60 C water temperature ensures thermal disinfection during hot water production

Size: px
Start display at page:

Download "60 C water temperature ensures thermal disinfection during hot water production"

Transcription

1 Product Catalog - Product Sheets Work smarter and get the complete overview of Danfoss Systems & Water Heaters for domestic hot water and district heating applications 60 C water temperature ensures thermal disinfection during hot water production

2 Index 3 Termix One Solar 6 Termix Novi 8 Akva Vita II 10 Akva Lux II GW 12 ThermoDual 14 Termix One-B with complete insulation 16 ThermoDual 26 Akva Therm II LV 28 Termix One-B 30 Akva Lux II, fully insulated 32 Termix One Solar Light 34 ThermoClean 42 ThermoDual CM 46 ThermoDual FLS 50 ThermoClean

3 Substations for multi-family and single-family homes Termix One Solar Termix Novi Akva Vita II Akva Lux II GW ThermoDual Termix One-B with complete insulation ThermoDual Akva Therm II LV Termix One-B Akva Lux II, fully insulated Termix One Solar Light ThermoClean ThermoDual CM ThermoDual FLS

4 Termix One Solar Domestic hot water module for flats, single-family houses and apartment buildings with up to 10 apartments Domestic hot water module with heat exchanger and thermostatic control. Designed for wall-mounting. Application The Termix One Solar is an instantaneous water heater, featuring superb heat extraction and high performance. The Termix One Solar is applicable for heating systems with buffer accumulators, solar systems or for other heat sources, where a very low return temperature is preferred. The water heater is available in three sizes, either for 1 apartment, for 1-4 apartments or for 5 up to 10 apartments. The large heat exchanger cools out the water in the primary return line very efficiently, thereby creating a very good operation economy. A flow switch in cold water mains is controlling the primary heating pump. An optional circulation pump together with a thermostat can maintain the circulating temperature at a desired temperature. Domestic hot water () The domestic hot water is prepared in the heat exchanger and the temperature is regulated with a thermostatic control valve. The patented sensor accelerator accelerates the closing of the thermostatic control valve and protects the heat exchanger against overheating and lime scale formation. The sensor accelerator and the thermostatic control valve also works as a bypass keeping the heat exchanger and supply line warm. This shortens the waiting periods. The sensor accelerator helps to ensure a stable hot water temperature by varying loads, flow temperatures and differential pressure without the need for readjusting the valve. There is no additional pressure loss on the secondary side of the heat exchanger with a thermostatic control. Therefore this type of regulation can be used by low pressure in the cold water mains. Options The water heater can be supplied with built in non-return valve and safety valve mounted in the cold water supply. Construction All pipes are made of stainless steel. The connections are made by nuts and gaskets. The Termix One Solar is delivered with an attractive steel grey cover in modern design, emphasising the high level of quality and comfort which characterises this product. FEATURES AND BENEFITS Domestic hot water module regulation with an accelerated thermostatic control Capacity: Up to 90 kw on in sufficient quantity Operates independent of differential pressure and flow temperature Minimum space required for installation Pipes and plate heat exchanger made of stainless steel Minimized risk of lime scale and bacteria formation VC.LC.G4.02 Danfoss 05/2012

5 Termix One Solar Circuit diagram - example BT supply BT return DCW Termix One Solar O Termix Sensor Accelerator 39 Connection closed B Plate heat exchanger 45 Flow switch 1 Ball valve 48 Air vent, manual 2 Single check valve 63 Sieve 7 Thermostatic valve 13 Charging pump 35 Ball valve / non-return valve BT supply BT return Cirk. DCW Termix One Solar with circulation O Termix Sensor Accelerator B Plate heat exchanger 1 Ball valve 2 Single check valve 4 Safety valve 7 Thermostatic valve 11 Circulation pump 13 Charging pump 24 Delivered loose with unit 35 Ball valve / non-return valve 39 Connection closed 45 Flow switch 48 Air vent, manual 63 Sieve Technical parameters: Nominal pressure: PN 16 DH supply temperature: T max = 120 C DCW static pressure: p min = 0,5 bar Brazing material (HEX): Copper Weight incl. cover: Cover: 20 kg (incl. packing) Grey-lacquered steel sheet Dimensions (mm): Without cover: H 760 B 312 T 155 With cover: H 760 B 315 T 165 Without cover, with circulation: H 935 B 410 T 150 With circulation: Without cover: H 960 B 400 T 190 With cover: H 960 B 400 T 190 Seen from above Wall Connections: 1 Domestic cold water (DCW) 2 Domestic hot water () 3 Buffer tank (BT) supply 4 Buffer tank (BT) return 5 Circulation Connections sizes: All connections: G ¾ (int. thread) : Capacity examples, 10 C/50 C Substation type Type 1 w/avtb 15 1 household Type 3 w/avtb 20 5 to 10* households Capacity kw Supply flow C Return flow C Pressure loss kpa Flow rate Secondary l/h Substation type Capacity kw Supply flow C Return flow C Pressure loss kpa Flow rate Secondary l/h Type w/avtb up to 4 households * Capacity for 10 households at 70 C DH flow temperature Gemina Termix A/S Member of the Danfoss Group Navervej DK-7451 Sunds Denmark Tel.: Fax: mail@termix.dk VC.LC.G4.02 Danfoss 05/2012 DEN-SMT/PL

6 Termix Novi Instantaneous water heater for flats, single-family houses and small apartment buildings with up to 4 flats. Instantaneous water heater with heat exchanger and flow compensated temperature controller. Designed for wall-mounting. Application The Termix Novi is an instantaneous water heater featuring superb heat extraction and high performance. The Termix Novi is suitable for flats, single-family houses as well as for small apartment buildings. The water heater is available in two sizes, either for 1 apartment, or up to 4 apartments. The Termix Novi is applicable for decentralized heating systems as well as for district heating networks with summer operation at low temperatures or with changes in differential pressure. The heat exchanger in Termix Novi cools the district heating water very efficiently, thereby creating a very good operation economy. Domestic hot water () The domestic hot water is prepared in the heat exchanger and the temperature is regulated by a flow-compensated temperature controller with a integrated differential pressure controller. The Danfoss IHPT valve ensures a stable hot water temperature by varying differential pressure without the need for readjusting the valve. This protects the heat exchanger against overheating and lime scale formation. Furthermore the IHPT valve has an integrated idle temperature controller, which keeps the house supply line warm. This shortens the waiting periods during summer when the heating system is in reduced operation, which is ideal where high comfort is requested. Options The water heater can be supplied with a built in non-return valve and safety valve mounted in the cold water supply. The water heater can also be supplied with a thermostatic circulation valve and a non-return and pressure equalizer (GTU). Construction All pipes are made of stainless steel. The connections are made by nuts and gaskets. The Termix Novi is delivered with an attractive grey full insulation in modern design, emphasising the high level of quality and comfort which characterises this product. FEATURES AND BENEFITS Instantaneous water heater regulation with an accelerated thermostatic control Capacity: up to 61 kw in sufficient quantity Operates independently of differential pressure and flow temperature Minimum space required for installation Pipes and plate heat exchanger made of stainless steel Minimized risk of lime scale and bacteria formation Optimum temperature regulation up to DH supply temperature 100 C VL.GE.J3.02 Danfoss 05/2012

7 Termix Novi Circuit diagram example DH supply 72 B Water heater 9 Strainer 72 IHPT CWM 9 DH return Technical parameters: Nominal pressure: PN 16 DH supply temperature: T max = 120 C DCW static pressure: p min = 1,0 bar Brazing material (HEX): Copper Weight incl. cover: 7-9 kg (incl. packing) Cover: Grey lacquered steel Dimensions (mm): With insulation: H 432 x W 300 x D 155 With cover: H 442 x W 315 x D 165 Connections: 1 Domestic cold water (DCW) 2 Domestic hot water () 3 District heating flow (DH) 4 District heating return (DH) Wall Connections sizes: DH + DCW + : G ¾ (ext. thread) Options: Booster pump (increases DH flow) Grey-lacquered steel cover Safety valve and non-return valve (10 bar) Safety valve with thermostatic circulation set Thermostatic circulation set Non-return and pressure equalizer (GTU) : Capacity examples : Capacity examples Capacity Substation type kw Technical data table Novi Type 1 Supply flow C Return flow C C Pressure loss kpa Tap load l/min 32, / ,3 41, / , / , / , / , / , / , / ,0 Substation type Novi Type 2 Capacity kw Supply flow C Return flow C Gemina Termix A/S Member of the Danfoss Group Navervej DK-7451 Sunds Denmark Tel.: Fax: mail@termix.dk C Pressure loss Pr i m a r y kpa Tap load l/min 32, / , / , / ,7 48, / , / , / , / , / , / ,3 58, / ,2 VL.GE.J3.02 Danfoss 05/2012 DEN-SMT-PL

8 Akva Vita II Instantaneous water heater for single-family houses and flats Pressure controlled instantaneous water heater with heat exchanger. Unique temperature control with e save TM function and cold heat exchanger during standby. Application The Akva Vita II is an instantaneous water heater featuring high performance and simple operation. It is especially suitable for single-family houses and for systems with a similar domestic hot water requirement. The Akva Vita II can be used directly on district heating networks with a differential pressure of max. 2.5 bar. Construction The Akva Vita II water heater is prefabricated with a brazed, highly efficient Danfoss plate heat exchanger for domestic hot water production, a domestic hot water controller Danfoss PM2+P, as well as a Danfoss FJVR thermostat for control of the bypass/ circulation temperature. All pipes are made of stainless steel and the connections are made by nuts and gaskets. As an option and if approved by local regulations the water heater can be supplied with a Danfoss AVE expansion unit to avoid having to establish a discharge pipe. Design The Akva Vita II is designed for wallmounting and the design emphasizes a user-friendly placement of the controllers. The Akva Vita II can be supplied with a brushed or white-lacquered stainless steel cover in an elegant and modern design. VL.GP.J1.02 Danfoss 10/2012 Bypass (thermostatic circulation) The water heater is supplied with a thermostatically controlled bypass, which ensures that hot water is produced immediately, when tapping starts. The bypass temperature is set with due consideration of the best possible comfort and economy. Domestic hot water circulation The water heater is prepared for domestic hot water circulation. If the household piping includes hot water recirculation the water heater must be connected to the hot water recirculation system and a circulation pump and a non-return valve must be mounted on the circulation pipe and a safety valve must be mounted in the DCW inlet. The pump must be installed so that it pumps towards the water heater. Domestic hot water circulation ensures that hot water is available at the tapping point without waiting time and waste of water. The circulation temperature is set independently of the set temperature. This ensures the best possible comfort, very low standby losses and thus a very good district heating economy. Please note that Akva Vita II with AVE expansion unit should not be used on systems with domestic hot water recirculation. Heat exchanger for heating The water heater is based on a brazed, highly efficient plate heat exchanger type XB 06H-1 26, which is controlled by a pressure controlled controller, Danfoss PM+P with integrated differential pressure controller and e save TM function, which ensures that the heat exchanger is cold during standby. After completion of the tapping process, the controller immediately blocks the district heating flow, to avoid standby losses and to protect the heat exchanger from the formation of lime scale and growth of bacteria. The heat exchanger is cold during standby, so the heat loss is very low. The integrated differential pressure controller compensates for variations in supply temperature and varying differential pressure and thereby ensures a constant hot water temperature at all times. Service and maintenance The water heater is very service-friendly and easy to install. It is mounted on the wall and as all pipes are placed in pipe bracket distance, it is possible to establish a nice piping. Features and benefits COLD heat exchanger during standby, - no standby losses controller PM2+P with integrated differential pressure controller and e save TM function Pipes and heat exchanger made of stainless steeel, connections with EPDM gaskets. Minimized risk of lime scale and bacteria formation, no Legionella Capacity: 35 kw

9 Akva Vita II Circuit diagram Example 1. Danfoss copper brazed plate heat exchanger in stainless steel AISI 316, type XB 06H Domestic hot water controller type Danfoss PM2+P. 1 circ. Bypass Bypass/circulation thermostat Danfoss FJVR. 4. Connection of capillary tube from Danfoss FJVR acting as bypass thermostat (standard function). 5. Connection of capillary tube from Danfoss FJVR acting as circulation thermostat ( recirculation). 6. Connection piece for circulation pipe, if any. DCW DH Supply DH. return Note: Circulation set is not part of the delivery and must be ordered separately and mounted on site. Design specifications: Nominal pressure (prim/sec.): PN 16 / PN 16 Max. supply temperature: 120 ºC DCW static pressure: p min = 2.0 bar Min. P: See capacity examples Chloride compounds: Max. 300 mg/l Connections: 1. Domesctic cold water (DCW) 2. Domestic hot water () 3. District heating (DH) supply 4. District heating (DH) return 5. Circulation (not part of dly) Weight incl. cover: (incl. packing) Cover: Dimensions (mm): Without cover: With cover: Connections sizes: DH, DCW, : Circulation: 9 kg Brushed steel H420xW250xD150 H420xW255xD160 R ½ ET (ext. thread) R ½ ET (ext. thread)) (5) Top view Code No s: Akva Vita II with heat exchanger type: Cover: Code no.: XB 06H-1 26 w/o 004U8376 brushed 004U8378 XB 06H AVE brushed 004U8379 Options Cover, brushed stainless steel H397xW225 x D160 mm Circulation set for mounting on site Safety valve set AVE expansion unit* * requires local approval Varmt vand: Ydelseseksempler ved 10 C / 45 C Capacity kw Supply flow C Return flow C tap load l/min Pressure loss* bar Flow rate l/h *) Stated pressure loss values are complete, incl. pipes, heat exchanger and valves. Danfoss Redan A/S District Heating Omega 7 DK-8382 Hinnerup Tel.: Fax: redan@danfoss.com VL.GP.J1.02 Danfoss 10/2012 DKDHR

10 Akva Lux II GW Instantaneous water heater for low-temperature district heating Thermostatic and pressure controlled instantaneous water heater with heat exchanger. Unique temperature control with e save TM function and cold heat exchanger during standby. Application Akva Lux II GW is an instantaneous water heater featuring high performance. It meets the future energy demands for low energy consumption and very low standby heat losses. It is especially suitable for large villas with for instance several bathrooms or jacuzzi and for the large family, for which an exceptionally large amount of water is required. The Akva Lux II GW is also very suitable for small apartment houses with 2-4 apartments. Construction The Akva Lux II GW water heater is prefabricated with a gasketed, highly efficient plate heat exchanger for domestic hot water production, a domestic hot water controller Danfoss PTC2+P, as well as a Danfoss FJVR thermostat for control of the bypass/circulation temperature. A circulation set, a safety set or, if approved by local regulations, a Danfoss AVE expansion unit to avoid having to establish a discharge pipe, is available as optional equipment. Design The Akva Lux II GW is designed for wallmounting and the design emphasizes a userfriendly placement of the controllers. The Akva Lux II GW can be supplied with a whitelacquered cover in modern design. Bypass (thermostatic circulation) The water heater is supplied with a thermostatically controlled bypass, which ensures VL.GP.H1.02 Danfoss 10/2012 that hot water is produced immediately, when tapping starts. The bypass temperature is set with due consideration of the best possible comfort and economy. Domestic hot water recirculation The water heater is prepared for domestic hot water circulation. If the household piping includes hot water recirculation the water heater must be connected to the hot water recirculation system and aa circulation pump and a non-return valve must be mounted on the circulation pipe and a safety valve must be mounted in the DCW inlet. The pump must be installed so that it pumps towards the water heater. Domestic hot water recirculation ensures that hot water is available at the tapping point without waiting time and waste of water. The circulation temperature is set independently of the set temperature. This ensures the best possible comfort, very low standby losses and thus a very good district heating economy. Please note that Akva Lux II with AVE expansion unit should not be used on systems with domestic hot water recirculation. Heat exchanger for heating The water heater is based on a highly efficient gasketed plate heat exchanger, which is controlled by a thermostatic and pressure controlled controller, Danfoss PTC2+P with integrated differential pressure controller and e save TM function, which ensures that the heat exchanger is cold during standby. After completion of the tapping process, the controller immediately blocks the district heating flow, to avoid standby losses and to protect the heat exchanger from the formation of lime scale and growth of bacteria. The heat exchanger is cold during standby, so the heat loss is very low. The integrated differential pressure controller compensates for variations in supply temperature and varying differential pressure and thereby ensures a constant hot water temperature at all times. Service and maintenance The water heater is very service-friendly and easy to install. It is mounted on the wall and as all pipes are placed in pipe bracket distance, it is possible to establish a nice piping. FEATURES AND BENEFITS Prepared for low-temperature district heating Very low heat losses Cold heat exchanger during standby, - no standby losses controller PTC2+P with integrated differential pressure controller and e save TM function Pipes and heat exchanger made of stainless steel, connections with EPDM gaskets. Minimized risk of lime scale and bacteria formation Capacity: up to 53 kw

11 Akva Lux II GW Circuit diagram Example circ Gasketed plate heat exchanger in stainless steel, type U141RH 2. Domestic hot water controller Danfoss PTC2+P with e save TM function (= cold heat exchanger during standby). 3. By-pass/circulation thermostat Danfoss FJVR. 4. Connection of capillary tube from Danfoss FJVR acting as by-pass (standard function) Bypass 4 3 circulation: 5. Connection of capillary tube from Danfoss FJVR acting as circulation thermostat. 6. Connection of circulation hose. Circulation set for control change from bypass to recirculation is not part of the delivery and must be ordered seperately. DCW DH Supply DH Return (Please note that AVE must not be used on systems with circulation. For systems with recirculation the water heater must be supplied with circulation pump, non-return valve and safety valve mounted in the cold water supply). Design specifications: Nominal pressure (prim/sec.): PN 16 / PN 16 Max. supply temperature: 120 ºC DCW static pressure: p min = 2.0 bar Min. P: See capacity examples Chloride compounds: Max. 300 mg/l Connections: 1. Domesctic cold water (DCW) 2. Domestic hot water () 3. District heating (DH) supply 4. District heating (DH) return 5. Circulation (not part of dly) Weight incl. cover: (incl. packing) Cover: Dimensions (mm): Without cover: With cover: Connections sizes: DH, DCW, : Circulation: 17 kg White-lacquered steel H463xW280xD230 H463xW300xD240 G ¾ ET (ext. thread) R ½ ET (ext. thread) (5) (5) Wall Code No s: Akva Lux II GW water heater with heat exchanger U141RH Cover Code no.: w/o cover 004U8366 w. cover 004U8367 Options: Cover H 430 x W 300 x D 240 mm AVE pressure equalizer * Circulation set for mounting on site Safety valve set * requires local approval Top view Varmt vand: Ydelseseksempler ved 10 C/45 C Capacity kw Plate heat exchanger Supply flow primary C Return flow primary C tap load l/min Danfoss Redan A/S District Energy Omega 7 DK-8382 Hinnerup Tel.: Fax: redan@danfoss.com Pressure loss* bar 32,3 U141RH ,3 U141RH ,0 U141RH ,0 U141RH *) Stated pressure loss values are complete, incl. pipes. heat exchanger and valves Flow rate l/h VL.GP.H1.02 Danfoss 10/2012 DKDHR

12 ThermoDual Domestic hot water charging system for hospitals, hotels, restaurants, sport centres as well as industrial buildings and dwelling houses Domestic hot water charging system with heat exchanger and optional self-acting or electronic controls Application ThermoDual is a compact and effective domestic hot water () charging system. It optimally combines the system of storage water heater and instantaneous water heating system. The ThermoDual system is suitable for hospitals, hotels, restaurants, sport centres as well as industrial buildings and dwelling houses, where the constant temperature even during peak consumption periods is needed. ThermoDual can be supplied from local and district heating systems, low-temperature or condensing boilers, boiler systems as well as solar, process and waste heat systems. The system is available in two different types with integrated storage tank and integrated brazed ( S) or gasketed ( GS) plate heat exchanger. Domestic hot water () The ThermoDual system can be delivered with self-acting or electronic controller for controlling of the charging temperature and the temperature in storage tank. It ensures the constant flow and temperature even during peak consumption periods. The system operates in three operation modes: a load low operation, a peak load operation and a charging operation (no consumption). Domestic hot water circulation ThermoDual is supplied with connection for circulation. The connection pipe of circulation is placed directly on the storage tank or in the cold water side (between storage tank and heat exchanger). Options The system can be combined with a second or multiple storage tanks for optimum tailoring to on-site conditions. Construction The storage tank and plate heat exchanger are made of stainless steel. The ThermoDual system is delivered as a set of storage tank and charging unit with all required connection parts. The charging unit can be easily assembled with storage tank through attached premounted fitting set. FEATURES AND BENEFITS charging system Electronic or self - acting control of temperature Performance index NL: 3-87 / Connected load: / kw 1 Constant temperature Compact design Easy installation 1 ThermoDual S / GS VL.KR.G3.02 Danfoss 12/2012

13 ThermoDual Circuit diagram - example 4 5 CVS/CVE HEL LPU TC SFV DTA 1 3 TC shut off device balancing valve sensor (direct, cable / universal, surface) thermometer drain / air vent (on site / by customer) DTA Domestic buffer tank HEL HEX charging / load LPU Charging pump / load SFV Safety valve CVE Control valve electrical (accessory) CVS Control valve self-acting (accessory) Connections: 1 Domestic water cold 2 Domestic water hot 3 Circulation (options) 4 Heating supply 5 Heating return 37 Domestic water load Technical parameters: Type S Nominal pressure: PN 16 (25) 2 DH supply temp.: T max = 100 (150) 2 C Type GS Nominal pressure: PN 3 DH supply temp.: T max = 110 C 2 Available on request. Options: Stainless steel storage tank, series SE, capacity liters Tube and shell heat exchanger, stainless steel, series SHR VAA -adequate bronze or stainless steel charging pump Balancing valve Stainless steel sensor pockets Self-acting control valves as 2-way valve, 3-way mixing valve, or 3-way diverting valve, with thread or flange Control and safety thermostats, storage tank thermometer Additional storage tank : Capacity examples Type temperatures prim./sec. C Performance index NL 3 Connected load kw top delivery l/10 min l/h Input W 4 H mm Dimensions W mm D mm Net weight kg S >25/10-> / max /2 -GS >35/10-> Performance index NL acc. to DIN 4708 in relation to a storage tank water temperature of 60 C. 4 Charging pump; A.C. 1 ~ 230 V / 50 Hz; thermal motor overload protection or motor protection by integrated thermo switch. Connections 1, 2 3 4, 5 3/4 1 3/4 1 DN 20 (26,9 mm) G 11/4 Danfoss GmbH Fernwärme- und Regelungstechnik Kolumbusstraße 14 D Hamburg Tel.: +49 (0) 40/ Fax: +49 (0) 69/ info-hh@danfoss.com VL.KR.G3.02 Danfoss 12/2012 DEN-SMT/PL

14 Termix One-B with complete insulation Instantaneous water heater for flats, single-family houses and small apartment buildings with up to 4 flats Instantaneous water heater with heat exchanger and thermostatic control. Designed for wall-mounting. Application The Termix One is an instantaneous water heater featuring superb heat extraction and high performance. The Termix One is suitable for flats, single-family houses as well as for small apartment buildings with up to 4 apartments. The water heater is available in two sizes, either for 1 apartment or for 1 4 apartments. The Termix One is applicable for decentralized heating systems as well as for district heating networks with summer operation at low temperatures or changes in differential pressure. The Termix One heat exchanger cools the district heating water very efficiently, thereby creating a very good operation economy. Domestic hot water () The domestic hot water is prepared in the heat exchanger and the temperature is regulated with a thermostatic control valve. The patented sensor accelerator accelerates the closing of the Danfoss AVTB valve and protects the heat exchanger against overheating and lime scale formation. The sensor accelerator and AVTB valve also works as a bypass keeping the house supply line warm. This shortens the waiting periods during summer when the heating system is in reduced operation. The sensor accelerator helps to ensure a stable hot water temperature by varying loads, flow temperatures and differential pressure without the need for readjusting the valve. There is no additional pressure loss on the secondary side of the heat exchanger with a thermostatic control. Therefore this type of regulation can be used by low pressure on the in the cold water mains. Construction All pipes are made of stainless steel. The connections are made by nuts and gaskets. The Termix One comes with a complete fully insulated cover thus minimizing the heat loss both during tapping of domestic hot water but also in standby mode. FEATURES AND BENEFITS Instantaneous water heater regulation with an accelerated thermostatic control Capacity: up to 65 kw on in sufficient quantity Operates independently of differential pressure and flow temperature Minimum space required for installation Pipes and plate heat exchanger made of stainless steel Minimized risk of lime scale and bacteria formation Low heat loss VL.IE.X1.02 Danfoss 01/2013

15 Termix One-B with complete insulation Circuit diagram - example Termix One-B with complete insulation B Plate heat exchanger 7 Thermostatic valve DH supply DH return DCW Technical parameters: Nominal pressure: PN 16 DH supply temperature: T max = 120 C DCW static pressure: p min = 0,5 bar Brazing material (HEX): Copper Weight: kg (incl. packing) Dimensions (mm): H 435 x W 355 x D 195 (type 1+2) Connections sizes: DH + DCW + : Connections: 1 Domestic cold water (DCW) 2 Domestic hot water () 3 District heating (DH) supply 4 District heating (DH) return G ¾ (ext. thread) Wall Options: Booster pump (increases DH flow) Safety valve and non-return valve (10 bar) Safety valve with thermostatic circulation set Thermostatic circulation set Non-return and pressure equalizer (GTU) Seen from above : Capacity examples, 10 C/50 C Substation type Type 1 w/avtb 15 1 household Capacity kw Supply flow C Return flow C Pressure loss kpa Flow rate Secondary l/h Substation type Capacity kw Supply flow C Return flow C Pressure loss kpa Flow rate Secondary l/h Type w/avtb up to 4 households Gemina Termix A/S Member of the Danfoss Group Navervej DK-7451 Sunds Denmark Tel.: Fax: mail@termix.dk VL.IE.X1.02 Danfoss 01/2013 DEN-SMT/PL

16 Data sheet ThermoDual Domestic hot water charging system Description / Application ThermoDual is the compact and effective domestic hot water () charging system. Due to the consistent use of carefully selected components and highest quality materials, the compact the ThermoDual system meet all of the requirements for the prevention of legionella growth. The highly efficient heat transfer of the heat exchangers enable The ThermoDual system to attain low heating water return temperatures across the entire cycle of a tank charge, thus reducing the required media flows. This translates into greater operational efficiency and predestines this system for utilization in district heating networks and in combination with condensing boilers. The optimum adaptation to the applicable specific needs in terms of storage capacity and output ensures a maximum of efficiency, comfort and hygiene. Main system data Secondary Type S GS - Max. operating temp. ( C) Max. operating pressure (bar) Working medium Circulation water / Approvals and Standards: - W 553 of the DVGW 2 working temperature / circulation, - W 551 of the DVGW 2 prevention of legionella growth, - DIN4753 storage tank. 2 German Technical and Scientific Association for Gas and Water ThermoDual - S Compact charging system with stainless steel domestic hot water storage tank and brazed plate heat exchanger as well as pre-installed piping assembly with allrequired fittings for installation. ThermoDual - GS Compact charging system with stainless steel domestic hot water storage tank and gasketed plate heat exchanger as well as pre-installed piping assembly with all required fittings for installation. DEN-SMT/PL VD.KR.C4.02 Danfoss 12/2013 1

17 Data sheet ThermoDual charging system Ordering Explanation, ThermoDual types ThermoDual - S Numbers for plates for heatexchanger Volume storage tank (liter) Type S with brazed plate heat exchanger GS with gasketed plate heat exchanger charging system with pre-installed pipes assembly with all required fittings for installation ThermoDual - S (brazed plate heat exchanger) Type Code No. S VA 004F7468 S VA 004F7469 S U1700 S U1701 S U1702 S U1703 S U1707 S U1708 S U1709 S U1710 S U1711 S U1712 S U1714 S U1715 S U1716 S U1717 S U1718 S U1719 S U1721 S U1722 S U1723 S U1724 S U1725 S U1726 S U1727 S U1729 S U1730 S U1731 S U1732 S U1733 S U1734 S U1737 S U1738 S U1739 S U1740 S U1741 ThermoDual - GS (gasketed plate heat exchanger) Type Code No. GS U1743 GS U1744 GS U1748 GS U1749 GS U1753 GS U1754 GS U1755 GS U1756 GS U1758 GS U1759 GS U1760 GS U1761 GS U1763 GS U1764 GS U1765 GS U VD.KR.C4.02 Danfoss 12/2013 DEN-SMT/PL

18 Data sheet ThermoDual charging system Main components Main components in standard system: - -approved charging pumps, 4 - Storage tank, - Heat exchanger, - Shut-off valve, 5 - Balancing valve, - Safety valve, - Thermometer l high efficiency pump (EEL <= 0,23) l - without 200 l - 2 thermometers, 2 valves Accessories The ThermoDual system can be combined with a second multiple storage tanks for optimum tailoring to on-site conditions: - Stainless steel domestic hot water storage tank, series SE, capacity liters (assembling / pipes by customer) To connect circulation, system can be combined with pre-mounted circulation groups: For controlling temperature self acting or electronical controllers can be used: - self acting controllers VG/AVT/(STM) - electronical controller ECL 110/210/310 (assembling by customer) - other accessories see local pricelist Type Code V pc min [l/min] d p [kpa] V pc max [l/min] d p [kpa] connection 3a 3b lenght L [mm] weight [kg] TD-Z I 004U R 1" R 1¼ 544 5,3 TD-Z II 004U R 1 R 1¼ 544 5,3 TD-Z I 004U R 1¼ R 1¼ 535 5,5 V pc - min minimal selectable flow for circulation V pc - max maximal selectable flow for circulation d p - rest pressure available by V pc DEN-SMT/PL VD.KR.C4.02 Danfoss 12/2013 3

19 Data sheet ThermoDual charging system Technical data -S -GS Type temperatures prim./sec. [ C] Performance index NL* Connected load [kw] top delivery performance 10 -> 45 C [l/10 min] [l/h] pemanent delivery performance 10 -> 45 C [l/h] 10 -> 60 C [l/h] Heating water flow [l/h] > 35 / 10 -> > 25 / 10 -> Pressure loss HEX [kpa] > 35 / 10 -> * Performance index l NL acc. to DIN 4708 in relation to a storage tank water temperature of 60 C ** Charging pump; A.C. 1 ~ 230 V / 50 Hz; thermal motor overload protection or motor protection by integrated thermo switch Input [W]** max VD.KR.C4.02 Danfoss 12/2013 DEN-SMT/PL

20 Data sheet ThermoDual charging system Design and function 4 5 CVS/CVE HEL TC SFV TC shut off device balancing valve sensor (direct, cable / universal, surface) thermometer LPU DTA 3 drain / air vent (on site / by customer) 1 Connections: 1 Domestic water cold 2 Domestic water hot 3 Circulation (options) 4 Heating supply 5 Heating return 37 Domestic water load The domestic hot water flow pumped through the heat exchanger (HEL) by the charging pump (LPU) remains constant at all times and is preset via the balancing valve. Components: DTA Domestic buffer tank HEL HEX charging / load LPU Charging pump / load SFV Safety valve CVE Control valve electrical (accessory) CVS Control valve self-acting (accessory) The domestic hot water temperature is maintained at a constant level through a balancing valve via the water temperature controller (CVS / CVE). As a result, the following operation modes can be defined for the ThermoDual charging system: Low Load Operation During low load operation, all of the cold water flows through the heat exchanger (HEL). If the tap output is smaller than the flow pre-set by the balancing valve, a portion of the hot water (tap flow) flows to the tap locations in the upper part of the tank (DTA) as a bypass. The residual water is removed from the bottom of the tank (DTA), causing the tank (DTA) to be continually charged. The total tap output is covered by the heat exchanger (HEL), while the storage tank (DTA) is not being discharged. Peak Load Operation During peak load operation (higher demand that can be supplied by the available heating power), the pre-set cold water flow flows through the heat exchanger (HEL) and the residual water streams from the bottom to the top of the storage tank (DTA). The tap output is covered by the heat exchanger (HEL) while the domestic water storage tank (DTA) is being simultaneously discharged. Once tap operation ceases, the storage tank (DTA) is charged as described below. DEN-SMT/PL VD.KR.C4.02 Danfoss 12/2013 5

21 Data sheet ThermoDual charging system Charging Operation (no consumption) If there is no consumption the storage tank (DTA) is being charged. The total charging flow is removed through the bottom of the tank (DTA) and returned through the top of the storage tank (DTA) via heat exchanger (HEL). If the storage tank (DTA) is completely charged and no output consumption occurs, the control valve (CVS / CVE) closes and interrupts the heating water flow. A virtual flash showing the operations is available, please contact your Danfoss local representative. 6 VD.KR.C4.02 Danfoss 12/2013 DEN-SMT/PL

22 Data sheet ThermoDual charging system Sizing Dimensioning and selection of the ThermoDual system should be carried out with the support of the Danfoss dimensioning program. Dimensioning Diagram for Dwelling Houses acc. to DIN 4708 Example: Performance index:... NL 60 Selected: Storage tank capacity: liters Evaluated: Power consumption: kw DEN-SMT/PL VD.KR.C4.02 Danfoss 12/2013 7

23 Data sheet ThermoDual charging system Mounting ThermoDual - S After the storage tank has been set up, the heat exchanger is attached. The pre-mounted fitting set, charging pump and stainless steel pipe can be easily installed due to mainly flat screw-top connections. The blow-off pipe of the safety valve is to be installed by the customer, based on local conditions and requirements. ThermoDual - GS Connect the storage tank and the heat exchanger with the pre-mounted piping set, fitting sets and charging pump. The blow-off pipe of the safety valve is to be installed by the customer, based on local conditions and requirements. Dimensions ThermoDual - S-100 ThermoDual - GS 05 B T T D D 02 H 03 H D ThermoDual - S B H T 8 VD.KR.C4.02 Danfoss 12/2013 DEN-SMT/PL

24 Data sheet ThermoDual charging system - S - GS Type H D B T [mm] [mm] approx. 9 [mm] approx. 9 [mm] 1,2 Rp connections 3 Rp 4,5 DN/G weight 6 [kg] ¾" ¾ ½ / " " ¾ ½ ¼ Tare weight without water 7 Welding tails 26,5 2,3 mm (up tp 130 kw) / 150 kw: - 33,7 2,6mm) 8 External thread acc. ISO 228/1 9 Tolerance: +/-10 mm DEN-SMT/PL VD.KR.C4.02 Danfoss 12/2013 9

25 Data sheet ThermoDual charging system 10 VD.KR.C4.02 Danfoss 12/2013 DEN-SMT/PL

26 Akva Therm II LV Domestic hot water charging system for hospitals, restaurants, sporting centres as well as commercial buildings and apartment blocks Domestic hot water charging system. Can be supplied directly from district heating supply networks, from low-temperature or condensing boilers, solar-, process- or waste heat systems. Application The Akva Therm II LV is a compact and effective domestic hot water () charging system. It optimally combines the two systems, storage water heating and instantaneous water heating and is applicable for hospitals restaurants, sport centres as well as commercial buildings and apartment blocks, where a constant temperature even during peak consumption periods is needed. The Akva Therm II LV can be supplied from district heating supply networks, from low-temperature or condensing boilers, solar-, process- and waste heat systems. Domestic hot water The Akva Therm II LV charging system is delivered as a set consisting of a stainless steel cylinder, a brazed, stainless steel plate heat exchanger, Danfoss XB37H-1, Danfoss ECL 310 for control of the charging temperature and temperature in the cylinder, Wilo low-energy circulation pump, shut-off valves, balancing valves / flow limiter, safety valves, thermometers as well as readyto-mount pipes and fittings. Domestic hot water circulation The Akva Therm II LV charging system is supplied with connection for circulation. The circulation pipe connection is placed directly on the cylinder. Design A total of 24 standard applications are available in the LV series, however, the possibilities are many, as the heat exchanger size and cylinder volume can be combined according to requirement. The capacities of the heat exchangers range from 25 and 110 kw and the tanks are available in sizes from 350 to 1000 liters. The standard executions supplies 12 to 69 apartments. For other sizes, please contact our sales department. Long life The use of acid-resistant, stainless steel for pipes, tank and heat exchanger, and dezincification-resistant brass for T- pieces, components and valves, as well as approved components secures the charging system a long life. Good operating economy, By using Danfoss automatics for the control of the Akva Therm II LV charging system the system is optimized in order to achieve higher efficiency and better cooling. The LV unit is characterized by a good stratification in the cylinder. Circulation is connected to the cylinder center and the return does not affect the stratification of the system. The electronic control and stratification ensures excellent operating economy. Serviceability and ease of assembly The charging unit can easily be mounted and serviced, as all parts are assembled with nuts and gaskets. FEATURES & BENEFITS Charging system for domestic hot water Can be supplied from district heating supply networks, from low-temperature or condensing boilers, solar, process and waste heat systems Available in standard executions for supply of apartments Electronic control - excellent operating economy Pipes, cylinder and heat exchanger made of stainless steel VL.GE.F2.02 Danfoss 11/2013

27 Akva Therm II LV Circuit diagram - example DH Supply DH Return Circ. 2. Brazed plate heat exchanger, stainless steel AISI Ball valve 9. Charging pump 12. Safety valve 10 bar 13. Thermometer 17. Air valve 20. Balancing valve 25. Domestic hot water control ECL 310, app Sensor 31. Actuator Valve Fully insulated storage tank, stainless steel Supply limit DCW 155 Technical parameters: Nominal pressure: PN 16 / PN 10 Max. temperature: 95 C (construction temp.) Min. ΔP: See capacity examples Weight incl. packing: LV kg LV kg LV kg LV kg Dimensions, tank: LV16-350: H 1750 x D 720 mm LV20-500: H 1890 x D 720 mm LV36-750: H 2130 x D 920 mm LV : H 2180 x D 1060 mm L: Dia L: Dia L: Dia L: L: L: L: 2180 Connections: 1. District heating (DH) supply 2. District heating (DH) return 3. Domestic cold water (DCW) 4. Domestic hot water () 5. Circulation (optional) 6. Circulation Connections (examples): LV16-350: DCW, 1 DH., Circ. ¾ LV20-500: DCW, 1½ DH ¾., Circ. 1 LV36-750: DCW, 2 DH., Circ. 1 LV : DCW, 2 DH., Circ. 1 : Capacity examples 60/15-10 C / 50 C Akva Therm II LV Type Tank volume No. of apartments. (guiding)* Heat exchanger (kw) Constant, (l/h) Capacity Max. capacity (l/h) Danfoss Redan A/S District Heating Omega 7 DK-8382 Hinnerup Tel.: Fax: redan@danfoss.com Max. capacity l/10 min.) Pressure loss bar LV LV LV LV LV LV LV LV LV Flow (l/h) VL.GE.F2.02 Danfoss 11/2013 DKDHR

28 MAKING MODERN LIVING POSSIBLE Termix One -B Instantaneous water heater for flats, single-family houses and small apartment buildings with up to 10 flats Instantaneous water heater with heat exchanger and thermostatic control. Designed for wallmounting. Application The Termix One is an instantaneous water heater featuring superb heat extraction and high performance. The Termix One is suitable for flats, single-family houses as well as for small apartment buildings with up to 10 apartments. The water heater is available in three sizes, either for 1 apartment, for 1 4 apartments or for 5 up to 10 apartments. The Termix One is applicable for decentralized heating systems as well as for district heating networks with summer operation at low temperatures or changes in differential pressure. The Termix One heat exchanger cools the district heating water very efficiently, thereby creating a very good operation economy. Domestic hot water () The domestic hot water is prepared in the heat exchanger and the temperature is regulated with a thermostatic control valve. The patented sensor accelerator accelerates the closing of the Danfoss AVTB valve and protects the heat exchanger against overheating and lime scale formation. The sensor accelerator and AVTB valve also works as a bypass keeping the house supply line warm. This shortens the waiting periods during summer when the heating system is in reduced operation. The sensor accelerator helps to ensure a stable hot water temperature by varying loads, flow temperatures and differential pressure without the need for readjusting the valve. There is no additional pressure loss on the secondary side of the heat exchanger with a thermostatic control. Therefore this type of regulation can be used by low pressure on the in the cold water mains. Options The water heater can be supplied with a (built-in) in non-return valve and safety valve mounted in the cold water supply. The water hater can also be supplied with a thermostatic circulation valve and a non-return and pressure equalizer (GTU). Construction All pipes are made of stainless steel. The connections are made by nuts and gaskets. The Termix One is delivered with an attractive steel grey cover in modern design, emphasising the high level of quality and comfort which characterises this product. FEATURES AND BENEFITS Instantaneous water heater regulation with an accelerated thermostatic control Capacity: up to 90 kw on Capacity: 15 kw HE, 55 kw TWW in sufficient quantity Operates independently of differential pressure and flow temperature Minimum space required for installation Pipes and plate heat exchanger made of stainless steel Minimized risk of lime scale and bacteria formation districtenergy.danfoss.com

29 Termix One -B Circuit diagram example DH Supply Termix One with GTU DH Return 7 B DCW B Plate heat exchanger 7 Thermostatic valve 21 To be ordered separately 62 GTU pressure equalizer DH Supply DH Return 7 B Circ. DCW Termix One with safety valve B Plate heat exchanger 2 Non-return valve 4 Safety valve 6 Thermostatic / non-return valve 7 Thermostatic valve 21 Thermostatic valve Technical parameters: Nominal pressure: PN 16 DH supply temperature: T max = 120 C DCW static pressure: P min = 0.5 bar Brazing material (HEX): Copper Weight incl. cover: Cover: kg (incl. packing) Grey-lacquered steel Dimensions (mm): Without cover: H 428 W 312 D 155 ( type 1+2 ) H 468 W 312 D 155 ( type 3) With cover: H 430 W 315 D 165 ( type 1+2 ) H 470 W 315 D 165 ( type 3) Connections: 1. Domestic cold water (DCW) 2. Domestic hot water () 3. District Heating (DH) supply 4. District heating (DH) return wall Connections sizes: DH + DCW + : G ¾ (ext. thread) Options: Booster pump (increases DH flow) Grey-lacquered steel cover Safety valve and non-return valvve (10 bar) Safety valve with thermostatic circulation set Pressure equalizer (GTU) : Capacity examples, 10 C / 50 C Substation type Type 1 w/avtb 15 1 household Type 3 w/avtb 20 5 to 10* households capacity [kw] Supply flow primary [ C] * Capacity for 10 households at 70 C DH flow temperature Return flow primary [ C] Pressure loss primary [kpa] Flow rate secondary [l/h] Substation type capacity [kw] Supply flow primary [ C] Return flow primary [ C] Pressure loss primary [kpa] Flow rate secondary [l/h] Type w/avtb up to 4 households Gemina Termix A/S Member of the Danfoss Group Navervej DK-7451 Sunds Denmark Tel.: Fax: mail@termix.dk VC.LA.Z3.02 Danfoss 01/2014 DEN SMT / PL

30 MAKING MODERN LIVING POSSIBLE Akva Lux II Fully insulated instantaneous water heater for low-temperature district heating Thermostatic and pressure controlled instantaneous water heater with heat exchanger. Unique temperature control with energy saving function and cold heat exchanger during standby. Application Akva Lux II is a fully insulated instantaneous water heater featuring high performance. It meets the future energy demands for low energy consumption and very low standby heat losses. It is especially suitable for large villas with for instance several bathrooms or jacuzzi and for the large family, for which an exceptionally large amount of water is required. The Akva Lux II is also very suiable for small apartment houses with 2-4 apartments. Construction The Akva Lux II water heater is prefabricated with a brazed, highly efficient Danfoss plate heat exchanger for domestic hot water production, a domestic hot water controller Danfoss PTC2+P, as well as a Danfoss FJVR thermostat for control of the bypass/circulation temperature. A circulation set and a safety set is available as optional equipment. Design The Akva Lux II is designed for wallmounting and much importance has been assigned to a user-friendly and easily accessible placement of all system components, including the controllers. The Akva Lux II is fully insulated in an EPP insulation box and can be supplied with a white-lacquered cover in modern design. Bypass (thermostatic circulation) The water heater is supplied with a thermostatically controlled bypass, which ensures that hot water is produced immediately, when tapping starts. The bypass temperature is set with due consideration of the best possible comfort and economy. Domestic hot water recirculation The water heater is prepared for domestic hot water circulation. If the household piping includes hot water recirculation the water heater must be connected to the hot water recirculation system and a circulation pump and a non-return valve must be mounted on the circulation pipe and a safety valve must be mounted in the DCW inlet. The pump must be installed so that it pumps towards the water heater. Domestic hot water recirculation ensures that hot water is available at the tapping point without waiting time and waste of water. The circulation temperature is set independently of the set temperature. This ensures the best possible comfort, very low standby losses and thus a very good district heating economy. Heat exchanger for heating The water heater is based on a brazed, highly efficient plate heat exchanger type XB 06H-1 26 or XB 06H-1 40, which is controlled by a thermostatic and pressure controlled controller, Danfoss PTC2+P with integrated differential pressure controller and energy saving function, which ensures that the heat exchanger is cold during standby. After completion of the tapping process, the controller immediately blocks the district heating flow, to avoid standby losses and to protect the heat exchanger from the formation of lime scale and FeATURES AND BENEFITS Prepared for low-temperature district heating Fully insulated and very low heat losses Cold heat exchanger during standby, - no standby losses controller PTC2+P with integrated differential pressure controller and energy saving function Pipes and heat exchanger made of stainless steel, connections with EPDM gaskets. Minimized risk of lime scale and bacteria formation Capacity: up to 53 kw growth of bacteria. The heat exchanger is cold during standby, so the heat loss is very low. The integrated differential pressure controller compensates for variations in supply temperature and varying differential pressure and thereby ensures a constant hot water temperature at all times. Service and maintenance The water heater is very service-friendly and easy to install. It is mounted on the wall and as all pipes are placed in pipe bracket distance, it is possible to establish a nice piping. districtenergy.danfoss.com

31 Akva Lux II Circuit diagram example 2 C B circ. A Danfoss, copper brazed plate heat exchanger in stainless steel AISI 316, type XB 06H-1 26 or XB 06H Domestic hot water controller Danfoss PTC2+P with energy saving function (= cold heat exchanger during standby). 40. By-pass/circulation thermostat Danfoss FJVR circulation: A. Connection of capillary tube from Danfoss FJVR acting as by-pass (standard function). B. Connection of capillary tube from Danfoss FJVR acting as circulation thermostat. C. Connection of circulation hose. Circulation set for control change from bypass to recirculation is not part of the delivery and must be ordered seperately. DCW DH supply DH return For systems with recirculation the water heater must be supplied with circulation pump, non-return valve and safety valve mounted in the cold water supply. Design specifications: Nominal pressure (prim/sec.): PN 16 / PN 16 Max. supply temperature: 120 C DCW static pressure: pmin = 2.0 bar Min. ΔP: See capacity examples Brazing material (HEX): Copper Weight excl. cover: XB06H-1 26 = 8 kg XB06H-1 40 = 9 kg Insulation: EPP λ Cover: White-lacquered steel Dimensions (mm): Insulated: H 463 W 306 D 190 Insulated with cover: H 463 W 310 D 210 Connections sizes: DH,, DCW: G ¾ ET (ext. thread) Circulation: R ½ ET (ext. thread) , (5) (w/o white cover) Connections: 1. Domestic cold water (DCW) 2. Domestic hot water () 3. District heating (DH) supply 4. District heating (DH) return 5. Circulation Code No s: Akva Lux II water heater with heat Insulated* Code no.: exchanger type: w/o cover 004U8243 XB 06H-1 26 w. cover 004U8245 w/o cover 004U8244 XB 06H-1 40 w. cover 004U8246 * Akva Lux II is fully insulated and available with out w/o white cover. Options: Cover H 410 x W 310 x D 210 mm Circulation set for mounting on site Safety valve set : Capacity examples, 10 C / 45 C capacity [kw] Plate heat exchanger Supply flow primary [ C] Return flow primary [ C] tap load [l/min] Pressure loss* primary [bar] Flow rate primary [l/h] 32.3 XB 06H XB 06H XB 06H XB 06H XB 06H XB 06H XB 06H XB 06H * Stated pressure loss values are complete, incl. pipes, heat exchanger and valves. Danfoss Redan A/S District Heating Omega 7, Søften DK-8382 Hinnerup Denmark Tel.: Fax: redan@danfoss.com VL.GP.G2.02 Danfoss 03/2014 DKDHR

32 MAKING MODERN LIVING POSSIBLE Termix One Solar Light Domestic hot water module for flats, single-family houses and apartment buildings with up to 10 apartments Domestic hot water module with heat exchanger and thermostatic control. Designed for wall-mounting. Application The Termix One Solar Light is an instantaneous water heater, featuring superb heat extraction and high performance. The Termix One Solar Light is applicable for heating systems with buffer accumulators, solar systems or for other heat sources, where a very low return temperature is preferred. The water heater is available in three sizes, either for 1 apartment, for 1-4 apartments or for 5 up to 10 apartments. The large heat exchanger cools out the water in the primary return line very efficiently, thereby creating a very good operation economy. A flow switch in cold water mains is controlling the primary heating pump. An optional circulation pump together with a thermostat can maintain the circulating temperature at a desired temperature. Domestic hot water () The domestic hot water is prepared in the heat exchanger and the temperature is regulated with a thermostatic control valve. The patented sensor accelerator accelerates the closing of the thermostatic control valve and protects the heat exchanger against overheating and lime scale formation. The sensor accelerator and the thermostatic control valve also works as a bypass keeping the heat exchanger and supply line warm. This shortens the waiting periods. The sensor accelerator helps to ensure a stable hot water temperature by varying loads, flow temperatures and differential pressure without the need for readjusting the valve. There is no additional pressure loss on the secondary side of the heat exchanger with a thermostatic control. Therefore this type of regulation can be used by low pressure in the cold water mains. Options The water heater can be supplied with the following: - Built in non-return valve and safety valve mounted in the cold water supply - Circulation set - Grey-lacquered steel cover - Two valve options (with or without DVGW approved valves for domestic water) Construction All pipes are made of stainless steel. The connections are made by nuts and gaskets. FEATURES AND BENEFITS Domestic hot water module regulation with an accelerated thermostatic control Capacity: Up to 90 kw on in sufficient quantity Operates independent of differential pressure and flow temperature Minimum space required for installation Pipes and plate heat exchanger made of stainless steel Minimized risk of lime scale and bacteria formation districtenergy.danfoss.com

33 Termix One Solar Light Circuit diagram example 230V M 230V O A B Termix One Solar Light O Termix Sensor Accelerator B Heat exchanger M Electrical wiring box 1 Ball valve 2 Single check valve 4 Safety valve 7 Thermostatic valve 11A Domestic hot water pump, w/built in check valve 13 Charging pump 21 To be ordered separately 35 Ball valve / non-return valve 39 Connection closed 45 Flow switch 48 Air vent, manual 63 Sieve Technical parameters: Nominal pressure: PN 16 DH supply temperature: T max = 120 C DCW static pressure: P min = 0,5 bar Brazing material (HEX): Copper Weight incl. cover: Cover: 20 kg (incl. packing) Grey-lacquered steel sheet Dimensions (mm): Without cover: H 714 W 300 D 160 With cover: H 714 W 315 D 165 With circulation With cover: H 960 W 400 D 190 seen from above wall Connections: 1. Domestic cold water (DCW) 2. Domestic hot water () 3. Buffer tank (BT) supply 4. Buffer tank (BT) return 5. Circulation Connections sizes: All connections: G ¾ (int. thread) Options: Safety valve and non-return valve (10 bar) Circulation Cover 4 ball valves 4 ball valves; hereof 2 with DVGW approval (ball valve length, incl. 1 gasket: 60 mm) (DVGW ball valve length, incl. 1 gasket: 79 mm) : Capacity examples 10 C / 50 C Substation type Type 1 w/avtb 15 1 household Type 3 w/avtb 20 5 to 10* huoseholds capacity [kw] Supply flow primary [ C] Return flow primary [ C] Pressure loss primary [kpa] Flow rate secondary [l/h] Substation type capacity [kw] Supply flow primary [ C] Gemina Termix A/S Member of the Danfoss Group Navervej DK-7451 Sunds Denmark Tel.: Fax: mail@termix.dk Return flow primary [ C] Pressure loss primary [kpa] Flow rate secondary [l/h] 29, , Type 2 34, , , , w/avtb 20 47, , , , up to 4 45, , , , households 65, , , , , , , , , , * Capacity for 10 households at 70 C DH flow temperature VL.JV.A1.02 Danfoss 10/2014 DEN SMT / PL

34 Data sheet ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection Description/Application The ThermoClean system is compact and effective solution for legionella-free domestic water heating. The system uses the thermal disinfection methods, whereby the reaction temperature inside the installation is kept at a constant temperature of 70 C. The ThermoClean system is dimensioned in such a way that the water is warranted to remain in the reaction area of the device for at least 5 minutes. During tap operation, the reaction temperature of 70 C is cooled down to the required hot water temperature within the system. This is not achieved by the addition of cold water, but through an additional re-cooling heat exchanger which cools the disinfected water, while preheating cold water, that simultaneous preheat the cold water. The hot water temperature can be set at any temperature between 50 C and 60 C. 1 It means that the installation of a scaling protection device on the taps is redundant if the temperature is adjusted accordingly. Due to the connection of the circulation into the system a continual thermal disinfection of the hot water is ensured. The high quality stainless steel design of reaction and buffer storage tank, heat exchanger and piping is hygienically perfect, offers a maximum in operational safety and can be universally used in combination with the wide range of materials used in the connected domestic water supply network. Main system data: 1 The recommended temperature is 60 C. Secondary Type DL/Combi Max. operating temp. ( C) 100 (150) 2 90 Max. operating pressure (bar) 16 (25) 2 10 Working medium Circulation water 2 On request Approvals and Standards: - DVGW 3 Working paper W 553 Calculation for circulation systems in installations, - DVGW 3 Working paper W 551 Technical method for prevention of legionella growth, - DIN Code of practice for drinking water installations (TRWI) (when related), - DIN EN Specifications for installations inside buildings conveying water for human consumstions, - DIN EN Protection against pollution of potable water installations and general requirements of devices to prevent pollution by backflow. 3 German Technical and Scientific Association for Gas and Water DEN-SMT/PL VD.KR.D5.02 Danfoss 09/2014 1

35 Data sheet ThermoClean Domestic water heating system ThermoClean -DL Domestic water heating system with electronic controls, a stainless steel reaction storage tank, charging and re-cooling brazed plate heat exchangers as well as charging pump, shut-off valves and complete stainless steel piping. ThermoClean -Combi Domestic water heating system with electronic controls, a combined stainless steel reaction and domestic hot water storage tank, charging and re-cooling brazed plate heat exchangers as well as charging pump, shut-off valves and complete stainless steel piping. The ThermoClean -Combi requires less installation space provided adequate height in the installation place is available. Ordering Explanation, ThermoClean types ThermoClean -DL 0200 TCTRL Electronic controller type Reaction tank volume (liter) Type DL with reaction storage tank and brazed plate heat exchangers Combi with combined reaction and storage tank and brazed plate heat exchangers Domestic water heating system with charging and re-cooling system unit ThermoClean Type Code No. -DL -Combi X X X X X X X X X X incl. electronic controller ThermoContol 2 VD.KR.D5.02 Danfoss 09/2014 DEN-SMT/PL

36 Data sheet ThermoClean Domestic water heating system Accessories 4 ThermoClean -DL 1. Domestic hot water storage tank The ThermoClean system must be combined with additional domestic hot water storage tanks to provide the required capacity for peak consumption. The required storage tank capacity is based on the calculated peak flow and the length of the consumption period. The recommendations provided overleaf for the total storage tank capacity are based on peak consumptions lasting 1 hour or according to customer demands. If the consumption periods are shorter, the storage tank capacity can be reduced accordingly. We recommend the utilization of the following storage tanks: - Stainless steel domestic hot water storage tank series SE, - Tank sizes: liters, - Optimum adaptation to requirements due to optional combination of multiple storage tanks. 2. Over-tapping protection Several unexpected factors can result in the complete consumption of the available storage tank capacity, which again can lead to the addition of domestic cold water to the hot water network that has not run through a proper thermal disinfection. The potential causes are for example: - Heating medium not available in sufficient quantity or at the adequate temperature, - Insufficient heat transfer in the heat exchanger due to fouling, - Technical defect of a system component (e.g., failure of the charging pump), - Peak consumption continues longer than the calculated consumption period. To address this issue, we offer products complementing our ThermoClean system that provide effective protection against system overtapping. If the storage tank capacity of thermally disinfected domestic water is beginning to run out, the protection interrupts the cold water supply to the system until the charging process has once again provided sufficient quantities of thermally disinfected domestic hot water via the reaction storage tank. Only after this process is complete, the cold water supply is established and the tapping of domestic hot water can be continued. The device is controlled via the ThermoClean system control with a manual switch (ON/OFF/AUTOMATIC). Over-tapping protection consisting of: - Motorized butterfly valve, nominal diameter corresponds to the selected ThermoClean system, actuator 1~230 V, three-point signal, - Control thermostat with stainless steel immersion pocket. ThermoClean -Combi 1. Over-tapping protection Please refer to above section ThermoClean -DL. 4 accessories for separately order Technical data Type Performance index Connected load Max. power for peak consumption Heating (Hot) water flow at ϑ VL = 75 C Domestic hot water capacities Permanent capacity Peak capacity Charge flow total Circ. flow (max.) Heating water Resistance NL 5 kw kw l/h l/h l/h l/s l/h l/h kpa kpa kpa , , DL , , , , , Combi , , , Performance index NL acc. to DIN Dependent on the additional storage tank(s) (max.) Circ. (max.) DEN-SMT/PL VD.KR.D5.02 Danfoss 09/2014 3

37 Data sheet ThermoClean Domestic water heating system Design and function ECD CPU DTA 45 RTA SFV HEL CVE 4 5 HEC CVD LPU 46 RTA reaction tank/vessel HEL HEX charging/load HEC HEX cooling LPU charging pump/load CPU circulation pump (on site/by customer) SFV safety valve CVE control valve electrical ECD electronic controller CVD control valve electrical domestic DTA domestic buffer tank (accessory) shut off device balancing valve sensor (direct, cable/universal, surface) 1) domestic water cold 2) domestic water hot 3) circulation 4) heating supply 5) heating return 45) to domestic buffer tank (stainless steel) top 46) from domestic buffer tank (stainless steel) below 47) from domestic buffer tank thermometer drain / air vent (on site / by customer) check valve sampling valve The heat exchanger brings the system volume to the disinfection temperature of 70 C. A temperature sensor at the exit of the heat exchanger monitors this temperature and regulates the application of heat energy accordingly. The system is dimensioned to ensure that the domestic hot water remains in the reaction area for at least 4 minutes to warrant the extermination of the legionella bacteria. The entire system volume is maintained at the defined disinfection temperature. Only when the water is tapped, the required quantity of water is cooled down to the demanded network temperature ( C) while the new cold water that is being added is preheated. Temperature fluctuations are balanced out by the mixing valve, so that the precise degree of water temperature indicated is definitely being maintained. Proven control technology ensures that the domestic hot water network is not heated up during breaks in tapping. If the consumption volume during peak times exceeds the charge flow of the system, the available storage tank volume is tapped. The optionally available over-tapping protection ensures that during unexpected functions (e.g. peak tapping continues for a period exceeding the determined consumption period) the cold water supply is suspended until sufficient thermally disinfected domestic water is once again available through the charging process via the reaction tank. The circulation water from the network enters the system, is once again heated up to 70 C by the charge heat exchanger and consequently incorporated into the thermal disinfection process continually. 4 VD.KR.D5.02 Danfoss 09/2014 DEN-SMT/PL

38 Data sheet ThermoClean Domestic water heating system Sizing For dimensioning and selection of ThermoClean system please contact with Danfoss local sales representative. Mounting ThermoClean -DL After setting up, connect reaction and storage tank, charge/re-cooling system unit via the pre-installed connections. Next the heating and domestic water connections, mains connections. Commissioning as described in the installation and operating instructions. ThermoClean -Combi After setting up, connect combination and storage tank, charge/re-cooling system via the pre-installed connections. Next the heating and domestic hot water connections, mains connections. Commissioning as described in the installation and operating instructions. Dimensions ThermoClean -DL B1 B ThermoClean -Combi B H1 H2 H H2 B2 D d T2 T1 D d T2 1 T1 Type H1 d D H2 approx. B1 approx. B2 approx. T1 approx. Connections Weight T2 approx. 10 Storage Re-cooling 1, 2 3 4, tank 11 unit 7 mm mm mm mm mm mm mm mm G/Rp G/Rp DN G/Rp kg kg kg G 1½ G 1¼ 25/20 G 1½ G 1¾ G 1½ 40 G 1¾ G 1¾ DL G 2 3 /8 G 2 3 / G 2 3 /8 50/ Rp Rp 920 Rp 2½ ½ Rp 65/ /2 -Combi G 1½ G 1¼ / G 1¾ G 1½ 32/ For ThermoClean type -DL incl. charging unit 8 Mounted on the ThermoClean -Combi s tank 9 min. door width; when needed components has to demounted 10 max. width of frame 11 raw weight (without insulation/package) All connection axis measures are approximate and have a tolerance of +/- 15 mm. Charging unit 8 DEN-SMT/PL VD.KR.D5.02 Danfoss 09/2014 5

39 Data sheet ThermoClean Domestic water heating system 6 VD.KR.D5.02 Danfoss 09/2014 DEN-SMT/PL

40 Data sheet ThermoClean Domestic water heating system DEN-SMT/PL VD.KR.D5.02 Danfoss 09/2014 7

41 Data sheet ThermoClean Domestic water heating system 8 VD.KR.D5.02 Danfoss 09/2014 DEN-SMT/PL

42 Data sheet ThermoDual - CM (Charging module) General Description / Use Domestic hot water provision by storage charging principle is an efficient solution that fulfils all hygienic requirements. Hot water is stored at temperatures that kill or prevent the growth of pathogens. Favourable habitats for the proliferation of bacteria such as legionella do not exist, provided the system is operated in accordance with the instructions. Ideally this requires an integrated circulation management. When combined with optimally hygienic stainless steel water tanks from our SE/SES series, these systems are the ideal solution where security of supply is of the essence, particularly at peak load. The system s essential benefits are: hygienically safe efficient cooling of the primary medium optimum use of energy free choice from a wide range of energy sources at all times sufficient hot water temperature to meet hygienic requirements constant hot water temperature Maximum operating parameters Maximum permissible supply temperature, primary 90 C / 150 C (without/with safety function) Maximum permissible operating pressure, primary 10 / 20 bar(g) Pumps and 3-way valve variant / Rated pressure, primary PN10 / PN25 2-way valve variant Maximum permissible pressure differential, primary only 2-way valve variant: 25 bar (up to 210kW) /16 bar Secondary Maximum permissible temperature, secondary 90 C Maximum permissible operating pressure, secondary 10 bar(g) Minimum required pressure (static), water supply Rated pressure, secondary Mains power supply / maximum power consumption 1.0 bar(g) PN10 230V DC / 4.0 A Materials Pipes, fittings, flanges, valves (domestic side) ditto (heating side) Heat exchanger Insulation , bronze or brass as per DIN EN 1982, also considering DIN and UBA guidelines P235GH-TC1, CuSn5Pb5Zn5-C (RG-5), ST37.0, EN-JL 1040 (GG25) with Cu solder PU hard foam λ=0.029 W/mK (50%ENEV) Code numbers Capacity [ kw] Pump + 3-way mixing valve Pump control (PWM control signal) Code no. 2-way valve (without safety function) 2-way valve (with safety function) X X X X X X X X X X X X X X X X X X X X X X X X1423 DEN-SMT/PL VD.IQ.I2.02 Danfoss 09/2014 1

43 Data sheet ThermoDual CM (Load module) Circuit diagram 3-Ways (MIX) Pump 2-Ways Control options on heating side Shut-off valve Non-return valve Check valve Balancing valve Air vent Drain Dain sampling valve (optional) HEL Heat exchanger, charging LPU Charging pump HPU Heating pump CPU Circulation pump SFV Safety valve CVE Motorized control valve (2/3-way) ECD Electronic domestic hot water controller (ThermoControl-3 ) STW Safety thermostat (optional) DTA Domestic hot water storage tank (installed by customer) 1 Domestic water (cold/charging) 2 Domestic hot water (hot/charging network) 3 Circulation (inlet) 4 Heating supply 5 Heating return TC Sensors (general: direct, immersion, surface) FLA with designation as for controller Technical data Type ThermoDual Capacity [kw] FRp (70->25 C) [m 3 /h] Pump dpr [kpa] 2-way dp [kpa] 3-way dpr [kpa] FR TW (10->60 C) [m 3 /h] DW dpr [kpa] FR C * (55->60 C) [m 3 /h] C dpr** [kpa] CM / / 43 CM / / 43 CM / / 43 CM / / 30 CM / / 30 CM / / 31 FR: Flow rate p: primary dpr: Remaining pump head dp: Pressure loss DW: Domestic water C: Circulation * flow rate: standard setup / maximal possible ** remaining pump head for: standard setup / maximal possible 2 VD.IQ.I2.02 Danfoss 09/2014

44 Data sheet ThermoDual CM (Load module) Function DTA ECD TC HEL TC CVE TC CPU 4 Low load operation (with circulation) In low-load operation, all the cold water passes over the instantaneous water heater (HEL). If the tap load is less then the flow pre-set at the balancing valve, a portion of the water (tap volume) flows trough the top of the tank (DTA) as bypass to the taps. The remaining volume is drawn from the bottom of the tank so that the tank (DTA) continues to be charged. The total tap load is covered by the heat exchanger (HEL), while the storage tank (DTA) is not being discharged. 5 TC TC LPU DTA ECD TC HEL TC CVE TC CPU 4 Peak load operation In peak-load operation, the pre-set flow of cold water passes through the instantaneous water heater (HEL) and the remainder flows through the tank (DTA) from bottom to top. The tap load is covered from the instantaneous water heater (HEL) and the storage tank (DTA) is simultaneously discharged. Once tap operation ceases, the storage tank (DTA) is charged as described below. 5 TC TC LPU ECD Charging operation (no tap load / circulation) If there is no consumption the storage tank (DTA) is being charged. The total charging flow is drawn from the bottom of the tank (DTA) and passed via the instantaneous water heater (HEL) to the top of the tank (DTA). TC DTA HEL CPU TC TC CVE 4 5 TC TC LPU VD.IQ.I2.02 Danfoss 09/2014 3

45 Data sheet ThermoDual CM (Load module) Dimensions Type ThermoDual DW C/H Circ. 1/2 G ISO 3 G ISO Connections: HTG (DN) SL, RL 4/5 PN10 Rp HTG (DN) SL, RL Pump + 4/5 PN25 3-way v. WELD Weight [kg] Pump control (PWM) 2-way v. CM ¼"A 1 ¼"A 1 ¼" CM ¼"A 1 ¼"A 1 ¼" CM ½"A 1 ¼"A 1 ½ CM ½"A 1 ¼ A 1 ½" CM ¾"A 1 ¼"A CM ¾"A 1 ¼ A 2" Correlation of connections 1 Domestic cold water 2 Domestic hot water 3 Circulation (inlet) 4 Heating supply line 5 Heating return line 4 VD.IQ.I2.02 Danfoss 09/2014 Produced by Danfoss A/S 09/2014

46 Data Sheet ThermoDual - FLS (welded type) General Description / Use Domestic hot water provision by instantaneous heater is an efficient and hygienic optimal solution. Hot water is not stored and will be produced only on request. Thus, low temperatures in drinking water can be reduced to a necessary minimum. Habitats for bacteria,such as legionella are virtually nonexistent. If the conditions for connection of these systems are given (sufficiently high capacity on heating side to cover peak load) or buffer tanks is present, these systems can be used unrestricted. Significant advantages of the system are: no storage of drinking water efficient cooling of the primary media optimum use of energy independent choice of different energy sources at any time sufficiently high domestic hot water temperature, that fulfils all hygienic requirements low space requirement lime scale is largely avoided Maximum operating parameters Maximum permissible supply temperature, primary 90 C / 150 C (without/with safety function) Maximum permissible operating pressure, primary 10 / 20 bar(g) Pumps and 3-way valve variant / Rated pressure, primary PN10 / PN25 2-way valve variant Maximum permissible pressure differential, primary only 2-way valve variant: 25 bar (up to 210kW) /16 bar Secondary Maximum permissible temperature, secondary 90 C Maximum permissible operating pressure, secondary 10 bar(g) Minimum required pressure (static), water supply Rated pressure, secondary Mains power supply / maximum power consumption 1.0 bar(g) PN10 230V DC / 4.0 A Materials Pipes, fittings, flanges, valves (domestic side) ditto (heating side) Heat exchanger Insulation , bronze or brass as per DIN EN 1982, also considering DIN and UBA guidelines P235GH-TC1, CuSn5Pb5Zn5-C (RG-5), ST37.0, EN-JL 1040 (GG25) with Cu solder PU hard foam λ=0.029 W/mK (50%ENEV) Code numbers Capacity [ kw] Pump + 3-way mixing valve Pump control (PWM control signal) Code no. 2-way valve (without safety function) 2-way valve (with safety function) X X X X X X X X X X X X X X X X X X X X X X X X1447 DEN-SMT/PL VD.HE.J3.02 Danfoss 09/2014 1

47 Data Sheet ThermoDual -FLS (welded type) Circuit diagram Shut-off valve Non-return valve Check valve Balancing valve HEL HPU CPU SFV CVE ECD STW BTA Heat exchanger Heating pump Circulation pump Safety valve Motorized control valve (2/3-way) Electronic domestic hot water controller (ThermoControl-3 ) Safety thermostat (optional) Hot water buffer tank (installed by customer) Air vent Drain Drain, sampling valve (optional) Flow sensor 1 Domestic water (cold) 2 Domestic hot water (hot network) 3 Circulation (inlet) 4 Heating supply 5 Heating return TC Sensors (general: direct, immersion, surface) FHZ : with designation as for controller Technical data Type ThermoDual Capacity [kw] FRp (70->25 C) [m 3 /h] Pump dpr [kpa] 2-way dp [kpa] 3-way dpr [kpa] FR DW (10->60 C) [m 3 /h] DW dp [kpa] FR C * (55->60 C) [m 3 /h] C dpr** [kpa] FLS , ,4 12 1,0 / 2,4 80 / 43 FLS , ,6 26 1,5 / 2,4 70 / 43 FLS , ,8 28 2,0 / 2,4 57 / 45 FLS , ,0 33 2,5 / 3,4 51 / 30 FLS , ,2 41 3,0 / 3,4 38 / 30 FLS , ,8 39 3,3 / 3,4 34 / 31 FR: Flow rate p: primary dpr: Remaining pump head dp: Pressure loss DW: Domestic water C: Circulation * flow rate: standard setup / maximal possible ** remaining pump head for: standard setup / maximal possible 2 VD.HE.J3.02 Danfoss 09/2014

48 Data Sheet ThermoDual -FLS (welded type) Function Flow systems provide heated domestic water when requested. By a heat exchanger (HEL), the cold water flowing into connection (1will be heated up to set point and provided to the consumer at the connection (2). The electronic controller (ECD) is measuring the relevant temperatures and controls the target values that are held constant in all operating conditions. This is i.e. achieved by influencing the speed of the heating pump (HPU), so that the outlet temperature always matches the specified value. In case of using a control valve, the flow is directly controlled by an electrical actuator. Short-term peaks in consumption are registered at the flow sensor to intervene quickly and avoid large temperature fluctuations. The cooled- circulation water from the network (connection 3) is constantly heated in heat exchanger (HEL), even in times of draw-off, reheated and the temperature control (sensor) in the amount of the controlled circulation pump ( CPU) influenced so that only the necessary amount flows to maintain constant power set point. The capacity for the peak load is to ensure either by buffering heating water in a tank (BTA) or there must be a sufficiently large connection value available. The Recharging of a buffer (e.g. from a boiler) can a requisition (sensor / switch contact) on controller (ECD) using an on-site charging pump (LPU). The operation of the system by a controlled heating pump (HPU) is only possible without differential pressure between the connections (4) and (5). Dimensions Type ThermoDual DW C/H Circ. 1/2 G ISO 3 G ISO Connections: HTG (DN) SL, RL 4/5 PN10 Rp HTG (DN) SL, RL Pump + 4/5 PN25 3-way v. WELD Weight [kg] Pump control (PWM) 2-way v. FLS ¼ A 1 ¼ A 1 ¼ 42, FLS ¼ A 1 ¼ A 1 ¼ 42, FLS ½ A 1 ¼ A 1 ½ 48, FLS ½ A 1 ¼ A 1 ½ 48, FLS ¾ A 1 ¼ A 2 60, FLS ¾ A 1 ¼ A 2 60, Correlation of connections Domestic cold water Domestic hot water 3 Circulation (inlet) 4 Heating supply line 5 Heating return line VD.HE.J3.02 Danfoss 09/2014 3

49 Data Sheet ThermoDual -FLS (welded type) Accessories Heating buffer storage tank, standing model, Type: PSS Charging-/Discharging Connections as threaded or flange connection Materials tank (shell) Insulation (from 750 Liter as bypack/not mounted) Steel EN S235JRG2 Raw inside, outside undercoat - black PU soft foam with PVC RAL 5015 up to PSS 300: 80 mm / from PSS 500: 100 mm Maximum operating parameters Maximum permissible operating temperature TZ 110 C Maximum permissible operating pressure PZ 6 bar Type I H mm H1 mm H2 mm H3 mm H4 mm H5 mm H6 mm H7 mm H Ma mm d mm D x mm D mm Tilted height mm 4/5 G 4/5 DN/PN /4" " " " / / Weight kg d D Dx 45 H 6 H max 45 H1 H2 22 H3 H4 H5 H6 H Charging-/Discharging conn. supply (hot) 5 Charging-/Discharging conn. return (cold) 6 Solar conn. / Reserve El. Heater Rp 2 22 Thermostat / Thermometer Rp 1/2 24 Air Vent Rp 3/4 25 Inspection, diameter opening 205 mm 26 Drain Rp 3/4 4 VD.HE.J3.02 Danfoss 09/2014 Produced by Danfoss A/S 04/2014

50 ThermoClean Domestic water heating system for hospitals, sports centers, hotels as well as dwelling-houses Domestic water heating system with legionella growth prevention through thermal disinfection Application ThermoClean is a compact and effective system solution for legionella-free domestic water heating. ThermoClean is suitable for hospitals, sports centers, hotels and dwelling houses, where effectively prevent the development and growth of legionella is needed. The system is available in two different types with separate reaction (-DL) or combination (-Combi) storage tank which contains the charging and recooling unit. These units are equipped with brazed (-DL/-Combi) plate heat exchangers. Domestic hot water () The ThermoClean system uses the thermal disinfection method, whereby the reaction temperature inside the installation is kept at a constant temperature of 70 C. It is dimensioned in such a way that the water is warranted to remain in the reaction area of the device for at least 5 minutes. The system is equipped with electronic controls for controlling of the charging temperature and the temperature in buffer storage tank. Domestic hot water circulation The ThermoClean system is supplied with connection for circulation including balancing valve and a nonreturn valve as a standard as well as circulation pump as an option. Options The ThermoClean -DL systems can be combined with additional buffer storage tanks to provide the required capacity for peak consumption. The system can be also equipped with the over-tapping protection to prevent system cool-down during over tapping. Construction The combination and reaction storage tank, plate heat exchangers and piping are made of stainless steel. All pipe connections are made by welding. The charging and re-cooling unit is mounted on a separated common frame construction. After setup the unit should be connected with reaction (combination) storage tank. FEATURES AND BENEFITS Domestic water heating system Electronic control of temperature Max. capacity: / kw 1 Reaction storage tank capacity: / l 1 Reliable prevention of legionella bacteria Continuous thermal disinfection of circulation Low operating cost Compact design and easy installation 1 ThermoClean DL/-Combi VL.KR.F3.02 Danfoss 12/2012

51 ThermoClean Circuit diagram - example DTA 45 RTA SFV LPU HEL CVE ECD 4 CPU HEC CVD RTA reaction tank/vessel HEL HEX charging/load HEC HEX cooling LPU charging pump/load CPU circulation pump (on site/by customer) SFV safety valve CVE control valve electrical ECD electronic controller CVD control valve electrical domestic DTA domestic buffer tank (accessory) 1) domestic water cold 2) domestic water hot 3) circulation 4) heating supply 5) heating return 45) to domestic buffer tank (stainless steel) top 46) from domestic buffer tank (stainless steel) below 47) from domestic buffer tank (stainless steel) top 46 thermometer shut off device drain / air vent (on site / by customer) balancing valve sensor (direct, cable/ universal, surface) check valve sampling valve Technical parameters: Type -DL/-Combi Nominal pressure: PN 16 (25) 2 DH supply temp.: T max = 100 (150) 2 C Options: Additional buffer storage tank Butterfly valve with electrical actuator Control thermostat with stainless steel immersion pocket 2 Available on request : Capacity examples Type Performance index NL 3 Connected load kw Max. power for peak consumption kw Circ. flow (max) l/h Heating water kpa Resistance (max) kpa Circ. (max) kpa H mm Dimensions W mm D mm Weight kg Connections 1, 2 3 4, /2 11/4 25/20 11/2 -DL /8 13/4 50/ / /2 2 50/40 21/ /2 11/ Combi /2 11/4 25/ /4 11/2 32/20-3 Performance index NL acc. to DIN Dependent on the additional storage tank(s) VL.KR.F3.02 Danfoss 12/2012 DEN-SMT/PL

52

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection Description/Application The ThermoClean system is compact and effective solution for legionella-free

More information

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line. MAKING MODERN LIVING POSSIBLE VX Solo II Substation for single-family, semi-detached and terraced houses as well as flats District heating substation for indirect heating. With connection pipes for W cylinder.

More information

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss. MAKING MODERN LIVING POSSIBLE Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept Safe and comfortable EvoFlat systems provide heating and domestic

More information

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems Akva Lux TDP-F Table of contents Akva Lux TDP-F... 1 Table of contents... 1 Safety notes... 2 Delivery...

More information

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2

More information

30% Take lead on your project with an efficient system concept. lower energy.

30% Take lead on your project with an efficient system concept. lower energy. Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept 30% lower energy consumption by individual metering in each apartment www.evoflat.danfoss.com

More information

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Akva Lux VX District heating substation for indirect heating and domestic hot water systems Akva Lux VX District heating substation for indirect heating and domestic hot water systems Akva Lux VX Table of Contents Akva Lux VX... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

WL Instantaneous water heater

WL Instantaneous water heater WL Instantaneous water heater WL Table of contents WL...1 Table of contents...1 Safety notes...2 Delivery...2 Transport and storage...2 Mounting...3 Pipes connections...3 Electrical connection...3 Filling,

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Akva Vita Instantaneous water heater

Akva Vita Instantaneous water heater Akva Vita Instantaneous water heater Akva Vita Table of Contents Akva Vita... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport and storage... 2 Mounting... 3 Pipes connections... 4 Electrical

More information

Instructions for installation and use Akva Lux II VX substations 1. Contents

Instructions for installation and use Akva Lux II VX substations 1. Contents Akva Lux II VX thermostatic control Akva Lux II VX thermostatic control, and optional junction box + zone valve Akva Lux II VX (ECL 110) Akva Lux II VX HWP (ECL210) Akva Lux II VX H2WP (ECL 210) 1. Contents

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

HW 22 District heating substation for indirect heating and domestic hot water systems

HW 22 District heating substation for indirect heating and domestic hot water systems HW 22 District heating substation for indirect heating and domestic hot water systems HW 22 Table of contents HW 22... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport and storage...

More information

MAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy

MAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy MAKING MODERN LIVING POSSIBLE Instructions for installation and use Danfoss District Energy substations Type 004U8264 Type 0048089 Cover for wall-mounting Type 0048044 Cover for recess mounting 1.0 Contents

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

a Danfoss Platform for Flensburg Secondary Network

a Danfoss Platform for Flensburg Secondary Network DSP MINI a Danfoss Platform for Flensburg Secondary Network General description and application The DSP MINI is designed for use in district heating networks, suitable for heating and for providing DHW

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

T. +44 (0) E.

T. +44 (0) E. Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

Reno Exchange of gas boilers.

Reno Exchange of gas boilers. District heating substation for exhange of Gas Boilers Akva Lux II TDP Reno District district heating substation for heating and domestic hot water. Reno Exchange of gas boilers. www.danfoss.com 1.0 Content

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy Contact person RISE Björn Folkeson 2017-08-15 7P03675B 1 (11) Energy and circular economy +46 10 516 54 46 bjorn.folkeson@ri.se Gemina Termix A/S Navervej 15-17 DK-7451 SUNDS Danmark Testing of a HIU according

More information

Increase the attractiveness of your multi-family building

Increase the attractiveness of your multi-family building Modern heating technology for housing associations Increase the attractiveness of your multi-family building Energy-efficient and reliable heating solutions. Up to 23% energy savings thanks to intelligent

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

Design & Product Guide. Danfoss FlatStations.

Design & Product Guide. Danfoss FlatStations. Design & Product Guide Danfoss FlatStations www.sav-systems.com Rev: 8.0 07/2016 About SAV Systems SAV has been operating in the UK since 1988. SAV Systems is a leading provider of innovative building

More information

MAKING MODERN LIVING POSSIBLE. Akva Vita II TD & S Akva Lux II / Akva Les II TD & S. Instructions for installation and use. Danfoss District Energy

MAKING MODERN LIVING POSSIBLE. Akva Vita II TD & S Akva Lux II / Akva Les II TD & S. Instructions for installation and use. Danfoss District Energy MAKING MODERN LIVING POSSIBLE Akva Vita II TD & S Akva Lux II / Akva Les II TD & S Instructions for installation and use Danfoss District Energy Akva Vita II TD Akva Lux II TD Akva Les II TD Akva Vita

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

Brazed heat exchanger XB

Brazed heat exchanger XB Description The XB is a range of copper brazed plate heat exchangers for use in District Heating (DH) and District Cooling (DC) applications, e.g. domestic hot water production, district heating substation

More information

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to.   Brazed Micro Plate heat exchangers Brazed Micro Plate heat exchangers Ultra-efficient brazed heat exchangers for your district energy applications Featuring the revolutionary Micro Plate technology innovation transferred Up to 35% lower

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

Technical paper Selection of district heating house stations

Technical paper Selection of district heating house stations MAKING MODERN LIVING POSSIBLE Technical paper Selection of district heating house s Herman Boysen, Product Application Manager, Danfoss A/S Published in EuroHeat & Power English Edition III 2004 districtenergy.danfoss.com

More information

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems. AB-PM Consistent hydronic control Continuous energy savings AB-PM automatic balancing valve for a reliable and energy-saving heating system. 1 valve needed instead of 3 for pressure, flow and zone control

More information

TERMO Combi Cylinder TECHNICAL INFORMATION

TERMO Combi Cylinder TECHNICAL INFORMATION TECHNICAL INFORMATION TERMO Combi Cylinder Tank-In-Tank System using solar energy for hot water and heating support. For integration into the heating circuit as return flow booster or hydraulic compensator.

More information

Danfoss Solar Solutions Application Handbook

Danfoss Solar Solutions Application Handbook MAKING MODERN LIVING POSSIBLE Danfoss Solar Solutions Application Handbook Danfoss district heating Meeting your requirements - for a truly efficient use of solar energy Increased requirements for energy

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

Domestic Hot Water Application manual

Domestic Hot Water Application manual Document Electrical Heating category Product name Domestic Hot Water Application manual 90% of the Legionella bacteria dies within the first 2 min at 60 C Let Danfoss do the work Index Danfoss Group is

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

IDEA CAMPUSENERGY2017 February Miami, FL

IDEA CAMPUSENERGY2017 February Miami, FL IDEA CAMPUSENERGY2017 February 20-24 Miami, FL Low Temperature Thermal Networks: Domestic Hot Water Production Jeff Flannery Table of contents 1. Objective for DHW devices 2. Building demands 3. Centralized

More information

Wall-mounted substation PKL-113

Wall-mounted substation PKL-113 Wall-mounted substation PKL-113 You have chosen a high-quality product to your home. We hope you will be as pleased with the substation as those customers we have served for over 30 years! Application

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

AVTI Multifunctional self - acting controller

AVTI Multifunctional self - acting controller AVTI Multifunctional self - acting controller Description / Application AVTI is a self - acting combined controller developed for controlling small heat units with a room heating system and a hot service

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List Technical Data Manual Model Nos. and pricing: see Price List VITOCELL 300-H EHA Series Indirect-fired domestic hot water storage tank 42 to 119 USG (160 to 450 L) Product may not be exactly as shown Vitocell

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

FASTflo. Working towards a cleaner future

FASTflo. Working towards a cleaner future NOW INCLUDES FASTflo PLUS Condensing Model FASTflo Continuous Flow Wall Hung range Balanced Flue Water Heaters Working towards a cleaner future FASTflo Continuous Flow Wall Hung Balanced Flue Water Heaters,

More information

Technical paper Hydraulic balance in a district cooling system

Technical paper Hydraulic balance in a district cooling system MAKING MODERN LIVING POSSIBLE Technical paper Herman Boysen, Product Application Manager, Danfoss A/S Published in DBDH 2003 (www.dbdh.dk) districtenergy.danfoss.com TECHNICAL PAPER Hydraulic balance in

More information

The solutions are here The choice is yours...

The solutions are here The choice is yours... Hydronic Balancing and Control The solutions are here The choice is yours... 1255 products to support your business The extended Hydronic Balancing and Control product range offers a solution for every

More information

MAXIMISER Semi-Storage Calorifiers

MAXIMISER Semi-Storage Calorifiers MAXIMISER Semi-Storage Calorifiers Introduction THE RYCROFT MAXIMISER HAS BEEN DEVELOPED TO MEET TODAY S NEED FOR A COMPACT CALORIFIER WHICH WILL RESPOND TO HIGH PEAK LOADS WITH MINIMAL DEMAND FOR BOILER

More information

KEMPER ThermoSystem. For further information on KTS use the QR code!

KEMPER ThermoSystem. For further information on KTS use the QR code! KEMPER ThermoSystem Heating water hygienically and energy-efficiently with patented cascade rotation for automated operating change among all heating modules For further information on KTS use the QR code!

More information

Herz York Direct Heat Interface Unit

Herz York Direct Heat Interface Unit www.herzvalves.com Herz York Direct Heat Interface Unit The Modern Solution for Apartment Heating and Domestic Hot Water Services General Description The Herz York Direct HIU is suitable for all community

More information

Hot water on demand with incorporated energy saving function

Hot water on demand with incorporated energy saving function Electric Instantaneous Water Heaters Hot water on demand with incorporated energy saving function Electric instantaneous water heaters The good feeling of doing the right thing. Electric warm water production

More information

Heat Interface Units for decentralised water heating in district heating systems

Heat Interface Units for decentralised water heating in district heating systems www.herz.eu Heat Interface Units for decentralised water heating in district heating systems HERZ Heat Interface Units High-quality decentralised water heaters with heating connection, for drinking water

More information

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit Multi-function compact unit for temperature control, thermal disinfection and distribution for hydraulic and domestic water system 6005 series ACEDITED ISO 9001 FM 21654 01160/17GB replaces dp 01160/08GB

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

DMS Best water heating technology

DMS Best water heating technology DMS Best water heating technology Established in 1974, DMS is now one of the industrie s leading companies. Complete hot water equipment for a variety of applications is produced in three modern plants

More information

Gasketed and brazed plate heat exchangers

Gasketed and brazed plate heat exchangers Gasketed and brazed plate heat exchangers Contents Gasketed plate heat exchangers Options Brazed plate heat exchangers Options 14 22 30 32 www.fiorinigroup.it 11 Gasketed and brazed plate heat exchangers

More information

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution

More information

Hydraulic balance in a district cooling system

Hydraulic balance in a district cooling system Article Hydraulic balance in a district cooling system Herman Boysen, Product Application Manager, Danfoss A/S, Published in DBDH 2003 (www.dbdh.dk) www.danfoss.com Herman Boysen Product Application Manager,

More information

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy Contact person RISE Björn Folkeson 2017-09-21 7P03972 1 (13) Energy and circular economy +46 10 516 54 46 bjorn.folkeson@ri.se Thermal Integration Ltd 8 Curzon Road Sudbury Suffolk CO10 2XW Great Britain

More information

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water AQUAMATIC HOT WATER IS YOUR NEW WELLNESS Instant producer of sanitary hot water Aquamatic All the water that you need at the temperature you desire the best AQUAMATIC is the new system for the production

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

Radiator Trap Radiator Valve

Radiator Trap Radiator Valve Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

product overview ProControl

product overview ProControl product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.

More information

Instructions. VX Solo II. 1.0 Table of contents

Instructions. VX Solo II. 1.0 Table of contents 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes...2 3.0 Storage and Handling...2 4.0 Disposal...2 5.0 Diagram - Examples...3 5.1 H (ECL 110) - With one heating circuit...3 5.2 H2 (ECL

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature

More information

Stored Water District Heating Interface Units. Heat Interface Units

Stored Water District Heating Interface Units. Heat Interface Units Stored Water District Heating Interface Units Heat Interface Units Why choose Elson Elson are a Heatrae Sadia company, the UK s leading manufacturer of hot water solutions utilising thermal store technology

More information

Distribution systems in apartment buildings

Distribution systems in apartment buildings Article Distribution systems in apartment buildings Halldor Kristjansson, Danfoss A/S www.danfoss.com Halldor Kristjansson, Danfoss A/S Published at the 11th International Symposium on District Heating

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

VORTEX. Pumps for domestic hot-water. Technical structure Pumps Motors Accessories Spare parts Replacement overview.

VORTEX. Pumps for domestic hot-water. Technical structure Pumps Motors Accessories Spare parts Replacement overview. VORTEX Pumps for domestic hot-water Technical structure Pumps Motors Accessories Spare parts Replacement overview www.deutsche-vortex.de VORTEX Pumps for domestic hot-water 3 BW-SL 154 with AUTOlearn technology

More information

10% better heat transfer using our patented Micro Plate TM technology.

10% better heat transfer using our patented Micro Plate TM technology. MAKING MODERN LIVING POSSIBLE Gasketed plate heat exchangers Next generation heat exchangers Next generation gasketed for your district energy applications heat exchangers for your district energy applications

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY WHAT DOES TACONOVA STAND FOR? Taconova Group AG is a well-established Swiss company with over years of experience in providing intelligent building

More information

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy Contact person RISE Daniel Månsson 2018-08-07 8P04823 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Flamco LTD Washway Lane, St. Helens Merseyside WA10 6PB Great Britain Testing

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION ECOplus Solar Cylinder Minimized Heat Loss due to convection brakes in the pipe connections, the new close-fitting, 00-mm thick PU soft foam jacket insulation, 0-mm thick and close

More information

WOLF GAS CONDENSING BOILERS COMFORTLINE

WOLF GAS CONDENSING BOILERS COMFORTLINE WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build

More information

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range Valves, controls + systems Innovation + Quality Stations for solar energy and solid fuel boilers Product range Stations for solar energy and solid fuel boilers Content Page Summary Stations for solar energy

More information

High-output calorifier Modul-plus

High-output calorifier Modul-plus High-output calorifier Modul-plus Favourite choice für refined domestic hot water convenience. 1 Modul-plus. Advantages at a glance It is the favourite choice for refined hot water convenience in renowned

More information

ACCUMULATION OF EUROPEAN CLASS

ACCUMULATION OF EUROPEAN CLASS ACCUMULATION OF EUROPEAN CLASS Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the

More information

Boiler Start-Up Cycle

Boiler Start-Up Cycle COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While Raypak boilers and water heaters can operate without

More information

COLD WATER START A P P L I C AT I O N S

COLD WATER START A P P L I C AT I O N S COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard efficiency boilers. While Raypak boilers can operate without harmful condensation

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

Valves, controls + systems Regudis W Dwelling stations

Valves, controls + systems Regudis W Dwelling stations Innovation + Quality Valves, controls + systems Regudis W Dwelling stations Product range Awards: Content 5 6 5 5 3 3 4 7 3 9 6 0 3 8 4 6 4 4 4 3 5 6 7 8 9 0 System illustration Page Content 3 Regudis

More information

VXi. Indirect, fully insulated district heating subtations Akva Lux II VXi, VXi Solo. Fully insulated for very low heat losses.

VXi. Indirect, fully insulated district heating subtations Akva Lux II VXi, VXi Solo. Fully insulated for very low heat losses. Indirect, fully insulated district heating subtations Akva Lux II VXi, VXi Solo Indirect district heating substation for heating and domestic hot water. VXi Fully insulated for very low heat losses. www.danfoss.com

More information

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

function Adjustable thee-way thermostatic mixing valve... connections 1/2, 3/4, 1 NPT male union and sweat union mixcal adjustable three-way thermostatic mixing valve series CCREITE ISO 9 FM ISO 9 No. CLEFFI / N Replaces / N LOW LE function The Caleffi MixCal three-way thermostatic mixing valve is used in systems

More information

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing

More information