Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Size: px
Start display at page:

Download "Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center"

Transcription

1 Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch REFRIGERATIVE SUPPLY #04 (18852) 2885 Quesnel Street VICTORIA, BC V8T 4K2

2 Project Name : Fuller Lake Arena VRF Management Number : Building : Created by : Steve Chamut Company : Refrigerative Supply Address : stevec@rsl.ca 1.Material list 1.1.Material list Series:VRF system Model Quantity Type AOUA168TLBVG 1 VR-II Heat Recovery ASUA9TLAV 5 Wall mounted ASUA12TLAV 3 Wall mounted ASUB18TLAV 2 Wall mounted ASUB24TLAV 2 Wall mounted UTY-DTGYZ1 1 Touch panel controller(internet access) UTY-RNRUZ1 12 Wired RC(Touch) Z1 UTP-BX180A 2 Separation tube UTP-DX567A 1 Outdoor unit branch kit UTP-RU04BH 3 RB unit 1.2.Material List 2 (Pipe) Series:VRF system Pipe length(ft) 1/4 3/8 1/2 5/8 3/4 7/8 1-1/8 Total Material List 3 (Calculation of additional charge refrigerant) Series:VRF system Refrigerant lbs R410A 33.8

3 2.Indoor unit details 2.1.Table of abbreviations Name Local name of the device HC Available heating capacity (with defrost compensation) Model Device model name Airflow Supplied airflow at low and high fan speed RC C Rated cooling capacity ESP External static pressure RC H Rated heating capacity Sound Sound pressure low and high Tmp C Indoor condition in cooling MCA Minimum Circuit Amps Rq TC Required cooling capacity HxWxD Height x Width x Depth TC Available total cooling capacity Weight Weight of the device Rq SC Required sensible cooling capacity Dis Tmp C Discharge temperature at cooling SC Available sensible cooling capacity Dis Tmp H Discharge temperature at heating Tmp H Indoor temperature in heating HE Heat exchanger volume Rq HC Required heating capacity (with defrost compensation) Rated Rated current 2.2.Otdr1 (VRF system) - AOUA168TLBVG Name Model RC C (Ton) RC H (Ton) Tmp C (F/%) Rq TC (Ton) TC (Ton) Rq SC (Ton) SC (Ton) Tmp H (F) Rq HC (Ton) HC (Ton) EU-1 ASUB18TLAV / EU-2 ASUB18TLAV / EU-3 ASUA12TLAV / EU-4 ASUA9TLAV / EU-5 ASUA9TLAV / EU-6 ASUB24TLAV / EU-7 ASUB24TLAV / EU-8 ASUA9TLAV / EU-9 ASUA9TLAV / EU-10 ASUA9TLAV / EU-11 ASUA12TLAV / EU-12 ASUA12TLAV / Name Model Airflow (cfm) EU-1 ASUB18TLAV High EU-2 ASUB18TLAV High EU-3 ASUA12TLAV High EU-4 ASUA9TLAV High EU-5 ASUA9TLAV High EU-6 ASUB24TLAV High EU-7 ASUB24TLAV High EU-8 ASUA9TLAV High EU-9 ASUA9TLAV High ESP (WG) Sound (db) Rated (A) MCA (A) HxWxD (inch) /8 x 39-5/16 x /8 x 39-5/16 x /16 x 31-1/8 x 8-7/ /16 x 31-1/8 x 8-7/ /16 x 31-1/8 x 8-7/ /8 x 39-5/16 x /8 x 39-5/16 x /16 x 31-1/8 x 8-7/ /16 x 31-1/8 x 8-7/16 Weight (lbs) Image

4 EU-10 ASUA9TLAV High EU-11 ASUA12TLAV High EU-12 ASUA12TLAV High /16 x 31-1/8 x 8-7/ /16 x 31-1/8 x 8-7/ /16 x 31-1/8 x 8-7/

5 3.Outdoor unit details 3.1.Table of abbreviations Name Local name of the device Tmp H Outdoor temperature in heating(dry bulb) Model Device model name HC Heating capacity EER Energy efficiency rating MCA Minimum Circuit Amps COP Coefficient of Performance MFA Main fuse (circuit breaker) current RC C Rated cooling capacity HxWxD Height x Width x Depth RC H Rated heating capacity Weight Weight of the device Comb Combination percentage Refrig Standard factory refrigerant charge Tmp C Outdoor temperature in cooling(dry bulb) Rated C Rated current Cooling TC Available total cooling capacity Rated H Rated current Heating 3.2.Outdoor unit details Series:VRF system Name Model EER COP Comb (%) RC C (Ton) RC H (Ton) Tmp C (F) TC (Ton) Tmp H (F) HC (Ton) Otdr1 AOUA168TLBVG AOUA96TLBV AOUA72TLBV Name Model PS Rated C (A) Otdr1 AOUA168TLBVG 3Phase, 208V, 60Hz Rated H (A) MCA MFA HxWxD Weight Refrig (A) (A) (inch) (lbs) (lbs) Image AOUA96TLBV AOUA72TLBV 3Phase, 208V, 60Hz 3Phase, 208V, 60Hz /16x36-5/8x30-1/ /16x36-5/8x30-1/

6 4.Piping Diagrams 4.1.Piping Otdr1 (VRF system) Refrig R410A(lbs) 52.0 Add Refrig R410A(lbs) 33.8 Total Refrig R410A(lbs) 85.8

7 5.Wiring Diagrams 5.1.Wiring Otdr1 (VRF system) Airstage Project

8 5.2.Wiring Otdr1 (VRF system) Airstage Project

9 6.Options Otdr1 (VRF system) - AOUA168TLBVG Name Model Type Qty Model Type Qty EU-1 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-2 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-3 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-4 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-5 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-6 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-7 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-8 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-9 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-10 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-11 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-12 UTY-RNRUZ1 Wired RC(Touch) Z1 1

10 7.Piping / Branch kit / Header details 7.1.Branch kit details Series:VRF system Name Model UTP-BX180A UTP-DX567A Otdr1 AOUA168TLBVG Header details 7.3.Piping details Series:VRF system Name Model 1/4 3/8 1/2 5/8 3/4 7/8 1-1/8 Otdr1 AOUA168TLBVG Name Refrig R410A(lbs) Add Refrig R410A(lbs) Total Refrig R410A(lbs) Otdr Branch box details 7.5.RB details Series:VRF system Name Model UTP-RU01AH UTP-RU01BH UTP-RU01CH UTP-RU04BH Otdr1 AOUA168TLBVG DX Kit details

11 8.User option User options(project) User options(refrigerant) Airstage Project

12 9.Room list 9.1.Room list 9.2.Room-indoor list There are some differences between a calculated result and specification. Airstage Project

13 Job Name Location Engineer Submitted To Submitted By Reference Submittal AOUA72TLBV 6 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) 1X (AOUA72TLBV) Date Approval Construction Unit No Drawing No Inverter driven compressor New style high power DC fan motor. Blue fin heat-exchanger (Corrosion resistance) 10 Year warranty on parts and compressor. See Warranty Statement for details. Optional: Internet, BACnet, LonWorks, or Modbus communication. CAPACITY OPERATING TEMPERATURES Nominal Cooling Capacity - BTU/h [kw] 72,000 [21.1] Operating Temp. Cooling (DB) - F [ C] 14 to 115 [-10 to 46] Nominal Heating Capacity - BTU/h [kw] 81,000 [23.7] Operating Temp. Heating (DB) - F [ C] -4 to 70 [-20 to 21] Nominal Tonage - Ton(s) 6 Operating Temp. Cooling/Heating Simultaneous - F [ C] 14 to 70 [-10 to 21] Maximum Connectable Indoor Units 14 Connectable Capacity 50% to 150% EFFICIENCY Cooling Power Input - kw 5.31 EER Cooling (Ducted/Non Ducted) 12.3 / 12.5 Heating Power Input - kw 5.35 IEER Cooling (Ducted/Non Ducted) 20 / 24.1 Unit Group 1X (AOUA72TLBV) COP / High Heating 47 F 3.64 / 4.06 SCHE (Ducted/Non Ducted) 30.10/24.00 ELECTRICAL Voltage Range 187 to 253 VAC WIRING Maximum Circuit Breaker - A 50 Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Minimum Circuit Ampacity (MCA) - A 41 Cooling Power Input - kw 5.31 Heating Power Input - kw 5.35 PIPING Maximum Starting Current (MSC) - A 33.2 Max. Total Refrigerant Line Length - ft [m] 3,280 [1,000] Compressor - Rated Load Amperage (RLA) - A 17 PipeConnection:Max Height Diff. (ODU & ID)(Upper/Lower) - ft [m] 164/131 [50/40] Fan Motor - Full Load Amperage (FLA) - A 3.0 Pipe Connection Method: Liquid/Gas Brazed Pipe Connection: Liquid - in [mm] 1/2 [12.70] COMPRESSOR Pipe Connection: Discharge Gas - in [mm] 5/8 [15.88] Compressor Type Rotary Inverter Pipe Connection: Suction Gas - in [mm] 7/8 [22.22] Refrigerant Type R410A Refrigerant Charge - lbs [kg] [11.80] SOUND Compressor Crankcase Heater - W 2X 35 Sound Pressure Levels (Cooling/Heating) - db(a) 57 / 58 Refrigerant Oil / Lubricant POE Compressor Capacity Control - Steps/Range 951 / WEIGHT Net Weight - lbs [kg] 597 [271] FAN Gross Weight - lbs [kg] 642 [291] Fan Type Propeller fan Fan Airflow Rate - CFM [m3/h] 6,533 [11,100] DIMENSIONS Fan Power Output - W 740 Dim.Net (HxWxD) - in [mm] Fan Motor - Full Load Amperage (FLA) - A 3.0 External Static Pressure (Max) - in.wg [Pa] 0.32 [80] HEAT EXCHANGER Dim.Gross (HxWxD) - in [mm] 71-5/ / /8 H. E. Pipe Type (Material) Grooved H-pin (Copper) [ ] H. E. Fin Tube (Material) Corrugate (Aluminum) H. E. Fin Surface Treatment Corrosion resistance (Blue fin) H. E. Fin Pitch - FPI [mm] 18 [1.45] CODE H. E. Rows x Stages 3 x 60 ETL H. E. Face Area - Ft² [m²] 23 [2.2] AHRI Certified Standard 1230 H. E. Length - in [mm] 69-5/16 [1760] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 66-9/16 x 36-5/8 x 30-1/8 [1690 x 930 x 765] 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) Fax: (973)

14 Submittal AOUA72TLBV 6 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) DIMENSIONS Unit: In. (mm) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) Fax: (973)

15 Job Name Location Engineer Submitted To Submitted By Reference Submittal AOUA96TLBV 8 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA96TLBV) 1X (AOUA96TLBV) Date Approval Construction Unit No Drawing No Inverter driven compressor New style high power DC fan motor. Blue fin heat-exchanger (Corrosion resistance) 10 Year warranty on parts and compressor. See Warranty Statement for details. Optional: Internet, BACnet, LonWorks, or Modbus communication. CAPACITY OPERATING TEMPERATURES Nominal Cooling Capacity - BTU/h [kw] 96,000 [28.1] Operating Temp. Cooling (DB) - F [ C] 14 to 115 [-10 to 46] Nominal Heating Capacity - BTU/h [kw] 108,000 [31.7] Operating Temp. Heating (DB) - F [ C] -4 to 70 [-20 to 21] Nominal Tonage - Ton(s) 8 Operating Temp. Cooling/Heating Simultaneous - F [ C] 14 to 70 [-10 to 21] Maximum Connectable Indoor Units 16 Connectable Capacity 50% to 150% EFFICIENCY Cooling Power Input - kw 7.56 EER Cooling (Ducted/Non Ducted) 11.70/11.30 Heating Power Input - kw 7.82 IEER Cooling (Ducted/Non Ducted) 23.60/20.20 Unit Group 1X (AOUA96TLBV) COP / High Heating 47 F 3.72/3.60 SCHE (Ducted/Non Ducted) 26.50/25.50 ELECTRICAL Voltage Range 187 to 253 VAC WIRING Maximum Circuit Breaker - A 50 Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Minimum Circuit Ampacity (MCA) - A 41 Cooling Power Input - kw 7.56 Heating Power Input - kw 7.82 PIPING Maximum Starting Current (MSC) - A 33.2 Max. Total Refrigerant Line Length - ft [m] 3,280 [1,000] Compressor - Rated Load Amperage (RLA) - A 25 PipeConnection:Max Height Diff. (ODU & ID)(Upper/Lower) - ft [m] 164/131 [50/40] Fan Motor - Full Load Amperage (FLA) - A 3.0 Pipe Connection Method: Liquid/Gas Brazed Pipe Connection: Liquid - in [mm] 1/2 [12.70] COMPRESSOR Pipe Connection: Discharge Gas - in [mm] 3/4 [19.05] Compressor Type Rotary Inverter Pipe Connection: Suction Gas - in [mm] 7/8 [22.22] Refrigerant Type R410A Refrigerant Charge - lbs [kg] [11.80] SOUND Compressor Crankcase Heater - W 2X 35 Sound Pressure Levels (Cooling/Heating) - db(a) 59/59 Refrigerant Oil / Lubricant POE Compressor Capacity Control - Steps/Range 951 / WEIGHT Net Weight - lbs [kg] 597 [271] FAN Gross Weight - lbs [kg] 642 [291] Fan Type Propeller fan Fan Airflow Rate - CFM [m3/h] 6,533 [11,100] DIMENSIONS Fan Power Output - W 740 Dim.Net (HxWxD) - in [mm] Fan Motor - Full Load Amperage (FLA) - A 3.0 External Static Pressure (Max) - in.wg [Pa] 0.32 [80] HEAT EXCHANGER Dim.Gross (HxWxD) - in [mm] 71-5/ / /8 H. E. Pipe Type (Material) Grooved H-pin (Copper) [ ] H. E. Fin Tube (Material) Corrugate (Aluminum) H. E. Fin Surface Treatment Corrosion resistance (Blue fin) H. E. Fin Pitch - FPI [mm] 18 [1.45] CODE H. E. Rows x Stages 3 x 60 ETL H. E. Face Area - Ft² [m²] 23 [2.2] AHRI Certified Standard 1230 H. E. Length - in [mm] 69-5/16 [1760] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 66-9/16 x 36-5/8 x 30-1/8 [1690 x 930 x 765] 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) Fax: (973)

16 Submittal AOUA96TLBV 8 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA96TLBV) DIMENSIONS Unit: In. (mm) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) Fax: (973)

17 Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUA9TLAV Compact Wall (9,500 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 9,500 [2.8] Capacity - Heating - Btu/h [kw] 10,900 [3.2] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe MBH or More Input Power - W 18 Full Load Amps - FLA - A 0.41 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.51 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 294 [500] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 265 [450] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] Cololing 247 [420] / Heating 218 [370] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) (cooling-heating)/33/36 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 1/4 [6.35] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 1/2 [12.70] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 9/16 [14.3] Enclosure - Net Weight - lbs [kg] 20 [9] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 26 [12] Dimensions - Net (H x W x D) - in [mm] 10-13/ /8 8-7/16 [ ] ETL Dimensions - Gross (H x W x D) - in [mm] 11-7/ /8 13-9/16 E.T.L [ ] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

18 Submittal ASUA9TLAV Compact Wall (9,500 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

19 Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUA12TLAV Compact Wall (12,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 12,000 [3.5] Capacity - Heating - Btu/h [kw] 13,500 [4] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe MBH or More Input Power - W 22 Full Load Amps - FLA - A 0.41 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.51 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 330 [560] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 283 [480] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] 247 [420] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 31/35/39 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 1/4 [6.35] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 1/2 [12.70] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 9/16 [14.3] Enclosure - Net Weight - lbs [kg] 20 [9] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 26 [12] Dimensions - Net (H x W x D) - in [mm] 10-13/ /8 8-7/16 [ ] ETL Dimensions - Gross (H x W x D) - in [mm] 11-7/ /8 13-9/16 E.T.L [ ] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

20 Submittal ASUA12TLAV Compact Wall (12,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

21 Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUB18TLAV Wall (18,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 18,000 [5.3] Capacity - Heating - Btu/h [kw] 20,000 [5.9] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe MBH or More Input Power - W 32 Full Load Amps - FLA - A 0.42 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.53 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 494 [840] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 453 [770] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] 406 [690] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 35/39/41 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 3/8 [9.52] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 5/8 [15.88] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 1/2 [12] Enclosure - Net Weight - lbs [kg] 33 [15] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 42 [19] Dimensions - Net (H x W x D) - in [mm] 12-5/8 39-5/16 9 [ ] ETL Dimensions - Gross (H x W x D) - in [mm] 12-9/ / /8 E.T.L [319 1, ] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

22 Submittal ASUB18TLAV Wall (18,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

23 Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUB24TLAV Wall (24,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 24,000 [7.0] Capacity - Heating - Btu/h [kw] 27,000 [7.9] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe MBH or More Input Power - W 60 Full Load Amps - FLA - A 0.52 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.65 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 647 [1,100] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 536 [910] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] 430 [730] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 35/43/48 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 3/8 [9.52] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 5/8 [15.88] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 1/2 [12] Enclosure - Net Weight - lbs [kg] 33 [15] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 42 [19] Dimensions - Net (H x W x D) - in [mm] 12-5/8 39-5/16 9 [ ] ETL Dimensions - Gross (H x W x D) - in [mm] 12-9/ / /8 E.T.L [319 1, ] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

24 Submittal ASUB24TLAV Wall (24,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) Fax: (973)

25 Variable Refrigerant Flow System Submittal Data: UTP-BX180A Separation Tube 96,500 to 193,000 Btu /h Job Name: Location: Engineer: Submitted to: Submitted by: Separation Tube Date: Approval: Construction: Unit #: Drawing #: Reference: Separation Tube for 3 Pipes UTP-BX180A Port Dimensions Rev. date 06/01/15 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

26 Variable Refrigerant Flow System Submittal Data: UTP-BX180A Separation Tube 96,500 to 193,000 Btu /h Separation Tube Heat Insulation Dimensions Rev. date 06/01/15 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

27 UTP-DX567A Submittal Airstage Project Outdoor Unit Branch Kit Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #: Fujitsu General America, Inc. Toll Free: Fax: (973) Airstage.fujitsugeneral.com

28 Variable Refrigerant Flow System Submittal Data: UTP-RU04BH RB Unit Branch Box Job Name: Location: Engineer: Submitted to: Submitted by: Date: Approval: Construction: Unit #: Drawing #: Reference: General Features Small and slim design saves space Drain pipe not required The control box position can be changed to meet installation conditions Freedom to mount control box from either side Electrical /230V AC 1ph-60HZ Available Voltage Range / 253V AC Input Power W Running Current A PCB Fuse A x4 250V x4 Capacity Number of branches Maximum number of connected indoor units Maximum capacity of connectable indoor units ,000 Btu/h*1 Maximum capacity of connectable indoor units per branch ,000 Btu/h Refrigerant Type. R410A Connection Pipe Outdoor Unit Side Suction Gas Pipe /8 (28.58 mm) Discharge Gas Pipe /8 (22.22 mm) Liquid Pipe... 5/8 (15.88 mm) Indoor Unit Side Gas Pipe.... 3/4 (19.05 mm) Liquid Pipe /8 (9.52 mm) Method Brazing Wiring Communication Cable... LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Operation Temperature Range F F (-15 C - 46 C) Installation Locations.... Indoors only Dimensions H x W x D Uncrated in. (mm) /4 x 25-7/8 x 16-7/8 (260x658x428) Crated in. (mm /16 x 49-3/16 x 30-1/2 (348x1250x775) Weight Net lbs. (31.5 kg) Gross lbs. (39.5 kg) ETL ETL Number Unit in. (mm) 5-7/8 (150) Unit in. (mm) Rev. date 03/15/16 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

29 Job Name Location Engineer Submitted To Submitted By Reference Submittal AOUA168TLBVG 14 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) 1X (AOUA72TLBV) + 1X + 1X (AOUA96TLBV) (AOUA96TLBV) Date Approval Construction Unit No Drawing No Inverter driven compressor New style high power DC fan motor. Blue fin heat-exchanger (Corrosion resistance) 10 Year warranty on parts and compressor. See Warranty Statement for details. Optional: Internet, BACnet, LonWorks, or Modbus communication. Outdoor separation tube must be ordered separately (UTP-DX567A). CAPACITY OPERATING TEMPERATURES Nominal Cooling Capacity - BTU/h [kw] 168,000 [49.2] Operating Temp. Cooling (DB) - F [ C] 14 to 115 [-10 to 46] Nominal Heating Capacity - BTU/h [kw] 189,000 [55.1] Operating Temp. Heating (DB) - F [ C] -4 to 70 [-20 to 21] Nominal Tonage - Ton(s) 14 Operating Temp. Cooling/Heating Simultaneous - F [ C] 14 to 70 [-10 to 21] Maximum Connectable Indoor Units 26 Connectable Capacity 50% to 150% EFFICIENCY Cooling Power Input - kw EER Cooling (Ducted/Non Ducted) 11.0/11.0 Heating Power Input - kw IEER Cooling (Ducted/Non Ducted) 22.20/20.0 Unit Group 1X (AOUA72TLBV) + 1X (AOUA96TLBV) COP / High Heating 47 F 3.48/3.48 SCHE (Ducted/Non Ducted) 22.0/22.0 ELECTRICAL Voltage Range 187 to 253 VAC WIRING Maximum Circuit Breaker - A 2X (50) each Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Minimum Circuit Ampacity (MCA) - A 2X (41) Cooling Power Input - kw Heating Power Input - kw PIPING Maximum Starting Current (MSC) - A 2X (33.2) Max. Total Refrigerant Line Length - ft [m] 3,280 [1,000] Compressor - Rated Load Amperage (RLA) - A 1X (17) + 1X (25) PipeConnection:Max Height Diff. (ODU & ID)(Upper/Lower) - ft [m] 164/131 [50/40] Fan Motor - Full Load Amperage (FLA) - A 2X (1.5) Pipe Connection Method: Liquid/Gas Brazed Pipe Connection: Liquid - in [mm] 5/8 [15.88] COMPRESSOR Pipe Connection: Discharge Gas - in [mm] 7/8 [22.22] Compressor Type 2X Rotary Inverter Pipe Connection: Suction Gas - in [mm] 1-1/8 [28.58] Refrigerant Type R410A Refrigerant Charge - lbs [kg] 2X (26.01 [11.80]) SOUND Compressor Crankcase Heater - W 2X (2X 35) Sound Pressure Levels (Cooling/Heating) - db(a) 61 / 62 Refrigerant Oil / Lubricant POE Compressor Capacity Control - Steps/Range 951 / (per unit) WEIGHT Net Weight - lbs [kg] 2X (597 [271]) FAN Gross Weight - lbs [kg] 2X (642 [291]) Fan Type 2X Propeller fan Fan Airflow Rate - CFM [m3/h] 2X (6,533 [11,100]) DIMENSIONS Fan Power Output - W 2X (740) Dim.Net (HxWxD) - in [mm] Fan Motor - Full Load Amperage (FLA) - A 2X (1.5) External Static Pressure (Max) - in.wg [Pa] 0.32 [80] HEAT EXCHANGER Dim.Gross (HxWxD) - in [mm] 2X (71-5/ / /8 H. E. Pipe Type (Material) Grooved H-pin (Copper) [ ]) H. E. Fin Tube (Material) Corrugate (Aluminum) H. E. Fin Surface Treatment Corrosion resistance (Blue fin) H. E. Fin Pitch - FPI [mm] 18 [1.45] CODE H. E. Rows x Stages 2X (3 x 60) ETL H. E. Face Area - Ft² [m²] 2X (23 [2.2]) AHRI Certified Standard 1230 H. E. Length - in [mm] 2X (69-5/16 [1760]) Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 2X (66-9/16 x 36-5/8 x 30-1/8 [1690 x 930 x 765]) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) Fax: (973)

30 Submittal AOUA168TLBVG 14 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) + 1X (AOUA96TLBV) DIMENSIONS Unit: In. (mm) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) Fax: (973)

31 Variable Refrigerant Flow System Submittal Data: UTY-DTGYZ1 Job Name: Location: Engineer: Submitted to: Submitted by: Touch Panel Controller (with Internet Communication) Date: Approval: Construction: Unit #: Drawing #: Reference: General Features Electrical Power AC volts 1ph-50/60HZ Input Power... 22W Fuse Capacity.. 5A Display Screen inch TFT color LCD display (640 x 480 pixels), with Touch panel Temperature Cooling Setting Range F - 88 F (18 C - 30 C) Heating Setting Range F - 88 F (10 C - 30 C) Humidity range... 0 to 85% (no condensation Ethernet RJ45 External Interface External In.. (Either emergency stop or batch stop operation/stop) External Out... (Operation state, error state) USB Port..USB 2.0 Dimensions H x W x D In (mm) 10-1/4 x 9-11/16 x 2-1/8 (260 x 246 x 54) Weight... 5lbs. (2150 g) Maximum Controllable Indoor Units Heat-Pump indoor units Heat-Recovery 320 indoor units Touch panel controller with built-in Internet output provides VRF remote monitoring and control capability. The VRF system can be remotely monitored and controlled via LAN or WAN from remote PC with an Internet Browser. It can be used to control the cooling & heating, ON/OFF, Auto, Fan speed, Temperature setting, Air flow direction, Timer set-up for up to 24hr in advance. Up to 16 UTY-DTGYZ1 touch panel controllers can be connected per VRF system. Can control and monitor up to 400 Indoor units. Can control and monitor up to 100 Outdoor Units. Error contents are notified automatically by to be handled promptly. Equipped with LCD touch panel screen and stylish shape and design. Programmable in 7 different languages: English, Chinese, French, German, Spanish, Russian & Polish. FEATURES Automatic clock and summer time adjustment Outdoor Unit low noise setting function Easy Operation Wide range of easy to understand icons Finger or dedicated touch pen selections Two background colors identifying the control operation blue for monitoring & green for operational control Function Individual control Flexible grouping Schedule control Indoor units control & monitoring Versatility Emergency stop function Stored data can be transferred via the Internet and USB port CSV format data edited by PC can be imported to the to the Touch Panel Controller Easy Installation No external 4x4 box is required. Mounts flush to wall. OPTIONAL: Electricity charge apportionment function can be added purchasing UTY- PTGXA. In addition a pulse electric meter is required to measure the Outdoor Unit power consumption. Rev. date 8/09/16 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

32 Variable Refrigerant Flow System Submittal Data: UTY-DTGYZ1 Touch Panel Controller (with Internet Communication) Dimensions Terminal Names Names of connection terminals inside rear cover. External Inputs Terminal External input terminals are available for all ON/OFF and Emergency stop commands. Rev. date 8/09/16 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

33 Submittal UTY-RNRUZ1 Wired Remote Controller (Touch Panel) Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Date: Approval: Construction: Unit #: Drawing #: General Features Wired touch screen remote controller with backlight that connects to the VRF indoor units using 2-wires. Individual or group control of up to 16 indoor units. Temperature Setting Range Cooling F ( C) (18-30) Heating F ( C ) (10-30) Weight and Dimensions Weight oz (g).. 8 (220g) Dim.Net (HxWxD) in(mm) /4x4-3/4x11/16 (120x120x20.4) Electrical Input Voltage DC V. 12 Power consumption W. Max 0.3 Wire Size AWG (mm²) 22 to 16 (0.33 to 1.25) Non polar 2 core sheathed twisted pair cable Thermostat Wiring AWG (mm²) 18 (0.75) 2 core sheathed non twisted pair cable Display. 3.8 inch backlight LCD Touch display (255x160 dots) Operation modes: Auto/Cool/Dry/Fan/Heat Various timer setup (on/off/weekly) are possible Auto ON or OFF timer this feature is used to start/stop the indoor unit operation for early boost/startup or early shutdown. Weekly timer: a. Start/stop function twice per day b. Operating time can be set in 30-minute increments c. The OFF timer can be carried over to the next day Vacation schedule Built-in Temperature sensor. Sensing can be set to measure temperature at the Remote or at Indoor unit. Additional Custom Settings: - Set temperature Auto Return - Set temperature Range Setting, - Away Setting, - Error History, - Anti Freeze, - Filter Reset, - R.C. Master/Slave Setting, - Language Setting. This remote controller is compatible with all VRF A***TLAV indoor units. This remote controller is not compatible with all VRF A***RLAV indoor units. Rev. 9/20/16 1 of 2 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

34 Submittal UTY-RNRUZ1 Wired Remote Controller (Touch Panel) DIMENSIONS (a) (b) (c) (d) (a) (b) (c) (d) Room temperature sensor Operation (occupied/unoccupied) button LED lamp (operation indicator) Touch panel display Rev. 9/20/16 2 of 2 Fujitsu General America, Inc. 353 Route 46 West Toll Free: Fax: (973)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase 208/230V, 1-Phase 208/230V, 460V 3-Phase 208/230V, 460V 3-Phase Heat Pump Heat Pump Heat Recovery 208-230V 1-Phase 208-230V 3-Phase, 460V 3-Phase 208-230V 3-Phase, 460V 3-Phase Airstage VRF systems provide

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of5 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Modules Connected US Ton (nominal) Capacity (Btu/h) System Specifications

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Power Indoor Units Modules Connected US Ton (nominal) Capacity

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Engineering Data Book

Engineering Data Book 40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Engineering Data Book

Engineering Data Book 40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

Engineering Data Book

Engineering Data Book 40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule # Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Page 1 of 7 Performance Power Compressor 95 F Ambient, Entering Temperature: 54 F, Leaving

More information

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

Engineering Data Book

Engineering Data Book 40VMU Under Ceiling/Floor Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

Increase your flexibility.

Increase your flexibility. DVM CHILLER Increase your flexibility. Get the best of two worlds. This easy to expand, modular unit combines the benefits of VRF and Chiller systems. Product Registration Required Conditions Apply 2018

More information

16 SEER TWO-STAGE AIR CONDITIONERS

16 SEER TWO-STAGE AIR CONDITIONERS FORM NO. ATZ-210 Supersedes Form No. ATZ-210 16 SEER TWO-STAGE AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability

More information

Engineering Data Book

Engineering Data Book 40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7 P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS

More information

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control... R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7 P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)

More information

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION What is Daikin VRV IV S-series? One flexible package Daikin VRV IV S-series

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 8129 VARIABLE REFRIGERANT A. Variable refrigerant volume HVAC system includes: 1. Outdoor/condensing unit(s). 2. Indoor/evaporator units. 3. Branch selector

More information

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference: M-SERIES SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: MSY-GL24NA Outdoor Unit: MUY-GL24NA Wireless Remote Controller

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Unit Features & Benefits RQPM/RQRM Series

Unit Features & Benefits RQPM/RQRM Series 2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable

More information

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference: M-SERIES SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: MSY-GL12NA Outdoor Unit: MUY-GL12NA Wireless Remote Controller

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM Job Name: System Reference: : Date: : PUY-A24NHA7 PUY-A24NHA7-BS INDOOR UNIT FEATURES Unobtrusive ceiling-concealed

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information