,47 4,22,6 2,6 5,09,9, 2,45 Hc 0, 8,97 7,98 6,99 0 8,74 7,77 6,8 8,8 6, 4,5 2,7 8,2 5,8 4, 2, 2,5 20,4 8,2 5,9 22,6 9,6 7,4 5, PD 8, 29,5 2,8 8,7 6, 28, 22,6 7,9 72,4 55,6 44,6 4, , 42 2,8 67,9 52,4 42,2 2,9 6,2 48,7 9 0,6 Hc 0,9 9,6 8,6 7,62 0,6 9,5 8,9 7,4 20 7,6 5,8 4 9,4 7, 5,,6 25,2 22, 9,8 7,5 24,2 2,2 9 6,8 PD 7,9 4,5 9,22 7,,4 8,79,7 26,4 2,6 7,2,7 24,8 20, 6,2 2, 25, 20,5 6,4 29,8 2, 9 5,2 Inlet/Outlet water H445 H4452 H Hc 2,4 2,6 20, 9 2, 9,7 8,5 7, 4,7 8,5 6,,7 7 4, 2 29,9 54,4 50,2 47 4,8 47,8 44 4,2 8,5 PD 4,6 2,7, 0 2,4 0,7 9,55 8,46,,5 0,2 8,96 0,7 9,6 8,4 7,8,5,6 0, 9,02 0,6 9,08 8,04 7,06 Hc 4, 2,5,2 9,92,,5 0,2 9,0 25,6 22,4 20 7,6 22,77 9,9 7,7 5,5,5 29, 26, 22,9 29,4 25,6 22,8 20 PD 6,4 5,2 4,2,7 5,5 4,4,57 2,8 5,7 4,47,69 2,92 4,6,64 2,95 2,4 5,69 4,44,57 2,8 4,47,46 2,8 2,8 Hc,7 2 0,7 9,8 2,5 0,9 9,7 8,5 24,4 2,2 8,9 6,6 2,5 8,7 6,7 4,6,6 27,5 24,4 2,4 27,6 24 2, 8,7 PD 72,4 56,8 45,9 6,5 6, 48 8,9 0,8 67, 5,7 4,9 5,5 4,,2 26,2 68,6 5 42,4,2 5,5 4 25,7 Hc 4,7 2,9,6 0,,4,8 0,6 9,42 26, 2 20,6 8, 2, 20, 8,2 6,2 4 29,8 26,8 2,7 29,7 26, 2,4 20,8 PD 4,9 27,8 2 8,6 29,5 2,6 9,5 5,8,9 25,2 20,6 6,6 25,5 20, 6,5,2 2,5 25,4 20,8 6,6 25, 9,9 6,2 2,9 7

8 Inlet/Outlet water H450 H4502 H Hc 28,6 26,9 25, 28,5 26, 24,7 2, 56,2 5,8 48,5 45,2 50,9 46,9 4,9 4 74, 68,4 64, 59,8 65,9 60,8 56,9 5, PD 7,9 6,84 6, 5,4 6,8 5,89 5,25 4,65 8,27 7, 6,28 5,52 6,87 5,9 5,22 4,62 2,8 9,74 8,56 0, 8,8 7,8 6,87 Hc 8,6 6,2 4, 2,5 7, 4,8,,4,7 29,2 25,8 22,4 0,5 26,4 2, 20, 45,8 40, 5,7, 40,7 5,5,7 27,8 PD,9 2,65 2,,66 2,92 2,27,8,42,7 2,59 2,07,59 2,79 2,4,7,4 5,46 4,27,44 2,7 4,9,42 2,77 2,7 Hc 8,4 6, 4, 2,5 6,9 4,7,,5,2 28,9 25,7 22,5 0 26, 2,2 20, 4, 7,5, 29,2 8,2,2 29,5 25,9 PD 40,,4 25,5 20,2 4,5 26,9 2,8 7, 4, 26,6 20,9 5,6 27, 22, 7,2 64,8 49,9 9,9,4 5,6 9, Hc 9,6 7,2 5,5,7 8 5,8 4,2 2,6 5,4, 27,9 24,7 2 28, 25,2 22, 46, 40,7 6,5 2,4 4, 6, 2,4 28,8 PD 9,2 5,2 2,6 0, 6,6, 0,9 8,69 20, 5,8 2,9 0, 6,7, 0,7 8,5 0,7 24, 9,7 5,7 24,5 9, 5,7 2,6 Inlet/Outlet water H46 H462 H Hc 45,4 4,9 9, 6,7 42,7 9,4 7 4,5 84,2 77,7 72, , 69,2 64,9 60, ,5 9,4 85,4 89, 82, PD 6,89 5,94 5,28 4,65 6,6 5,2 4,72 4,6 4, 2, 0,7 9,4, 9,74 8,6 7,59 2,5 8, 6,2 4, 5,5,,8 0,4 Hc 26,9 2, 20,6 7,8 25, 2,9 9, 6,7 5,4 44,9 40, 5 45,8 40, 5,5, 66, 58,2 52, 46, 56 49,2 44 8,9 PD 2,79 2,4,7,2 2,5,9,5,9 5,8 4,52,67 2,84 4,69,66 2,92 2,29 9,2 7,26 5,94 4,76 6,74 5, 4,,4 Hc 27,2 2,7 2 8,5 25,5 22,2 9,8 7, 49,5 4, 8,,6 44 8, 4, 29,9 / 5, 47, 4,5 5, 44,5 9,7 4,9 PD 6, 28, 22,7 7,9 2,4 25, 20, 5,9 7,6 56,5 45, 5, 58,8 45,2 6, 28,5 / 82,5 66,5 52,2 76,9 59,2 47,7 7,6 Hc 28,8 25, 22,7 20, 27, 2,8 2,4 8,9 52,9 46,6 4,8 7, 47, 4,4 7,2 65,8 57,9 52, 46, 55, 48,7 4,8 8,9 PD 7,4 8,75 5, 2 9,77 7,8 4, ,6 27,6 2,6 7,7 4, 50,9 40, 2,8 26, 6,8 28,9 2,8 9 Hc: heating capacity (kw) PD: Water pressure drop (kpa) * Only available in HEE version 8

9 Inlet/Outlet water Axial air heaters HELIOTHERME Performance Chilled water and reversible 20V/Ph/50Hz Motor AC and HE H402* H45 H440 H445 H450 H46* temperature ( C) Hc 7, 5,8 4,8,9 2,4 9,7 8,5 7,2 28,9 26,6 24,9 2,2 40,6 7,4 5, 2,8 54,9 50,6 47,4 44, 82 75,7 7 66,4 PD 42,7 6,8 2,7 28,9 5,2 4,5 4,5 7,2 6,2 5,5 4,8 7,8 6,7 6 5,2 7, 6, 5,6 4,9,2,4 0, 8,9 Hc 0,7 9,4 8,46 7,52 2,8, 9,8 8,6 7, 5,,7 25 2,9 9,5 7,,9 29,6 26,4 2,2 5,6 45,4 40,6 5,9 PD 8,4 4,6 2 9,65 2,,6, 2,,9,5, 2,6 2,,7, 2,4 2,6 5,8 4,6, Hc 2,5 0,9 9,7 8,5 6,8 4,6,4 2,5 20,5 8,2 6,7 27,6 24,6 2,6 46 4, 6,6 2,2 PD 27,6 2, 6,9, 6,6 28,4 22,7 7,8 9,4 0,6 24,5 9,2 6,5 28, 22,8 7,9 44,9 5, 4,2 2,4 Inlet/Outlet water H402* H45 H440 H445 H450 H46* Relative humidity 50% Relative humidity 50% Relative humidity 50% Relative humidity 50% Relative humidity 50% Relative humidity 50% temperature ( C) temperature ( C) temperature ( C) temperature ( C) temperature ( C) temperature ( C) Tcc 2,95,65 4,59,8 4,28 5,6 4,6 5,9 7,64 7, 8,87,6 9,66 2, 5,7 5,2 9, 24,4 72 Scc 2,95,5,99,8 4,28 5,7 4,6 5,85 6,98 7, 8,67 0,2 9,66,8,7 5,2 8,2 20,8 PD 24,4 6, 55 2,4,69 6,22,46 5,55 9,08 4,44 6,75, 4,22 6,55 0,7 8,46, 20,6 8 2,69,28 4,06 2,96,9 4,9 4,04 5, 6,7 6,9 8,08 0,2 8,66 0,9,9,8 7, 2,7 8 Scc 2,69,24,75 2,96,9 4,78 4,04 5, 6,46 6,9 8,02 9,47 8,66 0,9 2,9,8 6,8 9,6 PD 20,4 29,5 4,8,82, 4,86 2,68 4,5 7,06,6 5,65 8,76,4 5,7 8,52 6,98 0,6 6,5 Tcc 2,5 2,7, 2,6,,99 2,92 4,22 5,4 4,84 6,54 8,9 6,55 8,86, 0,8 4 7, 05 Scc 2,5 2,7,26 2,6,,99 2,92 4,22 5,4 4,84 6,54 8,2 6,55 8,86 0,8 4 6,9 PD,4 20,6 29,7 0,99,98,22,4 2,92 4,74 2,,75 5,79 2,0,57 5,5 4,8 7, 0,7 Hc: Heating capacity (kw) TCC: total cooling capacity SCC: sensible cooling capacity (kw) PD: Water pressure drop (kpa) *: Only available in HEE version 9

10 HELIOTHERME performance Hot water 400V/Ph/50Hz motor Inlet/Outlet water H45 H452 H Hc,9 0, 9,62,2 0, 9,69 9,05 2,7 20 8,7 7,4 9,7 8, 7 5,9 26,6 24,5 22,9 2,4 2,7 2,8 20,4 9 PD 7,92 6,86 6,2 5,4 7,09 6,4 5,48 4,84 8,9 7,04 6,2 5,48 6,86 5,89 5,22 4,6 8,04 6,86 6,07 5, 6,42 5,49 4,86 4,24 Hc 7, 6,2 5,5 4,78 6,7 5,8 5,7 4,49, 9,98 8,67,8 0,2 9,04 7,87 5,9,8 2,2 0,7 4, 2, 0,8 9,47 PD,8 2,6 2,,66,0 2,6,9,48,5 2,57 2,06,59 2,79 2,5,7,4,5 2,4,9,5 2,5,9,55,2 Hc 7,08 6,8 5,5 4,82 6,66 5,8 5,6 4,5 2,8,2 9,92 8,69,6 0, 9 7,88 5,6,6 2, 0,6,8 2 0,7 9,6 PD 40,5,7 25,7 20, 6, 28, 22,9 8, 42,8 26,8 20,7 5,6 27,5 22,2 7, 42 2,4 25,7 20,5 25,6 20,4 5,8 Hc 7,5 6,6 5,95 5,28 7,08 6,2 5,59 4,96,7 2 0,8 9,5 2,4 0,9 9,77 8,66 6,7 4,7,,6 4,8,7 0, PD 9, 5, 2,7 0,2 7,,7, 9, 20 5,7 2,8 0,2 6,7, 0,7 8,55 9,5 5,2 2, 9,79 5,5 2, 9,82 7,82 Inlet/Outlet water H440 H4402 H Hc 6,9 5,6 4,6,6 6, 4,8,9,9 29,4 27,5 25,7 29,9 27,5 25,8 24, 9,8 6,6 4, 2 6,8,8,7 29,5 PD 7,0 6,04 5,7 4,74 6,8 5,5 4,9 4,,9,9 0,5 9,24 2,2 0,5 9, 8,8,,2 9,92 8,76, 9,69 8,6 7,55 Hc 0 8,65 7,64 6,6 9,5 8,2 7,26 6,29 9, 6,9 5, 8, 5,8 4, 2, 24 20,8 8,4 6 22, 9,2 7 4,8 PD 2,9 2,2,79,7 2,65 2,0,6,27 5,66 4,4,5 2,76 4,99,92, 2,45 5,9 4,6, 2,59 4,66,58 2,88 2,26 Hc 0, 8,8 7,8 6,86 9,6 8,7 7,44 6,52 8,8 6, 4,5 2,7 7,6 5,,6,9 2, 20, 8 5,8 2,5 8,7 6,6 4,6 PD 6,8 28,5 2 8,, ,4 72,4 55,6 44,6 4,8 6,6 49,2 9,4 0,8 66,9 5,6 4,6 2,4 57,6 44,5 5,7 28 Hc 0,7 9,42 8,45 7,48 0,2 8,96 8,0 7, 20 7,6 5,8 4 8,8 6,5 4,8, 25 2,9 9,6 7,4 2, 20,2 8, 6, PD 7,,6, 8,9 5,7 2,4 0, 8,,7 26,4 2,6 7,2 29,8 2, 9, 5,2,6 24,7 20,2 6, 27,4 2, 7,4,9 Inlet/Outlet water H445 H4452 H Hc 2,7 2,9 20,6 9,2 2 9,4 8,2 7 44,2 40,8 8,2 5,7 9,2 6,2,9,7 57,4 52,9 49,6 46,2 49,8 45,9 4 40, PD 4,9,6 0,2 2 0,4 9,24 8,9 4,8 2,7, 9,96,9 0,2 9,08 8,0 5 2,8, 9,97,5 9,84 8,7 7,65 Hc 4,5 2,7,4 0, 2,8, 0, 8, ,7 2,2 8,7 24, 2, 8,8 6,5 5, 0,9 27,5 24, 0,7 26,8 2,9 20,9 PD 6,58 5,24 4,,45 5,2 4,2,46 2,74 6, 4,99 4,08,27 5, 4,04, 2,6 6,27 4,89,95, 4,84,76,0 2,7 Hc,9 2, 0,8 9,5 2, 0,7 9,54 8,8 25,8 22,5 20 7,5 22,9 9,9 7,7 5,5, ,8 22,6 28,9 25, 22, 9,6 PD 74,2 58,2 47, 7,4 59, 46,4 7,7 29,9 74,7 57,9 46,6 6,6 59,8 46,2 7,2 29,2 76,5 58,7 47 6,7 58, 44,7 5,9 28 Hc 4,9,,8 0,5,,6 0,4 9,25 27,7 24, 2,9 9,4 24,5 2,6 9,4 7,2 5,8,5 28, 25,, 27, 24,5 2,7 PD 5,7 28,5 2,6 9, 28,6 22,8 8,8 5, 5,4 28 2, 8,5 28,4 22,5 8,4 4,9 5,9 28, 2 8, 27,4 2,6 7,6 4 0

11 Inlet/Outlet water 4540 Axial air heaters H450 H4502 H Hc,7 29,2 27,4 25,6 28,6 26,4 24,8 2,2 57,4 52,9 49,5 46, , 76,4 70,4 65,9 6,6 65,7 60,6 56,7 5 PD 8,2 7, 6, 5,6 6,84 5,9 5,29 4,68 8,6 7,8 6,54 5,74 6,9 5,9 5,25 4,65,5,6 0, 9,0 0,2 8,76 7,6 6,8 Hc 9 6,5 4,6 2,7 7,2 4,9,2,5 4,4 29,8 26,4 22,9 0,6 26,5 2,4 20, 47, 4,2 6,8 2, 40,6 5,5,6 27,7 PD,5 2,75 2,2,7 2,94 2,28,84,4,5 2,69 2,5,65 2,8 2,6,72, 5,75 4,49,67 2,86 4,7,4 2,76 2,6 Hc 8,8 6,4 4,6 2,8 7 4,8,2,6,9 29,5 26,2 2 0, 26,2 2, 20,4 44,4 8,6 4, 0, 8,, 29,5 25,8 PD 4,9 2,6 26,4 20,9 4,8 27, 22 7,5 44,8 4,5 27,7 2,7 5,8 27,5 22,2 7, 68,5 52,7 42,, 5, 9,7,8 24, Hc 20 7,6 5,8 4 8, 5,9 4, 2,7 6,2,7 28,5 25,2 2, 28,2 25, 22,4 47,7 4,9 7,6, , 28,7 PD 9,9 5,8 0,5 6,7,2 0,9 8,77 2 6,4,5 0,7 6,8, 0,7 8,57 2,4 25,4 20,8 6,6 24,4 9,2 5,7 2,5 Inlet/Outlet water H46 or 46S H462 H Hc 46,5 42,9 40,2 7,5 44, 40,7 8, 5,6 87,9 8 75,9 70,9 80,8 74,5 69,8 65, , ,2 86,5 80,8 PD 7,9 6,2 5,5 4,85 6,5 5,62 4,99 4,4 5,,,6 0,2,2 9,9 8, ,5 8,2 6 9,2 6,5 4,6 2,9 Hc 27,6 2,9 2 8,2 26, 22,6 9,9 7,2 5,5 46,8 4,8 6,5 49, 4, 8,,5 70 6,7 55,4 49, 62,7 55, 49,5 4,7 PD 2,9 2,24,78,8 2,64 2,02,6,25 6,27 4,88,96,07 5,7 4,9,6 2,6 0,2 8, 6,6 5, 8,6 6,56 2,7 4,26 Hc 27,8 24,2 2,5 8,9 26, 22,9 20,4 7,9 5, , 47,4 4, 6,8 2,2 / 56,4 50,2 44, 57,6 50, 44,6 9,2 PD 7,9 29,4 2,7 8,6 4, 26,6 2,5 6,9 79,8 6,2 49,2 8,4 67,9 52,2 4,9 2,8 / 92,9 74,5 58, 96,6 74,2 59,5 46,7 Hc 5,7 25,9 2, 20,6 6,4 24,6 22 9,5 2, 48,6 4,6 8,7 24,5 44,6 40, 5,6 29,9 6,5 55, 49,,6 54,7 49,2 4,8 PD 7,7,9,5 9,2 6 2,6 0, 8, , 2,8 9,6 24,8 20, 6,2 56,9 44,8 6,8 29,4 45,6 6, 29,5 2,8 Hc: Heating capacity (kw) PD: Water pressure drop (kpa)

12 Electric motor specifications Use Model Motor HEATING HEATING COOL ING HEATING COOL ING H450 H4400 TPL4400 H4450 TPL4450 H4500 TPL4500 H460 TPL460 THREEPHASE 20/400V Ph 50Hz PH 20V Ph 50Hz AC Rotation speed Rpm Nom. current A Max power input (W) ê 85 0, ,5 70 ê 404 0, , 70 ê 85, ,64 80 ê 9, ,9 520 ê 870, 590 IP Thermal cutout YES 6. A 65 C Class F Operating temp 40 C / +60 C 40 C / +70 C 750 0,6 250 H , C / +60 C H/TPL , 00 YES H/TPL ,0 480 F A 65 C 40 C / +70 C H/TPL ,78 60 H/TPL ,6 580 H , C/+60 C H ,5 0 YES F H , A 65 C 40 C/+70 C H H460 HEE FMA H , PTC B 25 C/+60 C H , PTC B 25 C/+60 C H/TPL , Thermal cutout B 25 C/+60 C H/TPL , Thermal cutout B 25 C/+60 C H/TPL , Thermal cutout B 40 C/+60 C H/TPL , Thermal cutout B 40 C/+60 C PH 20V Ph 50/60Hz HEE H , PTC B 25 C/+60 C H , PTC B 25 C/+60 C H , Thermal cutout B 25 C/+60 C H , Thermal cutout B 25 C/+60 C H , Thermal cutout B 25 C/+60 C H , Thermal cutout B 25 C/+60 C Coil specifications LOW PRESSURE WATER COIL HP OIL/WATER COIL HP STEAM COIL Number of heating rows Number of cooling rows 2 Coil capacity (L) 0,8 0,68,8,66 0,96,59 2,28,8 2,27,22 2,8,8 4,55 2,97 4,7 6,4 Connection diameter ½ ¾" " ¼ Connection type Threaded unions 24 GCU F/M Maximum operating pressure 8 bar Test pressure 24 bar Max T 0 C Number of heating rows Coil capacity (L),9,69 2,66,69 Connection diameter.7 mm 42.4 mm 42.4 mm Connection type Smooth steel tube for welding Maximum operating pressure 6 bar Test pressure 24 bar Max T 200 C Number of heating rows Coil capacity (L) 0,97,22,95 2,86 Connection diameter 26.9 mm.7 mm 48. mm Connection type Smooth steel tube or stainless steel tube for welding Maximum operating pressure 8 or 6 bar Test pressure 24 bar Max T 70 C/200 C Version in stainless steel or with Heresite coating available upon request. Contact our sales network. 2

13 Dimensions HELIOTHERME B D C A B C D Size mm A H400 H450 H4400 H4450 H4500 H460 H460S Weight (kg) STD HEE row 2 rows rows TPL DESTRATIFIER C X Y Weight (kg) TPL A B TPL TPL4450 STD HEE TPL TPL Installation Min 0.5 m MIN 0.5 m mini Max 2.5 m 4.5 m mini Max 4.5 m 0 m Min 0.45 m mini Max 5 m 5 m Axial air heaters

14 Assembly accessories A different assembly for each use. RETURN AIR MODULE Size A B C Codes Size A B C Codes * DIFFUSION MODULE Size A B C Codes Size A B C Codes 400 Filter box (G filter in accordance with EN 779) Prevents premature clogging of exchanger coils Not ductable 2channel mixing box with builtin filter Adjusts the supply of fresh air to levels required by current regulations and mixes it with return air. Builtin G filter and connecting flange for cubic ducts. Air access sides configurable onsite. * not available for the 460S Diffuser on door Create an air curtain that limits energy loss when doors are opened. Warning: Use a system that is suited to the diffuser mounting. C B A ASSEMBLY SUPPORT ACCESSORIES Size Codes Wall bracket All to to Size DUCT ACCESSORIES Size A B C Codes Codes All Diffuser for large spaces Reduction cone for increasing the air throws. Additional kit for fastening on an IPN Suspension support for ceiling mounting Antifreeze damper 4

15 Electrical accessories Use ELECTRICAL & USER SAFETY Codes Circuit breaker unit FMA PH heating Padlockable proximity switch Available in a or 2speed version, this accessory must be placed at least 2 metres from any rotating part, to comply with French standard IT 246, Art. 47, and EC requirements. Circuit breaker unit HEE FMA PH heating Circuit breaker unit FMA PH cooling Circuit breaker unit HEE FMA PH cooling Circuit breaker unit PH H H H H H H TPL TPL TPL TPL THERMOSTATS Codes Codes Manual/auto room thermostat SINGLEPHASE installation : speed HEE thermostat kit (for HEE SINGLEPHASE FMA) Heating and cooling with manual toggle switch Inductive breaking capacity.5a : speed AC thermostat kit (for AC SINGLEPHASE FMA) Heating and cooling with manual toggle switch Inductive breaking capacity.5a IP54 industrial environment thermostat THREEPHASE installation 75: stage 76: 2 stages SUPPLY AIR SPEED SELECTION Codes / switch For phase motor, selects two motor rotation speeds and stop. Codes Autotransformer with selector switch (.5 A) Adjusts the voltage on singlephase motors with one variable speed to achieve up to five supply air speeds

16 HEE Singlephase HELIOTHERME control HEE PH BOX range, controls 6 Heliotherme units or 6 TPL or Heliotherme units + TPL Figure A FMA 00V control FMA FMA Supply 20 V /50 Hz VALVE 24 Vac power supply VALVE 00V control 20 V/50 Hz mains supply Singlephase HELIOTHERME control Eco+ PH BOX range Figure B 00 V valve 24 Vac valve Variable voltage 00 V valve 24 Vac valve Variable voltage 24 Vac valve 00 V valve Variable voltage Junction box (not supplied by CIAT) Water control not obligatory 24 Vac valve Builtin room sensor (optional remote sensor available 5 m) 220/24 VAC transformer 20 V/50 Hz mains supply 6

17 HELIOTHERME PH control (diagram in Eco+ PH BOX user manual) PH Eco+ BOX range Figure C Multiple junction box PH 400 V + T + N /50 Hz RS485 connection Slave unit: PH 400 V + T + N /50 Hz supply Master controller: Selfpowered by a fourwire (2 V) RS485 bus Figure D Slave unit: PH 400 V + T + N /50 Hz supply Master controller: Selfpowered by a fourwire (2 V) RS485 bus HELIOTHERME PH control (diagram in Eco+ PH BOX user manual) PH Eco+ BOX range with fresh air control Figure E 2way mixing box Fresh air kit (Damper Servomotor + frost protection thermostat) Slave unit Master controller 7

18 Allelectric HELIOTHERME control (diagram in Eco+ ELEC BOX user manual) Eco+ ELEC BOX range Figure F Slave unit Master controller Technical specifications of the different controllers HELIOTHERME or TPL CONTROL AND ACCESSORIES PH ECO + BOX with fresh CONTROL HEE Mono Box Ph ECO+ BOX unit PH ECO + BOX with BMR ECO + ELEC BOX air control Figure A B C and D E F Function Number of heliotherms or TPL that can be controlled to 6 to to 9 to to Protection rating Weekly timer (Comfort/ECO/frost protection) INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED Supply Voltage/Phase/Frequency 20 V//50Hz 20 V//50Hz 400 V//50Hz+N 400 V//50Hz+N 400 V//50Hz+N Electrical protection (circuit breakers, connectors, disconnectors) INCLUDED TO BE FITTED INCLUDED INCLUDED INCLUDED Air control Proportional 0 0V Proportional 0 20V 2speed / 2speed / speed or Water control Proportional 0 0V Proportional 0 0V Proportional 0 0V Proportional 0 0V Integrated temperature sensor INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED Remote on/off switch and fault summary INCLUDED NOT INCLUDED NOT INCLUDED NOT INCLUDED NOT INCLUDED MODBUS/LON and BACnet IP communication OPTION NO NO NO NO Fresh air control YES NO NO YES NO Accessories BOX CONTROL Slave unit for Eco+ PH BOX BMR Eco+ PH BOX Multiple connection unit (controls max. units) Eco+ ELEC BOX slave unit 9.6 KW (for H450 TE PH) Eco+ ELEC BOX slave unit 8.9 KW (for H4400 TE PH) Eco+ ELEC BOX slave unit 28.8 KW (for H4500 TE PH) Eco+ ELEC BOX slave unit 4.2 KW (for H4500 TE PH) 7289 ½ " valve kit KV.6 (H400) B4020 ¾ " valve kit KV 2.5 (H ) ¾ valve kit KV 4 (H ) B40040 B4004 ½ valve kit KV 6. (H ) B40042 ½ valve kit KV 0 (H46246) B /24 Vac safety transformer INCLUDED INCLUDED INCLUDED (required for the electrical feed of the valve servomotor(s) (00V) Changeover switch thermostat (for automatic SummerWinter changeover) Padlockable proximity switch 6P for PH Eco+ BOX INCLUDED INCLUDED Padlockable proximity switch P for MONO or HEE Eco+ Box Remote sensor Fresh air kit (includes a damper servomotor and a frost protection thermostat) B40044 B

19 HELIOTHERME... is also the solution for ATEX compliance Ex II 2 G/D II c 65 C 05 C or 20 to 220 C EEx d/de IIB or IIC T4 to T6 IP 6X/5X T C CIAT has put all its expertise and knowhow into a special series of ATEX certified HELIOTHERME units. This approval, issued by an independent external body, is your guarantee of complete compliance with the ATEX directives. The ATEX HELIOTHERME range is certified for your applications: n In the presence of explosive gas or dust n In Zone or 2 n For IIB or IIC explosion groups n With T4 to T6 gas autoignition temperatures n Low pressure water, superheated water, steam, oil, compressed air etc. What is ATEX? ATEX or explosive atmosphere can be caused in atmospheric conditions by flammable gases, vapours or mists or by combustible dusts mixed with air. After ignition, combustion spreads through the whole of the unburnt mixture. How is an ATEX zone defined? ATEX zones are determined based on the probability and duration of the occurrence of an explosive atmosphere. This risk analysis enables zones, the explosion groups and maximum surface temperature classes to be defined. Such atmospheres are mainly found in paint workshops, metal processing workshops, waste recycling, wood processing, etc. Who defines ATEX zones? Any operator of a production facility where an explosive atmosphere may occur must define the relevant ATEX zones, explosion groups and temperature classes. By doing so, the operator will also be able to set up the necessary means of prevention (communication, documentation, recommendations, etc.). "ive 94/9/EC divides the equipment and protective systems which it covers into equipment groups and categories; this ive (999/92/EC) provides for a classification by the employer of the places where explosive atmospheres may occur in terms of zones and determines which equipment and protective systems groups and categories should be used in each zone." ZONE Gas (G) Dust (D) Category The explosive agent is: Occurs continuously, often and over extended periods: NOT APPLICABLE TO ANY CIAT PRODUCTS 2 Occasionally present during normal use Rarely or briefly present GAS EXPLOSION GROUP AND TEMPERATURE CLASS Temperature class T T2 T T4 T5 T6 Max surface temp 450 C 00 C 200 C 5 C 00 C 85 C Explosion group Acetone Ammonia Benzene IIA Acetic acid Petrol Ethane iamyl acetate Diesel Ethyl acetate Butane Hot oil Ethyl chloride Butyl alcohol Hexane Methanol Acetaldehyde Naphthalene Phenol Propane II B Town gas Ethylene Hydrogen sulphide Ethyl ether II C Hydrogen Acetylene Carbon disulphide 9

20 Codes Model SINGLE PHASE HEATING SINGLE PHASE HEE HEATING Standard version SINGLE PHASE COOLING SINGLE PHASE HEE COOLING Water / LP Oil PH Stainless steel options (available at additional cost) Coil Heating Casing Cooling H402 Code B40209 B4020 B40204 H45 Code B40000 B H452 Code B4000 B H45 Code B40002 B B H440 Code B40009 B H4402 Code B B H440 Code B40004 B B H445 Code B B40000 H4452 Code B B40000 H445 Code B B40000 B4000 H450 Code B B4000 H4502 Code B B4000 H450 Code B B4000 B40004 H46 Code B B40006 H462 Code B B40006 H46 Code B B40006 B40007 Model Standard version SINGLE PHASE Superheated water / Oil Stainless steel options (available at additional cost) PH Coil Casing Standard version SINGLE PHASE Steam Stainless steel options (available at additional cost) PH Coil Casing H45 Code B40000 B B4000 B H440 Code B40009 B B B H450 Code B B B B4000 H46 Code B B B B40006 Electrical Model SINGLE PHASE Standard version PH Stainless steel casing option H kw Code B H kw Code B H kw Code B kw Code B40005 Options available at additional cost (H4000 with AC FMA) Size CORROBLOC motor option PH 400 V 6P ATEX motor option SINGLE PHASE PH IIB T4 IIC T4 IIB T5 IIC T6 H450 Code B4009 B4002 B B B B H4400 Code B40022 B40024 B B B B H4450 Code B40025 B40027 B B B B H4500 Code B40028 B4000 B B B B H460 Code B400 B400 20

21 TàP ANGLAIS This document is noncontractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office 700 Avenue Jean Falconnier B.P Culoz France Tel.: + (0) Fax: + (0) Certified Management System Compagnie Industrielle d Applications Thermiques S.A. with a registered capital of R.C.S. BourgenBresse B

42AM. Air heaters PRODUCT SELECTION DATA

42AM. Air heaters PRODUCT SELECTION DATA PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of

More information

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation The most competitively priced technical solution for heating large spaces New H400 model New HEE control Ensures buildings warm up ultra fast Excellent diffusion via patented JET+ double deflection technology

More information

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly

More information

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision

More information

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw. Slim design and acoustic comfort Saves up to 40% floor space Capacity up to 50 kw Free cooling Water misting Use Drycoolers in this range are mainly designed for cooling water or glycol/water mix for:

More information

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

CLIMACIAT AIR COMPACT

CLIMACIAT AIR COMPACT Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000

More information

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling MORE n More efficient n More flexible n More intelligent for LESS n Less energy n Less time n Less noise Capacity: up to 1100 kw 410A 407C 134a 404A Free cooling Water misting Use The range, available

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability. Protecting installations Energy optimisation Improved profitability Flow rate of conditioned biogas: up to 6 000 Nm 3 /h Biogas efficient waste recovery Operating principle When produced, biogas contains

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit AHU for all applications Designed to meet the EN 13053 and EN 1886 standards The effective solution for service sector, industry and healthcare applications air HanDLIng UnIT: CLIMaCIaT represents the

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control. Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept

More information

Implementation of ATEX Guidelines

Implementation of ATEX Guidelines Implementation of ATEX Guidelines Temperature and Climatic Test Chambers for Usage under Conditions Carrying a Risk of Fire and Explosion What are ATEX guidelines? Introduction Duties of the system user...

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

ECOCIAT. Domestic hot water heat recovery unit. Use. Range Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS For a print friendly page click here INTRODUCTION Hazardous areas are those in which there exists a risk of explosion

More information

Compact and silent Scroll compressors All-season operation

Compact and silent Scroll compressors All-season operation Compact and silent Scroll compressors All-season operation Cooling capacity: 40 to 161 kw 410a Cooling only Use The new generation of CONDENCIAT condensation units is the solution for all split-system

More information

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION KNX PID control system on water Wall terminal with dial Wall terminal with display Radio-frequency remote control Available in the second quarter of 2008 Factory-recessed thermostat New-generation networked

More information

KPSW CONSOLE TERMINAL UNIT

KPSW CONSOLE TERMINAL UNIT TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November 008 0 7 - GB - 0 MARKING This product marked conforms to the essential

More information

VSD AND SS DRIVING ATEX MOTORS February 2014

VSD AND SS DRIVING ATEX MOTORS February 2014 VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment

More information

WOLF VENTILATION SYSTEM PRICE LIST

WOLF VENTILATION SYSTEM PRICE LIST VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h KOG LN Low Noise Chilled Water Cassettes 09, 12 & 18 1.70 to 6.10kW 1.58 to 5.10kW 330 to 920 m3/h KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Cassette units Model Comfort Circle. - heating - cooling - ventilation Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their

More information

Vertical self-contained air conditioner

Vertical self-contained air conditioner Compact and sleek Broad range of functions and performance Energy efficient (EC motor) and self-regulating control Easy to install ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Precision air handling cabinets Ciatronic MICRO/EXPAIR / Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers : SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish

More information

CAW Ceiling-mounted fan heaters for hot water

CAW Ceiling-mounted fan heaters for hot water Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot ceiling-mounted fans are used for heating entrances, warehouses, industrial premises, workshops,

More information

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain Air curtains 114 MRX condensing gas air curtain 118 MRA-H gas air curtain 121 MRA-A ventilation only air curtain 122 SW / SE hot water / electrical air curtain 124 SWR / SER built-in hot water / electrical

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

System architecture. Air treatment Index

System architecture. Air treatment Index System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

Energy-efficient heat source provides comfort in large rooms

Energy-efficient heat source provides comfort in large rooms AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating

More information

Explosion-proof Duct Heaters

Explosion-proof Duct Heaters Safety INDEECO explosion-proof ULTRA-SAFE and EP2 duct heaters are Factory Mutual (FM) and CSA Approved. The ULTRA-SAFE duct heater has the only standard product offering and features the industry s lowest

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C u n i v e r s a l c o m f o r t Precision air-handling cabinets CIATRONIC System Ultimate precision air-conditioning NA 05.93 C > > CIATRONIC System Precision air- > CIAT, European leader in air-conditioning

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as

More information

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool Hazardous Area Classification in Oil & Gas Industry A Fire Prevention Tool SFPE ENGINEERING TECHNOLOGY CONFERENCE Oct 4, 2010 New Orleans, LA 1 Overview Oil and gas plants handle flammable materials 2

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Air Conditioning SABIANA ENVIRONMENTAL

More information

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

TERM-E ELECTRIC HEATING AND VENTILATION UNITS ELECTRIC HEATING AND VENTILATION UNITS INTENDED USE The heating units with axial fans, metal casing and electric heaters are designed to heat rooms such as: industrial halls, workshops, warehouses, commercial

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation BTBa CEILING UNIT FLUSHLINE BTBa FLUSHLINE BTBa is a complete climate system offering immense flexibility. Ideal for large areas with

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

[ TECHNOLOGY ] and does this definition affect a burner.

[ TECHNOLOGY ] and does this definition affect a burner. [ TECHNOLOGY ] JBD-11,500-G type burner for natural gas ATEX, EExd Zone 2. For combined cycle power plant in Riga Latvia. Aitor Fernández Project Engineer Automation Department Head afernandez@emcombustion.es

More information

WOLF WARM AIR CURTAIN

WOLF WARM AIR CURTAIN TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring

More information

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545 NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions

More information

Unit heater with accessories

Unit heater with accessories LVD Unit Heater Unit heater with accessories The type LVDV fan-assisted unit heaters are designed for space heating in shop entrances, lobbies, doorways, warehouses and workshops, garages and similar premises.

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

INDUSTRIAL AIR CURTAIN. IndAC 2

INDUSTRIAL AIR CURTAIN. IndAC 2 INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

NEW RANGE OF WARM AIR CURTAINS

NEW RANGE OF WARM AIR CURTAINS NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

Halton Rex for Vario R6O - Variable air volume chilled beam

Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited

More information