General Outline: Altherma

Size: px
Start display at page:

Download "General Outline: Altherma"

Transcription

1 ESIE08-0 General Outline: Altherma Stacked The illustration below shows the required installation and service space (mm). Do not stack more than one unit. +/- 00 mm is required as the dimension for laying the upper outdoor unit s drain pipe. Get the portion A sealed so that air from the outlet does not bypass. Obstacles exist in front of the outlet side. 2 Obstacles exist in front of the air inlet. A A Multiple row The illustration below shows the required installation and service space (mm). Installing one unit per row. 2 Installing multiple units (2 units or more) in lateral connection per row L A H Relation of dimensions of H, A and L are shown in the table below. L A L H 0 < L /2H 20 /2H < L 00 H < L Installation impossible Part System Outline 2

2 General Outline: Altherma ESIE08-0. EKHBH(X)006AA***: Installation and Service Space EKHBH(X) The illustration below shows the minimum service space for service and ventilation. MINIMUM SPACE FOR SERVICE & VENTILATION Center of gravity 2 Part System Outline

3 ESIE08-0 General Outline: Altherma.2 Physical Limitations and Limits of Operation Distance between components The illustrations and table below show the limitations. OUTDOOR Domestic hot tank C G & G' F & F' way valve H B A INDOOR E I J Thermostat 2 way valve D Heat emitters Allowable heigth: Indoor Total system : 0 m (outdoor unit can be above or below the hydro-box) outdoor Piping R0A Piping water Power supply Communication A B C D E F & F G G H I J ERHQ0AA V ERHQ0AA V ERHQ06AA V * < A 7 m m 0 m depend on installation depend on installation depend on installation 2 m depend on installation > 0.0 m depend on installation depend on installation Remark A: Minimum allowed length is m. When < m, recharging of the outdoor unit is required. Refer to the installation manual of the outdoor unit. E: 2-wiring in/outdoor F: Power supply booster + Q2L safety F': Power supply solenoid valve (UK only) G: Thermistor cable supplied with the sanitary tank is 2 m in lenght. May not be changed. G': Feedback signal Q2L & QL safety (UK only) Part System Outline 2

4 General Outline: Altherma ESIE Part System Outline

5 ESIE08-0 General Outline: Altherma. EKHBDP - Drainpan Kit Necessity Decision graph for EKHBDP necessity Leaving water temperature limit to prevent condensation.0 Relative humidity 0% Relative humidity 0% Relative humidity 0% Maximum leaving water temperature cooling mode = 22 C. 2 Leaving water temperature ( C) Leaving water temperature ( C) Example : With ambient temperature of 2 C and relative humidity of 0%. If leaving water temperature is below 2 C, condensation on water piping will happen Dry bulb temperature ( C) Remark Refer to psychometric chart for more information. 2 If condensation is expected, installation of EKHBDP - drainpan kit must be considered. Part System Outline 27

6 General Outline: Altherma ESIE Part System Outline

7 ESIE Specifications Specifications Part 2. What Is in This Chapter? Introduction This chapter contains the following information: Technical specifications Electrical specifications Altherma This chapter contains the following specifications: Topic See page 2.2 Technical and Electrical Specifications for ERHQ0~06AAW 0 2. Technical and Electrical Specifications for EKHBH06AA*** and EKHBX06AA*** EKHBH06AB*** and EKHBX06AB*** 2. Technical and Electrical Specifications for EKSWW0~00V/Z2 EKHWS0~00*V/Z2 2. Technical and Electrical Specifications for EKSWWU0~00V EKHWSU0~00*V Technical and Electrical Specifications for EKSOLHWAV 8 Part System Outline 29

8 Specifications ESIE Technical and Electrical Specifications for ERHQ0~06AAW Technical specifications The table below contains the technical specifications. Specification Heating only type Reversible type ERHQ0AAW ERHQ0AAW ERHQ06AAW ERHQ0AAW ERHQ0AAW ERHQ06AAW indoor units Casing Dimensions Weight of unit Colour Material EKHBH06A B* EKHBH06A B* EKHBH06A B* Ivory white EKHBX06A B* Painted galvanised steel plate Packing Height 2 mm Width 980 mm Depth 20 mm Unit Height mm Width 900 mm Depth 20 mm Machine net weight (ERHQ*W*/ERHQ*W8*) Packed machine weight (ERHQ*W*/ERHQ*W8*) 08/0 kg 20/22 kg Weight of packing Material EPS, Carton, Wood, PE (straps) materials Weight 2 kg Heat exchanger Specifications Length 87 mm Nr. of rows 2 Fin pitch. mm Nr. of passes Face area. m² Nr. of stages 60 Empty tubeplate hole 0 EKHBX06A B* Tube type Hi-XSS(8) Fin Type WF fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Quantity 2 Air flow rate Cooling (nominal at 20 V) Heating Discharge direction Horizontal External static pressure (Max) - Motor Quantity 2 Model Brushless DC motor Position - Speed (nominal at 20 V) - number of steps 8 Speed (nominal at 20 V) - cooling Speed (nominal at 20 V) - heating EKHBX06A B* 780 rpm 780 rpm 780 rpm 760 rpm 760 rpm 760 rpm 760 rpm 760 rpm 760 rpm Output 70 W Drive Direct drive Compressor Quantity Motor Model JTG-VDYR@T Type Hermetically sealed scroll compressor Speed - Motor output 2200 W Starting method Inverter driven Crankcase heater W 0 Part System Outline

9 ESIE08-0 Specifications Specification Heating only type Reversible type indoor units ERHQ0AAW ERHQ0AAW ERHQ06AAW ERHQ0AAW ERHQ0AAW ERHQ06AAW EKHBH06A B* EKHBH06A B* EKHBH06A B* EKHBX06A B* EKHBX06A B* EKHBX06A B* Operation range Heating Min. -20 C DB Max. C DB Cooling Min. 0 C DB Max. 6 C DB Sanitary water Min. -20 C DB Max. C DB Sound level (nominal) Heating () Sound power 6 dba 6 dba 66 dba 6 dba 6 dba 66 dba Sound pressure () dba dba 2 dba dba dba 2 dba Cooling () Sound power 6 dba 66 dba 69 dba 6 dba 66 dba 69 dba Sound pressure () 0 dba 2 dba dba Sound level (night Heating Sound pressure 2 dba 2 dba dba 2 dba 2 dba dba quiet) Cooling Sound pressure dba dba 6 dba Refrigerant Type R0A Charge 2.9 kg Control Expansion valve (electronic type) Nr. of circuits Refrigerant oil Type Daphne FVC68D Charged volume.0 l Piping connections Liquid Quantity Type Flare connection Diameter (OD) 9.2 mm Gas Quantity Type Flare connection Diameter (OD).9 mm Drain Quantity Type Hole Diameter (OD) x26 / x8 Piping length Min. (2) m Max. 7 m Equivalent 9 m Chargeless 0 m Additional refrigerant charge See installation manual outdoor unit PW202- Installation height difference max. 0 m Max. interunit level difference - Heat insulation Both lquid and gas pipes Defrost method Pressure equalising Defrost control Sensor for outdoor heat exchanger temperature Capacity control method Inverter controlled Capacity control (%) Safety devices High pressure switch Fan motor thermal protector Fuse Standard accessories Item Tie wraps Quantity 2 Standard accessories Item Installation manual Quantity Notes () The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (2) Down to m with recharging of the outdoor unit. Refer to the installation manual of the outdoor unit. Part System Outline

10 Specifications ESIE08-0 Electrical specifications The table below contains the electrical specifications. Specification Heating only type Reversible type ERHQ0AAW ERHQ0AAW ERHQ06AAW ERHQ0AAW ERHQ0AAW ERHQ06AAW indoor units EKHBH06A B* EKHBH06A B* EKHBH06A B* Power supply Name W* Phase N~ Frequency 0 Hz Voltage 00 V Current Nominal running current Cooling Heating.8 A Starting current (cooling/heating) Zmax - Minimum S sc value - Maximum running current Cooling./ (ERHQ*W*/ERHQ*W8* ) Heating EKHBX06A B* EKHBX06A B* Recommended fuses 20 A Voltage range Minimum 60 V Maximum 0 V Wire connections For power supply Quantity Remark See installation manual outdoor unit PW202- For connection with Quantity hydro-box Remark See installation manual outdoor unit PW202- Power supply intake Outdoor unit only EKHBX06A B* 2 Part System Outline

11 ESIE08-0 Specifications 2. Technical and Electrical Specifications for EKHBH06AA*** and EKHBX06AA*** EKHBH06AB*** and EKHBX06AB*** Technical specifications The table below contains the technical specifications. Specification EKHBH* EKHBX* EKHBH06AA*/AB* EKHBH06AA*/AB* Outdoor units ERHQ0AA ERHQ0AA ERHQ06AA ERHQ0AA ERHQ0AA ERHQ06AA l/min.8 l/min 7.6 l/min Nominal input (indoor only without electric heater) 20 W Casing Colour RAL900 Material Epoxy polyester painted galvanised steel Dimensions Packing Height 22 mm Width 660 mm Depth 60 mm Unit Height () 922 mm Width 02 mm Depth 6 mm Weight of unit Machine net weigth kg Packed machine weight 6 kg Packing Material EPS, Wood, Carton, PP (straps) Weight 0 kg Main components Pump Type Water cooled Nr. of speed 2 Nominal ESP unit Cooling.9 kpa 9. kpa 6.8 kpa Nominal ESP unit Heating 2. kpa. kpa.0 kpa 2. kpa. kpa.0 kpa Power input 20 W Water side Type Brazed plate Heat exchanger Quantity Water volume.0 l Water flow rate Min. 6 l/min Water flow rate Nom Cooling (2) Water flow rate Nom. 2. l/min 0. l/min.9 l/min 2. l/min 0. l/min.9 l/min Heating () Water flow rate Max. Cooling Water flow rate Max. Heating Insulation material 8 l/min 8 l/min Polyurethane foam Expansion Volume 0 l vessel Max. water pressure bar Pre-pressure bar Water filter Diameter perforations mm Material Brass Water circuit Piping connections diameter -/ MBSP Piping -/ Safety valve bar Manometer Yes Drain valve / Fill valve Yes Shut off valve Yes Air purge valve Yes Total water volume (6). l Refrigerant Gas side diameter.9 mm ciruit Liquid side diameter 9.2 mm Sound level () Sound pressure 28 dba Sound power Part System Outline

12 Specifications ESIE08-0 Specification EKHBH* EKHBX* EKHBH06AA*/AB* EKHBH06AA*/AB* Outdoor units ERHQ0AA ERHQ0AA ERHQ06AA ERHQ0AA ERHQ0AA ERHQ06AA Operation range (ERHQ0** / AAV*) Operation range (ERHQ0** / AAW*) Ambient Cooling 0~6 C Heating -20~ C -20~ C Waterside Cooling ~22 C Heating () ~ C ~ C Ambient Cooling 0~6 C Heating (7) -2~ C -2~ C Waterside Cooling ~22 C () Heating ~ C ~ C Notes () With option kit EKHBDP installed: Height = 96 mm (2) Tamb C - LWE 7 C (DT = C) () DB/WB 7 C/6 C - LWC C (DT = C) () The sound pressure level is measured via a microphone at m from the unit. It is a relative value depending on the distance and acoustic environment. The sound pressure level mentioned is valid for pump medium speed. () C~2 C: BUH only, no Heatpump operation = during commissioning (6) Including piping + PHE + backup heater / excluding expansion vessel (7) -2 ~ -20 C: operation of heat pump possible, but no guarantee of capacity (if outdoor temperature < -2 C unit will stop) Electrical specifications Electric heater (optional) Voltage range Wiring connections The table below contains the electrical specifications. Type V 6V 6WN 6T 9WN 9T Power supply Phase ~ ~ ~ ~ ~ ~ () (2) Frequency 0 Hz Voltage 20 V 20 V 00 V 20 V 00 V 20 V Current Running current A 26 A 8.7 A. A A 22.6 A Zmax List No requirements Zmax (electric heater) + booster heater (EKSWW* models) No requirements Out of scope No requirements Out of scope Text j0. List No requirements Out of scope No requirements Out of scope Text j j0.09 Minimum 207 V 207 V 60 V 207 V 60 V 207 V Maximum 2 V 2 V 0 V 2 V 0 V 2 V For power supply backup heater For power supply connection to optional sanitary tank + Q2L For connection with RT Quantity of wires G G G G G G Type of wires Note () Note () Note () Note () Note () Note () Quantity of wires G Type of wires Note () and () Quantity of wires Note (7) Type of wires Note (7) For connection with AP For connection with M2S For connection with MS Quantity of wires Note (6) Type of wires Note () and () Quantity of wires G Type of wires Note () and () Quantity of wires G or G Type of wires Note () and () Part System Outline

13 ESIE08-0 Specifications Notes () Above mentioned power supply of the hydro-box is for the backup heater only. The switch box & pump of the hydro-box are supplied via the outdoor unit. Theoptional domestic warm water tank has a separate power supply. (2) Optional electric heater has 2 capacity steps except for the V model which has only one capacity step. () Select diameter and type according to national and local regulations. () For more details of the voltage range and current refer to installation manual EKHBH/X06A**. () Voltage: 20 V / Maximum current: 00 ma / Minimum 0.7 mm². (6) Depends on thermostat type, refer to installation manual EKHBH/X06A**. (7) Wire included in option EKSWW*/EKHWS*/EKHWE*. Part System Outline

14 Specifications ESIE Technical and Electrical Specifications for EKSWW0~00V/Z2 EKHWS0~00*V/Z2 Technical specifications Specification The table below contains the technical specifications. EKSWW0V EKHWS0*V EKSWW200V EKHWS0*V EKSWW00V EKHWS0*V EKSWW200Z2 EKHWS0*V EKSWW00Z2 EKHWS0*V Casing Colour Neutral white Material Epoxy-coated mild steel Dimensions Packing Height 90 mm 200 mm 60 mm 200 mm 60 mm Width 600 mm Depth 600 mm Unit Height 900 mm 0 mm 600 mm 0 mm 600 mm Width 80 mm Depth 80 mm Weight Machine weigth 7 kg kg 9 kg kg 9 kg Gross weight 0 kg 9 kg 6 kg 9 kg 6 kg Gross weight (EKSWW) 2 kg kg 66 kg kg 66 kg Packing Material EPS/Carton Weight kg kg kg kg kg Main components Tank Water volume 0 l 200 l 00 l 200 l 00 l Material Stainless steel (DIN.2) Max. temperature 8 C Max. water pressure 0 bar Insulation Material Polyurethane foam Insulation Min. thickness 0 mm Heat exchanger Quantity Material Stainless steel (DIN.0) Material (EKSWW) Duplex steel LDX 20 Booster heater Quantity Capacity kw Temperature sensor Cable length 2 m Piping connections Water inlet H/E Diameter / FBSP (inch) Water outlet H/E Diameter / FBSP (inch) Cold water in Diameter / FBSP (inch) Hot water out Diameter / FBSP (inch) Electrical specifications Specification The table below contains the electrical specifications. EKSWW0V EKHWS0*V EKSWW200V EKHWS0*V EKSWW00V EKHWS0*V EKSWW200Z2 EKHWS0*V EKSWW00Z2 EKHWS0*V Unit Power supply Phase ~ 2~ Frequency 0 Hz Voltage 20 V 00 V Nominal running current A 7. A Fuse Size 20 A Phase ~ 2~ 6 Part System Outline

15 ESIE08-0 Specifications 2. Technical and Electrical Specifications for EKSWWU0~00V EKHWSU0~00*V Technical specifications The table below contains the technical specifications. Specification EKSWWU0V EKHWSU0*V EKSWWU200V EKHWSU0*V EKSWWU00V EKHWSU0*V Casing Colour Neutral white Material Epoxy-coated mild steel Dimensions Packing Height 00 mm 280 mm 7 mm Width 600 mm Depth 600 mm Unit Height 0 mm 26 mm 7 mm Width 80 mm Depth 80 mm Weight Machine weigth 8 kg 6 kg 60 kg Gross weight kg 0 kg 6 kg Gross weight (EKHWS) kg 2 kg 67 kg Packing Material EPS/Carton Weight kg kg kg Main components Tank Water volume 0 l 200 l 28 l Material Stainless steel (DIN.2) Max. temperature 8 C Max. water pressure 0 bar Insulation Material Polyurethane foam Insulation Min. thickness 0 mm Heat exchanger Quantity Material Stainless steel (DIN.0) Material (EKHWS) Duplex steel LDX 20 Booster heater Quantity Capacity kw Temperature sensor Cable length 2 m Piping connections Water inlet H/E Diameter / FBSP (inch) Water outlet H/E Diameter / FBSP (inch) Cold water in Diameter / FBSP (inch) Hot water out Diameter / FBSP (inch) Electrical specifications The table below contains the electrical specifications. Specification EKSWWU0V EKHWSU0*V EKSWWU200V EKHWSU0*V EKSWWU00V EKHWSU0*V Unit Power supply Phase ~ Frequency 0 Hz Voltage 20 V Nominal running current A Fuse Size 20 A Phase ~ Part System Outline 7

16 Specifications ESIE Technical and Electrical Specifications for EKSOLHWAV Technical specifications The table below contains the technical specifications. Specification EKSOLHWAV Dimensions Packing Height 79 mm Width 0 mm Depth 29 mm Unit Height 770 mm Width 0 mm Depth 270 mm Weight of unit Machine weigth 8 kg Gross weight 9 kg Weight of packing Material Carton materials Weight kg Heat exchanger Type Brazed plate Pressure drop Solar side 2. kpa Maximum inlet temperature Solar side 0 C Heat exchange capacity Logarithmic mean temperature difference (LMTD) 00 W/K Pump Type water cooled Number of speeds Nominal ESP Heating - Power input Medium speed 6 W Water flow rate Min. - Max. - Nom. - Sound Sound pressure 27 dba Water circuit Piping connection diameter / F BSP Insulation material EPP Ambient temperature Max. C Min. C K Electrical specifications The table below contains the electrical specifications. Specification EKSOLHWAV Unit Power supply Phase ~ Frequency 0 Hz Voltage V Nominal running current Not applicable Fuse Size Not applicable Phase Not applicable Wiring connections For power supply Quantity Not applicable Remark Not applicable For connection Quantity Not applicable with indoor Remark Not applicable Voltage range Power supply intake Minimum -0% Maximum +0% indoor unit 8 Part System Outline

17 ESIE08-0 Functional Diagrams Functional Diagrams Part. What Is in This Chapter? Introduction Functional diagrams This chapter contains the following information: Overview complete system Electrical connection diagram Pipe connection diameters. This chapter contains the following functional diagrams: Topic See page.2 Complete System 0. Electrical Connection Diagram 2. Pipe Connection Diameters Part System Outline 9

18 Functional Diagrams ESIE Complete System IRT t > IRT t > M 2 IRT t > : COOLING (EKHBX) : HEATING (EKHBX + EKHBH) 2 27 EVAPORATOR CONDENSOR M T FCU T OR2T ORT ORT ORT ORT OR6T COOLING HEATING p > IR2T t > p < M M t > IRT M 0 Part System Outline

19 ESIE08-0 Functional Diagrams Components The table below contains the different components of the functional diagrams. No. Name Heat exchanger (Outdoor unit) 2 Filter (Outdoor, refrigerant) Expansion valve Liquid stop valve with service port Gas stop valve with service port 6 Pressure sensor (Outdoor unit) 7 -way valve ON: heating 8 High pressure switch discharge pipe (Outdoor unit) 9 Compressor 0 Accumulator Service port /6 2 Propeller fan Heat exchanger PME (hydro-box) Backup heater Expansion vessel 6 Drain valve 7 Manometer 8 Air purge valve 9 Pressure relief valve 20 Pump 2 Flow switch 22 Shut off valve with drain/fill valve 2 Filter (hydro-box, water) 2 -way valve for sanitary water tank 2 SWW tank 26 2-way valve to block heating supply to tank heat exchanger (EKSWWU only) 27 Booster heater 28 By-pass valve 29 2-way valve for cooling mode to block floor heating loops OR Outdoor air temperature thermistor T OR2 T OR T OR T OR T OR6 T IRT IR2T IRT IRT IRT Discharge pipe thermistor (Outdoor unit) Suction pipe thermistor (Outdoor unit) Heat exchanger thermistor (Outdoor unit) Heat exchanger middle thermistor (Outdoor unit) Liquid refrigerant thermistor (Outdoor unit) Outlet water Heatexchanger thermistor (hydro-box) Outlet water Backup heater thermistor (hydro-box) Liquid refrigerant thermistor (hydro-box) Inlet water thermistor (hydro-box) Sanitary water tank thermistor (hydro-box) Part System Outline

20 Functional Diagrams ESIE08-0. Electrical Connection Diagram Power supply unit power supply: 20V + earth backup heater power supply (/6/9kW): 00V or 20V + earth Optional power supply: booster heater power supply (kw): 00V or 20V + earth Optional parts DHW TANK Electrical connection diagram Altherma (0/0/06 class) core core or core XM:LñNñearth <0m:Gx. >0m:Gx2. Standard parts OUTDOOR UNIT XM:ñ2ññearth core XM:ñ2ññearth XM:LñL2ñLñNñearth XM:LñNñearth Applicable for the following models: OUTDOOR UNIT : ERHQ0/0/06AAV INDOOR UNIT : EKHBH/X06AAV EKHBH/X06AA6V EKHBH/X06AA6W EKHBH/X06AA6T EKHBH/X06AA9W EKHBH/X06AA9T For more details please check unit wiring diagram QLñQT CLIXON THERMOSTAT 2ñWAY VALVE Power supply booster heater Q2L ñ CLIXON booster heater RT ñ Thermistor water temperature 2way valve 2 core 2x0.7 XM X7M F2B 20V X6M core Gx2. 20V or 00V 2 core signal Thermistor cable NOTE : min. distance to power cable = cm ONLY FOR EKSWWU*V XM:ñ2ñearth X2M:ñ2ññ NO valve: X2M:6ñ7 X2M:ñ NC valve: X2M:ñ7 spring return X2M: 9ñ0 X9A (PCB AP) SPST: X2M: 8ñ9ñ0 INDOOR UNIT user interface core 20V core 20V 2 or core 20V Field supply Room thermostat AP 2way valve M2S (EKHBX units) for cooling mode way valve MS (when EKSWW is installed) selection sanitaryñfloorheating 2 Part System Outline

21 ESIE08-0 Functional Diagrams. Pipe Connection Diameters Outdoor units The table below contains the refrigerant pipe connection diameters. Model Gas pipe (flare) Liquid pipe (flare) ERHQ0AAV*/W*.9 mm 9.2 mm ERHQ0AAV*/W* ERHQ06AAV*/W* hydro-box hydro-box + water side The table below contains the refrigerant pipe connection diameters. Model Gas pipe (flare) Liquid pipe (flare) EKHBH06A*.9 mm 9.2 mm EKHBX06A* The table below contains the water inlet/outlet connection diameters. Model Inlet pipe Outlet pipe EKHBH06A* EKHBX06A* EKSWW(U)0 EKSWW(U)200 -/ inch (MBSP) / inch (FBSP) 2 -/ inch (MBSP) / inch (FBSP) EKSWW(U)00 EKHWS(U)0 EKHWS(U)200 / inch (FBSP)² / inch (FBSP)² EKHWS(U)00 EKHWE0 Rp / (female) EKHWE200 Rp / (female) EKHWE00 : MBSP = male British standard pipe 2: FBSP = female British standard pipe Hot + cold water side Model Cold water Hot water Re-circulation connection EKHWS(U)0 / (FBSP)² EKHWS(U)200 EKHWS(U)00 / (FBSP)² / (FBSP)² Part System Outline

22 Functional Diagrams ESIE08-0 Model Cold water Hot water Re-circulation connection EKHWE0 / / / EKHWE200 EKHWE00 Part System Outline

23 ESIE08-0 Piping Diagrams Piping Diagrams Part. What Is in This Chapter? Introduction Piping diagrams This chapter contains the following information: Piping diagrams This chapter contains the following piping diagrams: Topic See page.2 Piping Diagram for ERHQ0~06AAV* 6. Piping Diagram for EKHBH(X)06AA***/EKHBH(X)06AB*** 0. Piping Diagram for EKSWWU0~00V EKHWSU0~00*V 2 Part System Outline

24 Piping Diagrams ESIE Piping Diagram for ERHQ0~06AAV* p < 6 p > EKHB*06* 0 2 INDOOR UNIT 2 OUTDOOR UNIT HEATING COOLING 6 Part System Outline

25 ESIE08-0 Piping Diagrams. Piping Diagram for ERHQ0~06AAW* Part System Outline 7

26 Piping Diagrams ESIE08-0 Components The table below contains the different components of the functional diagrams. No. Name Heat exchanger - 2 Service port /6 - Compressor MC Accumulator - Pressure sensor SNPH 6 High pressure switch SPH 7 -way valve YS 8 Filter - 9 Electronic expansion valve YE 0 Field piping φ9. C 220T-0 - Field piping φ.9 C 220T-0-2 Stop valve (with service port /6 flare) - Crank case heater EHC Fan motor MF-M2F Injection valve YS 6 Capillary tube - R T Thermistor (AIR) R2 T R T R T R T R6 T Thermistor (Discharge) Thermistor (suction) Thermistor (heat exchanger) Thermistor (heat exchanger middle) Thermistor (liquid) Symbols The table below contains the different symbols used on the functional diagrams. Symbol Name Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 8 Part System Outline

27 ESIE08-0 Piping Diagrams Caution for flare connection Refer to table below for correct flare dimensions and tightening torques. Too high tightening force may cause refrigerant leak because of flare cracking: Piping size Flare nut tightening torque A dimensions for processing flares (mm) Flare shape φ6..2~7.2 N m (~76 kgf cm) 8.7~9. φ9. 2.7~9.9 N m (~07 kgf cm) 2.8~.2 90 ±0. A ±2 φ2.7 9.~60. N m (0~66 kgf cm) 6.2~6.6 R=0.~0.8 φ.9 6.8~7. N m (60~770 kgf cm) 9.~9.7 φ ~8.6 N m (989.8~208 kgf cm) 2.6~2.0 When connecting the flare nut, apply refrigerating machine oil to the flare (inside and outside) and first screw the nut or turns by hand. Coat the indicated surfaces using ether or ester oil: After completing the installation, carry out an inspection of the piping connections by pressure test using nitrogen. Part System Outline 9

28 Piping Diagrams ESIE08-0. Piping Diagram for EKHBH(X)06AA***/EKHBH(X)06AB*** WATER SIDE 0 9 FIELD INSTALLATION R2T t > RT t > EVAPORATOR CONDENSOR REFRIGERANT SIDE REFR. OUT REFR. IN 2 2 FIELD INSTALLATION RT t > RT t > REFR. IN REFR. OUT 2 : COOLING (EKHBX) : HEATING (EKHBX + EKHBH) 0 Part System Outline

29 ESIE08-0 Piping Diagrams Components Symbols The table below contains the different components of the functional diagrams. No. Name Water outlet 2 Shut off valve with drain/fill valve Flowswitch Pump Back-up heater 6 Blow off 7 Safety valve 8 Air purge 9 Pressure gauge 0 Expansion vessel Drain 2 Plate heat exchanger Filter Water inlet R Outlet water heat exchanger thermistor T R2 T R T R T Outlet water backup heater thermistor Refrigerant liquid side thermistor Inlet water thermistor The table below contains the different symbols used on the functional diagrams. Symbol Name Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe Part System Outline

30 Piping Diagrams ESIE08-0. Piping Diagram for EKSWWU0~00V EKHWSU0~00*V OVERVIEW FIELD INSTALLATION (DELIVERED WITH INDOOR UNIT) FIELD SUPPLY 2 M MS OUTDOOR INDOOR LOAD WATER RETURN WATER FLOW OPTION SANITARY WARM WATER TANK OPTION SANITARY WARM WATER TANK WATER RETURN WATER FLOW WATER MAIN OUT WATER MAIN IN TPRV ( * ) ( * ) 9 ( * ) 0 ( * ) YS EKSWWU* t > RT ( * ) 6 ( * ) 7 ( * ) ( * ) 8 ( * ) : FIELD INSTALLATION DELIVERED WITH EKUSWW KIT 2 Part System Outline

31 ESIE08-0 Piping Diagrams Components Symbols The table below contains the different components of the functional diagrams. No. Name Shut off valve 2 -way motorized valve (MS) (****) 2-way solenoid valve (YS) (*) (***) Drain valve (*) (**) T-piece (*) (**) 6 Tundish (*) (**) 7 Expansion vessel (*) (**) 8 T-piece (*) (**) 9 Expansion relief valve (*) (**) 0 T-piece (*) Pressure reducing valve with integrated non return valve line strainer (*) (**) R Domestic hot water thermistor T (*): Field installation delivered with EKUSWW kit / EKUHWA kit (**): Field installation delivered with EKUHWB kit (***): Field installation delivered with EKUHW2B kit (only with EKSOLHWAV) (****): Field installation: - EKSWWU*: field supplied - EKHWSU*A*: field supplied - EKHWSU*B*: delivered with EKHWSU*B* The table below contains the different symbols used on the functional diagrams. Symbol Name Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe Part System Outline

32 Piping Diagrams ESIE08-0 Part System Outline

33 ESIE08-0 Switch Box Layout Switch Box Layout Part. What Is in This Chapter? Introduction Altherma This chapter shows the switch box components. This chapter contains the following switch box layouts: Topic See page.2 Switch Box Layout for ERHQ0~06AAV 6. Switch Box Layout for EKHBH(X)06A*** 8. Switch Box Layout for EKSWW***V/Z Switch Box Layout for EKSWWU***V 6 Part System Outline

34 Switch Box Layout.2 ESIE08-0 Switch Box Layout for ERHQ0~06AAV The illustration below shows the outdoor switch box layout: AP A2P AP AP AP A2P XM AP AP XM 6 Item Description AP Printed circuit board (control) A2P Printed circuit board (service) AP Printed circuit board (noise filter) AP Printed circuit board (communication) XM Terminal strip Part System Outline

35 ESIE08-0 Switch Box Layout. Switch Box Layout for ERHQ0~06AAW The illustration below shows the outdoor switch box layout. Item AP A2P AP AP XM Description Printed circuit board (control) Printed circuit board (service) Printed circuit board (noise filter) Printed circuit board (communication) Terminal strip Part System Outline 7

36 Switch Box Layout. ESIE08-0 Switch Box Layout for EKHBH(X)06A*** The illustration below shows the switch box layout: TR KM KM K2M TR KM KM K2M KM AP KM AP FB F2B FB F2B KM FU2 8 XM X2M XM XM KM FU2 XM X2M XM XM Part System Outline

37 ESIE08-0 Switch Box Layout Item Description KM Contactor backup heater step K2M Contactor backup heater step 2 KM Contactor booster heater KM Pump relay KM Safety contactor backup heater step /2 XM Terminal strips: power supply backup heater + in/outdoor wiring (2) X2M Terminal strips: field wiring XM Terminal strips: booster heater supply to contactor XM Terminal strips: from contactor to booster heater FB Fuse backup heater F2B Fuse booster heater AP Printed circuit board (main) TR Transformer (220 V/2 V) FU2 Fuse pump Part System Outline 9

38 Switch Box Layout ESIE08-0. Switch Box Layout for EKSWW***V/Z2 The illustration below shows the switch box layout: Item Description XM Terminal strip nr -2: power supply booster heater Q2L Thermal protector booster heater: connection nr - EH Booster heater kw 20 V () () Remark: Internal connection of Booster heater kw 00 V is slightly different. 60 Part System Outline

39 ESIE Switch Box Layout Switch Box Layout for EKSWWU***V The illustration below shows the switch box layout: QL Q2L XM QT? Item Description XM Terminal strip nr -2: power supply booster heater Q2L Thermal protector booster heater: connection nr -2/- EH Booster heater kw 20 V () QT Thermostat sanitary warm water tank QL Thermal protector sanitary warm water tank connection nr -2/- Part System Outline 6

40 Switch Box Layout ESIE Part System Outline

EEDEN technical data ERHQ AA

EEDEN technical data ERHQ AA EEDEN08-70 technical data Altherma Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil

More information

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW EEDEN07-721 technical data Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Daikin s unique position as a manufacturer of air conditioning

More information

EEDEN technical data ERHQ AA. Altherma. Altherma

EEDEN technical data ERHQ AA. Altherma. Altherma EEDEN08-720 technical data ERHQ0-06AA Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement

More information

EEDEN technical data EKSOLHWAV1

EEDEN technical data EKSOLHWAV1 EEDEN08-720 technical data Altherma EKSOLHWAV Altherma Solar Kit Features S o l a r K i t A l t h e r m a E K S O L H W A V S o l a r K i t 2 Specifications 2- TECHNICAL SPECIFICATIONS EKSOLHWAV Dimensions

More information

TABLE OF CONTENTS EKHWS

TABLE OF CONTENTS EKHWS Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS TABLE OF CONTENTS EKHWS 1 Features............................................................ 68 2 Specifications......................................................

More information

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL EEDEN08-70 technical data Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Daikin s unique position as

More information

Service Manual ESIE Altherma. - Outdoor unit - ERHQ011~016AAV3* - ERHQ011~016AAW1*

Service Manual ESIE Altherma. - Outdoor unit - ERHQ011~016AAV3* - ERHQ011~016AAW1* ESIE08-0 Service Manual Altherma - Outdoor unit - ERHQ0~06AAV* - ERHQ0~06AAW* - Hydro-box - EKHBH(X)006*** - Remote Alarm / Operation signal - EKRPHB - Domestic hot water tank - EKSWW0~00V/Z2 - EKSWWU0~00V

More information

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW50-300 Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW50-300 The present publication is drawn up by way of information only and

More information

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL EEDEN08-70 technical data Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Daikin s unique position as

More information

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3 Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EDHQ-BB6V3 Monobloc without bottom plate heater EDHQ-BB6V3 TABLE OF CONTENTS EDHQ-BB6V3 Features.............................................................

More information

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1 Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EBLQ-BB6W Monobloc with bottom plate heater EBLQ-BB6W TABLE OF CONTENTS EBLQ-BB6W Features.............................................................

More information

EEDEN technical data. Altherma TM

EEDEN technical data. Altherma TM EEDEN09-720 technical data Altherma TM Altherma TM Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrige-rants has led to its close involvement in environmental

More information

TABLE OF CONTENTS ERSQ-AAY1

TABLE OF CONTENTS ERSQ-AAY1 Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................

More information

TABLE OF CONTENTS ERHQ BAV3

TABLE OF CONTENTS ERHQ BAV3 TABLE OF CONTENTS ERHQ006-016BAV3 1 Features........................................................... 134 2 Specifications..................................................... 135 Nominal Capacity and

More information

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

DACA-EEDEN technical data. Engineering Data. DaikinAltherma technical data Engineering Data DaikinAltherma Daikin Altherma Engineering Data Part 1: Overview 1. Daikin Altherma Overview... 1 1.1 Daikin Altherma Split System...1 1.2 Daikin Altherma Monobloc System...2

More information

DESIGN MANUAL Version 1.0

DESIGN MANUAL Version 1.0 DESIGN MANUAL 2009 Version 1.0 TABLE OF CONTENTS Topic Type Page 1. Introduction 5 2. System Design 6 2.1 Components 6 2.2 Design Guidelines 7 2.2.1 Total Heat Demand 7 2.2.2 Inclusion of power supply

More information

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1 Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CW Daikin Altherma low temperature split ERLQ-CW TABLE OF CONTENTS ERLQ-CW Features.............................................................

More information

TABLE OF CONTENTS RMXS-E8V1B

TABLE OF CONTENTS RMXS-E8V1B Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................

More information

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6 EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Sound pressure level Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Hydraulic components Anti freeze heater (optional) W 75 75 75 Expansion

More information

Heating. Technical Data EEDEN ERRQ-AY1

Heating. Technical Data EEDEN ERRQ-AY1 Heating Technical Data EEDEN3-726 ERRQ-AY Daikin Altherma high temperature split ERRQ-AY TABLE OF CONTENTS ERRQ-AY Features............................................................. 2 2 Specifications.......................................................

More information

TABLE OF CONTENTS EDLQ AA6V3

TABLE OF CONTENTS EDLQ AA6V3 Monobloc EDLQ0-06AA6V3 TABLE OF CONTENTS EDLQ0-06AA6V3 Features............................................................. 2 2 Specifications....................................................... 3

More information

TABLE OF CONTENTS EBLQ01-016AA6V3

TABLE OF CONTENTS EBLQ01-016AA6V3 Monobloc EBLQ0-06AA6V TABLE OF CONTENTS EBLQ0-06AA6V Features............................................................. 2 2 Specifications....................................................... Nominal

More information

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A Air Conditioners Technical Data Heating only hydrobox for VR V E E D E N 1 1-2 0 4 HXHD-A Air Conditioners Technical Data Heating only hydrobox for VR V E E D E N 1 1-2 0 4 HXHD-A TABLE OF CONTENTS HXHD-A

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWS50BV EKHWS00BV EKHWS00BV EKHWS00BZ EKHWS00BZ 4 5 6 x x x 4x x + x 00 7 05 0 45 5 400 5 6 00 /4" FBSP 6 H 0 H4 H 0 H 0

More information

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB INSTALLATION MANUAL Domestic hot water tank with option kit for air to EKHWSU50BV EKHWSU00BV EKHWSU00BV EKUHWB EKUHWWB EKHWSU50BV EKHWSU00BV EKHWSU00BV EKUHWB EKUHWWB CONTENTS Page INTRODUCTION Introduction...

More information

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700

More information

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................

More information

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A Air Conditioning Technical Data Low temperature hydrobox for VRV EEDEN3-204 HXY-A Indoor Unit Low temperature hydrobox for VRV HXY-A TABLE OF CONTENTS HXY-A Features.............................................................

More information

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN AZQS-BV1 Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data RZASG-MV1

Air Conditioning Technical Data RZASG-MV1 Air Conditioning Technical Data RZASG-MV1 Outdoor Unit RZASG-MV1 TABLE OF CONTENTS RZASG-MV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems RZQ B8W1B Split Sky Air

technical data air conditioning systems RZQ B8W1B Split Sky Air technical data RZQ00-25-40B8WB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its

More information

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1 Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Single Unit Air cooled chiller EUWA-KBZW TABLE

More information

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8 Air Conditioning Technical Data High temperature hydrobox for VRV EEDEN15-204 Indoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1 Air Conditioning Technical Data EEDEN-00 RZQSG-L(/8)V Outdoor Unit RZQSG-L(/8)V TABLE OF CONTENTS RZQSG-L(/8)V Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data RZAG-MV1

Air Conditioning Technical Data RZAG-MV1 Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Service Manual. Air Cooled Refrigeration Condensing Unit

Service Manual. Air Cooled Refrigeration Condensing Unit SiENBE28-901 Service Manual Air Cooled Refrigeration Condensing Unit LRLEQ5AY1(E) LRLEQ6AY1(E) LRLEQ8AY1(E) LRLEQ10AY1(E) LRLEQ12AY1(E) LRLEQ15AY1(E) LRLEQ20AY1(E) LRMEQ5AY1(E) LRMEQ6AY1(E) LRMEQ8AY1(E)

More information

EEDEN technical data EKRTR. Altherma. Altherma

EEDEN technical data EKRTR. Altherma. Altherma EEDEN08-720 technical data EKRTR Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air EEDEN09-00 technical data RZQS-DV air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1 Air Conditioning Technical Data EEDEN3-00 RZQSG-L(8)Y Outdoor Unit RZQSG-L(8)Y TABLE OF CONTENTS RZQSG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

Split Type System. Air to Water Heat Pump

Split Type System. Air to Water Heat Pump Split Type System Air to Water Heat Pump EXPERTISE AND INNOVATION Daikin Altherma offers complete flexibility for new construction and deep energy refurbishment projects. Using a low temperature hydronic

More information

Air Conditioning Technical Data AZAS-MY1

Air Conditioning Technical Data AZAS-MY1 Air Conditioning Technical Data AZAS-MY1 Outdoor Unit AZAS-MY1 TABLE OF CONTENTS AZAS-MY1 1 Features............................................................. 2 2 Specifications.......................................................

More information

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air EEDEN08-00 technical data RZQS7-40C7VB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has

More information

TABLE OF CONTENTS EKHTS-A

TABLE OF CONTENTS EKHTS-A TABLE OF CONTENTS EKHTS-A 1 Features........................................................... 408 2 Specifications..................................................... 409 Technical Specifications...........................................

More information

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F) Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.

More information

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air EEDEN09-00 technical data RZQ-DV air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to

More information

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H) Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.

More information

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1 Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

PUHZ-SHW140YHA PUHZ-SHW230YKA

PUHZ-SHW140YHA PUHZ-SHW230YKA 1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate

More information

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data FTXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note) History List Version Date Update Information 1.0 15.02.27-2015 New EHS SPLIT TDB Released. (Modify the Spec Note) 1.1 15.03.06 1.2 15.04.06 - Modify : Note(Spec, Capacity Table) / Electric Diagram / OD

More information

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air technical data FHYP-B Ceiling Suspended Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T Air Conditioning echnical Data VRV IV heat recovery EEDEN14-0_4 REYQ- ABLE OF CONENS REYQ- 1 Features............................................................. 2 2 Specifications.......................................................

More information

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52 Error Codes: Outdoor Units Error Codes: Outdoor Units Part. What Is in This Chapter? Introduction Overview In the first stage of the troubleshooting sequence, it is important to correctly interpret the

More information

EHS. EHS (Mono, LT, 50Hz)

EHS. EHS (Mono, LT, 50Hz) EHS EHS (Mono, LT, 50Hz) I. Products 1. Nomenclature.... 5 2. Line-up....... 7 1. Specification...... 9 2. Capacity Tables..... 13 3. Dimensional Drawings............. 19 4. Piping Diagrams..... 23 5.

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only ED 40-437 Packaged Air Conditioners Duct Connection Type [50Hz] (Middle Static Pressure Application) FDMG-AV1(S) Series Cooling Only ED40-437 Duct Connection Type Middle Static Pressure Application [50Hz]

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air technical data RR-B8V3B_RR-B8WB Pair, Twin, Triple Application air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors

More information

technical data air conditioning systems Indoor Units FBQ-C7VEB

technical data air conditioning systems Indoor Units FBQ-C7VEB technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Air Conditioners. Technical Data FBQ-C

Air Conditioners. Technical Data FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz Service Manual RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz R-410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi 1.2 PREFACE...x Part 1 General Information... 1 1. Model Names of Indoor/Outdoor

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

Air-to-Water Hydromodule + Tank WH-UX12FE5 WH-UD12FE5 WH-UD16FE5. Destination Europe WARNING

Air-to-Water Hydromodule + Tank WH-UX12FE5 WH-UD12FE5 WH-UD16FE5. Destination Europe WARNING Order : PAPAMY420CE Air-to-Water Hydromodule + Tank Indoor Unit WH-ADC26G6E5 Outdoor Unit WH-UX09FE5 WH-UX2FE5 WH-UD2FE5 WH-UD6FE5 Destination Europe WARNING This service information is designed for experienced

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E Air Conditioning Technical Data Multi model application EEDEN1-100 MXS-E TABLE OF CONTENTS MXS-E 1 Features............................................................. 2 2 Specifications.......................................................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL DTW_3SP001E_03 DESIGN & TECHNICAL MANUAL High power series ( 3 phase type ) FUTURE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS 3 PHASE TYPE : WO K112LAT, WO K140LAT, WO

More information

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz 201806 Engineering Data RXYQ-TAYCU, 575 V Heat Pump 60 Hz RXYQ-TAYCU (575 V, 60 Hz) 1. Features and Benefits...3 2. Nomenclature...4 3. Model Names of Indoor Unit and Outdoor Unit...7 3.1 Outdoor Units...7

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) 6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw. Quiet operation Low speed fans All year round operation Cooling capacity : 25 to 165 kw Cooling only USE The offers a solution to both heating and cooling applications encountered in the public, tertiary

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components.

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTLLTION ND OPERTION MNUL 1 4 EKHW*150* EKHW*00* EKHW*150* 4 5 EKHW*00+00* 5 10 1 1 1 9 11 19 19 EKHW*150* EKHW*00* EKHW*00* 1 Installation and operation manual CONTENTS Page INTRODUCTION Introduction...1

More information