DESIGN & TECHNICAL MANUAL

Size: px
Start display at page:

Download "DESIGN & TECHNICAL MANUAL"

Transcription

1 AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA

2 . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA DTR_AU47E_ 3..8

3 . INDOOR UNIT CONTENTS. FEATURES REMOTE CONTROLLER SPECIFICATIONS DIMENSIONS WIRING DIAGRAMS CAPACITY TABLE COOLING CAPACITY HEATING CAPACITY FAN PERFORMANCE AIR VELOCITY DISTRIBUTION AIRFLOW OPERATION NOISE NOISE LEVEL CURVE SOUND LEVEL CHECK POINT ELECTRIC CHARACTERISTICS SAFETY DEVICES EXTERNAL INPUT & OUTPUT EXTERNAL INPUT EXTERNAL OUTPUT FUNCTION SETTINGS INDOOR UNIT INDOOR UNIT (Setting by remote controller) OPTIONAL PARTS CONTROLLER CASSETTE GRILLE OTHERS

4 - ( - ) - FEATURES MODEL AU GLVLB / AO GLALL AU G4LVLB / AO G4LALL AU G8LVLB / AO G8LALL AU G4LVLA / AO G4LALA FEATURES zenergy efficiency class MODEL AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA Cooling A++ A++ A++ A+ Heating A+ A+ A+ A z-stage turbo fan Wind velocity Fast Slow High efficiency design by stage structure Previous turbo fan In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. -stage turbo fan A evenly spread air distribution across the heat exchanger is possible due to the new stage turbo fan which produces two separate airflow streams. -stage Heat exchange efficiency: %UP + -stage stage zquiet quality Optimization of wing form (laminar wing type) and wing number (7 blades each) Designed by CFD-analysis (fluid) simulations Laminar wing Airflow runs through smoothly along the laminar wing Quiet No airflow separation Quiet Adoption of laminar wing Spin direction Airflow direction zeasy maintenance Maintenance of fan motor and fan Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. A : Fan motor B : -stage turbo fan C : Bell-mouth D : Panel A Long life filter B C : standard equipment D 3 Adaptation of transparent drainage parts During installation, maintenance and operation, the drain pump and Grille cover kit can be checked easily. zcompact design Easy installation by taking off ceiling panel of 6mm x 6mm size 57mm 57mm zeasy installation zhigh lift drain pump Easy setting by wireless or wired remote controller 7mm

5 - ( - ) - z C HEAT Operation The room temperature can be set to go no lower than C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC. Caution) When the room temperature is higher than C, C HEAT operation will not start. Operation starts and maintains the room temperature at C when the temperature drops below C. When C HEAT operation stops, the room set temperature quickly returns to the preset temperature. C C HEAT Button ON Indoor unit operation START C zeconomy operation The power consumption can be reduced. FUNCTION SETTING zoutlet direction selection Performs operation matched to the number of outlets when 4 directions are unnecessary and outlets are blocked when the ceiling cassette is installed in a corner, etc. 4-way direction 3-way direction 4-way direction mode: Set when there are 4 outlets (shipped state). 3-way direction mode: Set when there are 3 outlets. zceiling switching function Air reaches sufficiently up to 3m height, even it is compact cassette type. Also delivers air to high ceilings by selecting the mode and raising the air flow according to the height of the ceiling. High ceiling (Mode ) Standard ceiling (Standard) 3m.7m Standard...Operates at normal air flow. Mode...Air flow becomes greater than normal. zcooling room temperature correction zheating room temperature correction zauto restart The units restart automatically when the current was returned even when there was a power interruption during operation.

6 - ( - 3) - REMOTE CONTROLLER WIRELESS REMOTE CONTROLLER FEATURES ¾¾4 mode timer setup available (ON / OFF / PROGRAM / SLEEP) ¾¾Easy operation. ¾¾Easy to change signal code (max. 4 units) by button operation. zsimple function setting Setting of the air conditioner selection function is performed by remote controller. zbuilt-in timers Select from four different timer programs (ON / OFF / PROGRAM / SLEEP). zprogram timer The program timer operates the on and off timer once within a 4 hour period. zsleep timer The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping. Cooling operation/dry operation When the sleep timer is set, the set temperature automatically rises C every hour. The set temperature can rise up to a maximum of C. Heating operation When the sleep timer is set, the set temperature automatically drops C every 3 minutes. The set temperature can drop to a maximum of 4 C. Timer setting C C 3 C 4 C 6min. 3min. C C 6min. 9min. Timer setting zswitching remote controller signal code After code change Mixed-up A B C D I.U. I.U. I.U. I.U. I.U. I.U. I.U. I.U. A B C D Code selector switch eliminates unit being wrongly switched. (Up to 4 codes can be set.) *I.U.=Indoor unit

7 - ( - 4) - FUNCTIONS 5 MODE button Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT). /Start / end R.C. signal code change. (Max 4 types) C HEAT button 33 SET TEMP. button ( / ) Sets the indoor temp./ Sets R.C. signal code. 44 ECONOMY button 55 SLEEP button Pressed to select sleep timer FAN button Selects the fan speed (AUTO, HIGH, MED, LOW, QUIET). START/STOP button Pressed to start and stop operation. SET button (Vertical) Air flow direction vertical set button. SWING button Air flow direction swing button. TIMER MODE button Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET) TIMER SET ( + / - ) button Sets the current time and on-off time. CLOCK ADJUST button Sets the current time. RESET button Used when replacing batteries. TEST RUN button Used when testing the air conditioner after installation. Signal transmitter Display panel Temperature set display Operating mode display 6 9 Sleep display Transmit indicator Fan speed display 7 Swing display Timer mode display Clock display 8 3 Note: Functions will be different due to type of indoor unit. For details, please see operation manual. SPECIFICATION SIZE (H W D mm) WEIGHT (g) 85 (w/o batteries) ACCESSORY Holder

8 - ( - 5) - 333SPECIFICATIONS Type Model name Power source Available voltage range Capacity Input power Current Cooling Heating Cooling Heating Rated Min. - Max. Rated Min. - Max. Rated CASSETTE MODEL INVERTER HEATPUMP Indoor unit AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA Outdoor unit AO GLALL AO G4LALL AO G8LALL AO G4LALA 3V ~ 5Hz 98-64V ~ 5Hz kw Btu/h kw Btu/h kw Btu/h kw Btu/h *Max kw Rated *Max Cooling Rated A Heating EER Cooling kw / kw COP Heating Moisture removal l/h (pints/h). (. ).5 (.6 ). ( 3.9 ).7 ( 4.8 ) Maximum operating current * Fan Sound pressure level Heat exchanger type Dimensions (H W D) Weight Connection pipe Operation range Cassette grille Remote controller type Airflow rate Cooling A Heating Cooling Heating High Med Low Quiet m 3 /h High Med Low Quiet Type Q'ty Turbo Motor output W 54 Size Method Cooling Heating High Dimensions (H W D) mm Med Low Quiet db (A) High Med Low Quiet Fin pitch..45 Rows Stages 3 Pipe type Fin type Copper tube Aluminium Net mm Gross Net 5 6 kg Gross 8 9 Liquid Ø 6.35 (Ø / 4 in.) mm Gas Ø9.5 (Ø3/8 in.) Ø.7 (Ø/ in.) Ø5.88 (Ø5/8 in.) Cooling Flare C 8 to 3 %RH 8 or less Heating C 6 to 3 Model name Material Colour Dimensions (H W D) Weight UTG-UF D-W PS WHITE Approximate colour of MUNSELL N 9.5 / Net mm Gross Net.6 kg Gross 4.5 Wireless [Wired (option)] Material PVC Drain hose Size mm VP5 [Ø5(I.D.),Ø3(O.D.)] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 7 CDB / 9 CWB. and outdoor temperature of 35 CDB / 4 CWB. Heating : Indoor temperature of CDB / 5 CWB. and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 5. m, Height difference : m. (Outdoor unit - Indoor unit) Ceiling mode : Standard *The maximum current and the maximum input value are the maximum value when operated within the operation range. The protective function might work when using outside the operation range.

9 - ( - 6) - Model name AUÜGLVLB AUÜG4LVLB AUÜG8LVLB AUÜG4LVLA Energy efficiency class Cooling A++ A++ A++ A+ Heating (Average) A+ A+ A+ A Pdesign Cooling 3.5 (35 C) 4.3 (35 C) 5. (35 C) 6.8 (35 C) kw Heating (Average) 4. (- C) 4.5 (- C) 5. (- C) 6. (- C) SEER Cooling kwh/kwh SCOP Heating (Average) Annual energy consumption QCE kwh/a QHE (Average) Sound power level Cooling High db (A) Heating

10 - ( - 7) - 444DIMENSIONS MODEL: AU GLVLB, AU G4LVLB, AU G8LVLB, AU G4LVLA 53: Hanging bolt position Cassette grille mounting state Unit : mm 35 5 (Drain hose) to 54: Hanging bolt position 57: Indoor unit 58 to 66 : Ceiling openings Top view Min. 45 Service access Be sure to leave service access for future service at the designated position. Drain port 4 99 Min. 45 Drain port Control box Side view Ceiling Side view 7 Bottom view AU GLVLB AU G4LVLB, AU G8LVLB AU G4LVLA Refrigerant pipe flare Liquid ø 6.35 mm (ø /4 in.) ø 6.35 mm (ø /4 in.) ø 6.35 mm (ø /4 in.) connection Gas ø 9.5 mm (ø 3/8 in.) ø.7 mm (ø / in.) ø 5.88 mm (ø 5/8 in.) Drain hose connection Drain hose VP5[ ø 5(I.D.)ø 3(O.D.)]

11 - ( - 8) - INSTALLATION PLACE Strong and durable ceiling Unit : mm 6 or more H 8 or more Obstruction Floor or more or more H (The maximum height from floor to ceiling) Unit: mm Model name AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA Standard mode High Ceiling mode z3-way directions setting * or more To set 3-way directions, the air outlet shutter plate (UTR-YDZB) sold separately must be installed and outlet-direction switched to 3-way by remote controller. *When installing the indoor unit, be careful about the maintenance space.

12 - ( - 9) - 555WIRING DIAGRAMS MODEL: AU GLVLB, AU G4LVLB, AU G8LVLB, AU G4LVLA

13 - ( - ) - 666CAPACITY TABLE 66666COOLING CAPACITY This table is created using the maximum capacity. MODEL: AU GLVLB AFR. Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP MODEL: AU G4LVLB AFR.3 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP MODEL: AU G8LVLB AFR.3 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP AFR : Air Flow Rate (m 3 /min) TC : Total Capacity (kw) SHC : Sensible Heat Capacity (kw) IP : Input Power (kw)

14 - ( - ) - MODEL: AU G4LVLA AFR 5.5 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP AFR : Air flow rate (m 3 /min) TC : Total capacity (kw) SHC : Sensible Heat capacity (kw) IP : Input Power (kw)

15 - ( - ) HEATING CAPACITY This table is created using the maximum capacity. MODEL: AU GLVLB AFR. Outdoor temperature Indoor temperature CDB CDB CWB TC IP TC IP TC IP TC IP TC IP MODEL: AU G4LVLB AFR 3.3 Outdoor temperature Indoor temperature CDB CDB CWB TC IP TC IP TC IP TC IP TC IP MODEL: AU G8LVLB AFR 3.3 Outdoor temperature Indoor temperature CDB CDB CWB TC IP TC IP TC IP TC IP TC IP AFR : Air Flow Rate (m 3 /min) TC : Total Capacity (kw) IP : Input Power (kw)

16 - ( - 3) - MODEL: AU G4LVLA AFR 5.5 Outdoor temperature Indoor temperature CDB CDB CWB TC IP TC IP TC IP TC IP TC IP AFR : Air Flow Rate (m 3 /min) TC : Total Capacity (kw) IP : Input Power (kw)

17 - ( - 4) - 777FAN PERFORMANCE 77777AIR VELOCITY DISTRIBUTION MODEL: AU GLVLB z4-way air outlet Note: Condition Fan speed : High Operation mode : Fan Ceiling mode : Standard 4 Unit : m/s TOP VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Downward

18 - ( - 5) - Note: Condition Fan speed : High z3-way air outlet Operation mode : Fan Ceiling mode : Standard 4 Unit : m/s 3 TOP VIEW VERTICAL LOUVER : Upward Unit : m/s SIDE VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Downward

19 - ( - 6) - MODEL: AU G4LVLB z4-way air outlet Note: Condition Fan speed : High Operation mode : Fan Ceiling mode : Standard Unit : m/s TOP VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Downward

20 - ( - 7) - Note: Condition Fan speed : High z3-way air outlet Operation mode : Fan Ceiling mode : Standard 4 Unit : m/s 3 TOP VIEW VERTICAL LOUVER : Upward Unit : m/s SIDE VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Downward

21 - ( - 8) - MODEL: AU G8LVLB z4-way air outlet Note: Condition Fan speed : High Operation mode : Fan Ceiling mode : Standard 4 Unit : m/s TOP VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Downward

22 - ( - 9) - Note: Condition Fan speed : High z3-way air outlet Operation mode : Fan Ceiling mode : Standard 4 Unit : m/s 3 TOP VIEW VERTICAL LOUVER : Upward Unit : m/s SIDE VIEW VERTICAL LOUVER : Upward 3 Unit : m/s SIDE VIEW VERTICAL LOUVER : Downward

23 - ( - ) - Note: MODEL: AU G4LVLA z4-way air outlet Condition Fan speed : High Operation mode : FAN Ceiling mode : Standard 4 Unit : m/s TOP VIEW VERTICAL FLAP : Upward 3 Unit : m/s SIDE VIEW VERTICAL FLAP : Upward 3 Unit : m/s SIDE VIEW VERTICAL FLAP : Downward

24 - ( - ) - Note: MODEL: AU G4LVLA z3-way air outlet Condition Fan speed : High Operation mode : FAN Ceiling mode : Standard 4 Unit : m/s TOP VIEW VERTICAL FLAP : Upward 3 Unit : m/s SIDE VIEW VERTICAL FLAP : Upward 3 Unit : m/s SIDE VIEW VERTICAL FLAP : Downward

25 - ( - ) AIRFLOW STANDARD CEILING MODE MODEL: AU GLVLB zcooling Fan speed Number of rotations (r.p.m) Airflow m 3 /h 6 HIGH 65 l/s 67 CFM 353 m 3 /h 53 MED 58 l/s 47 CFM 3 m 3 /h 47 LOW 5 l/s 3 CFM 77 m 3 /h 4 QUIET 46 l/s 4 CFM 4 zheating Fan speed Number of rotations (r.p.m) Airflow m 3 /h 6 HIGH 65 l/s 67 CFM 353 m 3 /h 53 MED 58 l/s 47 CFM 3 m 3 /h 47 LOW 5 l/s 3 CFM 77 m 3 /h 4 QUIET 46 l/s 4 CFM 4

26 - ( - 3) - MODEL: AU G4LVLB zcooling Fan speed Number of rotations (r.p.m) Airflow m 3 /h 68 HIGH 73 l/s 89 CFM 4 m 3 /h 58 MED 63 l/s 6 CFM 34 m 3 /h 49 LOW 54 l/s 36 CFM 88 m 3 /h 4 QUIET 46 l/s 4 CFM 4 zheating Fan speed Number of rotations (r.p.m) Airflow m 3 /h 8 HIGH 83 l/s CFM 47 m 3 /h 68 MED 73 l/s 89 CFM 4 m 3 /h 58 LOW 63 l/s 6 CFM 34 m 3 /h 45 QUIET 5 l/s 5 CFM 65

27 - ( - 4) - MODEL: AU G8LVLB zcooling Fan speed Number of rotations (r.p.m) Airflow m 3 /h 68 HIGH 73 l/s 89 CFM 4 m 3 /h 58 MED 63 l/s 6 CFM 34 m 3 /h 49 LOW 54 l/s 36 CFM 88 m 3 /h 4 QUIET 46 l/s 4 CFM 4 zheating Fan speed Number of rotations (r.p.m) Airflow m 3 /h 8 HIGH 83 l/s CFM 47 m 3 /h 68 MED 73 l/s 89 CFM 4 m 3 /h 58 LOW 63 l/s 6 CFM 34 m 3 /h 45 QUIET 5 l/s 5 CFM 65

28 - ( - 5) - MODEL: AU G4LVLA zcooling Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 93 HIGH 96 l/s 58 CFM 547 m 3 /h 83 MED 85 l/s 3 CFM 488 m 3 /h 6 LOW 65 l/s 67 CFM 353 m 3 /h 45 QUIET 5 l/s 5 CFM 65 Heating z Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 93 HIGH 96 l/s 58 CFM 547 m 3 /h 86 MED 88 l/s 39 CFM 56 m 3 /h 7 LOW 74 l/s 94 CFM 4 m 3 /h 53 QUIET 58 l/s 47 CFM 3

29 - ( - 6) HIGH CEILING MODE MODEL: AU GLVLB zcooling Fan speed Number of rotations (r.p.m) Airflow m 3 /h 7 HIGH 75 l/s 94 CFM 4 m 3 /h 63 MED 68 l/s 75 CFM 37 m 3 /h 57 LOW 6 l/s 58 CFM 335 m 3 /h 4 QUIET 46 l/s 4 CFM 4 zheating Fan speed Number of rotations (r.p.m) Airflow m 3 /h 7 HIGH 75 l/s 94 CFM 4 m 3 /h 63 MED 68 l/s 75 CFM 37 m 3 /h 57 LOW 6 l/s 58 CFM 335 m 3 /h 4 QUIET 46 l/s 4 CFM 4

30 - ( - 7) - MODEL: AU G4LVLB zcooling Fan speed Number of rotations (r.p.m) Airflow m 3 /h 8 HIGH 83 l/s CFM 47 m 3 /h 68 MED 73 l/s 89 CFM 4 m 3 /h 59 LOW 64 l/s 64 CFM 347 m 3 /h 4 QUIET 46 l/s 4 CFM 4 zheating Fan speed Number of rotations (r.p.m) Airflow m 3 /h 9 HIGH 93 l/s 5 CFM 53 m 3 /h 8 MED 83 l/s CFM 47 m 3 /h 68 LOW 73 l/s 89 CFM 4 m 3 /h 45 QUIET 5 l/s 5 CFM 65

31 - ( - 8) - MODEL: AU G8LVLB zcooling Fan speed Number of rotations (r.p.m) Airflow m 3 /h 8 HIGH 83 l/s CFM 47 m 3 /h 68 MED 73 l/s 89 CFM 4 m 3 /h 59 LOW 64 l/s 64 CFM 347 m 3 /h 4 QUIET 46 l/s 4 CFM 4 zheating Fan speed Number of rotations (r.p.m) Airflow m 3 /h 9 HIGH 93 l/s 5 CFM 53 m 3 /h 8 MED 83 l/s CFM 47 m 3 /h 68 LOW 73 l/s 89 CFM 4 m 3 /h 45 QUIET 5 l/s 5 CFM 65

32 - ( - 9) - MODEL: AU G4LVLA zcooling Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 3 HIGH 5 l/s 86 CFM 66 m 3 /h 93 MED 95 l/s 58 CFM 547 m 3 /h 7 LOW 75 l/s 97 CFM 48 m 3 /h 45 QUIET 5 l/s 5 CFM 65 Heating z Fan speed Number of rotations (r.p.m.) Airflow m 3 /h HIGH 3 l/s 78 CFM 589 m 3 /h 96 MED 98 l/s 67 CFM 565 m 3 /h 8 LOW 84 l/s 8 CFM 483 m 3 /h 53 QUIET 58 l/s 47 CFM 3

33 - ( - 3) - 888OPERATION NOISE 88888NOISE LEVEL CURVE MODEL: AU GLVLB zcooling zheating Octave band sound pressure level, db:(db=.µbar) QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz MODEL: AU G4LVLB zcooling 8 zheating Octave band sound pressure level, db:(db=.µbar) QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz

34 - ( - 3) - MODEL: AU G8LVLB zcooling zheating Octave band sound pressure level, db:(db=.µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz MODEL: AU G4LVLA zcooling 8 zheating Octave band sound pressure level, db:(db=.µbar) QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz

35 - ( - 3) SOUND LEVEL CHECK POINT Microphone Microphone

36 - ( - 33) - 999ELECTRIC CHARACTERISTICS Model Name AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA Voltage V 3 ~ Power Supply Frequency Hz 5 Max Operating Current A Connection Cable mm.5 *) Wiring Spec. Limited wiring length m 6 3 *) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E5)

37 - ( - 34) - SAFETY DEVICES Model Protection form AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA Circuit protection Current fuse (PCB) 5V 3.5A Fan motor protection Thermal protection program 38 ± 5 C OFF 5 ± C ON

38 - ( - 35) - EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN Control input CN3 Operation status output CN6 Fresh air control output See external input/output settings for details. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit. Unit operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a connector on the external control PC board and turning it ON. Unit operation Initial setting after turned power ON Starting mode other than initial setting Operation mode Auto changeover Mode at previous operation Set temperature 4 C Temperature at previous operation Air flow mode AUTO Mode at previous operation Up-down air direction (swing) Standard air direction (swing OFF) Air direction at previous operation Left-right air direction (swing) Standard air direction (swing OFF) Air direction at previous operation zcircuit diagram example Indoor control PC board Connected unit Connector 3 * m Ex.) Switch Contact capacity : 4VDC or more, ma or more. Please use non-polar relays and switches. Signal Field supply * Make the distance from the PC board to the connected unit within m. When function setting is in "Operation/Stop" mode Input signal Indoor unit ON OFF Operation Stop When function setting is in "Forced stop" mode Input signal ON OFF Command Forced stop Normal Indoor unit Operation Stop Remote controller ON ON ON zparts (Optional) Model name UTY-XWZX Wire (External input) Remote control operation invalidity

39 - ( - 36) - EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. zcircuit diagram example Indoor control PC board Connected unit Connector 4V DC V Ex.)Relay unit Ex.)Display Relay power supply * m Signal Field supply * Make the distance from the PC board to the connected unit within m. Relay spec. : Max.4VDC, ma to less than 5mA. Indoor unit Output signal Operation Stop ON OFF zparts (Optional) Model name UTY-XWZX Wire (External output)

40 - ( - 37) - FRESH AIR CONTROL OUTPUT A signal linked to air conditioner indoor fan ON can be output. * However, signal becomes OFF during cold air prevention control operation. zcircuit diagram example Indoor control PC board V on/off Connector Ex.) Relay unit Connected unit Ex.) Fan Relay power supply * m Signal Field supply * Make the distance from the PC board to the connected unit within m. Relay spec. : Rated VDC, 5mA or less. Indoor fan Output signal Operation Stop ON OFF zparts (Optional) Model name UTZ-VXAA * Wire (Fresh air output) Note This wire is included in Fresh air intake kit (UTZ-VXAA)

41 - ( - 38) - FUNCTION SETTINGS INDOOR UNIT DIP SW 3 4 JM Jumper Wire JM JM3 INDOOR UNIT Remote controller address setting Setting forbidden SWITCH POSITION MAIN PCB Indoor unit Printed circuit board JM3 JM JM DIP-SW SETTING zremote controller address setting A number of indoor units can be operated at the same time using a wired remote controller. Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board. (See the following table.) The DIP switches are normaly set to make the unit number. (...Factory setting) Remote controller address DIP switch No. 3 4 OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON OFF ON OFF ON ON ON OFF ON OFF OFF ON ON 3 ON OFF ON ON 4 OFF ON ON ON 5 ON ON ON ON

42 - ( - 39) - INDOOR UNIT (Setting by remote controller) The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. After the power is turned on, perform the FUNCTION SETTING according to the installation conditions using the remote controller. The settings may be selected between the following two: Function Number or Setting Value. Settings will not be changed if invalid numbers or setting values are selected. PREPARATION Turn on the power. * Before turning on the power of the indoor units, make sure the piping air-tight test and vacuuming have been conducted. * Also check again to make sure no wiring mistakes were made before turning on the power. FUNCTION SETTING METHOD (for Wireless remote controller) Entering the Function Setting Mode While pressing the FAN button and SET TEMP. ( ) simultaneously, press the RESET button to enter the function setting mode. STEP Setting the Remote controller Signal Code Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) The signal codes that are set through this process are applicable only to the signals in the FUNCTION SETTING. For details on how to set the signal codes through the normal process, refer to REMOTE CONTROLLER SIGNAL CODE SETTING. Press the SET TEMP. ( ) ( ) button to change the signal code between Match the code on the display to the air conditioner signal code. (initially set to ) (If the signal code does not need to be selected, press the MODE button and proceed to STEP.) Press the TIMER MODE button and check that the indoor unit can receive signals at the displayed signal code. 333 Press the MODE button to accept the signal code, and proceed to STEP. The air conditioner signal code is set to A prior to shipment. The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting, try each of the signal codes ( ) until you find the code which operates the air conditioner. STEP Selecting the Function Number and Setting Value Press the SET TEMP. ( ) ( ) buttons to select the function number. (Press the MODE button to switch between the left and right digits.) Press the FAN button to proceed to setting the value. Press the FAN button again to return to the function number selection.) 333 Press the SET TEMP. ( ) ( ) buttons to select the setting value. (Press the MODE button to switch between the left and right digits.) 444 Press the TIMER MODE button, and START/STOP button, in the order listed to confirm the settings. 555 Press the RESET button to cancel the function setting mode. 666 After completing the FUNCTION SETTING, be sure to turn off the power and turn it on again. Function number Setting value CAUTION The Function Setting will not become active unless the power is turned off then on again.

43 - ( - 4) - CONTENTS OF FUNCTION SETTING Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in accordance with the installed condition. After the power is turned on, perform the Function Setting on the remote control. The settings may be selected between the following two: Function Number or Setting Value. Settings will not be changed if invalid numbers or setting values are selected. ) Filter sign ) Ceiling height 3) Outlet directions 4) Cooler room temperature correction 5) Heater room temperature correction 6) Auto restart 7) Indoor room temperature sensor switching function 8) Remote controller signal code 9) External input control ) Indoor unit fan control for energy saving ) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time setting for the filter sign display interval in the table below according to the amount of dust or debris in the room. If you do not wish the filter sign to be displayed, select the setting value for "No indication". (...Factory setting) Setting Description Function Number Setting Value "Standard (,5 hours)" "Long interval (4,4 hours)" "Short interval (,5 hours)" No indication 3 ) Ceiling height Select the setting values in the table below according to the height of the ceiling. (...Factory setting) Setting Description Function Number Setting Value Standard (.7m) High ceiling (3.m) The ceiling height values are for the 4-way outlet. Do not change this setting in the 3-way outlet mode. 3) Outlet directions Select the setting values in the table below for using a 3-way outlet. (...Factory setting) Setting Description Function Number Setting Value 4-way 3-way

44 4) Cooler room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be selected as shown in the table below. (...Factory setting) Setting Description Function Number Setting Value Standard Slightly lower control 3 Lower control Warmer control 3 5) Heater room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below. (...Factory setting) Setting Description Function Number Setting Value Standard Lower control 3 Slightly warmer control Warmer control 3 6) Auto restart Enable or disable automatic system restart after a power outage. (...Factory setting) Setting Description Function Number Setting Value Yes 4 No * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate using the remote controller,or external input device. 7) Indoor room temperature sensor switching function (Only for Wired remote controller) The following settings are needed when use the control by Wired remote controller temperature sensor. (...Factory setting) Setting Description Function Number Setting Value No 4 Yes If setting value is, room temperature is controlled by the indoor unit temperature sensor. If setting value is, room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor. 8) Remote controller signal code Change the indoor unit Signal Code,depending on the remote controllers. Setting Description Function Number Setting Value A B 44 C D 3 9) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. (... Factory setting) Setting description Function number Setting value Operation/Stop mode (Setting forbidden) 46 Forced stop mode - ( - 4) -

45 - ( - 4) - ) Indoor unit fan control for energy saving (Only cooling mode) Enable or disable indoor unit fan control when the outdoor unit is stopped. (...Factory setting) Setting Description Function Number Setting Value No 49 Yes *If setting value is : When the outdoor unit is stopped, the indoor unit fan operates following the setting on the remote controller continuously. *If setting value is : When the outdoor unit is stopped, the indoor unit fan operates at very low speed intermittently.

46 - ( - 43) - REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.). Press the START/STOP button until only the clock is displayed on the remote controller display.. Press the MODE button for at least five seconds to display the current signal code (initially set to ). 3. Press the SET TEMP. ( ) ( ) button to change the signal code between. Match the code on the display to the air conditioner signal code. 4. Press the MODE button again to return to the clock display. The signal code will be changed. If no buttons are pressed within 3 seconds after the signal code is displayed, the system returns to the original clock display. In this case, start again from step. The air conditioner signal code is set to A prior to shipment. Contact your retailer to change the signal code. The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting,try each of the signal codes (.) until you find the code which operates the air conditioner.

47 - ( - 44) - OPTIONAL PARTS CONTROLLER Exterior Parts name Model No. Summary Wired Remote Controller UTY-RVN M Large and full-dot liquid crystal screen, wide and large keys easy to press, user-intuitive arrow key. Wired remote controller UTY-RNN M Unit control is performed by wired remote controller Simple remote controller UTY-RSN M Unit control is performed by simple remote controller CASSETTE GRILLE Exterior Parts name Model No. Summary Cassette grille UTG-UF D-W Ceiling dirt by discharged wind was made difficult to cling by reviewing the shape of the LOUVER.

48 - ( - 45) - OTHERS Exterior Parts name Model No. Summary Air outlet shutter plate UTR-YDZB Air outlet shutter plate is installed at the air outlet when 3-way direction is performed. Insulation Kit Insulation kit for high humidity UTZ-KXGC Install when the under roof condition is expected to be the humidity of over 8 % and the temperature of over 3 C Fresh air intake kit UTZ-VXAA It can be taken in fresh air of up to % of high air volume of the indoor unit by attaching Fresh Air Intake Kit to cassette type indoor unit. External connect set UTY-XWZX Use to connect with various peripheral devices and air conditioner PC board.

49 . SINGLE TYPE : AO GLALL AO G4LALL AO G8LALL AO G4LALA DTR_AO99E_ 3..8

50 CONTENTS AO G-4LAL.. SPECIFICATIONS DIMENSIONS... - AO G-4LAL 3. REFRIGERANT CIRCUIT WIRING DIAGRAMS CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE ADDITIONAL CHARGE CALCULATION AIRFLOW OPERATION NOISE (SOUND PRESSURE) NOISE LEVEL CURVE SOUND LEVEL CHECK POINT ELECTRIC CHARACTERISTICS SAFETY DEVICES

51 - ( - ) - SPECIFICATIONS AO G-4LAL Type INVERTER HEAT PUMP Model name AO GLALL AO G4LALL AO G8LALL AO G4LALA Power source 3V ~ 5Hz Available voltage range 98-64V ~ 5Hz Starting current A Cooling Airflow rate m 3 /h Heating Fan Type Q'ty Propeller Motor output W Sound pressure level Cooling db (A) Heating Sound power level Cooling db (A) Heating Dimensions (H W D) mm Fin pitch.3.4 Heat exchanger type 6 Rows Stages 6 4 Pipe type Copper Fin Type Aluminium Compressor Type Q'ty Twin Rotary Motor output W Type Refrigerant (Global Warming Potential) R4A(975) Charge g Refrigerant oil Type POE Material Steel sheet Enclosure Beige Colour Approximate colour of MUNSELL YR7.5/. Dimensions Net mm (H W D) Gross Weight Net 4 44 kg Gross Size Liquid Ø6.35 (Ø/4 in.) mm Gas Ø9.5 (Ø3/8 in.) Ø.7 (Ø/ in.) Ø5.88 (Ø5/8 in.) Connenction pipe Method Flare Pre-charge length 5 Max. length m 5 3 Max. height difference 5 Operation range Cooling - to 46 C Heating -5 to 4 Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 7 CDB / 9 CWB.and outdoor temperature of 35 CDB / 4 CWB. Heating : Indoor temperature of CDB / 5 CWB.and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 5. m, Height difference : m. (Outdoor unit - Indoor unit) The protective function may work when using it outside the operation range. AO G-4LAL

52 - ( - ) - DIMENSIONS MODEL: AO GLALL, AO G4LALL, AO G8LALL, AO G4LALA (Unit : mm) AO G-4LAL Top view AO G-4LAL Front view Air flow AO GLALL AO G4LALA AO G4LALL AO G8LALL Side view Bottom view INSTALLATION PLACE When there are obstacles at the back or front sides. When there are obstacles at the back, side(s), and top. 6 mm or more When there are obstacles at the back, side with the installation of more than one unit. 6 mm or more mm or more mm or more 3 mm or more (Service space) 3 mm or more 3 mm or more 3 mm or more 3 mm or more

53 - ( - 3) - 333REFRIGERANT CIRCUIT MODEL: AO GLALL, AO G4LALL, AO G8LALL, AO G4LALA AO G-4LAL AO G-4LAL Refrigerant pipe diameter Liquid : /4" (6.35 mm) Gas : 3/8" (9.5 mm) : AO GLALL /" (.7 mm) : AO G4LALL, AO G8LALL 5/8" (5.88 mm) : AO G4LALA

54 - ( - 4) - 444WIRING DIAGRAMS MODEL: AO GLALL, AO G4LALL, AO G8LALL AO G-4LAL AO G-4LAL

55 - ( - 5) - MODEL: AO G4LALA AO G-4LAL AO G-4LAL

56 - ( - 6) - CAPACITY COMPENSATION RATE FOR PIPE LENGTH 555 AND HEIGHT DIFFERENCE AO G-4LAL This table is created using the maximum capacity. MODEL: AO GLALL Height difference H COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length AO G-4LAL Height difference H HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

57 - ( - 7) - AO G-4LAL This table is created using the maximum capacity. MODEL: AO G4LALL Height difference H COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length AO G-4LAL Height difference H HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

58 - ( - 8) - AO G-4LAL This table is created using the maximum capacity. MODEL: AO G8LALL Height difference H COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length AO G-4LAL Height difference H HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

59 - ( - 9) - AO G-4LAL This table is created using the maximum capacity. MODEL: AO G4LALA Height difference H COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length AO G-4LAL Height difference H HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

60 - ( - ) - 666ADDITIONAL CHARGE CALCULATION MODEL: AO GLALL Refrigerant type R4A AO G-4LAL Refrigerant amount g 5 zrefrigerant charge Total pipe length m 5 or less 5 (MAX) Additional charge g g/m AO G-4LAL MODEL: AO G4LALL, AO G8LALL Refrigerant type R4A Refrigerant amount g 5 zrefrigerant charge Total pipe length m 5 or less 5 (MAX) Additional charge g g/m MODEL: AO G4LALA Refrigerant type R4A Refrigerant amount g 7 zrefrigerant charge Total pipe length m 5 or less 5 3 (MAX) Additional charge g 3 g/m

61 - ( - ) - 777AIRFLOW MODEL: AO GLALL zcooling AO G-4LAL Number of rotations (r.p.m.) 77 Airflow m 3 /h 78 l/s 494 AO G-4LAL CFM 48 zheating Number of rotations (r.p.m.) Airflow m 3 /h 63 7 l/s 453 CFM 959 MODEL: AO G4LALL zcooling Number of rotations (r.p.m.) Airflow m 3 /h 9 8 l/s 53 CFM 4 zheating Number of rotations (r.p.m.) Airflow m 3 /h l/s 483 CFM 4

62 - ( - ) - MODEL: AO G8LALL zcooling AO G-4LAL Number of rotations (r.p.m.) 86 Airflow m 3 /h l/s 556 AO G-4LAL CFM 77 zheating Number of rotations (r.p.m.) Airflow m 3 /h 9 8 l/s 53 CFM 4 MODEL: AO G4LALA zcooling Number of rotations (r.p.m.) Airflow m 3 /h 47 5 l/s 686 CFM 454 zheating Number of rotations (r.p.m.) Airflow m 3 /h 47 5 l/s 686 CFM 454

63 - ( - 3) - 888OPERATION NOISE (SOUND PRESSURE) 88888NOISE LEVEL CURVE MODEL: AO GLALL AO G-4LAL Octave band sound pressure level, db:(db=.µbar) zcooling NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) zheating NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- AO G-4LAL NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz MODEL: AO G4LALL zcooling 8 zheating Octave band sound pressure level, db:(db=.µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz

64 - ( - 4) - MODEL: AO G8LALL AO G-4LAL Octave band sound pressure level, db:(db=.µbar) zcooling NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) zheating NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- AO G-4LAL NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz MODEL: AO G4LALA zcooling 8 zheating Octave band sound pressure level, db:(db=.µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC ,, 4, 8, Octave band center frequency,hz ,, 4, 8, Octave band center frequency,hz

65 - ( - 5) SOUND LEVEL CHECK POINT AO G-4LAL Airflow AO G-4LAL

66 - ( - 6) - 999ELECTRIC CHARACTERISTICS AO G-4LAL Model name AO GLALL AO G4LALL AO G8LALL AO G4LALA Power supply Voltage V 3 ~ Frequency Hz 5 *) Max operating current A Starting Current A Main Fuse (Circuit breaker) *) Wiring Spec. Current A 5 Power Cable mm 4. AO G-4LAL *) The maximum current is the total current of indoor unit and outdoor unit. *) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E5)

67 - ( - 7) - SAFETY DEVICES AO G-4LAL Circuit protection Protection form Current fuse (Near the terminal) Current fuse (Main printed circuit board) Model AO GLALL AO G4LALL AO G8LALL AO G4LALA 5V A 5V 5A 5V 5A 5V 3.5A AO G-4LAL Fan motor protection Thermal protection program OFF : +5 - C ON : C OFF : +5 - C ON : C Compressor protection Terminal protection program (Compressor temp.) Thermal protection program (Discharge temp.) OFF : C ON : After 4 minutes and 8 C or less OFF : C ON : After 7 minutes

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR G24LMLA OUTDOOR AO G24LALA 1. INDOOR UNIT : DTR_AR063E_01 2013.02.28 - (3) - 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AR C72LHTA AR C90LHTA OUTDOOR AO A72LALT AO A90LALT 1. INDOOR UNIT : AR C72LHTA AR C90LHTA DTR_AR061E_03 2013.11.08 1. INDOOR UNIT CONTENTS

More information

6. DUCT TYPE AR 60FUAK, AR 60UUAK

6. DUCT TYPE AR 60FUAK, AR 60UUAK R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor

More information

Wireless R.C. ALL ALL CLASS DC AUYF24LB

Wireless R.C. ALL ALL CLASS DC AUYF24LB Compact Cassette Powerful wide air flow & Quiet operation (18) Optional Compact Outdoor Unit Grille is an option Wireless R.C. For UYF1/14L For UYF18/4LB CLSS LL CLSS LL CLSS UYF1L UYF14L UYF18LB LL CLSS

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL DTW_3SP001E_03 DESIGN & TECHNICAL MANUAL High power series ( 3 phase type ) FUTURE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS 3 PHASE TYPE : WO K112LAT, WO K140LAT, WO

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Compact 4-way Cassette ( ) Type

Compact 4-way Cassette ( ) Type E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

N , Suenaga, Takatsu-ku, Kawasaki , Japan

N , Suenaga, Takatsu-ku, Kawasaki , Japan Multi Air Conditioning System for Buildings Large Multi VRF System DC Inverter Control Compressor Long Piping System Design Efficiency Refrigerant R410A 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER DTV_OAE034E_03--CHAPTER01 2015.01.16 CONTENTS 1. FEATURES... A-01 2. SPECIFICATIONS... A-02 3. ELECTRIC CHARACTERISTICS... A-03 4. DIMENSIONS... A-05 5. REFRIGERANT CIRCUIT...A-11 6. WIRING... A-12 6-1.

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

CASSETTE TYPE AIR CONDITIONER

CASSETTE TYPE AIR CONDITIONER CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz] PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379224 07H050_cover.p65 2007.8.7, 0:27 AM CONTENTS SAFETY PRECAUTIONS... FEATURES

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU ONLY PANASONIC GETS 5 STARS AGAIN, AGAIN & AGAIN AIR CONDITIONING AERO SERIES REVERSE-CYCLE INVERTER Reliability Functionality Ease of use Value for money After sales service Overall customer satisfaction.

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC TECHNICAL CATALOGUE MONO SPLIT RAK-18PSC RAK-25PSC RAK-35PSC RAC-18WSC RAC-25WSC RAC-35WSC HITACHI Specifications in this catalogue are subject to change without prior notice in order for HITACHI to bring

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

4-Way Cassette type. Contents MMU-AP 2H2UL

4-Way Cassette type. Contents MMU-AP 2H2UL E15-3C1 6 Indoor unit MMU-AP 2H2UL 4-Way Cassette type MMU-AP0072H2UL MMU-AP0092H2UL MMU-AP0122H2UL MMU-AP0152H2UL MMU-AP0182H2UL MMU-AP0212H2UL MMU-AP0242H2UL MMU-AP0302H2UL MMU-AP0362H2UL MMU-AP0422H2UL

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

Compact Cassette Type

Compact Cassette Type Compact Cassette Type PART NO.9374379392-04 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 2 NAME OF PARTS... 3 PREPARATORY OPERATION... 4 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER...

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU9RLS ASURLS ASU5RLS AOU9RLSH AOURLSH AOU5RLSH R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed. 1 TECHNICAL CHANGES MUZ09UN MUZ-A09NA MUZ12UN MUZ-A12NA MUH15TN MUZ-A15NA MUH17TN MUZ-A17NA MUH24WN MUZ-A24NA MU15TN MUY-A15NA MU17TN MUY-A17NA MU24WN MUY-A24NA 1. Outdoor unit model has been changed.

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

CONTENTS SAFETY PRECAUTIONS DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS DANGER! CAUTION! 937437936_OM_cover.p65 //08, 3:48 CONTENTS SAFETY PRECAUTIONS... FEATURES AND FUNCTIONS... NAME OF PARTS... PREPARATION... 4 OPERATION... 5 TIMER OPERATION... 7 SLEEP TIMER OPERATION... 8 FILTER LAMP RESET...

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

CONTENTS SAFETY PRECAUTIONS. En-2 DANGER! WARNING! CAUTION! DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-2 DANGER! WARNING! CAUTION! DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... FEATURES AND FUNCTIONS... 3 NAME OF PARTS... 4 PREPARATION... 6 OPERATION... 7 TIMER OPERATION... 9 SLEEP TIMER OPERATION... 0 ADJUSTING THE DIRECTION OF AIR CIRCULATION...

More information

AIR CONDITIONING REVERSE-CYCLE INVERTER

AIR CONDITIONING REVERSE-CYCLE INVERTER AIR CONDITIONING REVERSE-CYCLE INVERTER CLASS LEADING FEATURES FASTER COOLING The new Panasonic Thermal Enhancement Technology (P-TECh) enables the compressor to achieve maximum frequency in the shortest

More information

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4

More information

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

JUNE & 3-4 Head Multi System

JUNE & 3-4 Head Multi System JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G4LFCA AS*G4LFCC AS*G0LFCA AO*G4LFL AO*G4LFCC AO*G0LFT R40A CONTENTS. DESCRIPTION OF EACH

More information

TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series

TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series TECENICAL DATA Order No.AC0902T003V0 Wall mounted Type DC Inverter E-Series Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I 9K 12K 18K 24K 09K 12K 18K WARNING

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

CASSETTE TYPE

CASSETTE TYPE CASSETTE TYPE 9378589032-04 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 2 NAME OF PARTS... 2 PREPARATION... 4 OPERATION... 5 TIMER OPERATION... 7 SLEEP TIMER OPERATION... 8 FILTER INDICATOR

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KS30NKU CS-KS36NKU Product Code No. 852 360 86

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

English AIR CONDITIONER OPERATING MANUAL. Compact Cassette Type Keep this manual for future reference P/N

English AIR CONDITIONER OPERATING MANUAL. Compact Cassette Type Keep this manual for future reference P/N AIR CONDITIONER English OPERATING MANUAL Compact Cassette Type Keep this manual for future reference P/N9374379477-03 OPERATING MANUAL AIR CONDITIONER/INDOOR UNIT/Compact Cassette Type P/N 9374379477-02

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information