Food Service Technology Center
|
|
- Rhoda Bailey
- 5 years ago
- Views:
Transcription
1 Food Service Technology Center Hobart PW10eR Electric Pot and Pan Door-Type Dishwashing Machine Test Report Application of ASTM Standard Test Method F & F February 2016 Prepared by: Rich Swierczyna Fisher-Nickel, Inc. Contributors: Rodney Davis Fisher-Nickel, Inc. Prepared for: Pacific Gas and Electric Company Customer Energy Efficiency Programs PO Box San Francisco, California Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. 2016
2 Food Service Technology Center Background The information in this report is based on data generated at the Pacific Gas and Electric Company (PG&E) Food Service Technology Center (FSTC). Dedicated to the advancement of the foodservice industry, The FSTC has focused on the development of standard test methods for commercial foodservice equipment since The primary component of the FSTC is a 10,000 square-foot laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, equipment setup and storage areas, and a state-of-the-art demonstration and training facility. The FSTC Energy Efficiency for Foodservice Program is funded by California utility customers and administered by PG&E under the auspices of the California Public Utilities Commission (CPUC). California customers are not obligated to purchase any additional services offered by the contractor. Policy on the Use of Food Service Technology Center Test Results and Other Related Information Fisher-Nickel, Inc. and the FSTC do not endorse particular products or services from any specific manufacturer or service provider. The FSTC is strongly committed to testing foodservice equipment using the best available scientific techniques and instrumentation. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC. FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws. Disclaimer Copyright 2016 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. Reproduction or distribution of the whole or any part of the contents of this document without written permission of FSTC is prohibited. Results relate only to the item(s) tested. Neither, Fisher- Nickel, Inc., PG&E nor any of their employees, or the FSTC, make any warranty, expressed or implied, or assume any legal liability of responsibility for the accuracy, completeness, or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately-owned rights, including but not limited to, patents, trademarks, or copyrights. Reference to specific products or manufacturers is not an endorsement of that product or manufacturer by Fisher-Nickel, Inc., the FSTC, or PG&E. In no event will Fisher-Nickel, Inc. or PG&E be liable for any special, incidental, consequential, indirect, or similar damages, including but not limited to lost profits, lost market share, lost savings, lost data, increased cost of production, or any other damages arising out of the use of the data or the interpretation of the data presented in this report. Retention of this consulting firm by PG&E to develop this report does not constitute endorsement by PG&E for any work performed other than that specified in the scope of this project. Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (CPUC). It does not necessarily represent the views of the CPUC, its employees, or the State of California. The CPUC, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the CPUC nor has the CPUC passed upon the accuracy or adequacy of the information in this report. Revision History Revision num. Date Description Author(s) 0 Feb 2016 Initial Release R. Davis Page 2 of 17
3 Contents Page Equipment Description. 4 Test Location 4 Ventilation. 4 Test Instrumentation Inventory.. 5 FSTC Test Report: Results.. 6 Additions, Deviations, and Exclusions 12 Manufacturer Specifications Sheet Report Certification.. 17 Page 3 of 17
4 Equipment Description Test Work Order Number (TWO) Manufacturer Model Serial Number Generic Equipment Type Rated Input Construction Controls Hobart PW10eR H5334 Electric Single Rack, Door-Type Pot and Pan Dishwashing Machine 18.8 kw External Dimensions (W x D x H) 34.9" x 37.2" x 88.5" Custom Settings (if any) Stainless Steel tank and chamber, door, frame, legs and adjustable feet. Removeable stainless steel scrap screens and scrap basket Interface controls with digital cycle/temperature display None Test Location All testing was performed under controlled conditions in the FSTC laboratory facilities at Alcosta Blvd., Suite 101, San Ramon, CA Ventilation FSTC researchers installed the equipment on a tiled floor under a four-foot deep canopy hood, which operated at a nominal exhaust rate of 300 cfm per linear foot. The hood was mounted six feet, six inches above the floor, with at least six inches of clearance between the vertical plane of the equipment and the hood s edge. Page 4 of 17
5 Test Instrumentation Inventory Description (ID) Manufacturer Model Measurement Range Resolution Calibration Date Next Calibration Water Meter Seametrics SEB gpm gal Validated on Validated (SN# ) 09/26/2015 as needed Electric Meter (ALC301) Electro Industries Shark A 7.5 Wh 02/24/ /24/2016 DAQ Pulse (ALC312) National Instruments FP-CTR ,000 pulse/s 1 pulse 08/12/ /12/2016 DAQ Temp (ALC312) National Instruments FP-TC F 0.1 F 08/12/ /12/2016 Humidity Sensor General Eastern Hygro M4-DP F 0.1 F 08/18/ /18/2016 (CKVLY1006) Humidity Sensor General Eastern Hygro M4-DP F 0.1 F 08/18/ /18/2016 (CKVLY1007) Press. Transducer Setra c inwc inwc 02/17/ /17/2016 (CKVLF607) Press. Transducer Setra c inwc inwc 02/26/ /26/2016 (CKVLF602) Press. Transducer Setra c mbar mbar 02/13/ /13/2016 (CKVLF601) Thermocouple Inventory Set Number Validation Date 10 09/16/2015 Holding Equipment Inventory Description (ID) Manufacturer Model N/A N/A N/A Page 5 of 17
6 Purpose of Testing This testing determined the energy input rate and idle energy of the dishwashing machine and booster heater as well as water consumption, and washing capacity of racks of 3 pans using ASTM F Testing of the dishwashing machine also included application of ASTM F for heat gain to space performance. Energy Input Rate Dishwashing Booster Heater machine Voltage (V) Rated Energy Input Rate (kw) Measured Energy Input Rate (kw) Difference (%) Tank Fill Wash Tank Rated Capacity (gal) 21 Wash Tank Fill (gal) 21.3 Wash Tank Fill Time (min) 5.7 Idle Rate Active Tank Idle Energy Rate (kw) a 1.0 Booster Idle Energy Rate (kw) 0.1 Average Wash Tank Temperature ( F) 172 a tank heater automatically turns off after 90 minutes of inactivity Wash Test Results b Test Time (min) 48.9 Recovery Time (min) 0 Washing Energy Rate (kw) 7.05 Booster Energy Rate (kw) 0.84 Wash Energy Usage Per Rack (Wh) ± 3.3 Boost Energy Usage Per Rack (Wh) 98.1 ± 6.5 Water Consumption Per Rack (gal) 1.6 ± 0.0 Production Capacity (racks of pans/h) c 8.6 ± 0.0 b based on a minimum of three test replicates. Hobart PW10eR Ventless Door-Type Pot and Pan Dishwashing machine Hobart WWS, Inc. 701 S Ridge Avenue Troy, OH c using a 6 minute wash cycle setting. Page 6 of 17
7 Pan Wash Test Run #1 Run #2 Run #3 Test Time (min) Batch Recovery Time (min) Booster Heater Energy Consumption (kwh) Wash Tank/Controls (kwh) Water Consumed (gal) Total Energy/Test (kwh) Total Energy/Rack (kwh) Number of Racks Lbs. of Pans (lb) Total Pan Count Booster Energy Rate (kw) Wash Tank Energy Rate (kw) Total Energy Rate (kw) Cycle Rate (racks/h) Cycle Rate (Pans/h) Water Rate (gal/h) Water/Rack (gal) Average Supply Temp ( F) Average Wash Tank Temp ( F) Final Rinse Temp ( F) Ambient Temp ( F) Minimum Wash Tank Temp ( F) Page 7 of 17
8 Heat Load Tests These tests determined the heat load to the space from the Hobart PW10eR heat recovery hot water sanitizing dishwashing machine. The heat load to space is divided into two components: the convective heat that rises as hot air and steam from the machine and the radiation that is emitted by the hot surface of the machine by virtue of the temperature and emissivity. Convective heat can be further broken down into latent and sensible components to separate the dehumidification load on the space cooling system. For un-hooded appliances such as heat recovery dishwashing machines, both components load the kitchen space. The radiation is typically felt directly on the skin and through the clothing of the operator, whereas the convective heat usually circulates within the space and should be absorbed by the kitchen HVAC system. The calculations used to determine the amount of convective heat load from the dishwashing machine were derived by applying existing standards. These standards included ASTM F Standard Test Method for Performance of Single Rack, Door-Type Commercial Dishwashing Machines and ASTM F Standard Test Method for Heat Gain to Space Performance of Commercial Kitchen Ventilation/Appliance Systems. The test set up included the dishwashing machine operating under a canopy hood that exhausted outside the laboratory. The dry bulb temperatures, dew point temperatures, and airflow rates were measured for the exhaust and makeup air streams. From these measurements, the enthalpy and heat loads were calculated and averaged over each test period. The hood operated at a nominal exhaust rate of 1,700 cfm in order to ensure complete capture and containment of the thermal plume. Capture and containment of the effluent was visually verified using a Schlieren optical system. The lab was airtight for the heat gain tests and a makeup fan provided low velocity air (< 60 fpm) to the room through floor standing displacement diffusers. The makeup flow rate was balanced to maintain a pressure differential between the inside and the outside of the lab no greater than 0.01 inches of water throughout any heat gain test. The laboratory energy balance is shown below. The calculations that were applied to determine the results are shown in the subsequent equations. Page 8 of 17
9 Flow Measurement Primary Makeup Air Exhaust Air Qexhaust tdb-exhaust tdpt-exhaust E exhaust E radiation Canopy Hood Econvective E mua Qmua tdb-mua Eappliance tdpt-mua Ewater-out Ewater-in Energy Balance E mua E exh E radiation + E appliance + E water inlet E water drain = 0 Where: E mua is the energy in the makeup air stream E exh is the energy in the exhaust air streams E appliance is the energy input to the dishwashing machine E water inlet is the energy in the makeup hot water to the dishwashing machine E water drain is the energy in the water overflow from the dishwashing machine down the drain The convective heat and moisture loads as measured in the exhaust airstream were calculated by: Convective Loads q space-sensible load = 1.08 Q exh (T db-exh - T db-mua ) q space-latent load = 4840 Q exh (W exh - W mua ) Moisture Load m moisture load = Where: q space-sensible load is the convective sensible heat load to the space in Btu/h q space-latent load is the convective latent heat load to the space in Btu/h Q exh is the volumetric flow rate of the exhaust air stream in cfm T db-mua the dry bulb temperature of the makeup air stream in F T db-exh is the dry bulb temperature of the exhaust air stream in F W mua is the humidity ratio of the makeup air stream in pound of water per pound of dry air W exh is the humidity ratio of the exhaust air stream in pound of water per pound of dry air Q exh is the specific volume of the exhaust air in cubic feet per pound of dry air m moisture load is the mass flow rate of water vapor into the space in pounds of water per hour Page 9 of 17
10 The total heat load (convective and radiant) to the space measured from an un-hooded dishwashing machine is the appliance s measured energy rate (plug load) plus the energy in the supplied water to the unit minus the energy in the drain water. The convective load was calculated directly from the temperature and humidity rise of makeup air to exhaust air conditions and the exhaust flow rate. The convective load was split into sensible and latent components. Heat load tests were conducted during washing conditions. The dishwashing machine was stabilized by running five consecutive empty racks. The washing heat load test consisted of washing racks loaded with 3 full-size sheet pans sequentially. The dishwashing machine door was opened for 40 seconds after the 6 minute 20 second cycle time. The rack of sheet pans was replaced with a room temperature rack of sheet pans as soon as the cycle ended. The total test time for the Hobart PW10eR was 7 minutes. The dishwashing machine was recovered to 150 F before the beginning of each test cycle. The convective heat load measurements were separated into sensible and latent energy. The results of the tests are shown in the Tables below: Heat Gain Test Results Total Convective Heat load to Space (Btu/h) 20,893 ± 1,153 Convective Sensible Load to Space (Btu/h) 7,943 ± 668 Latent Load to Space (Btu/h) 12,950 ± 721 Moisture Load to Space (lb/h) 11.5 ± 0.6 Washing Energy Rate (kw) Heat Gain Operating Parameters Total Number of Cycles 8 Total Test Time (min) 56.2 Total Number of Pans Washed 24 Wash Time per Cycle (sec) 240 Rinse Time per Cycle (sec) 20 Condensate Removal Time (sec) 120 Unload/Load Time - door open (sec) 40 Cycle Time (sec) 420 Number of Full-Size Sheet Pans per Rack per Cycle 3 Weight of Sheet Pans per Rack per Cycle (lb) 9.9 Page 10 of 17
11 Heat Gain Tests Run #1 Run #2 Run #3 Test Time (min) Exhaust Airflow Rate (CFM) 1,718 1,710 1,707 Average Makeup Air Temperature ( F) Average Exhaust Air Temperature ( F) Average Makeup Air Humidity Ratio (lb water/lb dry air) Average Exhaust Air Humidity Ratio (lb water/lb dry air) Specific Volume (ft³/lb) Convective Sensible Load to Space (Btu/h) 7,635 8,057 8,137 Latent Load to Space (Btu/h) 12,871 12,707 13,272 Moisture Load to Space (lb/h) Page 11 of 17
12 Additions, Deviations, & Exclusions Additions: None Deviations: - ASTM F was performed simultaneously with F Test Method for Heat Gain to Space Performance of Commercial Kitchen Ventilation/Appliance Systems. - The door was opened and the rack of pans was removed after the cycle ended as per F and the dishwasher was allowed to recover with the door open, instead of leaving the door closed with the rack of pans inside during recovery as per F Exclusions: None Page 12 of 17
13 Manufacturer Specifications Sheet Page 13 of 17
14 Manufacturer Specifications Sheet (Continued) Page 14 of 17
15 Manufacturer Specifications Sheet (Continued) Page 15 of 17
16 Manufacturer Specifications Sheet (Continued) Page 16 of 17
17 Page 17 of 17
Food Service Technology Center
Food Service Technology Center CMA-180-VL-FL Electric Door-Type Heat Recovery Dishwashing Machine Test Report Application of ASTM Standard Test Method F1696-15 and F2474-09 May 2016 Prepared by: Edward
More informationFood Service Technology Center
Food Service Technology Center Eloma Genius T6-11 Gas Combination Oven Test Report FSTC Report # 501311112-R0 Application of ASTM Standard Test Method F2861-10 August 2012 Prepared by: Michael Karsz Denis
More informationPlateScrape Plate Pre-Scrapper Test Report
PlateScrape Plate Pre-Scrapper Test Report Application of ASTM Standard Test Method F2324-03 September 2016 Prepared by: Denis Livchak Fisher-Nickel, Inc. Contributors: Andre Hookfin Fisher-Nickel, Inc.
More informationFood Service Technology Center
Food Service Technology Center IR Energy Habanero HAB-M50 Gas Patio Heater Test Report Application of ASTM Standard Test Method FF2644-07 September 2014 Prepared by: Elan Frantz Trey Young Fisher-Nickel,
More informationFood Service Technology Center
Food Service Technology Center CMA-180 / CMA-180-VL Dishwashing Machine Expanded Test Report FSTC Application of ASTM Standard Test Methods F1696-07 and F2474-09 January 2013 Prepared by: Denis Livchak
More informationFood Service Technology Center
Food Service Technology Center Ovention M1718 Oven FSTC Report # 501311203-R0 Application of ASTM Standard Test Method F2238-09 December 2013 Prepared by: Kong Sham Fisher-Nickel, Inc.. Prepared for: Pacific
More informationFood Service Technology Center
Food Service Technology Center Rational SCC WE 202G Gas Combination Oven Test Report FSTC Report # 501311101-R0 Application of ASTM Standard Test Method F2861-10 March 2012 Prepared by: Michael Karsz David
More informationF Prepared by: Kong Sham. Prepared for: PO Box Technology Center
Food Service Technology Center Merrychef eikon e2 Appliance Test Report FSTC Report # 501311081 Application of ASTM Standard Test Method F2238-09 December 2011 Prepared by: Kong Sham David Zabrowski Fisher-Nickel,
More informationSouthern California Gas Company Customer Programs Department
Appliance Test Report SCGAT140220A Revision 0 Issued Date: March 2014 Duke 613Q-G1V Gas Convection Oven Performance Test Per ASTM F1496-13 Southern California Gas Company Customer Programs Department Food
More informationSunglo Heater Model A270 Patio Heater Performance Test
Sunglo Heater Model A270 Patio Heater Performance Test FSTC Report # 5011.07.01 January 2007 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. 2007 by Fisher-Nickel, inc. All rights reserved.
More informationTechnical Report - AM15VL Series Ventless Dishmachines
Warewash Engineering Troy, OH 45374-0001 Technical Report - AM15VL Series Ventless Dishmachines In this document: 1. Machine Operation 2. ICC Code Opinions 3. Customer Testing 4. Operational Test Report
More informationHot Food Holding Cabinets Test for FWE HLC
Design & Engineering Services Hot Food Holding Cabinets Test for Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison January 4, 2011 Acknowledgements
More informationMarket Forge, STP-6E Electric Steamer Performance Test
Market Forge, STP-6E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.05 Food Service Technology Center Final Report, December 2001 Prepared by:
More informationMetcraft Power Soak Performance Test
Metcraft Power Soak Performance Test FSTC Report 5011.02.11 Food Service Technology Center Final Report, May 2002 Prepared by: Charles Bohlig Victor Kong Fisher-Nickel, inc. 2002 by Fisher-Nickel, inc.
More informationSunpak Heater Model S25 Patio Heater Performance Test
Sunpak Heater Model S25 Patio Heater Performance Test FSTC Report # 5011.06.20 December 2006 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. 2006 by Fisher-Nickel, inc. All rights reserved.
More informationCONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E
Design & Engineering Services CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E Report ` Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison
More informationVanguard Powermax 200 Gas-Fired Booster Heater Performance Tests
Vanguard Powermax 200 Gas-Fired Booster Heater Performance Tests Application of ASTM Standard Test Method F 2022-01 FSTC Report 5011.02.10 November 2002 Prepared by: David Cowen David Zabrowski Fisher-Nickel,
More informationMiddleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test
Middleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test Application of ASTM Standard Test Method F 1817-97 FSTC Report 5011.98.63 Food Service Technology Center Manager: Don Fisher Final
More informationPrecision Temp PT-56 Gas-Fired Booster Heater Performance Tests
Precision Temp PT-56 Gas-Fired Booster Heater Performance Tests Application of ASTM Standard Test Method F 2022-00 FSTC Report 5011.03.28 October 2003 Prepared by: David Cowen David Zabrowski Fisher-Nickel,
More informationInnovative Technologies [and Design Concepts] in Commercial Foodservice
Innovative Technologies [and Design Concepts] in Commercial Foodservice Don Fisher, P. Eng. Fisher Consultants PG&E Food Service Technology Center 925-866-5770 dfisher@fishnick.com Food Service Technology
More informationAM SELECT WAREWASHER. The ENERGY STAR rated door-type AM Select warewasher is the only warewasher you need.
AM SELECT WAREWASHER The ENERGY STAR rated door-type AM Select warewasher is the only warewasher you need. 2 AM SELECT WAREWASHER The ENERGY STAR rated AM Select warewashers are like having two machines
More informationDemand-Controlled Ventilation for Commercial Kitchen Ventilation
Demand-Controlled Ventilation for Commercial Kitchen Ventilation Welcome. Today s webinar is being recorded and will be posted at: www.e3tnw.org www.conduitnw.org You may submit questions at any time during
More informationAccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance Report
AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance Report FSTC Report 5011.01.90 Food Service Technology Center Manager Final Report, December 2001 Prepared
More informationRefrigerated Prep Table Performance Testing
Refrigerated Prep Table Performance Testing FSTC Report # 5011.03.16 September 2003 Prepared by: David Zabrowski David Cowen Fisher-Nickel, Inc. Contributor: Scott Miner Fisher-Nickel, Inc. 2003 by Fisher-Nickel,
More informationAccuTemp STEAM n HOLD, Model 208-D6-3.0 Electric Steamer Performance Test
AccuTemp STEAM n HOLD, Model 208-D6-3.0 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-93 FSTC Report 5011.98.58 Food Service Technology Center Manager: Don Fisher Final
More informationEnergy & Water Savings in Commercial Food Service
Energy & Water Savings in Commercial Food Service Don Fisher Manager Food Service Technology Center 925-866-5770 dfisher@fishnick.com The Food Service Technology Center (FSTC) program is funded by California
More informationEnergy Efficiency Business Rebates Natural Gas Catalog
Energy Efficiency Business Rebates Natural Gas Catalog Solution Product Code Storage Water Heater G-A1 Storage Water Heater Natural Gas Products Product Description Units $/Unit Page # $2.00 3 Space Heating
More informationMontague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test
Montague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test Application of ASTM Standard Test Method F 1496-93 FSTC Report 5011.99.79 Food Service Technology Center Final Report, December
More informationCleveland, Model OEB-6.20 Electric Combination Oven Performance Test
Cleveland, Model OEB-6.20 Electric Combination Oven Performance Test Application of ASTM Standard Test Method F 1639-05 FSTC Report # 5011.07.11 September 2007 Prepared by: Greg Sorensen Fisher-Nickel,
More informationDemand Control Ventilation What, When and Where?
Demand Control Ventilation What, When and Where? Presented by: Todd Bell Sr. Energy Analyst Fisher-Nickel Inc. Rich Swierczyna Sr. Engineer Fisher-Nickel Inc. The Food Service Technology Center (FSTC)
More informationSchwank, Model 2312 Patio Heater Performance Test
Schwank, Model 2312 Patio Heater Performance Test FSTC Report # 5011.07.15 June 2007 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. Prepared for: Pacific Gas & Electric Company Customer
More informationFood Service Technology Center Promoting Energy Efficiency in Food Service
Account Information & Energy Potential Date Month/Day/Year 6-Oct-10 Account Number(s) Account Id # Customer Information Business Name Rubios Contact Name Tabitha Smith Title Manager Street Address on UCSD
More informationDesign Guide Improving Commercial Kitchen Ventilation System Performance
Design Guide Improving Commercial Kitchen Ventilation System Performance This design guide provides information about achieving and maintaining optimum performance and energy efficiency in commercial kitchen
More informationFT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374 Item # Quantity WITH BLOWER DRYER FLIGHT-TYPE DISHER C.S.I. Section 11400 STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital
More informationPerformance Rating of Computer and Data Processing Room Air Conditioners
ANSI/AHRI Standard 1360 (I-P) with Addendum 1 2013 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners Approved by ANSI on November 8, 2013 WITH ADDENDUM 1, PERFORMANCE
More informationTurboChef Technologies, Inc. Model D Oven
TurboChef Technologies, Inc. Model D Oven Product Evaluation FSTC Report 5011.99.70 Food Service Technology Center Manager: Don Fisher Final Report, May 1999 Prepared by: Greg Sorensen Richard Young Prepared
More informationSession: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island
Session: HVAC 101 HVAC 101 Steve Sain Sain Engineering Associates, Inc. August 9, 2016 Rhode Island Convention Center Providence, Rhode Island Why? 2 Acknowledgements 3 Disclaimer I m gonna shoot down
More informationFT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT
Project AIA # SIS # Item # Quantity C.S.I. Section 114000 COMMERCIAL DISHERS FT1000S ENERGY RECOVERY STEAM LA Research Report M660004 Complies with EPA Reduction of Lead in Drinking Water Act 2014 Meets
More information2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS
B 2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS COMMUNITY DEVELOPMENT DEPARTMENT 345 N. EL DORADO STREET STOCKTON, CA 95202 (209) 937-8561 www.stocktongov.com/cdd/building BUSINESS
More informationANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications
ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications Approved by ANSI on 19 November 2014 IMPORTANT SAFETY DISCLAIMER AHRI does not
More informationSustainable Hot Water: Better Design, Delivery, and Use
Sustainable Hot Water: Better Design, Delivery, and Use March 24, 2009 Don Fisher Amin Delagah Fisher-Nickel, inc. PG&E Food Service Technology Center The Food Service Technology Center (FSTC) program
More informationME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3
ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes
More informationFT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER
Project AIA # SIS # Item # Quantity C.S.I. Section 114000 COMMERCIAL DISHERS STEAM WITH BLOWER DRYER LA Research Report M660004 Complies with EPA Reduction of Lead in Drinking Water Act 2014 Meets requirements
More informationFT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374 Item # Quantity WITH BLOWER DRYER FLIGHT-TYPE DISHER C.S.I. Section 11400 STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital
More informationA/C Cooling Load calculation and measurement
Testo Inc. 40 White Lake Rd. Sparta NJ 07871 (800) 227-0729 A/C Cooling Load calculation and measurement When we talk about sizing an air conditioning appliance (tons of cooling, BTU/h or KW), we are specifying
More informationVENTLESS DOOR-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 VENTLESS STANDARD FEATURES Internal condensing system minimizes water vapor Does not require a vent hood Energy recovery Sense-A-Temp 70 F rise electric booster heater.74
More informationPT9150 (Extended Range)
(Extended Range) Cable Actuated Sensor Extended Ranges Incremental Encoder Linear Position to 1700 inches (4300 cm) Stroke Range Options: 0-600 to 0-1700 inches VLS Option to Prevent Free-Release Damage
More informationME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY
ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes
More informationMultiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance
DRAFT INTERNATIONAL STANDARD ISO/DIS 15042 ISO/TC 86/SC 6 Voting begins on: 2005-07-11 Secretariat: ANSI Voting terminates on: 2005-12-12 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ
More informationFINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.
More information
Performance Rating of Active Chilled Beams
AHRI Standard 1241 (SI) 2016 Standard for Performance Rating of Active Chilled Beams IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of
More informationA Cost Effective Multi-Spectral Scanner for Natural Gas Detection
A Cost Effective Multi-Spectral Scanner for Natural Gas Detection Semi-Annual Progress Report No. 1 Reporting Period Start Date: October 1, 2003 Reporting Period End Date: March 31, 2004 Principal Authors:
More informationPharmaceutical Facility Design
PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the
More informationHIGH-EFFICIENCY EQUIPMENT TECHNICAL SHEET
GENERAL INFORMATION SMECO's Business Solutions program is designed to help commercial and industrial customers maximize energy efficiency and manage energy costs. With cost-saving financial incentives
More informationAuthority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013
City of Vancouver Planning - By-law Administration Bulletins Planning and Development Services, 453 W. 12th Ave Vancouver, BC V5Y 1V4 F 604.873.7000 fax 604.873.7060 planning@vancouver.ca NEIGHBOURHOOD
More informationNew Era in Energy Efficiency!
Presentation by: David Zabrowski Director of Engineering Energy & Water Efficiency in Commercial Kitchens June 30, 2009 June 30, 2009 The Food Service Technology Center (FSTC) program is funded by California
More informationAHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers
AHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers - ERRATA SHEET FOR AHRI STANDARD 1250 (I-P)-2009, PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS December
More informationLXeR and LXePR HOT AND COLD
Item # Quantity C.S.I. Section 11400 LXeR and LXePR HOT AND COLD STANDARD FEATURES Racks per hour Light Normal Heavy LXeR 30 24 13 LXePR 38 29 14.62 gallons of water per rack LXeR 1.14 gallons of water
More informationKitchenology: Tales of Transformation and Efficient and Effective Operations
Kitchenology: Tales of Transformation and Efficient and Effective Operations Kitchenologist: Mark Finck Download Today s Handouts: www.fishnick.com/handouts/03062017 Back-ground Started in QSR as Crew
More informationSummary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000
SAE Alternate Refrigerant Cooperative Research Program Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 To: Alternate Refrigerant Task Force Members From: Ward Atkinson
More informationHEATING AND COOLING REBATES
Thank you for choosing to increase your customer's home energy efficiency with heating and cooling rebates. Follow the steps below to ensure eligibility to receive a rebate from the ComEd Energy Efficiency
More informationHEATING AND COOLING REBATES
Thank you for choosing to increase your customer's home energy efficiency with heating and cooling rebates. Follow the steps below to ensure eligibility to receive a rebate from the ComEd Energy Efficiency
More informationFT SERIES FT1000e ELECTRIC
Project AIA # SIS # Item # Quantity C.S.I. Section 114000 COMMERCIAL DISHERS FT1000e Advansys model shown UL, NSF & ENERGY STAR APPROVALS PING SPECIFIER STATEMENT The specified machine shall be a Hobart
More informationUser's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290
User's Guide Pinless Moisture/Humidity Meter + IR Model MO290 Introduction Congratulations on your purchase of the Extech MO290 Pinless Moisture Meter with Patented Built-in IR Thermometer. Monitor moisture
More informationFT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER
Project AIA # SIS # Item # Quantity C.S.I. Section 114000 COMMERCIAL DISHERS FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Advansys model shown UL, NSF & ENERGY STAR APPROVALS PING Complies with EPA
More informationFT1000S BASE FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FLIGHT-TYPE DISHER STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital controls with machine diagnostics Low temperature
More informationFT1000 FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FLIGHT-TYPE DISHER STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital controls with machine diagnostics Low temperature
More informationFSTC Equipment Test Report
FSTC Equipment Test Report Purpose of Testing The Stirling Ultracold SU780XLE freezer was tested to characterize its energy usage and temperature stability during periods of both idle and door openings
More informationRedesign of Bennett Hall HVAC System
MEE 488 April 18, 2006 Redesign of Bennett Hall HVAC System Greg Andreasen Michael Chicoine Florent Hohxa Jason Jacobe Mechanical Engineering, University of Maine, Orono ME 04473, USA ABSTRACT Our task
More informationPacific Gas and Electric Company
Pacific Gas and Electric Company PY2009 Emerging Technologies Program Application Assessment Report #0911 Laboratory Evaluation of the Seeley Climate Wizard Indirect Evaporative Cooler Issued: September
More informationModels. Options. Standard Features. LoH 2 O
LoH O Models LoH O Standard Features Uses 8 gallons (9. liters) of water per hour with sanitizing hot water rinse All tanks and hoods constructed from durable stainless steel with a No. finish and heliarced
More informationFT900BD FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FT900BD FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system Water usage 120 gph @ 20 psi Microprocessor controls Low temperature alert Blower dryer with 2 H.P.
More informationPG&E s Applied Technology Services Hot Water Technology Performance Laboratory
PG&E s Applied Technology Services Hot Water Technology Performance Laboratory Edwin Huestis, P.E. Senior Mechanical Engineer PG&E Applied Technology Services ACEEE Hot Water Forum February 23, 2016 Presentation
More informationA FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS
EML-624 A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS FOR HOMELAND SECURITY PURPOSES Paul Bailey Environmental Measurements Laboratory U.S. Department of Homeland Security 201 Varick Street,
More informationFT900D DUAL RINSE FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system with dual rinse Water usage 90 gph @ 20 psi Microprocessor controls Low temperature alert
More informationPortable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217
Portable Air Conditioner with Heat Pump Technology Operating Instructions 3092402 Model No.: HCB-P13HP-D Reference No.: BPD13HP V140217 Thank you for choosing a Soleus Air Portable Air Conditioner with
More informationTHEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11
Table of Contents INTRODUCTION 1 THEORY OR OPERATION 2 DESCRIPTION 5 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 SPECIFICATIONS 10 OPTIONS
More informationModular Active. Chilled. Beams
Modular Active Chilled Beams How Twa MAC Beams Work Primary air (100% outside air) is dehumidified to between 50-57 F dew point and is used to: control the latent requirements of the space, provide fresh
More informationFor an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.
1 PSYCHROMETICS Psychrometry is the study of the characteristics of moist air. We will see soon that evaporation of moisture from the skin can have a significant impact on thermal comfort. The rate of
More informationD-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)
More informationUser's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295
User's Guide Pinless Moisture/Humidity Meter with Memory + IR Thermometer Model MO295 Introduction Congratulations on your purchase of the Extech MO295 Pinless Moisture Meter with Patented Built-in IR
More informationEnergy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE
This article was published in ASHRAE Journal, March 20145 Copyright 2015 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission
More informationCR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions
OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight
More information2010 Home Energy-Efficiency Rebate Program
2010 Home Energy-Efficiency Rebate Program Cash rebates for existing single-family detached homes, attached homes (up to four-plex), condominiums and mobile homes. HOW TO APPLY 1. Read the Terms and Conditions
More informationFT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system with dual rinse Water usage 72 gph @ 20 psi Microprocessor controls Low temperature
More informationUsers Manual. LAURUS Systems, Inc. - Ph: Fax:
Users Manual LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com Introduction The rad-d is a security and inspection system that detects emissions from radioactive material.
More information12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International
12,000 BTU Portable Air Conditioner Operating PE3-12R-03 Instructions 3092402 Model No. PE3-12R-03 2010 Soleus Air International Thank you for choosing a Soleus Air PE3-12R-03 Portable Air Conditioner.
More informationSIGMADEK, LTD. FIRE TEST REPORT
SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION
More informationFT900 FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FT900 FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system Water usage 120 gph @ 20 psi Microprocessor controls Low temperature alert Single point vent connection
More informationMultifamily Energy Efficiency Rebates Application Package
Application Package Cash rebates are available for the installation of qualified energy efficiency products in apartment dwelling units and in the common areas of apartment complexes, condominium complexes,
More informationModel R060 Installation - Operation Manual
Residential Heat Pump Water Heaters Model R060 Installation - Operation Manual Important Note Read this entire manual before beginning installation Manufactured By: 6670-A Corners Industrial Court Norcross,
More information14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International
14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions 3092402 Model No. LX-140 2012 Soleus Air International Thank you for choosing a Soleus Air LX-140 Portable
More informationTHE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR
Source Application Manual SAM Chapter 620-20 Section 03 THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION Problems involving changes in temperature, humidity,
More informationTEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #4 System Drop-in Test of Refrigerant R-32 in Split System Heat
More informationGroen Vortex, Model VRC-6E Electric Steamer Performance Test
Groen Vortex, Model VRC-6E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report # 5011.03.23 May 2003 Prepared by: Victor Kong David Zabrowski Fisher-Nickel,
More informationCalculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors
Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors ET Project Number: Product Manager: Sachin Andhare Pacific Gas and Electric Company` Prepared By: Danielle Geers
More informationHEATING AND COOLING REBATES
Thank you for choosing to increase your customer's home energy efficiency with heating and cooling rebates. Follow the steps below to ensure eligibility to receive a rebate from the ComEd Energy Efficiency
More informationNew Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review
New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review FSEC-PF-454-11 May 2011 Author Carlos Colon Copyright 2011 Florida Solar Energy Center/University
More informationJH Series Installation
JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by
More informationPT9600. Cable Actuated Encoder Reel. General. Environmental
Cable Actuated Encoder Reel Converts ANY Rotary Encoder to a Linear Position Sensor Linear Stroke Range up to 550 inches (14 m) Mates Virtually ANY Customer Supplied Encoder Factory Supplied Encoder Available
More information