EPCEN General CATALOGUE Air Conditioning Systems

Size: px
Start display at page:

Download "EPCEN General CATALOGUE Air Conditioning Systems"

Transcription

1 EPCEN General CATALOGUE 2007 Air Conditioning Systems

2

3 Foreword FIRST IN QUALITY MANUFACTURING Since coming to Ostend (Belgium) in 1973, we have transformed our manufacturing plant into one of the most advanced air conditioning facilities in Europe. This capacity has recently been further supplemented by two thoroughly modern plants in Plzen and Brno in the Czech Republic. All of our plants profit from Daikin s policy of zero-defect manufacturing and optimal supply chain management, allowing us to supply you with the quality products you need, when you need them. FIRST IN PRODUCT INNOVATION AND CONCERN FOR THE ENVIRONMENT Using the latest technologies incorporating high efficiency and relentless concern for the environment, we are able to offer a highly competitive and diversified product range that has made Daikin the air conditioning leader in Europe. In this, we have been able to profit from the considerable experience of Daikin Industries Ltd., our parent company in Japan, which for longer than anyone else has been at the leading edge of developing new and efficient technologies that respect the environment. FIRST IN CUSTOMER SERVICE Daikin understands the needs of the local markets. We have wholly owned subsidiaries in the UK, Spain, Germany, Italy, France, Belgium, Portugal, Poland and Central Europe, as well as partly owned and independent distributors throughout Europe, Africa and the Middle East. This allows us to tailor our product offerings to each region and to respond quickly and efficiently to these fast-growing markets. Thus, the products contained in this catalogue are designed to represent the best possible answer to your air conditioning needs. Feel free to contact your local Daikin representative for further information and assistance. We are here to serve you! 1

4 Daikin Europe N.V. Table of Contents Foreword 1 Table of contents 2 Environmental awareness 4 Energy labeling 6 2

5 Air Purifier Photocatalytic air purifier 8 Residential & Commercial Wall mounted units 12 Flexi type units 36 Floor standing units 42 Concealed ceiling units 44 Cassette units 66 4-Way blow ceiling suspended cassettes 84 Ceiling suspended units 88 Twin/triple/double twin applications 99 Multi model applications 110 Altherma 121 Air handling unit connections 125 Rooftop units 128 VRV VRVIII-S 132 VRVIII air-cooled outdoor units 134 VRVII air-cooled outdoor units 140 VRV-WII water-cooled outdoor units 141 Indoor units 143 Selection programmes 157 HRV 158 Control Systems Centralised control systems 162 Network Solutions 163 Applied Systems Air-cooled 170 Water-cooled 193 Fan coil units 202 To consult the explanation of the pictogrammes,please refer to page 205 of this catalogue. 3

6 Environmental Awareness AIR CONDITIONING AND THE ENVIRONMENT Air conditioning systems provide a significant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a significant contribution to limiting the impact on the environment. 4

7 DAIKIN S COMMITMENT TO THE ENVIRONMENT The pioneering concern for the environment and natural resources is a part of the entire global Daikin operation at all levels: from product design, manufacturing processes, down to the responsibility each individual Daikin employee takes for the environment. This commitment is reflected in three areas: reducing waste in manufacturing and operations, recycling materials, and designing and producing energy-efficient climate control equipment. REDUCING WASTE IN MANUFACTURING AND BUSINESS OPERATIONS In 1998, Daikin Europe N.V. became the first air conditioning manufacturer in Europe to obtain ISO environmental certification. In addition, since 2004, not only the manufacturing plants but Daikin sales companies as well have obtained ISO certification, underlining Daikin s commitment to the environment at all levels of our organisation. These certified environmental plans include the reduction of waste at all levels. Our environmental targets are high: Daikin Europe N.V. is committed to a zero waste policy whereby as much as possible of its by products can be reused, recycled or recovered as useful resources. RECYCLING MATERIALS Daikin Europe N.V. is firmly committed to recycling materials in all areas of its operations. Wastewater is treated before being discharged into the city drainage system, with the recovered sludge being a useful ingredient in cement manufacturing. Other waste is also carefully sorted and recycled, supported by a continually evolving factory layout that encourages the optimum use of resources. In addition to recycling, we invest significantly in returnable packaging. The same high demands are also imposed on our suppliers. Eliminating waste and optimum recycling reduce raw material consumption and contribute to efficient manufacturing and operating processes, meaning fewer burdens on the environment. ENERGY EFFICIENT CLIMATE CONTROL EQUIPMENT Daikin s commitment to being a leader in environmental developments has led to a string of innovations in climate control equipment: Daikin s use of inverter technology for example reduces start-up time by 33% and allows the compressor to consume only the power it actually needs to meet the cooling/heating needs of the moment. Linking the use of inverter technology to reluctance DC compressor motors has further improves efficiency, allowing Daikin units to obtain the highest efficiency ratings in the market. Daikin also produces computerised air conditioning monitoring and control systems designed to ensure maximum energy efficiency at all times, such as Daikin s latest I-controller technology which offers customers refined and energy efficient control of Daikin heat recovery air conditioning installations, including remote monitoring via the Internet. This list of innovations could be expanded endlessly. More importantly, it clearly demonstrates that technological innovation and concern for the environment can go hand in hand. At Daikin, these environmental priorities form an integral part of our corporate culture and are reflected in all of our products. Choosing Daikin means you can be sure that the cooling systems you use are the safest possible for the environment. 5

8 Energy Labeling Energy labeling is part of a wider European Climate Change program that targets energy efficiency as one method of reducing CO2 emissions in order to meet the targets of the Kyoto protocol. By this means the European Commission hopes that improved awareness will result in customers purchasing the most economical (ecological) answer to their needs. Energy Manufacturer Outside unit Inside unit More effi cient Less efficient A B C D E F G Annual energy consumption, kwh in cooling mode (Actual consumption will depend on how the apliance is used and climate) Cooling output Energy effi ciency ratio Full load (the higher the better) Type Cooling only Cooling + Heating Air cooled Water cooled Heat output Heating performance A: higher G: lower Noise (db(a) re 1 pw) kw kw WHAT? The energy label provides information on the energy consumption of the unit. Air conditioning units (with cooling capacity 12kW) are classified in seven different categories (A to G), according to their energy consumption and color coded according to the category to which they belong. The most energy efficient units will be included in the A category, indicated by a green arrow on the label less efficient units will belong in G class, indicated by a red arrow on the label. The end user can easily compare the efficiency of equal types of units from different brands. THE LABEL? WHAT IS MENTIONED ON THE LABEL? Logo and name of manufacturer; name of indoor and outdoor unit (*) Energy efficiency class of the unit in cooling mode: A EER 3.20 B 3.20 EER 3.00 C 3.00 EER 2.80 D 2.80 EER 2.60 E 2.60 EER 2.40 F 2.40 EER 2.20 G 2.20 EER Further information is contained in product brochures Air-conditioner Energy Label Directive 2002/31/EC 6

9 INDICATED ANNUAL ENERGY CONSUMPTION This figure indicates the approximate amount of energy consumed per year by the unit, based on a standard household model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year IN COOLING MODE AT FULL LOAD. In order to calculate the cost of annual energy consumption, you merely multiply this figure by your electricity tariff. COOLING OUTPUT Cooling output is defined as the cooling capacity in kw of the appliance, operating in cooling mode at full load. It is important to choose an air conditioning unit with a rated output sufficient for your cooling/heating requirements. An oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer. ENERGY EFFICIENCY RATIO (EER) This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input). In other words, the higher the EER, the greater the energy efficiency. TYPE TYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating system COOLING MODE: it indicates if the unit is air cooled or water cooled HEATING OUTPUT Heating output is defined as the heating capacity in kw of the appliance, operating in heating mode at full load. ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE: A EER 3.60 B 3.60 EER 3.40 C 3.40 EER 3.20 D 3.20 EER 2.80 E 2.80 EER 2.60 F 2.60 EER 2.40 G 2.40 EER Noise level: only for portable units. (*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units (wall mounted type) - for other units we refer to the multi brochure. 7

10 MC707VM-W MC707VM-S Photocatalytic air purifier IMPROVED OUTLOOK IMPROVED PERFORMANCES MORE COMFORT New design aiming to suit better in any interior décor. Two different colour options: white or silver Due to the Daikin Flash Streamer technology: - a bigger number of allergens are resolved - adjuvant* decomposition performance improved - deodorising and disinfecting power increased (*Adjuvant substances are substances that adhere to allergens, making them even more harmful, e.g. diesel exhaust particles.) Extended applicable room size = up to 48m 2 Quiet operation: 16dB(A) in silent mode Pre-filter (with catechin) Removes large dust particles and pet hairs. Bio-antibody filter Airborne viruses are captured and removed. Plasma ionizer Dust and pollen are positively charged and sent to the electrostatic filter. Dirty air 8

11 MC707VM-W MC707VM-S MC707VM-W/S Model MC707VM-W/S Power supply 1~, / V, 50/60Hz Dimensions HxWxD mm 533x425x213 Colour (W) = White + sparkling silver or (S) = Sparkling silver + metallic ocean blue Weight Kg 8.7 Mode (50Hz) Turbo H M L Silent Power input kw Sound pressure level db(a) Sound power level db(a) Air fl ow rate m 3 /h Dust collecting method Plasma ionizer (electrostatic dust collection) + Electrostatic dust collection fi lter Deodorising Method Flash Streamer + Titanium apatite photocatalytic fi lter + Deodorising catalyst Deodorising performance (%) 95 Regenerate method The Flash Streamer activates the photocatalytic reaction Bacteria fi ltering method Bio-Antibody fi lter + Flash Streamer + Titanium apatite photocatalytic fi lter Filter Dust Form Pleated fi lter collection and Function Deodorisation + disinfection + dust collection + adjuvant removal deodorisation Lifetime 1 fi lter/1 year Bio-Antibody fi lter New Pre-fi lter Catechin pre-fi lter new Flash Streamer unit Flash Streamer High-speed electrons are generated by the Flash Streamer. These electrons powerfully break down odours and formaldehyde. Electrostatic dust collection filter Positively charged dust and pollen are adsorbed by the negatively charged filter. Front Deodorising catalyst Odours are adsorbed and broken down before the air is returned into the room. Purified air Back Titanium Apatite Photocatalytic Filter Odour, bacteria and viruses are adsorbed and decomposed. 9

12 10

13 Daikin residential air conditioning is the modern, economic and efficient way to switch on to springtime - in the living room, dining room, kitchen or bedroom, night and day, throughout the year. Daikin air conditioning units are easy to install, easy to use, ultra reliable, quiet running and come in an elegant and up to date range of wall, floor and ceiling mounted indoor models. Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the residential market today. Inverter control cuts start up time and energy consumption by almost a third, alters unit output to suit outdoor conditions, improves performance relative to power input, ensures a more even room temperature and eliminates power surges and stop/start cycles. Residential & Commercial 1. Wall mounted units FTXR-E / RXR-E 13 FTXG-E / RXG-E 15 FTKS-DW / RKS-E 16 FTKS-DW / RKS-F 17 FTXS-DW / RXS-E 18 FTXS-DW / RXS-F 19 FTKS-DL / RKS-E 20 FTKS-DL / RKS-F 21 FTXS-DL / RXS-E 22 FTXS-DL / RXS-F 23 FTKS-C / RK-E 24 FTXS-C / RX-E 25 FTKS-F / RKS-F 26 FTXS-F / RXS-F 27 FTN-D / RN-D 28 FTYN-D / RYN-D 29 FTN-F / RN-E 30 FTYN-F / RYN-E 31 FAQ-B / RR-B 32 FAQ-B / RQ-B 33 FAQ-B / RZQS-B 34 FAQ-B / RZQ-B/C Flexi type units FLKS-B / RKS-E 36 FLKS-B / RKS-F 37 FLKS-B / RN-E 38 FLXS-B / RXS-E 40 FLXS-B / RXS-F Floor standing units FVXS-F / RKS-F 42 FVXS-F / RXS-F Concealed ceiling units FDKS-E / RKS-E 44 FDKS-C / RKS-F 45 FDXS-E / RXS-E 46 FDXS-C / RXS-F 47 FBQ-B / RKS-E 48 FBQ-B / RKS-F 49 FBQ-B / RXS-E 50 FBQ-B / RXS-F 51 FBQ-B / RN-E 52 FBQ-B / RR-B 53 FBQ-B / RQ-B 54 FBQ-B/ REQ-B 55 FBQ-B / RZQS-B/C 56 FBQ-B / RZQ-B/C 57 FDQ-B / RR-B 58 FDQ-B / RQ-B 59 FDQ-B / RZQS-B 60 FDQ-B / RZQ-B/C 61 FDEQ-B / REQ-B 62 FDYP-B / RP-B 64 FDYP-B / RYP-B Cassette units FFQ-B / RKS-E 66 FFQ-B / RKS-F 67 FFQ-B / RXS-E 68 FFQ-B / RXS-F 69 FFQ-B / RN-E 70 FCQ-C / RKS-F 72 FCQ-C / RKS-F 73 FCQ-C7 / RXS-F 74 FCQ-C / RXS-F 75 FCQ-C / RN-E 76 FCQ-C / RR-B 77 FCQ-C / RQ-B 78 FCQ-C / REQ-B 79 FCQ-C / RZQS-B/C 80 FCQ-C / RZQ-B/C 81 FCQH-C / RZQS-B/C 82 FCQH-C / RZQ-B/C Way blow ceiling suspended cassettes FUQ-B / RR-B 84 FUQ-B / RQ-B 85 FUQ-B / RZQ-B/C Ceiling suspended units FHQ-B / RKS-E 88 FHQ-B / RKS-F 89 FHQ-B / RXS-E 90 FHQ-B / RXS-F 91 FHQ-B / RN-E 92 FHQ-B / RR-B 93 FHQ-B / RQ-B 94 FHQ-B / REQ-B 95 FHQ-B / RZQS-B/C 96 FHQ-B / RZQ-B/C 97 TWIN/TRIPLE/DOUBLE TWIN APPLICATIONS Possible combinations 99 RZQS 100 RZQ 102 RR 104 RQ 106 RP 108 RYP 109 MULTI MODEL APPLICATION MKS-E/F 110 MXS-E/F 113 RMXS-E 117 ALTHERMA 121 AIR HANDLING UNIT CONNECTIONS ERX 125 VRV Air handling applications 127 ROOFTOP UNITS UATP-A 128 UATYP-A 129

14 Good Design Award 1. URURU HUMIDIFICATION: All the moisture in the outdoor air available inside The Ururu humidification subsystem uses a special built-in humidification element in the outdoor unit to absorb the moisture present in the outdoor air and send it to the indoor unit. Since moisture is not absorbed from the room s air, quick and effective humidification is possible even with the drier air of winter. Humidification unit Moisture particles Moisture is extract ed from the outdoor air Fully humidified air is delivered to the room. Ururu humidification evenly heats the entire room. The unit incor porates both an air conditioner and a humidifier, making ideal heating pos sible. The Ururu humidification subsystem effectively supplies the 450ml/h of water required to fully humidify an entire large living room. Humidified air feels warmer Dry air actually makes your body feel cooler. Ururu humidification at moderate levels and a relatively low temperature will probabely leave you feeling warmer. This also prevents dry skin and sore throats, and maintains a humidity level in which viruses cannot survive. Room temperature 28 C Humidity 20% Ururu humidification operation COLD You feel cold in dry air even at high temperature. Room temperature 22 C Humidity 50% WARM You feel comfortable warmer in humidified air. 2. SARARA DEHUMIDIFICATION: Ururu Sarara reduces indoor humidity without affecting the room temperature, by mixing dry cool air with warm air to produce comfortable dry air (Sarara Drying Operation, also called reheating dehumidification). This feature prevents overcooling, which is particularly appreciated by people who are sensitive to cold. If the indoor temperature becomes too high, Ururu Sarara reduces humidity level by reducing also temperature (cooling dehumidification). Lower humidity creates comfortable dryness, even at a constant temperature Decreasing the level of humidity will increase your feeling of comfort, even while maintaining the same room temperature. This feature prevents overcooling, which is especially good for people who are sensitive to cold. Room temperature 25 C Humidity 80% Sarara dehumidification operation OVERHEATED COMFORTABLE DRY Hot and stuffy with high Decreasing humidity while humidity. maintaining the tempe rature increases comfort. 3. OTHER FEATURES: Room temperature 25 C Humidity 50% Powerful ventailation Powerful air purification with Daikin flash streamer technology Energy efficient: A class energy label Comfortable air flow Moisturizing operation mode Breeze cooling air flow Comfort sleep operation Mould shock operation Note: Humidification and dehumidification operations can be used under specific indoor and outdoor temperature and humidity conditions (similar to cooling and heating operation range). Please refer to the technical databooks for more details. 12

15 FTXR-E / RXR-E Wall mounted unit ARC 447AI FTXR 28,42,50E RXR 28,42,50E URURU humidifi cation: maintains a comfortable humidity level without any separate water supply SARARA dehumidifi cation: maintains a comfortable and fresh indoor environment by removing moisture from the air without lowering the temperature Energy effi cient: full range A class labels (EER = 5.00/COP = 5.14) Powerful ventilation: refreshes the room within 2 hours Powerful air purifi cation: increases indoor air quality with Daikin Flash Streamer technology Comfortable air fl ow Stylish design Other features: moisturizing operation mode, breeze cooling air fl ow, comfort sleep operation, mould shock operation (5 steps) (standard) (integrated titanium apatite) () Indoor Units FTXR28EV1B9 FTXR42EV1B9 FTXR50EV1B9 Nominal Capacity Cooling capacity Minimum kw 1.55 Standard kw Maximum kw Heating capacity Minimum kw 1.30 Standard kw Maximum kw Annual energy consumption kwh EER / COP Cooling / Heating 5.00 / / / 3.97 Energy Label cooling / heating A / A Dimensions (Height x Width x Depth) mm 209x890x305 Weight kg 14 Air Flow Rate Cooling H/M/L/SL m³/min 11.1 / 8.8 / 6.5 / / 9.6 / 6.8 / / 10.3 / 7.3 / 6.5 Heating H/M/L/SL m³/min 12.4 / 9.8 / 7.3 / / 10.2 / 7.7 / / 11.1 / 8.3 / 7.3 Sound Power Cooling Medium dba Heating Medium dba Sound Pressure Cooling H/M/L/SL dba 39 / 33 / 26 / / 35 / 27 / / 37 / 29 / 26 Heating H/M/L/SL dba 41 / 35 / 28 / / 36 / 29 / / 38 / 31 / 28 1~/ V/50Hz Outdoor Unit RXR28EV1B9 RXR42EV1B9 RXR50EV1B9 Dimensions (Height x Width x Depth) mm 693x795x285 Weight kg 48 Sound pressure level Cooling H/L dba Heating H/L dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~43 Heating Min~Max CWB -20~18 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 10 13

16 1. STYLISH AND COMPACT DESIGN Daikin succeeded in creating an indoor unit with such a sleek profile, that you won t believe it is an air conditioning unit. In standby mode, the discharge opening is closed, resulting in a compact depth of only 15cm. When starting the unit up, the entire front panel slides smoothly open. For this model, Daikin even received the Good Design Award in Japan. Good Design Award EER/COP Conventional 40% UP 4.03 NEW Cooling Conventional 40% UP 4.15 These top of the class values are achieved by the following 3 technologies: PAM Inverter control Reluctance DC motor + DC Fan motor Swing compressor 4. CLEAN AND COMFORTABLE AIR FLOW NEW Heating FTXG25 FTYN25 downward vertically to send the warm air directly to the feet. 3-D Air flow: This function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm air right to the corners of even large spaces. 2. SENSATIONAL THINNING TECHNOLOGY FTK(X)S 25% size reduction High efficiency slit fin heat exchanger: Miniature cross flow fan FTXG The blade configuration has been optimized to achieve quiet operation and powerful air flow, while reducing the fan s diameter by 20% compared to conventional models. 3. SUPERB ENERGY EFFICIENCY Daikin has further improved the energy efficiency. At the same time it realized substantial energy savings compared to conventional models by achieving an industrial top class EER of 4.03 and COP of For the fist time in history, a titanium apatite photocatalytic air purification filter is integrated in an air conitioning unit. This to increase the active surface area for effective purification and deodorisation, even when a high volume of air is required. Super quiet: The indoor/outdoor unit silent operation function brings us comfort by offering an industry top-level quiet operation of 22dB(A) for the indoor unit and 43dB(A) for the outdoor unit. Comfort mode: The new wide-angle distribution flap reassures draught free operation. During cooling operation the flap angle turns horizontally to prevent cold air blowing directly on the body, while during heating operation it turns Cooling mode Heating mode 14

17 FTXG-E / RXG-E Wall mounted unit ARC 433A41 FTXG 25,35E-S FTXG 25,35E-W RXG25,35E State of the art design: sleek, compact and stylish outlook Available in 2 colour variations: mat crystal white and mat crystal silver Lightweight and compact Easy to clean fl at suction grille Superb energy effi ciency Movement sensor saves power consumption in unoccupied rooms Comfort mode reassures draught free operation thanks to the new wide angle distribution fl ap The new titanium apatite photocatalytic air purifi cation fi lter increases the active surface area for effective purifi cation and deodorisation Horizontal and vertical auto-swing 3D-air fl ow ensure effi cient air and temperature distribution. Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation (5 steps) (standard) (integrated titanium apatite) MXS () Indoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BS Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw Annual energy consumption kwh EER / COP Cooling / Heating 4.03 / / 3.72 Energy Label cooling / heating A / A Dimensions (Height x Width x Depth) mm 275x840x150 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 7.7 / 6.1 / 4.7 / / 6.5 / 4.9 / 4.1 Heating H/M/L/SL m³/min 9.0 / 7.9 / 6.7 / / 8.2 / 6.7 / 5.9 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 32.0 / 25.0 / / 33.0 / 26.0 / 23.0 Heating H/M/L/SL dba 38.0 / 33.0 / 28.0 / / 34.0 / 29.0 / ~/ V/50Hz Outdoor Unit RXG25E2V1B RXG35E2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 32 Sound pressure level Cooling H dba Heating H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB 10.0~46.0 Heating Min~Max CWB -15.0~ ~20 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 20 Max. internunit level difference m

18 FTKS-DW / RKS-E Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC433A43 FTKS20,25,35D3VMW RKS20,25,35E 5 steps standard MKS (integrated titanium apatite) COOLING ONLY Indoor Units FTKS20D3VMW FTKS25D3VMW FTKS35D3VMW Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling A A A Dimensions (Height x Width x Depth) mm 283x800x x800x x800x195 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.7 / 4.7 / / 6.9 / 4.8 / 4.0 Sound Power Cooling High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 25.0 / / 26.0 / 23.0 H/M/L/SL dba R-410A R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RKS20E2V1B RKS25E2V1B RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x x765x285 Weight kg Sound pressure level H / L dba 46 / / / 44 Sound power level H dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

19 FTKS-DW / RKS-F Wall mounted unit ARC433A43 FTKS50D2V1W RKS50F Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) 5 steps standard MKS (integrated titanium apatite) COOLING ONLY Indoor Units FTKS50D2V1W Nominal Capacity Cooling capacity Minimum kw 1.7 Standard kw 5.0 Maximum kw 5.2 EER Nominal 3.03 Annual energy consumption kwh 825 Energy Label cooling B Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 11.4 / 9.3 / 7.1 / 6.2 Sound Power Cooling High dba 62.0 Sound Pressure Cooling H/M/L/SL dba 46.0 / 41.0 / 35.0 / ~/ V/50Hz Outdoor Unit RKS50F2V1B Dimensions (Height x Width x Depth) mm 735x825x300 Weight kg 48 Sound pressure level H / SL dba 47 / 44 Sound power level H dba 61 Operation Range Cooling Min~Max CDB -10~ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 20 Piping Length (Maximum) m 30 Max. internunit level difference m 20 17

20 FTXS-DW / RXS-E Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than noninverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution ARC433A43 FTXS20,25,35D3VMW RXS20,25,35E Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation Night quiet mode (only in multi application standard and cooling only mode) MXS 5 steps (integrated titanium apatite) Indoor Units FTXS20D3VMW FTXS25D3VMW FTXS35D3VMW Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 4.17 / / / 3.70 Annual energy consumption kwh Energy Label cooling / heating A / A A / A A / A Dimensions (Height x Width x Depth) mm 283x800x x800x x800x195 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.7 / 4.7 / / 6.9 / 4.8 / 4.0 Heating H/M/L/SL m³/min 9.4 / 7.6 / 5.8 / / 7.6 / 5.8 / / 7.9 / 6.0 / 5.2 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 25.0 / / 26.0 / 23.0 H/M/L/SL dba Heating H/L/SL dba 38.0 / 28.0 / / 28.0 / / 29.0 / 26.0 H/M/L/S dba R-410A R-410A 1~/ / V/50/60Hz 1~ / V/50/60Hz 1~ / V/50/60Hz Outdoor Unit RXS20E2V1B RXS25E2V1B RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x x765x285 Weight kg Sound pressure level Cooling H/L dba 46 / / / 44 Heating H/L dba 47 / / / 45 Sound power level Cooling dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 Heating Min~Max CWB -15~20-15~20-15~20 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

21 FTXS-DW / RXS-F Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution ARC433A43 Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) FTXS50D2V1W MXS RXS50F 5 steps standard (integrated titanium apatite) Indoor Units FTXS50D2V1W Nominal Capacity Cooling capacity Minimum kw 1.7 Standard kw 5.0 Maximum kw 5.2 Heating capacity Minimum kw 1.7 Standard kw 5.8 Maximum kw 6.0 EER / COP Cooling / Heating 3.03 / 2.82 Annual energy consumption kwh 825 Energy Label cooling / heating B / D Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 11.4 / 9.3 / 7.1 / 6.2 Heating H/M/L/SL m³/min 11.4 / 9.4 / 7.4 / 6.3 Sound Power Cooling High dba 62.0 Heating High dba 62.0 Sound Pressure Cooling H/M/L/SL dba 46.0 / 41.0 / 35.0 / 32.0 Heating H/M/L/SL dba 46.0 / 40.0 / 34.0 / ~/ V/50Hz Outdoor Unit RXS50F2V1B Dimensions (Height x Width x Depth) mm 735x825x300 Weight kg 48 Sound pressure level Cooling H/SL dba 47 / 44 Heating H/L dba 48 / 45 Sound power level Cooling H dba 61 Operation Range Cooling Min~Max CDB -10~46 Heating Min~Max CWB -15~ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 20 Piping Length (Maximum) m 30 19

22 FTKS-DL / RKS-E Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC433A43 FTKS20,25,35D3VML RKS20,25,35E 5 steps standard MKS (integrated titanium apatite) COOLING ONLY Indoor Units FTKS20D3VML FTKS25D3VML FTKS35D3VML Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling A A A Dimensions (Height x Width x Depth) mm 283x800x x800x x800x195 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.7 / 4.7 / / 6.9 / 4.8 / 4.0 Sound Power Cooling High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 25.0 / / 26.0 / 23.0 H/M/L/SL dba R-410A R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RKS20E2V1B RKS25E2V1B RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x x765x285 Weight kg Sound pressure level H / L dba 46 / / / 44 Sound power level H dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

23 FTKS-DL / RKS-F Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC433A43 FTKS50D2V1L RKS50F 5 steps standard MKS (integrated titanium apatite) COOLING ONLY Indoor Units FTKS50D2V1L Nominal Capacity Cooling capacity Minimum kw 1.7 Standard kw 5.0 Maximum kw 5.2 EER Nominal 3.03 Annual energy consumption kwh 825 Energy Label cooling B Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 11.4 / 9.3 / 7.1 / 6.2 Sound Power Cooling High dba 62.0 Sound Pressure Cooling H/M/L/SL dba 46.0 / 41.0 / 35.0 / ~/ V/50Hz Outdoor Unit RKS50F2V1B Dimensions (Height x Width x Depth) mm 735x825x300 Weight kg 48 Sound pressure level H / SL dba 47 / 44 Sound power level H dba 61 Operation Range Cooling Min~Max CDB -10~ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 20 Piping Length (Maximum) m 30 Max. internunit level difference m 20 21

24 FTXS-DL / RXS-E Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than noninverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution ARC433A43 FTXS20,25,35D3VML RXS20,25,35E Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation Night quiet mode (only in multi application standard and cooling only mode) MXS 5 steps (integrated titanium apatite) Indoor Units FTXS20D3VML FTXS25D3VML FTXS35D3VML Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 4.17 / / / 3.70 Annual energy consumption kwh Energy Label cooling / heating A / A A / A A / A Dimensions (Height x Width x Depth) mm 283x800x x800x x800x195 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.7 / 4.7 / / 6.9 / 4.8 / 4.0 Heating H/M/L/SL m³/min 9.4 / 7.6 / 5.8 / / 7.6 / 5.8 / / 7.9 / 6.0 / 5.2 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 25.0 / / 26.0 / 23.0 H/M/L/SL dba Heating H/L/SL dba 38.0 / 28.0 / / 28.0 / / 29.0 / 26.0 H/M/L/S dba R-410A R-410A 1~/ / V/50/60Hz 1~ / V/50/60Hz 1~ / V/50/60Hz Outdoor Unit RXS20E2V1B RXS25E2V1B RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x x765x285 Weight kg Sound pressure level Cooling H/L dba 46 / / / 44 Heating H/L dba 47 / / / 45 Sound power level Cooling dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 Heating Min~Max CWB -15~20-15~20-15~20 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

25 FTXS-DL/ RXS-F Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units ECONO mode decreases power consumption so that other appliances that need large power supply can be used Energy saving Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution ARC433A43 Comfort mode reassures draught free operation Titanium apatite photocatalytic air purifi cation fi lter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) FTXS50D2V1L MXS RXS50F 5 steps standard (integrated titanium apatite) Indoor Units FTXS50D2V1L Nominal Capacity Cooling capacity Minimum kw 1.7 Standard kw 5.0 Maximum kw 5.2 Heating capacity Minimum kw 1.7 Standard kw 5.8 Maximum kw 6.0 EER / COP Cooling / Heating 3.03 / 2.82 Annual energy consumption kwh 825 Energy Label cooling / heating B / D Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 11.4 / 9.3 / 7.1 / 6.2 Heating H/M/L/SL m³/min 11.4 / 9.4 / 7.4 / 6.3 Sound Power Cooling High dba 62.0 Heating High dba 62.0 Sound Pressure Cooling H/M/L/SL dba 46.0 / 41.0 / 35.0 / 32.0 Heating H/M/L/SL dba 46.0 / 40.0 / 34.0 / ~/ V/50Hz Outdoor Unit RXS50F2V1B Dimensions (Height x Width x Depth) mm 735x825x300 Weight kg 48 Sound pressure level Cooling H/SL dba 47 / 44 Heating H/L dba 48 / 45 Sound power level Cooling H dba 61 Operation Range Cooling Min~Max CDB -10~46 Heating Min~Max CWB -15~18 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 18 Piping Length (Maximum) m 30 Max. internunit level difference m 15 23

26 FTKS-C / RK-E Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Air purifi cation fi lter with photocatalytic deodorising function Powerful mode can be selected for rapid cooling Indoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC433A2 FTKS20,25,35C RK 20,25,35E (5 steps) (standard) MKS () COOLING ONLY Indoor Units FTKS20CAVMB FTKS25CAVMB FTKS35CAVMB Condition 2 Cooling capacity Minimum kw kw Maximum kw EER Nominal Annual energy consumption kwh Energy label A A A Dimensions (Height x Width x Depth) mm 273x784x195 Weight kg 7.5 Air Flow Rate Cooling H/M/L/SL m³/min 7.70 / 5.90 / 4.20 / / 6.00 / 4.40 / 3.80 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 32.0 / 25.0 / / 33.0 / 26.0 / ~/ / V/50/60Hz Outdoor Unit RK20E2V1B RK25E2V1B RK35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound power level H dba Sound pressure level H dba Operation Range Cooling Min~Max CDB 10.0~46.0 1~/ / V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 15 Max. internunit level difference m

27 FTXS-C / RX-E Wall mounted unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units Reaches set temperature more quickly Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Air purifi cation fi lter with photocatalytic deodorising function Powerful mode can be selected for rapid cooling or heating Indoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC 433AR FTXS 20,25,35C RX 20,25,35E (5 steps) (standard) MXS () Indoor Units FTXS20CAVMB FTXS25CAVMB FTXS35CAVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw Annual energy consumption kwh EER / COP Cooling / Heating 3.45 / / / 3.63 Energy Label cooling / heating A / A A / A A / A Dimensions (Height x Width x Depth) mm 273x784x195 Weight kg 7.5 Air Flow Rate Cooling H/M/L/SL m³/min 7.70 / 5.90 / 4.20 / / 6.00 / 4.40 / 3.80 Heating H/M/L/SL m³/min 7.80 / 6.50 / 5.30 / / 6.70 / 5.30 / 4.60 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 32.0 / 25.0 / / 33.0 / 26.0 / 23.0 Heating H/M/L/SL dba 38.0 / 33.0 / 28.0 / / 34.0 / 29.0 / ~/ / V/50/60Hz Outdoor Unit RX20E2V1B RX25E2V1B RX35E2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg Sound pressure level Cooling H dba Heating H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB 10.0~46.0 Heating Min~Max CWB -10~20 1~/ / V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 15 Max. internunit level difference m

28 FTKS-F / RKS-F Wall mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Titanium apatite photocatalytic air purifi cation fi lter Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC433A70 FTKS50,60,71F 5 steps RKS50,60,71F standard MKS (integrated titanium apatite) COOLING ONLY Indoor Units FTKS50FV1B FTKS60FV1B FTKS71FV1B Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling A B B Dimensions (Height x Width x Depth) mm 290x1050x x1050x x1050x238 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 14.7 / 12.4 / 10.3 / / 13.6 / 11.4 / / 14.6 / 11.6 / 10.6 Sound Power Cooling Medium dba Sound Pressure Cooling H/M/L/SL dba 43 / 39 / 34 / / 41 / 36 / / 42 / 37 / 34 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RKS50F2V1B RKS60F2V1B RKS71FV1B Dimensions (Height x Width x Depth) mm 735x825x x825x x900x320 Weight kg Sound pressure level H/SL dba 47 / / / 49 Sound power level H dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / / 15.9 / 18 Piping Length (Maximum) m Max. internunit level difference m

29 FTXS-F / RXS-F Wall Mounted Unit ARC433A70 FTXS50,60,71F RXS50,60,71F Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Lightweight and compact Home leave operation saves energy during absence Movement sensor saves power consumption in unoccupied rooms Dual air discharge fl ow for better air distribution Titanium apatite photocatalytic air purifi cation fi lter Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) 5 steps standard MXS (integrated titanium apatite) Indoor Units FTXS50FV1B FTXS60FV1B FTXS71FV1BA Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 3.23 / / / 3.22 Annual energy consumption kwh Energy Label cooling / heating A / A B / B B / C Dimensions (Height x Width x Depth) mm 290x1050x x1050x x1050x238 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 14.7 / 12.4 / 10.3 / / 13.6 / 11.4 / / 14.6 / 11.6 / 10.6 Heating H/M/L/SL m³/min 16.1 / 13.9 / 11.5 / / 15.1 / 12.7 / / 16.9 / 14.3 / 12.7 Sound Power Cooling Medium dba Heating Medium dba Sound Pressure Cooling H/M/L/SL dba 43 / 39 / 34 / / 41 / 36 / / 42 / 37 / 34 Heating H/M/L/SL dba 42 / 38 / 33 / / 40 / 35 / / 42 / 37 / 34 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RXS50F2V1B RXS60F2V1B RXS71FV1B Dimensions (Height x Width x Depth) mm 735x825x x825x x900x320 Weight kg Sound pressure level Cooling H/SL dba 47 / / Heating H/SL dba 48 / / Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 Heating Min~Max CWB -15~18-15~18-15~18 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / / 15.9 / 18 Piping Length (Maximum) m Max. internunit level difference m

30 FAQ-B / RR-B Wall Mounted Unit FAQ71,100B Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off Automatic movable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit BRC1D52 BRC7E619/C511 heat pump RR100B 2 steps COOLING ONLY NON- Indoor Units FAQ71BVV1B FAQ100BVV1B Capacity Cooling capacity Standard kw EER Nominal Energy Label Cooling D C C C Annual energy consumption kwh Dimensions (Height x Width x Depth) mm 290x1050x x1570x200 Weight kg Air Flow Rate Cooling High/Low m³/min 19.0 / / 19.0 Sound Power Cooling High/Low dba 59.0 / / 57.0 Heating High/Low dba 59.0 / / 57.0 Sound Pressure Cooling High/Low dba 43.0 / / ~/230V/50Hz Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Operation Range Cooling Min~Max CDB -15.0~46.0 Sound Level (nominal) Sound Power Cooling dba Sound Pressure Cooling dba ~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 32

31 FAQ-B / RQ-B Wall Mounted Unit FAQ71,100B Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off Automatic movable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit BRC1D52 BRC7E618/C510 heat pump RQ100B 2 steps NON- Indoor Units FAQ71BVV1B FAQ100BVV1B Capacity Cooling capacity Standard kw Heating capacity Standard kw Annual energy consumption kwh EER / COP Cooling / Heating 2.68 / / / / 2.93 Energy Label cooling / heating D / D C / C C / D Dimensions (Height x Width x Depth) mm 290x1050x x1570x200 Weight kg Air Flow Rate Cooling High/Low m³/min 19.0 / / 19.0 Heating High/Low m³/min 19.0 / / 19.0 Sound Power Cooling High/Low dba 59.0 / / 57.0 Heating High/Low dba 59.0 / / 57.0 Sound Pressure Cooling High/Low dba 43.0 / / 41.0 Heating High/Low dba 43.0 / / ~/230V/50Hz Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 Sound Level (nominal) Sound Power Cooling dba Sound Pressure Cooling dba ~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 33

32 FAQ-B / RZQS-B Wall Mounted Unit BRC1D52 BRC7E618/C510 FAQ71,100B RZQS71,100B Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off Automatic movable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit heat pump 2 steps Indoor Units FAQ71BVV1B FAQ100BVV1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.81 / / 3.00 Annual energy consumption kwh Energy Label cooling / heating C / D E / D Dimensions (Height x Width x Depth) mm 290x1050x x1570x200 Weight kg Air Flow Rate Cooling High/Low m³/min 19.0 / / 19.0 Heating High/Low m³/min 19.0 / / 19.0 Sound Power Cooling High/Low dba 59.0 / / 57.0 Heating High/Low dba 59.0 / / 57.0 Sound Pressure Cooling High/Low dba 43.0 / / 41.0 Heating High/Low dba 43.0 / / 41.0 R-410A 1~/230V/50Hz 1~/230V/50Hz Outdoor Unit RZQS71B7V3B RZQS100B7V3B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Operation Range Cooling Min~Max CDB -5.0~ ~46.0 Heating Min~Max CWB -15.0~ ~15.5 Sound pressure level Cooling (night quiet mode) dba 49 (43) 51 (45) Heating dba Sound power level Cooling dba R-410A 1~/230V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

33 FAQ-B / RZQ-B/C Wall Mounted Unit Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off Automatic movable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit BRC1D52 BRC7E618/C510 FAQ71,100B heat pump RZQ100B 2 steps Indoor Units FAQ71BVV1B FAQ100BVV1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 3.01 / / / 3.30 Annual energy consumption kwh Energy Label cooling / heating B / C C / B A / C Dimensions (Height x Width x Depth) mm 290x1050x x1570x200 Weight kg Air Flow Rate Cooling High/Low m³/min 19.0 / / 19.0 Heating High/Low m³/min 19.0 / / 19.0 Sound Power Cooling High/Low dba 59.0 / / 57.0 Heating High/Low dba 59.0 / / 57.0 Sound Pressure Cooling High/Low dba 43.0 / / 41.0 Heating High/Low dba 43.0 / / 41.0 R-410A 1~/230V/50Hz 1~/230V/50Hz Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~15.5 R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

34 FLKS-B / RKS-E Flexi Type Unit ARC433A6 FLKS25,35B FLKS25,35B RKS25,35E Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consumes up to 30% less energy than non-inverter units Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and temperature distribution. Home leave operation saves energy during absence Air purifi cation and photocatalytic deodorising fi lter Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) 5 steps standard MKS COOLING ONLY Indoor Units FLKS25BAVMB FLKS35BAVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling A B Dimensions (Height x Width x Depth) mm 490x1050x x1050x200 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 7.60 / 6.80 / 6.00 / / 7.60 / 6.6 / 5.6 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 34.0 / 31.0 / / 35.0 / 32.0 / 29.0 R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RKS25E2V1B RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound pressure level H/L dba 46 / / 44 Sound power level H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

35 FLKS-B / RKS-F Flexi type unit ARC433A6 FLKS50B FLKS50B RKS50F Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consumes up to 30% less energy than non-inverter units Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and temperature distribution. Home leave operation saves energy during absence Air purifi cation and photocatalytic deodorising fi lter Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) 5 steps standard MKS COOLING ONLY Indoor Units FLKS50BAVMB Nominal Capacity Cooling capacity Minimum kw 1.7 Standard kw 4.9 Maximum kw 5.3 EER Nominal 2.85 Annual energy consumption kwh 860 Energy Label cooling C Dimensions (Height x Width x Depth) mm 490x1050x200 Weight kg 17.0 Air Flow Rate Cooling H/M/L/SL m³/min / / 8.50 / 7.5 Sound Power Cooling High dba 63.0 Sound Pressure Cooling H/M/L/SL dba 47.0 / 43.0 / 39.0 / ~/ / V/50/60Hz Outdoor Unit RKS50F2V1B Dimensions (Height x Width x Depth) mm 735x825x300 Weight kg 48 Sound pressure level H/L dba 47 / 44 Sound power level H dba 61 Operation Range Cooling Min~Max CDB -10~46 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 20 Piping Length (Maximum) m 30 Max. internunit level difference m 20 37

36 39 _

37 FLXS-B / RXS-E Flexi type unit ARC 433A6 Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consumes up to 30% less energy than noninverter units Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and temperature distribution. Home leave operation saves energy during absence Air purifi cation and photocatalytic deodorising fi lter Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) FLXS 25,35B FLXS 25,35B RXS 25,35E 5 steps standard MXS Indoor Units FLXS25BAVMB FLXS35BAVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw Annual energy consumption kwh EER / COP Cooling / Heating 3.85 / / 3.25 Energy Label cooling / heating A / B B / C Dimensions (Height x Width x Depth) mm 490x1050x x1050x200 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 7.60 / 6.80 / 6.00 / / 7.60 / 6.60 / 5.6 Heating H/M/L/SL m³/min 9.20 / 8.30 / 7.40 / / 8.90 / 8.00 / 7.2 Sound Power Cooling High dba Heating High dba - - Sound Pressure Cooling H/M/L/SL dba 37.0 / 34.0 / 31.0 / / 35.0 / 32.0 / 29.0 Heating H/M/L/SL dba 37.0 / 34.0 / 31.0 / / 36.0 / 33.0 / 30.0 R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RXS25E2V1B RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound pressure level Cooling H/L dba 46 / / 44 Heating H/L dba 47 / / 45 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~20-15~20 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

38 FLXS-B / RXS-F Flexi type unit Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consumes up to 30% less energy than noninverter units Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and temperature distribution. Home leave operation saves energy during absence Air purifi cation and photocatalytic deodorising fi lter Powerful mode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation Night quiet mode (only in multi application and cooling only mode) ARC433A6 FLXS50B FLXS50B 5 steps standard RXS50F MXS Indoor Units FLXS50BAVMB Nominal Capacity Cooling capacity Minimum kw 1.7 Standard kw 4.9 Maximum kw 5.3 Heating capacity Minimum kw 1.7 Standard kw 6.1 Maximum kw 7.5 EER / COP Cooling / Heating 2.85 / 3.35 Annual energy consumption kwh 860 Energy Label cooling / heating C / C Dimensions (Height x Width x Depth) mm 490x1050x200 Weight kg 17.0 Air Flow Rate Cooling H/M/L/SL m³/min / / 8.50 / 7.6 Heating H/M/L/SL m³/min 12.1 / 9.8 / 7.5 / 6.8 Sound Power Cooling High dba 63.0 Heating High dba 62.0 Sound Pressure Cooling H/M/L/SL dba 47.0 / 43.0 / 39.0 / 36.0 Heating H/M/L/SL dba 46.0 / 41.0 / 35.0 / ~/ / V/50/60Hz Outdoor Unit RXS50F2V1B Dimensions (Height x Width x Depth) mm 735x825x300 Weight kg 48 Sound pressure level Cooling H/SL dba 47 / 44 Heating H/SL dba 48 / 45 Sound power level Cooling H dba 61 Operation Range Cooling Min~Max CDB -10~46 Heating Min~Max CWB -15~18 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 20 Piping Length (Maximum) m 30 Max. internunit level difference m 20 41

39 FVXS-F / RKS-F Floor Standing Unit ARC452AI FVXS25,35,50F RKS25,35F Stylish design Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Titanium apatite photocatalytic air purifi cation fi lter Can be installed against a wall or recessed Dual air discharge fl ow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Lightweight but sturdy design 5 steps standard Titanium apatite photocatalytic air purifi cation fi lter COOLING ONLY Indoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling A A A Dimensions (Height x Width x Depth) mm 600x700x x700x x700x210 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.2 / 6.5 / 4.8 / / 6.7 / 4.9 / / 9.2 / 7.8 / 6.6 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 38 / 32 / 26 / / 33 / 27 / / 40 / 36 / 32 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RKS25F2V1B RKS35F2V1B RKS50F2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x x825x300 Weight kg Sound pressure level Cooling H/L dba 46 / / / 44 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 R-410A R-410A 1~/ V/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / / 12.7 / 20 Piping Length (Maximum) m Max. internunit level difference m

40 FVXS-F / RXS-F Floor standing unit Stylish design Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Titanium apatite photocatalytic air purifi cation fi lter Can be installed against a wall or recessed Dual air discharge fl ow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Lightweight but sturdy design ARC452A1 FVXS 25,35,50F RXS 25,35 F 5 steps standard Titanium apatite photocatalytic air purifi cation fi lter Indoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 4.39 / / / 3.63 Annual energy consumption kwh Energy Label cooling / heating A / A A / A A / A Dimensions (Height x Width x Depth) mm 600x700x x700x x700x210 Weight kg Air Flow Rate Cooling H/M/L/SO m³/min 8.2 / 6.5 / 4.8 / / 6.7 / 4.9 / / 9.2 / 7.8 / 6.6 Heating H/M/L/SO m³/min 8.8 / 6.9 / 5.0 / / 7.3 / 5.2 / / 10.1 / 8.5 / 7.1 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SO dba 38 / 32 / 26 / / 33 / 27 / / 40 / 36 / 32 Heating H/M/L/SO dba 38 / 32 / 26 / / 33 / 27 / / 40 / 36 / 32 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RXS25F2V1B RXS35F2V1B RXS50F2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x x825x300 Weight kg Sound pressure level Cooling H/L dba 46 / / / 44 Heating H/L dba 47 / / / 45 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46-10~46 Heating Min~Max CWB -15~20-15~20-15~18 R-410A R-410A 1~/ V/ V/50Hz 1~/ V/ V/50Hz 1~/ V/50Hz Piping Connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / / 12.7 / 20 Piping Length (Maximum) m Max. internunit level difference m

41 FDKS-E / RKS-E Slim concealed ceiling unit Slim design for fl exible installation Compact dimensions, can easily be mounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling or heating Home leave operation saves energy during absence Standard suction fi lter: removes airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Night quiet mode (only in multi application and cooling only mode) Medium external static pressure facilitates unit use with fl exible ducts of varying lengths ARC433A8 FDKS25,35E RKS25,35E standard MKS 5 steps COOLING ONLY Indoor Units FDKS25EAVMB FDKS35EAVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Energy label A B Annual energy consumption kwh Dimensions (Height x Width x Depth) mm 200x700x x700x620 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 8.0 / 7.3 / / 8.0 / 7.3 / 6.2 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 35.0 / 33.0 / 31.0 / / 33.0 / 31.0 / 29.0 R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RKS25E2V1B RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound pressure level Cooling H/L dba 46 / / 44 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

42 FDKS-C / RKS-F Slim Concealed Ceiling Unit ARC433A8 FDKS50,60C RKS50,60F Slim design for fl exible installation Compact dimensions, can easily be mounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling or heating Home leave operation saves energy during absence Standard suction fi lter: removes airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Night quiet mode (only in multi application and cooling only mode) Medium external static pressure facilitates unit use with fl exible ducts of varying lengths standard MKS 5 steps COOLING ONLY Indoor Units FDKS50CVMB FDKS60CVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling B C Dimensions (Height x Width x Depth) mm 200x900x x1100x620 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 12.0 / 11.0 / 10.0 / / 14.8 / 13.5 / 11.2 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 35.0 / 33.0 / / 36.0 / 34.0 / 32.0 R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RKS50F2V1B RKS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/SL dba 47 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

43 FDXS-E / RXS-E Slim concealed ceiling unit Slim design for fl exible installation Compact dimensions, can easily be mounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling or heating Home leave operation saves energy during absence Standard suction fi lter: removes airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Night quiet mode (only in multi application and cooling only mode) Medium external static pressure facilitates unit use with fl exible ducts of varying lengths ARC433A8 FDXS25,35E RXS25,35E standard MXS 5 steps Indoor Units FDXS25EAVMB FDXS35EAVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw Annual energy consumption kwh EER / COP Cooling / Heating 3.48 / / 3.39 Energy Label cooling / heating A / B B / C Dimensions (Height x Width x Depth) mm 200x700x x700x620 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 8.0 / 7.3 / / 8.0 / 7.3 / 6.2 Heating H/M/L/SL m³/min 8.7 / 8.0 / 7.3 / / 8.0 / 7.3 / 6.2 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 35.0 / 33.0 / 31.0 / / 33.0 / 31.0 / 29.0 Heating H/M/L/SL dba 35.0 / 33.0 / 31.0 / / 33.0 / 31.0 / 29.0 R-410A 1~/ / V/50/60Hz 1~/ / V/50/60Hz Outdoor Unit RXS25E2V1B RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound pressure level Cooling H/L dba 46 / / 44 Heating H/L dba 47 / / 45 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~20-15~20 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

44 FDXS-C / RXS-F Slim Concealed Ceiling Unit ARC433A8 FDXS 50,60C RXS50,60F Slim design for fl exible installation Compact dimensions, can easily be mounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling or heating Home leave operation saves energy during absence Standard suction fi lter: removes airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Night quiet mode (only in multi application and cooling only mode) Medium external static pressure facilitates unit use with fl exible ducts of varying lengths standard MXS 5 steps Indoor Units FDXS50CVMB FDXS60CVMB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 3.03 / / 3.02 Annual energy consumption kwh Energy Label cooling / heating B / D C / D Dimensions (Height x Width x Depth) mm 200x900x x1100x620 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 12.0 / 11.0 / 10.0 / / 14.8 / 13.5 / 11.2 Heating H/M/L/SL m³/min 12.0 / 11.0 / 10.0 / / 14.8 / 13.5 / 11.2 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 35.0 / 33.0 / / 36.0 / 34.0 / 32.0 Heating H/M/L/SL dba 37.0 / 35.0 / 33.0 / / 36.0 / 34.0 / 32.0 R-410A / V/50/60Hz / V/50/60Hz Outdoor Unit RXS50F2V1B RXS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/SL dba 47 / / 46 Heating H/SL dba 48 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~18-15~18 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

45 FBQ-B / RKS-E Concealed ceiling unit Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa BRC1D52 FBQ35,50B RKS35E heat pump standard 2 steps 35~60 COOLING ONLY Indoor Units FBQ35B8V1 Nominal Capacity Cooling capacity Standard kw 3.4 EER Nominal 2.91 Energy label Cooling C Annual energy consumption kwh 585 Dimensions (Height x Width x Depth) mm 300x700x800 Weight kg 30 Air Flow Rate Cooling High/Low m³/min 11.5 / 9 Sound Power Cooling High dba 52 Sound Pressure Cooling High/Low dba 33 / 29 1~/230V/50Hz Decoration Panel Model BYBS45D Colour White HxWxD mm 55x800x500 Weight kg 3.5 Outdoor Unit RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 32 Sound pressure level Cooling H/L dba 47 / 44 Sound power level Cooling H dba 62 Operation Range Cooling Min~Max CDB -10~46 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 20 Max. internunit level difference m 15 48

46 FBQ-B / RKS-F Concealed ceiling unit Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa BRC1D52 FBQ60B RKS50,60F heat pump standard 2 steps 35~60 COOLING ONLY Indoor Units FBQ50B8V1 FBQ60B8V1 Nominal Capacity Cooling capacity Standard kw EER Nominal Annual energy consumption kwh Energy Label Cooling E E Dimensions (Height x Width x Depth) mm 300x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min 14 / / 14 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 33 / / 30 R-410A 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYBS45D BYBS71D Colour White White HxWxD mm 55x800x500 55x1100x500 Weight kg Outdoor Unit RKS50F2V1B RKS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

47 FBQ-B / RXS-E Concealed ceiling unit Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa BRC1D52 FBQ35,50B RXS35E heat pump standard 2 steps 35~60 Indoor Units FBQ35B8V1 Nominal Capacity Cooling capacity Standard kw 3.4 Heating capacity Standard kw 4.0 Annual energy consumption kwh 585 EER / COP Cooling / Heating 2.91 / 3.28 Energy Label cooling / heating C / C Dimensions (Height x Width x Depth) mm 300x700x800 Weight kg 30 Air Flow Rate Cooling High/Low m³/min 11.5 / 9 Heating High/Low m³/min 11.5 / 9 Sound Power Cooling High dba 52 Heating High dba 52 Sound Pressure Cooling High/Low dba 33 / 29 Heating High/Low dba 33 / 29 1~/230V/50Hz Decoration Panel Model BYBS45D Colour White HxWxD mm 55x800x500 Weight kg 3.5 Outdoor Unit RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 32 Sound pressure level Cooling H/L dba 47 / 44 Heating H/L dba 48 / 45 Sound power level Cooling H dba 62 Operation Range Cooling Min~Max CDB -10~46 Heating Min~Max CWB -15~20 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 20 Max. inernunit level difference m 15 50

48 FBQ-B / RXS-F Concealed ceiling unit BRC1D52 FBQ60B RXS50,60F Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa standard 2 steps heat pump 35~60 Indoor Units FBQ50B8V1 FBQ60B8V1 Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.60 / / 2.80 Annual energy consumption kwh Energy Label cooling / heating E / C E / E Dimensions (Height x Width x Depth) mm 300x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min 14 / / 14 Heating High/Low m³/min 14 / / 14 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Low dba 33 / / 30 Heating High/Low dba 33 / / 30 R-410A 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYBS45D BYBS71D Colour White White HxWxD mm 55x800x500 55x1100x500 Weight kg Outdoor Unit RXS50F2V1B RXS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/SL dba 47 / / 46 Heating H/SL dba 48 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~18-15~18 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

49 FBQ-B / RR-B Concealed ceiling unit Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa BRC1D52 FBQ100,125B RR71B heat pump standard 2 steps COOLING ONLY NON- Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B Nominal Capacity Cooling capacity Standard kw EER Nominal Energy Label Cooling E D D D D Annual energy consumption kwh Dimensions (Height x Width x Depth) mm 300x1000x x1400x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / / Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / ~/230V/50Hz Decoration Panel Model BYBS71DJW1 BYBS125DJW1 Colour White HxWxD mm 55x1100x500 55x1500x500 Weight kg Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -15.0~46.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 53

50 FBQ-B / RQ-B Concealed Ceiling Unit Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa BRC1D52 FBQ100, 125B standard 2 steps heat pump RQ100B NON- Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw Annual energy consumption kwh EER / COP Cooling / Heating 2.54 / / / / / 3.21 Energy Label Cooling / Heating E / C D / C D / D D / D D / C Dimensions (Height x Width x Depth) mm 300x1000x x1400x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / / Heating High/Low m³/min 19.00/ / / Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / 32.0 Heating High/Low dba 34.0 / / / ~/230V/50Hz Decoration Panel Model BYBS71DJW1 BYBS125DJW1 Colour White HxWxD mm 55x1100x500 55x1500x500 Weight kg Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 54

51 FBQ-B / RZQS-B/C Concealed ceiling unit BRC1D52 FBQ 100,125,140B RZQS 125,140C Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa heat pump standard 2 steps Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.82 / / / / 3.21 Annual energy consumption kwh Energy Label cooling / heating C / C D / C C / C C / C Dimensions (Height x Width x Depth) mm 300x1000x x1400x x1400x x1400x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / / / Heating High/Low m³/min / / / / Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / / 32.0 Heating High/Low dba 34.0 / / / / 32.0 R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1 Colour White White White White Weight kg HxWxD mm 55x1100x500 55x1500x500 55x1500x500 55x1500x500 Outdoor Unit RZQS71B7V3B RZQS100B7V3B RZQS125C7V1 RZQS140C7V1 Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 49 (43) 51 (45) 51 (49) 52 (50) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~ ~46.0-5~46-5~46 Heating Min~Max CWB -15.0~ ~ ~ ~15.5 R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

52 FBQ-B / RZQ-B/C Concealed ceiling unit BRC1D52 FBQ100,125,140B RZQ100,125,140C Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms. Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa standard 2 steps heat pump 35~60 Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 3.21 / / / / / / / 3.21 Annual energy consumption kwh Energy Label Cooling / heating A / A A / A B / B B / B C / C C / C Dimensions (Height x Width x Depth) mm 300x1000x x1400x x1400x x1400x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / / / Heating High/Low m³/min 19 / / / / Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / / 32.0 Heating High/Low dba 34.0 / / / / 32.0 R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1 Colour White White White White Weight kg HxWxD mm 55x1500x500 55x1500x500 55x1500x500 55x1500x500 Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B RZQ125C7V1B RZQ125B8W1B RZQ140C7V1B RZQ140B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) 50 (46) 50 (45) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~ ~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

53 FDQ-B / RR-B Concealed Ceiling Unit Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges from 150 till 250Pa Optimum air distribution BRC1D52 FDQ125B 3 steps: FDQ125 RR125B COOLING ONLY NON- Indoor Units FDQ125B8V3B Capacity Cooling capacity Standard kw 12.5 EER Nominal 2.61 Energy Label Cooling D Annual energy consumption kwh 2395 Dimensions (Height x Width x Depth) mm 350x1400x662 Weight kg 59.0 Air Flow Rate Cooling Medium m³/min 43.0 Sound Power Cooling Medium dba 75.0 Sound Pressure Cooling High dba ~/230V/50Hz Outdoor Unit RR125B8W1B Dimensions (Height x Width x Depth) mm 1170x900x320 Weight kg 106 Operation Range Cooling Min~Max CDB -15.0~46.0 Sound Level (nominal) Sound Power Cooling dba 67.0 Sound Pressure Cooling dba N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 58

54 FDQ-B/RQ-B Concealed Ceiling Unit Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges from 150 till 250Pa Optimum air distribution BRC1D52 FDQ125B 3 steps: FDQ125 RQ125B NON- Indoor Units FDQ125B8V3B Capacity Cooling capacity Standard kw 12.5 Heating capacity Standard kw 14.6 Annual energy consumption kwh 2395 EER / COP Cooling / Heating 2.61 / 3.24 Energy Label cooling / heating D / C Dimensions (Height x Width x Depth) mm 350x1400x662 Weight kg 59.0 Air Flow Rate Cooling Medium m³/min 43.0 Heating Medium m³/min 43.0 Sound Power Cooling Medium dba 75.0 Sound Pressure Cooling High dba 44.0 Heating Low dba ~/230V/50Hz Outdoor Unit RQ125B8W1B Dimensions (Height x Width x Depth) mm 1170x900x320 Weight kg 108 Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 Sound Level (nominal) Sound Power Cooling dba 67.0 Sound Pressure Cooling dba N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 59

55 FDQ-B / RZQS-C Concealed ceiling unit Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges from 150 till 250Pa Optimum air distribution BRC1D52 FDQ125B standard 3 steps: FDQ125 RZQS125C Indoor Units FDQ125B8V3B Nominal Capacity Cooling capacity Standard kw 12.5 Heating capacity Standard kw 14.0 Annual energy consumption kwh 2225 EER / COP Cooling / Heating 2.81 / 3.43 Energy Label cooling / heating C / B Dimensions (Height x Width x Depth) mm 350x1400x662 Weight kg 59.0 Air Flow Rate Cooling Medium m³/min 43.0 Heating Medium m³/min 43.0 Sound Power Cooling Medium dba 75.0 Sound Pressure Cooling High dba 44.0 Heating Low dba ~/230V/50Hz Outdoor Unit RZQS125C7V1 Dimensions (Height x Width x Depth) mm 1170x900x320 Weight kg 103 Sound pressure level Cooling (Night quiet mode) dba 51 (49) Heating dba 53 Sound power level Cooling dba 67 Operation Range Cooling Min~Max CDB -5~46 Heating Min~Max CWB -15~15.5 1~/230V/50Hz Piping connections Liquid (OD)/Gas mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 50 Max. internunit level difference m 30 60

56 FDQ-B / RZQ-B/C Concealed ceiling unit Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges from 150 till 250Pa Optimum air distribution BRC1D52 FDQ200,250B RZQ125B standard 2 steps: FDQ250, 3 steps: FDQ125,200 Indoor Units FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 3.01 / / / / 3.21 Annual energy consumption kwh Energy Label cooling / heating B / A A / B C / C Dimensions (Height x Width x Depth) mm 350x1400x x1400x x1400x900 Weight kg Air Flow Rate Cooling Medium m³/min Heating Medium m³/min Sound Power Cooling Medium dba Sound Pressure Cooling High dba Heating Low dba R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Outdoor Unit RZQ125C7V1B RZQ125B8W1B RZQ200C7Y1B RZQ250C7Y1B Dimensions (Height x Width x Depth) mm 1170x900x x900x x930x x930x765 Weight kg Sound pressure level Cooling (Night quiet mode) dba 50 (45) 50 (45) 57 (-) 57 (-) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~46.0 Heating Min~Max CWB -20.0~ ~ ~ ~15.0 R-410A R-410A R-410A 1~/ V/50Hz 3N~/400V/50Hz 3N~/ V/50Hz 3N~/ V/50Hz Piping connections Liquid (OD)/Gas mm 9.52 / 15.9 / / 15.9 / / 22,2 / / 22,2 / - Piping Length (Maximum) m Max. internunit level difference m

57 FFQ-B / RKS-E 4-Way blow ceiling mounted cassette (600mm x 600mm) New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and temperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply removing the suction grille; therefore maintenance can be done very easily. BRC1D52 BRC7E531 FFQ 25,35B RKS 25,35E heat pump standard 2 steps COOLING ONLY Indoor Units FFQ25B8V1B FFQ35B8V1B Nominal Capacity Cooling capacity Standard kw EER Nominal Annual energy consumption kwh Energy Label cooling A B Dimensions (Height x Width x Depth) mm 286x575x x575x575 Weight kg Air Flow Rate Cooling High/Low m³/min 9.0 / / 6.5 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 29.5 / / 25.0 R-410A 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYFQ60BAW1 BYFQ60BAW1 Colour White(RAL 9010) White(RAL 9010) HxWxD mm 55x700x700 55x700x700 Weight kg Outdoor Unit RKS25E2V1B RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound pressure level H/L dba 46 / / 44 Sound power level H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

58 FFQ-B / RKS-F 4-Way blow ceiling mounted cassette (600mm x 600mm) New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and temperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply removing the suction grille; therefore maintenance can be done very easily. BRC1D52 BRC7E531 FFQ50,60B RKS50,60F heat pump standard 2 steps COOLING ONLY Indoor Units FFQ50B8V1B FFQ60B8V1B Nominal Capacity Cooling capacity Standard kw EER Nominal Annual energy consumption kwh Energy Label cooling D D Dimensions (Height x Width x Depth) mm 286x575x x575x575 Weight kg Air Flow Rate Cooling High/Low m³/min 12.0 / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 36.0 / / 32.0 R-410A 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYFQ60BAW1 BYFQ60BAW1 Colour White(RAL 9010) White(RAL 9010) HxWxD mm 55x700x700 55x700x700 Weight kg Outdoor Unit RKS50F2V1B RKS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

59 FFQ-B / RXS-E 4-Way blow ceiling mounted cassette (600mm x 600mm) New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and temperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and maintenance BRC1D52 BRC7E531 The switch box can be reached by simply removing the suction grille; therefore maintenance can be done very easily. FFQ25,35B RXS25,35E heat pump standard 2 steps Indoor Units FFQ25B8V1B FFQ35B8V1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 3.42 / / 3.33 Annual energy consumption kwh Energy Label cooling / heating A / B B / C Dimensions (Height x Width x Depth) mm 286x575x x575x575 Weight kg Air Flow Rate Cooling High/Low m³/min 9.0 / / 6.5 Heating High/Low m³/min 9.0 / / 6.5 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 29.5 / / 25.0 Heating High/Low dba 29.5 / / 25.0 R-410A 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYFQ60BAW1 BYFQ60BAW1 Colour White(RAL 9010) White(RAL 9010) HxWxD mm 55x700x700 55x700x700 Weight kg Outdoor Unit RXS25E2V1B RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x x765x285 Weight kg Sound pressure level Cooling H/L dba 46 / / 44 Heating H/L dba 47 / / 45 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~20-15~20 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / / 9.5 / 18 Piping Length (Maximum) m Max. internunit level difference m

60 FFQ-B / RXS-F 4-Way blow ceiling mounted cassette (600mm x 600mm) BRC1D52 BRC7E531 FFQ50,60B RXS50,60F New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and temperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply removing the suction grille; therefore maintenance can be done very easily. heat pump standard 2 steps Indoor Units FFQ50B8V1B FFQ60B8V1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.61 / / 2.81 Annual energy consumption kwh Energy Label cooling / heating D / D D / D Dimensions (Height x Width x Depth) mm 286x575x x575x575 Weight kg Air Flow Rate Cooling High/Low m³/min 12.0 / / 10.0 Heating High/Low m³/min 12.0 / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 36.0 / / 32.0 Heating High/Low dba 36.0 / / 32.0 R-410A 1~/230V/50Hz 1~/230V/50Hz Decoration Panel Model BYFQ60BAW1 BYFQ60BAW1 Colour White(RAL 9010) White(RAL 9010) HxWxD mm 55x700x700 55x700x700 Weight kg Outdoor Unit RXS50F2V1B RXS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Heating H/L dba 48 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~18-15~18 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m

61 71

62 FCQ-C / RKS-F Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F533 FCQ35C heat pump 2 steps RKS35F COOLING ONLY Indoor Units FCQ35C7VEB Nominal Capacity Cooling capacity Minimum kw 1.4 Standard kw 3.4 Maximum kw 3.7 EER Nominal 3.58 Annual energy consumption kwh 475 Energy Label cooling A Dimensions (Height x Width x Depth) mm 204x840x840 Weight kg 19 Air Flow Rate Cooling High/Low m³/min 10.5 / 8.5 Sound Power Cooling High dba 49 Sound Pressure Cooling High/Low dba 31 / 27 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 Colour Pure White (RAL 9010) HxWxD mm 50x950x950 Outdoor Unit RKS35F2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 34 Sound pressure level Cooling H dba 47 / 44 Sound power level Cooling H dba 62 Operation Range Cooling Min~Max CDB -10~+46 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 20 Piping Length (Maximum) m 20 72

63 FCQ-C / RKS-F Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F533 FCQ50,60C heat pump 2 steps RKS50,60F COOLING ONLY Indoor Units FCQ50C7VEB FCQ60C7VEB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling A A Dimensions (Height x Width x Depth) mm 204x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 12.5 / / 8.5 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 31 / / 28 R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 Outdoor Unit RKS50F2V1B RKS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

64 FCQ-C7 / RXS-F Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQ35C heat pump 2 steps RXS35F Indoor Units FCQ35C7VEB Nominal Capacity Cooling capacity Minimum kw 1.4 Standard kw 3.4 Maximum kw 3.7 Heating capacity Minimum kw 1.4 Standard kw 4.2 Maximum kw 5.0 EER / COP Cooling / Heating 3.58 / 3.41 Annual energy consumption kwh 475 Energy Label cooling / heating A / B Dimensions (Height x Width x Depth) mm 204x840x840 Weight kg 19 Air Flow Rate Cooling High/Low m³/min 10.5 / 8.5 Heating High/Low m³/min 12.5 / 10.0 Sound Power Cooling High dba 49 Sound Pressure Cooling High/Low dba 31 / 27 Heating High/Low dba 31 / 27 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 Colour Pure White (RAL 9010) HxWxD mm 50x950x950 Outdoor Unit RXS35F2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 34 Sound pressure level Cooling H/L dba 47 / 44 Heating H/L dba 48 / 45 Sound power level Cooling H dba 62 Operation Range Cooling Min~Max CDB -10~46 Heating Min~Max CWB -15~20 1~/ V/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 20 Piping Length (Maximum) m 20 74

65 FCQ-C / RXS-F Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQ50,60C heat pump 2 steps RXS50,60F Indoor Units FCQ50C7VEB FCQ60C7VEB Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 3.55 / / 3.52 Annual energy consumption kwh Energy Label cooling / heating A / A A / B Dimensions (Height x Width x Depth) mm 204x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 12.5 / / 8.5 Heating High/Low m³/min 12.5 / / 8.5 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 31 / / 28 Heating High/Low dba 31 / / 28 R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 Outdoor Unit RXS50F2V1B RXS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Heating H/L dba 48 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~18-15~18 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m

66 FCQ-C/RR-B Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F533 FCQ100,125C heat pump 2 steps RR100B COOLING ONLY NON- Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB Nominal Capacity Cooling capacity Standard kw EER Nominal Annual energy consumption kwh Energy Label cooling D D C D Dimensions (Height x Width x Depth) mm 204x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 15.5 / / / 19.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 33 / / / 35 R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 50x950x950 Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -15.0~46.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 77

67 FCQ-C / RQ-B Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQ100,125C heat pump 2 steps RQ100B NON- Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.61 / / / / / 2.89 Annual energy consumption kwh Energy Label cooling / heating D / D D / D C / D D / D Dimensions (Height x Width x Depth) mm 204x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 15.5 / / / 19.0 Heating High/Low m³/min 16.0 / / / 19.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 33 / / / 35 Heating High/Low dba 34 / / / 35 R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 50x950x950 Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 78

68 FCQ-C / RZQS-B/C Round Flow Cassette BRC1D52 BRC7F532 FCQ100,125,140C RZQS125,140C Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket heat pump 2 steps Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.89 / / / / 2.81 Annual energy consumption kwh Energy Label cooling / heating C / D D / C B / D D / D Dimensions (Height x Width x Depth) mm 204x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 15.5 / / / / 19.0 Heating High/Low m³/min 16.0 / / / / 19.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 33 / / / / 35 Heating High/Low dba 34 / / / / 35 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 50x950x950 50x950x950 Outdoor Unit RZQS71B7V3B RZQS100B7V3B RZQS125C7V1 RZQS140C7V1 Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 49 (43) 51 (45) 51 (49) 52 (50) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~ ~46.0-5~46-5~46 Heating Min~Max CWB -15.0~ ~ ~ ~15.5 R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

69 FCQ-C / RZQ-B/C Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQ100,125,140C heat pump 2 steps RZQ100,125,140C Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 3.29 / / / / / / / 2.81 Annual energy consumption kwh Energy Label cooling / heating A / D A / A A / B A / B A / C D / C D / D Dimensions (Height x Width x Depth) mm 204x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 15.5 / / / / 19.0 Heating High/Low m³/min 16.0 / / / / 19.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 33 / / / / 35 Heating High/Low dba 35 / / / / 35 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 50x950x950 50x950x950 Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B RZQ125C7V1B RZQ125B8W1B RZQ140C7V1B RZQ140B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) 50 (46) 50 (45) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~ ~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

70 FCQH-C / RZQS-B/C Round Flow Cassette Improved operating effi ciency Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQH71C heat pump 2 steps RZQS71,100B Indoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEB Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.70 / / / / 3.21 Annual energy consumption kwh Energy Label cooling / heating D / B C / B A / B C / C Dimensions (Height x Width x Depth) mm 246x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 20.0 / / / / 21.5 Heating High/Low m³/min 20.0 / / / / 21.5 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34 / / / / 38 Heating High/Low dba 34 / / / / 38 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 50x950x950 50x950x950 Outdoor Unit RZQS71B7V3B RZQS100B7V3B RZQS125C7V1 RZQS140C7V1 Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 49 (43) 51 (45) 51 (49) 52 (50) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~ ~46.0-5~46-5~46 Heating Min~Max CWB -15.0~ ~ ~ ~15.5 R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

71 FCQH-C / RZQ-B/C Round Flow Cassette Improved operating effi ciency Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air fl ow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQH100,125,140C heat pump 2 steps RZQ125B Indoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEB Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 3.58 / / / / / / / 3.54 Annual energy consumption kwh Energy Label Cooling / Heating A / A A / A A / A A / A A / A B / A B / B Dimensions (Height x Width x Depth) mm 246x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 20.0 / / / / 21.5 Heating High/Low m³/min 20.0 / / / / 21.5 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34 / / / / 38 Heating High/Low dba 34 / / / / 38 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD mm 50x950x950 50x950x950 50x950x950 50x950x950 Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B RZQ125C7V1B RZQ125B8W1B RZQ140C7V1B RZQ140B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) 50 (46) 50 (45) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~ ~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

72 FUQ-B / RR-B 4-Way Blow Ceiling Suspended Cassette Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install BRC1D52 BRC7C529 FUQ71B standard heat pump RR71B 2 steps COOLING ONLY NON- Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Nominal Capacity Cooling capacity Standard kw EER Nominal Energy Label cooling / heating D D D Annual energy consumption kwh Dimensions (Height x Width x Depth) mm 165x895x x895x895 Weight kg Air Flow Rate H/L m³/min 19/14 29/21 32/23 Sound Pressure level Cooling H/L dba 40/35 43/38 44/39 Sound Power level Cooling H/L dba 56/51 59/54 60/55 1~/230V/50Hz Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -15.0~46.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 84

73 FUQ-B / RQ-B Cooling Only/Heat Pump FUQ71B Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install BRC1D52 BRC7C529 standard RQ100B heat pump 2 steps NON- Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw Annual energy consumption kwh EER / COP Cooling / Heating 2.63 / / / / / 2.97 Energy Label cooling / heating D / D D / C D / D Dimensions (Height x Width x Depth) mm 165x895x x895x895 Weight kg Air Flow Rate Cooling Medium m³/min 19/14 29/21 32/23 Heating Medium m³/min 19/14 29/21 32/23 Sound Power Cooling H/L dba 56/51 59/54 60/55 Sound Pressure Cooling H/L dba 40/35 43/38 44/39 Heating H/L dba 40/35 43/38 44/39 1~/ V/50Hz Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 85

74 FUQ-B / RZQ-B/C Cooling Only/Heat Pump FUQ71B Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install BRC1D52 BRC7C528 RZQ100,125B heat pump standard 2 steps Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw Annual energy consumption kwh EER / COP Cooling / Heating 3.21 / / / / / 3.21 Energy Label Cooling / Heating A / B A / C A / B B / C B / C Dimensions HxWxD mm 165x895x x895x895 Weight kg Sound power level Cooling H/L db(a) 56/51 59/54 60/55 Sound pressure level Cooling H/L db(a) 40/35 43/38 44/39 Heating H/L db(a) 40/35 43/38 44/39 R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B RZQ125C7V1B RZQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

75 87 _

76 FHQ-B / RKS-E Ceiling suspended unit Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E66 FHQ35B RKS35E heat pump 2 steps 35~60 COOLING ONLY Indoor Units FHQ35BVV1B Nominal Capacity Cooling capacity Minimum kw 1.4 Standard kw 3.4 Maximum kw 3.7 EER Nominal 3.24 Annual energy consumption kwh 525 Energy Label cooling A Dimensions (Height x Width x Depth) mm 195x960x680 Weight kg 24.0 Air Flow Rate Cooling High/Low m³/min 13.0 / 10.0 Sound Power Cooling High/Low dba 53.0 / 48.0 Sound Pressure Cooling High/Low dba 37.0 / ~/ V/50Hz Outdoor Unit RKS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 32 Sound pressure level Cooling H/L dba 47 / 44 Sound power level Cooling H dba 62 Operation Range Cooling Min~Max CDB -10~46 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 20 Max. internunit level difference m 15 88

77 FHQ-B / RKS-F Ceiling suspended unit Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E66 FHQ50B RKS50,60F heat pump 2 steps 35~60 COOLING ONLY Indoor Units FHQ50BVV1B FHQ60BVV1B Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw EER Nominal Annual energy consumption kwh Energy Label cooling D D Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / 13.0 Sound Power Cooling High/Low dba 54.0 / / 49.0 Sound Pressure Cooling High/Low dba 38.0 / / 33.0 R-410A 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RKS50F2V1B RKS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m Max. internunit level difference m

78 FHQ-B / RXS-E Ceiling suspended unit Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E63 FHQ35B RXS35E heat pump 2 steps 35~60 Indoor Units FHQ35BVV1B Nominal Capacity Cooling capacity Minimum kw 1.4 Standard kw 3.4 Maximum kw 3.7 Heating capacity Minimum kw 1.2 Standard kw 4.0 Maximum kw 5.0 EER / COP Cooling / Heating 3.24 / 3.60 Annual energy consumption kwh 525 Energy Label cooling / heating A / B Dimensions (Height x Width x Depth) mm 195x960x680 Weight kg 24.0 Air Flow Rate Cooling High/Low m³/min 13.0 / 10.0 Heating High/Low m³/min 13.0 / 10.0 Sound Power Cooling High/Low dba 53.0 / 48.0 Sound Pressure Cooling High/Low dba 37.0 / 32.0 Heating High/Low dba 37.0 / ~/ V/50Hz Outdoor Unit RXS35E2V1B Dimensions (Height x Width x Depth) mm 550x765x285 Weight kg 32 Sound pressure level Cooling H/L dba 47 / 44 Heating H/L dba 48 / 45 Sound power level Cooling H dba 62 Operation Range Cooling Min~Max CDB -10~46 Heating Min~Max CWB -15~20 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 9.5 / 18 Piping Length (Maximum) m 20 90

79 FHQ-B / RXS-F Ceiling suspended unit Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E63 FHQ50B RXS50,60F heat pump 2 steps 35~60 Indoor Units FHQ50BVV1B FHQ60BVV1B Nominal Capacity Cooling capacity Minimum kw Standard kw Maximum kw Heating capacity Minimum kw Standard kw Maximum kw EER / COP Cooling / Heating 2.73 / / 2.89 Annual energy consumption kwh Energy Label cooling / heating D / D D / D Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / 13.0 Heating High/Low m³/min 13.0 / / 13.0 Sound Power Cooling High/Low dba 54.0 / / 49.0 Sound Pressure Cooling High/Low dba 38.0 / / 33.0 Heating High/Low dba 38.0 / / 33.0 R-410A 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RXS50F2V1B RXS60F2V1B Dimensions (Height x Width x Depth) mm 735x825x x825x300 Weight kg Sound pressure level Cooling H/L dba 47 / / 46 Heating H/L dba 48 / / 46 Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -10~46-10~46 Heating Min~Max CWB -15~18-15~18 R-410A 1~/ V/50Hz 1~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / / 12.7 / 18 Piping Length (Maximum) m

80 FHQ-B / RR-B Ceiling Suspended Unit FHQ71B Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E66 heat pump RR100B 2 steps COOLING ONLY NON- Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw EER Nominal Energy Label Cooling D D D Annual energy consumption kwh Dimensions (Height x Width x Depth) mm 195x1160x x1400x x1590x680 Weight kg Air Flow Rate Cooling High/Low m³/min 17.0 / / / 25.0 Sound Power Cooling High/Low dba 55.0 / / / 55.0 Sound Pressure Cooling High/Low dba 39.0 / / / ~/ V/50Hz Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -15.0~46.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 93

81 FHQ-B / RQ-B Ceiling Suspended Unit FHQ71B Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E63 heat pump RQ100B 2 steps NON- Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw Heating capacity Standard kw Annual energy consumption kwh EER / COP Cooling / Heating 2.63 / / / / / 2.81 Energy Label cooling / heating D / D D / E D / D Dimensions (Height x Width x Depth) mm 195x1160x x1400x x1590x680 Weight kg Air Flow Rate Cooling High/Low m³/min 17.0 / / / 25.0 Heating High/Low m³/min 17.0 / / / 25.0 Sound Power Cooling High/Low dba 55.0 / / / 55.0 Sound Pressure Cooling High/Low dba 39.0 / / / 39.0 Heating High/Low dba 39.0 / / / ~/ V/50Hz Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m 30 94

82 FHQ-B / RZQS-B/C Ceiling suspended unit FHQ71B Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E63 RZQS125C heat pump 2 steps Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw Annual energy consumption kwh EER / COP Cooling / Heating 2.81 / / / 2.82 Energy Label cooling / heating C / D E / D D / D Dimensions (Height x Width x Depth) mm 195x1160x x1400x x1590x680 Weight kg Air Flow Rate Cooling High/Low m³/min 17.0 / / / 25.0 Heating High/Low m³/min 17.0 / / / 25.0 Sound Power Cooling High/Low dba 55.0 / / / 55.0 Sound Pressure Cooling High/Low dba 39.0 / / / 39.0 Heating High/Low dba 39.0 / / / 39.0 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RZQS71B7V3B RZQS100B7V3B RZQS125C7V1 Dimensions (Height x Width x Depth) mm 770x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 49 (43) 51 (45) 51 (49) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~ ~ ~46.0 Heating Min~Max CWB -15.0~ ~ ~15.5 R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

83 FHQ-B / RZQ-B/C Ceiling Suspended unit Ideal solution for shops, restaurants or offi ces without false ceilings Compact design Leaves maximum fl oor and wall space for furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m without loss of capacity. BRC1D52 BRC7E63 FUQ71B RZQ100,125C heat pump 2 steps Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Nominal Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating 2.89 / / / / / 3.11 Annual energy consumption kwh Energy Label cooling / heating A / D B / C B / D C / D Dimensions (Height x Width x Depth) mm 195x1160x x1400x x1590x680 Weight kg Air Flow Rate Cooling High/Low m³/min 17.0 / / / 25.0 Heating High/Low m³/min 17.0 / / / 25.0 Sound Power Cooling High/Low dba 55.0 / / / 55.0 Sound Pressure Cooling High/Low dba 39.0 / / / 39.0 Heating High/Low dba 39.0 / / / 39.0 R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B RZQ125C7V1B RZQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

84 Twin / triple / double twin applications & Multi Model applications 98

85 It is possible to connect 2,3 or 4 indoor units to a single outdoor unit. The indoor units may be of different types (e.g. 4-way blow ceiling mounted cassette, wall mounted,...) and even different capacities (e.g. 35 and 71 class). All indoor units are operated together within the same mode (cooling or heating) from one remote control. This allows equal air distribution, even in larger, irregularly shaped rooms. The total capacities (outdoor base) for simultaneous operation are the same as for the pair applications. Connectable indoor units: Inverter controlled: RZQ-B/C: FCQH-C, FCQ-C, FHQ-B, FUQ-B, FAQ-B, FDQ-B RZQS-B/C: FCQH-C, FCQ-C, FFQ-B, FBQ-B, FHQ-B, FAQ-B, FDQ-B Non-inverter controlled: RR-B, RQ-B: FFQ-B, FBQ-B, FCQ-C, FHQ-B, FUQ-B, FAQ-B R(Y)P-B: FHYBP-B, FDYP-B POSSIBLE COMBINATIONS TWIN TRIPLE DOUBLE TWIN RZQ71 RZQS71 RR71 RQ (KHRQ22M20TA) RZQ100 RZQS100 RR100 RQ100 RZQ125 RZQS125 RR125 RQ125 RZQ140 RZQS140 RZQ200 RZQ250 R(Y)P200 R(Y)P (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M64T) (KHRQ22M64T) (KHRQ22M20TA) (KHRQ22M20TA) (KHRQ22M64T) (KHRQ22M20TA) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ22M20TA) (KHRQ250H7) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ250H7) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (KHRQ127H) (3 x KHRQ22M20TA) (3 x KHRQ22M20TA) (3 x KHRQ22M20TA) (3 x KHRQ22M20TA) (2 x KHRQ22M20TA + KHRQ22M64T) (2 x KHRQ22M20TA + KHRQ22M64T) 99

86 FAQ,FBQ,FCQ, FCQH,FFQ,FHQ + RZQS Indoor Units FAQ71BVV1B Dimensions (Height x Width x Depth) mm 290x1050x230 Weight kg 13.0 Air Flow Rate Cooling High/Low m³/min 19.0 / 15.0 Heating High/Low m³/min 19.0 / 15.0 Sound Power Cooling High/Low dba 59.0 / 53.0 Sound Pressure Cooling High/Low dba 43.0 / 37.0 Heating High/Low dba 43.0 / ~/ V/50Hz Indoor Units FBQ71B8V3B FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 Dimensions (Height x Width x Depth) mm 300x1000x x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / 9 14 / / 14 Heating High/Low m³/min / / 9 14 / / 14 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / 30 Heating High/Low dba 34.0 / / / 30 1~/230V/50Hz Indoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB Dimensions (Height x Width x Depth) mm 204x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m²/min 10.0 / / / / 9.0 Heating High/Low m²/min 12.5 / / / / 9.5 Sound Power level Cooling High dba Sound Pressure Cooling High/Low dba 31 / / / / 28 Heating High/Low dba 31 / / / / 28 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 100

87 Indoor Units FCQH71CVEB Dimensions (Height x Width x Depth) mm 246x840x840 Weight kg 23 Air Flow Rate Cooling High/Low m²/min 20.0 / 12.0 Heating High/Low m²/min 20.0 / 12.0 Sound Power level Cooling High dba 52.0 Sound Pressure Cooling High/Low dba 34 / 28 Heating High/Low dba 34 / 28 1~/ V/50/60Hz Indoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B Dimensions (Height x Width x Depth) mm 286x575x575 Weight kg 17,5 Air Flow Rate Cooling High/Low m³/min 10.0 / / / 10.0 Heating High/Low m³/min 10.0 / / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 32.0 / / / 32.0 Heating High/Low dba 32.0 / / / ~/230V/50Hz Indoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1B Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / / 14.0 Heating High/Low m³/min 13.0 / / / 14.0 Sound Power Cooling High/Low dba 53.0 / / / / 51.0 Sound Pressure Cooling High/Low dba 37.0 / / / / 35.0 Heating High/Low dba 37.0 / / / / ~/ V/50Hz Outdoor Unit RZQS71B7V3B RZQS100B7V3B RZQS125C7V1 RZQS140C7V1 Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x320 Weight kg Sound pressure level Cooling (Night quiet mode) dba 49 (43) 51 (45) 51 (49) 52 (50) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~ ~46.0-5~46-5~46 Heating Min~Max CWB -15.0~ ~ ~ ~15.5 R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / 26 Piping Length (Maximum) m Max. internunit level difference m

88 FAQ,FBQ,FCQ,FCQH, FDQ,FFQ,FHQ, FUQ + RZQ Indoor Units FAQ71BVV1B FAQ100BVV1B Dimensions (Height x Width x Depth) mm 290x1050x x1570x200 Weight kg Air Flow Rate Cooling High/Low m³/min 19.0 / / 19.0 Heating High/Low m³/min 19.0 / / 19.0 Sound Power Cooling High/Low dba 59.0 / / 57.0 Sound Pressure Cooling High/Low dba 43.0 / / 41.0 Heating High/Low dba 43.0 / / ~/ V/50Hz Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 Dimensions (Height x Width x Depth) mm 300x1000x x1400x x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / / / 9 14 / / 14 Heating High/Low m³/min / / / / 9 14 / / 14 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / / / 30 Heating High/Low dba 34.0 / / / / / 30 1~/230V/50Hz Indoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB Dimensions (Height x Width x Depth) mm 214x840x x840x x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m²/min 10.0 / / / / / / 19.0 Heating High/Low m²/min 12.5 / / / / / / 19.0 Sound Power level Cooling High dba Sound Pressure Cooling High/Low dba 31 / / / / / / 35 Heating High/Low dba 31 / / / / / / 35 R-410A R-410A R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Indoor Units FCQH71C7VEB Dimensions (Height x Width x Depth) mm 256x840x840 Weight kg 23 Air Flow Rate Cooling High/Low m²/min 20.0 / 12.0 Heating High/Low m²/min 20.0 / 12.0 Sound Power level Cooling High dba 52.0 Sound Pressure Cooling High/Low dba 34 / 28 Heating High/Low dba 34 / 28 1~/ V/50/60Hz 102

89 Indoor Units FDQ125B8V3B Dimensions (Height x Width x Depth) mm 350x1400x662 Weight kg 59.0 Air Flow Rate Cooling Medium m³/min 43.0 Heating Medium m³/min 43.0 Sound Power Cooling Medium dba 75.0 Sound Pressure Cooling High dba 44.0 Heating Low dba ~/230V/50Hz Indoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B Dimensions (Height x Width x Depth) mm 286x575x575 Weight kg 17.5 Air Flow Rate Cooling High/Low m³/min 10.0 / / / 10.0 Heating High/Low m³/min 10.0 / / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 32.0 / / / 32.0 Heating High/Low dba 32.0 / / / ~/230V/50Hz Indoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Dimensions (Height x Width x Depth) mm 195x960x x1160x x1400x x1590x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / / / / 25.0 Heating High/Low m³/min 13.0 / / / / / 25.0 Sound Power Cooling High/Low dba 53.0 / / / / / / 55.0 Sound Pressure Cooling High/Low dba 37.0 / / / / / / 39.0 Heating High/Low dba 37.0 / / / / / / ~/ V/50Hz Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Dimensions (Height x Width x Depth) mm 165x895x x895x895 Weight kg Air Flow Rate Cooling High/Low m³/min 19/14 29/21 32/23 Heating High/Low m³/min 19/14 29/21 32/23 Sound Power Cooling High/Low dba 40/35 43/38 44/39 Sound Pressure Cooling High/Low dba 56/51 59/54 60/55 Heating High/Low dba 56/51 59/54 60/55 1~/ V/50Hz Outdoor Unit RZQ71B9V3B1 RZQ100C7V1B RZQ100B8W1B RZQ125C7V1B RZQ125B8W1B RZQ140C7V1B RZQ140B8W1B RZQ200C7Y1B RZQ250C7Y1B Dimensions (Height x Width x Depth) mm 770x900x x900x x900x x900x x900x x900x x900x x930x x930x765 Weight kg Sound pressure level Cooling (Night quiet mode) dba 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) 50 (46) 50 (45) 57 (-) 57 (-) Heating dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -15.0~ ~ ~ ~ ~ ~ ~ ~ ~50.0 Heating Min~Max CWB -20.0~ ~ ~ ~ ~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A 1~/230V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 3N~/ V/50Hz 3N~/ V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 15.9 / / 22.2 / / 22.2 / - Piping Length (Maximum) m Max. internunit level difference m

90 FAQ,FBQ,FCQ, FFQ,FHQ + RR COOLING ONLY Indoor Units FAQ71BVV1B Dimensions (Height x Width x Depth) mm 290x1050x230 Weight kg 13.0 Air Flow Rate Cooling High/Low m³/min 19.0 / 15.0 Sound Power Cooling High/Low dba 59.0 / 53.0 Sound Pressure Cooling High/Low dba 43.0 / ~/ V/50Hz COOLING ONLY Indoor Units FBQ60B8V1 FBQ35B8V1 FBQ50B8V1 FBQ71B8V3B Dimensions (Height x Width x Depth) mm 300x1000x x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min 19 / / 9 14 / / Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34 / / / ~/230V/50Hz COOLING ONLY Indoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB Dimensions (Height x Width x Depth) mm 214x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m²/min 10.0 / / / / 9.0 Sound Power level Cooling High dba Sound Pressure level Cooling High/Low dba 31 / / / / 28 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 104

91 COOLING ONLY Indoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B Dimensions (Height x Width x Depth) mm 286x575x575 Weight kg 17.5 Air Flow Rate Cooling High/Low m³/min 10.0 / / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 32.0 / / / ~/230V/50Hz COOLING ONLY Indoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1B Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / / 14.0 Sound Power Cooling High/Low dba 53.0 / / / / 51.0 Sound Pressure Cooling High/Low dba 37.0 / / / / ~/ V/50Hz COOLING ONLY Indoor Units FUQ71BVV1B Dimensions (Height x Width x Depth) mm 165x895x895 Weight kg 25 Air Flow Rate Cooling High/Low m³/min 19/14 Sound Power Cooling High/Low dba 40/35 Sound Pressure Cooling High/Low dba 56/51 1~/ V/50Hz COOLING ONLY NON- Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling H dba Sound power level Cooling H dba Operation Range Cooling Min~Max CDB -15.0~46.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m

92 FAQ,FBQ,FCQ,FFQ, FHQ,FUQ + RQ Indoor Units FAQ71BVV1B Dimensions (Height x Width x Depth) mm 290x1050x230 Weight kg 13.0 Air Flow Rate Cooling High/Low m³/min 19.0 / 15.0 Heating High/Low m³/min 19.0 / 15.0 Sound Power Cooling High/Low dba 59.0 / 53.0 Sound Pressure Cooling High/Low dba 43.0 / 37.0 Heating High/Low dba 43.0 / ~/ V/50Hz Indoor Units FBQ71B8V3B FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 Dimensions (Height x Width x Depth) mm 300x1000x x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min / / 9 14 / / 14 Heating High/Low m³/min / / 9 14 / / 14 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 34.0 / / / 30 Heating High/Low dba 34.0 / / / 30 1~/230V/50Hz Indoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB Dimensions (Height x Width x Depth) mm 204x840x x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m²/min 10.0 / / / / 9.0 Heating High/Low m²/min 12.5 / / / / 9.5 Sound Power level Cooling High dba Sound Pressure Cooling High/Low dba 31 / / / / 28 Heating High/Low dba 31 / / / / 28 R-410A R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 106

93 Indoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B Dimensions (Height x Width x Depth) mm 286x575x575 Weight kg 17.5 Air Flow Rate Cooling High/Low m³/min 10.0 / / / 10.0 Heating High/Low m³/min 10.0 / / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 32.0 / / / 32.0 Heating High/Low dba 32.0 / / / ~/230V/50Hz Indoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1B Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / / 14.0 Heating High/Low m³/min 13.0 / / / 14.0 Sound Power Cooling High/Low dba 53.0 / / / / 51.0 Sound Pressure Cooling High/Low dba 37.0 / / / / 35.0 Heating High/Low dba 37.0 / / / / ~/ V/50Hz Indoor Units FUQ71BVV1B Dimensions (Height x Width x Depth) mm 165x895x895 Weight kg 25 Air Flow Rate Cooling High/Low m³/min 19/14 Heating High/Low m³/min 19/14 Sound Power Cooling High/Low dba 40/35 Sound Pressure Cooling High/Low dba 56/51 Heating High/Low dba 56/51 - NON- Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Dimensions (Height x Width x Depth) mm 770x900x x900x320 Weight kg Sound pressure level Cooling dba Sound power level Cooling dba Operation Range Cooling Min~Max CDB -5.0~46.0 Heating Min~Max CWB -10~15 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26 Piping Length (Maximum) m 70 Max. internunit level difference m

94 MKS-E/F Multi model application Inverter controlled CONNECTABLE INDOOR UNITS 2MKS40F 2MKS50F 3MKS50E 4MKS58E 4MKS75F 5MKS90E Wall mounted unit FTKS20,25,35DW/L FTKS20,25,35DW/L FTKS20,25,35DW/L FTKS20,25,35,50DW/L FTKS20,25,35,50DW/L FTKS20,25,35,50DW/L Wall mounted unit FTKS20,25,35C FTKS20,25,35C FTKS20,25,35C FTKS20,25,35C/FTKS50F FTKS20,25,35C/FTKS50,60,71F FTKS20,25,35C/FTKS50,60,71F Floor standinig unit FVXS25,35F FVXS25,35,50F FVXS25,35F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F Flexi type unit FLKS25,35B FLKS25,35,50B FLKS25,35B FLKS25,35,50B FLKS25,35,50,60B FLKS25,35,50,60B Slim concealed ceiling unit FDKS25,35E FDKS25,35E FDKS25,35E FDKS25,35E/FDKS50C FDKS25,35E/FDKS50,60C FDKS25,35E/FDKS50,60C Concealed ceiling unit FDBQ25B/FBQ35,50B FDBQ25B/FBQ35,50,60B FDBQ25B/FBQ35,50,60B 4-way blow ceiling mounted cassette (600x600) FFQ25,35,50B FFQ25,35,50,60B FFQ25,35,50,60B Round fl ow cassette FCQ35,50C FCQ35,50,60C FCQ35,50,60C Ceiling suspended cassette FHQ35,50B FHQ35,50,60B FHQ35,50,60B Indoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 Dimensions (Height x Width x Depth) mm 300x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min 11.5 / 9 14 / / 14 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 33 / / 30 1~/230V/50Hz Indoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB Dimensions (Height x Width x Depth) mm 204x840x x840x x840x840 Weight kg Air Flow Rate Cooling High/Low m³/min 10.0/ / /8.5 Sound power level Cooling High/Low dba Sound Pressure Cooling High/Low dba 31 / / / 28 R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz Indoor Units FDKS50CVMB FDKS60CVMB Dimensions (Height x Width x Depth) mm 200x900x x1100x620 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 12.0 / 11.0 / 10.0 / / 14.8 / 13.5 / 11.2 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 35.0 / 33.0 / / 36.0 / 34.0 / ~ / V/50/60Hz 110

95 Indoor Units FDKS25EAVMB FDKS35EAVMB Dimensions (Height x Width x Depth) mm 200x700x620 Weight kg 21.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 8.0 / 7.3 / 6.2 Sound Power Cooling High dba 53.0 Sound Pressure Cooling H/M/L/SL dba 35.0 / 33.0 / 31.0 / ~/ / V/50/60Hz Indoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B Dimensions (Height x Width x Depth) mm 286x575x575 Weight kg 17.5 Air Flow Rate Cooling High/Low m³/min 9.0 / / / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 29.5 / / / / ~/230V/50Hz Indoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / 13.0 Sound Power Cooling High/Low dba 53.0 / / / 49.0 Sound Pressure Cooling High/Low dba 37.0 / / / ~/ V/50Hz Indoor Units FLKS25BAVMB FLKS35BAVMB FLKS50BAVMB FLKS60BAVMB Dimensions (Height x Width x Depth) mm 490x1050x200 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 7.60 / 6.80 / 6.00 / / 7.60 / 6.6 / / / 8.50 / / / 9.30 / 8.3 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 34.0 / 31.0 / / 35.0 / 32.0 / / 43.0 / 39.0 / / 45.0 / 41.0 / ~/ / V/50/60Hz Indoor Units FTKS20CAVMB FTKS25CAVMB FTKS35CAVMB Dimensions (Height x Width x Depth) mm 273x784x195 Weight kg 7.5 Air Flow Rate Cooling H/M/L/SL m³/min 7.70 / 5.90 / 4.20 / / 6.00 / 4.40 / 3.80 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 32.0 / 25.0 / / 33.0 / 26.0 / ~/ / V/50/60Hz Indoor Units FTKS20D3VML FTKS25D3VML FTKS35D3VML FTKS50D2V1L Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.9 / 4.8 / / 9.3 / 7.1 / 6.2 Sound Power Cooling High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 26.0 / H/M/L/SL dba / 41.0 / 35.0 / ~/ / V/50/60Hz 1~/ V/50Hz 111

96 Indoor Units FTKS20D3VMW FTKS25D3VMW FTKS35D3VMW FTKS50D2V1W Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.9 / 4.8 / / 9.3 / 7.1 / 6.2 Sound Power Cooling High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 26.0 / H/M/L/SL dba / 41.0 / 35.0 / ~ / V/50/60Hz V/50Hz Indoor Units FVXS25F FVXS35F FVXS50F Dimensions (Height x Width x Depth) mm 600x700x210 Weight kg 14.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.2 / 4.8 / / 4.9 / / 7.8 / 6.6 Sound Power Cooling High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 26.0 / / 27.0 / / 36.0 / ~/ V/50Hz Indoor Units FTKS50FV1B FTKS60FV1B FTKS71FV1B Dimensions (Height x Width x Depth) mm 290x1050x238 Weight kg 12 Air Flow Rate Cooling H/M/L/SL m³/min 14.7 / 12.4 / 10.3 / / 13.6 / 11.4 / / 14.6 / 11.6 / 10.6 Sound Power Cooling Medium dba Sound Pressure Cooling H/M/L/SL dba 43 / 39 / 34 / / 41 / 36 / / 42 / 37 / 34 1~/ V/50Hz Indoor Units FDBQ25B Dimensions (Height x Width x Depth) mm 230x652x502 Weight kg 17 Air Flow Rate Cooling H/L m³/min 6.5 / 5.2 Sound Power Cooling H/L dba 35 / 28 Sound Pressure Cooling H dba 55 1~/ V/50Hz 3MKS550E,4MKS58E 5MKS90E Outdoor Unit 2MKS40FV1B 2MKS50FV1B 3MKS50E2V1B 4MKS58E2V1B 4MKS75F2V1B 5MKS90E7V3B Dimensions (Height x Width x Depth) mm 550x765x x765x x936x x936x x900x320 Weight kg Operation Range Cooling Min~Max CDB +10~ ~ ~ ~ ~46.0 R-410A R-410A R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz 1~/ V/50Hz Piping Connections Liquid (OD)/Gas mm 6.35 / / / / 12.7 / / 15.9 / 25 Piping Length (Maximum) m 30 (for total of each room), 20 (for one room) 30 (for total of each room), 20 (for one room) 50 (for total of each room)/25 (for 1 room) 60 (for total of each room), 25 (for one room) 75(for total of each room)/25 (for 1 room) Max. internunit level difference m 7.5 (between indoor units) 7.5 (between indoor units) 15.0 (between indoor units) 15.0 (between indoor units) 7.5(between indoor units) 112

97 MXS-E/F Multi model application Inverter controlled CONNECTABLE INDOOR UNITS 2MXS40F 2MXS50F 3MXS52E 4MXS68F 4MXS80E 5MXS90E Stylish wall mounted unit FTXG25,35E FTXG25,35E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E Wall mounted unit FTXS20,25,35DW/L FTXS20,25,35DW/L FTXS20,25,35DW/L FTXS20,25,35,50DW/L FTXS20,25,35,50DW/L FTXS20,25,35,50DW/L Wall mounted unit FTXS20,25,35C FTXS20,25,35C FTXS20,25,35C/FTXS50F FTXS20,25,35C/FTXS50,60F FTXS20,25,35C/FTXS50,60,71F FTXS20,25,35C/FTXS50,60,71F Floor standinig unit FVXS25,35F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F Flexi type unit FLXS25,35B FLXS25,35,50B FLXS25,35,50B FLXS25,35,50,60B FLXS25,35,50,60B FLXS25,35,50,60B Slim concealed ceiling unit FDXS25,35E FDXS25,35E/FDXS50C FDXS25,35E/FDXS50C FDXS25,35E/FDXS50,60C FDXS25,35E/FDXS50,60C FDXS25,35E/FDXS50,60C Concealed ceiling unit - - FDBQ25B/FBQ35,50B FDBQ25B/FBQ35,50,60B FDBQ25B/FBQ35,50,60B FDBQ25B/FBQ35,50,60B 4-way blow ceiling mounted cassette (600x600) - - FFQ25,35,50B FFQ25,35,50,60B FFQ25,35,50,60B FFQ25,35,50,60B Round fl ow cassette - - FCQ35,50C FCQ35,50,60C FCQ35,50,60C FCQ35,50,60C Ceiling suspended cassette - - FHQ35,50B FHQ35,50,60B FHQ35,50,60B FHQ35,50,60B Indoor Units CTXG50EV1BW CTXG50EV1BS Dimensions (Height x Width x Depth) mm 275x840x150 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 11.3 / 9.1 / 7.1 / 6.7 Heating H/M/L/SL m³/min 12.6 / 10.6 / 8.7 / 7.7 Sound Power Cooling High dba 64.0 Heating High dba 64.0 Sound Pressure Cooling H/M/L/SL dba 47.0 / 41.0 / 35.0 / 32.0 Heating H/M/L/SL dba 47.0 / 41.0 / 35.0 / ~/ V/50Hz Indoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 Dimensions (Height x Width x Depth) mm 300x700x x1000x800 Weight kg Air Flow Rate Cooling High/Low m³/min 11.5 / 9 14 / / 14 Heating High m³/min - High/Low m³/min 11.5 / 9 14 / / 14 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Low dba 33 / / 30 Heating High/Low dba 33 / / 30 1~/230V/50Hz Indoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB Dimensions (Height x Width x Depth) mm 204x840x x840x x840x840 Weight kg Air Flow Rate Cooling H/L m³/min 10.8 / / / 8.5 Heating H/L m³/min 12.5 / / / 8.5 Sound Power Cooling H/L dba Sound Pressure Heating H/L dba 31 / / / 28 R-410A R-410A 1~/ V/50/60Hz 1~/ V/50/60Hz 1~/ V/50/60Hz 113

98 Indoor Units FDXS50CVMB FDXS60CVMB Dimensions (Height x Width x Depth) mm 200x900x x1100x620 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 12.0 / 11.0 / 10.0 / / 14.8 / 13.5 / 11.2 Heating H/M/L/SL m³/min 12.0 / 11.0 / 10.0 / / 14.8 / 13.5 / 11.2 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 35.0 / 33.0 / / 36.0 / 34.0 / 32.0 Heating H/M/L/SL dba 37.0 / 35.0 / 33.0 / / 36.0 / 34.0 / ~/ / V/50/60Hz Indoor Units FDXS25EAVMB FDXS35EAVMB Dimensions (Height x Width x Depth) mm 200x700x620 Weight kg 21.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 8.0 / 7.3 / 6.2 Heating H/M/L/SL m³/min 8.7 / 8.0 / 7.3 / 6.2 Sound Power Cooling High dba 53.0 Heating High dba 53.0 Sound Pressure Cooling H/M/L/SL dba 35.0 / 33.0 / 31.0 / 29.0 Heating H/M/L/SL dba 35.0 / 33.0 / 31.0 / ~/ / V/50/60Hz Indoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B Dimensions (Height x Width x Depth) mm 286x575x575 Weight kg 17.5 Air Flow Rate Cooling High/Low m³/min 9.0 / / / / 10.0 Heating High/Low m³/min 9.0 / / / / 10.0 Sound Power Cooling High dba Sound Pressure Cooling High/Low dba 29.5 / / / / 32.0 Heating High/Low dba 29.5 / / / / ~/230V/50Hz Indoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B Dimensions (Height x Width x Depth) mm 195x960x x1160x680 Weight kg Air Flow Rate Cooling High/Low m³/min 13.0 / / 13.0 Heating High/Low m³/min 13.0 / / 13.0 Sound Power Cooling High/Low dba 53.0 / / / 49.0 Heating High/Low dba 53.0 / / / 49.0 Sound Pressure Cooling High/Low dba 37.0 / / / 33.0 Heating High/Low dba 37.0 / / / ~/ V/50Hz Indoor Units FLXS25BAVMB FLXS35BAVMB FLXS50BAVMB FLXS60BAVMB Dimensions (Height x Width x Depth) mm 490x1050x200 Weight kg Air Flow Rate Cooling H/M/L/SL m³/min 7.60 / 6.80 / 6.00 / / 7.60 / 6.60 / / / 8.50 / / / 9.30 / 8.3 Heating H/M/L/SL m³/min 9.20 / 8.30 / 7.40 / / 8.90 / 8.00 / / 9.8 / 7.5 / / / 8.40 / 7.5 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 37.0 / 34.0 / 31.0 / / 35.0 / 32.0 / / 43.0 / 39.0 / / 45.0 / 41.0 / 39.0 Heating H/M/L/SL dba 37.0 / 34.0 / 31.0 / / 36.0 / 33.0 / / 41.0 / 35.0 / / 42.0 / 37.0 / ~/ / V/50/60Hz 114

99 Indoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BS Dimensions (Height x Width x Depth) mm 275x840x150 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 7.7 / 6.1 / 4.7 / / 6.5 / 4.9 / 4.1 Heating H/M/L/SL m³/min 9.0 / 7.9 / 6.7 / / 8.2 / 6.7 / 5.9 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 32.0 / 25.0 / / 33.0 / 26.0 / 23.0 Heating H/M/L/SL dba 38.0 / 33.0 / 28.0 / / 34.0 / 29.0 / ~/ V/50Hz Indoor Units FTXS20CAVMB FTXS25CAVMB FTXS35CAVMB Dimensions (Height x Width x Depth) mm 273x784x195 Weight kg 7.5 Air Flow Rate Cooling H/M/L/SL m³/min 7.70 / 5.90 / 4.20 / / 6.00 / 4.40 / 3.80 Heating H/M/L/SL m³/min 7.80 / 6.50 / 5.30 / / 6.70 / 5.30 / 4.60 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/M/L/SL dba 38.0 / 32.0 / 25.0 / / 33.0 / 26.0 / 23.0 Heating H/M/L/SL dba 38.0 / 33.0 / 28.0 / / 34.0 / 29.0 / ~/ / V/50/60Hz Indoor Units FTXS20D3VML FTXS25D3VML FTXS35D3VML FTXS50D2V1L Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.9 / 4.8 / / 9.3 / 7.1 / 6.2 Heating H/M/L/SL m³/min 9.4 / 7.6 / 5.8 / / 7.9 / 6.0 / / 9.4 / 7.4 / 6.3 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 26.0 / H/M/L/SL dba / 41.0 / 35.0 / 32.0 Heating H/L/SL dba 38.0 / 28.0 / / 29.0 / H/M/L/SL dba / 40.0 / 34.0 / ~/ / V/50/60Hz 1~/ V/50Hz Indoor Units FTXS20D3VMW FTXS25D3VMW FTXS35D3VMW FTXS50D2V1W Dimensions (Height x Width x Depth) mm 283x800x195 Weight kg 9.0 Air Flow Rate Cooling H/M/L/SL m³/min 8.7 / 6.7 / 4.7 / / 6.9 / 4.8 / / 9.3 / 7.1 / 6.2 Heating H/M/L/SL m³/min 9.4 / 7.6 / 5.8 / / 7.9 / 6.0 / / 9.4 / 7.4 / 6.3 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/L/SL dba 38.0 / 25.0 / / 26.0 / H/M/L/SL dba / 41.0 / 35.0 / 32.0 Heating H/L/SL dba 38.0 / 28.0 / / 29.0 / H/M/L/SL dba / 40.0 / 34.0 / ~/ / V/50/60Hz 1~/ / V/50/60Hz 1~/ V/50Hz 115

100 Indoor Units FVXS25F FVXS35F FVXS50F Dimensions (Height x Width x Depth) mm 600x700x210 Weight kg 14.0 Air Flow Rate Cooling H/L/SL m³/min 8.2 / 4.8 / / 4.9 / / 7.8 / 6.6 Heating H/L/SL m³/min 8.8 / 5.0 / / 5.2 / / 8.5 / 7.1 Sound Power Cooling High dba Heating High dba Sound Pressure Cooling H/L/SL dba 38 / 26 / / 27 / / 36 / 32 Heating H/L/SL dba 38 / 26 / / 27 / / 36 / 32 1~/ V/50Hz Indoor Units FDBQ25B Dimensions (Height x Width x Depth) mm 230x652x502 Weight kg 17 Air Flow Rate Cooling H/L/SL m³/min 6.5 / 5.2 Sound Pressure Cooling High dba 35 / 28 Heating High dba 35 / 29 Sound Power Cooling H/L/SL dba 55 1~/ V/50Hz Indoor Units FTXS50FV1B FTXS60FV1B FTXS71FV1B Dimensions (Height x Width x Depth) mm 290x1050x238 Weight kg 12 Air Flow Rate Cooling H/M/L/SL m³/min 14.7 / 12.4 / 10.3 / / 13.6 / 11.4 / / 14.6 / 11.6 / 10.6 Heating H/M/L/SL m³/min 16.1 / 13.9 / 11.5 / / 15.1 / 12.7 / / 16.9 / 14.3 / 12.7 Sound Power Cooling Medium dba Heating Medium dba Sound Pressure Cooling H/M/L/SL dba 43 / 39 / 34 / / 41 / 36 / / 42 / 37 / 34 Heating H/M/L/SL dba 42 / 38 / 33 / / 40 / 35 / / 42 / 37 / 34 1~/ V/50Hz 3MXS552E 4MXS80E, 5MXS90E Outdoor Unit 2MXS40FV1B 2MXS50FV1B 3MXS52E2V1B 4MXS68F2V1B 4MXS80E7V3B 5MXS90E7V3B Dimensions (Height x Width x Depth) mm 550x765x x765x x936x x936x x900x320 Weight kg Operation Range Cooling Min~Max CDB +10~+46 10~ ~ ~ ~46.0 Heating Min~Max CWB -10~ ~ ~ ~ ~15.5 R-410A R-410A R-410A R-410A 1~/ V/50Hz 1~/ V/50Hz 1~/230V/50Hz 1~/ V/50Hz 1~/230V/50Hz Piping connections Liquid (OD)/Gas mm 6.35 / / / / 9.52 / / 15.9 / 25 Piping Length (Maximum) m 30 (for total of each room)/ 20 (for one room) 30 (for total of each room)/ 20 (for one room) 50 (for total of each room)/ 25 (for one room) 60 (for total of each room), 25 (for one room) 70 (for total of each room)/ 25 (for one room) 75 (for total of each room)/ 25 (for one room) Max. internunit level difference m 7.5 (between indoor units) 7.5 (between indoor units) 7.5 (between indoor units) 7.5 (between indoor units) 7.5 (between indoor units) 116

101 ERYQ EKHBH/EKHBX EKSWW The Altherma air to water heat pump ERYQ AC EKHBH/EKHBX007AC EKSWW200V3 THE ALTHERMA AIR TO WATER IS TODAY S ANSWER TO THE CURRENT AND FUTURE PROBLEMS ASSOCIATED WITH CONVENTIONAL HEATING SYSTEMS, NAMELY, INCREASING PRIMARY ENERGY COSTS AND AN UNACCEPTABLY HIGH ENVIRONMENTAL IMPACT COST EFFECTIVE ALTERNATIVE TO A FOSSIL FUEL BOILER Altherma is a comparable alternative to a conventional fossil fuel boiler and optimises the inherently clean, reliable and low maintenance characteristics of heat pump technology. LOW ENERGY BILLS AND LOW CO 2 EMISSIONS Conventional fuels are becoming scarcer and ever more expensive. As these costs increase, the most attractive renewable source heating system is an air to water heat pump which, by the use of the free heat in the outside air, is at least three times more efficient when compared to a fossil fuel boiler. The result is low primary energy use and no direct CO 2 emissions. EASY TO INSTALL The compact outdoor unit can be located where convenient and requires no drilling or excavation work to collect heat. The indoor hydro-box does not require a dedicated technical room, or additional infrastructure, such as chimneys, fuel tanks or gas connections. Altherma can be connected to industry standard low temperature radiators and underfloor heating systems and can be configured for use in both new and refurbishment applications. TOTAL SOLUTION FOR YEAR ROUND COMFORT Altherma is designed to provide for your sanitary hot water needs all year round and can be selected with a cooling option for the hot summer months. The use of Daikin s advanced inverter technology and variable set-point temperature ensures accurate and stable room temperatures at all times and the lowest possible energy consumption. 121

102 The system at a glance Altherma is a split system consisting of an outdoor unit and an indoor hydro-box that can be connected to all standard low temperature radiators and underfloor heating systems. OUTDOOR UNIT The outdoor unit extracts free low temperature heat from the surrounding air and increases its temperature. Upgraded heat is then transmitted via the refrigerant circuit to the indoor hydro-box. Sanitary hot water tank () Indoor hydro-box Outdoor unit INDOOR HYDRO-BOX The indoor hydro-box transfers the heat in the refrigerant to the water circulated in the central heating radiators, underfloor heating system and sanitary hot water tank. In the combined heating & cooling version of the indoor hydro-box cooling is achieved by reducing the water temperature to 5 C and circulating it through fan coil units. The system can also provide moderate cooling via the underfloor heating system or radiators by limiting the lowest water temperature. The preparation of sanitary hot water is performed by switching the system from cooling or heating to sanitary mode. 122

103 SANITARY HOT WATER TANK (OPTIONAL) A purpose built stainless steel water tank, constructed to maintain the highest levels of energy efficiency, is available to meet sanitary hot water needs. The combination of an electric booster heater in the upper part of the tank and a heat pump heat exchanger in the lower part ensures the lowest possible energy consumption with rapid water heating. In addition, a built in function raises the water temperature to 70 C or higher at least once a week to remove any possibility of legionella growth. Typical system configuration including sanitary hot water tank and cooling SYSTEM CONTROLS System controls and the user interface are contained within the hydro-box and feature a weekly timer that enables the indoor temperature to be controlled according to user requirements. The timer is programmable on an hourly or daily basis so that temperatures can be reduced at night or during holidays and increased prior to rising in the morning or returning home. User comfort according to personal preference is thus maintained at all times. Where control over individual room temperatures and comfort levels is needed a conventional room controller should be added. 123

Wall Mounted Unit ATX-JV / ARX-JV

Wall Mounted Unit ATX-JV / ARX-JV Wall Mounted Unit ATX-JV / ARX-JV Wireless remote control as standard These popular indoor units can be mounted on virtually any type of wall, leaving space free for furniture, decoration and fittings.

More information

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Cooling only INDOOR UNITS FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Capacity cooling min~nom~max kw 1.3~2.0~2.8 1.3~2.5~3.2 1.4~3.5~4.0 1.7~4.2~5.0 1.7~5.0~5.3 1.7~6.0~6.7 2.3~7.1~8.5 Power

More information

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI PART 2 - URURU MULTI MULTI SYSTEM The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort heating, cooling humidification and fresh air ventilation. Designed primarily for two

More information

DAIKIN S URURU SARARA

DAIKIN S URURU SARARA DAIKIN S URURU SARARA FOUR TREATMENTS IN ONE UNIT COOL HEAT HUMIDIFY DEHUMIDY PURIFY VENTILATE Daikin Ururu Sarara is a unique split system reverse cycle unit, which can heat and cool, humidify and dehumidify,

More information

General CATALOGUE Daikin Airconditioning UK Ltd. new

General CATALOGUE Daikin Airconditioning UK Ltd. new General CATALOGUE 2005 Daikin Airconditioning UK Ltd Foreword In 1972, Daikin Industries Ltd, established its European head-quarters in Ostend, Belgium in answer to the rapidly growing European demand

More information

w w w. d a i k i n. e u ATXS-E

w w w. d a i k i n. e u ATXS-E Daikin air conditioners for your home WALL MOUNTED UNIT ATXS-E w w w. d a i k i n. e u Daikin s stylishly elegant wall mounted Siesta unit will grace the dining, living or bedroom of any home. Siesta will

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WLL MOUNTED UNIT www.daikineurope.com FTXG-C The UX1 has already won the Good Design ward 2003 for its modern design. This stylish wall mounted unit is available in

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Wall mounted unit SEER up to A++ Discreet, modern design Whisper quiet in operation The right indoor for the right room Heat pump system www.daikin.eu FTXS-20-25K/CTXS-15-35K

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WALL MOUNTE D UNIT w w w. d a i k i n. e u FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Wall mounted unit SEER and SCOP up to A ++ Discreet, modern design Whisper quiet in operation The right indoor for the right room www.daikin.eu FTXS20-25K/CTXS15-35K

More information

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K Designed colder climates for AIR TO AIR HEAT PUMPS FTXS-20-25K FTXS35-42-50K Optimised heating solutions down to -25 C outdoor temperatures Prestigious design Prevents winter freezing in summer homes Whisper

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WALL MOUNTED UN IT www.daikineurope.com FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series stylish

More information

Pure air. Because Daikin cares

Pure air. Because Daikin cares Pure air Because Daikin cares contents Daikin: a tradition of caring 2 Why buy an air purifier? 4 What is the Daikin streamer technology? 5 Enhanced technology 6 Features 8 Main specifications 11 Daikin:

More information

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps.   FTXS-G Full range A class energy label Air conditioners, heating & cooling for your home WALL MOUNTED UNIT air to air heat pumps www.daikin.eu FTXS-G FOR EVERY HOME, FOR EVERY ROOM unique features Full range

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN. emura DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN. 01 D5K_M027_Product Brochure.indd 1 27/10/09 11:30:28 STYLISH DESIGN TOTAL COMFORT ALL YEAR ROUND. The new

More information

Air Conditioning Systems RESIDENTIAL & COMMERCIAL CATALOGUE

Air Conditioning Systems RESIDENTIAL & COMMERCIAL CATALOGUE Air Conditioning Systes RESIDENTIAL & COMMERCIAL CATALOGUE 2008 www.daikinafrica.co Daikin Sweden A.B. Daikin Airconditioning Netherlands B.V. Daikin Airconditioning UK Ltd. Daikin Europe Dublin Office

More information

Inverter Wall Mounted

Inverter Wall Mounted PLXRHK1603 Inverter Wall Mounted FTKS-A Series COOLING ONLY What is inverter technology? Inverter system ensures faster cooling with signifi cant energy saving. Moreover, it helps to maintain consistent

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces The best of two worlds united Heating & Cooling > heating & cooling in one Quiet and discrete, Nexura offers you the best in heating and cooling, in

More information

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Remote control infrared ARC433B76 ARC433A8 ARC433B69 Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-

More information

for your home FTXS-G WALL MOUNTED UNIT

for your home FTXS-G WALL MOUNTED UNIT Air conditioners for your home WALL MOUNTED UNIT www.daikin.eu FTXS-G BUILT-IN INTELLIGENCE Pair or Multi Depending on the type of climate you want, you can choose between two models: cooling and heating

More information

Information for end users. Wall mounted units. Total comfort at home

Information for end users. Wall mounted units. Total comfort at home Information for end users Wall mounted units Total comfort at home Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant innovation in comfort,

More information

Perfect C mfort at any time of the year. A pleasant climate and pure air for living, shopping and working. Split Multi Split Sky Air

Perfect C mfort at any time of the year. A pleasant climate and pure air for living, shopping and working. Split Multi Split Sky Air Perfect C mfort at any time of the year A pleasant climate and pure air for living, shopping and working Split Multi Split Sky Air 2008 The company A climate like no other A company like no other In 2002,

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data FTXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS TM WALL-MOUNTED HEAT PUMP Up to 26.1 SEER / 11.0 HSPF / 15.8 EER INVERTER, VARIABLE-SPEED COMPRESSOR QUATERNITY Series TM Discreet wall-mounted unit

More information

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN Energy efficient heating and cooling solutions for your home CHOOSING THE RIGHT Split System FOR YOUR HOME... WALL MOUNTED UNITS. Reverse cycle (heating

More information

Wall mounted units. Total comfort at home

Wall mounted units. Total comfort at home Wall mounted units Total comfort at home Why choose Daikin? Daikin is a world leader in air conditioning and heating. So no matter what your needs, you will find the ideal solution in our wide range of

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN Energy efficient heating and cooling solutions for your home Making the Right Choice : Split Systems. YEAR ROUND Comfort FOR YOUR FAMILY Every house

More information

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home HEAT PUMPS BY DAIKIN Energy efficient heating and cooling solutions for your home DAI0096_HeatPumpBrochure_v3.indd 1 18/05/12 5:09 PM Year round comfort for your family Heat pumps do much more than heat

More information

for your home FTYN-GX FT(Y)N-F

for your home   FTYN-GX FT(Y)N-F Air conditioners for your home W A L L M O U N T E D U N I T www.daikin.eu FTYN-GX FT(Y)N-F FOR EVERY HOME, FOR EVERY ROOM EVERY DAY, MORE AND MORE PEOPLE ARE MAKING A CONSCIOUS EFFORT TO RAISE THEIR QUALITY

More information

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN Energy efficient heating and cooling solutions for your home Making the Right Choice : Split Systems. YEAR ROUND Comfort FOR YOUR FAMILY Every house

More information

EDAU Air Purifiers. Engineering Data MC70LPVM

EDAU Air Purifiers. Engineering Data MC70LPVM EDAU01-0713 Air Purifiers Engineering Data TABLE OF CONTENTS 1 Features.......................... 2 Key Features....................... 2 Streamer Technology................. 2 Clean Air..........................

More information

EPCE General. Catalogue. Air Conditioning Systems

EPCE General. Catalogue. Air Conditioning Systems EPCE2004-2 General Catalogue Air Conditioning Systems Foreword In 1972, Daikin Industries Ltd, established its European headquarters in Ostend, Belgium in answer to the rapidly growing European demand

More information

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER DON'T With the COMPROMISE emerging trend ON HEALTH towards AND double COMFORT. storey homes BREATHE on smaller EASY blocks, WITH DAIKIN S the AIR compact

More information

EPCE2004-2B. General. General Catalogue Catalogue. Air Conditioning Systems

EPCE2004-2B. General. General Catalogue Catalogue. Air Conditioning Systems EPCE2004-2B General Catalogue 2004 General Catalogue Air Conditioning Systems Foreword In 1972, Daikin Industries Ltd, established its European headquarters in Ostend, Belgium in answer to the rapidly

More information

heating, air conditioning, applied systems, refrigeration GENERAL CATALOGUE 2008

heating, air conditioning, applied systems, refrigeration GENERAL CATALOGUE 2008 heating, air conditioning, applied systes, refrigeration GENERAL CATALOGUE 2008 www.daikin.eu Foreword THE LEADER IN MANUFACTURING QUALITY AND CUSTOMER SERVICE Since our establishent in Ostend (Belgiu)

More information

Ceiling Suspended Unit

Ceiling Suspended Unit Ceiling Suspended Unit FHQ-B / RZQ-D(BW1) Wired remote control (standard) Wireless remote control (optional) Ceiling suspended units are the ideal solution for rooms without false ceilings. These indoor

More information

air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS

air conditioners for your home, shops, restaurants, offices, small hotels   MULTI MODEL APPLICATIONS air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture

More information

PHOTOCATALYTIC AIR CLEANER

PHOTOCATALYTIC AIR CLEANER EPCE03-16 PHOTOCATALYTIC AIR CLEANER MC704VM Clean air is essential for a comfortable environment Table of contents 4 01 Antibacterial 5 02 Photocatalytic deodorising power 6 03 Impressive air flow 3 7

More information

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT Air Purifiers Cleaner fresher healthier air A Daikin air purifier improves the quality of your air indoors,

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Reduced power consumption thanks to DC inverter fan

More information

Daikin air conditioners for shops, restaurant and offices

Daikin air conditioners for shops, restaurant and offices Daikin air conditioners for shops, restaurant and offices ROUNDFLOW CEILING MOUNTED CASSETTE w w w. d a i k i n. e u FCQH-C The new Daikin Sky Air Roundflow Cassette: Daikin has renewed its Sky Air ceiling

More information

BENEFIT FROM LOWER FUEL COSTS.

BENEFIT FROM LOWER FUEL COSTS. TODAY, MORE AND MORE PEOPLE ARE MAKING A VERY CONSCIOUS CHOICE TO ENJOY THE COMFORT OF AIR CONDITIONING IN THEIR HOME. IT IS WIDELY RECOGNISED THAT BALANCED AIR CONDITIONING HAS A TANGIBLE EFFECT ON THE

More information

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air Indoor Units R-40A FTXS-G2VB

More information

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal FTXB20-35C Rear side 770 Right side Standard location of holes in the wall 16 770 549 101 172 6 Left side Front panel fixing screws Including mounting plate 216 198 General Rating Nameplate 41.3 54.5 Hole

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling»» Up to five indoor units» on one outdoor unit M u l t i m o d e l a p p l i c a t i o n»» Individual control» per room»» Combination» of different indoor models»» Inverter

More information

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Information for end users. Floor standing units. 24/7 comfort in a contemporary package Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant

More information

AIR CONDITIONERS, HEATING & COOLING for your home

AIR CONDITIONERS, HEATING & COOLING for your home AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides

More information

for the retail market, hotels, restaurants and offices

for the retail market, hotels, restaurants and offices Air conditioners, HEATING & COOLING for the retail market, hotels, restaurants and offices INVERTER DRIVEN CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FBQ-C INtelligent unit, neatly concealed

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling Ceiling Suspended Cassette»» Energy label:» Up to class A»» Heat pump system»» Seasonal inverter technology»» The ideal solution» for larger rooms»» Can be installed

More information

Air Conditioners. Technical Data FTXS-G

Air Conditioners. Technical Data FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE

More information

SHOPS, RESTA URA NTS, OFFICES, HOTELS,

SHOPS, RESTA URA NTS, OFFICES, HOTELS, AIR CONDITIONERS FOR YOUR HOME, A P A RTMENTS, SHOPS, RESTA URA NTS, OFFICES, HOTELS, Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW Air Conditioning Technical Data Wall mounted unit EEDEN2-00 FTXG-JW Indoor Unit Wall mounted unit FTXG-JW TABLE OF CONTENTS FTXG-JW Features.............................................................

More information

Pure air. because Daikin cares

Pure air. because Daikin cares Pure air because Daikin cares MCK75J MC70L Why choose a Daikin air purifier? 3 Increased air quality with the Daikin streamer technology 4 Air purification and humidification 8 Additional comfort 10 User-friendly

More information

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS 1.5-3 TON, 2-4 ZONE SYSTEMS UP TO 18.9 SEER / UP TO 12.5 HSPF / UP TO 12.7 EER VARIABLE-SPEED COMPRESSOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

More information

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S air conditioners for your home, shops, restaurants, offices, small hotels M U L T I M O D E L A P P L I C A T I O N S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in

More information

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S air conditioners for your home, apartments, shops, restaurants, offices, hotels, S U P E R M U L T I P L U S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful

More information

URURU SARARA. Total. comfort solution

URURU SARARA. Total. comfort solution URURU SARARA Total comfort solution The new and unique ruru Sarara 5 air treatment techniques in 1 system Lowest environmental impact Perfect comfort Heating a room in winter tends to dry the air, which

More information

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort Daikin Sensira R-32 Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more

More information

Daikin UK Product Catalogue. 1 st April your comfort. our world.

Daikin UK Product Catalogue. 1 st April your comfort. our world. Daikin UK Product Catalogue 1 st April 2010 your comfort. our world. FOReword Daikin the leader in manufacturing quality and customer service Daikin was founded in 1924 in Osaka, Japan. The company we

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 CTXS-K Indoor Unit Wall mounted unit CTXS-K TABLE OF CONTENTS CTXS-K Features.............................................................

More information

PCR0709A. Options. Indoor unit

PCR0709A. Options. Indoor unit Indoor unit No. 1 2 3 4 Item 5-room centralised controller Wiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying

More information

Air Purifiers. Technical Data MC70L

Air Purifiers. Technical Data MC70L Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Single Unit MC70L TABLE OF CONTENTS MC70L Features.............................................................

More information

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping Heating & Cooling OPTIMIZED FOR SEASONAL EFFICIENCY INDOOR UNIT FCQG71E FCQG100E FCQG125E FCQG140E Cooling capacity Nom. kw 7.1 3 10.0 3 12.0 14.0 3 Heating capacity Nom. kw 8.0 4 11.2 4-16 4 Power input

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

for your home FLXS-B Flexi type unit air to air heat pumps

for your home FLXS-B Flexi type unit   air to air heat pumps Air conditioners, HEATING & COOLING for your home Flexi type unit air to air heat pumps www.daikin.eu FLXS-B TOP CLASS, MADE FOR A LONG FUTURE The importance of well-being and pleasure is increasing in

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN Energy efficient heating and cooling solutions for your home YEAR ROUND Comfort FOR YOUR FAMILY Air conditioning does much more than heat and cool

More information

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Information for end users. Floor standing units. 24/7 comfort in a contemporary package Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant

More information

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for shops,restaurants and offices Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing

More information

The Comfort and Luxury You Deserve

The Comfort and Luxury You Deserve PCRSG0716C The Comfort and Luxury You Deserve Multi-Split Type Air Conditioners With DC Inverter and Swing Compressor Cooling Only [50 Hz] Air condition your entire home with a single outdoor unit. If

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling W a l l M o u n t e d U n i t For high ambient temperatures up to 52 C 50 Hz Heat pump system Energy efficient Dehumification without a drop in temperature Same comfort

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e F U L L R A N G E A C L A S S E N E R G Y L A B E L Seasonal efficiency, optimized for all seasons Heat pump system Round flow principle:

More information

Up to SEER 26.1 Wall Mount Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump Up to SEER 26.1 Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s Quaternity system incorporates technological innovations that deliver features and benefits superior to traditional mini split systems.

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling Ceiling suspended unit Energy label:» Up to class A Seasonal efficiency, optimized for all seasons Heat pump system Installation possible in new and existing buildings

More information

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air technical data FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order

More information

VRV IV S-series heat pump

VRV IV S-series heat pump VRV IV S-series heat pump The most compact VRV Most compact unit on the market 3mm high & kg Control systems Indoor units VRV type indoor units Residential type indoor units (such as Daikin Emura) Air

More information

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only KE Series SEER 14+ Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s SEER 14+ single split systems feature streamlined, wall-mounted indoor units paired with quietly compact outdoor

More information

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates Optimised for heating Designed for living 4 Main features 6 Innovation in action 8 Indoor units 12 Wall mounted units Daikin Emura FTXG-LW/S

More information

SUPERB TECHNOLOGY FOR SUPERB INTERIORS

SUPERB TECHNOLOGY FOR SUPERB INTERIORS SUPERB TECHNOLOGY FOR SUPERB INTERIORS Emura high end residential applications.indd 1 15/07/2014 12:04:26 DISCOVER A NEW WORLD OF INTERIOR DESIGN There s no mystery about it: we create fantastic interiors

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e Energy label:» Up to class A Heat pump system Seasonal inverter technology Round flow 360 air discharge Fits flush» into a false ceiling

More information

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates Optimised for heating Designed for living 4 Main features 6 Innovation in action 8 Indoor units 12 Wall mounted units Daikin Emura FTXG-LW/S

More information

emura Form. function. redefined.

emura Form. function. redefined. emura Form. function. redefined. IT S ALL ABOUT DESIGN award winning design Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded with several prestigious design awards: if Product

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r u n i t - m u l t i m o d e l E E D E N 2-0 0 MXS-K TABLE OF CONTENTS MXS-K Features............................................................. 2 2 Specifications.......................................................

More information

LV Series. SEER 20+ Wall Mount Heat Pump

LV Series. SEER 20+ Wall Mount Heat Pump LV Series SEER 20+ Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s SEER 20+ single split systems feature wall mounted units with a sophisticated appearance and a flat panel design. Packed with high

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3 Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-J3 TALE OF CONTENTS FTX-J3 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling»» Up to five indoor units on one outdoor unit Multi model application»» Individual control per room»» Combination of different indoor models»» Inverter controlled www.daikin.eu

More information

where innovation meets creativity

where innovation meets creativity where innovation meets creativity Stylish wall mounted unit Designed for comfort With more than 90 years of experience in air conditioning and climate control solutions, Daikin combines the best of design

More information

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air technical data FT(Y)S-B Wall Mounted Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

The Comfort and Luxury You Deserve

The Comfort and Luxury You Deserve PCRAU0644C The Comfort and Luxury You Deserve Multi-Split Type Air Conditioners E series With DC Inverter and Swing Compressor Only & Heat Pump [50 Hz] Air condition your home with a single outdoor unit.

More information

Daikin air conditioners for your home, shops, restaurants and offices

Daikin air conditioners for your home, shops, restaurants and offices Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction

More information

HEATING AND COOLING SOLUTIONS SPLIT HEAT PUMPS PCSPNZ0517

HEATING AND COOLING SOLUTIONS SPLIT HEAT PUMPS PCSPNZ0517 HEATING AND COOLING SOLUTIONS SPLIT HEAT PUMPS PCSPNZ0517 THE BEST AIR ANYWHERE At Daikin, we're not just in the business of heat pumps. We're in the business of human comfort. Our passion for designing

More information

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz]

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz] Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Your perfect atmosphere

Your perfect atmosphere Information for end users: top efficiency and comfort range Our mission: Your perfect atmosphere 2 FTXZ-N, p. 12 FTXJ-MS, p. 10 Get ready The evolution of pure comfort Discover the next generation of comfort

More information

Air Conditioning Systems

Air Conditioning Systems Air Conditioning Systems COMMERCIAL CATALOGUE 2012 w w w. d a i k i n a f r i c a. c o m Make your world a better place AIR CONDITIONING REFRIGERATION HEATING APPLIED SYSTEMS Our mission, and the essence

More information