Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning
|
|
- Antonia Marsh
- 5 years ago
- Views:
Transcription
1 Quick guide
2 Foot No instrument selected Key Press briefly Preset ing A Raise chair Chair to working 1 B Incline backrest Chair to spitting C Lower chair Chair to entry and exit D Decline backrest Chair to working 2 e Switch operating light on/off F Open door lock g Activate preset Return chair to ing previous H I Instrument selected Key Key Micro motor Turbine Scaler Curing Syringe Camera press type light E Brief Select rotation scale F Brief Toggle water / Toggle water / air / both / off air / both / off G Long Chip blow Chip blow Freeze continuous continuous image H Long Run Run Run I Long Run Run Run : s Idle state The power is switched on, but the system is not currently doing anything. Scaler power The ACT text illustrates when scaler is in use. Micro motor speed The micro motor is in use. Curing light The curing light is selected.
3 Instrument bridge and suction head user interface Instrument bridge user interface Key Symbol Press briefly Function Press and hold Pre-set ing Timer/Menu Doorbell Start timer, duration 30 s or other preset time Open door, preset duration Activate menu Open door, continuous Bowl rinse Rinse bowl for preset duration D A C B Cup fill Rotation Fill cup for preset duration Change rotation scale Fill cup continuously Reverse rotation Instrument water Toggle instrument water on/off All instrument flushing Instrument air Toggle instrument air on/off Suction head user interface Operation light External device Switch on or off operation light Depends on configuration Chair up Raise chair Raise chair Chair to working 1 Backrest up Incline backrest Incline backrest Chair to spitting Chair down Lower chair Lower chair Chair to entry and exit D A B Backrest down Decline backrest Decline backrest Chair to working 2 C Preset Activate preset ing Saving s Return chair to previous
4 Saving your own settings Saving the s for chair Position the chair to the desired. Press and hold the -button to start saving. Select the desired memory slot (,,, ) with the corresponding button from the instrument panel. Selecting the memory slot Pre-set button 3 Utilisation 3.1 Allumer et couper le dispositif! Using pre-set s Press the -button to recall the pre-set s. Select the desired memory slot (,,, ) with the corresponding button from the instrument panel to recall the. -button returns the chair to previous. The factory settings, which can be altered: Chair to working 1 (the backrest up, working while sitting) Chair to spitting Chair to entry and exit Chair to working 2 (the backrest up, working while standing) Select the user Press and hold the -key on the instrument bridge. This will bring up the menu display. The menu can be operated using the, and -buttons on the instrument bridge. From the user selection you can choose the user and utilise saved settings. Avertissement! L''intérieur du boîtier de jonction est soumis à des niveaux dang d'air et d'eau sous pression. Seul un technicien de maintenance habilité à ouvrir le boîtier de jonction. Remarque! Lorsque l'appareil est allumé, la tablette d'instruments, le module d'a et la boîte de jonction sont soumis à de l'eau et de l'air sous pression Commutateur de mise sous tension Commutateur de mise sous tension Le dispositif est mis en marche ou arrêté grâce au commutateur de m Celui-ci contrôle toute l'électricité du dispositif. Si le commutateur est dispositif peut se faire sans danger. Lorsque le système n'est pas so l'eau à l'intérieur du dispositif sont dépressurisés. 3.2 Sélection de l'utilisateur Selecting the user Appuyer sur la touche de la tablette d'instruments et la mainten fiche le menu présenté à la figure suivante. MENU. TIMER USER CLOCK CART MOVE FLUSH (i ) Affichage du menu Cleaning and disinfecting Disinfecting the suction system insert the suction hoses to the connectors in the bottom of the cuspidor remove the filling hole lid pour the disinfectant solution into the filling hole wait until the solution has gone through the suction hoses. replace the suction hoses. All instrument flushing To start the all instrument flushing operation, press and hold the -button until the flush-menu appears. Insert instruments to the instrument flushing -holder. From the flush-menu, select the suitable time for flushing. The options are: 30 seconds, 3 minutes and 10 minutes. The min +1 and min -1 menu items adjust the 10 minute time accordingly. The water can be taken from the clean water bottle or from mains water. It is also possible to use a disinfection solution in the clean water bottle. After flushing with the desinfectant flush with fresh water before treatment. G
5 Quick start Switch the power on The main power switch is located in the connection box. Using pre-set s Press the -button to recall the pre-set s. Select the desired memory slot (,,, ) with the corresponding button from the instrument panel to recall the. Chair to working 1 (the backrest up, working while sitting) Chair to spitting Chair to entry and exit Chair to working 2 (the backrest up, working while standing) Switching power on Power switch Selecting the memory slot Pre-set button Position the chair The chair can be operated with joystick(s), remote foot, instrument bridge buttons, and suction head buttons. Positioning the chair Position the headrest The distance between the headrest and backrest can be adjusted simply by sliding the headrest in or out. Positioning the headrest The movements of the headrest are double articulated. Use the lever to lock the mechanism. Turning and detaching armrests Lift the armrest slightly. Turn it 900. Detach the armrest in this. Turning and detaching armrests 13:
6 Safety precautions Electricity and pressurised water and air Do not open the door of the cuspidor during the patient treatment to prevent the risk of an electric shock. The maximum connection voltage to the relays for the external devices is 24V. There are harmful voltage levels, pressurized air, and water inside the connection box. The connection box may be opened only by an authorized service person. To avoid the risk of an electric shock, this equipment must only be connected to supply mains with the protective earth. Connecting devices not compliant with IEC or IEC may cause an electric shock hazard. Do not touch non-medical devices simultaneously with the patient. There is a risk of electric shock. Only qualified service personnel is allowed to replace the remote foot s rechargeable batteries. Treating patients Check that there is water and not disinfecting solution in the clean water bottle before the treatment. Flush the water lines with fresh water before treating patients after using disinfection solutions. Follow the disinfectant liquid manufacturer s instructions. To avoid the risk of fire, this equipment must not be used with flammable anaesthetics. Using the chair Check that nothing is obstructing the movements of the chair to prevent damage to the system. Beware of damaging the instrument bridge arms when lifting the backrest of the chair. Do not sit on the backrest or footrest. They may bend under your weight. Check the tightness of the locking mechanism after adjusting the of the headrest. Instruments Check that the scaler gets water for cooling. The scaler may get damaged if it is not cooled. Avoid looking straight at the curing light because it may damage your eyes. Check the locking of the instrument drill bit mechanism after replacing the drill bit. The operating light Do not look straight into the operating light. Staring the light beam may cause damage to eyes. Maintenance and cleaning The display is not water proof. Beware wetting the display when cleaning the system. Use only bottles provided by Fimet Oy. Otherwise there is a possibility that the bottle breaks. Be cautious when using flammable disinfection/cleaning agents because of the risk of fire. Do not smoke or handle fire when handling flammable agents. Using instruments which are not disinfected or sterilised may cause infection hazard to the patient or operator. Follow the instrument manufacturer s instructions on disinfection and sterilisation. More information More information about using the Fimet Neo system is in the user guide. The user quide can be obtained from 3/2014/ek Fimet Oy Teollisuustie 6 FI Monninkylä Finland Tel: Fax: fimet@fimet.fi
FOR YOU AND YOUR CUSTOMER
FOR YOU AND YOUR CUSTOMER ELEGANT AND COMPACT DESIGN The ergonomic and elegant design of the Fimet Neo dental treatment unit makes your practise more functional and convenient than ever before. The Neo
More informationFimet F1 User Guide Version
Fimet F1 User Guide Version 1.1 1.6.2016 Table of contents 1 Introduction... 5 1.1 Manufacturer... 5 1.2 Models Covered by this User Guide... 5 1.3 Directives and Standards... 5 1.3.1 Quality Standards...
More informationDental Unit User's Guide
Dental Unit User's Guide MDD 93/42/EEC May 1999 8200590 Quint-7000 User's Guide We reserve the right to make changes. Manufactured by: FINNDENT OY Teollisuustie 5 FIN-07230 MONNINKYLÄ Tel. +358 19 5221500
More informationDynamics Precision Speed
English FD-8000 Dental Units Vol. 07/2014 Dynamics Precision Speed 8000B floor units are known for reliability and style. The possibilities are endless, with several options for suction, cuspidor, amalgam
More informationIlluminated Stopper Station Push Button
Illuminated Stopper Station Push Button Model SS2xx6 Rely on STI Dimensions 4.880 in [123.95 mm] 3.218 in [81.74 mm] 1.625 in [41.28 mm].875 in [22.23 mm] Switch Rating 2 momentary independent Form C contacts,
More informationFlexibility and individual design turn your dental unit into an active partner. Quality is not a consideration quality is the solution
X X Flexibility and individual design turn your dental unit into an active partner Quality is not a consideration quality is the solution 2 3 Complete control - with the foot Leave the possibilities open
More informationStopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9
Installation and Service Instructions Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9 ADA Compliant NOTE For LTUL Models, Form C contacts on timer, Rated 30 VDC 3A, the enclosed timer
More informationStopper Station Series SS-2008 Push Button Pneumatic Timer Button
Stopper Station Series SS-2008 Push Button Pneumatic Timer Button ADA for operation Pneumatic Timer Models SS-2008 Red SS-2108 Green SS-2208 Yellow SS-2308 White SS-2408 Blue ALL MODELS COME WITH A COLOR
More informationOperation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation
Document n 1408-1 ~ 11/02/2010 Control Box FR EN NL DE IT Operation manual intended for professionals and end users To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549
More informationInstallation Instructions
Installation Instructions 42" Island Vent Hood ZV1050 monogram.com 1 Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for local inspector s
More informationUnlimited Mobility. The Mobile Dental Units From. B-Productions
Unlimited Mobility The Mobile Dental Units From B-Productions Mobile Units from B-Productions: Unlimited Mobility in elegant stainless steel DENTA-PORT 303 Specifications» Portable: Treat your patients
More informationMICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL
MICROWVE OVEN UNDER-THE-CINET INSTLLTION INSTRUCTIONS This product is not intended for use above any heat source, such as a range or cooktop. See Installation Requirements section for further notes. These
More informationFONA DURION Dental unit operation instruction
Dental unit operation instruction Index 1. General information... 5 General information on the Operation Instructions... 5 Scope of these Operation Instructions... 5 Other valid documents... 5 Warranty
More informationPlanmeca Sovereign Classic
KI Page 1(25) Planmeca Sovereign Classic Planmeca Sovereign Classic dental unit is the perfect outcome of clever design details that facilitate your work throughout the day. From patient treatment to easy
More informationChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual
ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual asaanalytics.com ChemScan mini Low Ammonia Analyzer O&M Manual - Rev 223K TABLE OF CONTENTS ANALYZER DESCRIPTION
More informationOPERATING INSTRUCTIONS
DENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instructions for VOYAGER II. The instructions contained in this booklet should be thoroughly read and understood before
More informationINSTALLATION INSTRUCTION In-Ground Color Changing
SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationOPERATING INSTRUCTIONS
DENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instructions for VOYAGER-II L. The instructions contained in this booklet should be thoroughly read and understood
More informationINSTALLATION INSTRUCTION In-Ground
SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationOPERATING INSTRUCTIONS
H DENTAL UNIT BOOK NO. 1E03D2C0 (3E) Printed in JAPAN. 2014-07 OPERATING INSTRUCTIONS Thank you for purchasing TAKARA BELMONT product. Please read through this instruction manual carefully before using
More informationDEKO 25 washer-disinfector
DEKO 25 washer-disinfector DEKO 25 The DEKO 25 has been designed to bring reliability, outstanding cleaning and disinfection performance and quality into one compact and economic washer-disinfector. It
More informationShort instructions for use ESTETICA E30
Short instructions for use ESTETICA E30 Distributed by: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Tel. +49 7351 56-0 Fax +49 7351 56-1488 Manufacturer: Kaltenbach & Voigt GmbH Bismarckring 39 D-88400
More informationXO FLEX User Manual 2
XO FLEX USER MANUAL XO FLEX User Manual 2 XO FLEX User Manual Table of contents CONTENTS 1 EXTRAORDINARY DENTISTRY... 7 2 Symbols... 8 3 Operation... 9 3.1 General... 9 3.2 Arm systems... 11 3.3 Hand instrument
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 70044220 Issued to: Cascade Technologies Limited Glendevon House Castle Business Park Stirling FK9 4TZ UK Attention: Mr. Marcus Douglas The products listed
More informationPEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL
PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL Table of Contents PEDESTAL SAFETY... 1 INSTALLATION REQUIREMENTS... 2 Tools and Parts... 2 Location Requirements... 2 Before
More informationCHIRANA Medical, a. s.
CHIRANA Medical, a. s. Námestie Dr. A. Schweitzera 194 916 01 Stará Turá Slovak Republic tel.: +421 (32) 775 2257 fax: +421 (32) 775 2218 e-mail: medical@chirana.eu www.chirana.eu Registered trade marks:
More informationSEL-3422 Motor Relay HMI Quick-Start Guide
SEL-3422 Motor Relay HMI Quick-Start Guide Overview The SEL-3422 Motor Relay HMI indicates the SEL-849 operation status through the ten LEDs on its front panel. Eight of these LEDs are programmable. The
More informationLumination TM Volumetric Retrofit Kit
GE Lighting Installation Guide Lumination TM Volumetric Retrofit Kit BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Luminaire wiring
More informationUnlimited Mobility The Mobile Dental Units By. BPR Swiss
Unlimited Mobility The Mobile Dental Units By Product Overview The world of mobile dental carts: The world of portable plug-and-play dental units: The world of portable dental units: The world of portable
More informationSERRES SUCTION BAG SYSTEM MANUAL
SERRES SUCTION BAG SYSTEM MANUAL INSTRUCTIONS FOR USE Please read this manual carefully before installing or using the Serres Suction Bag System. A B C 1 C6 C4 C5 C2 C1 C3 3.1 3.2 1 2 3 3.3 3.4 2.1 2.2
More informationDEKO 190 Ward washer-disinfector
DEKO 190 Ward washer-disinfector SUPERIOR PERFORMANCE, LARGE CAPACITY AND ADVANCED STATE-OF-THE-ART CONTROL DEKO 190 The DEKO 190 is designed and constructed to exceed the standard performance and design
More informationSiemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1
SIMATIC IPC277E Product Information General notes ATEX/IECEx - Additional Instructions for use in Gas Explosive Atmospheres (only valid for specific MLFBs - marked with IECEx/ATEX symbol on the nameplate
More informationShort instructions for use ESTETICA E30
Short instructions for use ESTETICA E30 Distributed by: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Phone +49 (0) 7351 56-0 Fax +49 (0) 7351 56-1488 Manufacturer: Kaltenbach & Voigt GmbH Bismarckring
More informationUNI 321. User s Guide
UNI 321 User s Guide Ver 1.1 Dec. 2018 Contents Read Before Operating... 2 General Information... 3 User Interface... 3 Display... 3 Normal Operation... 3 Normal Mode Operation... 4 Turning the Unit On...
More informationINSTRUCTION / INSTALLATION / TECHNICAL MANUAL
Suntem INSTRUCTION / INSTALLATION / TECHNICAL MANUAL ADAPTABLE MODEL: ST-D520 ST-D530 ST-D540 Thank you for purchasing the dental therapy unit produced by our company. Please read this manual carefully
More informationVisionAire V. Oxygen Concentrator Patient Manual
VisionAire V Oxygen Concentrator Patient Manual AirSep Corporation 401 Creekside Drive Buffalo, New York 14228-2085 USA Telephone: (716) 691-0202 24-Hour Fax (716) 691-4141 www.airsep.com Table of Contents
More informationLOGIC CONTROLLED DEKO 25 EASE OF USE
DEKO 25 Washer-disinfector WASHROOM SYSTEMS DEKO 25 The DEKO 25 has been designed to bring reliability, outstanding cleaning and disinfection performance and quality into one compact and economic washerdisinfector.
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
ZR Series Commercial Specification Troffers with Emergency Driver Includes: ZR14, ZR22 and ZR24 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationInstallation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.
Installation & Operation Manual AromaFlo Feel Good Inc. WARNING Risk of electric shock - This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric
More informationLS Condensate Removal Pump Installation, Operation and Service Instructions
Bell & Gossett Instruction Manual 6-71-075-115 LS Condensate Removal Pump Installation, Operation and Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. WARNING: This safety
More informationLow Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit
Low Voltage Fan Coil Thermostat ST101ZB Quick Start Guide For other language versions, please visit www.salusinc.com Notices Please read these instructions carefully before installing and using the Low
More informationZ-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée
Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée Congratulations on the purchase of your new ANTARI Z-SERIES II FOG MACHINE.
More informationIce Maker. Use and Care Instructions. with water dispenser. Durable, high-quality stainless steel finish
Use and Care Instructions Ice Maker with water dispenser Durable, high-quality stainless steel finish Unique design uses water cooler -style five gallon water jug to conveniently supply ice or cold drinking
More informationGARAGE DOOR OPENER KIT
GARAGE DOOR OPENER KIT P/N 2883417 APPLICATION All 2018 and newer Slingshot models with Garage Door Opener By Homelink Kit PN 2881814 BEFORE YOU BEGIN Read these instructions and check to be sure all parts
More informationVault Accessories Deluxe Kit
Vault Accessories Deluxe Kit Instructions #1031640 Product #222498 A. B. D. C. E. A. Hygrometer B. 12 Dehumidifier C. Large Hanging Organizer D. Cordless Automatic Vault Light E. Magnetic Barrel Rest F.
More informationNarrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC
Commercial Refrigerator And Freezer User s Manual Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC 10/2016
More informationWireless Outdoor Air Reset Adaptor PN:
Wireless Outdoor Air Reset Adaptor PN: 105767-01 Instruction Sheet APPLICATION The Wireless Outdoor Air Reset Adaptor, when connected to the Concert Boiler Control enables efficiency control functionality
More information200i User s information manual
M2i-UM-1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Cast iron condensing boiler 200i User
More informationTechnical data. Bathroom/shower room installations. Water services (WRAS approved)
Technical data The Closomat toilet MUST be installed by a competent or qualified person. Explanation of symbols Safety instructions in this manual are identified by symbols. The safety instructions are
More informationGBX GAS BOILERS USER S INFORMATION MANUAL
S-GBXUM-2 00-GBXUM GBX GAS BOILERS USER S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury
More informationIntelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone
Model: isb01 Intelligent Home Solutions Quick Start Guide Wi-Fi MOTION SENSOR Monitor your home from anywhere with your smartphone WHAT YOU LL NEED WiFi network transmitting at 2.4GHz; WPA2 security type
More informationWi-Fi DOOR/WINDOW SENSOR
Model: isb04 Intelligent Home Solutions Quick Start Guide Wi-Fi DOOR/WINDOW SENSOR Monitor your home from anywhere with your smartphone WHAT YOU LL NEED WiFi network transmitting at 2.4GHz; WPA2 security
More informationOperating Manual for Profident / Profident PLUS
Operating Manual for Profident / Profident PLUS Content: 1. Accessories... 1 2. First Steps... 2 2.1 Air Pressure... 2 2.2 Positioning of the Handpieces... 2 2.3 Pressurised Water Bottle... 3 2.3.1 Refill
More informationQUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003
QUICK START GUIDE Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003 Welcome. This guide will help you install your Lono controller. For additional information, check out our installation
More informationStopper II Heated Enclosure
Stopper II Heated Enclosure STI-1200A-HTR STI-1200A-HTR240 ADA Compliant Maintains initiating device temperature with external temperatures to -70 F (-57 C). Independently tested to -102 F (-73 C). Protects
More informationInstructions for use KaVo Primus 1058 S/TM/C/G. Always be on the safe side.
Instructions for use KaVo Primus 1058 S/TM/C/G Always be on the safe side. Sales: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Tel. +49 7351 56-0 Fax +49 7351 56-1488 Manufacturer: Kaltenbach & Voigt
More informationDEKO 260 Washer - Disinfector - Dryer
DEKO 260 Washer - Disinfector - Dryer HIGH QUALITY, EFFICIENT WASHING PERFORMANCE WITH SHORT CYCLE TIMES DEKO 260 The Deko 260 washerdisinfector-dryer is designed and manufactured to be fully compliant
More informationSkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL
SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL VERSION 1.1 22/08/2018 VISIT OUR WEBSITE FOR MORE INFORMATION. WWW.BOSSPAC.COM WASP is a registered trademark owned
More informationVisionAire. Oxygen Concentrator Patient Manual
Oxygen Concentrator Patient Manual VisionAire AirSep Corporation 401 Creekside Drive Buffalo, New York 14228-2085 USA Telephone: (716) 691-0202 24-Hour Fax (716) 691-4141 Table of Contents Important Safety
More informationKSBC1B0 W C_ENv01.indd 1 9/14/16 11:49 AM
KSBC1B0 PARTS AND FEATURES PARTS AND ACCESSORIES Ingredient cap with measuring cup Flex Edge tamper Lid Blender jar Talon blade Power cord socket and removable power cord (not shown) Cord cleat (not shown)
More informationVIVA ace Quick Operation Guide
VIVA ace Quick Operation Guide Contents 1. Installing the Holder Bar and Arm...2 2. Connecting the Motor, the Scaler, and the Syringe...3 3. Installing the Vacuum...4 4. Installing the Water Bottle...5
More informationVoyager 125 E F S. Please read these instructions before use. Lire ces instructions avant utilisation. Lea estas instrucciones antes del usarlo.
High-Performance e OOffice Laminator TM Voyager 125 E F S Please read these instructions before use. Lire ces instructions avant utilisation. Lea estas instrucciones antes del usarlo. VOYAGER LAMINATOR
More informationInstallation Instructions If you have questions, call 800-GE-CARES or visit our website at:
Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 30" Convection Built-In Ovens Models: ZET1038 ZET1058 Monogram. We bring good things to life.
More informationSystem 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules
FANs 930, 125 Product/Technical Bulletin S350 Issue Date April 8, 2014 System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s The S350A, S351A, and S352A Stage s are intended to be used
More informationVIDEO CONTROLS LIMITED
VIDEO CONTROLS LIMITED MAXCOM PRO SERIES TELEMETRY CONTROL SYSTEMS Operation Guide for use with MaxCom 3V, MaxCom 3VE, MaxCom 4V and MaxCom4VE Document Code number - CI431V2 Table of Contents Safety Instructions
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR THERMADOR BUILT-IN DISHWASHERS Models: DW244UB / DW244UW DW245UB / DW245UW DW246UB / DW246UW / DW246US DWI246UB / DWI246UW Please read this entire instruction manual before
More informationCare instructions ESTETICA E80. Always be on the safe side.
Care instructions ESTETICA E80 Always be on the safe side. Distributed by: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Tel. +49 7351 56-0 Fax +49 7351 56-1488 Manufacturer: Kaltenbach & Voigt GmbH
More informationUser s Manual for FT SERIES THE
User s Manual Document 1343D User s Manual for THE FT SERIES Wall-Mounted, Modulating Gas, Condensing, Heating Only, Boiler Model FTHW 80,000 BTU/hr 100,000 BTU/hr 120,000 BTU/hr 140,000 BTU/hr 199,000
More informationUse and Care Guide. Over the Patient Units and Swing Mount Units
Over the Patient Units and Swing Mount Units Table of Contents Page General Information 2 Operation 3-5 Dental Unit Adjustments 6-10 Cleaning, Disinfecting and Sterilization 11-12 Maintenance 13-15 Page
More informationOZONE DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL MODEL:
OZONE DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL MODEL: 0077-0010 Manufactured With Pride In The USA www.ameriwater.com 800-535-5585 AmeriWater 3345 Stop 8 Rd. Dayton, OH 45414 PN 98-0121 Rev.
More informationDyna-Form Air. Alternating Pressure Relief Overlay System
Dyna-Form Air Alternating Pressure Relief Overlay System 1 Contents Introduction 3 Cleaning 10 General Warnings 4 Control Unit 10 Unpacking / Setting Up 5 Air Filter 10 Setting Up 6 Mattress Cover 11 Connect
More informationRELIABILITY AND TECHNOLOGY, SUITABLE FOR EVERY STYLE. MIGLIONICO.NET
RELIABILITY AND TECHNOLOGY, SUITABLE FOR EVERY STYLE. MIGLIONICO.NET RELIABILITY AND TECHNOLOGY, SUITABLE FOR EVERY STYLE. Technology at the service of functionality and security. Simple and versatile
More informationInstallation & Operating Guide
5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase
More informationWasher disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items
Washer disinfectors MLC Series for transfer trolleys, sterile containers and bulky items MLC Series Washer disinfectors for transport trolleys, sterile containers and bulky items Saving time is a must!
More information(The chances are you re never going to read me) Owner s Manual.
(The chances are you re never going to read me) Owner s Manual www.simplicityvac.com . CONTENTS Getting Started Important Safety Instructions 2 Polarization Instructions 3 State of California Proposition
More informationIXIUM. DVR Smoke Alarm. User Manual
IXIUM DVR Smoke Alarm User Manual Contents Package Contents... 2 Before You Start... 2 Overview: Smoke Alarm... 3 Controls: Smoke Alarm... 3 On/Off Switch... 3 SD Card Slot (TF)... 4 USB: Syncing and Charging...
More informationMascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH
User s Manual Document 1286A User s Information for Mascot LX Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH Combination Boiler Model MLXC 125, 150 and 175 MBH FOR YOUR
More informationCAUTION CAUTION WARNING. Vulcan RT Heater With Remote Temperature Controller
Congratulations for choosing VULCAN RT electric heating system. It is loaded with 37,000 BTU s (11KW) of heat power, 475 CFM of air flow and precise temperature controls. It features individually controlled
More informationCER-1 & CER-2 Installation & Testing Instructions
CER-1 & CER-2 Installation & Testing Instructions i Read all installation instructions completely before installing this device. 1 2 3 INTRODUCTION This document details the installation procedure for
More informationTR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:
Operating manual Serial Number: Registered at Medical Products Agency, Sweden, as a MD Class 1 product, MDD 93/42EEC. TR reserves the right to make design changes and/or improvements without notice. Always
More informationWarmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R
CM CAUTION: Read all instructions carefully before installation. Save this Installation Manual for future reference. Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL ENCLOSURE TYPE 3R AUTOMATED
More informationHFG 12 and 24 Hydrogen Generators Installation Instructions
HFG 12 and 24 Hydrogen Generators Installation Instructions Model 12 Model 24 PLEASE READ THESE INSTRUCTIONS FROM BEGINNING TO END BEFORE STARTING YOUR INSTALLATION. If you are still having problems after
More informationCascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions
Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions PENNER PATIENT CARE, INC Box 523 / 101 Grant St. Aurora, NE 68818 560750 Revision A 12/11/15 1-866-PENNERS
More informationFIMET F1 DENTAL EQUIPMENT
FIMET F DENTAL EQUIPMENT FIMET R0000 Hose carrier assembly kit R00 Hose carrier R00 Hose carrier fixing pieces with screw R00 Hose carrier spring R00 Bearing R0 Hose cover RBIT Holder tube R00 Handle R0
More informationAB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document
Installation Instructions ControlNet Coax Tap (Cat. Nos. 1786-TPR, -TPS, -TPYR, -TPYS) What s in This Document Use this document as a guide when installing a ControlNet coax tap. To: See Page: verify package
More informationSuperCELL Model SC500-H-SM User s Information
SuperCELL Model SC500-H-SM User s Information Antenna Swivel Clip Alarm Power Menu LCD Display Power Select Operation Status LED Alarm Up 1 Message Down 1 Message Up 16 Messages Down 16 Messages Front
More informationRead this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER
ENGLISH ESPAÑOL Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER MODEL : LP0817WSR LP1017WSR LP1217GSR LP1417SHR LP1417GSR
More informationInstructIons for use A-dec 561 Cuspidor
Instructions for Use A-dec 561 Cuspidor Copyright 2014 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied
More informationRegister your product ONLINE today
800.355.2762 2012 Human Touch, LLC. Patents pending and intellectual property rights enforced. No medical claims are warranted or implied by the use of this product. Human Touch is a trademark of Human
More informationDH 100 P. Always Dry dehumidifier. with. Condensation Removal System
DH 100 P Always Dry dehumidifier with Condensation Removal System IMPORTANT SAFEGUARD Read all instructions before using this dehumidifier. To reduce the risk of fire, electric shock, or injury to persons
More informationKit Instructions COMMON VENT KIT (PVC AND DURAVENT)
Kit Instructions COMMON VENT KIT (PVC AND DURAVENT) CONTENTS. Introduction 2. PVC Common Vent Kit Instructions (See Page 3) 3. Polypropylene Common Vent Kit Instructions(See Page 9) SERVICING SHOULD ONLY
More informationVulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM
www.inspiredfirefx.com Vulcan Fire Module (VFM) Owner s Manual Installation and Operation Vulcan Fire Module Certified by Lab Test Certification Meets: ANSI Z21.97-2014 CSA 2.41-2014 CSA C22.2 No. 3-M1998
More informationAtomic Digital Office Clock
Atomic Digital Office Clock MONTH DATE For online video support: http://bit.ly/laxtechtalk Instructional Manual Model: 513-1419BL-WA DC:112516 Protected under U.S. Patents: 5,978,738 6,076,044 RE43903
More informationZone controller System ZC207DK INSTALLATION INSTRUCTIONS
Indication Panel Diagnostic. Power - The Green LED is ON when Power is supplied to the controller. K1 - LED is ON when the relay K1 is close. Operates the Acu. K2 - LED is ON when the relay K2 is close.
More informationInstallation Instructions
Design Guide with Installation Instructions Wine Reserve ZDWT240 and Beverage Center ZDBT240 monogram.com Safety Information BEFORE YOU BEGIN: Read these instructions completely and carefully. IMPORTANT
More informationL900 series USER MANUAL
INTRODUCTION The BLUGUARD Control Panel is designed for simple operation yet provides the maximum protection for you. Please read this manual carefully and follow the instructions contained in this book.
More informationAPCTMDT. Specs 1. Basic Description 1. Installation 2. Factory Settings 2. Overview 3. Button functions 4-5. How to customize settings 6-9
Specs 1 Basic Description 1 Installation 2 Factory Settings 2 Overview 3 Button functions 4-5 How to customize settings 6-9 Override function 9 What to connect 10 Q & A 11 Warnings 12 Warranty 15 Page
More informationGE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900
GE Monogram Installation Instructions with Optional Trim Kit Installation Instructions Built-In Dishwashers Models ZBD5600 ZBD5700 ZBD5900 Before you begin - Read these instructions completely and carefully.
More informationD14 & D18 Upright Vacuum
Operator's Manual D14 & D18 Upright Vacuum READ THIS BOOK This book has important information for the use and safe operation of this machine. Failure to read this book prior to operating or attempting
More informationMW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00
MW 3950 Pince courant de fuite Leakage current Clampmeter Notice d utilisation User s Manual M3950M00 Safety Information To ensure safe operation and service of the Tester, follow these instructions. Failure
More information