Setting Your Bullseye to Control Your Fans

Size: px
Start display at page:

Download "Setting Your Bullseye to Control Your Fans"

Transcription

1

2 Setting Your Bullseye to Control Your Fans The AgriDry Bullseye Controller has four modes of operation. These modes are not selected but rather determined based on the settings in the controller. Each of the illustrations (for corn) below will help you understand what each setting is controlling. The four modes are: 1. Natural Air Drying 2. Low Temp Drying OR (CEMC Drying) 3. Changing Moisture 4. Storage (each season has different settings, see reverse) * The illustrations on the following pages are hypothetical and for the purposes of training. AgriDry does not promote introducing any foreign material to the grain in storage. Please reference owners manual for full description of the modes of operation Bullseye Operating Window Fans will not run when EMC (Blue Line) is outside the operating window (Shaded Area) Fans will run when EMC (Blue Line) is inside the operating window (Shaded Area) Current EMC Current Moisture Target Moisture Upper Limit Target Moisture Lower Limit EMC Limit Lower Changing Settings with ADLink Wizard The easiest way to set your controller is through the ADLink Grain Bin Wizard that can be found on your ADLink.com account General Settings screen. The wizard will assist you in setting your controller when you make MAJOR changes, like going from Drying to Storage Mode. The Wizard currently has suggested settings for grain types corn and soybeans. To save the changes to your controller, choose save and apply after you have updated your settings. For more information visit

3 Current Moisture (CM) Target Moisture (TM) +/- (Target) Moisture EMC Limit ON CEMC MIN 30 MAX 90 RH CNTRL TYPE NONE Current Moisture 18.0 Natural Air Drying Settings (TM ) 16.0 (TM ) 15.0 Moisture Lower Limit 10.5 **Fans will run when EMC or CEMC is between 10.5 and 18.0 as long as air temperature is between 30 degrees and 90 degrees Low Temp Drying Settings Current Moisture (CM) 18 Target Moisture (TM) /- (Target) Moisture 0.5 EMC Limit 5 CEMC MIN ON 30 MAX 90 RH CNTL TYPE HEAT CNTL TIMEOUT 60 (TM ) 16.0 (TM ) 15.0 Moisture Lower Limit 10.5 *Both Heaters and Fans will run any time both the EMC and the CEMC is above Heaters will continue to run until the CEMC reading hits **ONLY Fans will run when EMC is between 10.5 and 16.0 as long as air temperature is between 30 degrees and 90 degrees.

4 Current Moisture (CM) Target Moisture (TM) +/- (Target) Moisture EMC Limit CEMC MIN MAX RH CNTL TYPE Changing Moisture Settings ON NONE TM + EMC LIMIT Moisture Upper Limit 18.0 (TM ) 16.0 (TM ) 15.0 Current Moisture 14.5 **Fans will run when EMC is between 14.5 and 18.0 as long as air temperature is between 30 degrees and 90 degrees Fall Storage Mode Current Moisture (CM) 15.5 Target Moisture (TM) /- (Target) Moisture 2 EMC Limit 5 CEMC OFF MIN 30 MAX 60 Target Temp 45 +/- (Target) Temp RH CNTL TYPE (TM ) 17.5 (TM ) NONE ** Fans will run when the conditions below are true. EMC-CEMC Air Temp AVG GR TEMP > Air Temp If cooling AVG GR TEMP < Air Temp if warming AVG GR TEMP < 40 & > 50

5 Suggested Controller Settings Drying Storage CORN Natural Air Low Temp Winter Spring/Fall Summer GRAIN TYPE > CORN CORN CORN MIN AIR TEMP > MAX AIR TEMP > CUR MOISTURE > TGT MOISTURE > /- MOISTURE > EMC LIMIT > USE CEMC VAL > ON N/A ON mmm TGT TEMP > mmm +/- TEMP > mmm TEMP LIMIT > HOT SPOTTING > ON ON OFF TRIP DEGREES > DROP DEGREES > HOT TIMEOUT > RH CNTL TYPE > NONE HEAT None CNTL TIMEOUT > N/A 60 N/A Drying Storage SOYBEANS Natural Air Low Temp Winter Spring/Fall Summer GRAIN TYPE > SOYBEANS SOYBEANS SOYBEANS MIN AIR TEMP > MAX AIR TEMP > CUR MOISTURE > TGT MOISTURE > /- MOISTURE > EMC LIMIT > USE CEMC VAL > ON N/A ON mmm TGT TEMP > mmm +/- TEMP > mmm TEMP LIMIT > HOT SPOTTING > ON ON OFF TRIP DEGREES > DROP DEGREES > HOT TIMEOUT > RH CNTL TYPE > NONE HEAT NONE CNTL TIMEOUT > N/A 60 N/A Settings for 1 CFM per bu of airflow. These are recommended settings only and may differ from the manual. If you need help setting the controller please call: AgriDry Helpline

6

7 Frequently Asked Questions During Harvest Q: I m going to start harvesting in a few days- what should I do with my controller to get it ready for fall? A: The controller should be powered up at least a week in advance before you fill the bin. Check the outside air temperature, relative humidity, grain temperatures, etc. to make sure they are reading properly. If there is a satellite modem being used on the controller, wait at least 24 hours before checking the data on MD or ADLink website. Any questions for incorrect readings or data, call AgriDry ( ). Also, verify the temperature cable is secured to the grain bin floor with a temp cable magnet, light string, twine, or fish line to prevent the cable from moving to the outside wall. Q: We had a wet fall and my grain is wet when putting it into the bin. Will my controller still work for drying my grain? A: The controller can be set to automatically control the fans/low temperature burners as soon as there are a few feet of grain in the bin. With 1 CFM per bushel, the maximum moisture can be 22% or less. IF the grain moisture is higher than 22%, the airflow needs to be 2 CFM per bushel. With the correct grain depth, the controller can automatically run the fan/low temperature burners to correctly dry the grain to the desired target moisture. Q: It is rainy and foggy out, should my fans be running? A: The fan operation is based on the controller settings you ve chosen for your grain. To dry corn to 18% moisture the relative humidity can be about 85%, When the weather fronts change, the humidity sensor does not change immediately and the ground conditions need to become saturated for the relative humidity to rise above 85%. In saying this, the fans may run when it starts raining but will shut down if the relative humidity climbs above 85%. Q: What s the difference between drying mode and storage mode? How do I know which mode to be in? A: DRYING MODE: is used if your grain moisture is higher than your target moisture. STORAGE MODE: monitors the average grain temperature and compared it to the target temperature window. Use storage mode if the moisture of the grain is to your target moisture window.

8 Q: My corn is over dry on the bottom of the bin and still wet on the top. What do I do? A: The EMC Limit setting under the Moisture Control menu on the controller prevents the controller from running when the relative humidity is very low, hence over dry grain. To bring back some moisture in the bottom and keep drying the top, lower the EMC limit number (maybe ) and increase your current moisture setting to two points above its current number. Q: My incoming grain is at the desired moisture, how can I use the controller to benefit my grain? A: Set the controller seatings so it is in storage mode and adjust the target temperature for the desired grain temperature (usually degrees going into winter). The controller will run the fans at the correct time of the day to change the grain temperature but maintain grain moisture. This eliminates over drying and shrink of the grain and saves on electrical costs. Q: I would like to sell my grain here in the fall - how can I make sure I m setting my controller correctly to have it done quickly? A: The rate of drying is based on the airflow in CFM s / bu. To increase the CFM s, either increase the horsepower of the fans or lower the grain depth in the bin. With the bin properly set up for correct airflow, setting the controller with a wide operational window (suggested settings), the grain will dry at the most efficient (fastest) way. If low temperature burners are installed on the fans, set the controller to operate them automatically making the controller to dry 24 hours a day (as long as temps are above freezing) Q: Should I run the fans when the outside air temperature is below freezing? A: You should NOT freeze the grain in the bin. Freezing the grain can cause condensation issues and waste electricity. If the grain is level and the fines are evenly spread throughout the bin, grain will store at 35 degrees. With the controller reading the grain temps from bottom to top, you can ensure the grain is cooled. The controller can be set to monitor the grain temp with the hot spotting feature and temp controls. If the grain has moisture that requires drying, grain temps need to be above freezing before any moisture can be removed.

9 Frequently Asked Questions During Harvest Continued... Q: What is the difference between EMC and CEMC? A: The Bullseye Controller calculates the EMC and CEMC values to operate the fans correctly. EMC stands for Equilibrium Moisture Content and is what the grain moisture would be equalizing to with the current outside air temperature and relative humidity. CEMC stands for Corrected Equilibrium Moisture Content which re-factors in the fan warming effect or temperature differential from outside air temperature to grain sensor one. CEMC is also used to control a low temperature burner to lower the relative humidity. Q: Who do I contact if I have any questions regarding my Agridry Bullseye Controller? A: Please contact our office with any questions or concerns at AgriDry ( )

10 Currently Available for the Following Devices: Grain Bin Controller CFlow Controller Batch Dryer Controller Stage Batch Dryer Controller All Tem (Using the KTX-Wireless System from Boone) Need a Login? Send an to support@agridryllc.com 1. Your name and phone (the you send the request from will be used) 2. Please include who the account is under (they will be called to verify) 3. The account holder s cell number, City & State 4. If no agreement is on file the account holder will need to sign the agreement **AgriDry will then call the account holder and verify the request and level of access. Why is my controller not updating? 1. The Gateway may not have power. Troubleshooting: Login to AgriDryLink.com and find the Device Status page under Gateway Status. If the status is reporting OFFLINE, check the gateway for power. If the box appears to have power, unplug and replug in the power cord to the gateway to restart. After 10 minutes, click Get Current Reading/Setting on AgriDryLink.com. Contact support if readings do not appear after 15 minutes. 2. Your subscription my be inactive. Troubleshooting: Login to AgriDryLink.com and find the Subscription Status page under Device Status. If the Subscription Plan is reporting NOT ACTIVATED, choose Edit Subscription to the right, enter billing information or simply turn the subscription ON. There is a video on our website to help with this process. Once completed, click Get Current Reading/ Setting on AgriDryLink.com. Contact support if readings do not appear after 15 minutes. 3. Installation may not be complete. Troubleshooting: Login to AgriDryLink.com to see the units that are being shipped. If you do not have an account with AgriDryLink.com, please check your for the ADLink Agreement or Verification of your address. If you do not see either one of these s, please follow the instructions above under Need a Login? and we will help you complete your set-up. Self-Help Videos: Signing the Agreement: For quick controller set-up: check out the videos online about the ADLink Wizard after installation or when storage and weather conditions change.

11

12

13 AgriDry s Pre-Harvest Checklist It is always good to check your harvest equipment before you hit the fields. Be sure to check out your AgriDry equipment as well. Most common issues during harvest can be prevented by completing the check sheet below. If you would like AgriDry to check your equipment for you, contact us at AgriDry and set up a service call. BULLSEYE BIN CONTROLLER: Controller Powers-Up Temperature cables are reading accurate Air Temp / Humidity is accurate Switch Operates Fans When BE is in Manual BE Operates Fans When in Auto (w/grain) SPREADER: No damage to any spreader parts The spreader is still properly hanging All chutes are still at the correct angle The spreader is cleaned out from harvest The leveling band and chutes are completely empty from grain or FM BULLSEYE DRYER CONTROLLER: Controller Powers-Up Moisture sensor is clean Moisture sensor reads with grain on it Dryer sensors are reading ADLINK FOR BULLSEYE: AD Link Modem / Gateway Lights ON Subscription is setup and paid

Mixed Flow GRAIN DRYER PATENT PENDING

Mixed Flow GRAIN DRYER PATENT PENDING Mixed Flow GRAIN DRYER Low Maintenance Cleaning Energy Efficient Vacuum Cooling Simple Single-Conveyor Unloading QuadraTouch Pro Control System VACUUM-COOLING SUKUP EXCLUSIVE Sukup Manufacturing is the

More information

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT OUR PART condition store harvest use or market CHOICES field dry & store natural air dry & store dryer store dryer store natural air

More information

Drying and Cooling Stored Grain and Preserving its Quality

Drying and Cooling Stored Grain and Preserving its Quality Drying and Cooling Stored Grain and Preserving its Quality July 25, 2012 Dr. Greg Brenneman ISU Ag Engineering Specialist Conditions that Lead to Storage Problems Grain that is too wet Grain that is too

More information

Grain Handling, Drying and Storage Management

Grain Handling, Drying and Storage Management Grain Handling, Drying and Storage Management Michael J. Buschermohle Biosystems Engineering and Soil Science Grain Handling, Drying and Storage Management What Affects Grain Quality Grain Handling Grain

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

Minimize Shrink from Grain Drying and Aeration

Minimize Shrink from Grain Drying and Aeration Minimize Shrink from Grain Drying and Aeration Dry grain stored at cooler temperature has the minimal risk of spoilage from mold contamination and can be safely stored for longer periods (6-12 months).

More information

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer Energy Efficient Corn Drying Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer Estimated Corn Field Drying EMC (%) PET (in) Est. Drying (%pt) Month Week Sep 15 4.0-5.0 18 4.5 Oct 16 2.8-3.5

More information

SEED DRYING. Definitions 8/31/2017. Potential mechanisms involved in desiccation tolerance. Phases of Seed Development and Maturation

SEED DRYING. Definitions 8/31/2017. Potential mechanisms involved in desiccation tolerance. Phases of Seed Development and Maturation SEED DEVELOPMENT OF ORTHODOX vs RECALCITRANT (Review article, Farrant et. al., 1993) 8/31/2017 SEED DRYING ACQUISITION OF DESICCATION TOLERANCE IN SEEDS Definitions DESICCATION TOLERANCE: It is generally

More information

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions Agenda Comfort Advantage System Configurations Installing ComfortNet ComfortNet Control Set up Dehumidification and Defrost Settings

More information

Sears Craftsman Support Manual Garage Door Opener Keypad Reset

Sears Craftsman Support Manual Garage Door Opener Keypad Reset Sears Craftsman Support Manual Garage Door Opener Keypad Reset Find error codes for your Craftsman garage door opener at Sears PartsDirect. Learn what to Following the instructions in your owner's manual.

More information

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost Know how. Know now. EC710 Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost Thomas W. Dorn, Extension Educator With prices for all energy sources rising dramatically in recent

More information

IntelliSync Thermostat / Mobile App Frequently Asked Questions

IntelliSync Thermostat / Mobile App Frequently Asked Questions IntelliSync Thermostat / Mobile App Frequently Asked Questions This FAQ page addresses the most common questions on Deriva IntelliSync. Why bother setting a heating and cooling schedule? What is ENERGY

More information

V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers)

V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers) QuadraTouch Pro Software Update Change Log Official Release vs. Beta Release (How to tell): Tools -> System Tools -> System Information and look for Official Release or Beta Release in the bottom right

More information

SQ SERIES DRYERS GRAIN MANAGEMENT SYSTEMS

SQ SERIES DRYERS GRAIN MANAGEMENT SYSTEMS SQ SERIES DRYERS SQ STORAGE HANDLING CONDITIONING STRUCTURES GRAIN MANAGEMENT SYSTEMS SQ CHOICE OF DRYING MODES FULL HEAT CONTINUOUS FLOW DRYERS SQ D Series Full Heat Single Zone FULL HEAT CONTINUOUS FLOW

More information

CC196 Guide for Batch-Drying in a Bin

CC196 Guide for Batch-Drying in a Bin University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Historical Materials from University of Nebraska- Lincoln Extension Extension April 2014 CC196 Guide for Batch-Drying in

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Managing your Dryer And Shrink NGFA / Grain Journal Conference Aug 1 - Aug 2, Bob Marlow, The Andersons, Inc

Managing your Dryer And Shrink NGFA / Grain Journal Conference Aug 1 - Aug 2, Bob Marlow, The Andersons, Inc Managing your Dryer And Shrink NGFA / Grain Journal Conference Aug 1 - Aug 2, 2012 Bob Marlow, The Andersons, Inc Dryer Performance What year was your dryer built? When you talk performance, do you talk

More information

Grain Dryer Exhaust Air Recycling System

Grain Dryer Exhaust Air Recycling System Grain Dryer Exhaust Air Recycling System For Farm Fans Inc. AB-Series Grain Dryers By: Tony Wagner 1 Grain Drying Introduction Why dry grain? Must be dried before storage to prevent spoilage Eliminates

More information

CC197 Guide to In-Storage Drying with Supplemental Heat

CC197 Guide to In-Storage Drying with Supplemental Heat University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Historical Materials from University of Nebraska- Lincoln Extension Extension April 2014 CC197 Guide to In-Storage Drying

More information

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on. DRYER OPERATION - START-UP INITIAL SETUP PARAMETERS Turn the control power switch to on. When the Boot Screen appears touch the START DRYER button. The computer will run a quick check of the system network

More information

OPI-integris Advantages

OPI-integris Advantages Agenda OPI-integris Advantages OPI-integris System Solutions IntegrisPro Advanced Grain Management System IntegrisPro System Applications Advanced Grain Management OPI-integris Service Enhancements OPI-integris

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Dryer Master DM510 Users Guide

Dryer Master DM510 Users Guide Dryer Master DM510 Users Guide Dryer Moisture Systems Inc. 115 Ardelt Ave. Kitchener, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com Reminder

More information

Before you install ProSeries Express Edition software for network use

Before you install ProSeries Express Edition software for network use Before you install ProSeries Express Edition software for network use The following pages describe system requirements and other information you need to know before installing ProSeries Express Edition

More information

QuadraTouch Pro Software Manual Dryer Control System

QuadraTouch Pro Software Manual Dryer Control System QuadraTouch Pro Software Manual Dryer Control System Software is constantly changing. Make sure you are up to date with Sukup s newest software. New software and manuals are available for download at:

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Water Hero P-100 Thank you for purchasing the Water Hero P-100, which offers whole-building leak detection and water conservation monitoring. This box contains: Main Controller

More information

Tower Dryers U Bu/Hr. QuadraTouch Controls Industrial Grade Components

Tower Dryers U Bu/Hr. QuadraTouch Controls Industrial Grade Components Tower Dryers U41 1000-7000 Bu/Hr. QuadraTouch Controls Industrial Grade Components ADVANTAGES 1 ROTARY SENSORS for choke fill or demand fill are standard. STAINLESS STEEL outer screens, nuts, and bolts

More information

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on. DRYER OPERATION - START-UP INITIAL SETUP PARAMETERS Turn the control power switch to on. When the Boot Screen appears touch the START DRYER button. The computer will run a quick check of the system network

More information

Grain Dryer Efficiency. Presented by: Steven Morreim, President QED Dryer Sales & Mfg. Inc th Street Rockford, IL 61104

Grain Dryer Efficiency. Presented by: Steven Morreim, President QED Dryer Sales & Mfg. Inc th Street Rockford, IL 61104 Grain Dryer Efficiency Presented by: Steven Morreim, President QED Dryer Sales & Mfg. Inc. 2401 11 th Street Rockford, IL 61104 Electric, Gas, & Dryer Design Fan design and motor selection for highest

More information

Grain and Soybean Drying on Georgia Farms

Grain and Soybean Drying on Georgia Farms Grain and Soybean Drying on Georgia Farms Table of Contents Principles of Grain Drying... 3 Drying Methods... 3 Moisture Levels for Safe Storage... 4 Equilibrium Moisture Content... 5 Bin Batch Drying...

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL CTRH SERIES 460 Southport Commerce Blvd. Spartanburg SC 29306 Phone: 864-574-6004 Fax: 864-574-6005 CTRH-4 Congratulations! You have just purchased the finest commercial

More information

Competitor Series Dryers

Competitor Series Dryers Cost Efficient, Competitively Priced, Completely GSI. Competitor Series Dryers "Your Complete Systems Manufacturer." THE COMPETITIVE EDGE GSI Competitor 100 Series grain dryers offer all the latest technological

More information

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors Overview 2 This procedure shows how to replace VT8000 Room Controllers already installed, as

More information

Water Hero P-100. P-100 Components:

Water Hero P-100. P-100 Components: Water Hero P-100 Thank you for purchasing the Water Hero P-100. The P-100 offers wholebuilding leak detection, mitigation, and water usage monitoring. P-100 Components: Main Controller Water Meter, Sensor

More information

Estimated Corn Field Drying

Estimated Corn Field Drying October 7, 2014 Corn Drying and Storage 2014 Kenneth Hellevang, Ph.D., PE, Extension Agricultural Engineer, Professor NDSU Extension Service, Ag & Biosystems Engineering Department Field Drying Standing

More information

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Personal Reference Guide Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Welcome to your new Brighten ithermostat

More information

The following table summarizes information from various sources on corn development.

The following table summarizes information from various sources on corn development. October 7, 2009 2009 Post-Harvest Tips for Later Maturing Corn Ken Hellevang, Ph.D., PE, Extension Engineer, Professor NDSU Extension Service, Ag & Biosystems Engineering Department Corn Maturity Progression

More information

9 - On Farm Storage and Drying

9 - On Farm Storage and Drying 9 - On Farm Storage and Drying Dennis R. Gardisser A given volume of air has the capability of holding a given amount of moisture. The amount of moisture that air can hold will depend on the quality. One

More information

HERMS (Heat Exchanger Recirculating Mash System) Controller

HERMS (Heat Exchanger Recirculating Mash System) Controller HERMS (Heat Exchanger Recirculating Mash System) Controller Your new HERMS controller Thanks for buying your controller from us!!! Your controller is based on two MYPIN TA4 series PID controllers. Unlike

More information

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website General/Operational Troubleshooting Guide I have an Error Code: E0 (Thermostat

More information

Aerating Grain in Storage

Aerating Grain in Storage Aerating Grain in Storage Contents Moisture Movement in Metal Bins... 3 Air Flow Requirements... 3 Direction of Air Flow... 4 Air Distribution Methods... 5 Grain Pressure on Ducts... 6 Fan Operation...

More information

INSTALLATION AND INSTRUCTION MANUAL FOR BAC AERATION CONTROLLER

INSTALLATION AND INSTRUCTION MANUAL FOR BAC AERATION CONTROLLER INSTALLATION AND INSTRUCTION MANUAL FOR BAC AERATION CONTROLLER SPECIAL NOTE BOONE AERATION &ENVIRONMENTAL 1773-219TH LANE - P.O. BOX 369 READ THIS ENTIRE BOOKLET BOONE, IOWA 50036 USA BEFORE PROCEEDING

More information

Installing ProSeries software for stand-alone use

Installing ProSeries software for stand-alone use Welcome to ProSeries tax software For information about this topic... Look here... Getting ready Page 1 Installing ProSeries software for stand-alone use Page 1 Setting up the ProSeries program Page 3

More information

YOU KEEP HARVESTING, WE LL KEEP DRYING. Counter-Flow GRAIN DRYING SPECIALISTS

YOU KEEP HARVESTING, WE LL KEEP DRYING. Counter-Flow GRAIN DRYING SPECIALISTS YOU KEEP HARVESTING, WE LL KEEP DRYING. Counter-Flow GRAIN DRYING SPECIALISTS A history of grain handling & drying innovation Shivvers has been the recognized leader in Counter-Flow grain drying technology

More information

Competitor Series Dryers

Competitor Series Dryers Cost Efficient, Competitively Priced, Completely GSI. Competitor Series Dryers "Your Complete Systems Manufacturer." THE COMPETITIVE EDGE GSI Competitor 100 Series grain dryers offer all the latest technological

More information

EasyDry. Grain Drying Systems

EasyDry. Grain Drying Systems EasyDry Grain Drying Systems Grain Drying & Storage System Raise your standards high, with EasyDry. EasyDry enhances your on-farm grain storage system efficiency and overall grain quaility. EasyDry from

More information

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.

More information

Aerating Farm -Stored Grain

Aerating Farm -Stored Grain T Aerating Farm -Stored Grain oo MUCH M;OISTURE MIGRATION in stored grain may cause heating and molding - then spoilage and caking - in the top several inches. This can happen even in grain that has been

More information

Product Guide. What is 5LINX Security Systems? Selling Security Systems: Ask the customer. Features and Benefits:

Product Guide. What is 5LINX Security Systems? Selling Security Systems: Ask the customer. Features and Benefits: What is 5LINX Security Systems? Product Guide 5LINX Security Systems provided by Protect America Inc. specializes in Security Systems for your home or business. Protect America is one of the fastest growing

More information

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov 3005925_2018-02-05.fm EXcon zone control Control for up to 4 individual zones EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk OJ-Air2

More information

CC196 Revised with no date Guide for Batch- Drying in a bin

CC196 Revised with no date Guide for Batch- Drying in a bin University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Historical Materials from University of Nebraska- Lincoln Extension Extension April 2014 CC196 Revised with no date Guide

More information

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION Ultra Clean Installation and Operation Manual LAMBTON CONVEYOR LIMITED ONE SOURCE 1 Contents Warranty... 4 Section 1. Safety... 5 Section 2. Decals... 8 Section 3. Product Information... 9 Ultra Clean

More information

Vision for Portable Dryers

Vision for Portable Dryers Vision for Portable Dryers Operation Manual PNEG-1739 Date: 06-21-10 PNEG-1739 2 PNEG-1739 Vision for Portable Dryers Table of Contents Contents Chapter 1 Safety...5 Safety Guidelines... 5 Dryer Operation...

More information

User Guide. Portable banknote counter AB300

User Guide. Portable banknote counter AB300 User Guide Portable banknote counter AB300 Thank you for purchasing this AccuBANKER product. We recommend reading all information in the user guide to become familiar with this product. AccuBANKER and

More information

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone

More information

Step 1 - Install ProSeries Basic software

Step 1 - Install ProSeries Basic software Welcome to ProSeries Basic tax software Please follow steps 1 through 3 in this guide: For this step... Look here... Getting ready Page 1 Step 1 - Install ProSeries Basic softwarepage 1 Step 2 - Set up

More information

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

Portable Dehumidifier

Portable Dehumidifier Portable Dehumidifier OPERATING INSTRUCTIONS HMT-D30-A Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A HMT-D45E-A HMT-D70E-A 3058080 V.161115 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable

More information

Dryer Master DM510 Commissioning Guide

Dryer Master DM510 Commissioning Guide COMMISSIONING GUIDE Dryer Master DM510 Dryer Moisture Systems Inc. 640 Superior Drive Waterloo, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com

More information

(c) 1520 St. Olaf Ave. Northfield, MN 55057

(c) 1520 St. Olaf Ave. Northfield, MN 55057 Milkweed Germination and Planting Protocol Notes: Each school will receive 300 seeds total: 100 from their home site, or ecotype, and 50 from each for four other ecotypes. The seeds will be a mix of seeds

More information

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Rev C May GE Interlogix.   Part No: R. CareGard. User Guide g 466-1936 Rev C May 2003 GE Interlogix www.ge-interlogix.com Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by

More information

Aeration vs NAD vs NAD+heating vs Heated Air Drying

Aeration vs NAD vs NAD+heating vs Heated Air Drying Aeration vs NAD vs NAD+heating vs Heated Air Drying SEPTEMBER, 2018 @JoyAgnew3 @PAMI_Machinery General grain drying principles Effect of adding heat on air s capacity to dry grain Sources of heat, sizing

More information

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference Dehumidifier/Dryer Model: EDV-4000 Please read the instruction manual before operating. Keep in a safe place for future reference IMPORTANT SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE

More information

Daikin ENVi Thermostat installation overview

Daikin ENVi Thermostat installation overview Daikin ENVi Thermostat installation overview RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Presenter s Name Presenter s Title Daikin ENVi system overview (web based thermostat) Slide 2 Daikin ENVi System Overview

More information

P08033W Air Dryer Cycling Module User s Guide

P08033W Air Dryer Cycling Module User s Guide P08033W Air Dryer Cycling Module User s Guide 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P08033W Air Dryer Cycling Module! We here at PUREGAS are very proud of our

More information

AirTMCordless SWITCH CORDLESS, 2-IN-1, STICK AND HANDHELD LET S GET STARTED. H85-AC21-B H85-AC21-P H85-AC21-BB

AirTMCordless SWITCH CORDLESS, 2-IN-1, STICK AND HANDHELD LET S GET STARTED. H85-AC21-B H85-AC21-P H85-AC21-BB AirTMCordless SWITCH CORDLESS, 2-IN-1, STICK AND HANDHELD LET S GET STARTED. H85-AC21-B H85-AC21-P H85-AC21-BB Let s talk safety Basic safety precautions This vacuum cleaner is intended for household use

More information

S82967 FAQS CONTENTS

S82967 FAQS CONTENTS S82967 FAQS We are weather enthusiasts like you and know proper running equipment is important. These FAQS provide valuable information on setup, positioning, and troubleshooting your station. We recommend

More information

TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR

TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR Version: 1-26-2011 ACTIVITY / ALARM MONITOR IN SENTINEL Activity / Alarm Monitor Overview The Activity/Alarm Monitor screen combines the separate

More information

Conical Fermenter. Instructions

Conical Fermenter. Instructions Conical Fermenter Instructions What s in the Box?: 01. AIRLOCK Rubber Bung Fermenter lid Fermenter Body CONTENTS WHAT S IN THE BOX...P1 ANATOMY/SCHEMATICS...P2 FERMENTING WITH THE STANDARD FERMENTER...P.5

More information

Part of the Crop Monitoring and Automatic control range. The most advanced automatic fan control and crop monitoring system available

Part of the Crop Monitoring and Automatic control range. The most advanced automatic fan control and crop monitoring system available Martin Lishman Barn Owl Part of the Crop Monitoring and Automatic control range The most advanced automatic fan control and crop monitoring system available and Remote Monitoring and Automatic Fan Control

More information

Wiring Diagram for Nuheat SIGNATURE, HOME & Element Thermostats

Wiring Diagram for Nuheat SIGNATURE, HOME & Element Thermostats Wiring Diagram for Nuheat SIGNATURE, HOME & Element Thermostats Line (Black) Line White (120V) or Red (240V) Nuheat White (120V) or Red (240V) Nuheat (Black) Terminals for the floor sensor are located

More information

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL π H-6369, H-6370 DEHUMIDIFIER 1-800-295-5510 uline.com GENERAL INFORMATION RECOMMENDED HUMIDITY LEVELS Spring/Summer: 35% - 50% Fall/Winter: 35% - 40% WARM AIR EXHAUST IS NORMAL During operation your dehumidifier

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

Continuous Mixed-Flow Under FaN Grain Dryers

Continuous Mixed-Flow Under FaN Grain Dryers Continuous Mixed-Flow Under FaN Grain Dryers We believe the quality of your grain should reflect the hard work you put into it. There s nothing standard about Superior. At Superior, we believe the quality

More information

Sensor Control Panel

Sensor Control Panel USER S MANUAL PU SENS 01 Sensor Control Panel V55-6EN-03(SENS).indd 1 18.08.2015 10:37:16 2 PU SENS 01 CONTENTS Safety Requirements 2 Main Technical Data 3 Control Panel Mounting 3 Control Panel Operation

More information

Version 2.2. Radiator Valve (TRV) Model No. LW922. Instruction Manual. Professional Series.

Version 2.2. Radiator Valve (TRV) Model No. LW922. Instruction Manual. Professional Series. Version 2.2 Radiator Valve (TRV) Model No. LW922 Instruction Manual Professional Series www.lightwaverf.house EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham

More information

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System Technical Bulletin AD-1272 Code No. LIT-12012477 Issued December 2017 Refer to the QuickLIT website for the most up-to-date version of

More information

Model: PC600. Batch: PR3496. POWER:1000W AC V, 50/60Hz For your safety, always read the instruction book carefully before using.

Model: PC600. Batch: PR3496. POWER:1000W AC V, 50/60Hz For your safety, always read the instruction book carefully before using. Model: PC600 Batch: PR3496 POWER:1000W AC220-240V, 50/60Hz For your safety, always read the instruction book carefully before using. Introduction-----------------------------------------------------------------------------------------------

More information

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide IndigoVision GAI-Tronics Integration Module Administrator's Guide GAI-Tronics Integration Module THIS MANUAL WAS CREATED ON 10 APRIL 2013. DOCUMENT ID: IU-IM-MAN019-1 Legal Considerations LAWS THAT CAN

More information

In Home Device Reference Guide. Brought to you by

In Home Device Reference Guide. Brought to you by Device Reference Guide Brought to you by & The following were provided to you at the time of installation: Wireless CT Sensor Installed near your Xcel Energy meter Sends whole home electricity usage data

More information

RenewableEnergy. A Guide to Prepare for a Grain Dryer Energy Audit. Introduction. Fueling and Feeding America Through Renewable Resources

RenewableEnergy. A Guide to Prepare for a Grain Dryer Energy Audit. Introduction. Fueling and Feeding America Through Renewable Resources RE-11-W RenewableEnergy A Guide to Prepare for a Grain Dryer Energy Audit Klein E. Ileleji, Chad Martin, and Gabriel De Melo Lima Miranda Department of Agricultural and Biological Engineering, Purdue University

More information

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Utopian Split A/C. Thank you for purchasing this quality Split A/C system! Utopian Split A/C Thank you for purchasing this quality Split A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any operation

More information

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.

More information

INTELLIGENT, HEALTHFUL LIVING

INTELLIGENT, HEALTHFUL LIVING Lee Household Flour Mill MODEL S-700 INTELLIGENT, HEALTHFUL LIVING 1 M150701302 Rev G T En an w Pa Im 3 B H Sp W R C Tr D C 2 Lee Household Flour Mill MODEL S-700 Thank you for purchasing your Lee Household

More information

REBATE. Ductless Mini-Split Heat Pump

REBATE. Ductless Mini-Split Heat Pump Ductless REBATE COOL SMART is offering residential customers of program sponsors up to a $500 rebate for purchasing and installing a ductless mini-split heat pump that meets the program s energy efficiency

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

Contents. Identifying your nbn supplied equipment. Installation. Plugging devices into your nbn connection box

Contents. Identifying your nbn supplied equipment. Installation. Plugging devices into your nbn connection box nbn User guide Contents Identifying your nbn supplied equipment 4 Installation 5 Plugging devices into your nbn connection box 6 Indicator lights on your nbn connection box 7 Maintaining your nbn supplied

More information

Dryer Master DM510 Users Guide

Dryer Master DM510 Users Guide DRYER MASTER DM510 --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More information

ITAS / ITAS-EXT / ITLS / ITLS-EXT

ITAS / ITAS-EXT / ITLS / ITLS-EXT Chromalox Heat Trace Control Panel Instruction Manual and Set-up Guide A Complete Heat Trace Control Solution ITAS / ITAS-EXT / ITLS / ITLS-EXT ITAS ITAS-EXT ITLS ITLS-EXT Ambient Sensing Control Panel

More information

CALDWELL DRYER OPERATION MANUAL. P/N Rev 0

CALDWELL DRYER OPERATION MANUAL. P/N Rev 0 CALDWELL DRYER OPERATION MANUAL P/N 095256 Rev 0 C H I E F I N D U S T R I E S, I N C. A G R I / I N D U S T R I A L D I V I S I O N Installation Manual WARNING: If the information in this manual is not

More information

USER S GUIDE. AXIS Cross Line Detection

USER S GUIDE. AXIS Cross Line Detection USER S GUIDE AXIS Cross Line Detection User s Guide Rev. 1.00 Copyright Axis Communications AB, 2009 November 2009 Part no. 36687 AXIS Cross Line Detection AXIS Cross Line Detection is a trip-wire application

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS User Manual INDEX IMPORTANT SAFETY INSTRUCTIONS... 1 FEATURES... 2 SPECIFICATIONS...2 PRODUCT DESCRIPTION... 3 THE CONTROL PANEL... 4 UNIT SETUP... 5 TO OPERATE SAFELY... 5 OPERATING INSTRUCTIONS... 6-10

More information

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Thermostat INSTALLATION GUIDE Models: 1F86U-42WF, UP500W Version: October 2017 2017 Emerson Electric Co. All rights reserved. CONTENTS Installation guide Downloading the Sensi app 3 Creating

More information

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

EFFICIENT GRAIN DRYING + STORAGE TOPDRY GRAIN DRYER PROVEN & DEPENDABLE

EFFICIENT GRAIN DRYING + STORAGE TOPDRY GRAIN DRYER PROVEN & DEPENDABLE EFFICIENT GRAIN DRYING + STORAGE TOPDRY GRAIN DRYER PROVEN & DEPENDABLE WWW.GRAINSYSTEMS.COM PROVEN & DEPENDABLE The demands of farming are never-ending. The risks are high. And, at harvest, every second

More information

Security + Automation Made Easy QUICK START GUIDE

Security + Automation Made Easy QUICK START GUIDE Security + Automation Made Easy QUICK START GUIDE To set up your yard sign, attach the sign to the post with the two provided screws. Then slide the top and bottom pieces of the post into the gray coupler.

More information

Manual Vane Anemometer PCE-VA 20

Manual Vane Anemometer PCE-VA 20 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules For Obvius A89DC-08 sensor modules Introduction Large roof and ground arrays connect the panels into stings that are merged together in combiner boxes. Each string will typically consist of 10-15 panels

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information