360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle"

Transcription

1 AUTO ILLE ELEVATION GR ED CAN BE LOWER UP TO 4M Better Design Super slim design, perfect for tight roof spaces 360 round flow, ensuring uniform airflow distribution across the room Independent louvre control allows each louvre to be set at the desired angle Auto elevation grille can be lowered automatically up to 4m, for easy filter cleaning or maintenance Better Installation Twin system option allows for two indoor units of the same capacity to connect to one outdoor unit, for better air distribution in large zones Reserved air outlets allow duct connection to other rooms Drain pump fitted as standard for convenience Remote on/off and alarm output connection on PCB Fresh air intake option, for healthier living and light commercial applications AACORP0138 v2_arbs Handout_Residential Products 210x297.indd 1 13/05/ :28 am

2 Cassette Split System - Single Phase ( kW) Technical Information OUTDOOR MODEL URC-053AS URC-071AS URC-100AS URC-125AS URC-140AS INDOOR MODEL CRE-053AS CRE-071AS CRE-100AS CRE-125AS CRE-140AS Nett (Rated) Capacity (kw) Input Power (kw) Cooling Heating Cooling Rated Heating Rated EER Cooling Rated COP Heating Rated Star Rating Cooling Heating Power Supply - (V / Ph / Hz) Outdoor 220V - 240V / 1Ph + N / 50Hz Rated Load Amps Cooling Heating Full Load Amps Suggested Circuit Breaker Amps Moisture Removal (L/hr) Outdoor Dimensions (mm) Indoor/Panel Dimensions (mm) Nominal Weight (kgs) Indoor Sound Pressure Level Outdoor Sound Outdoor Operating Range ( C) High Medium Low Depth Height Width Depth 840/ / / / /950 Height 205/55 245/55 245/55 245/55 287/55 Width 840/ / / / /950 Outdoor Indoor 22/5 24/5 27/5 29/5 29/5 Turbo/High/Med/Low/ Quiet - (dba) 49/44/39 49/45/41 52/49/45 53/49/45 54/51/48 Pressure Level - (dba) Power Level - (dba) Cooling Heating -15 C to 50 C -15 C to 24 C Field Piping and Connections Compressor Rotary Rotary Rotary Rotary Scroll Refrigerant Refrigerant Charge Pre-Charge Length - (m) Field Pipe Length Maximum - (m) Maximum Vertical Height Differential - (m) included in max length Field Pipe Size R410a Liquid Pipe - mm (inch) 6.35 (1/4 ) 9.52 (3/8 ) 9.52 (3/8 ) 9.52 (3/8 ) 9.52 (3/8 ) Gas Pipe - mm (inch) 12.7 (1/2 ) 15.9 (5/8 ) 15.9 (5/8 ) (3/4 ) (3/4 ) Drain Pump Standard Standard Standard Standard Standard Wiring Method Interconnecting Cable 2 Core + Earth 2 Core + Earth 2 Core + Earth 2 Core + Earth 2 Core + Earth

3 Better Design Elegant, modern appearance with matte finish External on/off button in the absence of a remote Sturdy outdoor unit designed to withstand the harsh Australian environment Wide compressor frequency range, for smooth and accurate control DC indoor fan with twelve fan speeds, for precise airflow control and comfort DC outdoor fan with five fan speeds, for better comfort and energy savings Low ambient cooling down to -15 C The most superior operating range on the market, from -25 C 50 C Better Installation Installation template for perfect alignment New mounting plate design with allowance of up to 50mm horizontal movement Installation lift support brackets to assist with installation Increased visual space, for easier pipe connection Ease of wiring, through increased internal space and larger wiring terminals

4 Wall Hung Split System - Single Phase ( kW) Technical Information OUTDOOR MODEL WRC-026AS WRC-035AS WRC-050AS WRC-071AS WRC-080AS INDOOR MODEL WRE-026AS WRE-035AS WRE-050AS WRE-071AS WRE-080AS Nett (Rated) Capacity (kw) Input Power (kw) Cooling Heating Cooling Rated Heating Rated EER Cooling Rated COP Heating Rated Star Rating Cooling Heating Power Supply - (V / Ph / Hz) Outdoor 220V - 240V / 1Ph + N / 50Hz Rated Load Amps Cooling Heating Full Load Amps Suggested Circuit Breaker Amps Moisture Removal (L/hr) Outdoor Dimensions (mm) Indoor Dimensions (mm) Nominal Weight (kgs) Indoor Sound Pressure Level Outdoor Sound Outdoor Operating Range ( C) Turbo High Medium Low Quiet Depth Height Width Depth Height Width Outdoor Indoor Turbo/High/Med/Low/ Quiet - (dba) 43/42/37/32/28 45/43/38/31/28 45/44/42/37/29 49/47/44/36/32 49/47/44/38/34 Pressure Level - (dba) Power Level - (dba) Cooling Heating -15 C to 50 C -25 C to 30 C Field Piping and Connections Compressor Rotary Rotary Rotary Rotary Rotary Refrigerant Refrigerant Charge Pre-Charge Length - (m) Field Pipe Length R410a Minimum - (m) Maximum - (m) Maximum Vertical Height Differential - (m) included in max length Field Pipe Size Wiring Method Liquid Pipe - mm (inch) 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 9.52 (3/8") 9.52 (3/8") Gas Pipe - mm (inch) 9.52 (3/8") 12.7 (1/2") 12.7 (1/2") 15.9 (5/8") 15.9 (5/8") Interconnecting Cable 3 Core + Earth 3 Core + Earth 3 Core + Earth 3 Core + Earth 3 Core + Earth

5 CONNECT UP TO 5 HEADS TO 1 OUTDOOR UNIT Better Design Universal wall split design offers more flexibility Wide compressor frequency range, for smooth and accurate control DC outdoor fan with five fan speeds, for better comfort and energy savings Low ambient cooling down to -15 C Sturdy outdoor unit designed to withstand the harsh Australian environment Better Installation Connect up to five indoor heads to one outdoor unit, saving space and hassle Choose between wall splits or bulkheads to fit your desired installation Auto check and correction function for wiring and piping allows for a quicker, more reliable install Bulkheads fitted with drain pump as standard for convenience Fresh air intake option, for healthier living and light commercial applications Single service valve, for better installation and maintenance AACORP0138 v2_arbs Handout_Residential Products 210x297.indd 5 13/05/ :28 am

6 Multi Split System - Single Phase ( kW) Technical Information OUTDOOR MODEL MRC-052AS-2 MRC-075AS-3 MRC-100AS-4 MRC-110AS-5 MRC-135AS-5 Max. No. of Indoor Heads Nett Capacity (kw) Cooling Heating Input Power (kw) Cooling Rated Heating Rated EER Cooling Rated COP Heating Rated Power Supply - (V / Ph / Hz) Outdoor 220V - 240V / 1Ph + N / 50Hz Depth Outdoor Dimensions (mm) Height Width Nominal Weight (kgs) Outdoor Outdoor Sound Pressure Level - (dba) Power Level - (dba) Refrigerant R410a Refrigerant Charge Pre-Charge Length - (m) Field Pipe Max. Length Total One Indoor Unit Field Pipe Size Maximum Vertical Height Differential - (m) included in max length Outdoor Operating Range ( C) Liquid Pipe - mm (inch) 2 x 6.35 (1/4") 3 x 6.35 (1/4") 4 x 6.35 (1/4 ) 5 x 6.35 (1/4 ) 5 x 6.35 (1/4 ) Gas Pipe - mm (inch) 2 x 9.52 (3/8") 2 x 9.52 (3/8 ) 1 x 12.7 (1/2 ) 3 x 9.52 (3/8 ) 1 x 12.7 (1/2 ) 4 x 9.52 (3/8 ) 1 x 12.7 (1/2 ) 3 x 9.52 (3/8 ) 2 x 12.7 (1/2 ) OU higher than IU OU lower than IU C to 50 C -15 C to 24 C Bulkhead Indoor Unit Bulkhead BRE-026AS BRE-035AS BRE-052AS Nett Capacity (kw) Cooling (min - max) Heating (min - max) High Medium Low External Static Pressure (Pa) Rated Range Depth Indoor Dimensions (mm) Height Width Nominal Weight (kgs) Indoor Sound Pressure Level (dba) High / Med / Low 36/33/30 39/36/34 42/39/37 Pipe Size Liquid Pipe - mm (inch) 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") Gas Pipe - mm (inch) 9.52 (3/8") 9.52 (3/8") 12.7 (1/2") Wall Hung Split Indoor Unit Bulkhead WRE-026AS WRE-035AS WRE-050AS WRE-071AS Nett Capacity (kw) Cooling (min - max) Heating (min - max) Turbo High Medium Low Quiet Depth Indoor Dimensions (mm) Height Width Nominal Weight (kgs) Indoor Sound Pressure Level (dba) Pipe Size Turbo/High/Med/Low/ Quiet - (dba) 43/42/37/32/28 45/43/38/31/28 45/44/42/37/29 49/47/44/36/32 Liquid Pipe - mm (inch) 6.35 (1/4") 6.35 (1/4") 6.35 (1/4") 9.52 (3/8") Gas Pipe - mm (inch) 9.52 (3/8") 12.7 (1/2") 12.7 (1/2") 15.9 (5/8")

7 Better Design Ultra slim design that is only 248mm high, perfect for tight roof spaces High static pressure up to 160Pa, for better air flow with long duct runs Quiet and smooth operation Easy access for service and maintenance Better Installation Auto air volume optimisation during commissioning, saving you time Interchangeable return air intake from rear to bottom option, to suit your installation Drain pump fitted as standard for convenience Fresh air intake option, for healthier living and light commercial applications AACORP0138 v2_arbs Handout_Residential Products 210x297.indd 7 13/05/ :28 am

8 Low Profile Ducted Split System - Single Phase ( kw) Technical Information OUTDOOR MODEL URC-071AS URC-100AS INDOOR MODEL LRE-071AS LRE-100AS Nett (Rated) Capacity (kw) Cooling Heating Input Power (kw) Cooling Rated Heating Rated EER Cooling Rated COP Heating Rated Power Supply - (V / Ph / Hz) Outdoor 220V - 240V / 1Ph + N / 50Hz Rated Load Amps Cooling Heating Full Load Amps Suggested Circuit Breaker Amps Moisture Removal (L/hr) High Medium Low External Static Pressure (Pa) Rated Range Depth Outdoor Dimensions (mm) Height Width Depth Indoor/Panel Dimensions (mm) Height Width Nominal Weight (kgs) Outdoor Indoor Indoor Sound Pressure Level Turbo/High/Med/Low/Quiet - (dba) 43/40/38 45/41/38 Outdoor Sound Pressure Level - (dba) Power Level - (dba) Outdoor Operating Range ( C) Cooling -15 C to 50 C Heating -15 C to 24 C Field Piping and Connections Compressor Rotary Rotary Refrigerant R410a Refrigerant Charge Pre-Charge Length - (m) Field Pipe Length Maximum - (m) Maximum Vertical Height Differential - (m) included in max length Field Pipe Size Liquid Pipe - mm (inch) 9.52 (3/8") 9.52 (3/8") Gas Pipe - mm (inch) 15.9 (5/8") 15.9 (5/8") Drain Pump Standard Standard Wiring Method Interconnecting Cable 2 Core + Earth 2 Core + Earth