1 CLA Aut omat i c Oil/ Gas Heat er s Edit ion GB- 709 Oper at ion Technology Or iginal REM KO Spar e Par ts REM KO - alles bär enst ar k.
2 Oper at ing inst r uct ions Make sure to read these instructions carefully before starting/using the unit! Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes, or maintained incorrectly, etc., or if it is changed without our prior consent. M obile oi l / gas heat er s CLA 25 / 40 / 50 CLA 100 Cont ent s Page Cont ent s Page Safety Hints 3 Installation Requirements 3-4 Waste Gas Pipes 4 Safety Facility 5 Starting 5-6 Shut Down 6 Maintenance 7 Service 7 Drawing CLA 8 List of Spare Parts CLA 9 Technical Data CLA 10 Wiring Diagram 10 Troubleshooting Instructions 11 Always keep these operating instructions near or on the device! 2
3 Saf et y Hi nt s When using this unit make sure always to observe the applicable building- and fire-protection regulations as well as the rules of the trade cooperative association. The unit may be operated only by those persons who have been instructed accordingly. The unit is to be installed and operated in such a way as to ensure that the employees are not endangered by waste gases and radiation heat and that no fire can break out. The unit may only be installed and operated in rooms, when the air-rate fed to the unit is sufficient for combustion. Mobile fuel reservoirs may be installed only when the technical rules for combustible liquids TRBF 210 and 280 are observed. Units without waste gas pipes my be operated only in well aerated rooms. Persons are not allowed to stay permanently in the room where the unit has been installed. Relevant prohibition signs are to be fastened to the entrances. The unit is to be installed only on a non-combustible ground. The unit may not be installed and operated in inflammable and explosive surroundings. A safety zone of 1.5 m around the unit and a minimum distance of 3 m at the unit s waste gas opening are to be observed, even regarding non-combustible objects. The protective air suction lattice is always to be kept free from dirt and loose objects. Make sure not to introduce foreign matters into the unit. Make sure not to expose the unit to direct water jets. All electric cables outside the unit are to be protected from damage (e.g. caused by animals, etc.). Make sure always to pull the mains plug out of the mains socket when maintenance and repairs are carried out. An operation or use other than that indicated in these operating instructions is prohibited! In case of non-observation we will not be held responsible and our guarantee will become void. I nst allat ion Requir e- ment s The heaters may only be installed and operated in compliance with the relevant regulations, especially regulations governing the installation and operation of fireplaces and furnaces. Operators The units may be operated only by persons who have been trained in this field. Installation Install the heaters in a stable position. Install and operate the heaters so as to avoid any hazard to the personnel by fumes and radiation heat, well as to avoid any risk of fire. The heaters may only be installed and operated inside rooms if they are supplied with sufficient air for combustion and if the flue gases escape into the open through flue-pipes. The air supply is sufficient for combustion when, for example, the cubic capacity of a room is at least ten times the nominal thermal load of all heaters in the room, and a natural exchange of air is ensured by means of windows and doors. Heaters without waste gas pipe may be used in rooms, provided that these are well aerated and the percentage of substances which are injurious to health in the breathed in air do not reach inadmissible concentrations. The airing is sufficient when, for example, 1. the room capacity in m³ is at least 30 times the nominal thermal load in kw of all heaters in the room, and a natural exchange of air is ensured by means of windows and doors, or 2. there are air inlet and outlet openings, which cannot be closed, near the ceiling and the ground; the size of which in m² must be at least times the nominal load in kw of all heating devices in the room. Do not install or operate the heaters in rooms or areas exposed to fire or explosion hazards. Room Drying The heaters may be operated in order to dry rooms without evacuating the generated gases through waste gas pipes outside, if the air supplied to those rooms is sufficient for combustion. Persons are not allowed to stay permanently in those rooms. Relevant prohibition signs are to be fixed at the entrances. Test The units are to be tested depending on the operational conditions when necessary, but a least once a year as to their operational reliability. These tests are to be carried out by an expert. 3
4 The burner is to be tested to determine its waste gas values. Supervision The persons charged with the operation of the units have to control the units before starting to work to make sure that there are no visible defects on the control and safety devices and that all the protection devices have been correctly set. If defects are detected, the supervisor is to be informed. If the detected defects jeopardize the unit s operational safety, the unit is to be put out of action. Open-air Installation Heaters operated in the open air must be so installed and protected against atmospheric influence that they do not cause any hazards or inacceptable annoyance. We recommend that a burner cover (REMKO accessories) is used. Installation in closed, well aerated rooms without connection to a chimney The operation of the units is admissible when the minimum air quantity needed for combustion is supplied. A safe exhaustion of the waste gases is to be ensured to exclude inadmissible pollution. Fresh air is fed from below; waste gases are exhausted towards the top. Room Heating Wast e Gas Pipes When the units are operated outside or in open rooms you do not need a waste gas pipe. However, we recommend that you use a waste gas pipe of 1 m length ( see example 2 ) with a rain hood on top of it to prevent the penetration of rainwater and dirt. If the units are used as room heaters, it will be necessary to guide the waste gases outside. The waste gas pipe components are to be laid in such a way as to ensure that a minimum draft of 0.1 mbar is guaranteed. Make absolutely sure not to generate counterpressure by inadequately laid waste gas pipes. Generally a trouble-free operation can be ensured when the waste gas pipes have been laid in an ascending manner and assembled with vertical end pipes. The waste gas pipes must reach at least beyond the eaves but preferrably above the roofridge to avoid counterpressure due to bad weather conditions (e.g. wind). All the waste gas pipe components are to be fastened reliably. Their diameter may not be smaller than that of the unit s waste gas connection piece. A minimum distance of 0.6 m must be kept from inflammable objects. Waste gas components incl. fastening materials can be supplied as accessories. For room heating, hot air generators may only be operated with a room thermostat (accessories). Make sure that sufficient fresh air is fed to ensure perfect combustion. Fresh air is to be fed preferrably through windows and doors or through sufficiently dimensioned openings in the outer wall. Attention! Avoid under- or overpressure in the room where the unit is installed, as this would result in combustion troubles. Please make absolutely sure that the suction and outgoing air opening is adapted to the fan power concerned (see rating plate). If this is not possible, the burner has to be equipped with a separate air supply device to ensure perfect combus-tion. Safety Distances Make sure to observe the following safety distances to ensure a safe operation of the unit: - towards the top, without waste gas pipe 3,0 m - towards the top, fire-retarding ceiling 1.5 m - towards the sides, non-burning objects 0.6 m - blow-off side, non-burning objects 3.0 m - suction side, for perfect air supply 1.0 m The floor and the ceiling must be from fire-retarding materials. Suction and blow-off cross sections may not be reduced. Hint! Example 1 Heater with waste gas pipe leading outside. Example 2 Heater without waste gas pipe leading outside. Example 3 Inadmissible arrangement; see hint. Make sure that the waste gas pipes are correctly installed with a condensate trap (see example 1), to avoid damage to the combustion chamber through humidity deposits (condensate) (see example 3). 4
5 Saf et y Faci l i t y St ar t ing Triple combination control according to DIN 3440 The device has 3 functions: 1. Fan Control (TR) The tripping point is set with the adjusting lever (fan). Rated value approx. 35 to 40 C. 2. Burner Temperature Monitor (TW) The tripping point is set with the adjusting lever (burner). Rated value approx. 110 to 115 C. 3. Safety Temperature Limiter (STB) The tripping point is fixed according to DIN After tripping, a burner restart is prevented. The reset button is operated from outside. Before a reset, check the operating conditions of the device to ensure that the STBtemperature is not exceeded again. TR Switching lever Switching Lever "AUTO" Automatic control of the air supply fan via fan control (TR) depending on the temperature of the air. "MAN" The fan works independent of the temperature of the air and can be used for continuous ventilation. Note! The device is equipped with a sensor monitoring feature and is cold-resistant down to -20 C; below -20 C the device switches off; when the temperature rises above this temperature, it switches on again. When the sensor or the capillary tube is damaged, or when an overtemperature of approximately 220 C is reached, the filling medium is emptied and the device performs a safety switch-off operation. The device is no longer operable and must be replaced. When the safety facility has to be replaced, take care not to damage or excessively bend the capillary tubes. Use only the original spare part, reference no Do not bend the sensor spirals near to solder points. When mounting, the sensor spirals may not be damaged or bended sharply edged. The sensors must be fixed in the mounting brackets provided by the factory. The sensors must always be free from dust and dirt. STB TW Make sure to charge a person with the operation and supervision of the unit who has been instructed sufficiently regarding the handlings concerned. Prior to starting, the unit is to be checked to make sure that there are no visible defects on the control and safety devices, that the unit has been installed correctly and that it has been properly connected to the mains. Install unit in a stable position. Make sure that air is supplied for combustion. Make sure that the air can be sucked in and be exhausted freely. Avoid overpressure and underpressure in the room where the unit has been installed. Make sure that enough fuel is supplied. (only use clean fuel oil EL and diesel, respectively) Attention! A sufficient quantity of free-flowing fuel oil must be available even with low outside temperatures. Paraffine formation can start even at a temperature of 5 C. Adequate measures are to be taken to avoid this. Hint! Any additional clauses of the relevant building regulations and technical rules for combustible liquids (TRBF 210 and 280 ) are to be observed. The waste gas values of the oil- or gas-burner are to be checked and adjusted properly by authorized experts in accordance with the local conditions. Connection to the Mains The units are operated with alternating current of 230 V. Connection to the mains is carried out by means of an installed mains cable with earthing-contact plug. Possibly required extension cables must be selected according to the existing cable length, the unit s connecting line and the intended purpose. All extension cables are to be used only after having been removed from the roller. 1 Put operating switch (1) into 0 position ( = OFF). Do not jumper or obstruct the safety features while the heater is in operation! 5
6 Connect unit plug (2) to a suitable mains socket (230V/1 ~ 50Hz). Heating Without Room Thermostat The unit runs in continuous operation. Plug the supplied bridge circuit plug (3) into the thermostat socket (4) of the switch box. Put the operating switch (1) into 1 position. Fully Automatic Heating With Room Thermostat Remove the bridge circuit plug (3). Plug thermostat plug (5) of the room thermostat (accessories) into the thermostat socket (4) of switch box. Hot Air Distribution All the units are equipped with silent and nearly maintenance-free axial fans. Hot air may be distributed only in accordance with the fan capacity of the units concerned. The possible hose/pipe lengths depend on the resistance on the air side of the used air ducts. Air is preferrably distributed through pipings or special hot air and sheet hoses, respectively. Please observe the following instructions when hot air hoses are to be fitted: Please use exclusively those hot air hoses (accessories) which have been approved by our company. The inside overlappings on the seams of the hot air hoses must run with the air current direction. Make sure that the hoses and pipes, respectively, are safely fastened to the unit s outgoing air connection piece. The pipes and hoses may not have sharp kinks and bends in order to avoid heat accumulation. In the case of increased suction temperatures or resis-tance on the unit s outgoing air side, the burner can be switched off by the temperature controller (TW) during the heating operation for a short time. When the temperature has fallen the burner is restarted automatically. 6 Put room thermostat (6) in a suitable place. The thermostat feeler may not be exposed directly to the hot air current. Preselect desired room temperature on the room thermostat (accessories). While the unit is operating, frequent startings of the burner should be avoided. When the temperature is too high on the unit s outgoing air side, the heating-operation is interrupted automatically for a longer period by the STB! Shut dow n 1 Put the operating switch (1) into 1 position. 1 Attention! Put operating switch (1) into 0 position. ( = OFF) Close fuel supply. 6 The unit runs fully automatically with the temperature which has been preselected on the room thermostat. Hint! When the oil burner has been installed by our works, the heater is equipped with a the standard oil preheating. The fan continues running to cool down the combustion chamber and then stops later. Never interrupt the connection to the mains before the end of the whole after-cooling phase (except in emergency situations). The fan can start several times before final switching off! Our guarantee does not cover damages caused to the unit by overheating! The connection to the mains of the units is to be carried out in accordance with the VDE 0100 regulations to a special supply point with protection device against faulty current.
7 M ai nt enance The unit is to be maintained regularly whereby some fundamental rules are to be observed to ensure a long service life and trouble-free operation. Use a clean slightly humid cloth for cleaning and wiping the dirt off the surface. In case of obstinate dirt only suitable cleaning agents should be used. Prior to starting any work make sure to pull the mains plug out of the mains socket! The unit is to be kept free from dust and other deposits and is to be cleaned only with a dry or humid cloth (do not use water jet). Do not use any aggressive cleaning agents or those which are harmful or environmentally unfriendly. Do not use cleaning agents which contain solvents. Use only clean fuel oil EL and diesel, respectively (make sure to avoid paraffine formation). Check oil filters or gas filters regularly and replace dirty filters. Check whether the unit is free from mechanical damage, if not, replace faulty parts. Check fan wings and combustion chamber with heat exchanger in regular intervals and clean them when they are dirty. Check oil tank regularly and clean it when necessary to remove dirt and foreign matters. Make sure that the waste gas and combustion air can be always evacuated properly. Check safety devices regularly. The unit is to be maintained and cleaned in regular intervals. Keep feelers of triple combination control always free from dust and dirt. Have the waste gas values of the oil or gas burner checked regularly by authorized experts. For safety reasons we recommend that you conclude a maintenance contract! Make sure to store the unit in a dust-free and dry place when it is not used for a longer period. Ser vice The complete unit including heat exchanger, combustion chamber and oil burner is to be cleaned from dust and dirt after every heating period, or even earlier, depending on the operational conditions. Expendable parts, such as flue gas suppressors, gaskets, oil filter inserts, and oil nozzles are to be checked and replaced, if necessary. Heat Exchanger Cleaning Cut unit from the mains Disassemble connection piece for outgoing air (only CLA 25/40/50) In addition CLA 100: - disassemble jack ring (pos. 14) - disassemble cover plate (pos. 1) - disassemble upper insulation (pos. 12) Remove revision cover (pos. 22) Pull flue gas suppressor (pos. 22) out of unit Clean flue gas passes. Special cleaning brushes can be obtained as accessories. Clean flue gas suppressor or replace them, if necessary. Check gaskets and revision cover and replace, if necessary. Assembly is to be carried out in reverse order, where-by you should make sure that the gaskets and the revision cover is correctly seated. Combustion Chamber Cleaning Cut unit from the mains Remove burner Clean combustion chamber through its opening by means of a vacuum cleaner. Special cleaning sets can be obtained as accessories to the REMKO industrial vacuum cleaner. Install burner; check flange gasket and replace, if necesary. Make sure that the burner is exclusively maintained by authorized experts. Make sure to observe the limit values for waste gas losses according to the regulations for small-sized fireplaces. Setting and maintenance is to be carried out only by authorized experts! 7
8 CLA 25/ 40/ 50 CLA We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
9 Li st of spar e par t s CLA Fig.-No. description CLA 25 CLA 40 CLA 50 CLA 100 EDV-Nr. EDV-Nr. EDV-Nr. EDV-Nr. 1 base plate 2 side cover - left/right 3 insulation - right 4 insulation - left 5 insulation 6 insulation 7 insulation 8 blow-out side 9 blow-out cone 10 inlet side 11 cover plate 12 insulation - top 13 rosette for exhaust connection 14 crane eye 15 wheel 16 wheel lock ring 17 wheel cap 18 axle 19 support base 20 combustion chamber with heat-exchanger, cpl. 21 waste gas suppressor 22 inspection cover 23 seal for inspection cover 24 transport handle 25 fan 26 capacitor 27 switch box, cpl. 28 operating switch 29 thermostat socket - angled 30 bridge circuit plug 31 thermostat plug (accessories) 32 triple combination control 39 hose nipple 40 fitting for oil-reservoir 41 hose clamp 42 fuel filter with shut-off valve (2 lines) 43 filter element (felt) 44 oil filter cup 45 O-ring seal n. shown plug to burner mounting angle for fuel filter connecting cable with plug connecting nut for crane eye exhaust connection, loose When ordering spare parts please indicate EDV-No. and machine no. (see typeplate)! 9
10 Technical Data Series CLA 25 CLA 40 CLA 50 CLA 100 rated heat power max. kw ratedheat output kw 26, rated air output m³/h fuel heating oil EL or liquid gas fuel consumption, max. kg/h 2,6 3,0 5,0 9,0 nozzle (Steinen) 2) USG/ S 0,65/60 0,75/60 1,25/60 2,25/60 pump-pressure (mit ÖV) 2) bar flue gas loss % 9, electrical connection 1~ V frequency Hz rated current A 1,95 1,95 3,3 4,7 power take-up kw 0,4 0,4 0,7 1,0 capacitor (fan) µf fuse protection (required) A sound pressure level L pa 1m 1) db(a) air outlet Ø mm waste gas connection Ø mm weight (without burner) kg dimensions: length, total mm width, total mm hight, total mm ) noise measuring (without burner) DIN KL 3 Dimensions and specifications subject to change 2) The mentionend nozzle-sizes and pump-pressures result from coordination tests on the test bench. The fuel consumption had been measured out. On account of tolerances and oil-temperature these specifications must be considered as guiding values. Wi r i ng Di agr am S = operating switch KL = terminal strip SK = switch box, cpl. C = capacitor (CLA 100: capacitor in terminal box of fan) RT = room thermostat socket M = fan motor TR = fan control thermostat STB = safety temperature limiter TW = burner temperature monitor KB = triple combination control, cpl. WS = plug to burner, 7 poles (only if burner has been installed by our works) blau = blue braun = brown schwarz = black 10
11 Tr oubleshoot ing Inst r uct ions Unit does not start: Check connection to the mains Check safety thermostat (STB) Put operating switch into I position Check whether bridge circuit plug has been plugged in correctly Check room thermostat and its plug, respectively. The temperature set at the room thermostat must be higher than the room temperature. Set change lever of triple combined regulator to MAN position. When the fan starts running the fault is to be eliminated in the burner area. Burner does not start: Check whether fuel filter is dirty Open stop valve of fuel filter Check whether the fuel quantity in the reservoir is still sufficient Check whether paraffine has been formed in the filter and fuel (this can happen even at 5 C) Check whether oil hoses have been damaged (air suction, air bubbles) Check safety temperature limiter (STB); if the STB has been released make sure to find the reasons why, e.g.: unit could not cool down, as the electric power has been cut off temperature of blown out air too high because of inadequate air guidance no free air inlet and outlet Check temperature controller (TW) in the triple combined regulator (by bridging) Check whether the feeler or capillary tube of the triple combined regulator has been damaged (see description safety device ). Check whether the interference lamp of burner relay has been lit up; if so, unlock relay by pressing the anti-interference button. The burner tries to start (take delayed burner start due to oil preheating into account). Attention! If the burner is switched off once more after the starting phase because of a fault, another unlocking may not be carried out before a waiting time of 5 minutes has lapsed. Make sure to avoid any further unlocking (danger of deflagration). For safety reasons all repairs and maintenance work regarding the burner is to be carried out only by authorized experts. Fan Does not Start: Check whether fan wing is freely running Check whether electric cable of fan has been damaged Check operating capacitor of fan Check fan regulator (TR) in the triple combined regulator (by bridging). Attention! Repairs regarding the electric installations may be carried out only by authorized electricians! During the unit s operation safety devices may neither be bridged nor blocked! If all the controls regarding the different functions have been carried out without a result, you should contact an authorized service center. Important Hint! An operation/use other than that indicated in these instructions is prohibited! In the case of non-observation we will not be held responsible and our guarantee will become void. Any claims under guarantee regarding materials can be accepted only when the orderer or his customer has filled in completely the guarantee certificate which is enclosed with every REMKO-heater and has returned it to REMKO GmbH & Co. KG in due time after the unit s sale and commissioning. 11
12 REMKO GmbH & Co. KG Klima- und Wärmetechnik D Lage Im Seelenkamp 12 D Lage Postfach 1827 Telefon ( ) Telefax ( )
REMKO CLK Mobile automatic heater
REMKO CLK Mobile automatic heater Operation Technology Spare Parts Edition GB M04 REMKO - powerful like a bear. Operating Instructions Read these instructions carefully before setting up/operating the
More informationPropane Heater REMKO PGM 30 REMKO PGM 60
Propane Heater REMKO PGM 30 REMKO PGM 60 Operation Technology Spare Parts Edition GB L07 REMKO strong as a bear. Operating instructions Make sure to read these instructions carefully before starting/using
More informationREMKO CLK 20 Mobile Heaters
REMKO CLK 20 Mobile Heaters Operation Technology Spare Parts Edition GB M08 REMKO powerful like a bear Operating Instructions Before commissioning/use of the equipment, these operating instructions must
More informationIDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80
IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...
More informationREMKO CLK CLK 30, CLK 50, CLK 70, CLK 120, CLK 150
REMKO CLK CLK 30, CLK 50, CLK 70, CLK 120, CLK 150 Automatic oil/gas heaters Operation Technology Spare parts Edition GB I12 Contents Safety notes 4 Unit description 4 Specifications for fan-assisted
More informationREMKO AMT 60-E - 90-E Mobile Dehumidifier
REMKO AMT 60-E - 90-E Mobile Dehumidifier Operation Technology Spare Parts Edition GB M02 REMKO powerful like a bear. Operating Instructions Make sure to read these instructions carefully before starting/using
More informationDH-Direct Fired Poultry Farm Diesel Heater
DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or
More information1. GENERAL SAFETY RULES
ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance
More informationOperating instructions
Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen
More informationHeating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL
Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationOil burners Brûleurs fioul Stookoliebranders
Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement
More informationREMKO DZH. Oil Heaters. Operation Technology Spare Parts. Edition GB D04
REMKO DZH Oil Heaters Operation Technology Spare Parts Edition GB D04 Contents Safety Notices 4 Device Description 4 Mounting Regulations 5 Commissioning 6 Shutdown 7 Maintenance and Care 8 Trouble Shooting
More informationParts Available from
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
More informationINLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL
INLINE CENTRIFUGAL FAN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery
More informationInstallation and maintenance manual
Installation and maintenance manual Warm air heater WS/WO (Copy of the original version) Wolf GmbH D-84048 Mainburg Postfach 1380 Telefon +498751/74-0 Telefax +498751/741600 Internet: www.wolf-heiztechnik.de
More informationINLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL
INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data
More informationSpecifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1
Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)
More informationAXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL
TUBO-M/MZ AXIS-QA AXIS-Q TUBO-F AXIS-QR AXIS-F AXIS-QRA AXIS-QA G AXIAL FANS EN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationINSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S
INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S RS-600 (CHS60SS)-GB-05.indd 1 6/8/2010 9:30:59 AM TABLE OF CONTENTS 1. Introduction 2 2. Safety precaution 2 3. Intended use 3 4. Parts supplied 3
More informationOperation Manual. Trash Water Pump ARTICLE Image similar
Operation Manual Trash Water Pump ARTICLE 50781 Image similar Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further
More informationCODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80
Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical
More informationOperating Instructions
Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationJUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS
JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods
More informationinfrared paraffin / kerosene / diesel heater
instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
More informationSilent TS. Nr / Ideas for dental technology / A. Made in Germany
Silent TS Nr. 2921-0050 / 2921-1050 21-9191 30102012 / A Made in Germany Ideas for dental technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Silent TS Nr. 2921-0050
More informationFundamental safety warnings
INTRODUCTION Read these instructions carefully before using the appliance. Failure to follow these instructions may result in injuries and equipment damage. The manufacturer is not liable for damages resulting
More informationSilencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter
VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)
More informationHG 675 CX 60 HG 675 CN 60 HG 675 CW 60
HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,
More informationThermo 230 / 231 / 300 / 301 / Troubleshooting
Thermo 230 / 231 / 300 / 301 / 350 5 Troubleshooting 5 Troubleshooting 5.1 General This section describes troubleshooting procedures for the heaters Thermo 230, 231, 300, 301 and 350. CAUTION Troubleshooting
More informationHEAT RECOVERY AIR HANDLING UNIT
HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty
More informationK Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.
K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............
More informationINFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP
InstructioNS for: INFRARED PARAFfIN / KEROSENE / diesel HEATER model No: ir20.v2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these
More informationNEPTUN I Sole cleaning unit Art.-No.:
Assembly and operating instructions Please read the instruction carefully before assembling and putting into operation. Keep instruction for future reference. Contents. General 2. Function 3. Installation
More informationOperating Instructions
WD 3 Premium Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. English 5 59658050 (08/15) 10 11 12 13 14 15 16 2 3 4 Contents General
More informationmodel No: ir20.v2 FUSE
InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
More informationORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L
ORIGINAL OPERATING INSTRUCTIONS 02-11 ASH VACUUM CLEANER / 18L IMPORTANT! SAFETY INSTRUCTIONS When using the appliance, a few safety precautions must be observed to avoid injuries and damage. Please read
More informationVIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit
Service instructions for contractors VIESMANN Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit VITOLADENS 300-T 1/2007 Please keep safe. Safety instructions Safety instructions
More informationbreeze easytm model # F100-1W
DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain
More informationDF400/DF600. Construction Heaters. Installation and Maintenance Manual
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction
More informationPV3000S Professional Pond Vacuum
PV3000S Professional Pond Vacuum INSTRUCTION MANUAL PV3000S Professional Pond Vacuum PV3000S POWER CONSUMPTION POWER SUPPLY NOMINAL CURRENT POWER CABLE LENGTH MAX PUMPING CAPACITY MAX PUMPING HEAD AUTOMATIC
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More informationWET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS
WET & DRY GARAGE VAC 20L CAPACITY 1.5M SUCTION HOSE STAINLESS STEEL TANK ON BOARD ACCESSORY STORAGE 1250 WATT MOTOR KP702 Table of Contents 20L WET & DRY GARAGE VAC Know Your Product...1 Vacuum Safety
More informationAirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Operating manual List of contents, Operating manual Page 1. General information... 02 2. Device description... 03 3. Adjustment
More informationInstruction manual ASPIMAX 16
Manufacturer: deconta GmbH Im Geer 20, 46419 Isselburg Type-No.: 530 ( / 400) 540 ( / 230) Serial-No.: Table of contents on page 1 Basic safety advice 3 2 Technical description 4 2.1 Functionality Filter
More informationInfrared Diesel Heater
Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the
More informationINSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700
A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,
More informationInstallation and operating instructions. DK energy storage and DK energy buffer
Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The
More informationMOBILE HOT AIR HEATING SYSTEMS
MOBILE HOT AIR HEATING SYSTEMS Issue 2012 Mobile hot air heating systems Mobile Heaters Heating Centers Quality with systems RAPID HEAT ADAPTED TO YOUR NEEDS Hot air heating systems for air, to feel good,
More informationMillo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A
Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...
More informationCENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL
CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements
More informationOperating Instructions
Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72
More informationDIESEL/PARAFFIN HEATERS
DIESEL/PARAFFIN HEATERS MODEL NO: XR80, XR110, XR160, XR210 PART NO: 6931004, 6931006, 6931008, 6931012 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE product.
More informationKKKKKKKCOOKER HOOD INSTRUCTION MANUAL
KKKKKKKCOOKER HOOD INSTRUCTION MANUAL Read this manual carefully before operation Pictures in this manual are for reference only, the product in kind prevail. E60MEW2M19 Contents 01 02 03 04 05 06 07 08
More informationUSER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING
USER S MANUAL VCU/ Series CENTRIFUGAL FAN IN SCROLL CASING 2 CONTENTS Introduction Use Delivery set Designation key Technical data Safety requirements Design and operating logic Mounting and set-up Connection
More informationOperating Manual JuniorPower
To be read completely before start-up! Operating Manual JuniorPower 12/04 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek Tel. +49 40 604110 Fax +49 40 6041149 www.oertzen-gmbh.de info@oertzen-gmbh.de
More informationMODEL 466 Radiant / Convector Gas Fire Black Beauty
O W N E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep
More informationINSTALLATION AND MANINTENANCE INSTRUCTIONS
INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional
More informationMV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.
MV 4 MV 4 Premium Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651790 10/13 3 4 2 5 6 7 1 8
More informationSIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A
cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors
More informationInstructions Manual SHC520X - SHC700X
Instructions Manual SHC520X - SHC700X INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for
More informationBIX B-One 100 kw INSTALLATION GUIDE
BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.
More information2 000W CYCLONIC BAGLESS VACUUM
2 000W CYCLONIC BAGLESS VACUUM /GVAVK08 Instruction Manual Contents Guide to the Appliance Caring for the Environment Safety Information and Warnings Basic Set Up Care and Maintenance Troubleshooting 2
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationWATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2
I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationInstallation, operation and care. Pellmax UB. Burner not included Replaces:
Installation, operation and care Burner not included 2011-11-11 ver: Replaces: Contents 11.11 otes...3 General...4 Function...4 Technical data...5 System principle Pellmax with radiator and tank-in-tank
More informationLFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR
7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or
More informationDS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.
DS 5.600 English.... 5 Français... 11 Español... 17 CONSUMO DE ENERGIA 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.600 59634180 (04/12) 2 3 4 Dear Customer, Please read and comply
More informationCONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling
CONTENTS 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling 6. Installation 6.1 Plates 6.2 Dimensions 6.3 Location 6.4 Free room 6.5 Installation
More informationREMKO ETF 220 Portable Air Dehumidifier
REMKO ETF 220 Portable Air Dehumidifier Operation Technology Spare Parts Edition GB P04 REMKO powerful like a bear. Operating Instructions Read these instructions carefully before setting up/operating
More informationTHERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS
THERMOFILM CONVECTIVE PANEL HEATER Rev C JUL13 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS 1. Important Safety Instructions 2. Specification
More informationREMKO ETF 240 Portable Air Dehumidifier
REMKO ETF 240 Portable Air Dehumidifier Operation Technology Spare Parts Edition GB P10 REMKO powerful like a bear. Operating Instructions Read these instructions carefully before setting up/operating
More informationTECHNICAL INSTRUCTIONS USE AND MAINTENANCE
TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set For boilers CentroPlus 25/35 and CentroPlus-B 25/35 (solid fuel and wood pellets fuel firing) TUPSCP-K-11-2016-ENG CONTENTS 1.Introduction 2. Status
More informationTechnical information. Remeha P200. Pressurized boiler. Heat output: kw
Technical information Remeha P200 R e m e h a P 2 0 0 Pressurized boiler Heat output: 59-256 kw Remeha P 200 CONTENTS Preface 3 1. Description of the unit 4 1.1 General 4 1.2 Burners 4 2. Construction
More informationOperating Instructions
Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. 5.962-066.0 02/07 Dear Customer, Please read and comply with these instructions prior
More information15 20 kw kw kw
Burner Set-up Details 15 20 kw 20 26 kw 29 36 kw Riello RDB2 Please read these instructions carefully before commissioning and using this appliance. To be retained by the householder HEALTH AND SAFETY
More informationATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL
STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION
More informationSupply air unit VEKA Installation & Maintenance
November 2008 Safety instructions Operating the air treatment unit and accessory components WARNING Before the air treatment unit is taken into service, any free connections must be provided with protective
More informationOperating Instructions
Operating Instructions TEKA Cartmaster Type PF-W 1, PF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0)
More informationPATRON CLIMAT OIL FIRED CONSTRUCTION HEATERS MODELS 40, 50 AND 130 OWNER S MANUAL. HEATER SIZES 135,000 and 195,000 and 570,000 BTU/Hr
PATRON CLIMAT OIL FIRED CONSTRUCTION HEATERS MODELS 40, 50 AND 30 OWNER S MANUAL HEATER SIZES 35,000 and 95,000 and 570,000 BTU/Hr GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS
More informationREMKO AMT 45-E to 115-E
REMKO AMT 45-E to 115-E Air dehumidifiers Operation Technology Spare parts Edition GB D09 Contents Air dehumidification 4 Safety notes 6 Intended use 7 Customer service and guarantee 7 Environmental protection
More information2245 Wyecroft Road #5, Oakville, Ontario Canada L6L 5L7 Ph: Toll Free: Fax:
2245 Wyecroft Road #5, Oakville, Ontario Canada L6L 5L7 Ph: 905-827-6157 Toll Free: 1-877-427-2266 Fax: 905-827-2027 Instructions for Installation, Operation & Service Manufacturer: Zero Appliances, Chloorkop
More informationUser s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )
www.windsterhood.com User s Manual LINER SERIES WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 ) NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON
More informationINSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB) Pag. 1 Fig - Fig. - Abb.- Fig.- Fig.- Фиг.- Obr.- Fig.- Εικ. - Joonis - Kuva - Sl. -.ábra - Fig. -.att. - Afbeelding - Fig. - Rys.- Fig.- Fig. - Схема
More informationhp Dust Collector With Vacuum Attachment
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationOPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25
OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 NOT FOR DOMESTIC USE SPACE HEATING ONLY Made By: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia
More informationInstallation manual Mini Comfort 50 S/L 07/ V EN
Installation manual Mini Comfort 50 S/L 07/2015 - V 1.1 - EN www.veneco-ventilation.be Veneco ventilation by Elek Trends Productions nv Blauwfazantjesstraat 4 B - 7700 Moeskroen Tel. +32 (0)56 48 15 90
More informationElectronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions
Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview
More informationTROUBLESHOOTING VANGUARD
TROUBLESHOOTING VANGUARD IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring. WARNING: Disconnect electrical power to the Unit to prevent personal injury
More informationCOOKER HOOD. AFTER-SALES SERVICE (Including Spare Part Request)
TM AFTER-SALES SERVICE (Including Spare Part Request) 1800-282-093 603-6286 9000 www.rubine.com.my WARRANTY: Standard 1-year warranty on manufacturing defects. 5-year warranty on cooking hood motor. PRODUCT
More informationPar 16 with GU10 Socket
User manual Par 16 with GU10 Socket Table of contents 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 2. Technical Data... 4 3. Description... 4 3.1. Introduction... 4 3.2. Safety
More informationInstructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine
GB IT FR DE TR Instructions for use and installation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube
More informationTurbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.
OWNER S MANUAL Model EP600 120V., 60Hz., 7.5 Amps. Turbo Stick Vac For information or assistance: EURO-PRO Operating LLC 94 Main Mill Street, Door 16 Plattsburgh, NY 12901 Tel.: 1 866 98SHARK (74275) www.sharkvac.com
More informationTTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN
TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating
More informationOperating instructions. Web Cleaner 1 / 2. Air Line
Operating instructions Web Cleaner 1 / 2 Air Line page 2 Operating instructions for Web Cleaner 1 Web Cleaner 2 Contents 1 Product description... 5 1.1 Application... 5 1.2 Function principle... 5 1.3
More informationPart No KEMPER Filter-Master XL
Part No. 150 0492 KEMPER Filter-Master XL 1. Application and Mode of Operation.... 2 2. Safety Instructions......... 2 3. Placing into Operation...... 3 4. Operation Elements and Function... 3-4 5. Installation
More informationPLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual
PLEASEREADANDSAVETHESEINSTRUCTIONS NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE IT ON A FLAT,
More information