1 MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands demanding commercial/industrial use Packaged System Factory selected and sized boiler water control valve simplifies installation and ensures reliable operation Versatile Full range of styles, sizes, and optional features to meet your exact heating needs Compact design requires minimal floor space Applications Schools Industrial Facilities Office Buildings Sports Venues Hotels Nursing Homes Hospitals A Heavy Duty Indirect Fired Water Heater The Model BWX is a fully packaged indirect fired water heater which utilizes boiler water or high temperature hot water (HTHW) as the energy source for heating potable water. The entire package is designed to be a reliable and long lasting source for hot water. Each component is carefully selected to ensure high performance in even the most demanding application. Model BWX Semi-Instantaneous Type The Model BW is equipped with all operating controls and ready for immediate installation ASME U Whether you are heating potable water in a commercial building or process water in an industrial application, you can select a Hubbell BWX model to do the job. When you specify and install a Hubbell water heater, you will be provided with a quality product that is a long lasting and trouble free source for hot water. A Packaged Water Heater Ready For Installation

2 Model BWX Semi Instantaneous Standard Equipment Vessel Construction 1. Designed and built in strict accordance with the ASME Code Section VIII and stamped, certified, and registered with the National Board of Boiler and Pressure Vessel Inspectors 2. Designed for 150 psi working pressure and hydrostatically tested Boiler Water Operating Controls 1. Operating controls are factory selected, sized, piped, and tested to ensure reliable operation 2. All components are factory piped and ready for boiler water in and out connections 3. Modulating control valve (2-way, 3-way) to regulate the flow of heating water through the coil. Modulating control valve to be (electric, pneumatic) powered 4. All bronze integral circulating pump 5. Direct mounted boiler water and domestic water temperature and pressure gauges 6. High limit Single solenoid safety system closes the boiler water supply to the heating coil should the water temperature in the tank reach the hi-limit set point. Requires 120 volt 5 amp electrical service Heating Coil 1. Factory sized and installed copper heating coil with a generously sized heating surface designed to ensure reliable operation 2. U-Tube heating coil constructed from single wall copper tubing designed for a maximum working pressure of 150 psi 3. Heavy duty fabricated steel head with threaded NPT inlet and outlet connections 4. All wetted parts are non-ferrous for maximum longevity 5. Non-Ferrous tube sheet General 1. Heavy duty fiberglass insulation for maximum operating efficiency and minimal stand-by heat loss 2. Heavy gauge painted galvanized steel protective outer jacket 3. Heavy duty integrally welded steel supports for floor mounting 4. Full five (5) year Non Pro-Rated tank warranty and a one (1) year component warranty 5. ASME rated combination T&P relief valve set at the tank working pressure and 210 o F Optional Equipment NOTE: Other optional features are available, please consult factory if required. Vessel 1. Alternate vessel construction: Stainless Steel Type 304 or 316L, galvanized steel or 90/10 Copper-Nickel 2. Alternate working pressure: Please specify 3. Horizontal Construction General 7. Type 304 stainless steel protective outer jacket, please specify if painted. Heating Coil 4. Double wall tubing with a leak detection port 5. Alternate tubing material please specify: (Stainless Steel, 90/10 Copper-Nickel, Admiralty) 6. Fabricated head constructed from: (Stainless Steel, Copper Alloy) Operating Controls 8. Boiler water control valve can be factory selected and sized, but shipped loose for in the field installation by others 9. A double solenoid safety system dumps over heated water in the pressure vessel to drain in addition to closing the boiler water supply to the heating coil. Requires 120 volt 5 amp electrical service. 2

3 Vertical Dimensions (inches) Model No. Based on 100 FΔT Recovery Rate ( F) Base Model Recovery Rating (GPH) F BTU/Hr BWX ,000 BWX ,000 BWX ,000,000 BWX ,250,000 BWX ,500,000 BWX ,000,000 BWX ,500,000 BWX ,000,000 BWX ,500,000 BWX ,000,000 BWX ,000,000 Boiler Water Entering & Exiting Temperatures ( F) Vertical Model BWX Overall Dimensions (inches) Weight (Lbs) Single Wall Double Wall A B C D E A B C D E F F F F F F F F F F F F F F F F F F F F F F Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. Please consult factory for recovery ratings for boiler water temperatures not shown. Metric Conversion Liters x = Gallons Gallons x 3.79 = Liters Gallons x = m 3 m 3 x = Gallons O 1 C T = 1.8 O F T O F = ( O C x 1.8) + 32 O C = ( O F - 32) x psi x = Bar Bar x 14.5 = psi psi x 6.86 = kpa kpa x = psi Lbs x = Kg Kg x 2.2 = Lbs ft 2 x = m 2 m 2 x = ft 2 3

4 Indirect-Fired Semi-Instantaneous Outline Dimensions - Model BWX (Vertical) T&P Relief Valve Thermometer Hi-Limit Thermostat Pump Switch Recirculation Pump Pressure Gauge Cold Water Inlet D Hot Water Outlet Protective Jacket Temperature Controller Hi-Limit Solenoid Valve Insulation Drain Control Valve A B C E Indirect-Fired Semi-Instantaneous Outline Dimensions - Model BWXH (Horizontal) Control Valve Temperature Controller Hi-Limit Thermostate T&P Relief Valve Hot Water Outlet Pump Switch Drain Withdrawal Space Pressure Gauge Hi-Limit Solenoid Valve Insulation 4 Thermometer Protective Jacket Cold Water Inlet Recirculation Pump TOP VIEW END VIEW

5 Piping Layouts SINGLE UNIT Boiler Water Supply Hot Water Out Recirculation Cold Water In Boiler Water Return Drain Bypass Line if 3-Way Valve Hot Water Out DUAL UNIT Boiler Water u Boiler Water Ret Recirculation Supply rn Drain Drain Cold Water In 5

6 Piping Layouts SINGLE UNIT WITH STORAGE TANK Boiler Water Supply Hot Water Supply Recirculation Cold Water In St T o a r n a k ge Hot Water Out Boiler Water Return Drain Hot Water Return LEGEND Strainer Stop Valve Check Valve Control Valve Relief Valve Thermal Element Pressure Gauge Temperature Gauge Circulator Expansion Tank 6

7 Formulas To Determine The Boiler Water Flow Rate Required Domestic Water GPH Heated Domestic Water o F T x x Boiler Water Drop o F T = GPM Boiler Water Required To Determine Maximum Domestic Water Recovery Rate Boiler Water GPM Boiler Water Drop o F T x 60 x Domestic Water Rise o F T = GPH Domestic Water Heated Note: A minimum 10 o F differential ( T) between the exiting boiler water temperature and the exiting domestic hot water temperature is required to maintain efficient heat transfer rates. For detailed information regarding the heating coil, please reference the Hubbell brochure titled Hubbell Heating Coils. Examples A. I want to heat 950 GPH from o F with 180 o F B. I have 30 GPM of 200 o F boiler water that I can take boiler water that I can take down to 160 o F. How down to 160 o F. How many GPH of domestic water much boiler water must I have available? can I heat from o F? 950 x x (140-40) = = 79 GPM of 30 x 60 x ( ) = = 720GPH Boiler Water Domestic Water Model Number Designation BWX Model Number Designation Step 1 Model: BWX = Vertical BWXH = Horizontal Step 2 Step 3 Vessel Type: CN = 90/10 Copper-Nickel SS = Stainless Steel (Specify Type) M = Galvanized Steel Recovery Rating: In GPH at 100 o F T Step 4 Coil Type: S = Single Wall D = Double Wall Example: BWXCN-3600S A vertically installed semi-instantaneous indirect fired water heater with a 90/10 Copper-Nickel pressure vessel and single wall heating coil rated to heat 3600 GPH at a 100 o F temperature rise. Option Note Any and all optional equipment for a water heater must be called out in the written specifications. A model number in and of itself does not reflect any optional equipment selected. 7

8 Master Specification: Model BWX JOB NAME ENGINEER REPRESENTATIVE CONTRACTOR GENERAL Provide a quantity of semi instantaneous indirect fired water heater(s), Model No. as manufactured by HUBBELL Electric Heater Co., Stratford, CT. The pressure vessel shall be mounted on structural supports and be suitably insulated, jacketed and painted. The entire unit is to be packaged ready for service connections. PRESSURE VESSEL The pressure vessel section shall be constructed from 304 Stainless Steel material. ( Optional Specification: 90/10 copper-nickel or 316L stainless steel, Hot dipped galvanized steel). Vessel will be stamped for 150 PSI under Section VIII of the ASME Code. Manufacturer s data report and U-1 forms shall be furnished to the owner. No overhead clearance shall be required for servicing or removing the heating coil. Each heater shall be designed to heat GPH( GPM) of domestic water from to o F when supplied with GPM of boiler water entering at o F and exiting at o F. HEATING SECTION The heating coil shall be fabricated with single wall Optional Specification: Double wall) Copper tubes, ( Optional Specification: Stainless steel, 90/10 copper-nickel, admiralty) non-ferrous baffles and a copper-lined tubesheet. The heater shall have its temperature control bulb located for direct sensing of water. CONTROLS The water heater controls shall be factory assembled and piped. A modulating control valve shall be a ( Specify: 2-way or 3 way) type, ( Specify: Pneumatic or Electric) power valve. Solenoid control valves will not be accepted. Each heater shall be factory packaged with the following components: All bronze integral circulating pump with copper piping and isolation valves Direct mounted boiler water and thermometer gauges High limit safety system ASME rated temperature and pressure relief valve Fiberglass insulation with painted metal jacket OPTIONS In addition, the water heater shall be supplied with the following optional features: Option Option Option WARRANTY The water heater manufacturer shall warranty all components against defects in Workmanship and material for a period of one (1) year from date of start-up and the pressure vessel for a full five (5) years Non Pro-Rated ( Optional Specification: full ten (10) years Non Pro-Rated) from date of start-up, provided that the unit is started within three (3) months of date of shipment and installed and operated within the scope of the heater s design and operating capability. Each water heater shall be shipped with a complete set of installation and operating instructions including a spare parts list and approved drawing. Committed to continuous improvement... Continuing research results in product improvement; therefore specifications are subject to change without notice. For the most updated information, consult the factory directly. The Electric Heater Company P.O. Box 288 Stratford, CT Phone: Fax: info@hubbellheaters.com

Packaged Semi-Instantaneous Steam Fired Water Heater

Packaged Semi-Instantaneous Steam Fired Water Heater MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane

More information

Indirect Fired Water Heater

Indirect Fired Water Heater Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite

More information

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater MODEL E Light Duty Commercial Electric Water Heater 6-120 Gallon Capacity, up to 6 KW, Single Phase and Three Phase Open Delta Features Heavy Duty Construction High Efficiency Hydrastone cement lining

More information

Tepid Water Delivery System

Tepid Water Delivery System Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model ME Shipboard Electric Water Heater 6-119 Gallon Capacity, Up To 12 KW, Single Phase Marine Approvals United States Coast Guard (USCG) conformance and American Bureau of Shipping

More information

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

PROVIDES TEPID WATER FOR EMERGENCY SHOWER PROVIDES TEPID WATER FOR EMERGENCY SHOWER Model EMV FEATURES Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model MSE Shipboard Electric Water Heater 6-119 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model MSE Shipboard Electric Water Heater 6-120 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining

More information

ASME and Non-ASME Storage Vessels

ASME and Non-ASME Storage Vessels 6-5000 Gallon Capacity Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Non-ferrous tappings cannot rust or corrode High impact composite jacket eliminates damage during

More information

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY PRIME COMMERCIAL CONDENSING GAS WATER HEATER 40-119 GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY WATER HEATERS TM (Optional) TM THE ULTIMATE IN CONDENSING GAS WATER HEATING THE PRIME ADVANTAGE Industry's

More information

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY PRIME COMMERCIAL CONDENSING GAS WATER HEATER 40-119 GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY WATER HEATERS TM (Optional) TM THE ULTIMATE IN CONDENSING GAS WATER HEATING THE PRIME ADVANTAGE Industry's

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating

More information

Heat Pump Water Heater

Heat Pump Water Heater MODEL PBX Heat Pump Water Heater Fully Integrated Heat Pump Water Heater (HPWH) 40-119 Gallon Capacity Features Highest Efficiency Heat Pump transfers heat from surrounding air into the hot water tank

More information

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL BW and BWH HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD,

More information

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency NX COMMERCIAL INDUSTRIAL HEATER Condensing Gas Water Heating System 96% Thermal Efficiency Hubbell NX Input 200 to 800,000 BTU/H Easy use touch screen display Stainless steel heat exchanger Floor or wall

More information

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal SWH Series STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal NOW AVAILABLE Automated On-line Sizing Program STONESTEEL is a Registered Trademark

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

DI/RO GAS TANKLESS WATER HEATER

DI/RO GAS TANKLESS WATER HEATER WATER HEATERS Model DGX DI/RO TANKLESS WATER HEATER ANSI/NSF 5 Optional DI/RO GAS TANKLESS WATER HEATER For Heating Ultrapure / Reverse Osmosis / Deionized Water Available in 199,950 and 250,000 BTU/Hr

More information

Water Heaters. Solar Applications

Water Heaters. Solar Applications Water Heaters Applications (Optional) 3-way diverting valve Pump Bypass for Cooling Water Bypass Return STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK,

More information

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers

More information

COMMERCIAL SPACES WATER HEATING SOLUTIONS WATER HEATERS

COMMERCIAL SPACES WATER HEATING SOLUTIONS WATER HEATERS WATER HEATERS TM COMMERCIAL SPACES WATER HEATING SOLUTIONS PRECISELY ENGINEERED OFFICE BUILDINGS APARTMENTS & CONDOMINIUMS RETAIL SPACES MIXED-USE FACILITIES COMMERCIAL KITCHENS MECHANICAL ROOMS SPECIALITY

More information

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water Packaged Instantaneous Domestic Hot Water Generator Energy Source: Shown with optional boiler water valve and electronic feed-forward control. Operates with low boiler water supply and return temperatures

More information

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION SPH Series Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA

More information

OPERATING AND MAINTENANCE MANUAL FOR STEAM FIRED WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL ST and STH

OPERATING AND MAINTENANCE MANUAL FOR STEAM FIRED WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL ST and STH OPERATING AND MAINTENANCE MANUAL FOR STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL ST and STH HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203)

More information

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI. COBREX Semi-Instantaneous Steam-Fired Domestic Hot Water Generator ENGINEERED DUPLEX ALLOY Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty PVI.com Steam-Fired Domestic Hot Water Generator COBREX

More information

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F Count on Graham for proven reliability. Graham is one of the world s foremost designers and manufacturers of vacuum and heat transfer equipment with over a half-century of proven experience. Our in-house

More information

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers

More information

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters SEH Series Stainless Steel Instantaneous Packaged Steam Fired Water Heaters utomated On-line Sizing Program CEMLINE CORPORTION P.O. BOX 55 CHESWICK, PENNSYLVNI 15024 Phone: (724) 274-5430 FX: (724) 274-5448

More information

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION EHB Series STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55

More information

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Form No. 2300-7 (Rev. 2/99) Gas, il or Dual Fuel Fired Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Originators of the Flexible Water Tube

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

Heat Transfer Packages

Heat Transfer Packages Heat Transfer Packages Heat Transfer Package (HTP Series) Building Heat, Process Heat, Swimming Pool Heater, Cooling Applications and Snow Melt Package (SMP Series) Steam,, High Temperature Hot Water,

More information

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters FFH Series Steam Fired Instantaneous Feed Forward Water Heaters CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448 www.cemline.com Operation of Cemline

More information

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SH and H HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS Edition 2011 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615

More information

SECTION ELECTRIC WATER HEATERS

SECTION ELECTRIC WATER HEATERS SECTION 22 36 01 ELECTRIC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS Harsco Industrial Patterson-Kelley delivers the industry s most reliable, water heaters in the business. The Harsco Industrial Patterson-Kelley difference.

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL T Edition 0 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 88 STRATFORD, CT 0665

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 3300 - ELECTRIC, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

EZ Plate Instantaneous

EZ Plate Instantaneous EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted

More information

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

SECTION FUEL-FIRED DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not

More information

SECTION WATER HEATERS

SECTION WATER HEATERS SECTION 15457 WATER HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete hot water generating system with necessary accessories as indicated on Construction Documents, as specified, and

More information

Boiler & Water Heater

Boiler & Water Heater MIGHTY THERM2 Date: Project #: Pump-Mounted Boiler & Water Heater MT2H Hydronic Heater MT2V Volume Water Heater Indoor/Outdoor Sizes 500-2000 Submittal Engineer: Project Name: Prepared By: Location: Bid

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL SECTION 22 14 00 DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 00 10,

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List Technical Data Manual Model Nos. and pricing: see Price List VITOCELL 300-H EHA Series Indirect-fired domestic hot water storage tank 42 to 119 USG (160 to 450 L) Product may not be exactly as shown Vitocell

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters Low NOx, Quiet, Efficient, Space-Saving Mighty Therm Lo-NOx Greater energy efficiencies as high as 84% are achieved through

More information

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance Unfired Steam Generators (Series RB) Installation, Operation and Maintenance Horizontal USG Vertical USG 534-EN Please read and save these instructions Disclaimers This Installation, Operation, and Maintenance

More information

Raypak Residential Products

Raypak Residential Products Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper

More information

Precision Storage Vessels ELECTRIC WATER HEATERS

Precision Storage Vessels ELECTRIC WATER HEATERS Precision Storage Vessels ELECTRIC WATER HEATERS High Capacity Electric Water Heaters Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial application.

More information

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS...world leaders in heat transfer technology BW-533.indd 1 6/7/07 5:33:16 PM Standard Heat Exchanger Designs Deliver Cost Effective Performance To address the

More information

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS s superior ability to absorb and transfer heat makes it the ideal choice for comfortable and efficient heating systems. Since 11 Bradford White Corporation has been dedicated to building the highest quality,

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source USG Series Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430

More information

Installation, Operation and Maintenance

Installation, Operation and Maintenance Bulletin No. 534 Installation, Operation and Maintenance Unfired Steam Generators (Series RB) Horizontal USG Vertical USG Disclaimers This Installation, Operation, and Maintenance Manual is intended to

More information

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com Conquest Condensing Gas Water Heater E N GI N E E R E D D U P L E X A L L OY 199 to 300 MBH 100 Gallon Tank 15-year Warranty PVI.com Advanced Design with Longer Service Life Conquest is a compact, condensing,

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element Indirect Tanks for Domestic Hot Water New! Single coil tanks with electric element DHW Tanks FOR ALL SOLAR, GEOTHERMAL OR HYDRONIC APPLICATIONS LIMITED LIFETIME W A R R A N T Y Heavy Gauge Steel With Porcelain

More information

Indirect-Fired Water Heaters

Indirect-Fired Water Heaters Indirect-Fired Water Heaters Premier Series Dual Coil Commercial The growing importance of energy efficiency and today s high fuel prices means there s never been a better time to install an AMTROL Mate

More information

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section SPECIFICATION SHEETS Steam Sample Specification Water Sample Specification MOHICAN SPECIFICATION SHEET The following sample specifications are provided by Superior Boiler Works to assist you in providing

More information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:

More information

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk. Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single Indirect Water Heaters - Stainless Steel Storage Tanks - Stainless Steel Hydronic Buffer Tanks - Stainless Steel Single

More information

SECTION AIR COOLED WATER CHILLERS

SECTION AIR COOLED WATER CHILLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2

More information

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION $7.50 Installation, Operation, and Maintenance Manual CEMLINE CORPORATION Unfired Steam Generators (USG Series) Horizontal USG Vertical USG CEMLINE CORPORATION P. O. Box 55, Cheswick, PA, 15024 Phone:

More information

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR TURBOMAX Instantaneous Indirect Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Your TURBOMAX Instantaneous Indirect Water Heater has been carefully assembled and factory

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List VITOCELL 300-H Indirect-fired domestic hot water storage tank 42 to / 160 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell 300-H EHA Series Horizontal indirect-fired domestic hot

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL Manufacturer's Warning To reduce the possibility of injury due to scalding,

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

FUEL-FIRED VERTICAL TUBELESS BOILERS

FUEL-FIRED VERTICAL TUBELESS BOILERS FUEL-FIRED VERTICAL TUBELESS BOILERS 4 60 P orizontal and Vertical Feedwater / Condensate Return Systems and Blow-down Tanks FULTON FUEL-FIRED VERTICAL TUBELESS BOILERS FULTON: AN INDUSTRY LEADER SINCE

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)

More information

Domestic Pump Condensate Transfer Equipment

Domestic Pump Condensate Transfer Equipment Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com Condensate Return

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

High Efficiency Commercial Gas Water Heaters

High Efficiency Commercial Gas Water Heaters High Efficiency Commercial Gas Water Heaters 500,000 to 1, 300,000 Btu/hr Less Than 30 ppm NOx Up to 87% Thermal Efficiency The High-Efficiency, High-Output Compact Water Heater First Power-Fin production

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

Stainless Steel Indirect Water Heaters

Stainless Steel Indirect Water Heaters Stainless Steel Indirect Water Heaters 12 Squire Models to Choose From - 6 Standard Models from 30 to 119 Gallons - 6 Solar Models from 65 to 119 Gallons 316L Passivated Stainless Steel Tank 316L High

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information