INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

Size: px
Start display at page:

Download "INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM"

Transcription

1 Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS 62

2 Integrated Communications Control with Mitsubishi's Unique Transmission Network() Operation Start Stop Operation mode Temperature setting Permit Prohibit direction Fan speed Air flow direction ONOFF Model No. of units controllable (Groups (G) units) Error flashing Local remote Simple Wireless Remote remote remote PAR-21MAA ONOFF remote Group remote System remote PAC-SF44SRA System Schedule timer Centralized PAR-F27MEA PAC-SEYT51CRA PAR-FA32MA PAR-FL32MA PAC-YT40ANRA PAC-SC30GRA PAC-YT34STA G-50A GB-50A TG-2000A 50G50units 50G50units 1G16units 1G16units 1G16units 1G16units G16units G50U 2000G2000units G-50A browser GB-50A browser *4 *4 *4 63 Monitoring Scheduling Recording Others Control and management Operation Monitoring Error content Filter sign Operating hour Operation mode Set temperature Indoor temperature (intake) Permit Prohibit Fan speed Air flow direction Weekly Annual (Designated day setting) One day Times of stops Starts per day Times of stops Starts per week Auto off timer Minimum setting unit (minutes) Error history Daily Monthly reports Electricity charges Set temperature range limit Auto lock Ventilation (group interlocked) Group setting Block setting Revision of electricity charges Ventilation (group interlocked) Ventilation (group interlocked) Start Stop Fan speed Ventilation mode Status Fan speed Ventilation mode * *5 *5 * *5 : Each group Batched : Each group : Block (City Multi indoor unit only) : Batched handling (for maintenance) : Batched only : Not available : Not used : G-50A license registration possible. *1: For group operation, cross-over wring is required between indoor unit. : Installation possible at Initial setting tool. *3: Interlock setting from local remote. *4: From schedule setting *5: When PAC-YT32PTA is connected *3 * 5 * 5 48 * *

3 Building Air conditioning HAND-HELD MA PAR-21MAA Example of system configuration Non-polarized 2-wire MA remote Non-polarized 2-wire MA remote High-quality pure-white color body Dot liquid-crystal display is applied Symbols, Japanese, Chinese, English, Germany,Spanish, Russian, Italian, French display can be selected freely. TM Connectable to all CITYMULTI indoor unit, and automatically adjust its function with the indoor unit connected Limiting temperature setting range is possible Help to avoid over-cooling or over-heating. Save energy. Auto-stop timer is available Help to avoid forgetting to stop the air conditioner. Weekly scheduler is available ONOFFTemperature setting 8 times per day, 1 week scheduling. Grouping via cross-over wire directly Usable as the local remote for system (MELANS) Combining ME remote andor LOSSNAY remote in a group is not possible. LCD temperature setting and display in 1 C 1 F unit. ME PAR-F27MEA Example of system configuration ME remote ME remote Easy to read, easy to operate icon display Temperature selection Room air temperature display Outlet angle display Displays the angle of blowing between 20 and 70. (Only for cassette model PL and PK. Ceiling mounted models display the air volume ratio.) Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occur, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. Standardized remote s for all indoor units All wiring is simply done with non-polarized two-wire signal lines Room thermometer is built into the remote Daily timer Repeated ON OFF timer every day. Auto OFF timer 0:30, 1:00, 1:30, 2:00...4:00 one touch timer. Function lock All functions or all functions except ON OFF can be selected. Limit setting of room temperature. 64

4 Building Air conditioning HAND-HELD SIMPLE MA PAC-YT51CRA PAC-YT51CRA To simplify operation of the system, the range of controls has been limited to STARTSTOP, room temperature and fan speed The only wiring required is cross-over wiring based on two-wire signal lines Room temperature sensors are built-in. The indoor unit can be replaced with body thermostats Easy to read, easy to operate icon display LCD temperature setting and display in 1 C 1 F unit. Can operate all types of indoor units Standardized remote s for all indoor units *Since this system has no operation mode switching, test operation, selfdiagnosis or interlock setting functions, it should always be used in conjunction with the PAR-21MAA or other centralized. *Combining ME remote andor LOSSNAY remote in a group is not possible. WIRELESS PAR-FL32MA PAR-FA32MA Wireless construction supports multi - systems in buildings. No need to configure addresses for group operation. Lit LED keeps you informed of operation - blinking even gives you the error code via the number of blinks. Can be used with the MA remote. *When used in group configurations, wiring between indoor units is required. *Combining ME remote andor LOSSNAY remote in a group is not possible. LCD temperature setting and display in 1 C 1 F unit. PAR-FL32MA PAR-FA32MA 65

5 UP UP POWER SUPPLY UNIT MODEL PAC-SC50KUA POWER RATING WEIGHT 2.11kg SERIAL No. MITSUBISHI ELECTRIC CORPORATION POWER SUPPLY UNIT MODEL PAC-SC50KUA POWER RATING WEIGHT 2.11kg SERIAL No. MITSUBISHI ELECTRIC CORPORATION Building Air conditioning CENTRAL CONTROLLER G-50AGB-50A Up to 50 units of packaged air conditioners can freely be monitored and operated! Furthermore, it has enabled the Monitoring and Operation Via a Web Browser on a Personal Computer connected to it using a LAN or telephone line! First in the industry With Web Server Functions! G-50A (with display) GB-50A Simple and Flexible This new generation is suitable for small to large systems with simple to complex functions available. Web Browser Enables monitoring and operation of air conditioning units using a PC with Microsoft Internet Explorer. Remote Access Allows users to remotely monitor and operate the air conditioning units using a PC connected to a telephone line. Auto Alarm In the case of any malfunction, necessary information will be sent to a mobile phone andor personal computer by . Easy to Upgrade Various new functions will be introduced gradually and can easily be down loaded into any existing G-50AGB-50A. Example: Energy Monitoring Demand Control Annual Schedule Example of display icons (air conditioner icons) Operation In timer operation Stop Lossnay on Occurrence of abnormality Under energy-saving control Operation Occurrence of a filter sign System Structure Remote monitoring via a Web browser Web browser G-50A City Multi outdoor unit Public telephone line Provider Router Ethernet Power supply unit PAC-SC50KUA City Multi Provider GB-50A City Multi outdoor unit Power supply unit PAC-SC50KUA City Multi * Microsoft is a trademark or trademark of Microsoft corporation. 66

6 UP Building Air conditioning GROUP PAC-SC30GRA Up to 8 groups can be operated (maximum of 16 units). Just by pressing switches, groups can be started and stopped individually, or all groups can be started and stopped as a batch. Detailed settings and operations can also be made for each individual group. All the wiring is simply done with non-polarized two wire signal lines. The connection is the same as the connection to the master system. It supports operation of groups that can extend beyond one refrigerant system. Furthermore, it is possible to drive interlocked systems that use ventilator equipment or drive ventilator equipment in a stand-alone situation. *With the group remote, you cannot control groups that only contain the LOSSNAY remote. *It is impossible to use the group remote to control K control units. *When connecting to signal cables for central control, it must use a power supply unit for the signal cables. System example Connect to the centralized transmission line Group remote Power supply unit MA RC MA RC RC:Remote Controller Connect to the indooroutdoor transmission line 67 RC:Remote Controller Group remote MA RC MA RC

7 UP Building Air conditioning SYSTEM PAC-SF44SRA 50 groups50 units of air conditioners can be controlled Up to 50 groups50 units of air conditioners can be operated with one remote. A general-purpose interface is available for control, so general devices can also be turned ON and OFF. Operation status displayed on easy-to-read LCD The group currently operating can be seen at a glance with the operation status display for each group. Independent LOSSNAY operation is possible LOSSNAY units can be grouped the same as the Central remote and ONOFF remote. "Automatic ventilation", "Normal ventilation" and "Ventilation with heat exchanger" can be switched from the system. Simple remote limited to basic operations. The only operations required for the air conditioner are "ONOFF", "Operation mode changeover", "Temperature setting" and "Prohibit operation by local remote ", so anyone can easilyoperate the unit. Using collective control from the system remote, operation mode settings using the local remote s can be prohibited. (Operation mode limit function) Schedule operation is available Groups of air conditioners are available for operation at a set schedule using the Schedule timer (PAC-YT34STA). System example System remote Power supply unit MA RC MA RC LOSSNAY PZ-52SF LOSSNAY LOSSNAY PZ-52SF RC:Remote Controller 68

8 UP Building Air conditioning Schedule timer PAC-YT34STA The weekly schedule of up to 50 groups50 units can be controlled with one schedule timer. General-purpose devices can also be turned ON and OFF by connecting a general-purpose interface. The weekly schedule of up to ten patterns (no setting + nine patterns) is available for setting. "ONOFF", "Operation Prohibit", "COOLHEAT" and "Set Temperature" can be scheduled with up to 16 settings in one pattern. It can be connected to the center control transmission line or to the indooroutdoor transmission line without the power supply unit (PAC-SC50KUA). It is nonpolar 2-wire. It can be interlocked with a building management system using the external inputoutput managing function. An error unit address and error code appear on the display. (*) Use in combination with other system s. System example System remote Power supply unit ME RC LOSSNAY Schedule timer MA RC Simple ME RC RC:Remote Controller 69

9 Building Air conditioning ONOFF remote PAC-YT40ANRA 16 groups50 units can be controlled Up to 16 groups50 units can be operated with one ONOFF remote. A general-purpose interface is available for control, so general devices can also be turned ON and OFF. Just press a switch to start. All of the units can be started and stopped by pressing the main switch, and each unit in the group can be started and stopped with individual switches. A general-purpose interface is available for control, so general devices can also be turned ON and OFF. LED flashing during failure. If any error should occur in the air conditioner, its details can be confirmed easily with the flashing LED. The LED also indicates whether each group is running or stopped. Interlock operation with external system possible. It can be flexibly interlocked with a card reader, fire alarm system or building management system, etc., using the incorporated external inputoutput function. Flexible group setting. The groups can be easily configured, so the group pattern can be freely set according to the layout. The ONOFF remote can be connected at the indooroutdoor transmission line without the power supply unit. System example LOSSNAY ONOFF remote PAR-F27MEA PZ-52SF PAR-21MAA RC:Remote Controller PAC-YT51CRA 70

10 UP POWER SUPPLY UNIT MODEL PAC-SC50KUA POWER RATING WEIGHT 2.11kg SERIAL No. MITSUBISHI ELECTRIC CORPORATION Building Air conditioning Integrated centralized control software TG-2000A (1) Example of Basic System Configuration. Charge license Web monitor license Input G-50A 12VDC Single-phase V Single-phase V Schedule license Uninterruptive power supply (UPS) Power supply unit PAC-SC50KUA 3-phase V (3-wire) RS-232C RS-485 Indoor unit system watt-hour meter Outdoor unit system watt-hour meter Converter Central personal computer TG-2000A Indoor unit watt-hour meter Compatible with TG-2000A Ver and higher * The electric amount count software or separately procured parts must be used with the designated PLC. Uninterruptible power supply (UPS) power source Indoor unit system watt-hour meter Indoor unit watt-hour meter Outdoor unit system watt-hour meter PLC (with electric amount count software) Central control personal computer TG-2000A Integrated centralized control software installation Integrated centralized control software installation 71 Main features of TG-2000A The TG-2000A can realize the following functions using the G-50AGB-50A option (license). * Operationmonitor * Annualweekly schedule * Charge * Energy saving *1 * Peak cut *1 *1: Compatible with TG-2000A Ver and higher, G-50A Ver or later. 1 Up to 2000 indoor units (40 G-50AGB-50A units) can be operated and monitored simultaneously. 2 The air-conditioner layout can be displayed on the screen, making control and operation easier. 3 The annual and weekly schedules can be set. Two schedules, such as the summer master and winter master, can be saved in the weekly schedule. 4 Air-conditioning charges can be calculated based on the multiple air-conditioner usage results. The power apportionment percentage data and apportioned power rate can be calculated for each indoor unit using the power apportionment function, and can be output as a CSV format file. * Power apportionment charging is not possible with the old model, A control or K control. Charging without WHM : The user manually inputs the power rate to calculate the air-conditioning charges. (Using a tool) RS-485 WHM charging : The RS-485 WHM value is automatically tabulated to calculate the air-conditioning charges. PLC + pulse WHM charging : The pulse output WHM value is automatically tabulated by the PLC to calculate the air-conditioning charges. 5 Energy saving operation is possible using the "ONOFF", "set temperature change", "fan operation changeover" and "performance save operation (60% to 90%)" functions. Energy saving operation matching the amount of power in use is possible by using the PLC's electric amount count software. 6 Night set-back operation is possible with schedule settings. *1*4 7 General equipment can be operated and monitored. 8 General equipment can be schedule-controlled when using PAC-YG21CDA with PLC. For details of PLC refer to Installation Manual of PAC-YG21CDA. *3 *1: Compatible with TG-2000A Ver and higher, G-50A Ver and higher. : Compatible with TG-2000A Ver and higher, G-50A Ver and higher. *3: Compatible with TG-2000A Ver and higher, G-50A Ver and higher. *4: With Night Set-Back function,the CITY MULTI system can run at heating mode with target temperature set to 54 F12 C under schedule control. This function can protect the room from dropping down to extremely low temperature at mid-night.

11 Building Air conditioning LONWORKS (LMAP02) CITY MULTI TM can easily combine into a Building Management System (BMS) via the LonWorks TM and adapter LMAP03-U. LonWorks TM is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTI TM is therefore compatible with large-scaled BMS management via LonWorks TM. One LM ADAPTER unit can connect up to 50 Groups50 indoor units. Using a single LONWORKS adapter (LM ADAPTER), you can connect up to a maximum of 50 indoor units. Operation Monitor Item Request OnOff Request Mode Setpoint from network (Both cool and heat) Request Fanspeed Request Local Prohibit OnOff Request Local Prohibit mode Request Local Prohibit SetPoint Request All Off OnOff run state Mode state Setpoint state (both cool and heat) FanSpeed state Thermo OnOff state Temperature state of indoor Alarm state Local Prohibit OnOff state Local Prohibit mode state Local Prohibit SetPoint state LMAP LMAP 02 Protocol converter between LON WORKS and LON WORKS LMAP CITY MULTI System Example of System Configuration System design made simple through integration of various devices into a total control configuration V 60Hz Outdoor unit CITY MULTI Outdoor unit LON WORKS (78kdps) LMAP Indoor units Max. 50 indoor units Indoor units Indoor units Indoor units Indoor units Center control device Lighting Security Remote Remote Remote Remote Remote LON WORKS The building management system is connected to the CITY MULTI air conditioning system using LON WORKS, which is widely used on field networks, allowing for an open network and savings in construction to face. LON, LON WORKS and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. 72

12 UP Building Air conditioning BACnet TM interface(pac-yg31cda) MITSUBISHI ELECTRIC's CITYMULTI can be easily connect to the building management system through BACnet. BACnet is the appropriate transmission method and used in many of the backbone networks and also it is easy to combine with other equipment corresponding to BACnet. One BACnet interface software manages up to 500 Groups500 Indoor units. (10 G-50AGB-50A units). (1) Example of Basic System Configuration. Central monitor BMS TM BACnet LAN G-50A WHM WHM TM BACnet interface software PAC-YG31CDA PAC-SC50KUA Power supply unit G-50A Web Browser (Optional) TG-2000A (Optional) 73 Operation Monitor Item OnOff (state) Operation mode (state) Fan Speed (state) Air direction (state) Room Temp. Filter Signal Alam signal Error Code Communication State OnOff (setup) Operation mode (setup) Fan Speed (setup) Air direction (setup) Set Temp. Filter Signal Prohibition of local operation (OnOff) Prohibition of local operation (Mode) Prohibition of local operation (filter reset) Prohibition of local operation (Set temp.) System Forced Off

The importance of control

The importance of control The importance of control Individual Centralized The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric

More information

AIR CONDITIONING SYSTEMS CM07WD4-B

AIR CONDITIONING SYSTEMS CM07WD4-B IR CONDITIONING SYSTEMS CM07WD4-B Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity

More information

CM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008

CM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008 MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE IR CONDITIONERS Series CITY MULTI Eco Changes is the Mitsubishi Electric Group s environmental statement, and expresses the Group s stance on environmental management.

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS

More information

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM SPLIT-TYPE AIR CONDITIONERS New R410A PUMY S series up to 8* indoor units?p100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM Energy Saving Vector-Wave Eco Inverter TOP level in the industry

More information

Why Choose Mitsubishi Electric?

Why Choose Mitsubishi Electric? Air to Water Why Choose Mitsubishi Electric? In recent years, the need to be more energy conscious and environmentally responsible has become increasingly important to us all. As a leading manufacturer

More information

Building Comfort Solutions

Building Comfort Solutions R410A Building Comfort Solutions Variable Refrigerant Flow Zoning Systems R2-Series Y-Series S-Series Table of Contents Introduction........................ 2 Overview of CITY MULTI............. 4 System

More information

OUTDOOR UNITS INDOOR UNITS VENTILATION CONTROLS AND SOFTWARE TOOLS. Centralized Controller GB-50ADA...53

OUTDOOR UNITS INDOOR UNITS VENTILATION CONTROLS AND SOFTWARE TOOLS. Centralized Controller GB-50ADA...53 CITY MULTI catalog variable refrigerant flow zoning systems Version I CMTECH_5.13 I 2013 Mitsubishi Electric US, Inc. Mitsubishi Electric is a world leader in products that help people live better. When

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls 1 Article I. General Section 1.01 Section 1.02 Section 1.03 System Description Quality Assurance Storage and Handling Article

More information

CITY MULTI SYSTEM DESIGN S SERIES

CITY MULTI SYSTEM DESIGN S SERIES U11 2nd CITY MULTI SYSTEM DESIGN S SERIES 1. Electrical work... 4-4 1-1.General cautions... 4-4 1-2.Power supply for and... 4-5 1-3.Power cable specifications... 4-7 1-4.Power supply examples... 4-8 2.

More information

Control System Structure

Control System Structure Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings TM Variable Refrigerant Flow System Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R40A

More information

catalog variable refrigerant flow zoning systems FEATURING NEW CONTROLLERS MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1

catalog variable refrigerant flow zoning systems FEATURING NEW CONTROLLERS MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1 catalog variable refrigerant flow zoning systems Version I CMTECH_2.14 I 2014 Mitsubishi Electric US, Inc. I MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1 FEATURING NEW CONTROLLERS PRODUCT GUIDE

More information

MA Remote Controller PAR-31MAA

MA Remote Controller PAR-31MAA English Deutsch CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-MAA Simple Operation Manual Français Español Italiano Nederlands Português Türkçe eský Slovenský

More information

Dew point set DS 400

Dew point set DS 400 set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

Building Comfort Solutions

Building Comfort Solutions Building Comfort Solutions Variable Refrigerant Flow Zoning Systems www.mehvac.com Mitsubishi Electric is a world leader in all types of quality products. Our consumer products, like high-definition televisions

More information

Samsung SDS BMS Ver.2.0. Technical Specification

Samsung SDS BMS Ver.2.0. Technical Specification Samsung SDS BMS Ver.2.0 Technical Specification Technical Specifications All rights and title, including all intellectual property rights to Samsung SDS BMS" is retained by Samsung SDS Co, Ltd. ("SDS"),

More information

Contents. 1. Safety Precautions

Contents. 1. Safety Precautions Contents. Safety Precautions....................................... Parts Names........................................... 3 3. Screen Confi guration.................................... 6 4. Setting the

More information

Air-Conditioners PKA-A HA/PKA-A HAL PCA-A KA. Indoor unit OPERATION MANUAL. English

Air-Conditioners PKA-A HA/PKA-A HAL PCA-A KA. Indoor unit OPERATION MANUAL. English Air-Conditioners Indoor unit PKA-A HA/PKA-A HAL PCA-A KA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English

More information

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English Air-Conditioners Indoor unit PSA-RP KA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English Contents 1. Safety

More information

SERVICE MANUAL INDOOR UNIT. No. OBH788

SERVICE MANUAL INDOOR UNIT. No. OBH788 INDOOR UNIT SERVICE MANUAL. Models MSZ-AP25VG - E1, EN1 MSZ-AP35VG - E1, EN1 MSZ-AP42VG - E1, EN1 MSZ-AP50VG - E1, EN1 MSZ-AP25VGK - E1, EN1 MSZ-AP35VGK - E1, EN1 MSZ-AP42VGK - E1, EN1 MSZ-AP50VGK - E1,

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy. ENERGY RECOVERY VENTILATORS MODEL RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO and saves energy. Indoor air quality inside a building is optimised through Lossnay is a total

More information

EC-BOS-602/616 AX Security

EC-BOS-602/616 AX Security D a t a s h e e t EC-BOS-602/616 AX Security Comprehensive, easy-to-use Access Control management solution Overview The heart of EC-Net AX Security is the EC- BOS-602/616 AX Security, an advanced IP-based

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E

More information

AIR CONDITIONING SYSTEMS. Air to Water series. 2nd edition

AIR CONDITIONING SYSTEMS. Air to Water series. 2nd edition AIR CONDITIONING SYSTEMS Air to Water series nd edition Mitsubishi Electric s Air to Water Series Our solution to COOLING HEATING and HOT WATER SUPPLY Accelerating global warming The increase of the carbon

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510 Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured

More information

PEA-RP100, 125, 140GAA

PEA-RP100, 125, 140GAA Air-Conditioners PEA-RP00, 25, 40AA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English Contents.

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Operating Instructions High-spec Wired Remote Controller

Operating Instructions High-spec Wired Remote Controller Operating Instructions High-spec Wired Remote Controller Model No. CZ-RTC Installation Instructions Separately Attached. ENGLISH Before operating the unit, read these operating instructions thoroughly

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

40KMC KMQ

40KMC KMQ 40KMC------301 40KMQ------301 OWNER S MANUAL Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier

More information

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect

More information

2008 Midea Commercial A/C

2008 Midea Commercial A/C 2008 Midea Commercial A/C Controllers Control System 2008 Midea Control System & Selection Software CCM01 Indoor CCM KJR-01B(WD) Rooftop Package Unit Wired Controller MDV Central Control Monitor CCM02

More information

Corrigo E. Second generation which contains all applications and languages

Corrigo E. Second generation which contains all applications and languages revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control

More information

CATALOG VARIABLE REFRIGERANT FLOW ZONING SYSTEMS

CATALOG VARIABLE REFRIGERANT FLOW ZONING SYSTEMS CATALOG VARIABLE REFRIGERANT FLOW ZONING SYSTEMS CITY MULTI CATALOG I 05.2018 I 2018 MITSUBISHI ELECTRIC TRANE US HVAC, LLC. trane.com/ductless IFC2 TABLE OF CONTENTS.. Overview of CITY MULTI. 5 Product

More information

Buttons on remote controller

Buttons on remote controller Buttons on remote controller 1 2 3 4 5 2 1 6 7 3 8 5 6 4 7 10 8 10 15 15 ON/OFF button button MODE button SWING button FAN button Introduction for icons on display screen button TIMER OFF button CLOCK

More information

Air-Conditioners For Building Application INDOOR UNIT

Air-Conditioners For Building Application INDOOR UNIT Air-Conditioners For Building Application INDOOR UNIT PKFY-P VBM-E / PKFY-P VGM-E PKFY-P VFM-E / PMFY-P VBM-E PCFY-P VGM-E / PLFY-P VAM-E PFFY-P VKM-E OPERATION MANUAL For safe and correct use, please

More information

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment.  Heat Meter Integrator Datasheet Heat Meter Integrator Technical Overview The range of Heat Meter Integrators uses the latest innovative technology to calculate heat usage from heating and cooling systems. They are for use with

More information

Advanced Facility Air-Management Technology

Advanced Facility Air-Management Technology Internet-Enabled HVAC Monitoring & Control Maximum Digital Precision & Total Configuration Flexibility Pure and Simple Solutions Advanced Facility Air-Management Technology AbsolutAire s Facility Air-Management

More information

Architectural and Engineering Specification for a Security Management System. StarNet 2

Architectural and Engineering Specification for a Security Management System. StarNet 2 Architectural and Engineering Specification for a Security Management System StarNet 2 Jan 2, 2018 Page 1 of 12 AE-S2-IN-R1-EN-01/18 This document is intended to provide performance specifications and

More information

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1

More information

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions

More information

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable. New thinking Sentus Automation is able to control and manipulate data at ease whilst delivering a low cost per point return. XML interface: Information can be exported/viewed by an unlimited number of

More information

FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. Air-Conditioners PEA-A4,30,36,4AA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English MANUEL UTILISATION

More information

GasGard 100 Control System

GasGard 100 Control System GasGard 100 Control System Because every life has a purpose... MSA Providing Fixed Gas and Flame Detection Solutions. It is critical for plant managers and personnel to have a proactive and diagnostic

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH COMPLIANT MANAGER Model name: BMS-CM1280TLE BMS-CM1280FTLE Save These Instructions! ENGLISH Contents 1 PRECAUTIONS FOR SAFETY........................................... 3 2 PACKAGED ITEMS OF COMPLIANT

More information

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT)

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT) Manual No. '4 KX-SM-202 SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS (OUTDOOR UNIT) KXZ series (Heat pump type) Standard series Single use (Used also for combination) FDC280KXZE, 335KXZE,

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

OPERATING MANUAL UTY-RNNYM P/N English

OPERATING MANUAL UTY-RNNYM P/N English OPERATING MANUAL English UTY-RNNYM P/N9373329206-04 OPERATING MANUAL CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER... 6

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Intelligent Touch Manager

Intelligent Touch Manager Control systems Intelligent Touch Manager NEW Mini Building Management System Download the WAGO selection tool from my.daikin.eu Complete Daikin mini BMS for building climate control Integrate full Daikin

More information

ADRIA intelligent room system

ADRIA intelligent room system ADRIA intelligent room system New functions overview 2017 Contents: Residential part (rooms): 1. Access control and presence monitoring 2. Temperature control 3. Energy management 4. Hospitality 5. Security

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E

More information

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10 Company Overview Paragon Robotics wireless logging and monitoring solutions provide cost savings for powerful and scalable energy, life science, environmental and industrial systems. Add intelligent thermostats,

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display Wired remote controller (RBC-AMTE) Operation manual Parts Name of Remote Controller Display section In the display example, all indicators are displayed for the explanation. In reality only, the selected

More information

PUMY-P125VMA PUMY-P125VMA1 PUMY-P125YMA PUMY-P125YMA1

PUMY-P125VMA PUMY-P125VMA1 PUMY-P125YMA PUMY-P125YMA1 SPLIT-TYPE, HEAT PMUP AIR CONDITIONERS 004 No.OC7 REVISED EDITION-B TECHNAL & SERVE MANUAL R407C Outdoor unit [Model name] PUMY-P5VMA PUMY-P5YMA [Service Ref.] PUMY-P5VMA PUMY-P5VMA PUMY-P5YMA PUMY-P5YMA

More information

Product Launch SHRMi

Product Launch SHRMi Product Launch SHRMi What s SHRM i SMMS i (High Efficiency & Reliability) Simultaneous Operation by heat recovery + = SHRM i meets various customers needs! Refrigerant flow, cooling Liquid pipe Flow selector

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

HEAT HEAT HEAT COOL COOL

HEAT HEAT HEAT COOL COOL OWNER S MANUAL AUTO 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL COMMERCIAL THERMOSTAT P/N P374-2700 HEAT PUMP NON-PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2 Heat & 2 Cool Stages

More information

Flair 500 Series Annunciators

Flair 500 Series Annunciators Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other

More information

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE. LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE. LENNOX MINI-VRF MAKES MULTI-ZONE COMFORT EASY AND EFFICIENT. Available in 3- to 5-ton configurations, with options to control up to 9 zones,

More information

ACP Advanced Control Platform (PQCPA11A0E, PQCPB11A0E) Installation/Owner's Manual

ACP Advanced Control Platform (PQCPA11A0E, PQCPB11A0E) Installation/Owner's Manual LG Advanced Control Platform (PQCPA11A0E, PQCPB11A0E) Installation/Owner's Manual Caution Read this manual thoroughly before installing the product. Only the certified professional should install this

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website General/Operational Troubleshooting Guide I have an Error Code: E0 (Thermostat

More information

EDUS M. General Information. RXYQ-TYDN 3 phase, 460V, 60Hz. RXYQ-TTJU 3 phase, 208/230V, 60Hz

EDUS M. General Information. RXYQ-TYDN 3 phase, 460V, 60Hz. RXYQ-TTJU 3 phase, 208/230V, 60Hz EDUS341411-M General Information RXYQ-TYDN 3 phase, 460V, 60Hz RXYQ-TTJU 3 phase, 208/230V, 60Hz EDUS341411-M General Information... EDUS341411-M (This booklet) Indoor Units Ceiling Mounted Cassette Type

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS PROGRAMMABLE THERMOSTAT MODEL 3314080.000 BLACK 3314080.015 WHITE USA SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN 46514

More information

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs) PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs) FEATURES OF AIVIA PROTECTION MODELS H : 423 mm The Aivia range has been designed and manufactured by the French company

More information

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:

More information

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications LYNX CE CENTRAL CONTROL FOR OSMAC General Specifications Number of satellites: Up to 255 Number of satellite stations: up to 16,320 Number of Courses: 3 Number of holes per course: 48 Number of holes per

More information

Addressable Fire Alarm Control System 2100 series

Addressable Fire Alarm Control System 2100 series Addressable Fire Alarm Control System 2100 series It adopts new generation high-speed microprocessor technology that has a data processing speed and a data storage capacity 100 times and 1000 times higher

More information

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No. AIR CONDITIONER OPERATING MANUAL Duct type Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE PART No. 98067 98067_OM_EN.indd 07-Aug-5 :40:5 OPERATING MANUAL PART No. 98067

More information

System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are:

System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are: System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are: Product I141DX I121DX I151SX-ALARM Description Alarm interface with 8 alarm inputs and 8 AUX outputs,

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379583 CONTENTS SAFETY PRECAUTIONS... 2 FEATURES AND FUNCTIONS...

More information

Air-Conditioners Indoor unit

Air-Conditioners Indoor unit Air-Conditioners Indoor unit PLA-A AA PKA-A A/PKA-A AL PKA-A FA/PKA-A FAL PCA-A A eutsch Nederlands Español Italiano ÏÏËÓÈÎ Português ansk Svenska OPERATI MANUAL FOR USER For safe and correct use, please

More information

Manual & Technical Documentation V1.1

Manual & Technical Documentation V1.1 Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special

More information

Taking control of your energy use

Taking control of your energy use Controls Taking control of your energy use Increasing energy bills, the need to reduce carbon emissions and a raft of challenging legislation are driving the demand for increased energy efficiency in our

More information

Frequently asked questions: Intelligent Transmitter Series

Frequently asked questions: Intelligent Transmitter Series Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHBH04CB EHBH08CB EHBHCB EHBH6CB EHBX04CB EHBX08CB EHBXCB EHBX6CB EHVH04S8CB EHVH08S8CB EHVH08S6CB EHVHS8CB EHVHS6CB EHVH6S8CB EHVH6S6CB EHVX04S8CB EHVX08S8CB EHVX08S6CB EHVXS8CB EHVXS6CB EHVX6S8CB EHVX6S6CB

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER 24V Thermostat Interface Model name: TCB-IFTH1GUL FOR INSTALLER Read this manual before using the TCB- IFTH1GUL 24V Thermostat Interface. Refer to installation manuals supplied with Indoor Unit, Remote

More information

PRODUCT LINEUP & OPTIONAL PARTS

PRODUCT LINEUP & OPTIONAL PARTS 148 PRODUCT LINEUP & OPTIONAL PARTS 150 OVERVIEW For SPLIT & MULTI SPLIT For 154 Comparison Table of s INDIVIDUAL CONTROL 157 Wired Remote (Touch Panel) 158 Wired Remote 159 Simple Remote 160 Wireless

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

DATAssure. Laboratory wireless alarm & monitoring system

DATAssure. Laboratory wireless alarm & monitoring system DATAssure Laboratory wireless alarm & monitoring system Wireless alarm & monitoring system A new monitoring generation The DATAssure wireless monitoring system is used across a broad range of market sectors

More information