1 Product Information and Technical Guide Side by Side and Top Mount Refrigerators July December 2003 White-Westinghouse January 2004
2 TABLE OF CONTENTS Safe Servicing Practices Service Data Sheet, Refrigerant Charge & Energy Efficiency Rating Indexes Troubleshooting Guide Appendix A - Service Data Sheets A1 - A A3 - A A5 - A A7 - A A9 - A A11 - A A13 - A A15 - A A17 - A A19 - A A21- A22 1
3 SAFE SERVICING PRACTICES - ALL APPLIANCES To avoid personal injury and/or property damage, it is important that Safe Servicing Practices be observed. The following are some limited examples of safe practices: 1. DO NOT attempt a product repair if you have any doubts as to your ability to complete it in a safe and satisfactory manner. 2. Before servicing or moving an appliance: Remove the power cord from the electrical outlet, trip the circuit breaker to the OFF position, or remove the fuse. Turn off the gas supply. Turn off the water supply. 3. Never interfere with the proper operation of any safety device. 4. USE ONLY REPLACEMENT PARTS CATALOGED FOR THIS APPLIANCE. SUBSTITUTIONS MAY DEFEAT COMPLIANCE WITH SAFETY STANDARDS SET FOR HOME APPLIANCES. 5. GROUNDING: The standard color coding for safety ground wires is GREEN, or GREEN with YELLOW STRIPES. Ground leads are not to be used as current carrying conductors. It is EXTREMELY important that the service technician reestablish all safety grounds prior to completion of service. Failure to do so will create a hazard. 6. Prior to returning the product to service, ensure that: All electrical connections are correct and secure All electrical leads are properly dressed and secured away from sharp edges, high-temperature components, and moving parts All non-insulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal parts and panels All safety grounds (both internal and external) are correctly and securely connected All panels are properly and securely reassembled ATTENTION!!! This service manual is intended for use by persons having electrical and mechnical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. Electrolux Home Products, Inc. cannot be responsible, nor assume any liability, for injury or damage of any kind arising from the use of this manual Electrolux Home Products, Inc. 2
4 Model Service Data Sheet Charge Energy Efficiency Rating Brand E23CS75DSS Electrolux FRS23BH5CQ Frigidaire FRS23BH5CW Frigidaire FRS23BH6CB Frigidaire FRS23BH6CS Frigidaire FRS23F4CB Frigidaire FRS23F4CB Frigidaire FRS23F4CQ Frigidaire FRS23F4CQ Frigidaire FRS23F4CW Frigidaire FRS23F4CW Frigidaire FRS23H5ASB Frigidaire FRS23H7CB Frigidaire FRS23H7CQ Frigidaire FRS23H7CSB Frigidaire FRS23H7CW Frigidaire FRS23KF5CB Frigidaire FRS23KF5CB Frigidaire FRS23KF5CQ Frigidaire FRS23KF5CQ Frigidaire FRS23KF5CS Frigidaire FRS23KF5CW Frigidaire FRS23KF5CW Frigidaire FRS23KF6CB Frigidaire FRS23KF6CQ Frigidaire FRS23KF6CW Frigidaire FRS23R4CB Frigidaire FRS23R4CB Frigidaire FRS23R4CQ Frigidaire FRS23R4CQ Frigidaire FRS23R4CW Frigidaire FRS23R4CW Frigidaire FRS23W3AQ Frigidaire FRS23W3AW Frigidaire FRS26BH5CQ Frigidaire FRS26BH5CW Frigidaire FRS26BH6CB Frigidaire FRS26BH6CB Frigidaire FRS26BH6CB Frigidaire FRS26BH6CS Frigidaire FRS26BH6CW Frigidaire FRS26BH6CW Frigidaire FRS26F4CB Frigidaire FRS26F4CQ Frigidaire FRS26F4CW Frigidaire FRS26H5ASB Frigidaire FRS26H5ASB Frigidaire FRS26H5ASB Frigidaire FRS26H7CB Frigidaire FRS26H7CB Frigidaire FRS26H7CB Frigidaire FRS26H7CQ Frigidaire 3
5 Model Service Data Sheet Charge Energy Efficiency Rating Brand FRS26H7CQ Frigidaire FRS26H7CQ Frigidaire FRS26H7CSB Frigidaire FRS26H7CSB Frigidaire FRS26H7CSB Frigidaire FRS26H7CW Frigidaire FRS26H7CW Frigidaire FRS26H7CW Frigidaire FRS26HF6BB Frigidaire FRS26HF6BB Frigidaire FRS26HF6BQ Frigidaire FRS26HF6BQ Frigidaire FRS26HF6BW Frigidaire FRS26HF6BW Frigidaire FRS26HF7BB Frigidaire FRS26HF7BB Frigidaire FRS26HF7BQ Frigidaire FRS26HF7BQ Frigidaire FRS26HF7BW Frigidaire FRS26HF7BW Frigidaire FRS26KF5CB Frigidaire FRS26KF5CQ Frigidaire FRS26KF5CW Frigidaire FRS26KF6CB Frigidaire FRS26KF6CB Frigidaire FRS26KF6CB Frigidaire FRS26KF6CQ Frigidaire FRS26KF6CQ Frigidaire FRS26KF6CQ Frigidaire FRS26KF6CW Frigidaire FRS26KF6CW Frigidaire FRS26KF6CW Frigidaire FRS26KR4CB Frigidaire FRS26KR4CQ Frigidaire FRS26KR4CW Frigidaire FRS26LF8CB Frigidaire FRS26LF8CQ Frigidaire FRS26LF8CS Frigidaire FRS26LF8CW Frigidaire FRS26LR5CB Frigidaire FRS26LR5CQ Frigidaire FRS26LR5CW Frigidaire FRS26R2AQ Frigidaire FRS26R2AW Frigidaire FRS26R4CB Frigidaire FRS26R4CQ Frigidaire FRS26R4CW Frigidaire FRS26RBCW Frigidaire FRS26RLECS Frigidaire FRS26W2AW Frigidaire FRS26W2BSB Frigidaire FRT14A2AW Frigidaire 4
6 Model Service Data Sheet Charge Energy Efficiency Rating Brand FRT14A2AZ Frigidaire FRT15B1BW Frigidaire FRT15B3AQ Frigidaire FRT15B3AT Frigidaire FRT15B3AW Frigidaire FRT15B3AZ Frigidaire FRT15G4BQ Frigidaire FRT15G4BW Frigidaire FRT15G5CSB Frigidaire FRT15G5CSK Frigidaire FRT15HB3AQ Frigidaire FRT15HB3AW Frigidaire FRT15HB3AZ Frigidaire FRT17A2AQ Frigidaire FRT17A2AW Frigidaire FRT17A2AZ Frigidaire FRT17B3AQ Frigidaire FRT17B3AT Frigidaire FRT17B3AW Frigidaire FRT17B3AZ Frigidaire FRT17G4BD Frigidaire FRT17G4BQ Frigidaire FRT17G4BW Frigidaire FRT17HB3CW Frigidaire FRT18B1BW Frigidaire FRT18B4AQ Frigidaire FRT18B4AT Frigidaire FRT18B4AW Frigidaire FRT18B4AZ Frigidaire FRT18B5AB Frigidaire FRT18B5AW Frigidaire FRT18B5AWA Frigidaire FRT18B6CB Frigidaire FRT18G4AQB Frigidaire FRT18G4AWB Frigidaire FRT18G5AQA Frigidaire FRT18G5AWA Frigidaire FRT18G7CW Frigidaire FRT18H6CSB Frigidaire FRT18H6CSK Frigidaire FRT18H7CW Frigidaire FRT18HS6AWA Frigidaire FRT18IB4AW Frigidaire FRT18IG4AQ Frigidaire FRT18IG4AT Frigidaire FRT18IG4AW Frigidaire FRT18IG4AZ Frigidaire FRT18KB2CW Frigidaire FRT18KG3CW Frigidaire FRT18LN5BQ Frigidaire FRT18LN5BQ Frigidaire FRT18LN5BW Frigidaire 5
7 Model Service Data Sheet Charge Energy Efficiency Rating Brand FRT18LN5BW Frigidaire FRT18LR7AQA Frigidaire FRT18LR7AWA Frigidaire FRT18P6BSB Frigidaire FRT18P6BSK Frigidaire FRT18P6CQ Frigidaire FRT18P6CQ Frigidaire FRT21BH8CB Frigidaire FRT21BH8CS Frigidaire FRT21BH8CW Frigidaire FRT21C5AQ Frigidaire FRT21C5AQ Frigidaire FRT21C5AW Frigidaire FRT21C5AW Frigidaire FRT21FG3CQ Frigidaire FRT21FG3CQ Frigidaire FRT21FG3CW Frigidaire FRT21FG3CW Frigidaire FRT21FG4CQ Frigidaire FRT21FG4CW Frigidaire FRT21H7ASB Frigidaire FRT21H7ASK Frigidaire FRT21H8CB Frigidaire FRT21H8CQ Frigidaire FRT21H8CSB Frigidaire FRT21H8CSK Frigidaire FRT21H8CW Frigidaire FRT21HR6AB Frigidaire FRT21HR6AQ Frigidaire FRT21HR6AW Frigidaire FRT21IS6BB Frigidaire FRT21IS6BB Frigidaire FRT21IS6BQ Frigidaire FRT21IS6BQ Frigidaire FRT21IS6BW Frigidaire FRT21IS6BW Frigidaire FRT21KG3CQ Frigidaire FRT21KG3CW Frigidaire FRT21KG3CW Frigidaire FRT21LR7AB Frigidaire FRT21LR7AW Frigidaire FRT21P5AB Frigidaire FRT21P5AB Frigidaire FRT21P5AQ Frigidaire FRT21P5AQ Frigidaire FRT21P5AW Frigidaire FRT21P5AW Frigidaire FRT21P6CQ Frigidaire FRT21P6CQ Frigidaire FRT21P6CSB Frigidaire FRT21P6CSB Frigidaire FRT21P6CSK Frigidaire 6
8 Model Service Data Sheet Charge Energy Efficiency Rating Brand FRT21P6CSK Frigidaire FRT21P6CW Frigidaire FRT21P6CW Frigidaire FRT21S6AB Frigidaire FRT21S6AB Frigidaire FRT21S6AQ Frigidaire FRT21S6AW Frigidaire FRT21S6AW Frigidaire GLHS237ZCB Frigidaire GLHS237ZCQ Frigidaire GLHS237ZCW Frigidaire GLHS269ZCB Frigidaire GLHS269ZCB Frigidaire GLHS269ZCQ Frigidaire GLHS269ZCQ Frigidaire GLHS269ZCW Frigidaire GLHS269ZCW Frigidaire GLRS237ZCB Frigidaire GLRS237ZCQ Frigidaire GLRS237ZCW Frigidaire GLRS267ZCB Frigidaire GLRS267ZCQ Frigidaire GLRS267ZCW Frigidaire GLRT184TCB Frigidaire GLRT184TCB Frigidaire GLRT184TCQ Frigidaire GLRT184TCQ Frigidaire GLRT184TCW Frigidaire GLRT184TCW Frigidaire GLRT214TCB Frigidaire GLRT214TCB Frigidaire GLRT214TCQ Frigidaire GLRT214TCQ Frigidaire GLRT214TCW Frigidaire GLRT214TCW Frigidaire GRS23R4CQ Gibson GRS23R4CW Gibson GRS23R4CW Gibson GRS26R4CQ Gibson GRS26R4CQ Gibson GRS26R4CW Gibson GRS26R4CW Gibson GRT15B3BW Gibson GRT17B3BQ Gibson GRT17B3BW Gibson GRT17G4BQ Gibson GRT17G4BW Gibson GRT18C6AQ Gibson GRT18C6AW Gibson GRT18C6AW Gibson GRT18S6AW Gibson GRT18S6AW Gibson 7
9 Model Service Data Sheet Charge Energy Efficiency Rating Brand GRT21G3CQ Gibson GRT21G3CW Gibson GRT21S6CQ Gibson GRT21S6CW Gibson GRT21S6CW Gibson GS18HTZCQ Gibson GS18HTZCSB Gibson GS18HTZCW Gibson GS21HTZCB Gibson GS21HTZCB Gibson GS21HTZCC Gibson GS21HTZCC Gibson GS21HTZCK Gibson GS21HTZCQ Gibson GS21HTZCQ Gibson GS21HTZCW Gibson GS23HSZCB Gibson GS23HSZCQ Gibson GS23HSZCW Gibson GS26HSZCB Gibson GS26HSZCC Gibson GS26HSZCC Gibson GS26HSZCC Gibson GS26HSZCC Gibson GS26HSZCQ Gibson GS26HSZCQ Gibson GS26HSZCQ Gibson GS26HSZCW Gibson GS26HSZCW Gibson PLHS237ZCB Frigidaire PLHS239ZCB Frigidaire PLHS267ZCB Frigidaire PLHS267ZCB Frigidaire PLHS268ZCB Frigidaire PLHS268ZCB Frigidaire PLHS268ZCB Frigidaire PLHS269ZCB Frigidaire PLHS269ZCB Frigidaire PLHT189CSB Frigidaire PLHT189CSK Frigidaire PLHT219TCB Frigidaire PLHT219TCK Frigidaire PLHT219TCK Frigidaire WRS23MF5AS White Westinghouse WRS23MW3AQ White Westinghouse WRS23MW3AW White Westinghouse WRS23MW3AW White Westinghouse WRS23W0AW White Westinghouse WRS23W0AW White Westinghouse WRS26MF5AS White Westinghouse WRT15MG4BQ White Westinghouse WRT15MG4BW White Westinghouse 8
10 Model Service Data Sheet Charge Energy Efficiency Rating Brand WRT15MG4BW White Westinghouse WRT17MG4BQ White Westinghouse WRT17MG4BW White Westinghouse WRT17MG4BW White Westinghouse WRT18A0AW White Westinghouse WRT18MP5AQ White Westinghouse WRT18MP5AQA White Westinghouse WRT18MP5AQB White Westinghouse WRT18MP5AW White Westinghouse WRT18MP5AWB White Westinghouse WRT21MG3AQ White Westinghouse WRT21MG3AQ White Westinghouse WRT21MG3AW White Westinghouse WRT21S4AW White Westinghouse WRT21S4AW White Westinghouse 9
11 TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION Compressor will not run. Compressor runs but does not cool. No voltage at wall receptacle. Service cord defective or unplugged at wall receptacle. Low voltage causing compressor to cycle on overload. Control thermostat knob in OFF position. Inoperative control thermostat. Compressor stuck. Compressor windings open. Defrost timer stuck in defrost mode. ADC (Adaptive Defrost Control) not turning on compressor after defrost. Compressor overload stuck open. Relay lead loose. Relay loose or inoperative. Service cord pulled out of harness. Faulty cabinet wiring. Check circuit breaker, fuse or GFCI (Ground Fault Circuit Interruptor - It is not recommended to connect your refrigerator to a GFCI.) Check service cord. Voltage fluctuation should not exceed ± 10% of vac ( ) Turn control thermostat knob to ON position. Replace control thermostat Replace compressor. Replace compressor. Replace defrost timer. (if equipped) Replace ADC. Replace compressor overload. (if equipped compressor starter relay & overload may be plugged into each other) Repair or replace lead. Repair or replace relay. (if equipped) Repair connection. Repair wiring. System out of refrigerant. Check for leaks. * Compressor not pumping. Replace compressor. * Restricted filter drier. Replace filter drier. * Restricted capillary tube. Replace heat exchanger and evaporator assembly. Moisture in system. See NOTE. * * NOTE: Repair or replace component that is leaking. Replace the compressor if the system is contaminated. Blow out remaining part of system with dry Nitrogen. Pump down and recharge per listing on product serial label. Always replace filter drier when repairing sealed system. 10
12 PROBLEM CAUSE SOLUTION Compressor short cycles. Compressor runs too much. Noisy. Erratic control thermostat. Faulty relay. Restricted air flow over condenser. Low voltage fluctuation exceeds ± 10% of vac ( ). Compressor draws excessive watts. Inoperative condenser fan motor. Control thermostat is erratic or not properly set. Refrigerator exposed to high heat. (110 or higher) High room temperature. (110 F or higher) Low pumping capacity compressor. Door gaskets not sealing. Replace control thermostat. Replace relay or starter. Ensure air flow is unobstructed over condenser. Call qualified electrician. Replace compressor. Replace condenser fan motor. Replace control thermostat or reset to normal position. Move refrigerator to cooler location. Advise customer not to install refrigerator where temperature will rise above 110 F because compressor will not maintain proper temperatures. Replace compressor. System undercharged. Check for leaks. * System overcharged. Adjust doors or replace door gaskets. Charge per listing on product serial plate. * Interior light stays on. Check door switch and door adjustment. Contaminants in system. Capillary tube kinked or partially restricted. Flush out system. Replace filter drier, evacuate, and recharge. * Replace heat exchanger and evaporator assembly. * Filter drier partially restricted. Replace filter drier. * Refrigerator and/or freezer compartment overloaded poor air circulation Restricted air flow over condenser. Condenser fan motor is inoperative. (Forced air condenser models only) Tubing vibrates. Internal compressor noise. Loose parts. Compressor operating at high head pressure due to restricted air flow over condenser. Advise customer. Ensure air flow is unobstructed over condenser. Replace condenser fan motor. Adjust tubing. Replace compressor. Check shelving. Ensure air flow is unobstructed over condenser. * See NOTE at bottom of page 10 11
13 PROBLEM CAUSE SOLUTION Freezer compartment too warm. Fig. A Freezer compartment too cold. * See NOTE at bottom of page 10 Inoperative evaporator fan motor. Improperly positioned fan blade. 12 Check wiring and evaporator fan motor. (Check ADC on Side-by-Sides.) Position fan blade properly. See Figure A. Evaporated frosted up. Check defrost system, door adjustments, and door gaskets. Inoperative condenser fan motor. (Forced air condenser models only) Restricted air flow over condenser On static condensers, be sure you have 1 between condenser and wall, and 3 over top, or 1 side of condenser is clear. Freezer compartment overloaded poor air circulation. Low room temperature. (60 or lower, 55 for models with Service Data Sheet numbers and ) Freezer or refrigerator compartment doors left open. Control thermostat out of calibration. Door gaskets not sealing. Control thermostat capillary tube improperly positioned. Replace condenser fan motor. Clean condenser. (Dynamic models only.) Advise customer. Advise customer not to install refrigerator where temperature will drop below 60 F. Compressor will not maintain proper temperatures. Advise customer. Replace control thermostat. Shortage of refrigerant. Check for leaks. * Restricted filter drier or capillary tube. Evaporator fan motor covered in ice. Inoperative cold control. (Top mount-no Frost or Side-by-Side freezer cold control) Freezer compartment inlet air duct is loose or restricted. Door is loose. Food compartment air return duct blocked (Top Mount only) Diffuser (foam block) in top of food compartment is broken. (Foam block located in control housing for models with Service Data 5 Sheets and ) Adjust doors or replace door gaskets. Reposition temperature sensing element. Check for leaks and burnt compressor windings. * Check seal around ice maker fill spout. Check seal between evaporator cover and liner. (Side-by-sides only) Replace cold control. Re-install air duct or remove obstruction from inlet air duct. Adjust door. If foam block is frozen, replace block. If duct is blocked, remove obstruction. Replace diffuser. (Top Mount only) Freezer compartment cold control installed incorrectly. (Side-by-Sides only)
14 PROBLEM CAUSE SOLUTION Refrigerator compartment too warm. Refrigerator compartment too cold. Inoperative evaporator fan motor. Improperly positioned fan blade. Check wiring and evaporator fan motor. (Check ADC on Side-by-Sides.) Position fan blade properly. See page 12, Figure A. Evaporated frosted up. Check defrost system, door adjustments, and door gaskets. Refrigerator compartment overloaded poor air circulation. Low room temperature. (60 or lower, 55 for models with Service Data Sheet numbers and ) Freezer or refrigerator compartment doors left open. Damper control out of calibration or not opening. Advise customer. Advise customer not to install refrigerator where temperature will drop below 60 F. Compressor will not maintain proper temperatures. Advise customer. Replace damper control. Shortage of refrigerant. Check for leaks. * Restricted filter drier or capillary tube. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Freezer compartment return air duct restricted. Control thermostat knob set at too warm a position. Inoperative or erratic refrigerator/freezer compartment door switch. Freezer compartment inlet air duct is loose or restricted. Door is loose. Food compartment air return duct blocked (Top Mount only) Inoperative cold control. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Diffuser (foam block) in top of food compartment is broken. (Foam blocked located in control housing for models with Service Data Sheet numbers and ) Check for leaks and burnt compressor windings. * Re-install air duct or remove obstruction from air duct. Adjust door. Remove obstruction from return air duct. Set control knob to a colder position. Replace door switch. Re-install air duct or remove obstruction from inlet air duct. Adjust door. If foam block is frozen, replace block. If duct is blocked, remove obstruction. Replace cold control. Re-install air duct or remove obstruction from air duct. Adjust door. Replace diffuser. (Top Mounts only) * See NOTE at bottom of page
15 PROBLEM CAUSE SOLUTION Refrigerator compartment too cold. (Continued) Evaporator blocked with ice. (See Adaptive defrost Control below for models with Service Data Sheet numbers and ) Frozen drain. Adaptive Defrost Control (ADC) not responding correctly. Inoperative cold control. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Diffuser (foam block) in top of food compartment is broken. (Foam blocked located in control housing for models with Service Data Sheet numbers and ) Door in damper control not closing or not closing all the way. Cold air blowing into food compartment with damper door closed all the way. Inoperative defrost timer. Defrost thermostat terminates too early. Thermostat is open. Refrigerator/Freezer compartment doors left open. Open defrost heater. Air leak around ice maker fill tube, or opening. Ice maker water line and wiring harness openings not sealed. Drain trough not properly formed. Divider (foam block) frozen. Faulty ADC board. Bad wire between ADC, defrost heater, and limiter. Replace cold control. Re-install air duct or remove obstruction from air duct. Adjust door. Replace diffuser. (Top Mounts only) Replace damper control. Check freezer control bulb for correct positioning to ensure it is installed correctly. Check foam seal between damper housing and cabinet liner. Check to see that the control box is mounted flush against the cabinet liner. Check wiring. Repair or replace defrost timer. Check for correct positioning of defrost thermostat. Repair or replace. Advise customer. Replace heater. Seal with permagum. Seal water line and wiring harness openings. Ensure drain trough is at 90 angle to back of freezer and that lip is up on front and ends. Replace divider. Check drain trough. Replace ADC board. Check wiring and wiring connectors. 14
16 PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to to 185 (Running) 1.1 to to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A ', 15' & 17' 25 F -4 C 47 F 8 C Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO THERMOSTAT C RED YEL NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE
17 Pictorial Schematic Ladder Schematic A - 2 Compressor Wiring 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor Kit * Starter/PTC * Run Capacitor * Control Timer (if applicable) N/A N/A N/A ADC (if applicable) N/A N/A N/A N/A N/A Defrost Kit Defrost Thermostat Kit Evaporator Fan Motor Condenser Fan Motor N/A N/A * Typical compressor kit includes compressor, electrical components, and filter-drier
18 PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to to 185 (Running) 1.1 to to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A ', 15' & 17' 25 F -4 C 47 F 8 C Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO THERMOSTAT C RED YEL NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE
19 Pictorial Schematic Ladder Schematic NOTE: DENOTES NOT ON ALL MODELS A - 4 COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * Starter/PTC * Run Capacitor * Relay N/A N/A N/A N/A N/A N/A Overload N/A N/A N/A N/A N/A N/A Control Timer (if applicable) ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit Defrost Thermostat Kit Evaporator Fan Motor Condenser Fan Motor N/A N/A
20 PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to to 185 (Running) 1.1 to to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A ', 15' & 17' 25 F -4 C 47 F 8 C Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO THERMOSTAT C RED YEL NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE
21 Pictorial Schematic Ladder Schematic A - 6 NOTE: DENOTES NOT ON ALL MODELS COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * Starter/PTC * N/A N/A N/A Run Capacitor * N/A N/A N/A Relay N/A N/A N/A N/A N/A Overload N/A N/A N/A N/A N/A Control Timer (if applicable) ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit Defrost Thermostat Kit Evaporator Fan Motor Condenser Fan Motor N/A N/A * Typical compressor kit includes compressor, electrical components, and filter-drier
22 PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to to 185 (Running) 1.1 to to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A ', 15' & 17' 25 F -4 C 47 F 8 C Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO THERMOSTAT C RED YEL NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE
23 Pictorial Schematic Ladder Schematic A - 8 NOTE: COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * Starter/PTC/TSD * N/A N/A N/A Run Capacitor * N/A N/A N/A Relay N/A N/A N/A N/A N/A Overload N/A N/A N/A N/A N/A Control Timer (if applicable) ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit Defrost Thermostat Kit Evaporator Fan Motor Condenser Fan Motor N/A N/A * Typical compressor kit includes compressor, electrical components, and filter-drier
24 PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 32 to 40% 55 to 65% Freezer Refrigerator L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 130 to 155 psig 896 to 1069 kpa (Last 1/3 of cycle) 120 to to 160 (Running) 1.2 to to 1. 5 B ase Voltage vac (127 vac max) vac (127 vac max) SERVICE DATA SHEET R134a ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE MODELS IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Cabinet Size DEFROST SPECIFICATIONS Cut-in 23' & 26' 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 9 Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time. CONDENSER FAN MOTOR RPM CW Opposite Shaft.1 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical vac (127 vac max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO THERMOSTAT C RED YEL NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE
25 A CUBIC FOOT 26 CUBIC FOOT SERVICE PARTS STANDARD E-STAR STANDARD E-STAR Compressor Kit * Starter/PTC * Run Capacitor * Temp. Control-Refr Temp. Control-Frzr Timer (if applicable) N/A N/A N/A N/A ADC (if applicable) Defrost Kit Defrost Thermostat Kit Evaporator Fan Motor Condenser Fan Motor * Typical compressor kit includes compressor, electrical components, and filter-drier
26 PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 32 to 40% 55 to 65% Freezer Refrigerator L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 130 to 155 psig 896 to 1069 kpa (Last 1/3 of cycle) 120 to to 160 (Running) 1.2 to to 1. 5 B ase Voltage vac (127 vac max) vac (127 vac max) SERVICE DATA SHEET R134a ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE MODELS IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Cabinet Size DEFROST SPECIFICATIONS Cut-in 23' & 26' 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 11 CONDENSER FAN MOTOR RPM CW Opposite Shaft.1 Running SPECIFICATIONS E lectrical vac (127 vac max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 165 P-3 Wire CONNECTOR PLUG CONNECTIONS Number W ire Color Connects to: P-4 1 Green/Yellow 2 Yellow 3 Black Ground Water Valve Line GREEN/YELLOW GREEN/YELLOW P-1 P-2 4 Lt. Blue Neutral
Product Information and Technical Guide
Product Information and Technical Guide Side by Side and Top Mount Refrigerators January 2004 - March 2004 White-Westinghouse 5995413308 July 2004 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------
More informationProduct Information and Technical Guide
Product Information and Technical Guide Side by Side and Top Mount Refrigerators April 2004 - December 2004 White-Westinghouse 5995427241 January 2005 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------
More informationProduct Information and Technical Guide
Product Information and Technical Guide Side by Side and Top Mount Refrigerators January 2005 - June 2005 White-Westinghouse 5995449906 October 2005 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------
More informationARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !
Amana Technical Information³Refrigerator ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 Due to a possibility of personal injury
More informationProduct Information and Technical Guide
Product Information and Technical Guide 2004 Room Air Conditioners MS2 and Compact 2 Models Safe Servicing Practices 3 Model Specifications 4-11 Compressor Overloads 12 Restrictor Tube Data 12 Receptacle
More informationCAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING
Amana Technical Information³Refrigerator P1303511W Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. Refer
More informationNOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control
SERVICE DATA SHEET 318047418 (0504) Rev. A Electric Wall Oven with Electronic Oven Control NOTICE This service data sheet is intended for use by persons having electrical and mechanical training and a
More informationElectrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)
Electrical Problems Fuse(s) blow or circuit breaker trips Does the unit use circuit breakers or fuses? Fuse(s) Circuit breakers Are the fuses dual element time delay? Is the circuit breaker HACR rated?
More informationTable of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5
Introduction The Scotsman Compact Refrigerator is a unique product, capable of being built into a cabinet because of its front vented, forced-air cooling system. It s also designed to be a companion to
More informationFFTR1514TW.jpg DRFFTR1514TB0.wmf CAWWTR1611SW0.wmf SHFFTR1614RW0.wmf SYFFTR1514RB1.wmf W eps S eps
Product No. B0 W0 Series R134a R134a Color black white Volts 115 115 Wiring Diagram 241582401 241582401 Owner's Guide A04555602 A04555602 Market North America North America Energy Guide A01298702 A10298702
More informationAPARTMENT MAINTENANCE SERIES
ORPORATION CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS AM-4 APARTMENT MAINTENANCE SERIES TOP-MOUNT REFRIGERATOR/FREEZERS OLD DESIGN 14 cu. ft. MULLION EVAPORATOR DESIGN 12 cu. ft. NEW DESIGN 14
More informationTable of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6
INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4
More informationVolts 115 Wiring Diagram Owner's Guide Energy Guide Service Data Sheet Installation Instructions
White-Westinghouse Product No. Series R134a System Color white Volts 115 Wiring Diagram 241582401 Owner's Guide 241997501 Market North America Energy Guide 241613796 Service Data Sheet 241588203 Installation
More informationProduct Information and Technical Guide
Product Information and Technical Guide 2005 Room ir Conditioners Model Year Designation P Example FS5P1 ThruTheWallExample FH085P1T Slider CasementExmaple FK104P1V Safety update 3 Safe Servicing Practices
More informationFast Track Troubleshooting
Fast Track Troubleshooting Models Covered: RF266AD**/XAA French Door Refrigeration IMPORTANT SAFETY NOTICE For Technicians Only This service data sheet is intended for use by persons having electrical,
More information! WARNING CAUTION DANGER WARNING CAUTION
CAUTION DANGER CAUTION ESU F 15 J W A U F 7 0 K W Series H J Storage Capacity 12 Cubic Foot 15 Cubic Foot 17 Cubic Foot 20 Cubic Foot Defrost Type Blank Manual F Free-O-Frost Color W White Product ESU
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING
More informationTROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION
GENERAL TROUBLESHOOTING Compressor Conditioning system OFF Turn ON conditioning system will not run No electrical power Check fuses Wrong voltage to applied to unit Compressor internal overload tripped
More informationPOLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL
POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 37 75-07 Corso Lino Zanussi, 30 060824 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434
More informationDue to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.
Bottom Mount Refrigerator Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTION
More informationEBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationπ H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY
π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure
More informationSERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR
R-122 SERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR WRT138FZDB**, WRT138FZDM**, WRT138FZDW** *All Engineering Versions W10881764 FORWARD This Whirlpool Service Manual, (Part No. W10881764), provides
More informationSERVICE DATA SHEET (9704) Rev. D
SERVICE DATA SHEET 318047401 (9704) Rev. D Electric Wall Ovens with Electronic Oven Control (ERC III - 318010700 & 318010900) NOTICE This service data sheet is intended for use by persons having electrical
More informationCAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS
Domestic Washer Technical Information 120 V, 60 Hz Models SAV2555AW* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
More informationService Manual Electric Cooktop
Service Manual Electric Cooktop 318 202 105 (0311) THIS IS A BLANK PAGE Table of Contents I SAFE SERVICING PRACTICES... 1 PRODUCT FEATURES... 2 WIRING DIAGRAM... 3 SECTION A - INSTALLATION... 4 CUT-OUT
More informationGlass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69
Commercial Refrigerator And Freezer User s Manual Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69 12/2015 Please read the manual thoroughly prior to equipment
More informationMANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R
MANUAL Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R LAST REVISION JULY 2009 INDEX Handling... 3 Installation... 4
More informationIMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.
73105 IMPORTANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service
More informationTable of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)
Table of Contents Refrigeration Cycle Service Procedures Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Solving Problems Identifying Low System Charge (9-11) Identifying High
More informationCAUTION. No-Load Performance, Controls in Normal Position
Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*
More informationPROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N
PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationRepair Parts List REFRIGERATOR MODEL NUMBER GT15B83V. When requesting service or ordering parts, always provide the following information:
Repair Parts List REFRIGERATOR MODEL NUMBER GT15B83V When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationCHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX
CHEST FREEZER INSTRUCTION MANUAL Model No.: EWCF5WBX EWCF7WBX To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this appliance.
More informationJBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0
Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility
More informationInstruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.
Instruction Manual Chest Freezer Model: ACFM050ADB INSTALLATION INSTRUCTIONS Before Using Your Freezer Remove the exterior and interior packing. Check to be sure you have all of the following parts: 1
More informationOperation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.
Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause
More informationNorcold Repair Guide for Ice Maker
Norcold Repair Guide for Ice Maker Section 10 Table of Contents Page: 10-2 General Description 10-2 Refrigerator Specifications 10-2 Refrigerator Operating Limits 10-2 Refrigerator Current Draws 10-2 Ice
More informationCABINET PARTS For Models: ET21MMXJW01, ET21MMXJT01 (White) (Biscuit)
CABINET PARTS REFRIGERATOR 11 00 Litho In U.S.A. (cre) 1 Part No. CABINET PARTS 1 LITERATURE PARTS LIT2201079 Service & Wiring Sheet LIT2212437 Energy Label LIT2205266 Use & Care Guide 2 2189410 Hinge
More informationFOR SERVICE TECHNICIAN S USE ONLY
F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform
More informationKAR-5 TECHNICAL EDUCATION KUWS246 WINE CELLAR JOB AID
KAR-5 TECHNICAL EDUCATION KUWS246 WINE CELLAR I JOB AID 4317201 INTRODUCTION This Job Aid, KUWS246 WINE CELLAR, (Part No. 4317201), has been compiled to provide the most recent information on design, features,
More informationGENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions
GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading
More informationAFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION
Bottom Mount Refrigerator Technical Information AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0! CAUTION Due to a possibility of personal injury or property damage, always contact an authorized technician
More informationFast Track Troubleshooting
Fast Track Troubleshooting Models Covered: RS267TDBP/XAA RS267TDPN/XAA RS267TDRS/XAA RS267TDWP/XAA NOTICE: RS267TD PN & RS Colors Parts Change: Refer to bulletin. Door Handle Parts Change IMPORTANT SAFETY
More informationImage Key Part Number Description Substitution Qty.
Model Number: BOM/Serial #: Graphic Title: XRSR465BW PXRSR465BW0 SUPPLEMENTAL INFORMATION Image Key Part Number Description Substitution Qty. 1 1 67002385 HARNESS-CONTROL 1 1 1 67002384 HARNESS, ICE MAKER
More informationUNIVERSAL SATELLITE DEVICE MINI - CAN VENDOR
UNIVERSAL SATELLITE DEVICE MINI - CAN VENDOR MODEL 3043-U SERVICE MANUAL July, 97 P/N 4208277 Rev. A TABLE OF CONTENTS INTRODUCTION...1 SPECIFICATIONS...1 General...1 Electrical...1 Capacity...1 Pricing...1
More informationFast Track Troubleshooting
Fast Track Troubleshooting Publication # tsrs265td Revision Date 03/30/2011 Models Covered: RS265TDBP/XAA RS265TDPN/XAA RS265TDRS/XAA RS265TDWP/XAA IMPORTANT SAFETY NOTICE For Technicians Only This service
More informationBeverage Air IMPORTANT
Beverage Air IMPORTANT INFORMATION FOR CT96 MODEL This cooler has passed the QUALITY CONTROL INSPECTION And meets the high standards for Beverage-Air Refrigeration products IMPORTANT PLEASE RETAIN FOR
More informationUSER GUIDE. TL6015W TL6018W 60cm Larder
USER GUIDE TL6015W TL6018W 60cm Larder Thank you for buying this high quality appliance This handbook is designed to help you through each step of owning your new appliance, from installation to use. Please
More informationFast Track Troubleshooting
Fast Track Troubleshooting Models Covered: RS267TDBP/XAA RS267TDPN/XAA RS267TDRS/XAA RS267TDWP/XAA Publication # tsrs267td Revision Date 03/30/2011 IMPORTANT SAFETY NOTICE For Technicians Only This service
More informationKM-61BAH KM-101BAH KM-151BAH
NO. M006-749 ISSUED: FEB. 18, 2008 REVISED: JUN. 12, 2008 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER MODEL KM-61BAH KM-101BAH KM-151BAH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt
More informationPHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions
PHOENIX 200 MAX LOW GRAIN REFRIGERANT HIGH CAPACITY DEHUMIDIFIER Table of Contents Therma-Stor Products Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 Phoenix 200 Max Operation
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513
TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before
More informationFast Track Troubleshooting
Models Covered: RF266AA**/XAA RF266AB**/XAA RF266**/XAA French Door Refrigeration NOTICE: RF266AA & AB** 01/09 Parts Change: Refer to bulletin. All Water Tank Parts Forced Mode: Press the Pwr Freeze Fridge
More informationV Refrigeration Module
5800 115V Refrigeration Module Removal and Replacement Instruction Sheet 60-4702-048 Revision F, January 25, 2016 These instructions cover the 4700 and 5800 115V refrigerator module replacement. Before
More informationCABINET PARTS REFRIGERATOR. For Models:ET21PKXGW03, ET21PKXGT03 (White) (Biscuit) Part No Litho In U.S.A. (cre) 1
CABINET PARTS REFRIGERATOR 9 00 Litho In U.S.A. (cre) 1 Part No. CABINET PARTS 1 LITERATURE PARTS LIT2201079 Service & Wiring Sheet LIT2205481 Energy Label LIT2205266 Use & Care Guide 2 2189410 Hinge (Top)
More informationWESTINGHOUSE REFRIGERATOR SIDE BY SIDE FROST FREE V SERIES
ELECTROLUX HOME PRODUCTS PTY LTD ABN 51 004 762 341 PRINT POST APPROVED PP565001/00099 Issue: 1 Technical Publication Nº RE 101 Book C27 Date: 2/04 WEB SITE ADDRESS: http://trade.partnship.com.au WESTINGHOUSE
More informationICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions
ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill
More informationV Refrigeration Module
5800 230V Refrigeration Module Removal and Replacement Instruction Sheet 60-4702-062 Revision F, January 25, 2016 These instructions cover the 4700 and 5800 230V refrigerator module replacement. Before
More informationDouble Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T
Double Door Over 70 Service Manual Models: F083975 NMTZH 821 F T F083973 NMTZH 822 F T Contents Parts Description...2 Circuit diagram...3 Cooling diagram...4 The guide for Disassembly Common parts of Refrigerator...5
More informationInstruction Manual. Chest Freezer MODEL: KI130CF2
Instruction Manual Chest Freezer MODEL: KI130CF2 INSTALLATION INSTRUCTIONS Before Using Your Freezer Remove the exterior and interior packing. Check to be sure you have all of the following parts: Storage
More informationFOR SERVICE TECHNICIAN S USE ONLY
FOR SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform
More information1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location
Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...
More informationCAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%
Bottom Mount Refrigerator Technical Information JBC2088HT* JBC2088HT*1, JBL2088HES JBL2088HES1, JBR2088HES JBR2088HES1, JFC2089HE* JFC2089HE*1, JFC2089HP* JFC2089HP*1, JFC2089HT* JFC2089HT*1, KBFA20ERBL
More informationFast Track Troubleshooting
Fast Track Troubleshooting Models Covered: RS263BBBB/XAA RS263BBSH/XAA RS263BBWP/XAA RS265LBBP/XAA RS265LBWP/XAA SxS Refrigeration Notice: Bulletin on parts change Thermal Fuse to Bi-Metal Publication
More informationUser s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1
User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1 Contents Introductions..................................................... 3 Important
More informationINSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.
INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates. Thank you for choosing Nova Kool for your refrigeration needs. For over 20 years we have been
More informationUNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions
UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill
More informationCABINET PARTS REFRIGERATOR. For Models: 8ET1FTKXKT00 (Biscuit) Litho In U.S.A. (mdg) 1. Part No
CABINET PARTS REFRIGERATOR 12 04 Litho In U.S.A. (mdg) 1 Part No. CABINET PARTS 1 LITERATURE PARTS LIT2201079 Service & Wiring Sheet LIT2200594 Use & Care Guide 2 2189410 Hinge (Top) 3 2166108 Roller Front
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com
More informationQuest Dry 105, 155, and 205 Dual
Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More informationKM-630MAH KM-630MWH KM-630MRH
NO.: ISSUED: 73114 JUNE 23, 2004 HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-630MAH KM-630MWH KM-630MRH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service or maintain this
More informationPOLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL
POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL www.polartemp.com TABLE OF CONTENTS Disclaimer.......................................... Page 3 Inspection and unpacking..............................
More informationFreightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)
www.dometic.com Freightliner Refrigerator Troubleshooting Guide For Before initiating troubleshooting, the following equipment is recommended: Multimeter, 20 gauge (min) wires to use as jumpers, and 12Vdc
More informationAutomatic Ice Maker. Service Manual VT ICEMAKER 15
Automatic Ice Maker Service Manual VT ICEMAKER 15 Table of contents How the Icemaker works 3 10 Cooling System 3 Water System 4 5 Wiring Connections and Controller 6 8 Exploding Drawing 9 10 TroubleShooting
More informationBottom Mount Refrigerator---Technical Information
Bottom Mount Refrigerator---Technical Information WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operation. Failure to do so can result in death
More informationCONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION
AIR SERIES SYSTEM INSTALLATION MANUAL CONTENTS CONSIDERATIONS General Plumbing Component Connection 2 2 2 ILLUSTRATION Control System 3 CONFIGURATION Voltage Verification 4 CONNECTION Component Connection
More informationSPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N
SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationFOR SERVICE TECHNICIAN S USE ONLY
F SERVICE TECHICIA S USE OY TE: This sheet contains important Technical Service Data. Tech Sheet Do ot Remove Or Destroy DAGER Electrical Shock Hazard Only authorized technicians should perform diagnostic
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A
TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338
TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!
More informationKELVINATOR REFRIGERATORS NO FROST H & SH SERIES
ELECTROLUX HOME PRODUCTS PTY LTD ABN 51 004 762 341 PRINT POST APPROVED PP565001/00099 Issue: 1 Technical Publication Nº RE 78 Book C26 Date: 1/04 WEB SITE ADDRESS: www.partnship.com.au KELVINATOR REFRIGERATORS
More informationPROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N
PROAIR Air Conditioner CR43 Model INSTRUCTION MANUAL Rev. H P/N 10-1008-130 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More information- 1 - Updated on 18 March, 2010
- 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION
More informationTROUBLESHOOTING VANGUARD
TROUBLESHOOTING VANGUARD IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring. WARNING: Disconnect electrical power to the Unit to prevent personal injury
More informationRepair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:
Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationIce Maker (Fresh Food Compartment)
Ice Maker (Fresh Food Compartment) The Ice Maker is located in the fresh food compartment in models featuring a dispenser in the left side door. Models without the dispenser will have the Ice Maker mounted
More informationREFRIGERATOR MODELS: WRT111SFAW00 (White) WRT111SFAB00 (Black) WRT111SFAF00 (Satina) 11/25/ Whirlpool Corporation Part No. W Rev.
REFRIGERATOR MODELS: WRT111SFAW00 (White) WRT111SFAB00 (Black) WRT111SFAF00 (Satina) 11/25/2013 2013 Whirlpool Corporation Part W10477546 Rev. D CABINET PARTS 11/25/2013 2 Part W10477546 Rev. D CABINET
More informationRoom Air Conditioner Service and Parts Manual
Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2
More informationCABINET PARTS REFRIGERATOR. For Models: GT2SHMXMS01 (Stainless Steel) Litho In U.S.A. (ebk) 1. Part No
CABINET PARTS REFRIGERATOR 12 03 Litho In U.S.A. (ebk) 1 Part No. CABINET PARTS 1 Literature Parts LIT2225762 Service & Wiring Sheet LIT2301830 Energy Label LIT2225411 Use & Care Guide LIT2225413 Customer
More informationOwner s Manual Ultimate 340
The World Leader in Carpet Cleaning, Restoration and Janitorial Supplies 1.800.400.9473 Owner s Manual Ultimate 340 Installation, Operation & Service Instructions Read and Save These Instructions The Ultimate
More informationRepair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:
Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationQuest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest CDG Dry 74 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationCABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)
CABINET PARTS REFRIGERATOR 1 12 Litho In U.S.A. (mlg)(bay) 1 Part No. Rev.A CABINET PARTS 1 Literature Parts W10402929 Service & Wiring Sheet 2316016 Use & Care Guide 628370 Modular Icemaker Service Sheet
More informationRPI Industries, Inc.
RPI Industries, Inc. AIR SCREEN and SELF-SERVE OPERATION AND SERVICE MANUAL WARRANTY INFORMATION For Models Stratus SCRFC48R-SSI SCRFC60R-SSI SCRFC72R-SSI SCRFC48R-SSII SCRFC72R-SSII SCRFC48R-SSIII SCRFC72R-SSIII
More informationSplit Floor-Mounted Cooling System Operation Care Installation Manual
Split Floor-Mounted Cooling System Operation Care Installation Manual CT14TSA CT13TSA CT12TSA CT34TSA CT1TSA CT14TSA-LA CT13TSA-LA CT12TSA-LA CT34TSA-LA CT1TSA-LA www.apexwinecellars.com Apex 17631 S Susana
More informationQuest 105, Dry155, and 205 Dual
Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationT-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N
T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE